AC-PM-SS7-MIB

File: AC-PM-SS7-MIB.mib (80558 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC1155-SMI
SNMP-FRAMEWORK-MIB AUDIOCODES-TYPES-MIB

Imported symbols

Counter32 Gauge32 OBJECT-TYPE
MODULE-IDENTITY TAddress DisplayString
DateAndTime TEXTUAL-CONVENTION IpAddress
Unsigned32 Integer32 enterprises
SnmpAdminString audioCodes acRegistrations
acGeneric acProducts acBoardMibs
acPerformance

Defined Types

AcPMSS7TxMSUEntry  
SEQUENCE    
  acPMSS7TxMSULink Unsigned32
  acPMSS7TxMSUInterval Unsigned32
  acPMSS7TxMSUVal Counter32
  acPMSS7TxMSUTotal Integer32

AcPMSS7RxMSUEntry  
SEQUENCE    
  acPMSS7RxMSULink Unsigned32
  acPMSS7RxMSUInterval Unsigned32
  acPMSS7RxMSUVal Counter32
  acPMSS7RxMSUTotal Integer32

AcPMSS7TxLSSUEntry  
SEQUENCE    
  acPMSS7TxLSSULink Unsigned32
  acPMSS7TxLSSUInterval Unsigned32
  acPMSS7TxLSSUVal Counter32
  acPMSS7TxLSSUTotal Integer32

AcPMSS7RxLSSUEntry  
SEQUENCE    
  acPMSS7RxLSSULink Unsigned32
  acPMSS7RxLSSUInterval Unsigned32
  acPMSS7RxLSSUVal Counter32
  acPMSS7RxLSSUTotal Integer32

AcPMSS7TxFISUEntry  
SEQUENCE    
  acPMSS7TxFISULink Unsigned32
  acPMSS7TxFISUInterval Unsigned32
  acPMSS7TxFISUVal Counter32
  acPMSS7TxFISUTotal Integer32

AcPMSS7RxFISUEntry  
SEQUENCE    
  acPMSS7RxFISULink Unsigned32
  acPMSS7RxFISUInterval Unsigned32
  acPMSS7RxFISUVal Counter32
  acPMSS7RxFISUTotal Integer32

AcPMSS7TxSignalUnitsEntry  
SEQUENCE    
  acPMSS7TxSignalUnitsLink Unsigned32
  acPMSS7TxSignalUnitsInterval Unsigned32
  acPMSS7TxSignalUnitsVal Counter32
  acPMSS7TxSignalUnitsTotal Integer32

AcPMSS7RxSignalUnitsEntry  
SEQUENCE    
  acPMSS7RxSignalUnitsLink Unsigned32
  acPMSS7RxSignalUnitsInterval Unsigned32
  acPMSS7RxSignalUnitsVal Counter32
  acPMSS7RxSignalUnitsTotal Integer32

AcPMSS7TxOctetsEntry  
SEQUENCE    
  acPMSS7TxOctetsLink Unsigned32
  acPMSS7TxOctetsInterval Unsigned32
  acPMSS7TxOctetsVal Counter32
  acPMSS7TxOctetsTotal Integer32

AcPMSS7RxOctetsEntry  
SEQUENCE    
  acPMSS7RxOctetsLink Unsigned32
  acPMSS7RxOctetsInterval Unsigned32
  acPMSS7RxOctetsVal Counter32
  acPMSS7RxOctetsTotal Integer32

AcPMSS7MTP2NoAckRxEntry  
SEQUENCE    
  acPMSS7MTP2NoAckRxLink Unsigned32
  acPMSS7MTP2NoAckRxInterval Unsigned32
  acPMSS7MTP2NoAckRxVal Counter32
  acPMSS7MTP2NoAckRxTotal Integer32

AcPMSS7DiscMSUEntry  
SEQUENCE    
  acPMSS7DiscMSULink Unsigned32
  acPMSS7DiscMSUInterval Unsigned32
  acPMSS7DiscMSUVal Counter32
  acPMSS7DiscMSUTotal Integer32

AcPMSS7InServiceEntry  
SEQUENCE    
  acPMSS7InServiceLink Unsigned32
  acPMSS7InServiceInterval Unsigned32
  acPMSS7InServiceVal Gauge32
  acPMSS7InServiceTimeAboveHighThreshold Integer32
  acPMSS7InServiceTimeBetweenThresholds Integer32

AcPMSS7OutOfServiceEntry  
SEQUENCE    
  acPMSS7OutOfServiceLink Unsigned32
  acPMSS7OutOfServiceInterval Unsigned32
  acPMSS7OutOfServiceVal Gauge32
  acPMSS7OutOfServiceTimeAboveHighThreshold Integer32
  acPMSS7OutOfServiceTimeBetweenThresholds Integer32

AcPMSS7SN0LSOutOfServiceEntry  
SEQUENCE    
  acPMSS7SN0LSOutOfServiceLinkSet Unsigned32
  acPMSS7SN0LSOutOfServiceInterval Unsigned32
  acPMSS7SN0LSOutOfServiceVal Gauge32
  acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold Integer32
  acPMSS7SN0LSOutOfServiceTimeBetweenThresholds Integer32

AcPMSS7SN1LSOutOfServiceEntry  
SEQUENCE    
  acPMSS7SN1LSOutOfServiceLinkSet Unsigned32
  acPMSS7SN1LSOutOfServiceInterval Unsigned32
  acPMSS7SN1LSOutOfServiceVal Gauge32
  acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold Integer32
  acPMSS7SN1LSOutOfServiceTimeBetweenThresholds Integer32

AcPMSS7TxMTP3OctetsEntry  
SEQUENCE    
  acPMSS7TxMTP3OctetsSN Unsigned32
  acPMSS7TxMTP3OctetsInterval Unsigned32
  acPMSS7TxMTP3OctetsVal Counter32
  acPMSS7TxMTP3OctetsTotal Integer32

AcPMSS7RxMTP3OctetsEntry  
SEQUENCE    
  acPMSS7RxMTP3OctetsSN Unsigned32
  acPMSS7RxMTP3OctetsInterval Unsigned32
  acPMSS7RxMTP3OctetsVal Counter32
  acPMSS7RxMTP3OctetsTotal Integer32

AcPMSS7TxMTP3MSUEntry  
SEQUENCE    
  acPMSS7TxMTP3MSUSN Unsigned32
  acPMSS7TxMTP3MSUInterval Unsigned32
  acPMSS7TxMTP3MSUVal Counter32
  acPMSS7TxMTP3MSUTotal Integer32

AcPMSS7RxMTP3MSUEntry  
SEQUENCE    
  acPMSS7RxMTP3MSUSN Unsigned32
  acPMSS7RxMTP3MSUInterval Unsigned32
  acPMSS7RxMTP3MSUVal Counter32
  acPMSS7RxMTP3MSUTotal Integer32

AcPMSS7TxMTP3UPUEntry  
SEQUENCE    
  acPMSS7TxMTP3UPUSN Unsigned32
  acPMSS7TxMTP3UPUInterval Unsigned32
  acPMSS7TxMTP3UPUVal Counter32
  acPMSS7TxMTP3UPUTotal Integer32

AcPMSS7RxMTP3UPUEntry  
SEQUENCE    
  acPMSS7RxMTP3UPUSN Unsigned32
  acPMSS7RxMTP3UPUInterval Unsigned32
  acPMSS7RxMTP3UPUVal Counter32
  acPMSS7RxMTP3UPUTotal Integer32

AcPMSS7MTP3MSUDiscardedEntry  
SEQUENCE    
  acPMSS7MTP3MSUDiscardedSN Unsigned32
  acPMSS7MTP3MSUDiscardedInterval Unsigned32
  acPMSS7MTP3MSUDiscardedVal Counter32
  acPMSS7MTP3MSUDiscardedTotal Integer32

AcPMSS7MTP3MSUDiscardedRtDataErrEntry  
SEQUENCE    
  acPMSS7MTP3MSUDiscardedRtDataErrSN Unsigned32
  acPMSS7MTP3MSUDiscardedRtDataErrInterval Unsigned32
  acPMSS7MTP3MSUDiscardedRtDataErrVal Counter32
  acPMSS7MTP3MSUDiscardedRtDataErrTotal Integer32

AcPMSS7RxMTP3TFCMsgEntry  
SEQUENCE    
  acPMSS7RxMTP3TFCMsgSN Unsigned32
  acPMSS7RxMTP3TFCMsgInterval Unsigned32
  acPMSS7RxMTP3TFCMsgVal Counter32
  acPMSS7RxMTP3TFCMsgTotal Integer32

AcPMSS7MTP2T1ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T1ExpiryLink Unsigned32
  acPMSS7MTP2T1ExpiryInterval Unsigned32
  acPMSS7MTP2T1ExpiryVal Counter32
  acPMSS7MTP2T1ExpiryTotal Integer32

AcPMSS7MTP2T2ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T2ExpiryLink Unsigned32
  acPMSS7MTP2T2ExpiryInterval Unsigned32
  acPMSS7MTP2T2ExpiryVal Counter32
  acPMSS7MTP2T2ExpiryTotal Integer32

AcPMSS7MTP2T3ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T3ExpiryLink Unsigned32
  acPMSS7MTP2T3ExpiryInterval Unsigned32
  acPMSS7MTP2T3ExpiryVal Counter32
  acPMSS7MTP2T3ExpiryTotal Integer32

AcPMSS7MTP2T4ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T4ExpiryLink Unsigned32
  acPMSS7MTP2T4ExpiryInterval Unsigned32
  acPMSS7MTP2T4ExpiryVal Counter32
  acPMSS7MTP2T4ExpiryTotal Integer32

AcPMSS7MTP2T5ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T5ExpiryLink Unsigned32
  acPMSS7MTP2T5ExpiryInterval Unsigned32
  acPMSS7MTP2T5ExpiryVal Counter32
  acPMSS7MTP2T5ExpiryTotal Integer32

AcPMSS7MTP2T6ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T6ExpiryLink Unsigned32
  acPMSS7MTP2T6ExpiryInterval Unsigned32
  acPMSS7MTP2T6ExpiryVal Counter32
  acPMSS7MTP2T6ExpiryTotal Integer32

AcPMSS7MTP2T7ExpiryEntry  
SEQUENCE    
  acPMSS7MTP2T7ExpiryLink Unsigned32
  acPMSS7MTP2T7ExpiryInterval Unsigned32
  acPMSS7MTP2T7ExpiryVal Counter32
  acPMSS7MTP2T7ExpiryTotal Integer32

Defined Values

acPMSS7 1.3.6.1.4.1.5003.10.13
The AC-PM-SS7 MIB offers performance monitoring For the SS7 related elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-SS7 MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
MODULE-IDENTITY    

acPMSS7Configuration 1.3.6.1.4.1.5003.10.13.1
OBJECT IDENTIFIER    

acPMSS7ConfigurationPeriodLength 1.3.6.1.4.1.5003.10.13.1.1
Length of monitoring intervals for entire MIB. Time is in minutes. Access: Online.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..894780  

acPMSS7ConfigurationResetTotalCounters 1.3.6.1.4.1.5003.10.13.1.2
Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Access: Online.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER resetCountersDone(1), resetTotalCounters(2)  

acPMSS7Data 1.3.6.1.4.1.5003.10.13.2
OBJECT IDENTIFIER    

acPMSS7DataTimeFromStartOfInterval 1.3.6.1.4.1.5003.10.13.2.1
The time in seconds since the start of the current interval. MIB specific.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2147483647  


acPMSS7TxMSUTable 1.3.6.1.4.1.5003.10.13.2.31.1
Number of transmitted MSU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxMSUEntry

acPMSS7TxMSUEntry 1.3.6.1.4.1.5003.10.13.2.31.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxMSUEntry  


acPMSS7TxMSUInterval 1.3.6.1.4.1.5003.10.13.2.31.1.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMSUVal 1.3.6.1.4.1.5003.10.13.2.31.1.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxMSUTotal 1.3.6.1.4.1.5003.10.13.2.31.1.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxMSUTable 1.3.6.1.4.1.5003.10.13.2.31.2
Number of received MSU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxMSUEntry

acPMSS7RxMSUEntry 1.3.6.1.4.1.5003.10.13.2.31.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxMSUEntry  


acPMSS7RxMSUInterval 1.3.6.1.4.1.5003.10.13.2.31.2.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMSUVal 1.3.6.1.4.1.5003.10.13.2.31.2.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxMSUTotal 1.3.6.1.4.1.5003.10.13.2.31.2.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxLSSUTable 1.3.6.1.4.1.5003.10.13.2.31.3
Number of transmitted LSSU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxLSSUEntry

acPMSS7TxLSSUEntry 1.3.6.1.4.1.5003.10.13.2.31.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxLSSUEntry  


acPMSS7TxLSSUInterval 1.3.6.1.4.1.5003.10.13.2.31.3.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxLSSUVal 1.3.6.1.4.1.5003.10.13.2.31.3.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxLSSUTotal 1.3.6.1.4.1.5003.10.13.2.31.3.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxLSSUTable 1.3.6.1.4.1.5003.10.13.2.31.4
Number of received LSSU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxLSSUEntry

acPMSS7RxLSSUEntry 1.3.6.1.4.1.5003.10.13.2.31.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxLSSUEntry  


acPMSS7RxLSSUInterval 1.3.6.1.4.1.5003.10.13.2.31.4.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxLSSUVal 1.3.6.1.4.1.5003.10.13.2.31.4.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxLSSUTotal 1.3.6.1.4.1.5003.10.13.2.31.4.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxFISUTable 1.3.6.1.4.1.5003.10.13.2.31.5
Number of transmitted FISU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxFISUEntry

acPMSS7TxFISUEntry 1.3.6.1.4.1.5003.10.13.2.31.5.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxFISUEntry  


acPMSS7TxFISUInterval 1.3.6.1.4.1.5003.10.13.2.31.5.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxFISUVal 1.3.6.1.4.1.5003.10.13.2.31.5.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxFISUTotal 1.3.6.1.4.1.5003.10.13.2.31.5.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxFISUTable 1.3.6.1.4.1.5003.10.13.2.31.6
Number of received FISU's per SS7 link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxFISUEntry

acPMSS7RxFISUEntry 1.3.6.1.4.1.5003.10.13.2.31.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxFISUEntry  


acPMSS7RxFISUInterval 1.3.6.1.4.1.5003.10.13.2.31.6.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxFISUVal 1.3.6.1.4.1.5003.10.13.2.31.6.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxFISUTotal 1.3.6.1.4.1.5003.10.13.2.31.6.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxSignalUnitsTable 1.3.6.1.4.1.5003.10.13.2.31.7
Number of transmitted Signaling units per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxSignalUnitsEntry

acPMSS7TxSignalUnitsEntry 1.3.6.1.4.1.5003.10.13.2.31.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxSignalUnitsEntry  


acPMSS7TxSignalUnitsInterval 1.3.6.1.4.1.5003.10.13.2.31.7.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxSignalUnitsVal 1.3.6.1.4.1.5003.10.13.2.31.7.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxSignalUnitsTotal 1.3.6.1.4.1.5003.10.13.2.31.7.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxSignalUnitsTable 1.3.6.1.4.1.5003.10.13.2.31.8
Number of received Signaling units per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxSignalUnitsEntry

acPMSS7RxSignalUnitsEntry 1.3.6.1.4.1.5003.10.13.2.31.8.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxSignalUnitsEntry  


acPMSS7RxSignalUnitsInterval 1.3.6.1.4.1.5003.10.13.2.31.8.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxSignalUnitsVal 1.3.6.1.4.1.5003.10.13.2.31.8.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxSignalUnitsTotal 1.3.6.1.4.1.5003.10.13.2.31.8.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxOctetsTable 1.3.6.1.4.1.5003.10.13.2.31.9
Number of transmitted Octets per SS7 link - Q.752 3.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxOctetsEntry

acPMSS7TxOctetsEntry 1.3.6.1.4.1.5003.10.13.2.31.9.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxOctetsEntry  


acPMSS7TxOctetsInterval 1.3.6.1.4.1.5003.10.13.2.31.9.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxOctetsVal 1.3.6.1.4.1.5003.10.13.2.31.9.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxOctetsTotal 1.3.6.1.4.1.5003.10.13.2.31.9.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxOctetsTable 1.3.6.1.4.1.5003.10.13.2.31.10
Number of received Octets per SS7 link - Q.752 3.4
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxOctetsEntry

acPMSS7RxOctetsEntry 1.3.6.1.4.1.5003.10.13.2.31.10.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxOctetsEntry  


acPMSS7RxOctetsInterval 1.3.6.1.4.1.5003.10.13.2.31.10.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxOctetsVal 1.3.6.1.4.1.5003.10.13.2.31.10.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxOctetsTotal 1.3.6.1.4.1.5003.10.13.2.31.10.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2NoAckRxTable 1.3.6.1.4.1.5003.10.13.2.31.11
Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2NoAckRxEntry

acPMSS7MTP2NoAckRxEntry 1.3.6.1.4.1.5003.10.13.2.31.11.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2NoAckRxEntry  


acPMSS7MTP2NoAckRxInterval 1.3.6.1.4.1.5003.10.13.2.31.11.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2NoAckRxVal 1.3.6.1.4.1.5003.10.13.2.31.11.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2NoAckRxTotal 1.3.6.1.4.1.5003.10.13.2.31.11.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7DiscMSUTable 1.3.6.1.4.1.5003.10.13.2.31.12
MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7DiscMSUEntry

acPMSS7DiscMSUEntry 1.3.6.1.4.1.5003.10.13.2.31.12.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7DiscMSUEntry  


acPMSS7DiscMSUInterval 1.3.6.1.4.1.5003.10.13.2.31.12.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7DiscMSUVal 1.3.6.1.4.1.5003.10.13.2.31.12.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7DiscMSUTotal 1.3.6.1.4.1.5003.10.13.2.31.12.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7InServiceTable 1.3.6.1.4.1.5003.10.13.2.31.13
Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7InServiceEntry

acPMSS7InServiceEntry 1.3.6.1.4.1.5003.10.13.2.31.13.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7InServiceEntry  


acPMSS7InServiceInterval 1.3.6.1.4.1.5003.10.13.2.31.13.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7InServiceVal 1.3.6.1.4.1.5003.10.13.2.31.13.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

acPMSS7InServiceTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.13.2.31.13.1.4
Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'In Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7InServiceTimeBetweenThresholds 1.3.6.1.4.1.5003.10.13.2.31.13.1.5
Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'In Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7OutOfServiceTable 1.3.6.1.4.1.5003.10.13.2.31.14
Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7OutOfServiceEntry

acPMSS7OutOfServiceEntry 1.3.6.1.4.1.5003.10.13.2.31.14.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7OutOfServiceEntry  


acPMSS7OutOfServiceInterval 1.3.6.1.4.1.5003.10.13.2.31.14.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7OutOfServiceVal 1.3.6.1.4.1.5003.10.13.2.31.14.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

acPMSS7OutOfServiceTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.13.2.31.14.1.4
Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7OutOfServiceTimeBetweenThresholds 1.3.6.1.4.1.5003.10.13.2.31.14.1.5
Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7LinkSets 1.3.6.1.4.1.5003.10.13.2.41
OBJECT IDENTIFIER    

acPMSS7SN0LSOutOfServiceTable 1.3.6.1.4.1.5003.10.13.2.41.1
Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7SN0LSOutOfServiceEntry

acPMSS7SN0LSOutOfServiceEntry 1.3.6.1.4.1.5003.10.13.2.41.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7SN0LSOutOfServiceEntry  

acPMSS7SN0LSOutOfServiceLinkSet 1.3.6.1.4.1.5003.10.13.2.41.1.1.1
Link Set number. 0 is the first link.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..31  

acPMSS7SN0LSOutOfServiceInterval 1.3.6.1.4.1.5003.10.13.2.41.1.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7SN0LSOutOfServiceVal 1.3.6.1.4.1.5003.10.13.2.41.1.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.13.2.41.1.1.4
Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7SN0LSOutOfServiceTimeBetweenThresholds 1.3.6.1.4.1.5003.10.13.2.41.1.1.5
Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7SN1LSOutOfServiceTable 1.3.6.1.4.1.5003.10.13.2.41.2
Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7SN1LSOutOfServiceEntry

acPMSS7SN1LSOutOfServiceEntry 1.3.6.1.4.1.5003.10.13.2.41.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7SN1LSOutOfServiceEntry  

acPMSS7SN1LSOutOfServiceLinkSet 1.3.6.1.4.1.5003.10.13.2.41.2.1.1
Link Set number. 0 is the first link.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..31  

acPMSS7SN1LSOutOfServiceInterval 1.3.6.1.4.1.5003.10.13.2.41.2.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7SN1LSOutOfServiceVal 1.3.6.1.4.1.5003.10.13.2.41.2.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold 1.3.6.1.4.1.5003.10.13.2.41.2.1.4
Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7SN1LSOutOfServiceTimeBetweenThresholds 1.3.6.1.4.1.5003.10.13.2.41.2.1.5
Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..100  

acPMSS7SignalingNodes 1.3.6.1.4.1.5003.10.13.2.51
OBJECT IDENTIFIER    

acPMSS7TxMTP3OctetsTable 1.3.6.1.4.1.5003.10.13.2.51.1
Number of transmitted MTP3 octets per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxMTP3OctetsEntry

acPMSS7TxMTP3OctetsEntry 1.3.6.1.4.1.5003.10.13.2.51.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxMTP3OctetsEntry  

acPMSS7TxMTP3OctetsSN 1.3.6.1.4.1.5003.10.13.2.51.1.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3OctetsInterval 1.3.6.1.4.1.5003.10.13.2.51.1.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3OctetsVal 1.3.6.1.4.1.5003.10.13.2.51.1.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxMTP3OctetsTotal 1.3.6.1.4.1.5003.10.13.2.51.1.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxMTP3OctetsTable 1.3.6.1.4.1.5003.10.13.2.51.2
Number of received MTP3 octets per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxMTP3OctetsEntry

acPMSS7RxMTP3OctetsEntry 1.3.6.1.4.1.5003.10.13.2.51.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxMTP3OctetsEntry  

acPMSS7RxMTP3OctetsSN 1.3.6.1.4.1.5003.10.13.2.51.2.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3OctetsInterval 1.3.6.1.4.1.5003.10.13.2.51.2.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3OctetsVal 1.3.6.1.4.1.5003.10.13.2.51.2.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxMTP3OctetsTotal 1.3.6.1.4.1.5003.10.13.2.51.2.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxMTP3MSUTable 1.3.6.1.4.1.5003.10.13.2.51.3
Number of transmitted MTP3 MSU's per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxMTP3MSUEntry

acPMSS7TxMTP3MSUEntry 1.3.6.1.4.1.5003.10.13.2.51.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxMTP3MSUEntry  

acPMSS7TxMTP3MSUSN 1.3.6.1.4.1.5003.10.13.2.51.3.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3MSUInterval 1.3.6.1.4.1.5003.10.13.2.51.3.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3MSUVal 1.3.6.1.4.1.5003.10.13.2.51.3.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxMTP3MSUTotal 1.3.6.1.4.1.5003.10.13.2.51.3.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxMTP3MSUTable 1.3.6.1.4.1.5003.10.13.2.51.4
Number of received MTP3 MSU's per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxMTP3MSUEntry

acPMSS7RxMTP3MSUEntry 1.3.6.1.4.1.5003.10.13.2.51.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxMTP3MSUEntry  

acPMSS7RxMTP3MSUSN 1.3.6.1.4.1.5003.10.13.2.51.4.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3MSUInterval 1.3.6.1.4.1.5003.10.13.2.51.4.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3MSUVal 1.3.6.1.4.1.5003.10.13.2.51.4.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxMTP3MSUTotal 1.3.6.1.4.1.5003.10.13.2.51.4.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7TxMTP3UPUTable 1.3.6.1.4.1.5003.10.13.2.51.5
Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7TxMTP3UPUEntry

acPMSS7TxMTP3UPUEntry 1.3.6.1.4.1.5003.10.13.2.51.5.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7TxMTP3UPUEntry  

acPMSS7TxMTP3UPUSN 1.3.6.1.4.1.5003.10.13.2.51.5.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3UPUInterval 1.3.6.1.4.1.5003.10.13.2.51.5.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7TxMTP3UPUVal 1.3.6.1.4.1.5003.10.13.2.51.5.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7TxMTP3UPUTotal 1.3.6.1.4.1.5003.10.13.2.51.5.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxMTP3UPUTable 1.3.6.1.4.1.5003.10.13.2.51.6
Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxMTP3UPUEntry

acPMSS7RxMTP3UPUEntry 1.3.6.1.4.1.5003.10.13.2.51.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxMTP3UPUEntry  

acPMSS7RxMTP3UPUSN 1.3.6.1.4.1.5003.10.13.2.51.6.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3UPUInterval 1.3.6.1.4.1.5003.10.13.2.51.6.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3UPUVal 1.3.6.1.4.1.5003.10.13.2.51.6.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxMTP3UPUTotal 1.3.6.1.4.1.5003.10.13.2.51.6.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP3MSUDiscardedTable 1.3.6.1.4.1.5003.10.13.2.51.7
Number of discarded MTP3 MSU's per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP3MSUDiscardedEntry

acPMSS7MTP3MSUDiscardedEntry 1.3.6.1.4.1.5003.10.13.2.51.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP3MSUDiscardedEntry  

acPMSS7MTP3MSUDiscardedSN 1.3.6.1.4.1.5003.10.13.2.51.7.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP3MSUDiscardedInterval 1.3.6.1.4.1.5003.10.13.2.51.7.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP3MSUDiscardedVal 1.3.6.1.4.1.5003.10.13.2.51.7.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP3MSUDiscardedTotal 1.3.6.1.4.1.5003.10.13.2.51.7.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP3MSUDiscardedRtDataErrTable 1.3.6.1.4.1.5003.10.13.2.51.8
Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP3MSUDiscardedRtDataErrEntry

acPMSS7MTP3MSUDiscardedRtDataErrEntry 1.3.6.1.4.1.5003.10.13.2.51.8.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP3MSUDiscardedRtDataErrEntry  

acPMSS7MTP3MSUDiscardedRtDataErrSN 1.3.6.1.4.1.5003.10.13.2.51.8.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP3MSUDiscardedRtDataErrInterval 1.3.6.1.4.1.5003.10.13.2.51.8.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP3MSUDiscardedRtDataErrVal 1.3.6.1.4.1.5003.10.13.2.51.8.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP3MSUDiscardedRtDataErrTotal 1.3.6.1.4.1.5003.10.13.2.51.8.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7RxMTP3TFCMsgTable 1.3.6.1.4.1.5003.10.13.2.51.9
Number of MTP3 TFC messages received per SS7 MTP3 node
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7RxMTP3TFCMsgEntry

acPMSS7RxMTP3TFCMsgEntry 1.3.6.1.4.1.5003.10.13.2.51.9.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7RxMTP3TFCMsgEntry  

acPMSS7RxMTP3TFCMsgSN 1.3.6.1.4.1.5003.10.13.2.51.9.1.1
SN number. 0 is the first SN.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3TFCMsgInterval 1.3.6.1.4.1.5003.10.13.2.51.9.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7RxMTP3TFCMsgVal 1.3.6.1.4.1.5003.10.13.2.51.9.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7RxMTP3TFCMsgTotal 1.3.6.1.4.1.5003.10.13.2.51.9.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MPT2Timers 1.3.6.1.4.1.5003.10.13.2.61
OBJECT IDENTIFIER    

acPMSS7MTP2T1ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.1
Number of MTP2 T1 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T1ExpiryEntry

acPMSS7MTP2T1ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T1ExpiryEntry  


acPMSS7MTP2T1ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.1.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T1ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.1.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T1ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.1.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T2ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.2
Number of MTP2 T2 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T2ExpiryEntry

acPMSS7MTP2T2ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T2ExpiryEntry  


acPMSS7MTP2T2ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.2.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T2ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.2.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T2ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.2.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T3ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.3
Number of MTP2 T3 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T3ExpiryEntry

acPMSS7MTP2T3ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.3.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T3ExpiryEntry  


acPMSS7MTP2T3ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.3.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T3ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.3.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T3ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.3.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T4ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.4
Number of MTP2 T4 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T4ExpiryEntry

acPMSS7MTP2T4ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.4.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T4ExpiryEntry  


acPMSS7MTP2T4ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.4.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T4ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.4.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T4ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.4.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T5ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.5
Number of MTP2 T5 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T5ExpiryEntry

acPMSS7MTP2T5ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.5.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T5ExpiryEntry  


acPMSS7MTP2T5ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.5.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T5ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.5.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T5ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.5.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T6ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.6
Number of MTP2 T6 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T6ExpiryEntry

acPMSS7MTP2T6ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.6.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T6ExpiryEntry  


acPMSS7MTP2T6ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.6.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T6ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.6.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T6ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.6.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647  

acPMSS7MTP2T7ExpiryTable 1.3.6.1.4.1.5003.10.13.2.61.7
Number of MTP2 T7 expiry per SS7 link
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AcPMSS7MTP2T7ExpiryEntry

acPMSS7MTP2T7ExpiryEntry 1.3.6.1.4.1.5003.10.13.2.61.7.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  AcPMSS7MTP2T7ExpiryEntry  


acPMSS7MTP2T7ExpiryInterval 1.3.6.1.4.1.5003.10.13.2.61.7.1.2
Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 0..2  

acPMSS7MTP2T7ExpiryVal 1.3.6.1.4.1.5003.10.13.2.61.7.1.3
Value of gauge or counter.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

acPMSS7MTP2T7ExpiryTotal 1.3.6.1.4.1.5003.10.13.2.61.7.1.4
Total since last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -1..2147483647