ARRIS-D5-ENT-SENSOR-THRESH-MIB

File: ARRIS-D5-ENT-SENSOR-THRESH-MIB.mib (5064 bytes)

Imported modules

ARRIS-MIB ENTITY-MIB ENTITY-SENSOR-MIB
SNMPv2-CONF SNMPv2-SMI

Imported symbols

packetport cm110 tcm
ttm ttp cmtsMSAS
cmts1500 cmtsC3 cmtsC4
cmtsCommon mrcController arrisGlobalAccessMib
arrisGlobalAccessProductUas arrisD5UEQam entPhysicalIndex
entityPhysicalGroup entPhySensorType entPhySensorScale
entPhySensorPrecision entPhySensorValue entPhySensorOperStatus
entPhySensorUnitsDisplay entPhySensorValueTimeStamp entPhySensorValueUpdateRate
entitySensorCompliance entitySensorValueGroup entPhySensorEntry
OBJECT-GROUP MODULE-COMPLIANCE Integer32
OBJECT-TYPE MODULE-IDENTITY

Defined Types

EntThreshEntry  
SEQUENCE    
  entLowerWarnThresh Integer32
  entUpperWarnThresh Integer32
  entLowerFatalThresh Integer32
  entUpperFatalThresh Integer32

Defined Values

arrisEntSensorThreshMIB 1.3.6.1.4.1.4115.1.8.1.4
This is the extension Module to rfc3433 ENTITY-SENSOR-MIB.
MODULE-IDENTITY    

entThreshObjects 1.3.6.1.4.1.4115.1.8.1.4.1
OBJECT IDENTIFIER    

entThreshTable 1.3.6.1.4.1.4115.1.8.1.4.1.1
This table contains one row per physical sensor. Each row contains the set of thresholds maintained for each pyhsical sensor.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EntThreshEntry

entThreshEntry 1.3.6.1.4.1.4115.1.8.1.4.1.1.1
The threshold information for a particular physical sensor. An entry in this table describes the upper and lower warning thresholds, as well as the upper and lower fatal thresholds.
Status: current Access: not-accessible
OBJECT-TYPE    
  EntThreshEntry  

entLowerWarnThresh 1.3.6.1.4.1.4115.1.8.1.4.1.1.1.1
The lower warning threshold for a physical sensor. When a sensor value goes below this threshold, the system will continue to operate, but the craftperson should evaluate the problem.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

entUpperWarnThresh 1.3.6.1.4.1.4115.1.8.1.4.1.1.1.2
The upper warning threshold for a physical sensor. When a sensor value goes above this threshold, the system will continue to operate, but the craftperson should evaluate the problem.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

entLowerFatalThresh 1.3.6.1.4.1.4115.1.8.1.4.1.1.1.3
The lower fatal threshold for a physical sensor. When a sensor value goes below this threshold, the system will shutdown.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

entUpperFatalThresh 1.3.6.1.4.1.4115.1.8.1.4.1.1.1.4
The upper fatal threshold for a physical sensor. When a sensor value goes above this threshold, the system will shutdown.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

entThreshConformance 1.3.6.1.4.1.4115.1.8.1.4.2
OBJECT IDENTIFIER    

entThreshCompliances 1.3.6.1.4.1.4115.1.8.1.4.2.1
OBJECT IDENTIFIER    

entThreshCompliance 1.3.6.1.4.1.4115.1.8.1.4.2.1.1
Description.
Status: current Access: read-write
MODULE-COMPLIANCE    

entThreshGroups 1.3.6.1.4.1.4115.1.8.1.4.2.2
OBJECT IDENTIFIER    

entThreshValueGroup 1.3.6.1.4.1.4115.1.8.1.4.2.2.1
Description.
Status: current Access: read-write
OBJECT-GROUP