-- Ascend mibsdslnet MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBSDSLNET-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibsdslNetworkProfile OBJECT IDENTIFIER ::= { configuration 8} -- The mibsdslNetworkProfile table -- -- This table contains parameters for the mibsdslNetworkProfile profile -- mibsdslNetworkProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibsdslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibsdslNetworkProfile profile entries." ::= { mibsdslNetworkProfile 1 } mibsdslNetworkProfileEntry OBJECT-TYPE SYNTAX MibsdslNetworkProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibsdslNetworkProfile entry containing objects that maps to the parameters of mibsdslNetworkProfile profile." INDEX { sdslNetworkProfile-Shelf-o, sdslNetworkProfile-Slot-o, sdslNetworkProfile-Item-o } ::= { mibsdslNetworkProfileTable 1 } MibsdslNetworkProfileEntry ::= SEQUENCE { sdslNetworkProfile-Shelf-o INTEGER, sdslNetworkProfile-Slot-o INTEGER, sdslNetworkProfile-Item-o INTEGER, sdslNetworkProfile-Name DisplayString, sdslNetworkProfile-PhysicalAddress-Shelf INTEGER, sdslNetworkProfile-PhysicalAddress-Slot INTEGER, sdslNetworkProfile-PhysicalAddress-ItemNumber INTEGER, sdslNetworkProfile-Enabled INTEGER, sdslNetworkProfile-SparingMode INTEGER, sdslNetworkProfile-ProfileNumber INTEGER, sdslNetworkProfile-IgnoreLineup INTEGER, sdslNetworkProfile-LineConfig-TrunkGroup INTEGER, sdslNetworkProfile-LineConfig-NailedGroup INTEGER, sdslNetworkProfile-LineConfig-VpSwitchingVpi INTEGER, sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER, sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER, sdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER, sdslNetworkProfile-LineConfig-Activation INTEGER, sdslNetworkProfile-LineConfig-DataSense INTEGER, sdslNetworkProfile-LineConfig-SdslDataFormat INTEGER, sdslNetworkProfile-LineConfig-DataRateMode INTEGER, sdslNetworkProfile-LineConfig-MaxRate INTEGER, sdslNetworkProfile-LineConfig-AutoBaseRate INTEGER, sdslNetworkProfile-LineConfig-UnitType INTEGER, sdslNetworkProfile-LineConfig-Enabled INTEGER, sdslNetworkProfile-LineConfig-LineMode INTEGER, sdslNetworkProfile-LineConfig-LoopBack INTEGER, sdslNetworkProfile-DhcpConfig-IpAddress IpAddress, sdslNetworkProfile-DhcpConfig-MaxLease INTEGER, sdslNetworkProfile-Action-o INTEGER } sdslNetworkProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 1 } sdslNetworkProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 2 } sdslNetworkProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 3 } sdslNetworkProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "For future use. The current design does not use the name field but instead references Sdsl lines by the physical address; we may in the future support referencing Sdsl lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Sdsl line physical address." ::= { mibsdslNetworkProfileEntry 4 } sdslNetworkProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibsdslNetworkProfileEntry 5 } sdslNetworkProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibsdslNetworkProfileEntry 6 } sdslNetworkProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibsdslNetworkProfileEntry 7 } sdslNetworkProfile-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { mibsdslNetworkProfileEntry 8 } sdslNetworkProfile-SparingMode OBJECT-TYPE SYNTAX INTEGER { inactive (1), manual (2), automatic (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Port sparing operational mode for this port." ::= { mibsdslNetworkProfileEntry 31 } sdslNetworkProfile-ProfileNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "For potential backwards compatibility. The current design consists of one line profile numbered 0." ::= { mibsdslNetworkProfileEntry 9 } sdslNetworkProfile-IgnoreLineup OBJECT-TYPE SYNTAX INTEGER { systemDefined (1), no (2), yes (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Ignore line up value for this port." ::= { mibsdslNetworkProfileEntry 34 } sdslNetworkProfile-LineConfig-TrunkGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The trunk group to which this line is assigned. 0 means this line is not part of a trunk group." ::= { mibsdslNetworkProfileEntry 10 } sdslNetworkProfile-LineConfig-NailedGroup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group." ::= { mibsdslNetworkProfileEntry 11 } sdslNetworkProfile-LineConfig-VpSwitchingVpi OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY." ::= { mibsdslNetworkProfileEntry 27 } sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 12 } sdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed." ::= { mibsdslNetworkProfileEntry 13 } sdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 14 } sdslNetworkProfile-LineConfig-Activation OBJECT-TYPE SYNTAX INTEGER { static (1), dsrActive (2), dcdDsrActive (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Line activation mode." ::= { mibsdslNetworkProfileEntry 15 } sdslNetworkProfile-LineConfig-DataSense OBJECT-TYPE SYNTAX INTEGER { normal (1), inv (2) } ACCESS read-write STATUS mandatory DESCRIPTION "If this value is set to Inverted, the Tx data will be inverted and the Rx data will be expected to be inverted. Otherwise the Tx and Rx data will be non-inverted." ::= { mibsdslNetworkProfileEntry 26 } sdslNetworkProfile-LineConfig-SdslDataFormat OBJECT-TYPE SYNTAX INTEGER { serial (1) } ACCESS read-write STATUS mandatory DESCRIPTION "If this value is set to Mag bit 1st, the sdsl-data-format outputs the magnitude before the sign bit. Otherwise with value set to sign bit 1st, the sdsl-data-format outputs the sign before the magnitude bit. This is our default." ::= { mibsdslNetworkProfileEntry 30 } sdslNetworkProfile-LineConfig-DataRateMode OBJECT-TYPE SYNTAX INTEGER { autobaud (2), singlebaud (3), fastautobaud (4) } ACCESS read-write STATUS mandatory DESCRIPTION "The data rate mode defines the mode for modem training. This parameter does not pertain to the old 16 port sdsl card." ::= { mibsdslNetworkProfileEntry 19 } sdslNetworkProfile-LineConfig-MaxRate OBJECT-TYPE SYNTAX INTEGER { n-144000 (1), n-272000 (2), n-400000 (3), n-528000 (4), n-784000 (5), n-1168000 (6), n-1552000 (7), n-2320000 (8), n-160000 (9), n-192000 (10), n-208000 (11), n-384000 (12), n-416000 (13), n-768000 (14), n-1040000 (15), n-1152000 (16), n-1536000 (17), n-1568000 (18), n-1680000 (19), n-1920000 (20), n-2160000 (21) } ACCESS read-write STATUS mandatory DESCRIPTION "The symetrical interface rate. This parameter does not pertain to the old 16 port sdsl card." ::= { mibsdslNetworkProfileEntry 20 } sdslNetworkProfile-LineConfig-AutoBaseRate OBJECT-TYPE SYNTAX INTEGER { n-144000 (1), n-272000 (2), n-400000 (3), n-528000 (4), n-784000 (5), n-1168000 (6), n-1552000 (7), n-2320000 (8), n-160000 (9), n-192000 (10), n-208000 (11), n-384000 (12), n-416000 (13), n-768000 (14), n-1040000 (15), n-1152000 (16), n-1536000 (17), n-1568000 (18), n-1680000 (19), n-1920000 (20), n-2160000 (21) } ACCESS read-write STATUS mandatory DESCRIPTION "When the Rate Mode is set to auto. This parameter defines the base rate that the auto rate mechanism uses to start its initial training with." ::= { mibsdslNetworkProfileEntry 25 } sdslNetworkProfile-LineConfig-UnitType OBJECT-TYPE SYNTAX INTEGER { coe (1), cpe (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation. This parameter does not pertain to the old 16 port sdsl card." ::= { mibsdslNetworkProfileEntry 21 } sdslNetworkProfile-LineConfig-Enabled OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "TRUE if the line is enabled, otherwise FALSE." ::= { mibsdslNetworkProfileEntry 24 } sdslNetworkProfile-LineConfig-LineMode OBJECT-TYPE SYNTAX INTEGER { atm (1), hdlc (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This line can be configured to run in ATM or HDLC serial mode." ::= { mibsdslNetworkProfileEntry 32 } sdslNetworkProfile-LineConfig-LoopBack OBJECT-TYPE SYNTAX INTEGER { none (1), analog (2), digital (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Configuration of different modem loopbacks." ::= { mibsdslNetworkProfileEntry 33 } sdslNetworkProfile-DhcpConfig-IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The static address to be assigned to dhcp client." ::= { mibsdslNetworkProfileEntry 28 } sdslNetworkProfile-DhcpConfig-MaxLease OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number representing maximum number lease requests that would be granted." ::= { mibsdslNetworkProfileEntry 29 } sdslNetworkProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibsdslNetworkProfileEntry 22 } END