ALCATEL-IND1-CHASSIS-MIB

File: ALCATEL-IND1-CHASSIS-MIB.mib (125023 bytes)

Imported modules

SNMPv2-SMI ENTITY-MIB ALCATEL-IND1-BASE
SNMP-FRAMEWORK-MIB SNMPv2-TC SNMPv2-CONF

Imported symbols

OBJECT-TYPE OBJECT-IDENTITY MODULE-IDENTITY
NOTIFICATION-TYPE Unsigned32 Integer32
IpAddress Counter32 PhysicalIndex
entPhysicalIndex hardentIND1Physical hardentIND1Chassis
SnmpAdminString MacAddress TruthValue
DisplayString TEXTUAL-CONVENTION MODULE-COMPLIANCE
OBJECT-GROUP NOTIFICATION-GROUP

Defined Types

AlaChasBpsShelfId  
BPS shelf Id .
TEXTUAL-CONVENTION    
  Integer32 1..3  

ChasTrapsBPSPowerSupply  
Textual convention for type of bps power supply.
TEXTUAL-CONVENTION    
  INTEGER bpsSysPower1(1), bpsSysPower2(2), bpsPoePower1(3), bpsPoePower2(4), bpsPoePower3(5), notApplicable(6)  

ChasTrapsBPSFetState  
Textual convention for BPS FET state
TEXTUAL-CONVENTION    
  INTEGER on(1), off(2), notApplicable(3)  

ChasTrapsBPSEventAlert  
Textual convention for BPS event alert
TEXTUAL-CONVENTION    
  INTEGER bpsPsPlugged(1), bpsPsUnPlugged(2), notApplicable(3)  

ChasControlModuleEntry  
SEQUENCE    
  chasControlActivateTimeout Integer32
  chasControlVersionMngt INTEGER
  chasControlDelayedActivateTimer Unsigned32
  chasControlCertifyStatus INTEGER
  chasControlSynchronizationStatus INTEGER
  chasControlAcrossCmmWorkingSynchroStatus INTEGER
  chasControlAcrossCmmCertifiedSynchroStatus INTEGER
  chasControlNextRunningVersion SnmpAdminString
  chasControlCurrentRunningVersion SnmpAdminString
  chasControlWorkingVersion SnmpAdminString
  chasControlRedundancyTime Integer32
  chasControlEmpIpAddress IpAddress
  chasControlEmpIpMask IpAddress
  chasControlChassisId Integer32

ChasControlRedundantEntry  
SEQUENCE    
  chasControlNumberOfTakeover Counter32
  chasControlDelayedRebootTimer Unsigned32
  chasControlDelayedResetAll Integer32

ChasChassisEntry  
SEQUENCE    
  chasFreeSlots Unsigned32
  chasPowerLeft Integer32
  chasNumberOfResets Counter32
  chasTempRange INTEGER
  chasTempThreshold Integer32
  chasDangerTempThreshold Integer32
  chasPrimaryPhysicalIndex Integer32
  chasCPMAHardwareBoardTemp Integer32
  chasCFMAHardwareBoardTemp Integer32
  chasCPMBHardwareBoardTemp Integer32
  chasCFMBHardwareBoardTemp Integer32
  chasCFMCHardwareBoardTemp Integer32
  chasCFMDHardwareBoardTemp Integer32
  chasFTAHardwareBoardTemp Integer32
  chasFTBHardwareBoardTemp Integer32
  chasNI1HardwareBoardTemp Integer32
  chasNI2HardwareBoardTemp Integer32
  chasNI3HardwareBoardTemp Integer32
  chasNI4HardwareBoardTemp Integer32
  chasNI5HardwareBoardTemp Integer32
  chasNI6HardwareBoardTemp Integer32
  chasNI7HardwareBoardTemp Integer32
  chasNI8HardwareBoardTemp Integer32
  chasPowerSupplyRedundancy INTEGER

ChasEntPhysLed  
Textual convention for physical LEDs. Note: Due to European regulation, the LEDs will never be illuminated in red, but will be either green or amber.
TEXTUAL-CONVENTION    
  INTEGER notApplicable(0), off(1), greenOn(2), greenBlink(3), amberOn(4), amberBlink(5)  

ChasEntPhysicalEntry  
SEQUENCE    
  chasEntPhysAdminStatus INTEGER
  chasEntPhysOperStatus INTEGER
  chasEntPhysPower Integer32
  chasEntPhysModuleType SnmpAdminString
  chasEntPhysPartNumber SnmpAdminString
  chasEntPhysLedStatusOk1 ChasEntPhysLed
  chasEntPhysLedStatusOk2 ChasEntPhysLed
  chasEntPhysLedStatusPrimaryCMM ChasEntPhysLed
  chasEntPhysLedStatusSecondaryCMM ChasEntPhysLed
  chasEntPhysLedStatusTemperature ChasEntPhysLed
  chasEntPhysLedStatusFan ChasEntPhysLed
  chasEntPhysLedStatusBackupPS ChasEntPhysLed
  chasEntPhysLedStatusInternalPS ChasEntPhysLed
  chasEntPhysLedStatusControl ChasEntPhysLed
  chasEntPhysLedStatusFabric ChasEntPhysLed
  chasEntPhysLedStatusPS ChasEntPhysLed
  chasEntPhysAsic1Rev SnmpAdminString
  chasEntPhysAsic2Rev SnmpAdminString
  chasEntPhysAsic3Rev SnmpAdminString
  chasEntPhysAsic4Rev SnmpAdminString
  chasEntPhysAsic5Rev SnmpAdminString
  chasEntPhysAsic6Rev SnmpAdminString
  chasEntPhysCpldRev SnmpAdminString
  chasEntPhysDaughterFpga1Rev SnmpAdminString
  chasEntPhysDaughterFpga2Rev SnmpAdminString
  chasEntPhysNiNum Integer32
  chasEntPhysGbicNum Integer32
  chasEntPhysWaveLen Integer32
  chasEntPhysUbootRev SnmpAdminString
  chasEntPhysUbootMinibootRev SnmpAdminString
  chasEntPhysMacAddress MacAddress
  chasEntPhysCpuModel SnmpAdminString
  chasEntPhysAirflow INTEGER
  chasEntPhysPowerUsed Integer32

ChasEntTemperatureEntry  
SEQUENCE    
  chasEntTempCurrent Integer32
  chasEntTempThreshold Integer32
  chasEntTempDangerThreshold Integer32
  chasEntTempStatus INTEGER

ChasSupervisionRfsLsEntry  
SEQUENCE    
  chasSupervisionRfsLsFileIndex Integer32
  chasSupervisionRfsLsSlot Unsigned32
  chasSupervisionRfsLsDirName SnmpAdminString
  chasSupervisionRfsLsFileName SnmpAdminString
  chasSupervisionRfsLsFileType INTEGER
  chasSupervisionRfsLsFileSize Unsigned32
  chasSupervisionRfsLsFileAttr INTEGER
  chasSupervisionRfsLsFileDateTime SnmpAdminString

ChasSupervisionRfsDfEntry  
SEQUENCE    
  chasSupervisionRfsDfSlot Integer32
  chasSupervisionRfsDfFlashFree Unsigned32
  chasSupervisionRfsDfFlashSize Unsigned32
  chasSupervisionRfsDfUsbFree Unsigned32
  chasSupervisionRfsDfUsbSize Unsigned32

ChasSupervisionFlashMemEntry  
SEQUENCE    
  chasSupervisionSlot Integer32
  chasSupervisionFlashSize Unsigned32
  chasSupervisionFlashFree Unsigned32
  chasSupervisionFlashUsed Integer32

ChasSupervisionCmmCertifiedEntry  
SEQUENCE    
  chasSupervisionCmmNum Integer32
  chasSupervisionCmmCertifiedStatus INTEGER

AlaChasEntPhysFanEntry  
SEQUENCE    
  alaChasEntPhysFanLocalIndex Integer32
  alaChasEntPhysFanStatus INTEGER
  alaChasEntPhysFanAirflow INTEGER

ChasControlReloadEntry  
SEQUENCE    
  chasControlReloadIndex Integer32
  chasControlReloadStatus INTEGER

AlaChasBpsFwEntry  
SEQUENCE    
  alaChasBpsShelfId AlaChasBpsShelfId
  alaChasBpsUpdateFirmware INTEGER
  alaChasBpsCpldRev SnmpAdminString
  alaChasBpsMmcuRev SnmpAdminString
  alaChasBpsCmcuRev SnmpAdminString

AlaChasBpsConnectorPriorityEntry  
SEQUENCE    
  alaChasBpsChassisId Integer32
  alaChasBpsConnectorShelfId AlaChasBpsShelfId
  alaChasBpsConnectorPriority Integer32
  alaChasBpsConnectorNum SnmpAdminString
  alaChasBpsSerialNum SnmpAdminString

AlaChasBpsModeEntry  
SEQUENCE    
  alaChasBpsMode INTEGER

AlaChasBpsPowerSupplyEntry  
SEQUENCE    
  alaChasBpsPowerSupplyShelfId AlaChasBpsShelfId
  alaChasBpsPowerSupplyIndex Integer32
  alaChasBpsPowerSupplyName SnmpAdminString
  alaChasBpsPowerSupplyDescr SnmpAdminString
  alaChasBpsPowerSupplyModuleType SnmpAdminString
  alaChasBpsPowerSupplyPartNumber SnmpAdminString
  alaChasBpsPowerSupplyHardwareRev SnmpAdminString
  alaChasBpsPowerSupplySerialNum SnmpAdminString
  alaChasBpsPowerSupplyMfgDate SnmpAdminString
  alaChasBpsPowerSupplyOperStatus INTEGER
  alaChasBpsPowerSupplyPowerProv Integer32

AlaChasBpsTotalPowerAllocEntry  
SEQUENCE    
  alaChasBpsSysTotalAvailablePower Integer32
  alaChasBpsSysTotalAllocation Integer32
  alaChasBpsPoeTotalAvailablePower Integer32
  alaChasBpsPoeTotalAllocation Integer32

ChassisTrapsStrLevel  
enumerated value which provide the urgency level of the STR.
TEXTUAL-CONVENTION    
  INTEGER strNotFatal(1), strApplicationFatal(2), strFatal(3)  

ChassisTrapsStrAppID  
Application Identification number
TEXTUAL-CONVENTION    
  Integer32 0..255  

ChassisTrapsStrSnapID  
Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs.
TEXTUAL-CONVENTION    
  Integer32 0..255  

ChassisTrapsStrfileLineNb  
Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__.
TEXTUAL-CONVENTION    
  Integer32 1..65535  

ChassisTrapsStrErrorNb  
Fault identifier. The error number identifies the kind the detected fault and allows a mapping of the data contained in chassisTrapsdataInfo.
TEXTUAL-CONVENTION    
  Integer32 0..65535  

ChassisTrapsStrdataInfo  
Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes.
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..63)  

ChassisTrapsObjectType  
An enumerated value which provides the object type involved in the alert trap.
TEXTUAL-CONVENTION    
  INTEGER chassis(1), ni(2), powerSuply(3), fan(4), cmm(5), fabric(6), gbic(7)  

ChassisTrapsObjectNumber  
A number defining the order of the object in the set. EX: The number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. An instance of the appearance of the trap could be: failure on a module. Power supply 3.
TEXTUAL-CONVENTION    
  Integer32 0..255  

ChassisTrapsAlertNumber  
this number identify the alert among all the possible chassis alert causes.
TEXTUAL-CONVENTION    
  INTEGER runningWorking(1), runningCertified(2), certifyStarted(3), certifyFlashSyncStarted(4), certifyCompleted(5), certifyFailed(6), synchroStarted(7), synchroCompleted(8), synchroFailed(9), restoreStarted(10), restoreCompleted(11), restoreFailed(12), takeoverStarted(13), takeoverDeferred(14), takeoverCompleted(15), macAllocFailed(16), macRangeFailed(17), fanFailed(18), fanOk(19), fansOk(20), tempOverThreshold(21), tempUnderThreshold(22), tempOverDangerThreshold(23), powerMissing(24), psNotOperational(25), psOperational(26), psAllOperational(27), redundancyNotSupported(28), redundancyDisabledCertifyNeeded(29), cmmStartingAsPrimary(30), cmmStartingAsSecondary(31), cmmStartupCompleted(32), cmmAPlugged(33), cmmBPlugged(34), cmmAUnPlugged(35), cmmBUnPlugged(36), lowNvramBattery(37), notEnoughFabricsOperational(38), simplexNoSynchro(39), secAutoActivate(40), secAutoCertifyStarted(41), secAutoCertifyCompleted(42), secInactiveReset(43), activateScheduled(44), activateStarted(45), getAfileCompleted(46), getAfileFailed(47), sysUpdateStart(48), sysUpdateInProgress(49), sysUpdateError(50), sysUpdateEnd(51), reloadInProgress(52), c20UpgradeOk(53), c20UpgradeFailed(54), c20RestoreOk(55), c20RestoreFailed(56), c20NiFailed(57), airflowReverse(58), tempSWHigh(59), tempHWHigh(60), tempDanger(61), imageFileChecksumChanged(62)  

Defined Values

alcatelIND1ChassisMIB 1.3.6.1.4.1.6486.801.1.1.1.3.1
This module describes an authoritative enterprise-specific Simple etwork Management Protocol (SNMP) Management Information Base (MIB): For the Birds Of Prey Product Line, this is the Chassis Supervision Chassis MIB for managing physical chassis objects not covered in the IETF Entity MIB (rfc 2737). The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used. Copyright (C) 1995-2007 Alcatel-Lucent ALL RIGHTS RESERVED WORLDWIDE
MODULE-IDENTITY    

alcatelIND1ChassisMIBNotifications 1.3.6.1.4.1.6486.801.1.1.1.3.1.0
Branch For Chassis MIB Subsystem Notifications.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisMIBObjects 1.3.6.1.4.1.6486.801.1.1.1.3.1.1
Branch For Chassis Supervision Chassis MIB Subsystem Managed Objects.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisMIBConformance 1.3.6.1.4.1.6486.801.1.1.1.3.1.2
Branch For Chassis Supervision Chassis MIB Subsystem Conformance Information.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisMIBGroups 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1
Branch For Chassis Supervision Chassis MIB Subsystem Units Of Conformance.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisMIBCompliances 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.2
Branch For Chassis Supervision Chassis MIB Subsystem Compliance Statements.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisPhysMIBObjects 1.3.6.1.4.1.6486.801.1.1.1.1.1
Branch For Chassis Supervision Chassis Physical MIB Subsystem Managed Objects.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisPhysMIBConformance 1.3.6.1.4.1.6486.801.1.1.1.1.2
Branch For Chassis Supervision Chassis Physical MIB Subsystem Conformance Information.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisPhysMIBGroups 1.3.6.1.4.1.6486.801.1.1.1.1.2.1
Branch For Chassis Supervision Chassis Physical MIB Subsystem Units Of Conformance.
Status: current Access: read-only
OBJECT-IDENTITY    

alcatelIND1ChassisPhysMIBCompliances 1.3.6.1.4.1.6486.801.1.1.1.1.2.2
Branch For Chassis Supervision Chassis Physical MIB Subsystem Compliance Statements.
Status: current Access: read-only
OBJECT-IDENTITY    

chasControlModuleTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1
This table contains one row for the primary control module.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasControlModuleEntry

chasControlModuleEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1
Information about the primary control module. This table is an extension of the entity physical table but this class is instanciated only for a the primary control module that has a particular Index. When operatiing in virtual chassis mode only the master primary control module is instanciated
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasControlModuleEntry  

chasControlActivateTimeout 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.1
This value is in seconds. It represents how much time before the switch automatically falls back to the certified version. This value is set via the Activate(reload working) cli command. An Activate reboot must be initiated via the primary CMM and that the timeout value can be accessed via user interface to the primary CMM only. After the Activate reboot has been initiated, a timeout will occur (i.e., an Activate Timeout) at the timeout value specified by the user. If a reboot cancel has not been received prior to the timeout expiration, the primary CMM will automatically reboot (i.e., re-reboot) using the certified configuration. This ensures that an automatic backup reboot is available using the certified configuration in the event that the user is unable to interface with primary CMM as a result of the attempted Activate reboot. If the Activate reboot is successful, the user cancels the backup reboot via the normal reboot cancellation process (i.e., a zero value is written for the object chasControlDelayedRebootTimer).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

chasControlVersionMngt 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.2
For the primary this means: notSignificant - No command applied. certifySynchro - Copy the file from the working to the certified directory and from the primary to the secondary (reboot of the secondary). certifyNoSynchro - Copy the file from the working to the certified directory. flashSynchro - Copy the file from the primary to the secondary (reboot of the secondary). restore - Copy the file from the certified directory to the working directory. activate - Reload from the working directory. Activate can be scheduled. issu - In Service Software Upgrade (ISSU). shutdown - Shutdown chassis specified by chasControlChassisId. Halts and powers off NIs, halts primary and secondary CMMs. vcConvert - Copy the image files from the running directory to the working directory.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSignificant(1), certifySynchro(2), certifyNoSynchro(3), flashSynchro(4), restore(5), activate(6), issu(7), shutdown(8), vcConvert(9)  

chasControlDelayedActivateTimer 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.3
Timer value in seconds used to initiate a delayed activate of the primary CMM. Writing this object to a non-zero value results in CMM reboot of the working directory following expiration of the specified activate timer delay. Writing this object to zero results in an immediately activate process. It is now adjusted to wait a maximum of 366 days.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..31622400  

chasControlCertifyStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.4
Returned value indicates if the control module has been certified (that is the working directory matches the certified directory)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), needCertify(2), certified(3)  

chasControlSynchronizationStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.5
Returned value indicates if the control module has been synchronized (that is the working directory matches the working directory on the other control module(s) if present). Returned value is monoControlModule when no other control module is present.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), monoControlModule(2), notSynchronized(3), synchronized(4)  

chasControlAcrossCmmWorkingSynchroStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.6
Returned value indicates if the /working has been synchronized across the CMMs (that is the working directory matches the working directory on all CMMs if present)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), monoCMM(2), no(3), yes(4)  

chasControlAcrossCmmCertifiedSynchroStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.7
Returned value indicates if the /certified has been synchronized across the CMMs if present)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), monoCMM(2), no(3), yes(4)  

chasControlNextRunningVersion 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.8
The pathname for the image directory that will be used on the next reload. Value may be /flash/certified or /flash/.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

chasControlCurrentRunningVersion 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.9
The pathname of the image directory to the version that is currently executing. Value may be /flash/certified or /flash/.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

chasControlWorkingVersion 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.10
The path to the currently specified working image directory. Value may be /flash/certified or /flash/.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString  

chasControlRedundancyTime 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.11
Time in minutes that the running image must stay up without error before a subsequent error reset will restart the board from the running image. If a CMM in dual-CMM switch fails after a reload and before chasControlRedundancyTime expires, both CMMs will be rebooted from the certified version.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..900  

chasControlEmpIpAddress 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.12
This object is deprecated. Instead use alaInterfaceTable(ALCATEL-IND1-IP-MIB) when configuring EMP interfaces. The IP Address for the primary control module EMP interface. This address is used for managing the chassis and will continue as the EMP interface address after a takeover.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

chasControlEmpIpMask 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.13
This object is deprecated. Instead use alaInterfaceTable(ALCATEL-IND1-IP-MIB) when configuring EMP interfaces. The IP Address Mask for the primary control module EMP interface. This address mask is used for managing the chassis and will continue as the EMP interface mask after a takeover.
Status: deprecated Access: read-write
OBJECT-TYPE    
  IpAddress  

chasControlChassisId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.1.1.14
The virtual chassis id for the action specified by chasControlVersionMngt when operating in virtual chassis mode. A value of 0 indicates the local chassis.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16  

chasControlRedundantTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2
This table contains one row per control module. There is always at least one control module in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasControlRedundantEntry

chasControlRedundantEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1
Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index. When running in virtual chassis mode, entries are instantiated for the Master and all the slave CMMs
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasControlRedundantEntry  

chasControlNumberOfTakeover 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.1
This object is a count of the number of times the control module has changed from primary to secondary mode as a result of a Takeover. Note that this object can be accessed via user interface to either the primary or secondary CMM. The value returned is the number of times that the interfacing control module (either primary or secondary CMM) has changed from primary to secondary mode. This value does not reflect the total number of CMM Takeovers for the switch. To get the total number of Takeovers for the switch, it is necessary to read this value via user interface to each control module independently.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

chasControlDelayedRebootTimer 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.2
Timer value (in seconds) used to initiate a delayed reboot of the primary or secondary CMM using the certified configuration. Writing this object to a non-zero value results in a CMM reboot following expiration of the specified reset timer delay. Writing this object to zero results in cancellation of a pending CMM delayed reboot. It is now adjusted to wait a maximum of 366 days.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..31622400  

chasControlDelayedResetAll 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.2.1.3
This object is used to schedule a delayed reset all action for a chassis when running in virtual chassis mode. If set to -1 - cancel the timer, 0 - reset all immediately, any other value will start counting down the time until reset.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

chasChassisTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3
This table contains one row per chassis. There is always at least one chassis or many when running in virtual chassis mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasChassisEntry

chasChassisEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1
Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasChassisEntry  

chasFreeSlots 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.1
The number of free NI front panel slots.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..18  

chasPowerLeft 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.2
The power still available on the chassis in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -100000..100000  

chasNumberOfResets 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.3
This object is a count of the number of times this station has been reset since a cold-start.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

chasTempRange 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.4
Temp Range is the value of the temperature sensor for the chassis. The Temp Range value reflects the temperature of the chassis relative to the Temp Threshold value (i.e., over vs. under the threshold).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notPresent(2), underThreshold(3), overFirstThreshold(4), overDangerThreshold(5)  

chasTempThreshold 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.5
This object is the threshold temperature in degrees Celsius for the chassis. Temp Threshold is the chassis temperature point at which, when reached due to an ascending or descending temperature transition, a temperature notification is provided to the user. When this threshold is exceeded, we start sending traps and other operator notification.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..150  

chasDangerTempThreshold 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.6
This Threshold is a second one which is hardcoded. When the Chassis Exceeds this value it starts shutting down NIs. This value will be set by the factory and not changeable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 30..150  

chasPrimaryPhysicalIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.7
This value holds the Entity Table Physical Index for the Control Module that is currently primary. This is to allow snmp managers to determine which Control Module is currently primary so it knows what entry in the chasControlModuleTable to access for setting the chasControlVersionMngt values for controling the switch. When running in virtual chassis mode, it will contain the Physical Index of the master primary Control Module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..255  

chasCPMAHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.8
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CPMA control module board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasCFMAHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.9
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMA fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasCPMBHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.10
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CPMB control module board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasCFMBHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.11
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMB fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasCFMCHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.12
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMC fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasCFMDHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.13
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the CFMD fabric board. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasFTAHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.14
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for Fantray 1. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasFTBHardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.15
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for Fantry 2. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI1HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.16
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 1. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI2HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.17
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 2. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI3HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.18
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 3. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI4HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.19
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 4. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI5HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.20
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 5. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI6HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.21
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 6. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI7HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.22
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 7. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasNI8HardwareBoardTemp 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.23
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for the NI board in slot 8. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasPowerSupplyRedundancy 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.3.1.24
This object indicates the state of power supply redundancy mode. When on(1), N+1 mode redundancy is enabled(default mode). In this mode the system controls the power supplies to maintain efficient use of the power supplies, with 1 extra power supply in case of a power supply failure. Unneeded power supplies are powered off. It can be set to off(2) to disable redundancy mode. In this mode all power supplies are powered on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

chasEntPhysicalTable 1.3.6.1.4.1.6486.801.1.1.1.1.1.1
This table contains one row per physical entity. It is an extension for the entity physical table (rfc 2737) that is instantiated for every physical entity object. The fields are not always significant for every object.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasEntPhysicalEntry

chasEntPhysicalEntry 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1
Information about a particular physical entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasEntPhysicalEntry  

chasEntPhysAdminStatus 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.1
All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value: powerOn <=> powered up Control Module possible value: powerOn <=> CM up and running reset <=> CM reset takeover <=> Secondary CM takes over resetAll <=> resets the whole switch vcTakeover <=> Reloads master chassis from the current working directory, which initiates a VC takeover. vcResetAll <=> resets entire VC. NI status possible value: powerOn <=> NI is either powered (up or down) or waiting to be powered whenever more power is available. This admin status has not full meaning without chasEntPhysOperStatus powerOff <=> NI down and unpowered and NI will not be powered until user requests it, a failover happens or a reboot happens reset <=> NI reset FABRIC status possible value: powerOn <=> FABRIC is powered powerOff <=> FABRIC is unpowered standby <=> FABRIC is powered and requested to be redundant (inactive) Daughter board status possible value: powerOn <=> DB up and running reset <=> DB reset (TO BE CONFIRMED) Power supply status possible value: powerOn <=> PS up
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), powerOff(2), powerOn(3), reset(4), takeover(5), resetAll(6), standby(7), resetWithFabric(8), takeoverWithFabrc(9), vcTakeover(10), resetVcAll(11)  

chasEntPhysOperStatus 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.2
All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered secondary <=> CM in secondary mode and running NI status possible value : notPresent <=> NI not present up <=> NI up and running down <=> NI down and powered unpowered <=> NI unpowered because there is not enough power in the system (chasEntPhysAdminStatus = powerOn) or because the NI has to be OFF (chasEntPhysAdminStatus = powerOff). This operational status has not full meaning without chasEntPhysAdminStatus Fabric status possible value : master <=> up and acting as master up <=> up and acting as slave secondary <=> secondary mode for redundancy Daughter board status possible value : notPresent <=> DB not present up <=> DB up and running down <=> DB down and powered Power supply status possible value : up <=> PS up down <=> PS administratively down unpowered <=> PS not plugged in pwrsave <=> chassis in powersave mode, supply turned off Fan Tray status possible value : up <=> powered up down <=> powered down fault <=> fault detected
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3), unknown(4), secondary(5), notPresent(6), unpowered(7), master(8), idle(9), pwrsave(10)  

chasEntPhysPower 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.3
This value is only applicable to the NI, PS and Control Modules. It corresponds to a a static value for the power consumption of an NI module or Control Module. This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

chasEntPhysModuleType 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.4
This object is the unique Module Type or ID from the entities eeprom. This value is guarrantteed to be unique to each type of Module. This value is only intended for Alcatel internal use.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString  

chasEntPhysPartNumber 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.5
This object contains the Alcatel Part Number for the entity. This value is used to identify what is needed when placing orders with Alcatel.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

chasEntPhysLedStatusOk1 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.6
Chassis Management Module (CMM) front panel LED OK1 status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusOk2 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.7
Chassis Management Module (CMM) front panel LED OK2 status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusPrimaryCMM 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.8
Chassis Management Module (CMM) front panel LED Primary chassis indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusSecondaryCMM 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.9
Chassis Management Module (CMM) front panel LED Secondary chassis indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusTemperature 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.10
Chassis Management Module (CMM) front panel LED temperature status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusFan 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.11
For Hawk stacks used as a fan group status LED. For eagle CMM's user instead: Fan 1 (top left), Fan 2 (top right), Fan 3 (rear)
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusBackupPS 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.12
Chassis backup power supply status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusInternalPS 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.13
Chassis internal power supply status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusControl 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.14
Chassis control status
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusFabric 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.15
Chassis Management Module (CMM) Fabric status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysLedStatusPS 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.16
Chassis Power Supply Unit status indication
Status: current Access: read-only
OBJECT-TYPE    
  ChasEntPhysLed  

chasEntPhysAsic1Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.17
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysAsic2Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.18
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysAsic3Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.19
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysAsic4Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.20
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysAsic5Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.21
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysAsic6Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.22
This object contains the ASIC revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysCpldRev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.23
This object contains the CPLD revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysDaughterFpga1Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.24
This object contains the daughter fpga revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysDaughterFpga2Rev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.25
This object contains the daughter fpga revision Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysNiNum 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.26
This value is only applicable to the NI. It indicates an NI associated with this physicalEntry
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

chasEntPhysGbicNum 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.27
This value is only applicable to the NI. It indicates a gbic associated with this ni
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

chasEntPhysWaveLen 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.28
This object contains the wave length of a SFP device
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

chasEntPhysUbootRev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.29
This object contains the uboot version Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysUbootMinibootRev 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.30
This object contains the uboot miniboot version Number of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

chasEntPhysMacAddress 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.31
This object contains the MAC address of the ni entity
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

chasEntPhysCpuModel 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.32
This object contains the model description of the cmm/ni cpu
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..32)  

chasEntPhysAirflow 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.33
Chassis PS fan airflow direction
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER frontToRear(0), rearToFront(1), notApplicable(2)  

chasEntPhysPowerUsed 1.3.6.1.4.1.6486.801.1.1.1.1.1.1.1.34
This value is only applicable to the PS. It is the current reading for the power usage of the PS. This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

chasEntTemperatureTable 1.3.6.1.4.1.6486.801.1.1.1.1.1.2
This table contains one row per temperature sensor located on an entity represented by the associated row in the entPhysicalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasEntTemperatureEntry

chasEntTemperatureEntry 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1
Information about a particular physical temperature sensor.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasEntTemperatureEntry  

chasEntTempCurrent 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.1
This object indicates the current output of the temperature sensor in degrees Celsius.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..200  

chasEntTempThreshold 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.2
This object is the threshold temperature in degrees Celsius for the sensor. When the value of chasEntTempCurrent exceeds this value, a temperature notification is provided to the user.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..150  

chasEntTempDangerThreshold 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.3
This object is the danger threshold temperature in degrees Celsius for the sensor. When the value of chasEntTempCurrent exceeds this value, the associated physical entity is powered down.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 30..150  

chasEntTempStatus 1.3.6.1.4.1.6486.801.1.1.1.1.1.2.1.4
This object is the status value of the temperature sensor. It reflects the temperature relative to the chasEntTempThreshold and chasEntTempDangerThreshold values.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), notPresent(2), underThreshold(3), overFirstThreshold(4), overDangerThreshold(5)  

chasSupervisionRfsLsTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4
This table contains a list of file on the remote chassis per directory.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasSupervisionRfsLsEntry

chasSupervisionRfsLsEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1
Information about a remote file. A row in this table contains a file per directory per chassis
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasSupervisionRfsLsEntry  

chasSupervisionRfsLsFileIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.1
This value holds file Index for the RFS LS table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..100  

chasSupervisionRfsLsSlot 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.2
CMM Slot where remote file is located.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsLsDirName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.3
The remote directory name where remote file is located in
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasSupervisionRfsLsFileName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.4
The file name of remote file
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..33)  

chasSupervisionRfsLsFileType 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.5
The Type of a remote file
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER file(1), directory(2), undefined(3), tarArchive(4)  

chasSupervisionRfsLsFileSize 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.6
size of this remote file
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsLsFileAttr 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.7
attributes of this remote file
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER undefined(1), readOnly(2), readWrite(3), writeOnly(4)  

chasSupervisionRfsLsFileDateTime 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.4.1.8
the modification date and time of a remote file
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

chasSupervisionRfsDfTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8
This table contains information about file system size and use.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasSupervisionRfsDfEntry

chasSupervisionRfsDfEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1
This entry contains information about file system size and use.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasSupervisionRfsDfEntry  

chasSupervisionRfsDfSlot 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.1
CMM Slot where flash space is evaluated.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

chasSupervisionRfsDfFlashFree 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.2
Number bytes free on the file system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsDfFlashSize 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.3
Number of total bytes on the file system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsDfUsbFree 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.4
The amount of free space on the USB file system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsDfUsbSize 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.8.1.5
The total amount of space on the USB file system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionFlashMemTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9
This table contains the systems flash memory information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasSupervisionFlashMemEntry

chasSupervisionFlashMemEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1
This contains one entry for the flash memory table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasSupervisionFlashMemEntry  

chasSupervisionSlot 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.1
CMM Slot where flash space is evaluated.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

chasSupervisionFlashSize 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.2
Flash memory size.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionFlashFree 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.3
Number bytes free on file system.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

chasSupervisionFlashUsed 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.9.1.4
A rounded up percentage of Flash Memory used.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..100  

chasSupervisionCmmCertifiedTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10
This table contains certification status
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasSupervisionCmmCertifiedEntry

chasSupervisionCmmCertifiedEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1
Information about control module certification status. This class is instanciated only when running in virtual chassis mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasSupervisionCmmCertifiedEntry  

chasSupervisionCmmNum 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1.1
CMM Slot where /certified directory is evaluated.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..16  

chasSupervisionCmmCertifiedStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.10.1.2
The status of the CMM certified directory - certified or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(0), yes(1), no(2)  

alaChasEntPhysFanTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11
This table contains one row per physical fan entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasEntPhysFanEntry

alaChasEntPhysFanEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1
Information about a particular fan in a chassis physical entity.
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasEntPhysFanEntry  

alaChasEntPhysFanLocalIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.1
Index to a chassis fan entity
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..65535  

alaChasEntPhysFanStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.2
Chassis fan operational status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noStatus(0), notRunning(1), running(2)  

alaChasEntPhysFanAirflow 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.11.1.3
Chassis fan airflow direction
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER frontToRear(0), rearToFront(1), notApplicable(2)  

alcatelIND1ChassisSupervisionRfsCommands 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5
Branch For Chassis Supervision RFS commands. For rrm command the Slot, Command and SrcFileName are mandatory. For rcp command the Slot, Command, SrcFileName and DestFileName are mandatory. For rdf command the Slot and Command are mandatory
Status: current Access: read-only
OBJECT-IDENTITY    

chasSupervisionRfsCommandsSlot 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.1
CMM Slot where RFS command should be executed.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

chasSupervisionRfsCommandsCommand 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.2
This object identifies which of the above Actions is to be performed. The commands are as follows: - rrm Remote file remove - rcp Remote file copy (DEPRECATED please use rget or rput instead) - rls Remote directory listing - rdf Remote flash disk space free - rget Remote file get - rput Remote file put
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSignificant(0), rrm(1), rcp(2), rls(3), rdf(4), rget(5), rput(6), reserved(7)  

chasSupervisionRfsCommandsSrcFileName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.3
The remote file for where the RFS action is executed. This includes also the path so directory name and file name. This object is used when command set to rrm or rget or rput.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasSupervisionRfsCommandsDestFileName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.4
The destination file for where the RFS action is executed. This includes also the path so directory name and file name. This object is used when command set to rget or rput.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasSupervisionRfsCommandsRlsDirName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.5
The remote directory name where remote file is located in. This is used when command set to rls.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasSupervisionRfsCommandsRlsFileName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.6
The remote file name where remote file is located in. This is used when command set to rls.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasSupervisionRfsCommandsProcessingState 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.7
command executing state for the previous set operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inProgress(1), ready(2)  

chasSupervisionRfsCommandsStatusCode 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.5.8
command completetion status error code.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER success(1), slotIsPrimary(2), slotNotExist(3), directoryNotExist(4), fileNotExist(5), maximumFilesExceed(6), noDiskSpace(7), systemBusy(8), systemError(9), directoryNotAllowToRemove(10), permissionDenied(11)  

chasControlReloadStatusTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6
Table containing reload status of each network interface slot or stack module
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChasControlReloadEntry

chasControlReloadEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1
Entry of a network interface reload status
Status: current Access: not-accessible
OBJECT-TYPE    
  ChasControlReloadEntry  

chasControlReloadIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1.1
The index (entPhsycialIndex) value of the network interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..64  

chasControlReloadStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.6.1.2
Returned value indicates if the network interface module is enabled or disabled for reload.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER reloadEnabled(1), reloadDisabled(2), noInterface(3), unknown(4)  

chasGlobalControl 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7
OBJECT IDENTIFIER    

chasGlobalControlDelayedResetAll 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.1
This object is used to schedule a delayed reset all action for a standalone chassis or for the entire virtual chassis when running is virtual chassis mode. To schedule a delayed reset on a specific chassis when running is virtual chassis mode, use the chasControlDelayedResetAll object for the desired chassis. If set to -1 - cancel the timer, 0 - reset all immediately, any other value will start counting down the time until reset.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -1..65535  

chasGlobalControlLongCommand 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.2
This object is used to indicate whether a long-term action is in progress, and if so, what the action is.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), certifySynchro(2), certifyNoSynchro(3), flashSynchro(4), restore(5), reload(6), rfs(7), issu(8), shutdown(9), vcConvert(10), macRelease(11)  

chasGlobalControlLongCommandStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.3
This object indicates the final disposition of the most recent long-term action. When running in virtual chassis mode, the value confirmationRequired(5), indicates that the command identified in chasGlobalControlLongCommand may disrupt the virtual chassis. The command is suspended and requires that chasClobalControlConfirmOperation be set to true, after reviewing the details and accepting the consequences identified by chasGlobalControlConfirmMessage.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), inProgress(2), completeSuccess(3), completeFailure(4), confirmationRequired(5)  

chasGlobalControlUpdateFirmware 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.4
This object initiates a firmware update. The chasGlobalControlUpdateSlot and chasGlobalControlUpdateFilename objects must be set prior to setting this object to start the update. The progress of the update can be monitored by reading chasGlobalControlUpdateStatus.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), ubootCmm(2), ubootNi(3), ubootNiAll(4), ubootCmmAll(5), fpgaCmm(6), fpgaNi(7), fpgaNiDaughterBoard1(8), fpgaNiDaughterBoard2(9), fpgaCmmAll(10)  

chasGlobalControlUpdateSlot 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.5
This object identifies the slot to be updated. The Slot value is the entPhysicalIndex of the NI or CMM entry in the entPhyscialTable. A value of 0 may be specified to update all NIs or CMMs. The value of 0 is supported only for uboot updates.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

chasGlobalControlUpdateFilename 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.6
This object identifies the filename containing the uboot firmware image.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..255)  

chasGlobalControlUpdateStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.7
This object reports the status of the firmware update. The status for the the update identified by chasGlobalControlUpdateFirmware and chasGlobalControlUpdateSlot is returned. When ubootNiAll(4) ubootCmmAll(5) or fpgaCmmAll(10) update is executed, the status of individual NIs or CMMs may be monitored by changing the value of chasGlobalControlUpdateSlot to the desired NI or CMM slot value prior to reading the status. noUpdate(1) - No firmware update has been initiated. updateInProgress(2) - Update is in progress. updateSuccess(3) - The last firmware update was successful. updateFailed(4) - The last firmware update failed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noUpdate(1), updateInProgress(2), updateSuccess(3), updateFailed(4)  

chasGlobalControlConfirmOperation 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.8
When operating in virtual chassis mode, this object can be set to true(1) to confirm that the operation identified by chasGlobalControlLongCommand can proceed. Set to false(2) to cancel the operation. This should only be used when chasGlobalControlLongCommandStatus is set to confirmationRequired(5), and the value of chasGlobalControlConfirmMessage has been reviewed.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

chasGlobalControlConfirmMessage 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.7.9
When operating in virtual chassis mode, this object may be read when chasGlobalControlLongCommandStatus is set to confirmationRequired(5). This will happen when an operation such a reload may disrupt the virtual chassis. This object contains information about the consequences of executing the command identified by chasGlobalControlLongCommand. The command has been suspended. To accept the consequences and proceed with the operation, set chasGlobalControlConfirmOperation to true.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alaChasBpsObjects 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14
OBJECT IDENTIFIER    

alaChasBpsFwTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1
This table contains one row per shelf bps firrmware
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasBpsFwEntry

alaChasBpsFwEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1
Information about a bps firrmare
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsFwEntry  

alaChasBpsShelfId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.1
Bps shelf ID
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsShelfId  

alaChasBpsUpdateFirmware 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.2
This object is used to start BPS firmware update.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

alaChasBpsCpldRev 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.3
This object contains the CPLD revision Number of the BPS
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

alaChasBpsMmcuRev 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.4
This object contains the MMCU revision Number of the BPS
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

alaChasBpsCmcuRev 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.1.1.5
This object contains the CMCU revision Number of the BPS
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

alaChasBpsConnectorPriorityTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2
This table contains BPS connector priority for each slot
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasBpsConnectorPriorityEntry

alaChasBpsConnectorPriorityEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1
Information about bps connector priority for each slot
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsConnectorPriorityEntry  

alaChasBpsChassisId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.1
Numbers allocated for the stack NIs as follows: - 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

alaChasBpsConnectorShelfId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.2
Bps shelf ID
Status: current Access: read-only
OBJECT-TYPE    
  AlaChasBpsShelfId  

alaChasBpsConnectorPriority 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.3
This object specifies the bps connector priority.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..8  

alaChasBpsConnectorNum 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.4
This object specifies the bps connector num.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..8)  

alaChasBpsSerialNum 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.2.1.5
This object specifies the bps serial num.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..14)  

alaChasBpsModeTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3
This table contains one row for bps config parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasBpsModeEntry

alaChasBpsModeEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3.1
Information about bps mode
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsModeEntry  

alaChasBpsMode 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.3.1.1
This object is only applicable to BPS .Value is used to specify current Mode of switch.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER single(1), full(2), notApplicable(3)  

alaChasBpsPowerSupplyTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4
This table contains BPS power supplies details
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasBpsPowerSupplyEntry

alaChasBpsPowerSupplyEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1
Information about a particular BPS power supply
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsPowerSupplyEntry  

alaChasBpsPowerSupplyShelfId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.1
BPS shelf ID
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsShelfId  

alaChasBpsPowerSupplyIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.2
This value hold BPS power power supply Index
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..5  

alaChasBpsPowerSupplyName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.3
This object hold name of BPS power supply
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..63)  

alaChasBpsPowerSupplyDescr 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.4
This object hold description of BPS power supply
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..63)  

alaChasBpsPowerSupplyModuleType 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.5
This object is unique module Type or ID from BPS entities eeprom
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..31)  

alaChasBpsPowerSupplyPartNumber 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.6
This object contains the BPS power supply Part Number
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..16)  

alaChasBpsPowerSupplyHardwareRev 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.7
The vendor-specific hardware revision string for the BPS power supplies Note that if revision information is stored internally in a non-printable (e.g., binary) format, then the agent must convert such information to a printable format, in an implementation-specific manner. If no specific hardware revision string is associated with the physical component, or this information is unknown to the agent, then this object will contain a zero-length string.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..8)  

alaChasBpsPowerSupplySerialNum 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.8
The vendor-specific serial number string for the BPS power supplies
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(0..32)  

alaChasBpsPowerSupplyMfgDate 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.9
This object contains the manufacturing date of the BPS power supplies . Its format is mmm dd yyyy : NOV 27 2012.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..11)  

alaChasBpsPowerSupplyOperStatus 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.10
Oper status of BPS power supply
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2), unknown(3)  

alaChasBpsPowerSupplyPowerProv 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.4.1.11
It corresponds to max power of BPS power supply. This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2000  

alaChasBpsTotalPowerAllocTable 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5
This table contains one row for parameters which reflect total allocation by BPS .
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlaChasBpsTotalPowerAllocEntry

alaChasBpsTotalPowerAllocEntry 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1
Information about various bps config parameters
Status: current Access: not-accessible
OBJECT-TYPE    
  AlaChasBpsTotalPowerAllocEntry  

alaChasBpsSysTotalAvailablePower 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.1
This value is only applicable to the BPS Module. It corresponds to system total power available on BPS This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..900  

alaChasBpsSysTotalAllocation 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.2
This value is only applicable to the BPS Modules. It corresponds to total system power allocated by BPS This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..900  

alaChasBpsPoeTotalAvailablePower 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.3
This value is only applicable to the BPS Modules. It corresponds to system total power available on BPS This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..6000  

alaChasBpsPoeTotalAllocation 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.14.5.1.4
This value is only applicable to the Bps Modules. It corresponds to total POE power allocated by BPS This value is in Watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..6000  

chassisTrapsObj 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13
OBJECT IDENTIFIER    

chassisTrapsStr 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.1
A Software Trouble report is sent by whatever application encountering a problem during its execution and would want to aware the user of for maintenance purpose.
Status: current Access: read-only
NOTIFICATION-TYPE    

chassisTrapsAlert 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.2
generic trap notifying something changed in the chassis whatever it's a failure or not
Status: current Access: read-only
NOTIFICATION-TYPE    

chassisTrapsStateChange 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.3
A status change was detected
Status: current Access: read-only
NOTIFICATION-TYPE    

chasTrapsBPSLessAllocSysPwr 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.4
Insufficient system power given by BPS
Status: current Access: read-only
NOTIFICATION-TYPE    

chasTrapsBPSStateChange 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.5
BPS power supplies insertion/removal trap
Status: current Access: read-only
NOTIFICATION-TYPE    

chasTrapsNiBPSFETStateChange 1.3.6.1.4.1.6486.801.1.1.1.3.1.0.6
BPS power supplies FET state change trap
Status: current Access: read-only
NOTIFICATION-TYPE    

chassisTrapsStrLevel 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.1
An enumerated value which provides the urgency level of the STR.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrLevel  

chassisTrapsStrAppID 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.2
Application Identification number
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrAppID  

chassisTrapsStrSnapID 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.3
Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrSnapID  

chassisTrapsStrfileName 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.4
Name of the source file where the fault was detected. This is given by the C ANSI macro __FILE__. The path shouldn't appear.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..19)  

chassisTrapsStrfileLineNb 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.5
Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrfileLineNb  

chassisTrapsStrErrorNb 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.6
Fault identificator. The error number identify the kind the detected fault and allow a mapping of the data contained in chassisTrapsdataInfo.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrErrorNb  

chassisTrapsStrcomments 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.7
comment text explaning the fault.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..63)  

chassisTrapsStrdataInfo 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.8
Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsStrdataInfo  

chassisTrapsObjectType 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.9
enumerated value which provide the object type involved in the alert trap.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsObjectType  

chassisTrapsObjectNumber 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.10
number defining the order of the object in the set. EX: number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. A instance of the appearance of the trap could be: failure on a module. Power supply 3.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsObjectNumber  

chassisTrapsAlertNumber 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.11
this number identify the alert among all the possible chassis alert causes.
Status: current Access: read-only
OBJECT-TYPE    
  ChassisTrapsAlertNumber  

chassisTrapsAlertDescr 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.12
description of the alert matching chassisTrapsAlertNumber
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(0..127)  

physicalIndex 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.13
The Physical index of the involved object.
Status: current Access: read-only
OBJECT-TYPE    
  PhysicalIndex  

chasTrapsNiRqstdBpsSysPower 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.14
Requested system power from os-bps
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..126  

chasTrapsNiGrantdBpsSysPower 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.15
Granted system power from os-bps
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..126  

chasTrapBPSShelfId 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.16
Granted system power from os-bps
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..3  

chasTrapsBPSPowerSupply 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.17
value which provide bps power supply involved in the State change trap
Status: current Access: read-only
OBJECT-TYPE    
  ChasTrapsBPSPowerSupply  

chasTrapsBPSEventAlert 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.18
enumerated value identifying alert
Status: current Access: read-only
OBJECT-TYPE    
  ChasTrapsBPSEventAlert  

chasTrapsBPSSystemFETChange 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.19
enumerated value which indicate Fet state
Status: current Access: read-only
OBJECT-TYPE    
  ChasTrapsBPSFetState  

chasTrapsBPSPoeFETChange 1.3.6.1.4.1.6486.801.1.1.1.3.1.1.13.20
enumerated value which indicate Fet state
Status: current Access: read-only
OBJECT-TYPE    
  ChasTrapsBPSFetState  

alcatelIND1ChassisMIBCompliance 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.2.1
Compliance statement for Chassis Supervision.
Status: current Access: read-only
MODULE-COMPLIANCE    

alcatelIND1ChassisPhysMIBCompliance 1.3.6.1.4.1.6486.801.1.1.1.1.2.2.1
Compliance statement for Chassis Supervision Physical.
Status: current Access: read-only
MODULE-COMPLIANCE    

chasControlModuleGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.1
Chassis Supervision Control Modules Group.
Status: current Access: read-only
OBJECT-GROUP    

chasControlRedundantGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.2
Chassis Supervision Redundant Control Modules Group.
Status: current Access: read-only
OBJECT-GROUP    

chasChassisGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.3
Chassis Supervision Chassis Group.
Status: current Access: read-only
OBJECT-GROUP    

chasControlReloadStatusGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.4
Chassis Supervision NI Reload Status Control Modules Group.
Status: current Access: read-only
OBJECT-GROUP    

chasGlobalControlGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.5
Chassis Supervision Global Control Modules Group.
Status: current Access: read-only
OBJECT-GROUP    

chassisNotificationGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.6
Chassis Supervision Notification Group.
Status: current Access: read-only
NOTIFICATION-GROUP    

alaChasEntPhysFanGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.7
Chassis Supervision Physical Fan Group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasNotificationObjectGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.9
Chassis Supervision Notification Object Group.
Status: current Access: read-only
OBJECT-GROUP    

chassisSupervisionRfsCommandsGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.10
Chassis Supervision RFS Command Group.
Status: current Access: read-only
OBJECT-GROUP    

chasSupervisionCmmCertifiedEntryGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.11
Information about Cmm Certified Group.
Status: current Access: read-only
OBJECT-GROUP    

chasSupervisionFlashMemEntryGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.12
The systems flash memory information group.
Status: current Access: read-only
OBJECT-GROUP    

chasSupervisionRfsDfEntryGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.13
Information about RfsDf file system group.
Status: current Access: read-only
OBJECT-GROUP    

chasSupervisionRfsLsEntryGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.14
Information about a RfsLs file group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasBpsFwGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.15
Information about BPS FW group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasBpsConnectorPriorityGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.16
Information about BPS Connector Priority group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasBpsModeGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.17
Information about BPS Mode group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasBpsPowerSupplyGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.18
BPS Power Supply group.
Status: current Access: read-only
OBJECT-GROUP    

alaChasBpsTotalPowerAllocGroup 1.3.6.1.4.1.6486.801.1.1.1.3.1.2.1.19
BPS Total Power Alloc group.
Status: current Access: read-only
OBJECT-GROUP    

chasEntPhysicalGroup 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.1
Chassis (inclosure) Entity Physical Group.
Status: current Access: read-only
OBJECT-GROUP    

chassisPhysNotificationGroup 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.2
Chassis Supervision Physical Notification Group.
Status: current Access: read-only
NOTIFICATION-GROUP    

chassisTemperatureGroup 1.3.6.1.4.1.6486.801.1.1.1.1.2.1.3
Chassis Supervision Temprature Group.
Status: current Access: read-only
OBJECT-GROUP