-- ================================================================== -- Copyright (C) 2005 by HUAWEI-3COM TECHNOLOGIES. All rights reserved. -- -- Description: H3C MPLSOAM PS(protection switching) MIB -- Reference: -- Version: V1.0 -- History: -- V1.0 2007-03-31 Created by LiXufu ID: 05023 -- ================================================================== H3C-MPLSOAM-PS-MIB DEFINITIONS ::= BEGIN IMPORTS h3cCommon FROM HUAWEI-3COM-OID-MIB Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI TruthValue, RowStatus FROM SNMPv2-TC; h3cMplsOamPs MODULE-IDENTITY LAST-UPDATED "200703310000Z" -- March 31, 2007 at 00:00 GMT ORGANIZATION "Huawei 3Com Technologies Co., Ltd." CONTACT-INFO "Platform Team Huawei 3Com Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.huawei-3com.com Zip:100085" DESCRIPTION "This MIB contains objects to configure mpls protect-switch module." ::= { h3cCommon 80 } -- ================================================================== -- -- ======================= definition begin ========================= -- -- ================================================================== h3cMplsOamPsScalarGroup OBJECT IDENTIFIER ::= { h3cMplsOamPs 1 } h3cMplsOamPsTrapOpen OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Whether mpls protect-switch trap is globally enabled. false: disable; true: enable" DEFVAL { false } ::= { h3cMplsOamPsScalarGroup 1 } h3cMplsOamPsTable OBJECT IDENTIFIER ::= { h3cMplsOamPs 2 } h3cMplsPsTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cMplsPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies per-protection-group MPLS PS capability and associated information." ::= { h3cMplsOamPsTable 1 } h3cMplsPsEntry OBJECT-TYPE SYNTAX H3cMplsPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by an LSR for every protection group capable of supporting mpls ps." INDEX { h3cMplsPsIndex } ::= { h3cMplsPsTable 1 } H3cMplsPsEntry ::= SEQUENCE { h3cMplsPsIndex Integer32, h3cMplsPsGroupID Integer32, h3cMplsPsWorkLspName OCTET STRING, h3cMplsPsProtectLspName OCTET STRING, h3cMplsPsRevertiveMode Integer32, h3cMplsPsWTR Integer32, h3cMplsPsHoldOff Integer32, h3cMplsPsSwitchCondition Integer32, h3cMplsPsWorkLspDetectState Integer32, h3cMplsPsWorkLspUpDownState Integer32, h3cMplsPsProtLspDetectState Integer32, h3cMplsPsProtLspUpDownState Integer32, h3cMplsPsSwitchResult Integer32, h3cMplsPsRowStatus RowStatus } h3cMplsPsIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the mplspsEntry." ::= { h3cMplsPsEntry 1 } h3cMplsPsGroupID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a unique group id for an entry in the mplspsEntry. One protect-switch group is composed of one working static-lsp and one protection static-lsp." ::= { h3cMplsPsEntry 2 } h3cMplsPsWorkLspName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the working static-lsp." ::= { h3cMplsPsEntry 3 } h3cMplsPsProtectLspName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the protection static-lsp." ::= { h3cMplsPsEntry 4 } h3cMplsPsRevertiveMode OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-create STATUS current DESCRIPTION "Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired. And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;" ::= { h3cMplsPsEntry 5 } h3cMplsPsWTR OBJECT-TYPE SYNTAX Integer32 UNITS "30s" MAX-ACCESS read-create STATUS current DESCRIPTION "Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP, it prevents reversion back to select the working LSP until the Wait to Restore timer has expired. The default value is 12 minutes. step is 30s." ::= { h3cMplsPsEntry 6 } h3cMplsPsHoldOff OBJECT-TYPE SYNTAX Integer32 UNITS "100ms" MAX-ACCESS read-create STATUS current DESCRIPTION "The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. Step is 100ms, maximum is 10s." ::= { h3cMplsPsEntry 7 } h3cMplsPsSwitchCondition OBJECT-TYPE SYNTAX Integer32(1..9) MAX-ACCESS read-create STATUS current DESCRIPTION "The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp" ::= { h3cMplsPsEntry 8 } h3cMplsPsWorkLspDetectState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of working static-lsp state in one protection group, whether it is in defect: 1: it is out of defect; 2: it enters defect." ::= { h3cMplsPsEntry 9 } h3cMplsPsWorkLspUpDownState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of working static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state." ::= { h3cMplsPsEntry 10 } h3cMplsPsProtLspDetectState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of protection static-lsp state in one protection group, whether it is in detection: 1: it is out of defect; 2: it enters defect." ::= { h3cMplsPsEntry 11 } h3cMplsPsProtLspUpDownState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of protection static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state." ::= { h3cMplsPsEntry 12 } h3cMplsPsSwitchResult OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Which tunnel is used to transfer the data stream. 1: working static-lsp; 2: protection static-lsp." ::= { h3cMplsPsEntry 13 } h3cMplsPsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation. To create a new row, h3cMplsPsGroupID, h3cMplsPsWorkLspName, h3cMplsPsProtectLspName, h3cMplsPsRevertiveMode, h3cMplsPsWTR and h3cMplsPsHoldOff must be specified." ::= { h3cMplsPsEntry 14 } h3cMplsOamPsNotifications OBJECT IDENTIFIER ::= { h3cMplsOamPs 3 } h3cMplsPsSwitchPtoW NOTIFICATION-TYPE OBJECTS { h3cMplsPsWorkLspName, h3cMplsPsProtectLspName, h3cMplsPsSwitchResult } STATUS current DESCRIPTION "This notification is generated when switching from protection-lsp to working-lsp occured." ::= { h3cMplsOamPsNotifications 1 } h3cMplsPsSwitchWtoP NOTIFICATION-TYPE OBJECTS { h3cMplsPsWorkLspName, h3cMplsPsProtectLspName, h3cMplsPsSwitchResult } STATUS current DESCRIPTION "This notification is generated when switching from woking-lsp to protection-lsp occured." ::= { h3cMplsOamPsNotifications 2 } END