-- ============================================================================ -- AT-PLUGGABLE-DIAGNOSTICS-MIB, Allied Telesis enterprise MIB: -- Diagnostic objects related to Optical Pluggable modules. -- -- Copyright (c) 2015 by Allied Telesis, Inc. -- All rights reserved. -- -- ============================================================================ AT-PLUGGABLE-DIAGNOSTICS-MIB DEFINITIONS ::= BEGIN IMPORTS DisplayStringUnsized FROM AT-SMI-MIB sysinfo FROM AT-SYSINFO-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI InterfaceIndex FROM IF-MIB; atPluggableDiag MODULE-IDENTITY LAST-UPDATED "201507170000Z" ORGANIZATION "Allied Telesis, Inc" CONTACT-INFO "http://www.alliedtelesis.com" DESCRIPTION "The AT Pluggbale Diagnostics MIB contains objects to retrieve the standard diagnostic information from installed SFP modules." REVISION "201507170000Z" DESCRIPTION "Initial revision" ::= { sysinfo 28 } ---------------------------------------------------------------- -- The Digital Diagnostic monitoring for optical pluggables ---------------------------------------------------------------- atPluggableDiagTable OBJECT IDENTIFIER ::= { atPluggableDiag 1 } ---------------------------------------------------------------- -- Temperature table for Digital Diagnostic monitoring ---------------------------------------------------------------- atPluggableDiagTempTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the various temperature parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 1 } atPluggableDiagTempEntry OBJECT-TYPE SYNTAX AtPluggableDiagTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various temperature parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold." INDEX { atPluggableDiagTempIfIndex, atPluggableDiagTempChannel } ::= { atPluggableDiagTempTable 1 } AtPluggableDiagTempEntry ::= SEQUENCE { atPluggableDiagTempIfIndex InterfaceIndex, atPluggableDiagTempChannel Integer32, atPluggableDiagTempStatusReading Integer32, atPluggableDiagTempCurrentAlarm OCTET STRING, atPluggableDiagTempAlarmMax Integer32, atPluggableDiagTempAlarmMin Integer32, atPluggableDiagTempCurrentWarning OCTET STRING, atPluggableDiagTempWarningMax Integer32, atPluggableDiagTempWarningMin Integer32 } atPluggableDiagTempIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagTempEntry 1 } atPluggableDiagTempChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagTempEntry 2 } atPluggableDiagTempStatusReading OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 degree C" MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature status reading." ::= { atPluggableDiagTempEntry 3 } atPluggableDiagTempCurrentAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature alarm reading." ::= { atPluggableDiagTempEntry 4 } atPluggableDiagTempAlarmMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 degree C" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum temperature alarm threshold value." ::= { atPluggableDiagTempEntry 5 } atPluggableDiagTempAlarmMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 degree C" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum temperature alarm threshold value." ::= { atPluggableDiagTempEntry 6 } atPluggableDiagTempCurrentWarning OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current temperature warnings." ::= { atPluggableDiagTempEntry 7 } atPluggableDiagTempWarningMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 degree C" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum temperature warning threshold value." ::= { atPluggableDiagTempEntry 8 } atPluggableDiagTempWarningMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 degree C" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum temperature warning threshold value." ::= { atPluggableDiagTempEntry 9 } ---------------------------------------------------------------- -- Voltage (Vcc) table for Digital Diagnostic monitoring ---------------------------------------------------------------- atPluggableDiagVccTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the various Voltage (Vcc) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 2 } atPluggableDiagVccEntry OBJECT-TYPE SYNTAX AtPluggableDiagVccEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various Voltage (Vcc) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold." INDEX { atPluggableDiagVccIfIndex, atPluggableDiagVccChannel } ::= { atPluggableDiagVccTable 1 } AtPluggableDiagVccEntry ::= SEQUENCE { atPluggableDiagVccIfIndex InterfaceIndex, atPluggableDiagVccChannel Integer32, atPluggableDiagVccStatusReading Integer32, atPluggableDiagVccCurrentAlarm OCTET STRING, atPluggableDiagVccAlarmMax Integer32, atPluggableDiagVccAlarmMin Integer32, atPluggableDiagVccCurrentWarning OCTET STRING, atPluggableDiagVccWarningMax Integer32, atPluggableDiagVccWarningMin Integer32 } atPluggableDiagVccIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagVccEntry 1 } atPluggableDiagVccChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagVccEntry 2 } atPluggableDiagVccStatusReading OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Voltage (Vcc) status reading." ::= { atPluggableDiagVccEntry 3 } atPluggableDiagVccCurrentAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Voltage (Vcc) alarm reading." ::= { atPluggableDiagVccEntry 4 } atPluggableDiagVccAlarmMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Voltage (Vcc) alarm threshold value." ::= { atPluggableDiagVccEntry 5 } atPluggableDiagVccAlarmMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Voltage (Vcc) alarm threshold value." ::= { atPluggableDiagVccEntry 6 } atPluggableDiagVccCurrentWarning OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Voltage (Vcc) warnings." ::= { atPluggableDiagVccEntry 7 } atPluggableDiagVccWarningMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Voltage (Vcc) warning threshold value." ::= { atPluggableDiagVccEntry 8 } atPluggableDiagVccWarningMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Voltage (Vcc) warning threshold value." ::= { atPluggableDiagVccEntry 9 } ---------------------------------------------------------------- -- Tx Bias Current (mA) table for Digital Diagnostic monitoring ---------------------------------------------------------------- atPluggableDiagTxBiasTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the various Tx Bias Current (mA) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 3 } atPluggableDiagTxBiasEntry OBJECT-TYPE SYNTAX AtPluggableDiagTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various Tx Bias Current (mA) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold." INDEX { atPluggableDiagTxBiasIfIndex, atPluggableDiagTxBiasChannel } ::= { atPluggableDiagTxBiasTable 1 } AtPluggableDiagTxBiasEntry ::= SEQUENCE { atPluggableDiagTxBiasIfIndex InterfaceIndex, atPluggableDiagTxBiasChannel Integer32, atPluggableDiagTxBiasStatusReading Integer32, atPluggableDiagTxBiasCurrentAlarm OCTET STRING, atPluggableDiagTxBiasAlarmMax Integer32, atPluggableDiagTxBiasAlarmMin Integer32, atPluggableDiagTxBiasCurrentWarning OCTET STRING, atPluggableDiagTxBiasWarningMax Integer32, atPluggableDiagTxBiasWarningMin Integer32 } atPluggableDiagTxBiasIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagTxBiasEntry 1 } atPluggableDiagTxBiasChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagTxBiasEntry 2 } atPluggableDiagTxBiasStatusReading OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Bias (mA) status reading." ::= { atPluggableDiagTxBiasEntry 3 } atPluggableDiagTxBiasCurrentAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Bias (mA) alarm reading." ::= { atPluggableDiagTxBiasEntry 4 } atPluggableDiagTxBiasAlarmMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Tx Bias (mA) alarm threshold value." ::= { atPluggableDiagTxBiasEntry 5 } atPluggableDiagTxBiasAlarmMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Tx Bias (mA) alarm threshold value." ::= { atPluggableDiagTxBiasEntry 6 } atPluggableDiagTxBiasCurrentWarning OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Bias (mA) warnings." ::= { atPluggableDiagTxBiasEntry 7 } atPluggableDiagTxBiasWarningMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Tx Bias (mA) warning threshold value." ::= { atPluggableDiagTxBiasEntry 8 } atPluggableDiagTxBiasWarningMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.001 mA" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Tx Bias (mA) warning threshold value." ::= { atPluggableDiagTxBiasEntry 9 } ---------------------------------------------------------------- -- Tx Power (mW) table for Digital Diagnostic monitoring ---------------------------------------------------------------- atPluggableDiagTxPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagTxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the various Tx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 4 } atPluggableDiagTxPowerEntry OBJECT-TYPE SYNTAX AtPluggableDiagTxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various Tx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold." INDEX { atPluggableDiagTxPowerIfIndex, atPluggableDiagTxPowerChannel } ::= { atPluggableDiagTxPowerTable 1 } AtPluggableDiagTxPowerEntry ::= SEQUENCE { atPluggableDiagTxPowerIfIndex InterfaceIndex, atPluggableDiagTxPowerChannel Integer32, atPluggableDiagTxPowerStatusReading Integer32, atPluggableDiagTxPowerCurrentAlarm OCTET STRING, atPluggableDiagTxPowerAlarmMax Integer32, atPluggableDiagTxPowerAlarmMin Integer32, atPluggableDiagTxPowerCurrentWarning OCTET STRING, atPluggableDiagTxPowerWarningMax Integer32, atPluggableDiagTxPowerWarningMin Integer32 } atPluggableDiagTxPowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagTxPowerEntry 1 } atPluggableDiagTxPowerChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagTxPowerEntry 2 } atPluggableDiagTxPowerStatusReading OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Power (mW) status reading." ::= { atPluggableDiagTxPowerEntry 3 } atPluggableDiagTxPowerCurrentAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Power (mW) alarm reading." ::= { atPluggableDiagTxPowerEntry 4 } atPluggableDiagTxPowerAlarmMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Tx Power (mW) alarm threshold value." ::= { atPluggableDiagTxPowerEntry 5 } atPluggableDiagTxPowerAlarmMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Tx Power (mW) alarm threshold value." ::= { atPluggableDiagTxPowerEntry 6 } atPluggableDiagTxPowerCurrentWarning OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Tx Power (mW) warnings." ::= { atPluggableDiagTxPowerEntry 7 } atPluggableDiagTxPowerWarningMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Tx Power (mW) warning threshold value." ::= { atPluggableDiagTxPowerEntry 8 } atPluggableDiagTxPowerWarningMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Tx Power (mW) warning threshold value." ::= { atPluggableDiagTxPowerEntry 9 } ---------------------------------------------------------------- -- Rx Power (mW) table for Digital Diagnostic monitoring ---------------------------------------------------------------- atPluggableDiagRxPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagRxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the various Rx Power (mW) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 5 } atPluggableDiagRxPowerEntry OBJECT-TYPE SYNTAX AtPluggableDiagRxPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various Rx Power (mW) parameters of pluggables such as current status reading, current alarm status, higher and lower alarm threshold, current warning, higher and lower warning threshold." INDEX { atPluggableDiagRxPowerIfIndex, atPluggableDiagRxPowerChannel } ::= { atPluggableDiagRxPowerTable 1 } AtPluggableDiagRxPowerEntry ::= SEQUENCE { atPluggableDiagRxPowerIfIndex InterfaceIndex, atPluggableDiagRxPowerChannel Integer32, atPluggableDiagRxPowerStatusReading Integer32, atPluggableDiagRxPowerCurrentAlarm OCTET STRING, atPluggableDiagRxPowerAlarmMax Integer32, atPluggableDiagRxPowerAlarmMin Integer32, atPluggableDiagRxPowerCurrentWarning OCTET STRING, atPluggableDiagRxPowerWarningMax Integer32, atPluggableDiagRxPowerWarningMin Integer32 } atPluggableDiagRxPowerIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagRxPowerEntry 1 } atPluggableDiagRxPowerChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagRxPowerEntry 2 } atPluggableDiagRxPowerStatusReading OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The current Rx Power (mW) status reading." ::= { atPluggableDiagRxPowerEntry 3 } atPluggableDiagRxPowerCurrentAlarm OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Rx Power (mW) alarm reading." ::= { atPluggableDiagRxPowerEntry 4 } atPluggableDiagRxPowerAlarmMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Rx Power (mW) alarm threshold value." ::= { atPluggableDiagRxPowerEntry 5 } atPluggableDiagRxPowerAlarmMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Rx Power (mW) alarm threshold value." ::= { atPluggableDiagRxPowerEntry 6 } atPluggableDiagRxPowerCurrentWarning OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Rx Power (mW) warnings." ::= { atPluggableDiagRxPowerEntry 7 } atPluggableDiagRxPowerWarningMax OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Rx Power (mW) warning threshold value." ::= { atPluggableDiagRxPowerEntry 8 } atPluggableDiagRxPowerWarningMin OBJECT-TYPE SYNTAX Integer32 UNITS "0.0001 mW" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum Rx Power (mW) warning threshold value." ::= { atPluggableDiagRxPowerEntry 9 } ----------------------------------------------------------------------- -- Rx Loss of Signal (LOS) table for Digital Diagnostic monitoring ----------------------------------------------------------------------- atPluggableDiagRxLosTable OBJECT-TYPE SYNTAX SEQUENCE OF AtPluggableDiagRxLosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of information regarding the Rx Loss of Singal (Los) parameters observed as a part of Digital diagnostics monitoring, for all the optical pluggables installed in the devices." ::= { atPluggableDiagTable 6 } atPluggableDiagRxLosEntry OBJECT-TYPE SYNTAX AtPluggableDiagRxLosEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about various Rx Loss of Singal (Los) parameters of pluggables such as current status reading." INDEX { atPluggableDiagRxLosIfIndex, atPluggableDiagRxLosChannel } ::= { atPluggableDiagRxLosTable 1 } AtPluggableDiagRxLosEntry ::= SEQUENCE { atPluggableDiagRxLosIfIndex InterfaceIndex, atPluggableDiagRxLosChannel Integer32, atPluggableDiagRxLosStatusReading OCTET STRING } atPluggableDiagRxLosIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the pluggable." ::= { atPluggableDiagRxLosEntry 1 } atPluggableDiagRxLosChannel OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel number of the pluggable." ::= { atPluggableDiagRxLosEntry 2 } atPluggableDiagRxLosStatusReading OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The current Rx Los status reading." ::= { atPluggableDiagRxLosEntry 3 } END