-- ========================================================================== -- Copyright (c) 2010-2014 Hewlett-Packard Development Company, L.P. -- -- Description: The purpose of this MIB file is to provide object definition -- of WLAN radio resource management (RRM). -- Reference: -- Version: V1.8 -- History: -- V1.0 2008-07-16 Initial version, created by ChenWei -- V1.1 2009-04-16 modified by WangChunsheng -- Add new table of hpnicfDot11MonitorDetectedDevTable for hpnicfDot11MonitorDetectedGroup. -- Add new table of hpnicfDot11RRMAPCfgTable for hpnicfDot11RRMConfigGroup. -- V1.2 2009-05-07 modified by Wang Shaojie, wangchunsheng -- Add hpnicfDot11APInterfNumThreshhd, hpnicfDot11StaInterfNumThreshhd -- to hpnicfDot11GlobeConfigGroup. -- Modify hpnicfDot11RRMCfgIntrvl -- V1.3 2009-05-07 modified by Wang Shaojie -- Add new node hpnicfDot11MonitorDevSNR to hpnicfDot11MonitorDetectedDevTable -- V1.4 2010-02-22 modified by Wang Chunsheng -- Add new table hpnicfDot11RRMSDRadioGroupTable to hpnicfDot11RRMConfigGroup -- 2010-03-18 Modified by Wang Lu -- Add hpnicfDot11RRMAPCfg2Table -- V1.5 2010-09-21 Modified by wu xiaopeng -- Add new node hpnicfDot11RRMCoChlIntfTrapThhd, hpnicfDot11RRMAdjChlIntfTrapThhd -- to hpnicfDot11RRMAPCfg2Table -- 2011-03-23 Modified by NiuJian -- Add new node hpnicfDot11RrmNbrSSID -- to hpnicfDot11RRMNbrInfoTable -- V1.6 2013-03-23 Modified by GaoFei -- Change SYNTAX of hpnicfDot11RRMCfgPERThres,hpnicfDot11RRMCfgToleranceFctr -- V1.7 2013-09-02 Modified by Zhang Siyu -- Add new table hpnicfDot11RRMRadioNbrInfoTable to hpnicfDot11RRMDetectGroup -- 2013-11-19 Modified by wubin -- Add new node hpnicfDot11RRM11nMultiCastMcs -- to hpnicfDot11RRMGlobalCfgPara -- 2013-12-21 Modified by wubin -- Add new node hpnicfDot11RRM11acMadtMaxNss, hpnicfDot11RRM11acSuptMaxNss, -- hpnicfDot11RRM11acMultiCastNss, hpnicfDot11RRM11acMultiCastVhtMcs -- to hpnicfDot11RRMGlobalCfgPara -- V1.8 2014-05-07 Modified by yubo -- Change SYNTAX of hpnicfDot11RRMCfgIntrfThres. -- ========================================================================== HPN-ICF-DOT11-RRM-MIB DEFINITIONS ::= BEGIN IMPORTS HpnicfDot11RadioType, HpnicfDot11ChannelScopeType, HpnicfDot11RadioElementIndex, HpnicfDot11RadioScopeType, hpnicfDot11APElementIndex FROM HPN-ICF-DOT11-REF-MIB Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI TruthValue, MacAddress, DateAndTime, RowStatus FROM SNMPv2-TC hpnicfDot11, HpnicfDot11ObjectIDType, HpnicfDot11SSIDStringType FROM HPN-ICF-DOT11-REF-MIB; hpnicfDot11RRM MODULE-IDENTITY LAST-UPDATED "201009251800Z" -- Sep 25, 2010 at 18:00 GMT ORGANIZATION "" CONTACT-INFO "" DESCRIPTION "This MIB file is to provide the object definition of WLAN radio resource management (RRM)." REVISION "201009251800Z" -- Sep 25, 2010 at 18:00 GMT DESCRIPTION "Modified to add new nodes." REVISION "201002231800Z" -- Feb 23, 2010 at 18:00 GMT DESCRIPTION "Modified to add new nodes." REVISION "200908012000Z" -- Aug 1, 2009 at 20:00 GMT DESCRIPTION "Modified to add new nodes and new table." REVISION "200905072000Z" -- May 7, 2009 at 20:00 GMT DESCRIPTION "Modified to add new nodes and new table." REVISION "200904172000Z" -- April 17, 2009 at 20:00 GMT DESCRIPTION "Modified to add new table and new group." REVISION "200807141429Z" DESCRIPTION "The initial revision of this MIB module." ::= { hpnicfDot11 8 } -- -- Node definitions -- hpnicfDot11RRMConfigGroup OBJECT IDENTIFIER ::= { hpnicfDot11RRM 1 } hpnicfDot11RRMGlobalCfgPara OBJECT IDENTIFIER ::= { hpnicfDot11RRMConfigGroup 1 } hpnicfDot11RRM11nMadtMaxMcs OBJECT-TYPE SYNTAX Integer32 (0..76 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum modulation and coding scheme (MCS) index for 802.11n mandatory rates. The value 255 indicates that no maximum MCS index is specified. No maximum MCS index is specified for 802.11n mandatory rates by default. Besides 255, the specified maximum MCS index for 802.11n supported rates must be no less than the specified maximum MCS index for 802.11n mandatory rates." DEFVAL { 255 } ::= { hpnicfDot11RRMGlobalCfgPara 1 } hpnicfDot11RRM11nSuptMaxMcs OBJECT-TYPE SYNTAX Integer32 (0..76) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum Modulation and Coding Scheme (MCS) index for 802.11n supported rates. The specified maximum MCS index for 802.11n supported rates must be no less than the specified maximum MCS index for 802.11n mandatory rates." DEFVAL { 76 } ::= { hpnicfDot11RRMGlobalCfgPara 2 } hpnicfDot11RRM11gProtect OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable dot11g protection." DEFVAL { false } ::= { hpnicfDot11RRMGlobalCfgPara 3 } hpnicfDot11RRM11aPwrConstrt OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the power constraint for all 802.11a radios. The configured power constraint is advertised in beacons if spectrum management is enabled. The range of power constraint is 0 to MAX-POWER-1 (where the MAX-POWER is defined by the regulatory domain)." DEFVAL { 0 } ::= { hpnicfDot11RRMGlobalCfgPara 4 } hpnicfDot11RRM11aSpectrumManag OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable spectrum management for 802.11a radios. When spectrum management is enabled, the WLAN sub-system advertises power capabilities of the AP and power constraints applicable to all devices in the BSS based on regulatory domain specification." DEFVAL { false } ::= { hpnicfDot11RRMGlobalCfgPara 5 } hpnicfDot11RRMAutoChlAvoid11h OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the auto-channel set as non-dot11h channels, this is, only the non-dot11h channels belonging to the country code are scanned during initial channel selection and one of them is selected." DEFVAL { false } ::= { hpnicfDot11RRMGlobalCfgPara 6 } hpnicfDot11RRMScanChl OBJECT-TYPE SYNTAX INTEGER { auto(1), all(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the scan mode. auto: When this option is set, all channels of the country code being set are scanned. all: When this option is set, all the channels of the radio band are scanned." DEFVAL { auto } ::= { hpnicfDot11RRMGlobalCfgPara 7 } hpnicfDot11RRMScanRptIntvel OBJECT-TYPE SYNTAX Integer32 (5..120) UNITS "second" MAX-ACCESS read-write STATUS current DESCRIPTION "Set the scan report interval." DEFVAL { 10 } ::= { hpnicfDot11RRMGlobalCfgPara 8 } hpnicfDot11APInterfNumThreshhd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of AP interference . If the value of AP interference exceeds this threshold, AP interference trap will be sent. If the value of this node is zero, AP interference trap will be sent immediately." DEFVAL { 0 } ::= { hpnicfDot11RRMGlobalCfgPara 9 } hpnicfDot11StaInterfNumThreshhd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of STA interference. If the value of STA interference exceeds this threshold, STA interference trap will be sent. If the value of this node is zero, STA interference trap will be sent immediately. " DEFVAL { 0 } ::= { hpnicfDot11RRMGlobalCfgPara 10 } hpnicfDot11RRM11nMultiCastMcs OBJECT-TYPE SYNTAX Unsigned32 (0..76 | 4294967295) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the modulation and coding scheme (MCS) index for 802.11n multicast rates. The value 4294967295 indicates that no MCS index is specified. No MCS index is specified for 802.11n multicast rates by default. Besides 4294967295, the specified MCS index for 802.11n multicast rates must be no less than the specified maximum MCS index for 802.11n mandatory rates. Before configure the MCS index for 802.11n multicast rates, the maximum MCS index for 802.11n mandatory rates must be configured" DEFVAL { 4294967295 } ::= { hpnicfDot11RRMGlobalCfgPara 11 } hpnicfDot11RRM11acMadtMaxNss OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum NSS index for 802.11ac mandatory rates. The value 0 indicates that no maximum NSS index is specified. No maximum NSS index is specified for 802.11ac mandatory rates by default. The specified maximum NSS index for 802.11ac supported rates must be no less than the specified maximum NSS index for 802.11ac mandatory rates." DEFVAL { 0 } ::= { hpnicfDot11RRMGlobalCfgPara 12 } hpnicfDot11RRM11acSuptMaxNss OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the maximum NSS index for 802.11ac supported rates. The specified maximum NSS index for 802.11ac supported rates must be no less than the specified maximum NSS index for 802.11ac mandatory rates." DEFVAL { 8 } ::= { hpnicfDot11RRMGlobalCfgPara 13 } hpnicfDot11RRM11acMultiCastNss OBJECT-TYPE SYNTAX Integer32 (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the NSS index for 802.11ac multicast rates. The value 0 indicates that no NSS index is specified. No NSS index is specified for 802.11ac multicast rates by default. The specified NSS index for 802.11ac multicast rates must be no less than the specified maximum NSS index for 802.11ac mandatory rates. Before configuring the NSS index for 802.11ac multicast rates, the maximum NSS index for 802.11ac mandatory rates must be configured. Besides, it must be configured together with the node below." DEFVAL { 0 } ::= { hpnicfDot11RRMGlobalCfgPara 14 } hpnicfDot11RRM11acMultiCastVhtMcs OBJECT-TYPE SYNTAX Integer32 (0..9 | 255) MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the MCS index for 802.11ac multicast rates. The value 255 indicates that no MCS index is specified. No MCS index is specified for 802.11ac multicast rates by default. Besides, it must be configured together with the node above." DEFVAL { 255 } ::= { hpnicfDot11RRMGlobalCfgPara 15 } hpnicfDot11RRMRadioCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMRadioCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configure WLAN RRM based radio type. When 802.11b parameter is modified, 802.11g parameter will be changed at the same time. In the same way, when 802.11g parameter is modified, 802.11b parameter will be changed at the same time." ::= { hpnicfDot11RRMConfigGroup 2 } hpnicfDot11RRMRadioCfgEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMRadioCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configure WLAN RRM based radio type. When 802.11b parameter is modified, 802.11g parameter will be changed at the same time. In the same way, when 802.11g parameter is modified, 802.11b parameter will be changed at the same time." INDEX { hpnicfDot11RRMRadioType } ::= { hpnicfDot11RRMRadioCfgTable 1 } HpnicfDot11RRMRadioCfgEntry ::= SEQUENCE { hpnicfDot11RRMRadioType HpnicfDot11RadioType, hpnicfDot11RRMCfgChlState TruthValue, hpnicfDot11RRMCfgChlMode INTEGER, hpnicfDot11RRMChlProntoRadioElmt Unsigned32, hpnicfDot11RRMCfgPwrState TruthValue, hpnicfDot11RRMCfgPwrMode INTEGER, hpnicfDot11RRMPwrProntoRadioElmt Unsigned32, hpnicfDot11RRMCfgIntrvl Integer32, hpnicfDot11RRMCfgIntrfThres Integer32, hpnicfDot11RRMCfgNoiseThres Integer32, hpnicfDot11RRMCfgPERThres Integer32, hpnicfDot11RRMCfgToleranceFctr Integer32, hpnicfDot11RRMCfgAdjacencyFctr Integer32 } hpnicfDot11RRMRadioType OBJECT-TYPE SYNTAX HpnicfDot11RadioType MAX-ACCESS not-accessible STATUS current DESCRIPTION "802.11 radio type." ::= { hpnicfDot11RRMRadioCfgEntry 1 } hpnicfDot11RRMCfgChlState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable dynamic channel selection." DEFVAL { false } ::= { hpnicfDot11RRMRadioCfgEntry 2 } hpnicfDot11RRMCfgChlMode OBJECT-TYPE SYNTAX INTEGER { selfDecisive(1), userTriggered(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the mode of channel selection. This node can be configured only when dynamic channel selection is enabled." DEFVAL { userTriggered } ::= { hpnicfDot11RRMRadioCfgEntry 3 } hpnicfDot11RRMChlProntoRadioElmt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the AP and radio that will change channel at next calibration cycle. 0 is returned when getting the value of this node. This node can be configured only when the mode of channel selection control is user-triggered. When configuring, the higher 24 bits stand for the AP index, and the last 8 bits stand for the radio index. 4294967295 stand for configuring each radio on all APs." DEFVAL { 0 } ::= { hpnicfDot11RRMRadioCfgEntry 4 } hpnicfDot11RRMCfgPwrState OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable dynamic power selection for the band." DEFVAL { false } ::= { hpnicfDot11RRMRadioCfgEntry 5 } hpnicfDot11RRMCfgPwrMode OBJECT-TYPE SYNTAX INTEGER { selfDecisive(1), userTriggered(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the mode of transmit power control. This node can be configured only when dynamic power selection is enabled." DEFVAL { userTriggered } ::= { hpnicfDot11RRMRadioCfgEntry 6 } hpnicfDot11RRMPwrProntoRadioElmt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specify the AP and radio that will change power at next calibration cycle. 0 is returned when getting the value of this node. This node can be configured only when the mode of transmit power control is user-triggered. When configuring, the higher 24 bits stand for the AP index, and the last 8 bits stand for the radio index. 4294967295 stand for configuring each radio on all APs." DEFVAL { 0 } ::= { hpnicfDot11RRMRadioCfgEntry 7 } hpnicfDot11RRMCfgIntrvl OBJECT-TYPE SYNTAX Integer32 UNITS "minute" MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the calibration interval." DEFVAL { 8 } ::= { hpnicfDot11RRMRadioCfgEntry 8 } hpnicfDot11RRMCfgIntrfThres OBJECT-TYPE SYNTAX Integer32 (1..100) UNITS "percent" MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the interface threshold. By default, interference observed on an operating channel is considered during dynamic frequency selection and transmit power control. If the interference percentage on the channel reaches the set threshold, RRM will perform resource adjustment to control the situation." DEFVAL { 50 } ::= { hpnicfDot11RRMRadioCfgEntry 9 } hpnicfDot11RRMCfgNoiseThres OBJECT-TYPE SYNTAX Integer32 (-127..127) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the noise threshold." DEFVAL { -70 } ::= { hpnicfDot11RRMRadioCfgEntry 10 } hpnicfDot11RRMCfgPERThres OBJECT-TYPE SYNTAX Integer32 (1..100) UNITS "percent" MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the CRC error threshold. If the percentage of CRC errors reaches the threshold, RRM will perform resource adjustment to control the situation." DEFVAL { 20 } ::= { hpnicfDot11RRMRadioCfgEntry 11 } hpnicfDot11RRMCfgToleranceFctr OBJECT-TYPE SYNTAX Integer32 (1..45) UNITS "percent" MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the tolerance level. During dynamic frequency selection (DFS), the channel will be changed only if there is a better channel having lesser interference and packet error rate than those specified by the user." DEFVAL { 20 } ::= { hpnicfDot11RRMRadioCfgEntry 12 } hpnicfDot11RRMCfgAdjacencyFctr OBJECT-TYPE SYNTAX Integer32 (1..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Configure the adjacency factor for the band. If transmit power control (TPC) is configured, power will be adjusted when the nth neighbor is detected. The value n is the adjacency factor." DEFVAL { 3 } ::= { hpnicfDot11RRMRadioCfgEntry 13 } hpnicfDot11RRMAPCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMAPCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the RRM parameters for AP." ::= { hpnicfDot11RRMConfigGroup 3 } hpnicfDot11RRMAPCfgEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMAPCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of RRM parameters for AP." INDEX { hpnicfDot11APElementIndex } ::= { hpnicfDot11RRMAPCfgTable 1 } HpnicfDot11RRMAPCfgEntry ::= SEQUENCE { hpnicfDot11RRMAPWorkMode INTEGER } hpnicfDot11RRMAPWorkMode OBJECT-TYPE SYNTAX INTEGER { normal(1), monitor(2), hybrid(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "AP work mode." ::= { hpnicfDot11RRMAPCfgEntry 1 } hpnicfDot11RRMSDRadioGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMSDRadioGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines RRM self-decisive radio group." ::= { hpnicfDot11RRMConfigGroup 4 } hpnicfDot11RRMSDRadioGroupEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMSDRadioGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of one RRM self-decisive radio group." INDEX { hpnicfDot11RRMSDRadioGroupId } ::= { hpnicfDot11RRMSDRadioGroupTable 1 } HpnicfDot11RRMSDRadioGroupEntry ::= SEQUENCE { hpnicfDot11RRMSDRadioGroupId Unsigned32, hpnicfDot11RRMSDRadioGroupDesc OCTET STRING, hpnicfDot11RRMSDRdGrpChlHolddownTm Unsigned32, hpnicfDot11RRMSDRdGrpPwrHolddownTm Unsigned32, hpnicfDot11RRMSDRdGroupRowStatus RowStatus } hpnicfDot11RRMSDRadioGroupId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents RRM self-decisive radio group ID." ::= { hpnicfDot11RRMSDRadioGroupEntry 1 } hpnicfDot11RRMSDRadioGroupDesc OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "Represents the description of RRM self-decisive radio group." ::= { hpnicfDot11RRMSDRadioGroupEntry 2 } hpnicfDot11RRMSDRdGrpChlHolddownTm OBJECT-TYPE SYNTAX Unsigned32 UNITS "minute" MAX-ACCESS read-create STATUS current DESCRIPTION "Represents the channel holddown time of RRM self-decisive radio group." ::= { hpnicfDot11RRMSDRadioGroupEntry 3 } hpnicfDot11RRMSDRdGrpPwrHolddownTm OBJECT-TYPE SYNTAX Unsigned32 UNITS "minute" MAX-ACCESS read-create STATUS current DESCRIPTION "Represents the power holddown time of RRM self-decisive radio group." ::= { hpnicfDot11RRMSDRadioGroupEntry 4 } hpnicfDot11RRMSDRdGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of this table entry." ::= { hpnicfDot11RRMSDRadioGroupEntry 5 } hpnicfDot11RRMAPCfg2Table OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMAPCfg2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table defines the RRM parameters for AP." ::= { hpnicfDot11RRMConfigGroup 5 } hpnicfDot11RRMAPCfg2Entry OBJECT-TYPE SYNTAX HpnicfDot11RRMAPCfg2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of RRM parameters for AP." INDEX { hpnicfDot11RRMAPSerialID } ::= { hpnicfDot11RRMAPCfg2Table 1 } HpnicfDot11RRMAPCfg2Entry ::= SEQUENCE { hpnicfDot11RRMAPSerialID HpnicfDot11ObjectIDType, hpnicfDot11RRMAPIntfThreshold Integer32, hpnicfDot11RRMStaIntfThreshold Integer32, hpnicfDot11RRMCoChlIntfTrapThhd Integer32, hpnicfDot11RRMAdjChlIntfTrapThhd Integer32 } hpnicfDot11RRMAPSerialID OBJECT-TYPE SYNTAX HpnicfDot11ObjectIDType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serial ID of the AP." ::= { hpnicfDot11RRMAPCfg2Entry 1 } hpnicfDot11RRMAPIntfThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of AP interference . If the number of AP interference exceeds this threshold, AP interference trap will be sent." ::= { hpnicfDot11RRMAPCfg2Entry 2 } hpnicfDot11RRMStaIntfThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of STA interference. If the number of STA interference exceeds this threshold, station interference trap will be sent." ::= { hpnicfDot11RRMAPCfg2Entry 3 } hpnicfDot11RRMCoChlIntfTrapThhd OBJECT-TYPE SYNTAX Integer32 UNITS "dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of interference trap with current ap. If signal strength of the device exceeds this threshold, corresponding trap will be sent." ::= { hpnicfDot11RRMAPCfg2Entry 4 } hpnicfDot11RRMAdjChlIntfTrapThhd OBJECT-TYPE SYNTAX Integer32 UNITS "dbm" MAX-ACCESS read-write STATUS current DESCRIPTION "Represents threshold of adjacent interference trap with current ap. If signal strength of the device exceeds this threshold, corresponding trap will be sent." ::= { hpnicfDot11RRMAPCfg2Entry 5 } hpnicfDot11RRMDetectGroup OBJECT IDENTIFIER ::= { hpnicfDot11RRM 2 } hpnicfDot11RRMChlRptTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMChlRptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the RRM channel information of each radio on all APs." ::= { hpnicfDot11RRMDetectGroup 1 } hpnicfDot11RRMChlRptEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMChlRptEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of RRM channel information of the radio on the AP." INDEX { hpnicfDot11RRMRadioIndex, hpnicfDot11RRMChlRptChlNum } ::= { hpnicfDot11RRMChlRptTable 1 } HpnicfDot11RRMChlRptEntry ::= SEQUENCE { hpnicfDot11RRMRadioIndex HpnicfDot11RadioElementIndex, hpnicfDot11RRMChlRptChlNum Integer32, hpnicfDot11RRMChlRptChlType INTEGER, hpnicfDot11RRMChlRptChlQlty INTEGER, hpnicfDot11RRMChlRptNbrCnt Integer32, hpnicfDot11RRMChlRptLoad Integer32, hpnicfDot11RRMChlRptUtlz Integer32, hpnicfDot11RRMChlRptIntrf Integer32, hpnicfDot11RRMChlRptPER Integer32, hpnicfDot11RRMChlRptRetryRate Integer32, hpnicfDot11RRMChlRptNoise Integer32, hpnicfDot11RRMChlRptRadarIndtcr INTEGER } hpnicfDot11RRMRadioIndex OBJECT-TYPE SYNTAX HpnicfDot11RadioElementIndex MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Represents index of the radio." ::= { hpnicfDot11RRMChlRptEntry 1 } hpnicfDot11RRMChlRptChlNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Channel number." ::= { hpnicfDot11RRMChlRptEntry 2 } hpnicfDot11RRMChlRptChlType OBJECT-TYPE SYNTAX INTEGER { primeChannel(1), offChannel(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Channel type." ::= { hpnicfDot11RRMChlRptEntry 3 } hpnicfDot11RRMChlRptChlQlty OBJECT-TYPE SYNTAX INTEGER { good(1), bad(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Channel quality." ::= { hpnicfDot11RRMChlRptEntry 4 } hpnicfDot11RRMChlRptNbrCnt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of neighbors found on the channel." ::= { hpnicfDot11RRMChlRptEntry 5 } hpnicfDot11RRMChlRptLoad OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Load observed on the channel in percentage." ::= { hpnicfDot11RRMChlRptEntry 6 } hpnicfDot11RRMChlRptUtlz OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Utilization of the channel in percentage." ::= { hpnicfDot11RRMChlRptEntry 7 } hpnicfDot11RRMChlRptIntrf OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Interference observed on the channel in percentage." ::= { hpnicfDot11RRMChlRptEntry 8 } hpnicfDot11RRMChlRptPER OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Packet error rate observed on the channel in percentage." ::= { hpnicfDot11RRMChlRptEntry 9 } hpnicfDot11RRMChlRptRetryRate OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of retransmission happened on the channel." ::= { hpnicfDot11RRMChlRptEntry 10 } hpnicfDot11RRMChlRptNoise OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Noise observed on the channel." ::= { hpnicfDot11RRMChlRptEntry 11 } hpnicfDot11RRMChlRptRadarIndtcr OBJECT-TYPE SYNTAX INTEGER { detected(1), notDetected(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Radar detection status." ::= { hpnicfDot11RRMChlRptEntry 12 } hpnicfDot11RRMNbrInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMNbrInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the RRM neighbor information of each radio on all APs." ::= { hpnicfDot11RRMDetectGroup 2 } hpnicfDot11RRMNbrInfoEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMNbrInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of RRM neighbor information of the radio on an AP." INDEX { hpnicfDot11RRMRadioIndex, hpnicfDot11RrmNbrBSSID } ::= { hpnicfDot11RRMNbrInfoTable 1 } HpnicfDot11RRMNbrInfoEntry ::= SEQUENCE { hpnicfDot11RrmNbrBSSID MacAddress, hpnicfDot11RrmNbrChl HpnicfDot11ChannelScopeType, hpnicfDot11RRMNbrIntrf Integer32, hpnicfDot11RrmNbrRSSI Integer32, hpnicfDot11RrmNbrType INTEGER, hpnicfDot11RrmNbrSSID HpnicfDot11SSIDStringType } hpnicfDot11RrmNbrBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "MAC address of the AP." ::= { hpnicfDot11RRMNbrInfoEntry 1 } hpnicfDot11RrmNbrChl OBJECT-TYPE SYNTAX HpnicfDot11ChannelScopeType MAX-ACCESS read-only STATUS current DESCRIPTION "Channel number on which the neighbor was found." ::= { hpnicfDot11RRMNbrInfoEntry 2 } hpnicfDot11RRMNbrIntrf OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Interference observed on the channel in percentage by neighbor." ::= { hpnicfDot11RRMNbrInfoEntry 3 } hpnicfDot11RrmNbrRSSI OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Signal strength of the AP in dBm." ::= { hpnicfDot11RRMNbrInfoEntry 4 } hpnicfDot11RrmNbrType OBJECT-TYPE SYNTAX INTEGER { managed(1), unmanaged(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of the AP, managed or unmanaged." ::= { hpnicfDot11RRMNbrInfoEntry 5 } hpnicfDot11RrmNbrSSID OBJECT-TYPE SYNTAX HpnicfDot11SSIDStringType MAX-ACCESS read-only STATUS current DESCRIPTION "SSID of the Neighbor." ::= { hpnicfDot11RRMNbrInfoEntry 6 } hpnicfDot11RRMHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the details of the latest three channel changes and power changes applied on all APs, including time of change, reason of the change and the channel, power, interference parameters." ::= { hpnicfDot11RRMDetectGroup 3 } hpnicfDot11RRMHistoryEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry shows the details of channel and power changes." INDEX { hpnicfDot11RRMRadioIndex, hpnicfDot11RRMHistoryId, hpnicfDot11RRMHistoryRecIndctr } ::= { hpnicfDot11RRMHistoryTable 1 } HpnicfDot11RRMHistoryEntry ::= SEQUENCE { hpnicfDot11RRMHistoryId Integer32, hpnicfDot11RRMHistoryRecIndctr INTEGER, hpnicfDot11RRMHistoryChl HpnicfDot11ChannelScopeType, hpnicfDot11RRMHistoryPwr Integer32, hpnicfDot11RRMHistoryLoad Integer32, hpnicfDot11RRMHistoryUtlz Integer32, hpnicfDot11RRMHistoryIntrf Integer32, hpnicfDot11RRMHistoryNoise Integer32, hpnicfDot11RRMHistoryPER Integer32, hpnicfDot11RRMHistoryRetryRate Integer32, hpnicfDot11RRMHistoryChgReason BITS, hpnicfDot11RRMHistoryChgDateTime DateAndTime } hpnicfDot11RRMHistoryId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "History number of the change." ::= { hpnicfDot11RRMHistoryEntry 1 } hpnicfDot11RRMHistoryRecIndctr OBJECT-TYPE SYNTAX INTEGER { before(1), after(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "History record type of the change." ::= { hpnicfDot11RRMHistoryEntry 2 } hpnicfDot11RRMHistoryChl OBJECT-TYPE SYNTAX HpnicfDot11ChannelScopeType MAX-ACCESS read-only STATUS current DESCRIPTION "Channel on which the radio operates before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 3 } hpnicfDot11RRMHistoryPwr OBJECT-TYPE SYNTAX Integer32 UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "Power of the radio before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 4 } hpnicfDot11RRMHistoryLoad OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Load observed on the radio in percentage before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 5 } hpnicfDot11RRMHistoryUtlz OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Utilization of the radio in percentage before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 6 } hpnicfDot11RRMHistoryIntrf OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Interference observed on the radio in percentage before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 7 } hpnicfDot11RRMHistoryNoise OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Noise observed on the radio before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 8 } hpnicfDot11RRMHistoryPER OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Packet error rate observed on the radio in percentage before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 9 } hpnicfDot11RRMHistoryRetryRate OBJECT-TYPE SYNTAX Integer32 (0..100) UNITS "percent" MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of retransmission happened on the radio before/after the change of channel or power." ::= { hpnicfDot11RRMHistoryEntry 10 } hpnicfDot11RRMHistoryChgReason OBJECT-TYPE SYNTAX BITS { others(0), coverage(1), radar(2), retransmission(3), packetsDiscarded(4), interference(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Reason for the change of channel or power. The various bit positions are: |0 |Others | |1 |Coverage | |2 |Radar | |3 |Retransmission | |4 |Packets discarded | |5 |Interference | 0 is returned when the history record type is after." ::= { hpnicfDot11RRMHistoryEntry 11 } hpnicfDot11RRMHistoryChgDateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time when the channel or power change occurred." ::= { hpnicfDot11RRMHistoryEntry 12 } hpnicfDot11RRMRadioNbrInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11RRMRadioNbrInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the RRM neighbor information of each radio on all APs." ::= { hpnicfDot11RRMDetectGroup 4 } hpnicfDot11RRMRadioNbrInfoEntry OBJECT-TYPE SYNTAX HpnicfDot11RRMRadioNbrInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of RRM neighbor information of the radio on an AP." INDEX { hpnicfDot11RRMRadioNbrAPID, hpnicfDot11RRMRadioNbrRadioID } ::= { hpnicfDot11RRMRadioNbrInfoTable 1 } HpnicfDot11RRMRadioNbrInfoEntry ::= SEQUENCE { hpnicfDot11RRMRadioNbrAPID HpnicfDot11ObjectIDType, hpnicfDot11RRMRadioNbrRadioID HpnicfDot11RadioScopeType, hpnicfDot11RRMRadioNbrSSID OCTET STRING } hpnicfDot11RRMRadioNbrAPID OBJECT-TYPE SYNTAX HpnicfDot11ObjectIDType MAX-ACCESS not-accessible STATUS current DESCRIPTION "AP serial id." ::= { hpnicfDot11RRMRadioNbrInfoEntry 1 } hpnicfDot11RRMRadioNbrRadioID OBJECT-TYPE SYNTAX HpnicfDot11RadioScopeType MAX-ACCESS not-accessible STATUS current DESCRIPTION "Radio Id on AP." ::= { hpnicfDot11RRMRadioNbrInfoEntry 2 } hpnicfDot11RRMRadioNbrSSID OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "All neighbour SSIDs scanned by the selected radio." ::= { hpnicfDot11RRMRadioNbrInfoEntry 3 } hpnicfDot11RRMNotifyGroup OBJECT IDENTIFIER ::= { hpnicfDot11RRM 3 } hpnicfDot11RRMChlQltyNotifications OBJECT IDENTIFIER ::= { hpnicfDot11RRMNotifyGroup 1 } hpnicfDot11RRMChlQltyNtfPrefix OBJECT IDENTIFIER ::= { hpnicfDot11RRMChlQltyNotifications 0 } hpnicfDot11RRMIntrfLimit NOTIFICATION-TYPE OBJECTS { hpnicfDot11RRMChlRptIntrf } STATUS current DESCRIPTION "This notification will be sent when interference on the radio exceeds the limit." ::= { hpnicfDot11RRMChlQltyNtfPrefix 1 } hpnicfDot11RRMPERLimit NOTIFICATION-TYPE OBJECTS { hpnicfDot11RRMChlRptPER } STATUS current DESCRIPTION "This notification will be sent when packet error rate on the radio exceeds the limit." ::= { hpnicfDot11RRMChlQltyNtfPrefix 2 } hpnicfDot11RRMNoiseLimit NOTIFICATION-TYPE OBJECTS { hpnicfDot11RRMChlRptNoise } STATUS current DESCRIPTION "This notification will be sent when noise on the radio exceeds the limit." ::= { hpnicfDot11RRMChlQltyNtfPrefix 3 } hpnicfDot11RRMResChgNotifications OBJECT IDENTIFIER ::= { hpnicfDot11RRMNotifyGroup 2 } hpnicfDot11RRMResChgNtfPrefix OBJECT IDENTIFIER ::= { hpnicfDot11RRMResChgNotifications 0 } hpnicfDot11RRMPowerChange NOTIFICATION-TYPE OBJECTS { hpnicfDot11RRMRadioIndex, hpnicfDot11NewPower, hpnicfDot11OldPower } STATUS current DESCRIPTION "This notification will be sent when power changed on the radio automatically." ::= { hpnicfDot11RRMResChgNtfPrefix 1 } hpnicfDot11RRMNotificationsVar OBJECT IDENTIFIER ::= { hpnicfDot11RRMNotifyGroup 3 } hpnicfDot11NewPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Power of the radio after the change of power." ::= { hpnicfDot11RRMNotificationsVar 1 } hpnicfDot11OldPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Power of the radio before the change of power." ::= { hpnicfDot11RRMNotificationsVar 2 } hpnicfDot11MonitorDetectedGroup OBJECT IDENTIFIER ::= { hpnicfDot11RRM 4 } hpnicfDot11MonitorDetectedDevTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfDot11MonitorDetectedDevEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table shows the devices of AP detected" ::= { hpnicfDot11MonitorDetectedGroup 1 } hpnicfDot11MonitorDetectedDevEntry OBJECT-TYPE SYNTAX HpnicfDot11MonitorDetectedDevEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry contains information of detected devices." INDEX { hpnicfDot11MonitorDevMAC, hpnicfDot11APElementIndex } ::= { hpnicfDot11MonitorDetectedDevTable 1 } HpnicfDot11MonitorDetectedDevEntry ::= SEQUENCE { hpnicfDot11MonitorDevMAC MacAddress, hpnicfDot11MonitorDevType INTEGER, hpnicfDot11MonitorDevVendor OCTET STRING, hpnicfDot11MonitorDevSSID OCTET STRING, hpnicfDot11MonitorDevBSSID MacAddress, hpnicfDot11MonitorDevChannel HpnicfDot11ChannelScopeType, hpnicfDot11MonitorRadioId HpnicfDot11RadioScopeType, hpnicfDot11MonitorDevMaxRSSI Integer32, hpnicfDot11MonitorDevBeaconIntvl Integer32, hpnicfDot11MonitorDevFstDctTime DateAndTime, hpnicfDot11MonitorDevLstDctTime DateAndTime, hpnicfDot11MonitorDevClear TruthValue, hpnicfDot11MonitorDevSNR Integer32 } hpnicfDot11MonitorDevMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "Represents MAC address of the device detected." ::= { hpnicfDot11MonitorDetectedDevEntry 1 } hpnicfDot11MonitorDevType OBJECT-TYPE SYNTAX INTEGER { client(1), ap(2), adhoc(3), wirelessBridge(4), unknown(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Represents type of the device detected." ::= { hpnicfDot11MonitorDetectedDevEntry 2 } hpnicfDot11MonitorDevVendor OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Represents vendor of the detected device." ::= { hpnicfDot11MonitorDetectedDevEntry 3 } hpnicfDot11MonitorDevSSID OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the service set identifier for the ESS of the device which type is ap or adhoc." ::= { hpnicfDot11MonitorDetectedDevEntry 4 } hpnicfDot11MonitorDevBSSID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the basic service set identifier of the detected device." ::= { hpnicfDot11MonitorDetectedDevEntry 5 } hpnicfDot11MonitorDevChannel OBJECT-TYPE SYNTAX HpnicfDot11ChannelScopeType MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the channel in which the device was last detected. AP will choose the channel which has maximum signal strength as effective channel, as there is interference between adjacent channels." ::= { hpnicfDot11MonitorDetectedDevEntry 6 } hpnicfDot11MonitorRadioId OBJECT-TYPE SYNTAX HpnicfDot11RadioScopeType MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the radio ID of the AP that detected the device." ::= { hpnicfDot11MonitorDetectedDevEntry 7 } hpnicfDot11MonitorDevMaxRSSI OBJECT-TYPE SYNTAX Integer32 UNITS "dbm" MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the maximum detected RSSI of the device in a scan report cycle." ::= { hpnicfDot11MonitorDetectedDevEntry 8 } hpnicfDot11MonitorDevBeaconIntvl OBJECT-TYPE SYNTAX Integer32 UNITS "millisecond" MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the beacon interval for the detected device(not include the device which type is client)." ::= { hpnicfDot11MonitorDetectedDevEntry 9 } hpnicfDot11MonitorDevFstDctTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the time at which the device was first detected." ::= { hpnicfDot11MonitorDetectedDevEntry 10 } hpnicfDot11MonitorDevLstDctTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the time at which the device was detected last time." ::= { hpnicfDot11MonitorDetectedDevEntry 11 } hpnicfDot11MonitorDevClear OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to clear the information of the device detected in the WLAN. It will return false for get operation." ::= { hpnicfDot11MonitorDetectedDevEntry 12 } hpnicfDot11MonitorDevSNR OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Represents the SNR of the device in a scan report cycle." ::= { hpnicfDot11MonitorDetectedDevEntry 13 } END