A3COM-HUAWEI-LswMix-MIB

File: A3COM-HUAWEI-LswMix-MIB.mib (4613 bytes)

Imported modules

SNMPv2-SMI A3COM-HUAWEI-DEVICE-MIB A3COM-HUAWEI-OID-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
hwLswFrameIndex hwLswSlotIndex lswCommon

Defined Types

HwLswXSlotEntry  
SEQUENCE    
  hwLswMainCardBoardStatus INTEGER
  hwLswCrossBarStatus INTEGER

Defined Values

hwLswMix 1.3.6.1.4.1.43.45.1.2.23.1.17
Tok_String
MODULE-IDENTITY    

hwLswLastSwitchDate 1.3.6.1.4.1.43.45.1.2.23.1.17.1
This object indicates the date of the most recent change to the mpu(Main Processing Unit).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

hwLswLastSwitchTime 1.3.6.1.4.1.43.45.1.2.23.1.17.2
This object indicates the time of the most recent change to the mpu.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

hwLswMpuSwitchsNum 1.3.6.1.4.1.43.45.1.2.23.1.17.3
This object indicates the total times of the mpu switched since the system start up.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

hwLswMpuSwitch 1.3.6.1.4.1.43.45.1.2.23.1.17.4
Setting this object will immediately switch the standby mpu to master mpu. Read is not supported.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER switch(1)  

hwLswXSlotTable 1.3.6.1.4.1.43.45.1.2.23.1.17.5
The source main table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HwLswXSlotEntry

hwLswXSlotEntry 1.3.6.1.4.1.43.45.1.2.23.1.17.5.1
An entry in the source main table.
Status: current Access: not-accessible
OBJECT-TYPE    
  HwLswXSlotEntry  

hwLswMainCardBoardStatus 1.3.6.1.4.1.43.45.1.2.23.1.17.5.1.1
The value describes whether the board is master, standby or process. master and standby are the possible states for the mpu, while process indicates the state of lpu(Line Processing Unit)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), standby(2), process(3)  

hwLswCrossBarStatus 1.3.6.1.4.1.43.45.1.2.23.1.17.5.1.2
The value describes whether the crossbar is master or standby. It is master when it's in the master mpu board, standby when in the standby mpu. But both crossbars in mpus are master when the device in load-balance mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER master(1), standby(2)  

hwsMixTrapMib 1.3.6.1.4.1.43.45.1.2.23.1.17.10
OBJECT IDENTIFIER    

hwSlaveSwitchOver 1.3.6.1.4.1.43.45.1.2.23.1.17.10.1
An hwSlaveSwitchOver trap signifies that the action of standby mpu switching to master has completed.
Status: current Access: read-only
NOTIFICATION-TYPE