-- ********************************************************************* -- ** -- ** BATM Advanced Communications. -- ** -- ********************************************************************* -- ** Filename: PRVT-LMM-MIB.mib -- ** Project: T-Metro Switches. -- ** Purpose: Private MIB -- ********************************************************************* -- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved. -- WARNING: -- -- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING: -- -- This file is the property of BATM Advanced Communications and contains -- proprietary and confidential information. This file is made -- available to authorized BATM customers on the express -- condition that neither it, nor any of the information contained -- therein, shall be disclosed to third parties or be used for any -- purpose other than to replace, modify or upgrade firmware and/or -- software components of BATM manufactured equipment within the -- authorized customer's network, and that such transfer be -- completed in accordance with the instructions provided by -- BATM. Any other use is strictly prohibited. -- -- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED -- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE -- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED -- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES -- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. -- -- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER -- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS -- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR -- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY -- TO USE, THE SOFTWARE CONTAINED IN THIS FILE. -- -- ---------------------------------------------------------------------------- PRVT-LMM-MIB DEFINITIONS ::= BEGIN IMPORTS ifIndex FROM IF-MIB switch FROM PRVT-SWITCH-MIB Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC; prvtLmmMIB MODULE-IDENTITY LAST-UPDATED "201110110000Z" ORGANIZATION "BATM Advanced Communication" CONTACT-INFO "BATM/Telco Systems Support team Email: For North America: techsupport@telco.com For North Europe: support@batm.de, info@batm.de For the rest of the world: techsupport@telco.com" DESCRIPTION "Initial version. This MIB will configure laser monitoring" REVISION "201110110000Z" DESCRIPTION "Initial release" ::= { switch 172 } prvtLmmNotifications OBJECT IDENTIFIER ::= { prvtLmmMIB 0 } prvtLmmObjects OBJECT IDENTIFIER ::= { prvtLmmMIB 1 } prvtLmmShutdown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable laser monitoring" ::= { prvtLmmObjects 1 } prvtLmmDebug OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable laser monitoring" ::= { prvtLmmObjects 2 } prvtLmmPeriod OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the monitoring interval (sec)." ::= { prvtLmmObjects 3 } prvtLmmTrap OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable sending SNMP traps when thresholds are crossed" ::= { prvtLmmObjects 4 } prvtLmmLog OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable alert notification logging when thresholds are crossed" ::= { prvtLmmObjects 5 } prvtLmmLed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable LED-alert notifications when thresholds are crossed" ::= { prvtLmmObjects 6 } prvtLmmTemperatureHighThreshold OBJECT-TYPE SYNTAX Integer32 (-128..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for global temperature (-128 up to 128). prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold" ::= { prvtLmmObjects 7 } prvtLmmTemperatureLowThreshold OBJECT-TYPE SYNTAX Integer32 (-128..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for global temperature (-128 up to 128). prvtLmmTemperatureHighThreshold must be higher than prvtLmmTemperatureLowThreshold" ::= { prvtLmmObjects 8 } prvtLmmRxPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for global RX-power (-40 up to 8) prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold" ::= { prvtLmmObjects 9 } prvtLmmRxPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the high threshold value for global RX-power (-40 up to 8) prvtLmmRxPowerHighThreshold must be higher than prvtLmmRxPowerLowThreshold" ::= { prvtLmmObjects 10 } prvtLmmTxPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for global RX-power (-40 up to 8) prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold" ::= { prvtLmmObjects 11 } prvtLmmTxPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the high threshold value for global RX-power (-40 up to 8) prvtLmmTxPowerHighThreshold must be higher than prvtLmmTxPowerLowThreshold" ::= { prvtLmmObjects 12 } prvtLmmInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF PrvtLmmInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lmm configuration per ethernet port" ::= { prvtLmmObjects 13 } prvtLmmInterfaceEntry OBJECT-TYPE SYNTAX PrvtLmmInterfaceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Stack table entry" INDEX { ifIndex } ::= { prvtLmmInterfaceTable 1 } PrvtLmmInterfaceEntry ::= SEQUENCE { prvtLmmInterfaceShutdown TruthValue, prvtLmmInterfaceTempLowThreshold Integer32, prvtLmmInterfaceTempHighThreshold Integer32, prvtLmmInterfaceTempValue Integer32, prvtLmmInterfaceTempThresholdLo Integer32, prvtLmmInterfaceTempThresholdHi Integer32, prvtLmmInterfaceTempTestState TruthValue, prvtLmmInterfaceRxPowerLowThreshold Integer32, prvtLmmInterfaceRxPowerHighThreshold Integer32, prvtLmmInterfaceRxPowerValue Integer32, prvtLmmInterfaceRxPowerThresholdRxLo Integer32, prvtLmmInterfaceRxPowerThresholdRxHi Integer32, prvtLmmInterfaceRxPowerTestState TruthValue, prvtLmmInterfaceTxPowerLowThreshold Integer32, prvtLmmInterfaceTxPowerHighThreshold Integer32, prvtLmmInterfaceTxPowerValue Integer32, prvtLmmInterfaceTxPowerThresholdTxLo Integer32, prvtLmmInterfaceTxPowerThresholdTxHi Integer32, prvtLmmInterfaceTxPowerTestState TruthValue, prvtLmmInterfaceOperStatus TruthValue } prvtLmmInterfaceShutdown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable laser monitoring on port" ::= { prvtLmmInterfaceEntry 1 } prvtLmmInterfaceTempLowThreshold OBJECT-TYPE SYNTAX Integer32 (-128..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for port temperature" ::= { prvtLmmInterfaceEntry 2 } prvtLmmInterfaceTempHighThreshold OBJECT-TYPE SYNTAX Integer32 (-128..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the high threshold value for port temperature. Value of prvtLmmInterfaceTempHighThreshold must be greater than prvtLmmInterfaceTempLowThreshold" ::= { prvtLmmInterfaceEntry 3 } prvtLmmInterfaceTempValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display laser Temperature current value" ::= { prvtLmmInterfaceEntry 4 } prvtLmmInterfaceTempThresholdLo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 5 } prvtLmmInterfaceTempThresholdHi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 6 } prvtLmmInterfaceTempTestState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The state test" ::= { prvtLmmInterfaceEntry 7 } prvtLmmInterfaceRxPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for port RX-power." ::= { prvtLmmInterfaceEntry 8 } prvtLmmInterfaceRxPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the high threshold value for port RX-power. Value of prvtLmmInterfaceRxPowerHighThreshold must be greater than prvtLmmInterfaceRxPowerLowThreshold" ::= { prvtLmmInterfaceEntry 9 } prvtLmmInterfaceRxPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display laser Rx Power current value" ::= { prvtLmmInterfaceEntry 10 } prvtLmmInterfaceRxPowerThresholdRxLo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 11 } prvtLmmInterfaceRxPowerThresholdRxHi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 12 } prvtLmmInterfaceRxPowerTestState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The state test" ::= { prvtLmmInterfaceEntry 13 } prvtLmmInterfaceTxPowerLowThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the low threshold value for port TX-power" ::= { prvtLmmInterfaceEntry 14 } prvtLmmInterfaceTxPowerHighThreshold OBJECT-TYPE SYNTAX Integer32 (-40..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the high threshold value for port TX-power Value of prvtLmmInterfaceTxPowerHighThreshold must be greater than prvtLmmInterfaceTxPowerLowThreshold" ::= { prvtLmmInterfaceEntry 15 } prvtLmmInterfaceTxPowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display laser Tx Power current value" ::= { prvtLmmInterfaceEntry 16 } prvtLmmInterfaceTxPowerThresholdTxLo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 17 } prvtLmmInterfaceTxPowerThresholdTxHi OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The thresholds read from hardware or set by user" ::= { prvtLmmInterfaceEntry 18 } prvtLmmInterfaceTxPowerTestState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "The state test" ::= { prvtLmmInterfaceEntry 19 } prvtLmmInterfaceOperStatus OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status" ::= { prvtLmmInterfaceEntry 20 } prvtLmmTemperatureThresholdCrossed NOTIFICATION-TYPE OBJECTS { prvtLmmInterfaceTempValue, prvtLmmInterfaceTempThresholdHi, prvtLmmInterfaceTempThresholdLo } STATUS current DESCRIPTION "The prvtLmmTemperatureThresholdCrossed shall be generated when prvtLmmInterfaceTempValue rises above prvtLmmInterfaceTempThresholdHi or falls below prvtLmmInterfaceTempThresholdLo. Also the notification shall be generated when prvtLmmInterfaceTempValue returns to the normal range between prvtLmmInterfaceTempThresholdHi and prvtLmmInterfaceTempThresholdLo." ::= { prvtLmmNotifications 1 } prvtLmmTxPowerThresholdCrossed NOTIFICATION-TYPE OBJECTS { prvtLmmInterfaceTxPowerValue, prvtLmmInterfaceTxPowerThresholdTxHi, prvtLmmInterfaceTxPowerThresholdTxLo } STATUS current DESCRIPTION "The prvtLmmTxPowerThresholdCrossed shall be generated when prvtLmmInterfaceTxPowerValue rises above prvtLmmInterfaceTxPowerThresholdTxHi or falls below prvtLmmInterfaceTxPowerThresholdTxLo. Also the notification shall be generated when prvtLmmInterfaceTxPowerValue returns to the normal range between prvtLmmInterfaceTxPowerThresholdTxHi and prvtLmmInterfaceTxPowerThresholdTxLo." ::= { prvtLmmNotifications 2 } prvtLmmRxPowerThresholdCrossed NOTIFICATION-TYPE OBJECTS { prvtLmmInterfaceRxPowerValue, prvtLmmInterfaceRxPowerThresholdRxHi, prvtLmmInterfaceRxPowerThresholdRxLo } STATUS current DESCRIPTION "The prvtLmmRxPowerThresholdCrossed shall be generated when prvtLmmInterfaceRxPowerValue rises above prvtLmmInterfaceRxPowerThresholdRxHi or falls below prvtLmmInterfaceRxPowerThresholdRxLo. Also the notification shall be generated when prvtLmmInterfaceRxPowerValue returns to the normal range between prvtLmmInterfaceRxPowerThresholdRxHi and prvtLmmInterfaceRxPowerThresholdRxLo." ::= { prvtLmmNotifications 3 } END -- end of module PRVT-LMM-MIB.