ADMIN-ALTEON-AC-vADC-MIB

File: ADMIN-ALTEON-AC-vADC-MIB.mib (64967 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC ALTEON-ROOT-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 Gauge32 TimeTicks
IpAddress DisplayString PhysAddress
virt-admin

Defined Types

VADCCurCfgTableEntry  
SEQUENCE    
  vADCCurCfgVADCId INTEGER
  vADCCurCfgVlanId OCTET STRING
  vADCCurCfgName DisplayString
  vADCCurCfgCU INTEGER
  vADCCurCfgLimit INTEGER
  vADCCurCfgState INTEGER
  vADCCurCfgFeatGlobal INTEGER
  vADCCurCfgFeatBWM INTEGER
  vADCCurCfgFeatITM INTEGER
  vADCCurCfgFeatADOS INTEGER
  vADCCurCfgFeatLLB INTEGER
  vADCCurCfgSslLimit INTEGER
  vADCCurCfgCompLimit INTEGER
  vADCCurResetImageVersion DisplayString
  vADCCurSyncPeerSwitch INTEGER

VADCNewCfgTableEntry  
SEQUENCE    
  vADCNewCfgVADCId INTEGER
  vADCNewCfgVlanId OCTET STRING
  vADCNewCfgAddVlan INTEGER
  vADCNewCfgRemoveVlan INTEGER
  vADCNewCfgName DisplayString
  vADCNewCfgCU INTEGER
  vADCNewCfgLimit INTEGER
  vADCNewCfgState INTEGER
  vADCNewCfgDelete INTEGER
  vADCNewCfgFeatGlobal INTEGER
  vADCNewCfgFeatBWM INTEGER
  vADCNewCfgFeatITM INTEGER
  vADCNewCfgFeatADOS INTEGER
  vADCNewCfgFeatLLB INTEGER
  vADCNewCfgSslLimit INTEGER
  vADCNewCfgCompLimit INTEGER
  vADCNewResetImageVersion DisplayString
  vADCNewSyncPeerSwitch INTEGER

VADCCurCfgSysTableEntry  
SEQUENCE    
  vADCCurCfgSysMmgmtAddr IpAddress
  vADCCurCfgSysMmgmtMask IpAddress
  vADCCurCfgSysMmgmtGw IpAddress
  vADCCurCfgSysMmgmtState INTEGER
  vADCCurCfgSysPeerAddr IpAddress
  vADCCurCfgSysPeerMask IpAddress
  vADCCurCfgSysPeerGw IpAddress
  vADCCurCfgSysHttpsState INTEGER
  vADCCurCfgSysSshState INTEGER
  vADCCurCfgSysHttpState INTEGER
  vADCCurCfgSysSnmpState INTEGER
  vADCCurCfgSysSyslogState INTEGER
  vADCCurCfgSysRadiusState INTEGER
  vADCCurCfgSysTacacsState INTEGER
  vADCCurCfgSysIdleState INTEGER
  vADCCurCfgSysSmtpState INTEGER
  vADCCurCfgSyslogDelegation INTEGER
  vADCCurCfgRadiusDelegation INTEGER
  vADCCurCfgTacacsDelegation INTEGER
  vADCCurCfgSmtpDelegation INTEGER
  vADCCurCfgSysMmgmtIpv6Addr DisplayString
  vADCCurCfgSysMmgmtIpv6PrefixLen INTEGER
  vADCCurCfgSysMmgmtIpv6Gateway DisplayString
  vADCCurCfgSysPeerIpv6Addr DisplayString
  vADCCurCfgSysPeerIpv6PrefixLen INTEGER
  vADCCurCfgSysPeerIpv6Gateway DisplayString
  vADCCurCfgSysTnetState INTEGER
  vADCCurCfgSysHaId INTEGER
  vADCCurCfgSysPeerId INTEGER
  vADCCurCfgSysVADCId INTEGER
  vADCCurCfgIdleDelegation INTEGER
  vADCCurCfgSysMmgmtDelegation INTEGER
  vADCCurCfgSysPeerName DisplayString

VADCNewCfgSysTableEntry  
SEQUENCE    
  vADCNewCfgSysMmgmtAddr IpAddress
  vADCNewCfgSysMmgmtMask IpAddress
  vADCNewCfgSysMmgmtGw IpAddress
  vADCNewCfgSysMmgmtState INTEGER
  vADCNewCfgSysPeerAddr IpAddress
  vADCNewCfgSysPeerMask IpAddress
  vADCNewCfgSysPeerGw IpAddress
  vADCNewCfgSysHttpsState INTEGER
  vADCNewCfgSysSshState INTEGER
  vADCNewCfgSysHttpState INTEGER
  vADCNewCfgSysSnmpState INTEGER
  vADCNewCfgSysSyslogState INTEGER
  vADCNewCfgSysRadiusState INTEGER
  vADCNewCfgSysTacacsState INTEGER
  vADCNewCfgSysIdleState INTEGER
  vADCNewCfgSysSmtpState INTEGER
  vADCNewCfgSyslogDelegation INTEGER
  vADCNewCfgRadiusDelegation INTEGER
  vADCNewCfgTacacsDelegation INTEGER
  vADCNewCfgSmtpDelegation INTEGER
  vADCNewCfgSysMmgmtIpv6Addr DisplayString
  vADCNewCfgSysMmgmtIpv6PrefixLen INTEGER
  vADCNewCfgSysMmgmtIpv6Gateway DisplayString
  vADCNewCfgSysPeerIpv6Addr DisplayString
  vADCNewCfgSysPeerIpv6PrefixLen INTEGER
  vADCNewCfgSysPeerIpv6Gateway DisplayString
  vADCNewCfgSysTnetState INTEGER
  vADCNewCfgSysHaId INTEGER
  vADCNewCfgSysPeerId INTEGER
  vADCNewCfgSysVADCId INTEGER
  vADCNewCfgIdleDelegation INTEGER
  vADCNewCfgSysMmgmtDelegation INTEGER
  vADCNewCfgSysPeerName DisplayString

VADCCurCfgNetTableEntry  
SEQUENCE    
  vADCCurCfgNetId INTEGER
  vADCCurCfgNetVlanId INTEGER
  vADCCurCfgNetIPver INTEGER
  vADCCurCfgNetIPBegin IpAddress
  vADCCurCfgNetMask IpAddress
  vADCCurCfgNetIPEnd IpAddress
  vADCCurCfgNetIPv6Begin DisplayString
  vADCCurCfgNetPrefix INTEGER
  vADCCurCfgNetIPv6End DisplayString
  vADCCurCfgNetVADCId INTEGER

VADCNewCfgNetTableEntry  
SEQUENCE    
  vADCNewCfgNetId INTEGER
  vADCNewCfgNetVlanId INTEGER
  vADCNewCfgNetIPver INTEGER
  vADCNewCfgNetIPBegin IpAddress
  vADCNewCfgNetMask IpAddress
  vADCNewCfgNetIPEnd IpAddress
  vADCNewCfgNetRemId INTEGER
  vADCNewCfgNetIPv6Begin DisplayString
  vADCNewCfgNetPrefix INTEGER
  vADCNewCfgNetIPv6End DisplayString
  vADCNewCfgNetVADCId INTEGER

VADCUserCurCfgTableEntry  
SEQUENCE    
  vADCUserCurCfgVADCId Integer32
  vADCUserCurCfgUId Integer32
  vADCUserCurCos INTEGER
  vADCUserCurCfgName DisplayString
  vADCUserCurCfgAdminPswd DisplayString
  vADCUserCurCfgPswd DisplayString
  vADCUserCurCfgConfPswd DisplayString
  vADCUserCurCfgBackdoor INTEGER
  vADCUserCurCfgCrtMng INTEGER
  vADCUserCurCfgState INTEGER

VADCUserNewCfgTableEntry  
SEQUENCE    
  vADCUserNewCfgVADCId Integer32
  vADCUserNewCfgUId Integer32
  vADCUserNewCos INTEGER
  vADCUserNewCfgName DisplayString
  vADCUserNewCfgAdminPswd DisplayString
  vADCUserNewCfgPswd DisplayString
  vADCUserNewCfgConfPswd DisplayString
  vADCUserNewCfgBackdoor INTEGER
  vADCUserNewCfgCrtMng INTEGER
  vADCUserNewCfgState INTEGER
  vADCUserNewCfgDelete INTEGER

VADCUsersPswdTableEntry  
SEQUENCE    
  vADCUsersVADCId Integer32
  vADCAccessUsrPasswd DisplayString
  vADCAccessSlbOperPasswd DisplayString
  vADCAccessL4OperPasswd DisplayString
  vADCAccessOperPasswd DisplayString
  vADCAccessSlbAdminPasswd DisplayString
  vADCAccessL4AdminPasswd DisplayString
  vADCAccessAdminPasswd DisplayString
  vADCAccessAdminNewPasswd DisplayString
  vADCAccessAdminConfNewPasswd DisplayString

VADCInfoTableEntry  
SEQUENCE    
  vADCInfoId INTEGER
  vADCInfoName DisplayString
  vADCInfoStatus INTEGER
  vADCInfoVRRPStatus INTEGER
  vADCInfoCU INTEGER
  vADCInfoThroughput INTEGER
  vADCInfoLimit INTEGER
  vADCInfoSPcpu INTEGER
  vADCInfoMPcpu INTEGER
  vADCInfoCUMbit Integer32
  vADCInfoUpTime DisplayString

VADCBootTableEntry  
SEQUENCE    
  vADCBootVADCId INTEGER
  vADCBootAction INTEGER

VADCStatsAccelResourceTableEntry  
SEQUENCE    
  vADCIndex INTEGER
  vADCName DisplayString
  vADCStatsCompLimit INTEGER
  vADCStatsCompUtil INTEGER
  vADCStatsSSLLimit INTEGER
  vADCStatsSSLUtil INTEGER

VADCMemStatsTableEntry  
SEQUENCE    
  vADCMemStatsIndex INTEGER
  vADCMemStatsName DisplayString
  vADCMemStatsCurrentMemory INTEGER
  vADCMemStatsHiWaterMark INTEGER

Defined Values

adminvADC 1.3.6.1.4.1.1872.2.6.1
The MIB module for the Alteon OS AdminContext configuration, statistics and information .
MODULE-IDENTITY    

adminvADCConfigs 1.3.6.1.4.1.1872.2.6.1.1
OBJECT IDENTIFIER    

adminvADCInfo 1.3.6.1.4.1.1872.2.6.1.2
OBJECT IDENTIFIER    

adminvADCBoot 1.3.6.1.4.1.1872.2.6.1.3
OBJECT IDENTIFIER    

adminvADCStats 1.3.6.1.4.1.1872.2.6.1.4
OBJECT IDENTIFIER    

vADCConfig 1.3.6.1.4.1.1872.2.6.1.1.1
OBJECT IDENTIFIER    

vADCInfo 1.3.6.1.4.1.1872.2.6.1.2.1
OBJECT IDENTIFIER    

vADCBoot 1.3.6.1.4.1.1872.2.6.1.3.1
OBJECT IDENTIFIER    

vADCStat 1.3.6.1.4.1.1872.2.6.1.4.1
OBJECT IDENTIFIER    

vADCMaxVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.1
The maximum allowed vADC ID.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vADCMaxCU 1.3.6.1.4.1.1872.2.6.1.1.1.2
The maximum allowed Capacity Units.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vADCCurCfgTable 1.3.6.1.4.1.1872.2.6.1.1.1.3
The table of vADC configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCCurCfgTableEntry

vADCCurCfgTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.3.1
A row in the vADC configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCCurCfgTableEntry  

vADCCurCfgVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.1
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCCurCfgVlanId 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.2
The vlans list for vADCs. The vlans are presented in bitmap format. This string displays vlan number from 1 to 4090. in receiving order: OCTET 1 OCTET 2 ..... xxxxxxxx xxxxxxxx ..... || || |_ vlan 8 || || || ||___ vlan 7 || |____ vlan 6 || . . . ||_________ vlan 1 |__________ Reserved where x : 1 - The represented vlan applied to the vADC. 0 - The represented vlan not applied to the vADC.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

vADCCurCfgName 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.3
The vADC name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

vADCCurCfgCU 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.4
Default vADC Capacity Units.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCCurCfgLimit 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.5
The vADC Throughput value in Mbps.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..20000  

vADCCurCfgState 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.6
Enable or disable a vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgFeatGlobal 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.7
Enable or disable of global feature license for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgFeatBWM 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.8
Enable or disable of BWM feature license for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgFeatITM 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.9
Enable or disable of ITM feature license for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgFeatADOS 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.10
Enable or disable of ADoS feature license for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgFeatLLB 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.11
Enable or disable of LLB feature license for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSslLimit 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.12
The maximum SSL throughput Limit allowed for vADC in CPSs. The SSL Throughput value should be in multiples of 10 CPSs blocks.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..60000  

vADCCurCfgCompLimit 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.13
The maximum compression throughput Limit allowed for vADC in Mbps. The compression Throughput value should be in multiples of 10 Mbps blocks.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7500  

vADCCurResetImageVersion 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.14
Image version to use on next reset
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCCurSyncPeerSwitch 1.3.6.1.4.1.1872.2.6.1.1.1.3.1.15
The ID of the Peer Switch (agSysPeerCurCfgIndex), with which the vADC in question is associated (values 1..5). Value 0 means no association.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..5  

vADCNewCfgTable 1.3.6.1.4.1.1872.2.6.1.1.1.4
The table of vADC configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCNewCfgTableEntry

vADCNewCfgTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.4.1
A row in the vADC configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCNewCfgTableEntry  

vADCNewCfgVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.1
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCNewCfgVlanId 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.2
The vlan list in the vADC in bitmap format.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING  

vADCNewCfgAddVlan 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.3
The vlan to be added to the specified vADC. A '0' value is returned when read.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..4090  

vADCNewCfgRemoveVlan 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.4
The vlan to be removed from the specified vADC. A '0' value is returned when read.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..4090  

vADCNewCfgName 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.5
The VADC name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..31)  

vADCNewCfgCU 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.6
The vADC Capacity Units.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER  

vADCNewCfgLimit 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.7
The throughput Limit allowed for vADC in Mbps.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..20000  

vADCNewCfgState 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.8
Enable or disable a VADC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgDelete 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.9
This is an action object to create or delete a vADC. other(1) is returned always when read. The following values are writable: delete(2)...to delete a VADC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER other(1), delete(2)  

vADCNewCfgFeatGlobal 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.10
Enable or disable of Global feature license for vADC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgFeatBWM 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.11
Enable or disable of BWM feature license for vADC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgFeatITM 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.12
Enable or disable of ITM feature license for vADC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgFeatADOS 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.13
Enable or disable of ADoS feature license for vADC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgFeatLLB 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.14
Enable or disable of LLB feature license for vADC.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSslLimit 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.15
The maximum SSL throughput Limit allowed for vADC in CPSs. The SSL Throughput value should be in multiples of 10 CPSs blocks.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..60000  

vADCNewCfgCompLimit 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.16
The maximum compression throughput Limit allowed for vADC in Mbps. The compression Throughput value should be in multiples of 10 Mbps blocks.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..7500  

vADCNewResetImageVersion 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.17
Image version to use on next reset
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCNewSyncPeerSwitch 1.3.6.1.4.1.1872.2.6.1.1.1.4.1.18
The ID of the Peer Switch (agSysPeerNewCfgIndex), with which the vADC in question is associated (values 1..5). Value 0 means no association.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..5  

vADCCurCfgSysTable 1.3.6.1.4.1.1872.2.6.1.1.1.5
The table of vADC System services configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCCurCfgSysTableEntry

vADCCurCfgSysTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.5.1
A row in the vADC System services configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCCurCfgSysTableEntry  

vADCCurCfgSysMmgmtAddr 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.1
The vADC system services management IP address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysMmgmtMask 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.2
The vADC system services management IP subnet mask address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysMmgmtGw 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.3
The vADC system services management IP gateway address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysMmgmtState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.4
Enable or disable a vADC management system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysPeerAddr 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.5
The vADC system services peer IP address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysPeerMask 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.6
The vADC system services peer IP subnet mask address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysPeerGw 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.7
The vADC system services peer IP gateway address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgSysHttpsState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.8
Enable or disable a vADC https system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysSshState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.9
Enable or disable a vADC ssh system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysHttpState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.10
Enable or disable a vADC http system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysSnmpState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.11
Enable or disable a vADC snmp system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysSyslogState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.12
Enable or disable a vADC syslog system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysRadiusState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.13
Enable or disable a vADC radius system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysTacacsState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.14
Enable or disable a vADC tacacs system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysIdleState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.15
Enable or disable a vADC idle system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysSmtpState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.16
Enable or disable a vADC smtp system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSyslogDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.17
Enable or disable delegation for vADC syslog system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgRadiusDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.18
Enable or disable delegation for vADC radius system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgTacacsDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.19
Enable or disable delegation for vADC tacacs system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSmtpDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.20
Enable or disable delegation for vADC smtp system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysMmgmtIpv6Addr 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.21
The IPV6 address of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgSysMmgmtIpv6PrefixLen 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.22
The IPV6 prefix length of the vADC management port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..128  

vADCCurCfgSysMmgmtIpv6Gateway 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.23
The IPV6 Gateway of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgSysPeerIpv6Addr 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.24
The peer IPV6 Address of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgSysPeerIpv6PrefixLen 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.25
The vADC system services peer IPv6 prefix length.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..128  

vADCCurCfgSysPeerIpv6Gateway 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.26
The Peer IPV6 gateway of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgSysTnetState 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.27
Enable or disable vADC Telnet access.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysHaId 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.28
HA ID for vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..64  

vADCCurCfgSysPeerId 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.29
Peer ID for vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..28  

vADCCurCfgSysVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.30
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCCurCfgIdleDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.31
Enable or disable delegation for vADC idle timeout system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysMmgmtDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.32
Enable or disable delegation for vADC management system service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCCurCfgSysPeerName 1.3.6.1.4.1.1872.2.6.1.1.1.5.1.33
The vADC system services peer Name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

vADCNewCfgSysTable 1.3.6.1.4.1.1872.2.6.1.1.1.6
The table of vADC System services configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCNewCfgSysTableEntry

vADCNewCfgSysTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.6.1
A row in the vADC system services configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCNewCfgSysTableEntry  

vADCNewCfgSysMmgmtAddr 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.1
The vADC system services management IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysMmgmtMask 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.2
The vADC system services management IP subnet mask address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysMmgmtGw 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.3
The vADC system services management IP gateway address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysMmgmtState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.4
Enable or disable a vADC management system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysPeerAddr 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.5
The vADC system services peer IP address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysPeerMask 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.6
The vADC system services peer IP subnet mask address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysPeerGw 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.7
The vADC system services peer IP gateway address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgSysHttpsState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.8
Enable or disable a vADC https system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysSshState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.9
Enable or disable a vADC ssh system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysHttpState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.10
Enable or disable a vADC http system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysSnmpState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.11
Enable or disable a vADC snmp system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysSyslogState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.12
Enable or disable a vADC syslog system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysRadiusState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.13
Enable or disable a vADC radius system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysTacacsState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.14
Enable or disable a vADC tacacs system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysIdleState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.15
Enable or disable a vADC idle system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysSmtpState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.16
Enable or disable a vADC smtp system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSyslogDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.17
Enable or disable delegation for vADC syslog system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgRadiusDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.18
Enable or disable delegation for vADC radius system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgTacacsDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.19
Enable or disable delegation for vADC tacacs system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSmtpDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.20
Enable or disable delegation for vADC smtp system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysMmgmtIpv6Addr 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.21
The IPV6 address of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgSysMmgmtIpv6PrefixLen 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.22
The IPV6 prefix length of the vADC management port.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..128  

vADCNewCfgSysMmgmtIpv6Gateway 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.23
The IPV6 Gateway of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgSysPeerIpv6Addr 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.24
The peer IPV6 Address of the vADC system services. Addrvess should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgSysPeerIpv6PrefixLen 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.25
The vADC system services peer IPv6 prefix length.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..128  

vADCNewCfgSysPeerIpv6Gateway 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.26
The Peer IPV6 gateway of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgSysTnetState 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.27
Enable or disable vADC Telnet access.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysHaId 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.28
HA ID for vADC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..64  

vADCNewCfgSysPeerId 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.29
Peer ID for vADC
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..28  

vADCNewCfgSysVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.30
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCNewCfgIdleDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.31
Enable or disable delegation for vADC idle timeout system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysMmgmtDelegation 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.32
Enable or disable delegation for vADC management system service.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCNewCfgSysPeerName 1.3.6.1.4.1.1872.2.6.1.1.1.6.1.33
The vADC system services peer Name.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..31)  

vADCCurCfgNetTable 1.3.6.1.4.1.1872.2.6.1.1.1.7
The table of vADC configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCCurCfgNetTableEntry

vADCCurCfgNetTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.7.1
A row in the VADC allowed network configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCCurCfgNetTableEntry  

vADCCurCfgNetId 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.1
The vADC allowed network identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

vADCCurCfgNetVlanId 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.2
The vADC allowed network vlan identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4096  

vADCCurCfgNetIPver 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.3
The vADC allowed network ip version.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ipv4(4), ipv6(6)  

vADCCurCfgNetIPBegin 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.4
The vADC allowed network subnet begining IP address for shared vlan.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgNetMask 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.5
The vADC allowed network subnet address.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgNetIPEnd 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.6
The vADC allowed network subnet end IP address for shared vlan.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

vADCCurCfgNetIPv6Begin 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.7
The IPv6 begining address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgNetPrefix 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.8
The prefix length associated with this IP address .
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..128  

vADCCurCfgNetIPv6End 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.9
The IPv6 end address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCCurCfgNetVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.7.1.10
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCNewCfgNetTable 1.3.6.1.4.1.1872.2.6.1.1.1.8
The table of vADC allowed network new configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCNewCfgNetTableEntry

vADCNewCfgNetTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.8.1
A row in the VADC allowed network configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCNewCfgNetTableEntry  

vADCNewCfgNetId 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.1
The vADC allowed network identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..1024  

vADCNewCfgNetVlanId 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.2
The new vADC allowed network vlan identifier.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..4096  

vADCNewCfgNetIPver 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.3
The new vADC allowed network ip version.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ipv4(4), ipv6(6)  

vADCNewCfgNetIPBegin 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.4
The vADC allowed network subnet begining IP address for shared vlan or subnet IP address for non shared vlan.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgNetMask 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.5
The vADC allowed network subnet address.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgNetIPEnd 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.6
The vADC allowed network subnet end IP address for shared vlan.
Status: current Access: read-create
OBJECT-TYPE    
  IpAddress  

vADCNewCfgNetRemId 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.7
This is an action object to create or delete a vADC allowed network. other(1) is returned always when read. The following values are writable: delete(2)...to delete a vADC allowed network
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER other(1), delete(2)  

vADCNewCfgNetIPv6Begin 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.8
The IPv6 begining address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgNetPrefix 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.9
The prefix length associated with this IP address .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..128  

vADCNewCfgNetIPv6End 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.10
The IPv6 end address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..40)  

vADCNewCfgNetVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.8.1.11
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCAccessUser 1.3.6.1.4.1.1872.2.6.1.1.1.9
OBJECT IDENTIFIER    

vADCAccessUid 1.3.6.1.4.1.1872.2.6.1.1.1.9.1
OBJECT IDENTIFIER    

vADCUserCurCfgTable 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1
vADC Current User configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCUserCurCfgTableEntry

vADCUserCurCfgTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1
A row in the VADC User Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCUserCurCfgTableEntry  

vADCUserCurCfgVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.1
The VADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vADCUserCurCfgUId 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.2
The User identifier.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vADCUserCurCos 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.3
The user class of service.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER user(0), l3Oper(1), slboper(2), slbview(3), crtadmin(4), l4oper(5), oper(6), l3admin(7), slbadmin(8), l4admin(9), admin(10)  

vADCUserCurCfgName 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.4
The user name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

vADCUserCurCfgAdminPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.5
The character string representing the admin password.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserCurCfgPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.6
The character string representing the user password.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserCurCfgConfPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.7
The character string is used to confirm the user password.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserCurCfgBackdoor 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.8
Enable or disable vadc user backdoor access.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserCurCfgCrtMng 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.9
Enable or disable certificate management permissions.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserCurCfgState 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.1.1.10
Enable or disable a user.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserNewCfgTable 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2
vADC New User configuration Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCUserNewCfgTableEntry

vADCUserNewCfgTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1
A row in the VADC User Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCUserNewCfgTableEntry  

vADCUserNewCfgVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.1
The VADC identifier.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vADCUserNewCfgUId 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.2
The User identifier.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vADCUserNewCos 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.3
The user class of service.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER user(0), l3oper(1), slboper(2), slbview(3), crtadmin(4), l4oper(5), oper(6), l3admin(7), slbadmin(8), l4admin(9), admin(10)  

vADCUserNewCfgName 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.4
The user name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..8)  

vADCUserNewCfgAdminPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.5
The character string representing the admin password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserNewCfgPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.6
The character string representing the user password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserNewCfgConfPswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.7
The character string is used to confirm the user password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCUserNewCfgBackdoor 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.8
Enable or disable vadc user backdoor access.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserNewCfgCrtMng 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.9
Enable or disable certificate management permissions.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserNewCfgState 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.10
Enable or disable a user.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(2), disabled(3)  

vADCUserNewCfgDelete 1.3.6.1.4.1.1872.2.6.1.1.1.9.1.2.1.11
This is an action object to create or delete a User. other(1) is returned always when read. The following values are writable: delete(2)...to delete a User
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER other(1), delete(2)  

vADCUsersPswdTable 1.3.6.1.4.1.1872.2.6.1.1.1.9.2
vADC Users Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCUsersPswdTableEntry

vADCUsersPswdTableEntry 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1
A row in the VADC User Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCUsersPswdTableEntry  

vADCUsersVADCId 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.1
The VADC identifier.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

vADCAccessUsrPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.2
The character string representing the user password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessSlbOperPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.3
The character string representing the SLB operator(slboper) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessL4OperPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.4
The character string representing the L4 operator(l4oper) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessOperPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.5
The character string representing the Operator(oper) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessSlbAdminPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.6
The character string representing the Slb Admin (slbadmin) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessL4AdminPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.7
The character string representing the L4 Admin(l4admin) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessAdminPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.8
The character string representing the current Administrator(admin) password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessAdminNewPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.9
The character string representing the Administrator(admin) New password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCAccessAdminConfNewPasswd 1.3.6.1.4.1.1872.2.6.1.1.1.9.2.1.10
The character string is used to confirm the Administrator(admin) New password.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

vADCInfoAvailableCU 1.3.6.1.4.1.1872.2.6.1.2.1.1
The available vADC Capacity Units.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..28  

vADCInfoAvailableThruput 1.3.6.1.4.1.1872.2.6.1.2.1.2
The available throughput in Mbps.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..20000  

vADCInfoTable 1.3.6.1.4.1.1872.2.6.1.2.1.3
The table of vADC information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCInfoTableEntry

vADCInfoTableEntry 1.3.6.1.4.1.1872.2.6.1.2.1.3.1
Information about a particular vADC.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCInfoTableEntry  

vADCInfoId 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.1
The VADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..28  

vADCInfoName 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.2
The vADC name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..18)  

vADCInfoStatus 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.3
vADC state information.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), init(1), running(2), down(3), stopping(4), restarting(5), querying(6)  

vADCInfoVRRPStatus 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.4
The vADC VRRP state information
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER init(1), master(2), backup(3), holdoff(4), off(5), active(6), standby(7)  

vADCInfoCU 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.5
The vADC Capacity Units.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..28  

vADCInfoThroughput 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.6
The Maximum throughput allowed for vADC in Mbps.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..20000  

vADCInfoLimit 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.7
The throughput Limit for vADC in Mbps.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..20000  

vADCInfoSPcpu 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.8
The percentage of SP CPU usage for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

vADCInfoMPcpu 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.9
The percentage of MP CPU usage for vADC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

vADCInfoCUMbit 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.10
The value of CU in Mbit.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vADCInfoUpTime 1.3.6.1.4.1.1872.2.6.1.2.1.3.1.11
The vADC uptime information.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vADCInfoConfigChangeTime 1.3.6.1.4.1.1872.2.6.1.2.1.4
The value of sysUpTime at the last vADC configuration change.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

vADCBootTable 1.3.6.1.4.1.1872.2.6.1.3.1.1
The table of vADC Boot Table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCBootTableEntry

vADCBootTableEntry 1.3.6.1.4.1.1872.2.6.1.3.1.1.1
Information about a particular vADC.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCBootTableEntry  

vADCBootVADCId 1.3.6.1.4.1.1872.2.6.1.3.1.1.1.1
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..28  

vADCBootAction 1.3.6.1.4.1.1872.2.6.1.3.1.1.1.2
This object may contain the following values: none(1) This action does not reboot vADC. Setting this object to none(1) has no effect. reset(2) This action will reboot vADC without apply/save the unapplied/unsaved configuration changes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), reset(2)  

vADCStatsAccelResourceTable 1.3.6.1.4.1.1872.2.6.1.4.1.1
The table of vADC vADCStatsAccelResourceTableEntries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCStatsAccelResourceTableEntry

vADCStatsAccelResourceTableEntry 1.3.6.1.4.1.1872.2.6.1.4.1.1.1
A row in the vADC accelarration resources statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCStatsAccelResourceTableEntry  

vADCIndex 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.1
The vADC identifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCName 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.2
The vADC name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vADCStatsCompLimit 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.3
the compression limit allocated to vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCStatsCompUtil 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.4
the compression limit utilized by vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCStatsSSLLimit 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.5
the SSL limit allocated to vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCStatsSSLUtil 1.3.6.1.4.1.1872.2.6.1.4.1.1.1.6
the SSL limit utilized by vADC
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCMemStatsTable 1.3.6.1.4.1.1872.2.6.1.4.1.2
The table of vADC vADCMemStatsTableEntries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VADCMemStatsTableEntry

vADCMemStatsTableEntry 1.3.6.1.4.1.1872.2.6.1.4.1.2.1
A row in the vADC Memory table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VADCMemStatsTableEntry  

vADCMemStatsIndex 1.3.6.1.4.1.1872.2.6.1.4.1.2.1.1
The vADC index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCMemStatsName 1.3.6.1.4.1.1872.2.6.1.4.1.2.1.2
The vADC name.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vADCMemStatsCurrentMemory 1.3.6.1.4.1.1872.2.6.1.4.1.2.1.3
The current memory of vADC in KiloBytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

vADCMemStatsHiWaterMark 1.3.6.1.4.1.1872.2.6.1.4.1.2.1.4
The high watermark of vADC in KiloBytes.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER