-- Ascend mibss7nmi MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSS7NMI-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibsS7Profile OBJECT IDENTIFIER ::= { configuration 121} mibpRITunlStatProfile OBJECT IDENTIFIER ::= { configuration 158} -- The mibsS7Profile table -- -- This table contains parameters for the mibsS7Profile profile -- mibsS7ProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibsS7ProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibsS7Profile profile entries." ::= { mibsS7Profile 1 } mibsS7ProfileEntry OBJECT-TYPE SYNTAX MibsS7ProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibsS7Profile entry containing objects that maps to the parameters of mibsS7Profile profile." INDEX { sS7Profile-Index-o } ::= { mibsS7ProfileTable 1 } MibsS7ProfileEntry ::= SEQUENCE { sS7Profile-Index-o INTEGER, sS7Profile-Enabled INTEGER, sS7Profile-ControlProtocol INTEGER, sS7Profile-PrimaryIpAddress IpAddress, sS7Profile-PrimaryTcpPort INTEGER, sS7Profile-SecondaryIpAddress IpAddress, sS7Profile-SecondaryTcpPort INTEGER, sS7Profile-BayId DisplayString, sS7Profile-SystemType DisplayString, sS7Profile-TransportOptions-Type INTEGER, sS7Profile-TransportOptions-DeviceId INTEGER, sS7Profile-TransportOptions-T1Duration INTEGER, sS7Profile-TransportOptions-T2Duration INTEGER, sS7Profile-TransportOptions-T3Duration INTEGER, sS7Profile-TransportOptions-WindowSize INTEGER, sS7Profile-TransportOptions-AckThreshold INTEGER, sS7Profile-TransportOptions-HeartBeat INTEGER, sS7Profile-TransportOptions-Tos-Active INTEGER, sS7Profile-TransportOptions-Tos-Precedence INTEGER, sS7Profile-TransportOptions-Tos-TypeOfService INTEGER, sS7Profile-TransportOptions-Tos-ApplyTo INTEGER, sS7Profile-TransportOptions-Tos-MarkingType INTEGER, sS7Profile-TransportOptions-Tos-Dscp DisplayString, sS7Profile-UseSystemIpAddressAsSource INTEGER, sS7Profile-IpdcSourceAdddress IpAddress, sS7Profile-Vrouter DisplayString, sS7Profile-CongestionControl-CongestionControlType INTEGER, sS7Profile-CongestionControl-Cl1Level INTEGER, sS7Profile-CongestionControl-Cl1Action INTEGER, sS7Profile-CongestionControl-Cl2Level INTEGER, sS7Profile-CongestionControl-Cl2Action INTEGER, sS7Profile-SignalingHeartbeat-Enabled INTEGER, sS7Profile-SignalingHeartbeat-Interval INTEGER, sS7Profile-ResilienceOptions-Type INTEGER, sS7Profile-ResilienceOptions-Duration INTEGER, sS7Profile-PriTunnelingOptions-Enabled INTEGER, sS7Profile-PriTunnelingOptions-Duration INTEGER, sS7Profile-Action-o INTEGER } sS7Profile-Index-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsS7ProfileEntry 1 } sS7Profile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to 'no', interface to the SS7 gateway is disabled." ::= { mibsS7ProfileEntry 2 } sS7Profile-ControlProtocol OBJECT-TYPE SYNTAX INTEGER { asgcp (1), ipdc0X (2), q931Plus (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Control protocol between the access server and the signaling gateway." ::= { mibsS7ProfileEntry 3 } sS7Profile-PrimaryIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the primary SS7 gateway." ::= { mibsS7ProfileEntry 4 } sS7Profile-PrimaryTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TCP port on primary SS7 gateway." ::= { mibsS7ProfileEntry 5 } sS7Profile-SecondaryIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the secondary SS7 gateway." ::= { mibsS7ProfileEntry 6 } sS7Profile-SecondaryTcpPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TCP port on the secondary SS7 gateway." ::= { mibsS7ProfileEntry 7 } sS7Profile-BayId OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Bay ID defines the bay this device belongs to. Used for registration purposes only. The content of this field is reported to the gateway during the device registration process." ::= { mibsS7ProfileEntry 8 } sS7Profile-SystemType OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Model ID and/or type of equipment. Used for device registration only. Must be listed in the database on the Gateway." ::= { mibsS7ProfileEntry 9 } sS7Profile-TransportOptions-Type OBJECT-TYPE SYNTAX INTEGER { ascend (1), tcpEncaps2 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of transport layer that is to be used" ::= { mibsS7ProfileEntry 10 } sS7Profile-TransportOptions-DeviceId OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A code that uniquely identifies this device to the Gateway. If multiple remote access servers are configured to use the same signaling gateway, every one of those servers must be assigned an identifier that is unique within the group." ::= { mibsS7ProfileEntry 11 } sS7Profile-TransportOptions-T1Duration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of the ACK delay timer in milliseconds. This timer specifies the maximum delay for an acknowledgement when an I-frame is received. Default value is 1000 (1 second). The value must be less than T2 on the peer." ::= { mibsS7ProfileEntry 12 } sS7Profile-TransportOptions-T2Duration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of the transmission timeout timer in milliseconds. This timer specifies how long this endpoint should wait for an acknowledgement. Default value is 3000 (3 seconds). The value must be greater than T1 on the peer." ::= { mibsS7ProfileEntry 13 } sS7Profile-TransportOptions-T3Duration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Value of the persistent error timer in milliseconds. This timer specifies the maximum duration of attempts to re-establish a link before the transport layer flushes the data queues and sends an error indication up. Default value is 30000 (30 seconds)." ::= { mibsS7ProfileEntry 14 } sS7Profile-TransportOptions-WindowSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Maximum number of sequentially numbered data packets that can be sent while pending acknowledgement at any given time. Default value is 7." ::= { mibsS7ProfileEntry 15 } sS7Profile-TransportOptions-AckThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The threshold for triggering an acknowledgement while receiving data packets. As soon as the specified number of packets is received, an ACK is sent back regardless of the value of T1 timer. The value of this parameter may not be greater than the window size. Default value is 6." ::= { mibsS7ProfileEntry 16 } sS7Profile-TransportOptions-HeartBeat OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to 'no', layer 2 heartbeat mechanism is not enabled." ::= { mibsS7ProfileEntry 17 } sS7Profile-TransportOptions-Tos-Active OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Activate type of service for this connection." ::= { mibsS7ProfileEntry 34 } sS7Profile-TransportOptions-Tos-Precedence OBJECT-TYPE SYNTAX INTEGER { n-000 (1), n-001 (33), n-010 (65), n-011 (97), n-100 (129), n-101 (161), n-110 (193), n-111 (225) } ACCESS read-write STATUS mandatory DESCRIPTION "Tag the precedence bits (priority bits) in the TOS octet of IP datagram header with this value when match occurs." ::= { mibsS7ProfileEntry 35 } sS7Profile-TransportOptions-Tos-TypeOfService OBJECT-TYPE SYNTAX INTEGER { normal (1), cost (3), reliability (5), throughput (9), latency (17) } ACCESS read-write STATUS mandatory DESCRIPTION "Tag the type of service field in the TOS octet of IP datagram header with this value when match occurs." ::= { mibsS7ProfileEntry 36 } sS7Profile-TransportOptions-Tos-ApplyTo OBJECT-TYPE SYNTAX INTEGER { incoming (1025), outgoing (2049), both (3073) } ACCESS read-write STATUS mandatory DESCRIPTION "Define how the type-of-service applies to data flow for this connection." ::= { mibsS7ProfileEntry 37 } sS7Profile-TransportOptions-Tos-MarkingType OBJECT-TYPE SYNTAX INTEGER { precedenceTos (1), dscp (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Select type of packet marking." ::= { mibsS7ProfileEntry 38 } sS7Profile-TransportOptions-Tos-Dscp OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "DSCP tag to be used in marking of the packets (if marking-type = dscp)." ::= { mibsS7ProfileEntry 39 } sS7Profile-UseSystemIpAddressAsSource OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to 'yes', use configured System IP Address as source ip address. When set to 'no', use IP Address of outgoing interface as source ip address." ::= { mibsS7ProfileEntry 18 } sS7Profile-IpdcSourceAdddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address to be used on the private network" ::= { mibsS7ProfileEntry 32 } sS7Profile-Vrouter OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the virtual router to be used." ::= { mibsS7ProfileEntry 33 } sS7Profile-CongestionControl-CongestionControlType OBJECT-TYPE SYNTAX INTEGER { none (1), l3QueueDepth (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of the congestion control algorithm to use." ::= { mibsS7ProfileEntry 19 } sS7Profile-CongestionControl-Cl1Level OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The level at which 'congestion level 1' indication will be issued. The value is interpreted according to the configured congestion control 'type'." ::= { mibsS7ProfileEntry 20 } sS7Profile-CongestionControl-Cl1Action OBJECT-TYPE SYNTAX INTEGER { ignore (1), sendInfoToMgc (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Action taken when congestion level 1 (defined by the value of cl1-level) is reached." ::= { mibsS7ProfileEntry 21 } sS7Profile-CongestionControl-Cl2Level OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The level at which 'congestion level 2' indication will be issued. The value is interpreted according to the configured congestion control 'type'." ::= { mibsS7ProfileEntry 22 } sS7Profile-CongestionControl-Cl2Action OBJECT-TYPE SYNTAX INTEGER { ignore (1), sendInfoToMgc (2), rejectNewCall (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Action taken when congestion level 2 (defined by the value of cl2-level) is reached." ::= { mibsS7ProfileEntry 23 } sS7Profile-SignalingHeartbeat-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to yes, TNT will generate signaling heartbeat to MGC based on the interval configured in signaling-heartbeat interval." ::= { mibsS7ProfileEntry 24 } sS7Profile-SignalingHeartbeat-Interval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The time interval in seconds for layer 3 heartbeat messages." ::= { mibsS7ProfileEntry 25 } sS7Profile-ResilienceOptions-Type OBJECT-TYPE SYNTAX INTEGER { releaseAll (1), maintainActive (2), timedRelease (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of resilience action required when line state changes." ::= { mibsS7ProfileEntry 27 } sS7Profile-ResilienceOptions-Duration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The duration in milli seconds for which calls should be maintained when line state changes. Valid only if the type is configured as timed-release." ::= { mibsS7ProfileEntry 28 } sS7Profile-PriTunnelingOptions-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When set to yes, we will synchronize the d-channel status with the IPDC signaling link state." ::= { mibsS7ProfileEntry 29 } sS7Profile-PriTunnelingOptions-Duration OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The duration in milliseconds after which bringing down D-channel of tunneled-pri-signaling lines will be initiated." ::= { mibsS7ProfileEntry 30 } sS7Profile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibsS7ProfileEntry 26 } -- The mibpRITunlStatProfile table -- -- This table contains parameters for the mibpRITunlStatProfile profile -- mibpRITunlStatProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibpRITunlStatProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibpRITunlStatProfile profile entries." ::= { mibpRITunlStatProfile 1 } mibpRITunlStatProfileEntry OBJECT-TYPE SYNTAX MibpRITunlStatProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibpRITunlStatProfile entry containing objects that maps to the parameters of mibpRITunlStatProfile profile." INDEX { pRITunlStatProfile-Index-o } ::= { mibpRITunlStatProfileTable 1 } MibpRITunlStatProfileEntry ::= SEQUENCE { pRITunlStatProfile-Index-o INTEGER, pRITunlStatProfile-Action-o INTEGER } pRITunlStatProfile-Index-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibpRITunlStatProfileEntry 1 } pRITunlStatProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibpRITunlStatProfileEntry 2 } END