HP-SwitchStack-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, IpAddress FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF RowStatus, MacAddress FROM SNMPv2-TC hpSwitch FROM HP-ICF-OID; hpSwitchVirtualStackMib MODULE-IDENTITY LAST-UPDATED "201010291946Z" -- October 29, 2010 ORGANIZATION "HP Networking" CONTACT-INFO "Hewlett Packard Company 8000 Foothills Blvd. Roseville, CA 95747" DESCRIPTION "This MIB module describes objects for managing the Stacking features of devices in the HP Integrated Communication Facility product line." REVISION "201010291946Z" -- October 29, 2010 DESCRIPTION "Added hpSwitchStackMemberPasswordLong to hpSwitchStackConfigMemberEntry." REVISION "200011032344Z" -- November 3, 2000 DESCRIPTION "Initial version of this MIB module." ::= { hpSwitch 10 } -- Configuration support for Stacking hpSwitchStackConfig OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 1 } hpSwitchStackAdminStatus OBJECT-TYPE SYNTAX INTEGER { candidate(1), disabled(2), member(3), command(4), pending(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "The operational status of the stacking feature." ::= { hpSwitchStackConfig 1 } hpSwitchStackCommandAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is only valid if 'hpSwitchStackAdminStatus' has been set 'member'. This is the MAC address of the command switch for this member." ::= { hpSwitchStackConfig 2 } hpSwitchStackName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable is only valid if 'hpSwitchStackAdminStatus' has been set 'command-switch'. This is the name of the stack for which this switch is serving as the command switch (maximum length of 20 characters)." ::= { hpSwitchStackConfig 3 } hpSwitchStackPropagate OBJECT-TYPE SYNTAX INTEGER{ enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable SNMP community propagation. This variable is only valid if 'hpSwitchStackAdminStatus' has been set to 'command-switch'." ::= { hpSwitchStackConfig 4 } hpSwitchStackAutoJoin OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable auto join on stack. This variable is only valid for candidate switch." ::= { hpSwitchStackConfig 5 } hpSwitchStackAutoGrab OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable auto grab on stack. This variable is only valid if 'hpSwitchStackAdminStatus' has been set to 'command-switch'." ::= { hpSwitchStackConfig 6 } hpSwitchStackConfigMemberTable OBJECT-TYPE SYNTAX SEQUENCE OF HpSwitchStackConfigMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains a group of member switches configured to be in this switch's stack." ::= { hpSwitchVirtualStackMib 2 } hpSwitchStackConfigMemberEntry OBJECT-TYPE SYNTAX HpSwitchStackConfigMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A group of member switches configured to be in this switch's stack." INDEX { hpSwitchStackMemberSwitchNum } ::= { hpSwitchStackConfigMemberTable 1 } HpSwitchStackConfigMemberEntry ::= SEQUENCE { hpSwitchStackMemberSwitchNum Integer32, hpSwitchStackMemberMacAddr MacAddress, hpSwitchStackMemberPassword OCTET STRING, hpSwitchStackMemberEntryStatus RowStatus, hpSwitchStackMemberPasswordLong OCTET STRING } hpSwitchStackMemberSwitchNum OBJECT-TYPE SYNTAX Integer32 (1..15) MAX-ACCESS read-only STATUS current DESCRIPTION "An index that uniquely identifies the member switch associated with this row entry." ::= { hpSwitchStackConfigMemberEntry 1 } hpSwitchStackMemberMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The MAC Address that identifies the member switch." ::= { hpSwitchStackConfigMemberEntry 2 } hpSwitchStackMemberPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..17)) MAX-ACCESS read-create STATUS deprecated DESCRIPTION "The manager password configured on the member switch. This object represents the first 17 octets of the object hpSwitchStackMemberPasswordLong; reading or writing a value to this object will also read or write hpSwitchStackMemberPasswordLong, truncating the length to 17 octets. This object always returns a 0 length octet string when read." ::= { hpSwitchStackConfigMemberEntry 3 } hpSwitchStackMemberEntryStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of a stack member entry." ::= { hpSwitchStackConfigMemberEntry 4 } hpSwitchStackMemberPasswordLong OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1025)) MAX-ACCESS read-create STATUS current DESCRIPTION "The manager password configured on the member switch. This object always returns a 0 length octet string when read. The exact size of this object is implementation dependent; consult the product documentation to determine the supported size for a specific product." ::= { hpSwitchStackConfigMemberEntry 5 } -- Status support for Stacking hpStackStats OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 3 } hpStackStatsName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "The stack name of this switch." ::= { hpStackStats 1 } hpStackStatsMembersNum OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of member switches that have joined this switch's stack. This variable is only valid if this switch has been set as a 'command-switch'." ::= { hpStackStats 2 } hpStackStatsMembersUnreachable OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of unreachable member switches. This variable is only valid if this switch has been set as a 'command-switch'." ::= { hpStackStats 3 } hpStackStatsMemberID OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The number by which member switch is known on the stack." ::= { hpStackStats 4 } hpStackStatsMgmtIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The IP address of the Stack manager switch (command switch). This variable is only valid if this switch has been set as a 'member-switch'." ::= { hpStackStats 5 } hpStackStatsStackingStatus OBJECT-TYPE SYNTAX INTEGER { joined(1), -- joined successfully pending(2), -- join pending noReponse(3), -- No response from command switch notCommand(4), -- Not a command switch stackFull(5), -- Stack full on command switch remoteFailure(6), -- Unknown remote failure unknownFailure(7), -- Unknown failure evicted(8), -- Evicted by command switch commandUp(9), -- command switch is up commandDown(10), -- command switch is down unusedStatus(11), -- Status not currently used undiscovered(12) -- Undiscovered switch } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of this switch. This variable is only valid if this switch has been set as a 'member-switch'." ::= { hpStackStats 6 } hpStackStatsMembersTable OBJECT-TYPE SYNTAX SEQUENCE OF HpStackStatsMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the member switches that have joined this switch's stack." ::= { hpSwitchVirtualStackMib 4 } hpStackStatsMemberEntry OBJECT-TYPE SYNTAX HpStackStatsMemberEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information associated with each row in the member table." INDEX { hpStackStatsMemberSwitchIndx } ::= { hpStackStatsMembersTable 1 } HpStackStatsMemberEntry ::= SEQUENCE { hpStackStatsMemberSwitchIndx Integer32, hpStackStatsMemberMacAddr MacAddress, hpStackStatsMemberSystemName OCTET STRING, hpStackStatsMemberDeviceType OCTET STRING, hpStackStatsMemberOperStatus INTEGER } hpStackStatsMemberSwitchIndx OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "The index identifying the member switch." ::= { hpStackStatsMemberEntry 1 } hpStackStatsMemberMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the member switch." ::= { hpStackStatsMemberEntry 2 } hpStackStatsMemberSystemName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system name of the member switch." ::= { hpStackStatsMemberEntry 3 } hpStackStatsMemberDeviceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The device type of the member switch." ::= { hpStackStatsMemberEntry 4 } hpStackStatsMemberOperStatus OBJECT-TYPE SYNTAX INTEGER { pending(1), -- join pending joined(2), -- joined noReponse(3), -- No response from -- member switch stackingDisabled(4), -- Stacking disabled invalidPassword(5), -- Invalid password commanderAnotherStack(6), -- Commander of another -- stack remoteFailure(7), -- Remote failure unknownFailure(8), -- Unknown failure rejected(9), -- rejected by command -- switch memberUp(10), -- member switch is up memberDown(11), -- member switch is down commanderThisStack(12), -- Commander of this stack unusedStatus(13), -- Status not currently -- being used undiscovered(14) -- Undiscovered switch } MAX-ACCESS read-only STATUS current DESCRIPTION "The current state of the member switch." ::= { hpStackStatsMemberEntry 5 } -- Configuration support for Discovery Protocol hpSwitchDiscoveryConfig OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 5 } hpSwitchDiscoveryAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The operational status of the discovery protocol." ::= { hpSwitchDiscoveryConfig 1 } hpSwitchDiscoveryTransmissionInterval OBJECT-TYPE SYNTAX Integer32 (1..300) MAX-ACCESS read-write STATUS current DESCRIPTION "The interval between the sending out of new discovery packets." ::= { hpSwitchDiscoveryConfig 2 } -- Status support for Discovery Protocol hpDiscoverStatsCandidatesTable OBJECT-TYPE SYNTAX SEQUENCE OF HpDiscoverStatsCandidateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the switches that have been discovered as a candidate to form a stack." ::= { hpSwitchVirtualStackMib 6 } hpDiscoverStatsCandidateEntry OBJECT-TYPE SYNTAX HpDiscoverStatsCandidateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information associated with each row in the candidate table." INDEX { hpDiscoverStatsCandidateMacAddr } ::= { hpDiscoverStatsCandidatesTable 1 } HpDiscoverStatsCandidateEntry ::= SEQUENCE { hpDiscoverStatsCandidateMacAddr MacAddress, hpDiscoverStatsCandidateSystemName OCTET STRING, hpDiscoverStatsCandidateDeviceType OCTET STRING } hpDiscoverStatsCandidateMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the candidate switch. Used as an index identifying row in the table." ::= { hpDiscoverStatsCandidateEntry 1 } hpDiscoverStatsCandidateSystemName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system name of the candidate switch." ::= { hpDiscoverStatsCandidateEntry 2 } hpDiscoverStatsCandidateDeviceType OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The device type of the candidate switch." ::= { hpDiscoverStatsCandidateEntry 3 } hpDiscoverStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF HpDiscoverStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table containing the switches that have been discovered on the network." ::= { hpSwitchVirtualStackMib 7 } hpDiscoverStatsEntry OBJECT-TYPE SYNTAX HpDiscoverStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information associated with each row in the discover table." INDEX { hpDiscoverStatsSwitchIndex } ::= { hpDiscoverStatsTable 1 } HpDiscoverStatsEntry ::= SEQUENCE { hpDiscoverStatsSwitchIndex Integer32, hpDiscoverStatsSwitchStackName OCTET STRING, hpDiscoverStatsSwitchMacAddr MacAddress, hpDiscoverStatsSwitchSystemName OCTET STRING, hpDiscoverStatsSwitchStatus OCTET STRING } hpDiscoverStatsSwitchIndex OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The index identifying the row in the table." ::= { hpDiscoverStatsEntry 1 } hpDiscoverStatsSwitchStackName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The stack name of the discovered switch." ::= { hpDiscoverStatsEntry 2 } hpDiscoverStatsSwitchMacAddr OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the discovered switch." ::= { hpDiscoverStatsEntry 3 } hpDiscoverStatsSwitchSystemName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The system name of the discovered switch." ::= { hpDiscoverStatsEntry 4 } hpDiscoverStatsSwitchStatus OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..35)) MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the discovered switch." ::= { hpDiscoverStatsEntry 5 } hpSwitchVirtualStackMibConformance OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMib 8 } hpSwitchVirtualStackMibCompliances OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMibConformance 1} hpSwitchVirtualStackMibGroups OBJECT IDENTIFIER ::= { hpSwitchVirtualStackMibConformance 2} hpSwitchVirtualStackMibCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "The compliance statement for devices implementing the HP Stack Mib." MODULE MANDATORY-GROUPS { hpSwitchStackConfigGroup, hpSwitchStackStatsGroup, hpSwitchDiscoverConfigGroup, hpDiscoverStatsGroup } ::= { hpSwitchVirtualStackMibCompliances 1 } hpSwitchVirtualStackMibCompliance1 MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for devices implementing the HP Stack Mib." MODULE MANDATORY-GROUPS { hpSwitchStackConfigGroup1, hpSwitchStackStatsGroup, hpSwitchDiscoverConfigGroup, hpDiscoverStatsGroup } ::= { hpSwitchVirtualStackMibCompliances 2 } hpSwitchStackConfigGroup OBJECT-GROUP OBJECTS { hpSwitchStackAdminStatus, hpSwitchStackCommandAddr, hpSwitchStackName, hpSwitchStackPropagate, hpSwitchStackAutoJoin, hpSwitchStackAutoGrab, hpSwitchStackMemberSwitchNum, hpSwitchStackMemberMacAddr, hpSwitchStackMemberPassword, hpSwitchStackMemberEntryStatus } STATUS deprecated DESCRIPTION "A collection of objects for configuring a stack." ::= { hpSwitchVirtualStackMibGroups 1 } hpSwitchStackStatsGroup OBJECT-GROUP OBJECTS { hpStackStatsName, hpStackStatsMembersNum, hpStackStatsMembersUnreachable, hpStackStatsMemberID, hpStackStatsMgmtIpAddr, hpStackStatsStackingStatus, hpStackStatsMemberSwitchIndx, hpStackStatsMemberMacAddr, hpStackStatsMemberSystemName, hpStackStatsMemberDeviceType, hpStackStatsMemberOperStatus } STATUS current DESCRIPTION "A collection of objects for determining state and status of a stack." ::= { hpSwitchVirtualStackMibGroups 2 } hpSwitchDiscoverConfigGroup OBJECT-GROUP OBJECTS { hpSwitchDiscoveryAdminStatus, hpSwitchDiscoveryTransmissionInterval } STATUS current DESCRIPTION "A collection of objects for configuring the state of the stack discovery protocol." ::= { hpSwitchVirtualStackMibGroups 3 } hpDiscoverStatsGroup OBJECT-GROUP OBJECTS { hpDiscoverStatsCandidateMacAddr, hpDiscoverStatsCandidateSystemName, hpDiscoverStatsCandidateDeviceType, hpDiscoverStatsSwitchIndex, hpDiscoverStatsSwitchStackName, hpDiscoverStatsSwitchMacAddr, hpDiscoverStatsSwitchSystemName, hpDiscoverStatsSwitchStatus } STATUS current DESCRIPTION "A collection of objects for viewing the discovered devices by the stack discovery protocol." ::= { hpSwitchVirtualStackMibGroups 4 } hpSwitchStackConfigGroup1 OBJECT-GROUP OBJECTS { hpSwitchStackAdminStatus, hpSwitchStackCommandAddr, hpSwitchStackName, hpSwitchStackPropagate, hpSwitchStackAutoJoin, hpSwitchStackAutoGrab, hpSwitchStackMemberSwitchNum, hpSwitchStackMemberMacAddr, hpSwitchStackMemberPasswordLong, hpSwitchStackMemberEntryStatus } STATUS current DESCRIPTION "A collection of objects for configuring a stack." ::= { hpSwitchVirtualStackMibGroups 5 } END