-- Ascend mibport1 MIB -- -- Ascend Communications, Inc -- 1275 Harbor Bay Pkwy -- Alameda, CA 94502 -- +1 510 769 6001 -- info@ascend.com -- -- Copyright (c) 1993-1999 Ascend Communications, Inc. -- All rights reserved. -- -- Do not edit this file directly. -- It is generated automatically by mibgen for use with -- TAOS version 10.0.1 or newer. -- ASCEND-MIBPORT1-MIB DEFINITIONS ::= BEGIN IMPORTS configuration FROM ASCEND-MIB IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- If any of the MIB compilers have problems with the DisplayString -- or PhysAddress, uncomment the next two lines. DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING mibportProfile OBJECT IDENTIFIER ::= { configuration 102} -- The mibportProfile table -- -- This table contains parameters for the mibportProfile profile -- mibportProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF MibportProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A list of mibportProfile profile entries." ::= { mibportProfile 1 } mibportProfileEntry OBJECT-TYPE SYNTAX MibportProfileEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A mibportProfile entry containing objects that maps to the parameters of mibportProfile profile." INDEX { portProfile-Shelf-o, portProfile-Slot-o, portProfile-Item-o } ::= { mibportProfileTable 1 } MibportProfileEntry ::= SEQUENCE { portProfile-Shelf-o INTEGER, portProfile-Slot-o INTEGER, portProfile-Item-o INTEGER, portProfile-PhysicalAddress-Shelf INTEGER, portProfile-PhysicalAddress-Slot INTEGER, portProfile-PhysicalAddress-ItemNumber INTEGER, portProfile-Name DisplayString, portProfile-LastModificationTime INTEGER, portProfile-PortAnswerNumber1 DisplayString, portProfile-PortAnswerNumber2 DisplayString, portProfile-PortAnswerNumber3 DisplayString, portProfile-PortAnswerNumber4 DisplayString, portProfile-oIdle INTEGER, portProfile-oDial INTEGER, portProfile-PortAnswer INTEGER, portProfile-oClear INTEGER, portProfile-PortMinPriBw INTEGER, portProfile-PortTerminalTiming INTEGER, portProfile-oRS366Esc INTEGER, portProfile-oEarlyCD INTEGER, portProfile-PortDs0MinReset INTEGER, portProfile-MaxPortDs0Mins INTEGER, portProfile-MaxCallDurationTimer INTEGER, portProfile-DialPlan INTEGER, portProfile-TrunkGroupsNa INTEGER, portProfile-PortPassword DisplayString, portProfile-Action-o INTEGER } portProfile-Shelf-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 1 } portProfile-Slot-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 2 } portProfile-Item-o OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 3 } portProfile-PhysicalAddress-Shelf OBJECT-TYPE SYNTAX INTEGER { anyShelf (1), shelf1 (2), shelf2 (3), shelf3 (4), shelf4 (5), shelf5 (6), shelf6 (7), shelf7 (8), shelf8 (9), shelf9 (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the shelf that the addressed physical device resides on." ::= { mibportProfileEntry 4 } portProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibportProfileEntry 5 } portProfile-PhysicalAddress-ItemNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "A number that specifies an addressable entity within the context of shelf and slot." ::= { mibportProfileEntry 6 } portProfile-Name OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Ports can be named, e.g. CODEC, Router, etc. The name is provided by the user. It is a standard null terminated ASCII string." ::= { mibportProfileEntry 7 } portProfile-LastModificationTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 8 } portProfile-PortAnswerNumber1 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are answered." ::= { mibportProfileEntry 9 } portProfile-PortAnswerNumber2 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are answered." ::= { mibportProfileEntry 10 } portProfile-PortAnswerNumber3 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are answered." ::= { mibportProfileEntry 11 } portProfile-PortAnswerNumber4 OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are answered." ::= { mibportProfileEntry 12 } portProfile-oIdle OBJECT-TYPE SYNTAX INTEGER { none (1), call (2) } ACCESS read-write STATUS mandatory DESCRIPTION "What to do when a port goes idle." ::= { mibportProfileEntry 13 } portProfile-oDial OBJECT-TYPE SYNTAX INTEGER { portDialTerminal (1), portDialDtr (2), portDialRs366 (3), portDialRs366x (4), portDialV25bis (5), portDialV25bisC (6), portDialX21 (7), portDialX21x (8), portDialX21Ptel (9), numberOfPortDial (10) } ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are originated." ::= { mibportProfileEntry 14 } portProfile-PortAnswer OBJECT-TYPE SYNTAX INTEGER { portAnswerAuto (1), portAnswerDtr (2), portAnswerDtrRing (3), portAnswerV25bis (4), portAnswerV25bisC (5), portAnswerTerminal (6), portAnswerNone (7), portAnswerX21 (8), portAnswerAutoManual (9), numberOfPortAnswer (10) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 15 } portProfile-oClear OBJECT-TYPE SYNTAX INTEGER { dtrActive (1), dtrInactive (2), rtsActive (3), rtsInactive (4), terminal (5) } ACCESS read-write STATUS mandatory DESCRIPTION "The way in which calls are cleared, as given above." ::= { mibportProfileEntry 16 } portProfile-PortMinPriBw OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minimum priority bandwidth allocated to this port. Part of IDBM." ::= { mibportProfileEntry 17 } portProfile-PortTerminalTiming OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Terminal timing enabled for this port?" ::= { mibportProfileEntry 18 } portProfile-oRS366Esc OBJECT-TYPE SYNTAX INTEGER { star (1), pound (2), n-5 (3), n-6 (4), n-7 (5), n-9 (6), n-0 (7), n-00 (8), numberEsc366 (9) } ACCESS read-write STATUS mandatory DESCRIPTION "RS-366 dialing escape character." ::= { mibportProfileEntry 19 } portProfile-oEarlyCD OBJECT-TYPE SYNTAX INTEGER { none (1), answer (2), originate (3), both (4) } ACCESS read-write STATUS mandatory DESCRIPTION "If and when to perform early DCD on the host port." ::= { mibportProfileEntry 20 } portProfile-PortDs0MinReset OBJECT-TYPE SYNTAX INTEGER { off (1), daily (2), monthly (3) } ACCESS read-write STATUS mandatory DESCRIPTION "For billing-cap features related to this port, the duration for the billing cap reset or disabled if apprpriate." ::= { mibportProfileEntry 21 } portProfile-MaxPortDs0Mins OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of minutes that can be billed to this port in the duration set above. If the number exceeds the value set, all switched-calls will be cleared by the system." ::= { mibportProfileEntry 22 } portProfile-MaxCallDurationTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum length of time for a call to be active on this port. If a call is up longer than this time, the call is cleared automatically. This is all part of the no-surprises phone bill feature set." ::= { mibportProfileEntry 23 } portProfile-DialPlan OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 24 } portProfile-TrunkGroupsNa OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 25 } portProfile-PortPassword OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "Port password used to authenticate DBA call's password. Authentication is automatic if port password is not defined." ::= { mibportProfileEntry 26 } portProfile-Action-o OBJECT-TYPE SYNTAX INTEGER { noAction (1), createProfile (2), deleteProfile (3) } ACCESS read-write STATUS mandatory DESCRIPTION "" ::= { mibportProfileEntry 27 } END