-- -- This SMIv2 module has been generated by smidump 0.4.1. Do not edit. -- BRWAVE-RADIO-MIB DEFINITIONS ::= BEGIN IMPORTS ifIndex FROM IF-MIB OBJECT-GROUP FROM SNMPv2-CONF Integer32, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, Unsigned32, enterprises FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC; brwaveRadioMibModule MODULE-IDENTITY LAST-UPDATED "200607061100Z" ORGANIZATION "BridgeWave Communications" CONTACT-INFO " Postal: BridgeWave Communications 3350 Thomas Road Santa Clara, CA 95054 USA Tel: +1 408 567 6900 Fax: +1 408 567 0775 Web: www.bridgewave.com " DESCRIPTION "Radio MIB module." REVISION "200607061100Z" DESCRIPTION "Combined ROOT/RADIO mib in one module." REVISION "200505261130Z" DESCRIPTION "Radio MIB module created." ::= { brwaveMibs 3 } bridgeWave OBJECT-IDENTITY STATUS current DESCRIPTION "BridgeWave enterprise OID." ::= { enterprises 6080 } brwaveReg OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-tree for BridgeWave objects registration." ::= { bridgeWave 1 } brwaveMibs OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-tree to register values assigned to MIB modules with the MODULES-IDENTITY construct." ::= { brwaveReg 1 } brwaveModules OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-tree to register unique values assigned to identify all BridgeWave hardware and software components of ethernet radio products." ::= { brwaveReg 2 } brwaveRadioFE60 OBJECT-IDENTITY STATUS current DESCRIPTION "Registered System OID for FE60 radio." ::= { brwaveModules 1 } brwaveRadioGE60 OBJECT-IDENTITY STATUS current DESCRIPTION "Registered System OID for GE60 radio." ::= { brwaveModules 2 } brwaveRadioAR60 OBJECT-IDENTITY STATUS current DESCRIPTION "Registered system OID for AdaptiveRate(AR60) radio." ::= { brwaveModules 3 } brwaveCommon OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-tree for BridgeWave objects common across products." ::= { bridgeWave 2 } brwaveRadioSn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Radio serial number." ::= { brwaveCommon 1 } brwaveUnitModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit's model." ::= { brwaveCommon 2 } brwaveBbSn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Base Band hardware serial number" ::= { brwaveCommon 3 } brwaveIfSn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IF hardware serial number" ::= { brwaveCommon 4 } brwaveMmwSn OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "MMW Hardware serial number" ::= { brwaveCommon 5 } brwaveTrapCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of traps generated by unit since start-up. Rolls back to zero once reached to maximum value." ::= { brwaveCommon 6 } brwaveProducts OBJECT-IDENTITY STATUS current DESCRIPTION "Sub-tree for product specific objects & events" ::= { bridgeWave 3 } brwaveRadio OBJECT-IDENTITY STATUS current DESCRIPTION "Ethernet Radio (FE60/GE60/AR60) obejcts." ::= { brwaveProducts 1 } brwaveRadioFactorySetup OBJECT-IDENTITY STATUS current DESCRIPTION "Group of factory setup objects." ::= { brwaveRadio 2 } brwaveRadioTxBand OBJECT-TYPE SYNTAX INTEGER { low(1), high(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Radio Link Transmit frequency." ::= { brwaveRadioFactorySetup 1 } brwaveRadioFactoryRate OBJECT-TYPE SYNTAX INTEGER { adaptRate(1), mbps1000(2), mbps100(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Factory configured radio link rate." ::= { brwaveRadioFactorySetup 3 } brwaveRadioClearStats OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Clear Statistics, Set value of 1 to clear. Returns always 0 when read." ::= { brwaveRadioFactorySetup 4 } brwaveRadioStatus OBJECT-IDENTITY STATUS current DESCRIPTION "Group of radio status objects." ::= { brwaveRadio 3 } brwaveRadioInVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage. The reading of the unit's input voltage level in Volts x100." ::= { brwaveRadioStatus 1 } brwaveRadioUnitTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unit Temperature. The reading of the temperature sensor in degrees C x 100." ::= { brwaveRadioStatus 2 } brwaveRadioTxTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Radio Transmiter Temperature. The reading of the radio temperature sensor in degrees C x 100." ::= { brwaveRadioStatus 3 } brwaveRadioRSL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Received Signal Level. The signal level of the received radio frequency in dBm x 100" ::= { brwaveRadioStatus 4 } brwaveRadioRSLVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Received Signal Level measured as Voltage." ::= { brwaveRadioStatus 5 } brwaveRadioAbsRSL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Received Signal Level. The signal level of the received radio frequency in dBm x 100" ::= { brwaveRadioStatus 6 } brwaveRadioRSLVoltageInt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Received Signal Level measured as Voltage." ::= { brwaveRadioStatus 7 } brwaveCopperUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Link utilization calculated every polling interval." ::= { brwaveRadioStatus 8 } brwaveFiberUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Link utilization calculated every polling interval." ::= { brwaveRadioStatus 9 } brwaveRadioUtilization OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Link utilization calculated every polling interval." ::= { brwaveRadioStatus 10 } brwaveRadioFecError OBJECT-TYPE SYNTAX INTEGER { noError(0), preFec(1), postFec(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Post and Pre FEC error calculated every polling interval 0 - No Error, 1-Pre FEC Error, 2-Post FEC Error" ::= { brwaveRadioStatus 11 } brwaveRadioPreFecFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Pre FEC error flag every polling interval" ::= { brwaveRadioStatus 12 } brwaveRadioPostFecFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Post FEC error Flag every polling interval" ::= { brwaveRadioStatus 13 } brwaveRadioLinkRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Radio Link Rate in Mbps." ::= { brwaveRadioStatus 14 } brwaveRadioEvents OBJECT IDENTIFIER ::= { brwaveRadio 9 } brwaveRadioEventsV2 OBJECT IDENTIFIER ::= { brwaveRadioEvents 0 } brwaveRadioTrapObjs OBJECT IDENTIFIER ::= { brwaveRadioEvents 1 } managerIP OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "IP address of NMS station accessing the unit." ::= { brwaveRadioTrapObjs 1 } userName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..32)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "User accessing the unit." ::= { brwaveRadioTrapObjs 2 } brwaveConformance OBJECT IDENTIFIER ::= { brwaveRadio 10 } brwaveRadioGroups OBJECT IDENTIFIER ::= { brwaveConformance 1 } brwaveCompliances OBJECT IDENTIFIER ::= { brwaveConformance 2 } brwaveErrorsOverThreshold NOTIFICATION-TYPE OBJECTS { ifIndex, brwaveRadioUnitTemperature, brwaveRadioTxTemperature, brwaveRadioRSL } STATUS current DESCRIPTION "Link has error rate over threshold." ::= { brwaveRadioEventsV2 1 } brwaveErrorsUnderThreshold NOTIFICATION-TYPE OBJECTS { ifIndex, brwaveRadioUnitTemperature, brwaveRadioTxTemperature, brwaveRadioRSL } STATUS current DESCRIPTION "Link error rate changed from over to under threshold ." ::= { brwaveRadioEventsV2 2 } brwaveUnitTemperatureAbnormal NOTIFICATION-TYPE OBJECTS { brwaveRadioUnitTemperature } STATUS current DESCRIPTION "Radio unit temperature not in normal operating range. Normal range is: -20 to +75 degree Centigrade." ::= { brwaveRadioEventsV2 3 } brwaveUnitTemperatureNormal NOTIFICATION-TYPE OBJECTS { brwaveRadioUnitTemperature } STATUS current DESCRIPTION "Unit temperature restores from abnormal to normal range." ::= { brwaveRadioEventsV2 4 } brwaveTxTemperatureAbnormal NOTIFICATION-TYPE OBJECTS { brwaveRadioTxTemperature } STATUS current DESCRIPTION "Transmitter temperature is not in normal operating range. Normal range is: -20 to +75 degree Centigrade." ::= { brwaveRadioEventsV2 5 } brwaveTxTemperatureNormal NOTIFICATION-TYPE OBJECTS { brwaveRadioTxTemperature } STATUS current DESCRIPTION "Transmitter temperature is restored to normal range." ::= { brwaveRadioEventsV2 6 } brwaveInputVoltageAbnormal NOTIFICATION-TYPE OBJECTS { brwaveRadioInVoltage } STATUS current DESCRIPTION "Unit's input voltage is not in normal range. Normal input voltage > 16 Volts." ::= { brwaveRadioEventsV2 7 } brwaveInputVoltageNormal NOTIFICATION-TYPE OBJECTS { brwaveRadioInVoltage } STATUS current DESCRIPTION "Unit's input voltage is restored to normal range." ::= { brwaveRadioEventsV2 8 } brwaveRslNormal NOTIFICATION-TYPE OBJECTS { brwaveRadioRSL } STATUS current DESCRIPTION "Received Signal Level is normal. Normal signal level RSL > -55.00 dBm (Gigabit) and RSL > -59.00 dBm (Fast Ethernet)." ::= { brwaveRadioEventsV2 10 } brwaveRslMinor NOTIFICATION-TYPE OBJECTS { brwaveRadioRSL } STATUS current DESCRIPTION "Received Signal Leve droped to the level of minor event. RSL from -55.00 to -59.00 dBm (GE Radio) RSL from -59.00 to -65.00 dBm (FE radio)." ::= { brwaveRadioEventsV2 11 } brwaveRslMajor NOTIFICATION-TYPE OBJECTS { brwaveRadioRSL } STATUS current DESCRIPTION "RSL droppped to the level of major event. RSL < -59.00 dBm (GE Radio) or RSL < -65 dBm (FE radio)." ::= { brwaveRadioEventsV2 13 } brwaveConfigChange NOTIFICATION-TYPE STATUS current DESCRIPTION "Configuration changes are performed by WEB client." ::= { brwaveRadioEventsV2 26 } brwaveLoginSuccessfull NOTIFICATION-TYPE STATUS current DESCRIPTION "NMS Loged in successfully." ::= { brwaveRadioEventsV2 27 } brwaveGeToFeSwitch NOTIFICATION-TYPE OBJECTS { brwaveRadioRSL } STATUS current DESCRIPTION "Tx Rate switched from GE to FE." ::= { brwaveRadioEventsV2 28 } brwaveFeToGeSwitch NOTIFICATION-TYPE OBJECTS { brwaveRadioRSL } STATUS current DESCRIPTION "Tx Rate switched from FE to GE." ::= { brwaveRadioEventsV2 29 } brwaveCommonGroup OBJECT-GROUP OBJECTS { brwaveRadioSn, brwaveUnitModel, brwaveTrapCount } STATUS current DESCRIPTION "Collection of common objects." ::= { brwaveRadioGroups 1 } brwaveFactoryGroup OBJECT-GROUP OBJECTS { brwaveRadioTxBand } STATUS current DESCRIPTION "Collection of factory setup objects." ::= { brwaveRadioGroups 2 } brwaveStatusGroup OBJECT-GROUP OBJECTS { brwaveRadioInVoltage, brwaveRadioUnitTemperature, brwaveRadioTxTemperature, brwaveRadioRSL, brwaveRadioRSLVoltage } STATUS current DESCRIPTION "Collection of status objects." ::= { brwaveRadioGroups 3 } END -- end of module BRWAVE-RADIO-MIB.