-- ================================================================= -- Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved. -- -- Description: stack mib -- Reference: STACK-MIB -- Version: V1.2 -- History: -- V1.0 created by ranbin -- Initial version 2008-04-30 -- V1.1 Modified by zhengwei -- Change the range of link-delay to 0-30000ms -- V1.2 2013-08-16 updated by wangpengju -- Added a new node hh3cStackPortForwardingPath to hh3cStackPortInfoTable -- 2013-10-23 updated by zhengwei -- Added notification nodes because MAD group work status changed: -- hh3cStackMadBfdChangeNormal -- hh3cStackMadBfdChangeFailure -- hh3cStackMadLacpChangeNormal -- hh3cStackMadLacpChangeFailure -- ================================================================= HH3C-STACK-MIB DEFINITIONS ::= BEGIN IMPORTS hh3cCommon FROM HH3C-OID-MIB entPhysicalIndex FROM ENTITY-MIB ifIndex, ifDescr FROM IF-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; hh3cStack MODULE-IDENTITY LAST-UPDATED "200804301650Z" -- 30th April, 2007 at 16:50 GMT ORGANIZATION "Hangzhou H3C Technologies Co., Ltd." CONTACT-INFO "Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.h3c.com Zip:100085" DESCRIPTION "This MIB is used to manage STM (Stack Topology Management) information for IRF (Intelligent Resilient Framework) device. This MIB is applicable to IRF-capable products. Some objects in this MIB may be used only for some specific products, so users should refer to the related documents to acquire more detailed information." REVISION "200804301650Z" -- 30th April, 2007 at 16:50 GMT DESCRIPTION "The initial revision of this MIB module." ::= { hh3cCommon 91 } -- Scalar MIB objects, which are considered as global variables -- Global Level Configuration hh3cStackGlobalConfig OBJECT IDENTIFIER ::= { hh3cStack 1 } hh3cStackMaxMember OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of members in a stack." ::= { hh3cStackGlobalConfig 1 } hh3cStackMemberNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of members currently in a stack." ::= { hh3cStackGlobalConfig 2 } hh3cStackMaxConfigPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The highest priority that can be configured for a member in a stack." ::= { hh3cStackGlobalConfig 3 } hh3cStackAutoUpdate OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The function for automatically updating the image from the master to a device that is attempting to join the stack. When a new device tries to join a stack, STM verifies the image consistency between the joining device and the master. If the joining device uses a different image version than the master, the function updates the joining device with the image of the master. When this function is disabled, the new device can not join the stack if it uses a different software version than the master. disabled: disable auto update function enabled: enable auto update function" ::= { hh3cStackGlobalConfig 4 } hh3cStackMacPersistence OBJECT-TYPE SYNTAX INTEGER { notPersist(1), persistForSixMin(2), persistForever(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The mode of bridge MAC address persistence. When a stack starts, the bridge MAC address of the master is used as that of the stack. When the master leaves the stack, the bridge MAC address of the stack changes depending on the mode of bridge MAC address persistence. notPersist: The bridge MAC address of the new master is used as that of the stack immediately. persistForSixMin: The original bridge MAC address will be reserved for six minutes. In this period, if the master that has left rejoins the stack, the bridge MAC address of the stack will not change. If the old master does not rejoin the stack within this period, the bridge MAC address of the new master will be used as that of the stack. persistForever: Whether the master leaves or not, the bridge MAC address of the stack will never change." ::= { hh3cStackGlobalConfig 5 } hh3cStackLinkDelayInterval OBJECT-TYPE SYNTAX Integer32 (0..30000) UNITS "millisecond" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay for stack ports to report a link down event. If the link comes up before the delay timer expires, the stack port will not report the link down event. If the link is not recovered before the delay timer expires, the stack port will report the change. If the delay is set to 0, the stack ports will report a link down event without delay. 0: no delay 1-30000(ms): delay time" ::= { hh3cStackGlobalConfig 6 } hh3cStackTopology OBJECT-TYPE SYNTAX INTEGER { chainConn(1), ringConn(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Stack topology. chainConn: daisy-chain connection ringConn: ring connection" ::= { hh3cStackGlobalConfig 7 } -- Device Level Configuration hh3cStackDeviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackDeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage device information in a stack." ::= { hh3cStack 2 } hh3cStackDeviceConfigEntry OBJECT-TYPE SYNTAX Hh3cStackDeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage device information in a stack." INDEX { entPhysicalIndex } ::= { hh3cStackDeviceConfigTable 1 } Hh3cStackDeviceConfigEntry ::= SEQUENCE { hh3cStackMemberID Integer32, hh3cStackConfigMemberID Integer32, hh3cStackPriority Integer32, hh3cStackPortNum Integer32, hh3cStackPortMaxNum Integer32 } hh3cStackMemberID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The member ID of the device in a stack." ::= { hh3cStackDeviceConfigEntry 1 } hh3cStackConfigMemberID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The configured member ID of the device. The valid value ranges from 1 to the value in hh3cStackMaxMember. The configured member ID will take effect at a reboot if it is unique within the stack." ::= { hh3cStackDeviceConfigEntry 2 } hh3cStackPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The priority of a device in the stack. The valid value ranges from 1 to the value in hh3cStackMaxConfigPriority." ::= { hh3cStackDeviceConfigEntry 3 } hh3cStackPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of stack ports enabled in a device." ::= { hh3cStackDeviceConfigEntry 4 } hh3cStackPortMaxNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of stack ports in a device." ::= { hh3cStackDeviceConfigEntry 5 } -- Board Level Configuration hh3cStackBoardConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackBoardConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage MPU information for a stack." ::= { hh3cStack 3 } hh3cStackBoardConfigEntry OBJECT-TYPE SYNTAX Hh3cStackBoardConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage MPU information for a stack." INDEX { entPhysicalIndex } ::= { hh3cStackBoardConfigTable 1 } Hh3cStackBoardConfigEntry ::= SEQUENCE { hh3cStackBoardRole INTEGER, hh3cStackBoardBelongtoMember Integer32 } hh3cStackBoardRole OBJECT-TYPE SYNTAX INTEGER { slave(1), master(2), loading(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The role of the MPU in a stack. slave: Standby MPU master: Master MPU loading: Standby MPU is loading the software image from the master. other: other" ::= { hh3cStackBoardConfigEntry 1 } hh3cStackBoardBelongtoMember OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Member ID of the device that holds the current board." ::= { hh3cStackBoardConfigEntry 2 } -- stack port Information hh3cStackPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage stack port information for IRF stacked devices." ::= { hh3cStack 4 } hh3cStackPortInfoEntry OBJECT-TYPE SYNTAX Hh3cStackPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage stack port information for IRF stacked devices." INDEX { hh3cStackMemberID, hh3cStackPortIndex } ::= { hh3cStackPortInfoTable 1 } Hh3cStackPortInfoEntry ::= SEQUENCE { hh3cStackPortIndex Integer32, hh3cStackPortEnable INTEGER, hh3cStackPortStatus INTEGER, hh3cStackNeighbor Integer32, hh3cStackPortForwardingPath OCTET STRING } hh3cStackPortIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of a stack port of the device." ::= { hh3cStackPortInfoEntry 1 } hh3cStackPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of a stack port of the device. If no physical ports are added to the stack port, its status is 'disabled'. If the stack port has physical ports, its status is 'enabled'. disabled: The stack port is disabled. enabled: The stack port is enabled." ::= { hh3cStackPortInfoEntry 2 } hh3cStackPortStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), silent(3), disabled(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link status of a stack port on the device. up: A physical link is present on the stack port. down: No physical link is present on the stack port. silent: The link state of the stack port is up, but the port cannot transmit or receive traffic. disabled: The stack port does not contain physical links." ::= { hh3cStackPortInfoEntry 3 } hh3cStackNeighbor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The member ID of the stack port's neighbor. 0 means no neighbor exists." ::= { hh3cStackPortInfoEntry 4 } hh3cStackPortForwardingPath OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..511)) MAX-ACCESS read-only STATUS current DESCRIPTION "List of egress member IDs on a stack port. Each member device uses the egress member ID lists to choose the outgoing stack port for known unicast frames to be sent out of other member devices. The egress member ID lists are comma separated. A zero-length string means no egress members exist. For example: In a ring stack of 1-2-3-4-5-7-1, if hh3cStackPortForwardingPath.1.1 returns '7,5,4', IRF-port 1/1 will be the outgoing port for frames to reach members 7, 5, and 4 from member 1." ::= { hh3cStackPortInfoEntry 5 } -- Physical port Information hh3cStackPhyPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackPhyPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage information about physical ports that can be used for IRF stacking." ::= { hh3cStack 5 } hh3cStackPhyPortInfoEntry OBJECT-TYPE SYNTAX Hh3cStackPhyPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage information about physical ports that can be used for IRF stacking." INDEX { entPhysicalIndex } ::= { hh3cStackPhyPortInfoTable 1 } Hh3cStackPhyPortInfoEntry ::= SEQUENCE { hh3cStackBelongtoPort Integer32 } hh3cStackBelongtoPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the stack port to which the physical port is added. 0 means the physical port is not added to any stack port. The value will take effect when IRF is enabled on the device." ::= { hh3cStackPhyPortInfoEntry 1 } -- -- Notification definitions -- -- ================================================================= -- Traps are defined below. hh3cStackTrap OBJECT IDENTIFIER ::= { hh3cStack 6 } -- All objects used for TRAP only are defined here. hh3cStackTrapOjbects OBJECT IDENTIFIER ::= { hh3cStackTrap 0 } hh3cStackPortLinkStatusChange NOTIFICATION-TYPE OBJECTS { hh3cStackMemberID, hh3cStackPortIndex, hh3cStackPortStatus } STATUS current DESCRIPTION "The hh3cStackPortLinkStatusChange trap indicates that the link status of the stack port has changed." ::= { hh3cStackTrapOjbects 1 } hh3cStackTopologyChange NOTIFICATION-TYPE OBJECTS { hh3cStackTopology } STATUS current DESCRIPTION "The hh3cStackTopologyChange trap indicates that the topology type of the IRF stack has changed." ::= { hh3cStackTrapOjbects 2 } hh3cStackMadBfdChangeNormal NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION "The hh3cStackMadBfdChangeNormal trap indicates that the BFD MAD function changed to the normal state." ::= { hh3cStackTrapOjbects 3 } hh3cStackMadBfdChangeFailure NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION "The hh3cStackMadBfdChangeFailure trap indicates that the BFD MAD function changed to the failure state." ::= { hh3cStackTrapOjbects 4 } hh3cStackMadLacpChangeNormal NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION "The hh3cStackMadLacpChangeNormal trap indicates that the LACP MAD function changed to the normal state." ::= { hh3cStackTrapOjbects 5 } hh3cStackMadLacpChangeFailure NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION "The hh3cStackMadLacpChangeFailure trap indicates that the LACP MAD function changed to the failure state." ::= { hh3cStackTrapOjbects 6 } END