ANS-TRAPS-MIB
File:
ANS-TRAPS-MIB.mib (51040 bytes)
Imported modules
Imported symbols
Defined Values
traps |
1.3.6.1.4.1.193.96.115.7 |
OBJECT IDENTIFIER |
|
|
|
ansIdentifier |
1.3.6.1.4.1.193.96.115.7.1 |
A reference to the affected entity. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RowPointer |
|
|
alarmingObject |
1.3.6.1.4.1.193.96.115.7.11 |
The alarming object. Identifies either a variable in
the group of variables belonging to the alarming object,
or a row in a table representing the alarming object. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
InstancePointer |
|
|
alarmType |
1.3.6.1.4.1.193.96.115.7.12 |
The type of the alarm. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AlarmType |
|
|
alarmSeverity |
1.3.6.1.4.1.193.96.115.7.13 |
The perceived severity of the fault. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AlarmSeverity |
|
|
alarmTime |
1.3.6.1.4.1.193.96.115.7.14 |
The time the fault was detected. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
eventTime |
1.3.6.1.4.1.193.96.115.7.17 |
The time the event occured. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DateAndTime |
|
|
ntId |
1.3.6.1.4.1.193.96.115.7.18 |
Customer id or network terminal id or radio terminal id |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..32) |
|
cellbusFailure |
5 |
This is sent when a Cellbus has a defect
that is longer than 2.5+/-0.5 seconds. |
TRAP-TYPE |
|
|
|
fanFailure |
6 |
Is sent when a fan failure has been detected in the subrack (this could be based on detection of over_temperature in the subrack) An alarm ceasing report (alarm severity ='cleared') will be sent when an indication that the fan is back in operation has been detected. |
TRAP-TYPE |
|
|
|
powerFailure |
7 |
Is sent when a power failure has been detected in the subrack. An alarm ceasing report (alarm severity = 'cleared') will be sent when an indication that the power is back on has been detected. |
TRAP-TYPE |
|
|
|
communicationLost |
1 |
Is sent when a the communication to a subrack
has been lost. An alarm ceasing report (alarm
severity = 'cleared') will be sent when the
communication has been re-established.
The alarm type is by default 'communication alarm'. |
TRAP-TYPE |
|
|
|
boardReplaced |
2 |
Is sent when the insertion of a circuit board
that matches the configured data for the slot
(but not the serial number) has been detected. |
TRAP-TYPE |
|
|
|
boardRemovedAlarm |
4 |
Is sent when the removal of a matching circuit board
from a slot has been detected. An alarm ceasing report
(alarm severity = 'cleared') will be sent when a board
is inserted in the slot, or when the configuration data
is cleared for the slot.
The alarm type is by default 'equipment alarm'. |
TRAP-TYPE |
|
|
|
boardMismatch |
6 |
Is sent when the insertion of a circuit board
that does not match the configured data for the
slot has been detected. An alarm ceasing report
(alarm severity = 'cleared') will be sent when
matching configuration data is set for the slot,
when the configuration data is cleared for
the slot, or when the board is removed.
The alarm type is by default 'equipment alarm'. |
TRAP-TYPE |
|
|
|
boardUnrecognized |
7 |
Is sent when the insertion of a circuit board
in a slot has been detected, but the board ID
is not recognizable (or not valid for this system).
An alarm ceasing report (alarm severity = 'cleared')
will be sent when the board is removed.
The alarm type is by default 'equipment alarm'. |
TRAP-TYPE |
|
|
|
powerLoss |
8 |
Is sent when a power loss occurs at a board. |
TRAP-TYPE |
|
|
|
atRollbacked |
46 |
This is sent when the software is downloaded |
TRAP-TYPE |
|
|
|
communicationError |
9 |
Is sent when a communication error condition has been
entered (or ceased) on a circuit board.
The alarm type is by default 'equipment alarm'. |
TRAP-TYPE |
|
|
|
startError |
12 |
Is sent when a start error condition has been
entered (or ceased) on a circuit board.
The alarm type is by default 'equipment alarm'. |
TRAP-TYPE |
|
|
|
laserPower |
13 |
This is sent when a failure of the laser power occurs. |
TRAP-TYPE |
|
|
|
bufferOverflow |
16 |
This is sent when a buffer overflows for a while |
TRAP-TYPE |
|
|
|
bufferUnderflow |
17 |
This is sent when a buffer underflows for a while |
TRAP-TYPE |
|
|
|
downLoadLmFailed |
19 |
This is sent when the downloading of a new Load Module (LM)
to a Device Processor (DP) fails |
TRAP-TYPE |
|
|
|
incorrectSwVersion |
21 |
This is sent when a board has been loaded with
the incorrect version of software. |
TRAP-TYPE |
|
|
|
vpAis |
23 |
This is sent when a VP AIS alarm occurs. |
TRAP-TYPE |
|
|
|
vpRdi |
24 |
This is sent when a VP RDI alarm occurs. |
TRAP-TYPE |
|
|
|
msAis |
27 |
This is sent when Alarm Indication Signal
is received for more than 2.5 seconds on a
Multiplexer Section. |
TRAP-TYPE |
|
|
|
msRdi |
28 |
This is sent when Remote Defect Indication
is received for more than 2.5 seconds on a
Multiplexer Section. |
TRAP-TYPE |
|
|
|
pathRdi |
29 |
This is sent when Remote Defect Indication
is received for more than 2.5 seconds on a
Path. |
TRAP-TYPE |
|
|
|
pathAis |
30 |
This is sent when Alarm Indication Signal
is received for more than 2.5 seconds on a
Path. |
TRAP-TYPE |
|
|
|
macModemSwDownloadFailure |
18 |
the download from the MAC EPROM active or passive towards the passive area of modem has failed |
TRAP-TYPE |
|
|
|
macRadioSwDownloadFailure |
20 |
the download from the MAC EPROM active or passive towards the passive area of radio has failed |
TRAP-TYPE |
|
|
|
macIncorrSwVersModem |
42 |
The active loadmodule in the modem contains an incorrect SW version. |
TRAP-TYPE |
|
|
|
macIncorrSwVersRadio |
43 |
The active loadmodule in the radio contains an incorrect SW version. |
TRAP-TYPE |
|
|
|
macKeepAliveFail |
49 |
MAC-Radio Control Communication Link Failure. The ping toward the radio doesn't come back to the mac three consecutive times |
TRAP-TYPE |
|
|
|
macSignonFailed |
12 |
Sent when the AT which should be signed on is lost. |
TRAP-TYPE |
|
|
|
radioTxOn |
77 |
Transmitter always on. |
TRAP-TYPE |
|
|
|
radioVco |
78 |
Radio VCO has a reduced margin. |
TRAP-TYPE |
|
|
|
radioTxLevel |
79 |
Unable to adjust radio output power level. |
TRAP-TYPE |
|
|
|
radioTxVco |
104 |
The TX VCO has reached a reduced action margin in the Radio Unit. |
TRAP-TYPE |
|
|
|
suMismatch |
65 |
A SU of wrong type has been inserted in a configured SU slot. |
TRAP-TYPE |
|
|
|
aal1SarFailure |
106 |
Sent when a temporary loss of traffic due to AAL1 device failure is detected. |
TRAP-TYPE |
|
|
|
radioTxLos |
70 |
IF input level from modem too low. |
TRAP-TYPE |
|
|
|
radioRfOut |
71 |
RF output level to antenna too low. |
TRAP-TYPE |
|
|
|
radioTxOffFail |
52 |
The radio is set off but is still trasmitting |
TRAP-TYPE |
|
|
|
radioRxIfc |
73 |
Rx intermediate IF PLL unlocked. |
TRAP-TYPE |
|
|
|
radioIrsLoss |
94 |
RF input power level too low on average on all the transmitting terminals |
TRAP-TYPE |
|
|
|
modemEberUp |
100 |
Uplink Eber received in modem is above limit. |
TRAP-TYPE |
|
|
|
modemEberDown |
101 |
Downlink Eber received in modem is above limit. |
TRAP-TYPE |
|
|
|
modemRxlFinUp |
102 |
Uplink IF input level from RAU too low. |
TRAP-TYPE |
|
|
|
modemModInd |
85 |
Unable to adjust modulation index. |
TRAP-TYPE |
|
|
|
swDownloadFailureRadio |
54 |
the download from the NU FPROM active or passive towards the passive area of radio has failed |
TRAP-TYPE |
|
|
|
swDownloadFailureModem |
55 |
the download from the NU FPROM active or passive towards the passive area of modem has failed |
TRAP-TYPE |
|
|
|
radioMismatch |
84 |
UKL received different from UKL configured |
TRAP-TYPE |
|
|
|
radioFrequencyMismatch |
111 |
Configured Frequency is not within the restricted frequency range of the installed Radio Unit |
TRAP-TYPE |
|
|
|
aal1Starvation |
91 |
Sent when a buffer-underflow condition is detected. |
TRAP-TYPE |
|
|
|
systemUp |
0 |
This is sent when the CP has initialised. |
TRAP-TYPE |
|
|
|
systemAudit |
57 |
Generated by the CP to notify that a CP start/restart is ongoing. |
TRAP-TYPE |
|
|
|
rnSwitched |
11 |
A switch between a providing_service RN board with a cold_standby one has been performed. |
TRAP-TYPE |
|
|
|
masterLinkSwitched |
107 |
A switch between the link that is giving the synchronization at the system node. |
TRAP-TYPE |
|
|
|
licenseCapacityEvent |
108 |
This event is sent when 85%, 90% or 95% of license capacity is reached. |
TRAP-TYPE |
|
|
|
licenseExpirationEvent |
109 |
This event is sent once a day starting from 10 days before expiration date. |
TRAP-TYPE |
|
|
|
hostidMismatch |
110 |
This event is sent at System Restart if a hostid mismatch exists. |
TRAP-TYPE |
|
|
|
signOnComplete |
37 |
This is a notification that the sign on of an NT/AT
is completed. |
TRAP-TYPE |
|
|
|
modemRestart |
89 |
This is a notification that the sign on of an NT/AT
is completed. |
TRAP-TYPE |
|
|
|
alarmDisturbance |
38 |
This notification is sent if an alarm state changes
frequently. |
TRAP-TYPE |
|
|
|
selfTestOk |
39 |
Loop on radio is working, i.e. mac, modem and radio have no faults. |
TRAP-TYPE |
|
|
|
los |
1 |
This is sent when a Loss Of Signal has been detected. |
TRAP-TYPE |
|
|
|
lof |
2 |
This is sent when a Loss Of Frame has been detected. |
TRAP-TYPE |
|
|
|
lop |
3 |
This is sent when a Loss Of Pointer has been detected. |
TRAP-TYPE |
|
|
|
ais |
4 |
This is sent when an Alarm Indication Signal
has been detected. |
TRAP-TYPE |
|
|
|
lofMf |
95 |
This is sent when a Loss Of MultiFrame has been detected. |
TRAP-TYPE |
|
|
|
rai |
6 |
This is sent when a Remote Alarm Indication has been detected. |
TRAP-TYPE |
|
|
|
subrackMismatch |
31 |
The subrack is wrongly configured in the configuration files.
Power Management enabled even if no check in the hardware is
performed. |
TRAP-TYPE |
|
|
|
externalAlarm1 |
62 |
Is sent when an external alarm has been detected in the subrack
(this is based on detection of relay alarm on input MISC 1 of
the subrack ). An alarm ceasing report (alarm severity = 'cleared')
will be sent when an indication that the external alarm is ceased
has been detected. |
TRAP-TYPE |
|
|
|
externalAlarm2 |
64 |
Is sent when an external alarm has been detected in the subrack
(this is based on detection of relay alarm on input MISC 2 of
the subrack ). An alarm ceasing report (alarm severity = 'cleared')
will be sent when an indication that the external alarm is ceased
has been detected. |
TRAP-TYPE |
|
|
|
lossOfNetSync |
61 |
This is sent when critical alarms are detected
at DPSW level on a specific board (ET/CE),
which is master for the network. |
TRAP-TYPE |
|
|
|
diskFull |
97 |
The filesystem on a disk in the CP is almost full. |
TRAP-TYPE |
|
|
|
hwFailure |
98 |
Sent when DP has reported faulty HW. |
TRAP-TYPE |
|
|
|
suRemoved |
99 |
Sent when SU has been removed. |
TRAP-TYPE |
|
|
|