-- Version 2.15.1.1, modified 2001-05-31 17:27:54-04 FRDCE-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500PCTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 3 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual conventions Counter16 ::= INTEGER (0..65535) DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) PhysAddress ::= OCTET STRING -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. -- The Frame Relay DCE Port Configuration Table -- This table contains Configuration paramaters -- for the Frame Relay DCE Port table. cdx6500PCTFRDCEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PCTFRDCEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Frame Relay DCE Port table." ::= { cdx6500PCTPortProtocolGroup 6 } cdx6500PCTFRDCEPortEntry OBJECT-TYPE SYNTAX Cdx6500PCTFRDCEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of SDLC Port configuration parameters." INDEX { cdx6500frdcepCfgPortNum } ::= { cdx6500PCTFRDCEPortTable 1 } Cdx6500PCTFRDCEPortEntry ::= SEQUENCE { cdx6500frdcepCfgPortNum INTEGER, cdx6500frdcepConnectionType INTEGER, cdx6500frdcepClockSource INTEGER, cdx6500frdcepClockSpeed INTEGER, cdx6500frdcepMaxStations INTEGER, cdx6500frdcepCtrlProtocol INTEGER, cdx6500frdcepT391 INTEGER, cdx6500frdcepT392 INTEGER, cdx6500frdcepN391 INTEGER, cdx6500frdcepN392 INTEGER, cdx6500frdcepN393 INTEGER, cdx6500frdcepNT1 INTEGER, cdx6500frdcepNT2 INTEGER, cdx6500frdcepNN1 INTEGER, cdx6500frdcepNN2 INTEGER, cdx6500frdcepNN3 INTEGER, cdx6500frdcepSubaddress DisplayString, cdx6500frdcepBiDirAnnexD INTEGER, cdx6500frdcepInvertTXClock INTEGER, cdx6500frdcepControlProtocolOptions DisplayString, cdx6500frdcepDiscardControlOptions INTEGER, cdx6500frdcepElectricalInterfaceType INTEGER, cdx6500frdcepV24ElectricalInterfaceOption INTEGER, cdx6500frdcepHighSpeedElectricalInterfaceOption INTEGER } cdx6500frdcepCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port Number." ::= { cdx6500PCTFRDCEPortEntry 1 } cdx6500frdcepConnectionType OBJECT-TYPE SYNTAX INTEGER { simp (0), newvalSimp (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. newvalSimp - same functionality as 'simp', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTFRDCEPortEntry 2 } cdx6500frdcepClockSource OBJECT-TYPE SYNTAX INTEGER { int (0), ext (1), extint (2), extlp (3), newvalInt (50) } ACCESS read-only STATUS mandatory DESCRIPTION "int - internal clock source. ext - external clock source. extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTFRDCEPortEntry 3 } cdx6500frdcepClockSpeed OBJECT-TYPE SYNTAX INTEGER (1200..2048000) ACCESS read-only STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second, when using internal clocking. Note that the maximum port speed is dependent on the type of hardware installed. Consult the users manual for details." ::= { cdx6500PCTFRDCEPortEntry 4 } cdx6500frdcepMaxStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "The highest station number to be configured on this FRA port. It is used to limit the configuration of stations." ::= { cdx6500PCTFRDCEPortEntry 5 } cdx6500frdcepCtrlProtocol OBJECT-TYPE SYNTAX INTEGER { annexD (0), none (1), lmi (2), annexA (3), newvalAnnexD (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. newvalAnnexD - same functionality as 'annexD', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTFRDCEPortEntry 6 } cdx6500frdcepT391 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds." ::= { cdx6500PCTFRDCEPortEntry 7 } cdx6500frdcepT392 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1." ::= { cdx6500PCTFRDCEPortEntry 8 } cdx6500frdcepN391 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls." ::= { cdx6500PCTFRDCEPortEntry 9 } cdx6500frdcepN392 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3." ::= { cdx6500PCTFRDCEPortEntry 10 } cdx6500frdcepN393 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2." ::= { cdx6500PCTFRDCEPortEntry 11 } cdx6500frdcepNT1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds." ::= { cdx6500PCTFRDCEPortEntry 12 } cdx6500frdcepNT2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1." ::= { cdx6500PCTFRDCEPortEntry 13 } cdx6500frdcepNN1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls." ::= { cdx6500PCTFRDCEPortEntry 14 } cdx6500frdcepNN2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3." ::= { cdx6500PCTFRDCEPortEntry 15 } cdx6500frdcepNN3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2." ::= { cdx6500PCTFRDCEPortEntry 16 } cdx6500frdcepSubaddress OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) ACCESS read-only STATUS mandatory DESCRIPTION "Calls addressed to this node and with this subaddress will be routed to this port." ::= { cdx6500PCTFRDCEPortEntry 17 } cdx6500frdcepBiDirAnnexD OBJECT-TYPE SYNTAX INTEGER { bi (0), uni (1), newvalBi (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Whether ANSI T1.617 Annex D bi-directional procedures are enabled bi - Bi-directional procedures are enabled. uni - Uni-directional procedures are enabled. newvalBi - same functionality as 'bi', new enumeration added for RFC1155 compatibility." ::= { cdx6500PCTFRDCEPortEntry 18 } cdx6500frdcepInvertTXClock OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert." -- DEFVAL { no } ::= { cdx6500PCTFRDCEPortEntry 19 } cdx6500frdcepControlProtocolOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) ACCESS read-only STATUS mandatory DESCRIPTION "These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)" ::= { cdx6500PCTFRDCEPortEntry 20 } cdx6500frdcepDiscardControlOptions OBJECT-TYPE SYNTAX INTEGER { none (1), debit (2) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames" -- DEFVAL { none } ::= { cdx6500PCTFRDCEPortEntry 21 } cdx6500frdcepElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PCTFRDCEPortEntry 22 } cdx6500frdcepV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PCTFRDCEPortEntry 23 } cdx6500frdcepHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PCTFRDCEPortEntry 24 } -- The Frame Relay DCE Port Statistics Table -- This table contains Statistics paramaters -- for the Frame Relay DCE Port table. cdx6500PPSTFRDCEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRDCEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Frame Relay DCE Port table." ::= { cdx6500PSTPortProtocolGroup 6 } cdx6500PPSTFRDCEPortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRDCEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Relay DCE Port statistics parameters." INDEX { cdx6500frdcepStatsPortNum } ::= { cdx6500PPSTFRDCEPortTable 1 } Cdx6500PPSTFRDCEPortEntry ::= SEQUENCE { cdx6500frdcepStatsPortNum INTEGER, cdx6500frdcepPortStatus INTEGER, cdx6500frdcepPortSpeed INTEGER, cdx6500frdcepUtilizationIn INTEGER, cdx6500frdcepUtilizationOut INTEGER, cdx6500frdcepCharInTotal Counter, cdx6500frdcepCharOutTotal Counter, cdx6500frdcepCharsInPerSec INTEGER, cdx6500frdcepCharsOutPerSec INTEGER, cdx6500frdcepFrameInTotal Counter, cdx6500frdcepFrameOutTotal Counter, cdx6500frdcepFramesInPerSec INTEGER, cdx6500frdcepFramesOutPerSec INTEGER, cdx6500frdcepOverrunErrors Counter16, cdx6500frdcepUnderrunErrors Counter16, cdx6500frdcepCRCErrors Counter16 } cdx6500frdcepStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port Number." ::= { cdx6500PPSTFRDCEPortEntry 1 } cdx6500frdcepPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), busyOut (2), up (3), down (4), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "Port Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - Port is down. disabled - Port has been disabled. enabled - port has been enabled, but is not yet Up. busyOut - port has been set to be disabled as soon as last active call is disestablished. No new calls will be established. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility." ::= { cdx6500PPSTFRDCEPortEntry 2 } cdx6500frdcepPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device." ::= { cdx6500PPSTFRDCEPortEntry 3 } cdx6500frdcepUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Pertcentage of Port input bandwidth in use." ::= { cdx6500PPSTFRDCEPortEntry 4 } cdx6500frdcepUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Pertcentage of Port output bandwidth in use." ::= { cdx6500PPSTFRDCEPortEntry 5 } cdx6500frdcepCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of message received since last node, port, or statistics reset." ::= { cdx6500PPSTFRDCEPortEntry 6 } cdx6500frdcepCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of message sent since last node, port, or statistics reset." ::= { cdx6500PPSTFRDCEPortEntry 7 } cdx6500frdcepCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received per second." ::= { cdx6500PPSTFRDCEPortEntry 8 } cdx6500frdcepCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received per second." ::= { cdx6500PPSTFRDCEPortEntry 9 } cdx6500frdcepFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node, port, or statistics reset." ::= { cdx6500PPSTFRDCEPortEntry 10 } cdx6500frdcepFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames sent since last node, port, or statistics reset." ::= { cdx6500PPSTFRDCEPortEntry 11 } cdx6500frdcepFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second during the previous minute" ::= { cdx6500PPSTFRDCEPortEntry 12 } cdx6500frdcepFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second during the previous minute" ::= { cdx6500PPSTFRDCEPortEntry 13 } cdx6500frdcepOverrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of overrun errors counted by the I/O driver." ::= { cdx6500PPSTFRDCEPortEntry 14 } cdx6500frdcepUnderrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of underrun errors counted by the I/O driver." ::= { cdx6500PPSTFRDCEPortEntry 15 } cdx6500frdcepCRCErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Total number of CRC errors counted by the I/O driver." ::= { cdx6500PPSTFRDCEPortEntry 16 } -- The Frame Relay DCE Station Configuration Table -- This table contains Configuration paramaters -- for the Frame Relay DCE Station table. cdx6500SPCTFRDCEStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPCTFRDCEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Frame Relay DCE Station table." ::= { cdx6500PCTStationProtocolGroup 3 } cdx6500SPCTFRDCEStationEntry OBJECT-TYPE SYNTAX Cdx6500SPCTFRDCEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Relay DCE station configuration parameters." INDEX { cdx6500frdcesCfgPortNum, cdx6500frdcesCfgDLCI } ::= { cdx6500SPCTFRDCEStationTable 1 } Cdx6500SPCTFRDCEStationEntry ::= SEQUENCE { cdx6500frdcesCfgPortNum INTEGER, cdx6500frdcesCfgDLCI INTEGER, cdx6500frdcesAutocallMnem DisplayString, cdx6500frdcesAutocallTimeout INTEGER, cdx6500frdcesMaxAutocalls INTEGER, cdx6500frdcesRemoteConnID INTEGER, cdx6500frdcesPriority INTEGER, cdx6500frdcesBillingRecords INTEGER, cdx6500frdcesStationNum INTEGER, cdx6500frdcesMaxInboundQueue INTEGER } cdx6500frdcesCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Station number." ::= { cdx6500SPCTFRDCEStationEntry 1 } cdx6500frdcesCfgDLCI OBJECT-TYPE SYNTAX INTEGER (16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port. Its valid range is 16 - 1007. It must match the DLCI configured on the attached FRAD." ::= { cdx6500SPCTFRDCEStationEntry 2 } cdx6500frdcesAutocallMnem OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "This is the mnemonic name used for auto calling. A blank indicates auto calling is disabled." ::= { cdx6500SPCTFRDCEStationEntry 3 } cdx6500frdcesAutocallTimeout OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This is the time interval in seconds between call attempts when auto calling." ::= { cdx6500SPCTFRDCEStationEntry 4 } cdx6500frdcesMaxAutocalls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is used to specify the number of times that this FRA station will attempt to call when auto calling is enabled. A value of zero will allow unlimited attempts." ::= { cdx6500SPCTFRDCEStationEntry 5 } cdx6500frdcesRemoteConnID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the number of the remote LAN Connection or the number of the remote FRA station that this FRA station will attempt to connect to if configured for autocall." ::= { cdx6500SPCTFRDCEStationEntry 6 } cdx6500frdcesPriority OBJECT-TYPE SYNTAX INTEGER { low (0), medium (1), high (2), expedite (3), newvalLow (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This parameter specifies the Traffic Priority of this FRA station. newvalLow - same functionality as 'low', new enumeration added for RFC1155 compatibility." ::= { cdx6500SPCTFRDCEStationEntry 7 } cdx6500frdcesBillingRecords OBJECT-TYPE SYNTAX INTEGER { disabled (0), enabled (1), newvalDisabled (50) } ACCESS read-only STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this FRA station. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compliance." ::= { cdx6500SPCTFRDCEStationEntry 8 } cdx6500frdcesStationNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of the logical link on the line. This is the value of Sxx for routing purposes." ::= { cdx6500SPCTFRDCEStationEntry 9 } cdx6500frdcesMaxInboundQueue OBJECT-TYPE SYNTAX INTEGER (100..2500) ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the maximum number of frames which may be queued in the station's inbound queue. A smaller value may be choosen for applications which experience objectionable delays, if due to excessive growth of the station's inbound queue." -- DEFVAL { 2500 } ::= { cdx6500SPCTFRDCEStationEntry 10 } -- The Frame Relay DCE Station Statistics Table -- This table contains Statistics paramaters -- for the Frame Relay DCE Station table. cdx6500SPSTFRDCEStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPSTFRDCEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Frame Relay DCE Station (DLCI) table." ::= { cdx6500PSTStationProtocolGroup 3 } cdx6500SPSTFRDCEStationEntry OBJECT-TYPE SYNTAX Cdx6500SPSTFRDCEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Relay DCE station (DLCI) Statistics parameters." INDEX { cdx6500frdcesStatsPortNum, cdx6500frdcesStatsDLCI } ::= { cdx6500SPSTFRDCEStationTable 1 } Cdx6500SPSTFRDCEStationEntry ::= SEQUENCE { cdx6500frdcesStatsPortNum INTEGER, cdx6500frdcesStatsDLCI INTEGER, cdx6500frdcesUtilizationIn INTEGER, cdx6500frdcesUtilizationOut INTEGER, cdx6500frdcesMaxSVCCount INTEGER, cdx6500frdcesCurrentSVCCount INTEGER, cdx6500frdcesCharInTotal Counter, cdx6500frdcesCharOutTotal Counter, cdx6500frdcesCharsInPerSec INTEGER, cdx6500frdcesCharsOutPerSec INTEGER, cdx6500frdcesPktInTotal Counter, cdx6500frdcesPktOutTotal Counter, cdx6500frdcesPktsInPerSec INTEGER, cdx6500frdcesPktsOutPerSec INTEGER, cdx6500frdcesPacketsQueued INTEGER, cdx6500frdcesFrameInTotal Counter, cdx6500frdcesFrameOutTotal Counter, cdx6500frdcesFramesInPerSec INTEGER, cdx6500frdcesFramesOutPerSec INTEGER, cdx6500frdcesInfoFramesIn Counter, cdx6500frdcesInfoFramesOut Counter, cdx6500frdcesRNRFramesIn Counter, cdx6500frdcesRNRFramesOut Counter, cdx6500frdcesRRFramesIn Counter, cdx6500frdcesRRFramesOut Counter, cdx6500frdcesREJFramesIn Counter, cdx6500frdcesREJFramesOut Counter, cdx6500frdcesDataPktsIn Counter, cdx6500frdcesDataPktsOut Counter, cdx6500frdcesResetStats INTEGER, cdx6500frdcesBoot INTEGER, cdx6500frdcesDisable INTEGER, cdx6500frdcesEnable INTEGER } cdx6500frdcesStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..54) ACCESS read-only STATUS mandatory DESCRIPTION "Port Number." ::= { cdx6500SPSTFRDCEStationEntry 1 } cdx6500frdcesStatsDLCI OBJECT-TYPE SYNTAX INTEGER (16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port." ::= { cdx6500SPSTFRDCEStationEntry 2 } cdx6500frdcesUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The quantity of user bytes received on the line as a percentage of the maximum number of bytes that could have been received." ::= { cdx6500SPSTFRDCEStationEntry 3 } cdx6500frdcesUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "The quantity of user bytes sent on the line as a percentage of the maximum number of bytes that could have been received." ::= { cdx6500SPSTFRDCEStationEntry 4 } cdx6500frdcesMaxSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Maximum number of SVCs available in the network." ::= { cdx6500SPSTFRDCEStationEntry 5 } cdx6500frdcesCurrentSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Number of SVCs currently in use." ::= { cdx6500SPSTFRDCEStationEntry 6 } cdx6500frdcesCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 7 } cdx6500frdcesCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of characters sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 8 } cdx6500frdcesCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500SPSTFRDCEStationEntry 9 } cdx6500frdcesCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters transmitted per second." ::= { cdx6500SPSTFRDCEStationEntry 10 } cdx6500frdcesPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of Packets received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 11 } cdx6500frdcesPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of Packets sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 12 } cdx6500frdcesPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of Packets received per second." ::= { cdx6500SPSTFRDCEStationEntry 13 } cdx6500frdcesPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of Packets transmitted per second." ::= { cdx6500SPSTFRDCEStationEntry 14 } cdx6500frdcesPacketsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of packets buffered since since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 15 } cdx6500frdcesFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 16 } cdx6500frdcesFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of frames sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 17 } cdx6500frdcesFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500SPSTFRDCEStationEntry 18 } cdx6500frdcesFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second." ::= { cdx6500SPSTFRDCEStationEntry 19 } cdx6500frdcesInfoFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of data frames received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 20 } cdx6500frdcesInfoFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of data frames sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 21 } cdx6500frdcesRNRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of RNR frames received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 22 } cdx6500frdcesRNRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of RNR frames sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 23 } cdx6500frdcesRRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of RR frames received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 24 } cdx6500frdcesRRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of RR frames sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 25 } cdx6500frdcesREJFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of REJ frames received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 26 } cdx6500frdcesREJFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS deprecated DESCRIPTION "Number of REJ frames sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 27 } cdx6500frdcesDataPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of data packets received since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 28 } cdx6500frdcesDataPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of data packets sent since last node, port, or station boot or statistics reset." ::= { cdx6500SPSTFRDCEStationEntry 29 } -- The Frame Relay DCE Station Control objects -- These objects provide Control parameters -- for the Frame Relay DCE Stations. cdx6500frdcesResetStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS obsolete DESCRIPTION "reset : Resets the specified Frame Relay station statistics. noReset : Do not reset the specified Frame Relay station statistics." ::= { cdx6500SPSTFRDCEStationEntry 30 } cdx6500frdcesBoot OBJECT-TYPE SYNTAX INTEGER { boot (1), noBoot (2) } ACCESS write-only STATUS obsolete DESCRIPTION "boot : Boots the specified Frame Relay station. noBoot : Do not boot the specified Frame Relay station." ::= { cdx6500SPSTFRDCEStationEntry 31 } cdx6500frdcesDisable OBJECT-TYPE SYNTAX INTEGER { disable (1), noDisable (2) } ACCESS write-only STATUS obsolete DESCRIPTION "disable : Disables the specified Frame Relay station. noDisable : Do not disable the specified Frame Relay station." ::= { cdx6500SPSTFRDCEStationEntry 32 } cdx6500frdcesEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), noEnable (2) } ACCESS write-only STATUS obsolete DESCRIPTION "enable : Enable the specified Frame Relay station. noEnable : Do not enable the specified Frame Relay station." ::= { cdx6500SPSTFRDCEStationEntry 33 } -- The FRA Port Control Table cdx6500ContFRATable OBJECT IDENTIFIER ::= { cdx6500Controls 17 } cdx6500frdcepPContTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500frdcepPContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Control parameters for FRA ports." ::= { cdx6500ContFRATable 1 } cdx6500frdcepPContEntry OBJECT-TYPE SYNTAX Cdx6500frdcepPContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of FRA port control." INDEX { cdx6500frdcepContPortNumber } ::= { cdx6500frdcepPContTable 1 } Cdx6500frdcepPContEntry ::= SEQUENCE { cdx6500frdcepContPortNumber INTEGER, cdx6500frdcepContPortControl INTEGER } cdx6500frdcepContPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "Port number of the FRA port." ::= { cdx6500frdcepPContEntry 1 } cdx6500frdcepContPortControl OBJECT-TYPE SYNTAX INTEGER { boot (1), enable (2), disable (3), resetstats (4) } ACCESS write-only STATUS mandatory DESCRIPTION "Control operations for the specified FRA port. boot - Boots the FRA port enable - Enables the FRA port disable - Disables the FRA port resetstats - Resets the FRA port statistics." ::= { cdx6500frdcepPContEntry 2 } cdx6500frdcesSContTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500frdcesSContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Control parameter for Fra stations" ::= { cdx6500ContFRATable 2 } cdx6500frdcesSContEntry OBJECT-TYPE SYNTAX Cdx6500frdcesSContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of FRA Station control" INDEX { cdx6500frdcesStationPortNumber, cdx6500frdcesStationDLCI } ::= { cdx6500frdcesSContTable 1 } Cdx6500frdcesSContEntry ::= SEQUENCE { cdx6500frdcesStationPortNumber INTEGER, cdx6500frdcesStationDLCI INTEGER, cdx6500frdcesStationControl INTEGER } cdx6500frdcesStationPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "Fra Station Port number" ::= { cdx6500frdcesSContEntry 1 } cdx6500frdcesStationDLCI OBJECT-TYPE SYNTAX INTEGER (16..1007) ACCESS not-accessible STATUS mandatory DESCRIPTION "Fra Station DLCI number" ::= { cdx6500frdcesSContEntry 2 } cdx6500frdcesStationControl OBJECT-TYPE SYNTAX INTEGER { boot (1), enable (2), disable (3), resetstats (4) } ACCESS write-only STATUS mandatory DESCRIPTION "Control operations for the specified FRA station. boot - Boot the FRA station enable - Enables the FRA station disable - Disables the FRA station resetstats - Resets the FRA station statistics." ::= { cdx6500frdcesSContEntry 3 } END