WebGraph-8xThermometer-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 22.06.2010 Output with decimal point -- ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 12.01.2009 Webio -- Trap number ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 19.01.2007 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 23.12.2005 #5760x, WebGraph 8x Thermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioAn8Graph OBJECT IDENTIFIER ::= { wtWebio 6 } -- wtWebioAn8Graph Tree wtWebioAn8GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn8Graph 1 } wtWebioAn8GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn8Graph 2 } wtWebioAn8GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn8Graph 3 } wtWebioAn8GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn8Graph 4 } -- wtWebioAn8GraphConfig Tree wtWebioAn8GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 1 } wtWebioAn8GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 2 } wtWebioAn8GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn8GraphConfig 3 } -- wtWebioAn8GraphDevice Tree wtWebioAn8GraphText OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 1 } wtWebioAn8GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 2 } wtWebioAn8GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 3 } wtWebioAn8GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 4 } wtWebioAn8GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 5 } wtWebioAn8GraphGraphics OBJECT IDENTIFIER ::= { wtWebioAn8GraphDevice 6 } -- wtWebioAn8GraphTimeDate Tree wtWebioAn8GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 1 } wtWebioAn8GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 2 } wtWebioAn8GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn8GraphTimeDate 3 } -- wtWebioAn8GraphBasic Tree wtWebioAn8GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 1 } wtWebioAn8GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 2 } wtWebioAn8GraphMail OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 3 } wtWebioAn8GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 4 } wtWebioAn8GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 5 } wtWebioAn8GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 6 } wtWebioAn8GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn8GraphBasic 7 } -- wtWebioAn8GraphGraphics Tree wtWebioAn8GraphGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 1 } wtWebioAn8GraphGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 2 } wtWebioAn8GraphGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn8GraphGraphics 3 } -- wtWebioAn8GraphTemp Group ------------------------ wtWebioAn8GraphSensors OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of temperature sensors" ::= { wtWebioAn8GraphTemp 1 } -- Interface Table wtWebioAn8GraphSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebioAn8GraphTemp 2 } wtWebioAn8GraphSensorEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperature sensor numbers." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphSensorTable 1 } WtWebioAn8GraphSensorEntry ::= SEQUENCE { wtWebioAn8GraphSensorNo INTEGER } wtWebioAn8GraphSensorNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor number." ::= { wtWebioAn8GraphSensorEntry 1 } -- wtWebioAn8GraphTempValue Table wtWebioAn8GraphTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn8GraphTemp 3 } wtWebioAn8GraphTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphTempValueTable 1 } WtWebioAn8GraphTempValueEntry ::= SEQUENCE{ wtWebioAn8GraphTempValue OCTET STRING } wtWebioAn8GraphTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length." ::= { wtWebioAn8GraphTempValueEntry 1 } -- wtWebioAn8GraphBinaryTempValue Table wtWebioAn8GraphBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary temperature values corresponding to the channel numbers." ::= { wtWebioAn8GraphTemp 4 } wtWebioAn8GraphBinaryTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary temperature values of the sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphBinaryTempValueTable 1 } WtWebioAn8GraphBinaryTempValueEntry ::= SEQUENCE{ wtWebioAn8GraphBinaryTempValue INTEGER } wtWebioAn8GraphBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x4FFF6 indicates an invalid measured value." ::= { wtWebioAn8GraphBinaryTempValueEntry 1 } -- wtWebioAn8GraphTempValuePkt Table wtWebioAn8GraphTempValuePktTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn8GraphTemp 8 } wtWebioAn8GraphTempValuePktEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphTempValuePktTable 1 } WtWebioAn8GraphTempValuePktEntry ::= SEQUENCE{ wtWebioAn8GraphTempValuePkt OCTET STRING } wtWebioAn8GraphTempValuePkt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length, decimal point." ::= { wtWebioAn8GraphTempValuePktEntry 1 } -- wtWebioAn8GraphSessCntrl Group -------------------------------- wtWebioAn8GraphSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioAn8GraphSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioAn8GraphSessCntrl 1 } wtWebioAn8GraphSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphSessCntrl-NoSession(0), wtWebioAn8GraphSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioAn8GraphSessCntrl 2 } wtWebioAn8GraphSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioAn8GraphSessCntrl 3 } wtWebioAn8GraphSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioAn8GraphSessCntrl 4 } wtWebioAn8GraphSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioAn8GraphSessCntrl 5 } -- wtWebioAn8GraphText Group ------------------------ wtWebioAn8GraphDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioAn8GraphText 1 } wtWebioAn8GraphDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioAn8GraphText 2 } wtWebioAn8GraphDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioAn8GraphText 3 } wtWebioAn8GraphDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioAn8GraphText 4 } -- wtWebioAn8GraphTimeZone Group ---------------------------- wtWebioAn8GraphTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioAn8GraphTimeZone 1 } wtWebioAn8GraphTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioAn8GraphTimeZone 2 } wtWebioAn8GraphTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioAn8GraphTimeZone 3 } wtWebioAn8GraphStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioAn8GraphTimeZone 4 } wtWebioAn8GraphStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioAn8GraphTimeZone 5 } wtWebioAn8GraphStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioAn8GraphTimeZone 6 } wtWebioAn8GraphStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStartMonth-January(1), wtWebioAn8GraphStartMonth-February(2), wtWebioAn8GraphStartMonth-March(3), wtWebioAn8GraphStartMonth-April(4), wtWebioAn8GraphStartMonth-May(5), wtWebioAn8GraphStartMonth-June(6), wtWebioAn8GraphStartMonth-July(7), wtWebioAn8GraphStartMonth-August(8), wtWebioAn8GraphStartMonth-September(9), wtWebioAn8GraphStartMonth-October(10), wtWebioAn8GraphStartMonth-November(11), wtWebioAn8GraphStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioAn8GraphTimeZone 7 } wtWebioAn8GraphStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStartMode-first(1), wtWebioAn8GraphStartMode-second(2), wtWebioAn8GraphStartMode-third(3), wtWebioAn8GraphStartMode-fourth(4), wtWebioAn8GraphStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioAn8GraphTimeZone 8 } wtWebioAn8GraphStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStartWday-Sunday(1), wtWebioAn8GraphStartWday-Monday(2), wtWebioAn8GraphStartWday-Tuesday(3), wtWebioAn8GraphStartWday-Thursday(4), wtWebioAn8GraphStartWday-Wednesday(5), wtWebioAn8GraphStartWday-Friday(6), wtWebioAn8GraphStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioAn8GraphTimeZone 9 } wtWebioAn8GraphStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn8GraphTimeZone 10 } wtWebioAn8GraphStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn8GraphTimeZone 11 } wtWebioAn8GraphStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStopMonth-January(1), wtWebioAn8GraphStopMonth-February(2), wtWebioAn8GraphStopMonth-March(3), wtWebioAn8GraphStopMonth-April(4), wtWebioAn8GraphStopMonth-May(5), wtWebioAn8GraphStopMonth-June(6), wtWebioAn8GraphStopMonth-July(7), wtWebioAn8GraphStopMonth-August(8), wtWebioAn8GraphStopMonth-September(9), wtWebioAn8GraphStopMonth-October(10), wtWebioAn8GraphStopMonth-November(11), wtWebioAn8GraphStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioAn8GraphTimeZone 12 } wtWebioAn8GraphStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStopMode-first(1), wtWebioAn8GraphStopMode-second(2), wtWebioAn8GraphStopMode-third(3), wtWebioAn8GraphStopMode-fourth(4), wtWebioAn8GraphStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioAn8GraphTimeZone 13 } wtWebioAn8GraphStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphStopWday-Sunday(1), wtWebioAn8GraphStopWday-Monday(2), wtWebioAn8GraphStopWday-Tuesday(3), wtWebioAn8GraphStopWday-Thursday(4), wtWebioAn8GraphStopWday-Wednesday(5), wtWebioAn8GraphStopWday-Friday(6), wtWebioAn8GraphStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioAn8GraphTimeZone 14 } wtWebioAn8GraphStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn8GraphTimeZone 15 } wtWebioAn8GraphStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn8GraphTimeZone 16 } -- wtWebioAn8GraphTimeServer Group ---------------------------- wtWebioAn8GraphTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioAn8GraphTimeServer 1 } wtWebioAn8GraphTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioAn8GraphTimeServer 2 } wtWebioAn8GraphTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioAn8GraphTimeServer 3 } wtWebioAn8GraphTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioAn8GraphTimeServer 4 } -- wtWebioAn8GraphDeviceClock Group ---------------------------- wtWebioAn8GraphClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioAn8GraphDeviceClock 1 } wtWebioAn8GraphClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioAn8GraphDeviceClock 2 } wtWebioAn8GraphClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioAn8GraphDeviceClock 3 } wtWebioAn8GraphClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphClockMonth-January(1), wtWebioAn8GraphClockMonth-February(2), wtWebioAn8GraphClockMonth-March(3), wtWebioAn8GraphClockMonth-April(4), wtWebioAn8GraphClockMonth-May(5), wtWebioAn8GraphClockMonth-June(6), wtWebioAn8GraphClockMonth-July(7), wtWebioAn8GraphClockMonth-August(8), wtWebioAn8GraphClockMonth-September(9), wtWebioAn8GraphClockMonth-October(10), wtWebioAn8GraphClockMonth-November(11), wtWebioAn8GraphClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioAn8GraphDeviceClock 4 } wtWebioAn8GraphClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioAn8GraphDeviceClock 5 } -- wtWebioAn8GraphNetwork Group ------------------------ wtWebioAn8GraphIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioAn8GraphNetwork 1 } wtWebioAn8GraphSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioAn8GraphNetwork 2 } wtWebioAn8GraphGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioAn8GraphNetwork 3 } wtWebioAn8GraphDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioAn8GraphNetwork 4 } wtWebioAn8GraphDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioAn8GraphNetwork 5 } wtWebioAn8GraphAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disable " ::= { wtWebioAn8GraphNetwork 6 } -- wtWebioAn8GraphHTTP Group -------------------------------- wtWebioAn8GraphStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebioAn8GraphHTTP 1 } wtWebioAn8GraphGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioAn8GraphHTTP 2 } wtWebioAn8GraphHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioAn8GraphHTTP 3 } -- wtWebioAn8GraphMail Group -------------------------------- wtWebioAn8GraphMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioAn8GraphMail 1 } wtWebioAn8GraphMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioAn8GraphMail 2 } wtWebioAn8GraphMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioAn8GraphMail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioAn8GraphMail 4 } wtWebioAn8GraphMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioAn8GraphMail 5 } wtWebioAn8GraphMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioAn8GraphMail 6 } wtWebioAn8GraphMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioAn8GraphMail 7 } wtWebioAn8GraphMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioAn8GraphMail 8 } -- wtWebioAn8GraphSNMP Group -------------------------------- wtWebioAn8GraphSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioAn8GraphSNMP 1 } wtWebioAn8GraphSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioAn8GraphSNMP 2 } wtWebioAn8GraphSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioAn8GraphSNMP 3 } wtWebioAn8GraphSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebioAn8GraphSNMP 4 } wtWebioAn8GraphSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioAn8GraphSNMP 5 } wtWebioAn8GraphSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebioAn8GraphSNMP 6 } -- wtWebioAn8GraphUDP Group -------------------------------- wtWebioAn8GraphUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioAn8GraphUDP 1 } wtWebioAn8GraphUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioAn8GraphUDP 2 } -- wtWebioAn8GraphSyslog Group -------------------------------- wtWebioAn8GraphSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioAn8GraphSyslog 1 } wtWebioAn8GraphSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioAn8GraphSyslog 2 } wtWebioAn8GraphSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioAn8GraphSyslog 3 } wtWebioAn8GraphSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioAn8GraphSyslog 4 } -- wtWebioAn8GraphFTP Group -------------------------------- wtWebioAn8GraphFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioAn8GraphFTP 1 } wtWebioAn8GraphFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioAn8GraphFTP 2 } wtWebioAn8GraphFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioAn8GraphFTP 3 } wtWebioAn8GraphFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioAn8GraphFTP 4 } wtWebioAn8GraphFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioAn8GraphFTP 5 } wtWebioAn8GraphFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioAn8GraphFTP 6 } wtWebioAn8GraphFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioAn8GraphFTP 7 } -- wtWebioAn8GraphDatalogger Group -------------------------------- wtWebioAn8GraphLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphDatalogger-1Min(1), wtWebioAn8GraphDatalogger-5Min(2), wtWebioAn8GraphDatalogger-15Min(3), wtWebioAn8GraphDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebioAn8GraphDatalogger 1 } wtWebioAn8GraphLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn8GraphDatalogger 2 } wtWebioAn8GraphDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn8GraphDatalogger 3 } -- Graph Sensor Color Table wtWebioAn8GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn8GraphDatalogger 4 } wtWebioAn8GraphSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphSensorColorTable 1 } WtWebioAn8GraphSensorColorEntry ::= SEQUENCE { wtWebioAn8GraphSensorColor OCTET STRING } wtWebioAn8GraphSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn8GraphSensorColorEntry 1 } wtWebioAn8GraphAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebioAn8GraphDatalogger 5 } wtWebioAn8GraphVerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphDatalogger 6 } wtWebioAn8GraphVerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphDatalogger 7 } wtWebioAn8GraphHorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebioAn8GraphZoom-25min(1), wtWebioAn8GraphZoom-75min(2), wtWebioAn8GraphZoom-5hrs(3), wtWebioAn8GraphZoom-30hrs(4), wtWebioAn8GraphZoom-5days(5), wtWebioAn8GraphZoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebioAn8GraphDatalogger 8 } -- wtWebioAn8GraphAlarm Group ---------------------------- wtWebioAn8GraphAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioAn8GraphAlarm 1 } -- Alarm Interface Table wtWebioAn8GraphAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioAn8GraphAlarm 2 } wtWebioAn8GraphAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioAn8GraphAlarmNo } ::= { wtWebioAn8GraphAlarmIfTable 1 } WtWebioAn8GraphAlarmIfEntry ::= SEQUENCE { wtWebioAn8GraphAlarmNo INTEGER } wtWebioAn8GraphAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebioAn8GraphAlarmIfEntry 1 } -- Alarm Table wtWebioAn8GraphAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioAn8GraphAlarm 3 } wtWebioAn8GraphAlarmEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioAn8GraphAlarmNo } ::= { wtWebioAn8GraphAlarmTable 1 } WtWebioAn8GraphAlarmEntry ::= SEQUENCE { wtWebioAn8GraphAlarmTrigger OCTET STRING, wtWebioAn8GraphAlarmMin OCTET STRING, wtWebioAn8GraphAlarmMax OCTET STRING, wtWebioAn8GraphAlarmHysteresis OCTET STRING, wtWebioAn8GraphAlarmDelay OCTET STRING, wtWebioAn8GraphAlarmInterval OCTET STRING, wtWebioAn8GraphAlarmEnable OCTET STRING, wtWebioAn8GraphAlarmEMailAddr OCTET STRING, wtWebioAn8GraphAlarmMailSubject OCTET STRING, wtWebioAn8GraphAlarmMailText OCTET STRING, wtWebioAn8GraphAlarmManagerIP OCTET STRING, wtWebioAn8GraphAlarmTrapText OCTET STRING, wtWebioAn8GraphAlarmMailOptions OCTET STRING, wtWebioAn8GraphAlarmTcpIpAddr OCTET STRING, wtWebioAn8GraphAlarmTcpPort INTEGER, wtWebioAn8GraphAlarmTcpText OCTET STRING, wtWebioAn8GraphAlarmClearMailSubject OCTET STRING, wtWebioAn8GraphAlarmClearMailText OCTET STRING, wtWebioAn8GraphAlarmClearTrapText OCTET STRING, wtWebioAn8GraphAlarmClearTcpText OCTET STRING, wtWebioAn8GraphAlarmSyslogIpAddr OCTET STRING, wtWebioAn8GraphAlarmSyslogPort INTEGER, wtWebioAn8GraphAlarmSyslogText OCTET STRING, wtWebioAn8GraphAlarmFtpDataPort OCTET STRING, wtWebioAn8GraphAlarmFtpFileName OCTET STRING, wtWebioAn8GraphAlarmFtpText OCTET STRING, wtWebioAn8GraphAlarmFtpClearText OCTET STRING, wtWebioAn8GraphAlarmFtpOption OCTET STRING, wtWebioAn8GraphAlarmTimerCron OCTET STRING } wtWebioAn8GraphAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn8GraphAlarmEntry 1 } wtWebioAn8GraphAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphAlarmEntry 2 } wtWebioAn8GraphAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphAlarmEntry 3 } wtWebioAn8GraphAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphAlarmEntry 4 } wtWebioAn8GraphAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebioAn8GraphAlarmEntry 5 } wtWebioAn8GraphAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioAn8GraphAlarmEntry 6 } wtWebioAn8GraphAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebioAn8GraphAlarmEntry 7 } wtWebioAn8GraphAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioAn8GraphAlarmEntry 8 } wtWebioAn8GraphAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioAn8GraphAlarmEntry 9 } wtWebioAn8GraphAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn8GraphAlarmEntry 10 } wtWebioAn8GraphAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebioAn8GraphAlarmEntry 11 } wtWebioAn8GraphAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn8GraphAlarmEntry 12 } wtWebioAn8GraphAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebioAn8GraphAlarmEntry 13 } wtWebioAn8GraphAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebioAn8GraphAlarmEntry 14 } wtWebioAn8GraphAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebioAn8GraphAlarmEntry 15 } wtWebioAn8GraphAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn8GraphAlarmEntry 16 } wtWebioAn8GraphAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebioAn8GraphAlarmEntry 17 } wtWebioAn8GraphAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn8GraphAlarmEntry 18 } wtWebioAn8GraphAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn8GraphAlarmEntry 19 } wtWebioAn8GraphAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn8GraphAlarmEntry 20 } wtWebioAn8GraphAlarmSyslogIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn8GraphAlarmEntry 21 } wtWebioAn8GraphAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn8GraphAlarmEntry 22 } wtWebioAn8GraphAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn8GraphAlarmEntry 23 } wtWebioAn8GraphAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn8GraphAlarmEntry 24 } wtWebioAn8GraphAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioAn8GraphAlarmEntry 25 } wtWebioAn8GraphAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioAn8GraphAlarmEntry 26 } wtWebioAn8GraphAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioAn8GraphAlarmEntry 27 } wtWebioAn8GraphAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebioAn8GraphAlarmEntry 28 } wtWebioAn8GraphAlarmFtpOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioAn8GraphAlarmEntry 29 } wtWebioAn8GraphAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioAn8GraphAlarmEntry 30 } -- wtWebioAn8GraphGraphicsBase Group ---------------------------- wtWebioAn8GraphGraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebioAn8GraphGraphicsBase 1 } wtWebioAn8GraphGraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebioAn8GraphGraphicsBase 2 } wtWebioAn8GraphGraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebioAn8GraphGraphicsBase 3 } wtWebioAn8GraphGraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebioAn8GraphGraphicsBase 4 } wtWebioAn8GraphGraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebioAn8GraphGraphicsBase 5 } wtWebioAn8GraphGraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebioAn8GraphGraphicsBase 6 } -- wtWebioAn8GraphGraphicsSelect Group ---------------------------- wtWebioAn8GraphGraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn8GraphGraphicsSelect 1 } wtWebioAn8GraphGraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn8GraphGraphicsSelect 2 } -- Graph Sensor Color Table wtWebioAn8GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn8GraphGraphicsSelect 3 } wtWebioAn8GraphSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphSensorColorTable 1 } WtWebioAn8GraphSensorColorEntry ::= SEQUENCE { wtWebioAn8GraphGraphicsSensorColor OCTET STRING, wtWebioAn8GraphGraphicsSelectScale OCTET STRING } wtWebioAn8GraphGraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn8GraphSensorColorEntry 1 } wtWebioAn8GraphGraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unused" ::= { wtWebioAn8GraphSensorColorEntry 2 } -- wtWebioAn8GraphGraphicsScale Group ---------------------------- wtWebioAn8GraphGraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unused" ::= { wtWebioAn8GraphGraphicsScale 1 } wtWebioAn8GraphGraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unused" ::= { wtWebioAn8GraphGraphicsScale 2 } wtWebioAn8GraphGraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebioAn8GraphGraphicsScale 3 } wtWebioAn8GraphGraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebioAn8GraphGraphicsScale 4 } wtWebioAn8GraphGraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Minimum." ::= { wtWebioAn8GraphGraphicsScale 5 } wtWebioAn8GraphGraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Minimum." ::= { wtWebioAn8GraphGraphicsScale 6 } wtWebioAn8GraphGraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebioAn8GraphGraphicsScale 7 } wtWebioAn8GraphGraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebioAn8GraphGraphicsScale 8 } wtWebioAn8GraphGraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Maximum." ::= { wtWebioAn8GraphGraphicsScale 9 } wtWebioAn8GraphGraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Maximum." ::= { wtWebioAn8GraphGraphicsScale 10 } wtWebioAn8GraphGraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebioAn8GraphGraphicsScale 11 } wtWebioAn8GraphGraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebioAn8GraphGraphicsScale 12 } wtWebioAn8GraphGraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Unit." ::= { wtWebioAn8GraphGraphicsScale 13 } wtWebioAn8GraphGraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Unit." ::= { wtWebioAn8GraphGraphicsScale 14 } -- wtWebioAn8GraphPorts Group ---------------------------- -- Table wtWebioAn8GraphPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebioAn8GraphPorts 1 } wtWebioAn8GraphPortEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphPortTable 1 } WtWebioAn8GraphPortEntry ::= SEQUENCE { wtWebioAn8GraphPortName OCTET STRING, wtWebioAn8GraphPortText OCTET STRING, wtWebioAn8GraphPortOffset1 OCTET STRING, wtWebioAn8GraphPortTemperature1 OCTET STRING, wtWebioAn8GraphPortOffset2 OCTET STRING, wtWebioAn8GraphPortTemperature2 OCTET STRING, wtWebioAn8GraphPortComment OCTET STRING, wtWebioAn8GraphPortSensorSelect OCTET STRING } wtWebioAn8GraphPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebioAn8GraphPortEntry 1 } wtWebioAn8GraphPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebioAn8GraphPortEntry 2 } wtWebioAn8GraphPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1." ::= { wtWebioAn8GraphPortEntry 3 } wtWebioAn8GraphPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphPortEntry 4 } wtWebioAn8GraphPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2." ::= { wtWebioAn8GraphPortEntry 5 } wtWebioAn8GraphPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn8GraphPortEntry 6 } wtWebioAn8GraphPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebioAn8GraphPortEntry 7 } wtWebioAn8GraphPortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binar kodierte Optionen fur Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt" ::= { wtWebioAn8GraphPortEntry 8 } -- wtWebioAn8GraphManufact Group ---------------------------- wtWebioAn8GraphMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioAn8GraphManufact 1 } wtWebioAn8GraphMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioAn8GraphManufact 2 } wtWebioAn8GraphMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioAn8GraphManufact 3 } wtWebioAn8GraphMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioAn8GraphManufact 4 } wtWebioAn8GraphMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioAn8GraphManufact 5 } wtWebioAn8GraphMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioAn8GraphManufact 6 } -- wtWebioAn8GraphDiag Group ---------------------------- wtWebioAn8GraphDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioAn8GraphDiag 1 } wtWebioAn8GraphDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioAn8GraphDiag 2 } wtWebioAn8GraphDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioAn8GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn8GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn8GraphDiagErrorMessage." ::= { wtWebioAn8GraphDiag 3 } wtWebioAn8GraphDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioAn8GraphDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioAn8GraphDiag 4 } wtWebioAn8GraphDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioAn8GraphDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioAn8GraphAlert1 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 11 wtWebioAn8GraphAlert2 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 12 wtWebioAn8GraphAlert3 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 13 wtWebioAn8GraphAlert4 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 14 wtWebioAn8GraphAlert5 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 15 wtWebioAn8GraphAlert6 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 16 wtWebioAn8GraphAlert7 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 17 wtWebioAn8GraphAlert8 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 18 wtWebioAn8GraphAlert9 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 71 wtWebioAn8GraphAlert10 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 72 wtWebioAn8GraphAlert11 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 73 wtWebioAn8GraphAlert12 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 74 wtWebioAn8GraphAlert13 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 75 wtWebioAn8GraphAlert14 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 76 wtWebioAn8GraphAlert15 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 77 wtWebioAn8GraphAlert16 TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 78 wtWebioAn8GraphAlertDiag TRAP-TYPE ENTERPRISE wtWebioAn8Graph VARIABLES { wtWebioAn8GraphDiagErrorIndex, wtWebioAn8GraphDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END