ARTEM-COMPOINT-BLD-MIB

File: ARTEM-COMPOINT-BLD-MIB.mib (7190 bytes)

Imported modules

RFC1213-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

ifIndex OBJECT-GROUP NOTIFICATION-GROUP
enterprises IpAddress Integer32
OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY
NOTIFICATION-TYPE TruthValue MacAddress
RowStatus TEXTUAL-CONVENTION

Defined Types

ArtemBLDIfEntry  
SEQUENCE    
  artemBLDIfRowStatus RowStatus

Defined Values

artem 1.3.6.1.4.1.4280
Funkwerk Enterprise Communications MIB file that provides additional attributes not covered by standard MIBs for Broken Link Detection in artem products.
MODULE-IDENTITY    

artemBLD 1.3.6.1.4.1.4280.6
Definitions and attributes for Broken Link Detection.
Status: current Access: read-write
OBJECT-IDENTITY    

artemBLDAdminStatus 1.3.6.1.4.1.4280.6.1
This attribute selects whether periodic BLD link checking is administratively enabled.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

artemBLDLinkState 1.3.6.1.4.1.4280.6.2
This attribute indicates whether the IP target monitored by BLD is currently reachable.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

artemBLDTargetAddress 1.3.6.1.4.1.4280.6.3
This attribute holds the IP address of the connection target which is periodically checked by BLD.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

artemBLDTargetIf 1.3.6.1.4.1.4280.6.4
This attribute hold the ifIndex of the interface that received the most recent reply from the BLD target. The value 0 indicates that no reply has been received.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

artemBLDCheckInterval 1.3.6.1.4.1.4280.6.5
This is the interval between successive checks whether the BLD target is reachable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..3600  

artemBLDTimeout 1.3.6.1.4.1.4280.6.6
This attribute defines the timeout for replies from the BLD target.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..300  

artemBLDRetries 1.3.6.1.4.1.4280.6.7
This attribute defines the number of timer BLD retries to reach the target after an initial failed attempt until the connection is considered broken.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..99  

artemBLDIfTable 1.3.6.1.4.1.4280.6.8
This is table of all interfaces which will be modified when BLD detects that its target is unreachable. AP type interfaces are temporarily closed and will not allow any client to associate. Bridge type interfaces are unlocked if their operational status is disabled(2).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ArtemBLDIfEntry

artemBLDIfEntry 1.3.6.1.4.1.4280.6.8.1
An entry in artemBLDIfTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ArtemBLDIfEntry  

artemBLDIfRowStatus 1.3.6.1.4.1.4280.6.8.1.1
Auxiliary variable for creation of new object instances and/or the deletion of existing object instances.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

artemBLDNotification 1.3.6.1.4.1.4280.6.9
OBJECT IDENTIFIER    

artemBLDConnection 1.3.6.1.4.1.4280.6.9.1
This notification is triggered for every interface in artemBLDIfTable whenever BLD detects a change in target link state.
Status: current Access: read-create
NOTIFICATION-TYPE    

artemBLDGroup 1.3.6.1.4.1.4280.6.10
Attributes for artem Broken Link Detection (BLD).
Status: current Access: read-create
OBJECT-GROUP    

artemBLDNotificationGroup 1.3.6.1.4.1.4280.6.11
Notifications for BLD events
Status: current Access: read-create
NOTIFICATION-GROUP