CXPCM-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 cxPCM,SapIndex FROM CXProduct-SMI; -- Propietary Data Types ChannelIndex ::= INTEGER (1..31) -- Pulse Coded Modulation Configuration Table -- The table describes: -- status available for monitoring the current state of the service -- access point. -- statistics available for monitoring any service access point. -- This Service Access Point is considered the PCM access point -- to the voice application. Hence, this MIB is only used in -- voice applications. pcmSapTable OBJECT-TYPE SYNTAX SEQUENCE OF PcmSapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing configuration, controls, status and statistics information about each PCM module layer service access point." ::= { cxPCM 40 } pcmSapEntry OBJECT-TYPE SYNTAX PcmSapEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a specific service access point." INDEX { pcmSapLinkNumber, pcmSapChannelNumber } ::= { pcmSapTable 1 } PcmSapEntry ::= SEQUENCE { -- Parameters pcmSapLinkNumber SapIndex, pcmSapChannelNumber ChannelIndex, -- Status pcmSapChannelState INTEGER, -- Statistics pcmSapRxPacket Counter, pcmSapTxPacket Counter, pcmSapTxDesync Counter, pcmSapTxNotReady Counter, pcmSapRxBusy Counter, pcmSapTxUnderrun Counter } pcmSapLinkNumber OBJECT-TYPE SYNTAX SapIndex ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the link number associated with this SAP. Range of Values: 1-2 for DI600 (port) Default Value: none" ::= { pcmSapEntry 1 } pcmSapChannelNumber OBJECT-TYPE SYNTAX ChannelIndex ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the B channel associated with this SAP. Range of Values: 1-24 for T1 1-31 for E1 Default Value: none" ::= { pcmSapEntry 2 } pcmSapChannelState OBJECT-TYPE SYNTAX INTEGER { down (1), up (2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current state of a voice configured B channel associated to this SAP. Options: down (1): A voice call is not established on this B channel. unbound (2): A voice call is established on this B channel. Default Value: none" ::= { pcmSapEntry 40 } pcmSapRxPacket OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of error-free PCM voice packets received by the link since statistics were last reset. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 60 } pcmSapTxPacket OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the total number of PCM voice packets successfully transmitted by the link since statistics were last reset. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 61 } pcmSapTxDesync OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of silence PCM voice packets sent when the voice application has no packet to send. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 62 } pcmSapTxNotReady OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of reinitialization of this B channel due to a transmitter malfunction. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 63 } pcmSapRxBusy OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of times that the receiver FIFO has been full. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 64 } pcmSapTxUnderrun OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the number of times that the transmitter FIFO has been full. Range of Values: 0-4, 294, 967, 295 Default Value: none" ::= { pcmSapEntry 65 } -- Pulse Coded Modulation Debugging Table -- The table describes: -- controls available to manipulate a service access point -- statistics. -- The Service Access Points here is considered as the access -- point of the voice application. Hence, this MIB is only used -- in voice applications. pcmDebugTable OBJECT-TYPE SYNTAX SEQUENCE OF PcmDebugEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table containing controls about each PCM module layer service access point." ::= { cxPCM 60 } pcmDebugEntry OBJECT-TYPE SYNTAX PcmDebugEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a specific service access point." INDEX { pcmDebugLinkNumber } ::= { pcmDebugTable 1 } PcmDebugEntry ::= SEQUENCE { -- Parameters pcmDebugLinkNumber SapIndex, -- Controls pcmDebugLoopInfo INTEGER } pcmDebugLinkNumber OBJECT-TYPE SYNTAX SapIndex ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the link number associated with this SAP. Range of Values: 1-2 for DI600 (port) Default Value: none" ::= { pcmDebugEntry 1 } pcmDebugLoopInfo OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "This object displays the statistics relative to this PCM control block. When pcmSapDebugInfo is set to 1, it does nothing, 2 displays the link information concerning the looping informations and timings while 3 clears these statistics." ::= { pcmDebugEntry 80 } END