AC-PM-SS7-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TAddress, DisplayString, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress FROM RFC1155-SMI Unsigned32, Integer32, enterprises FROM SNMPv2-SMI SnmpAdminString FROM SNMP-FRAMEWORK-MIB audioCodes, acRegistrations, acGeneric, acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB; acPMSS7 MODULE-IDENTITY LAST-UPDATED "200909231811Z" --Wednesday, September 23, 2009 ORGANIZATION "AudioCodes Ltd" CONTACT-INFO "Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com" DESCRIPTION "The AC-PM-SS7 MIB offers performance monitoring For the SS7 related elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-SS7 MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded." ::= {acPerformance 13} acPMSS7Configuration OBJECT IDENTIFIER ::= {acPMSS7 1} acPMSS7ConfigurationPeriodLength OBJECT-TYPE SYNTAX Unsigned32 (0..894780) MAX-ACCESS read-write STATUS current DESCRIPTION "Length of monitoring intervals for entire MIB. Time is in minutes. Access: Online." ::= {acPMSS7Configuration 1} acPMSS7ConfigurationResetTotalCounters OBJECT-TYPE SYNTAX INTEGER { resetCountersDone(1) , resetTotalCounters(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Access: Online." ::= {acPMSS7Configuration 2} acPMSS7Data OBJECT IDENTIFIER ::= {acPMSS7 2} acPMSS7DataTimeFromStartOfInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The time in seconds since the start of the current interval. MIB specific." ::= {acPMSS7Data 1} acPMSS7Links OBJECT IDENTIFIER ::= {acPMSS7Data 31} -- **************************************** -- acPMSS7TxMSU table declaration -- **************************************** acPMSS7TxMSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted MSU's per SS7 link." ::= {acPMSS7Links 1} -- **************************************** -- acPMSS7TxMSU table entry -- **************************************** acPMSS7TxMSUEntry OBJECT-TYPE SYNTAX AcPMSS7TxMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxMSULink,acPMSS7TxMSUInterval} ::= {acPMSS7TxMSUTable 1} -- **************************************** -- acPMSS7TxMSU TABLE -- **************************************** AcPMSS7TxMSUEntry ::= SEQUENCE { acPMSS7TxMSULink Unsigned32, acPMSS7TxMSUInterval Unsigned32, acPMSS7TxMSUVal Counter32, acPMSS7TxMSUTotal Integer32 } acPMSS7TxMSULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7TxMSUEntry 1} acPMSS7TxMSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxMSUEntry 2} acPMSS7TxMSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxMSUEntry 3} acPMSS7TxMSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxMSUEntry 4} -- **************************************** -- acPMSS7RxMSU table declaration -- **************************************** acPMSS7RxMSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received MSU's per SS7 link." ::= {acPMSS7Links 2} -- **************************************** -- acPMSS7RxMSU table entry -- **************************************** acPMSS7RxMSUEntry OBJECT-TYPE SYNTAX AcPMSS7RxMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxMSULink,acPMSS7RxMSUInterval} ::= {acPMSS7RxMSUTable 1} -- **************************************** -- acPMSS7RxMSU TABLE -- **************************************** AcPMSS7RxMSUEntry ::= SEQUENCE { acPMSS7RxMSULink Unsigned32, acPMSS7RxMSUInterval Unsigned32, acPMSS7RxMSUVal Counter32, acPMSS7RxMSUTotal Integer32 } acPMSS7RxMSULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7RxMSUEntry 1} acPMSS7RxMSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxMSUEntry 2} acPMSS7RxMSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxMSUEntry 3} acPMSS7RxMSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxMSUEntry 4} -- **************************************** -- acPMSS7TxLSSU table declaration -- **************************************** acPMSS7TxLSSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxLSSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted LSSU's per SS7 link." ::= {acPMSS7Links 3} -- **************************************** -- acPMSS7TxLSSU table entry -- **************************************** acPMSS7TxLSSUEntry OBJECT-TYPE SYNTAX AcPMSS7TxLSSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxLSSULink,acPMSS7TxLSSUInterval} ::= {acPMSS7TxLSSUTable 1} -- **************************************** -- acPMSS7TxLSSU TABLE -- **************************************** AcPMSS7TxLSSUEntry ::= SEQUENCE { acPMSS7TxLSSULink Unsigned32, acPMSS7TxLSSUInterval Unsigned32, acPMSS7TxLSSUVal Counter32, acPMSS7TxLSSUTotal Integer32 } acPMSS7TxLSSULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7TxLSSUEntry 1} acPMSS7TxLSSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxLSSUEntry 2} acPMSS7TxLSSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxLSSUEntry 3} acPMSS7TxLSSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxLSSUEntry 4} -- **************************************** -- acPMSS7RxLSSU table declaration -- **************************************** acPMSS7RxLSSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxLSSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received LSSU's per SS7 link." ::= {acPMSS7Links 4} -- **************************************** -- acPMSS7RxLSSU table entry -- **************************************** acPMSS7RxLSSUEntry OBJECT-TYPE SYNTAX AcPMSS7RxLSSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxLSSULink,acPMSS7RxLSSUInterval} ::= {acPMSS7RxLSSUTable 1} -- **************************************** -- acPMSS7RxLSSU TABLE -- **************************************** AcPMSS7RxLSSUEntry ::= SEQUENCE { acPMSS7RxLSSULink Unsigned32, acPMSS7RxLSSUInterval Unsigned32, acPMSS7RxLSSUVal Counter32, acPMSS7RxLSSUTotal Integer32 } acPMSS7RxLSSULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7RxLSSUEntry 1} acPMSS7RxLSSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxLSSUEntry 2} acPMSS7RxLSSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxLSSUEntry 3} acPMSS7RxLSSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxLSSUEntry 4} -- **************************************** -- acPMSS7TxFISU table declaration -- **************************************** acPMSS7TxFISUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxFISUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted FISU's per SS7 link." ::= {acPMSS7Links 5} -- **************************************** -- acPMSS7TxFISU table entry -- **************************************** acPMSS7TxFISUEntry OBJECT-TYPE SYNTAX AcPMSS7TxFISUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxFISULink,acPMSS7TxFISUInterval} ::= {acPMSS7TxFISUTable 1} -- **************************************** -- acPMSS7TxFISU TABLE -- **************************************** AcPMSS7TxFISUEntry ::= SEQUENCE { acPMSS7TxFISULink Unsigned32, acPMSS7TxFISUInterval Unsigned32, acPMSS7TxFISUVal Counter32, acPMSS7TxFISUTotal Integer32 } acPMSS7TxFISULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7TxFISUEntry 1} acPMSS7TxFISUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxFISUEntry 2} acPMSS7TxFISUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxFISUEntry 3} acPMSS7TxFISUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxFISUEntry 4} -- **************************************** -- acPMSS7RxFISU table declaration -- **************************************** acPMSS7RxFISUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxFISUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received FISU's per SS7 link." ::= {acPMSS7Links 6} -- **************************************** -- acPMSS7RxFISU table entry -- **************************************** acPMSS7RxFISUEntry OBJECT-TYPE SYNTAX AcPMSS7RxFISUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxFISULink,acPMSS7RxFISUInterval} ::= {acPMSS7RxFISUTable 1} -- **************************************** -- acPMSS7RxFISU TABLE -- **************************************** AcPMSS7RxFISUEntry ::= SEQUENCE { acPMSS7RxFISULink Unsigned32, acPMSS7RxFISUInterval Unsigned32, acPMSS7RxFISUVal Counter32, acPMSS7RxFISUTotal Integer32 } acPMSS7RxFISULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7RxFISUEntry 1} acPMSS7RxFISUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxFISUEntry 2} acPMSS7RxFISUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxFISUEntry 3} acPMSS7RxFISUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxFISUEntry 4} -- **************************************** -- acPMSS7TxSignalUnits table declaration -- **************************************** acPMSS7TxSignalUnitsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxSignalUnitsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted Signaling units per SS7 link" ::= {acPMSS7Links 7} -- **************************************** -- acPMSS7TxSignalUnits table entry -- **************************************** acPMSS7TxSignalUnitsEntry OBJECT-TYPE SYNTAX AcPMSS7TxSignalUnitsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxSignalUnitsLink,acPMSS7TxSignalUnitsInterval} ::= {acPMSS7TxSignalUnitsTable 1} -- **************************************** -- acPMSS7TxSignalUnits TABLE -- **************************************** AcPMSS7TxSignalUnitsEntry ::= SEQUENCE { acPMSS7TxSignalUnitsLink Unsigned32, acPMSS7TxSignalUnitsInterval Unsigned32, acPMSS7TxSignalUnitsVal Counter32, acPMSS7TxSignalUnitsTotal Integer32 } acPMSS7TxSignalUnitsLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7TxSignalUnitsEntry 1} acPMSS7TxSignalUnitsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxSignalUnitsEntry 2} acPMSS7TxSignalUnitsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxSignalUnitsEntry 3} acPMSS7TxSignalUnitsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxSignalUnitsEntry 4} -- **************************************** -- acPMSS7RxSignalUnits table declaration -- **************************************** acPMSS7RxSignalUnitsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxSignalUnitsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received Signaling units per SS7 link" ::= {acPMSS7Links 8} -- **************************************** -- acPMSS7RxSignalUnits table entry -- **************************************** acPMSS7RxSignalUnitsEntry OBJECT-TYPE SYNTAX AcPMSS7RxSignalUnitsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxSignalUnitsLink,acPMSS7RxSignalUnitsInterval} ::= {acPMSS7RxSignalUnitsTable 1} -- **************************************** -- acPMSS7RxSignalUnits TABLE -- **************************************** AcPMSS7RxSignalUnitsEntry ::= SEQUENCE { acPMSS7RxSignalUnitsLink Unsigned32, acPMSS7RxSignalUnitsInterval Unsigned32, acPMSS7RxSignalUnitsVal Counter32, acPMSS7RxSignalUnitsTotal Integer32 } acPMSS7RxSignalUnitsLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7RxSignalUnitsEntry 1} acPMSS7RxSignalUnitsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxSignalUnitsEntry 2} acPMSS7RxSignalUnitsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxSignalUnitsEntry 3} acPMSS7RxSignalUnitsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxSignalUnitsEntry 4} -- **************************************** -- acPMSS7TxOctets table declaration -- **************************************** acPMSS7TxOctetsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxOctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted Octets per SS7 link - Q.752 3.1" ::= {acPMSS7Links 9} -- **************************************** -- acPMSS7TxOctets table entry -- **************************************** acPMSS7TxOctetsEntry OBJECT-TYPE SYNTAX AcPMSS7TxOctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxOctetsLink,acPMSS7TxOctetsInterval} ::= {acPMSS7TxOctetsTable 1} -- **************************************** -- acPMSS7TxOctets TABLE -- **************************************** AcPMSS7TxOctetsEntry ::= SEQUENCE { acPMSS7TxOctetsLink Unsigned32, acPMSS7TxOctetsInterval Unsigned32, acPMSS7TxOctetsVal Counter32, acPMSS7TxOctetsTotal Integer32 } acPMSS7TxOctetsLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7TxOctetsEntry 1} acPMSS7TxOctetsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxOctetsEntry 2} acPMSS7TxOctetsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxOctetsEntry 3} acPMSS7TxOctetsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxOctetsEntry 4} -- **************************************** -- acPMSS7RxOctets table declaration -- **************************************** acPMSS7RxOctetsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxOctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received Octets per SS7 link - Q.752 3.4" ::= {acPMSS7Links 10} -- **************************************** -- acPMSS7RxOctets table entry -- **************************************** acPMSS7RxOctetsEntry OBJECT-TYPE SYNTAX AcPMSS7RxOctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxOctetsLink,acPMSS7RxOctetsInterval} ::= {acPMSS7RxOctetsTable 1} -- **************************************** -- acPMSS7RxOctets TABLE -- **************************************** AcPMSS7RxOctetsEntry ::= SEQUENCE { acPMSS7RxOctetsLink Unsigned32, acPMSS7RxOctetsInterval Unsigned32, acPMSS7RxOctetsVal Counter32, acPMSS7RxOctetsTotal Integer32 } acPMSS7RxOctetsLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7RxOctetsEntry 1} acPMSS7RxOctetsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxOctetsEntry 2} acPMSS7RxOctetsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxOctetsEntry 3} acPMSS7RxOctetsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxOctetsEntry 4} -- **************************************** -- acPMSS7MTP2NoAckRx table declaration -- **************************************** acPMSS7MTP2NoAckRxTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2NoAckRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9" ::= {acPMSS7Links 11} -- **************************************** -- acPMSS7MTP2NoAckRx table entry -- **************************************** acPMSS7MTP2NoAckRxEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2NoAckRxEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2NoAckRxLink,acPMSS7MTP2NoAckRxInterval} ::= {acPMSS7MTP2NoAckRxTable 1} -- **************************************** -- acPMSS7MTP2NoAckRx TABLE -- **************************************** AcPMSS7MTP2NoAckRxEntry ::= SEQUENCE { acPMSS7MTP2NoAckRxLink Unsigned32, acPMSS7MTP2NoAckRxInterval Unsigned32, acPMSS7MTP2NoAckRxVal Counter32, acPMSS7MTP2NoAckRxTotal Integer32 } acPMSS7MTP2NoAckRxLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2NoAckRxEntry 1} acPMSS7MTP2NoAckRxInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2NoAckRxEntry 2} acPMSS7MTP2NoAckRxVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2NoAckRxEntry 3} acPMSS7MTP2NoAckRxTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2NoAckRxEntry 4} -- **************************************** -- acPMSS7DiscMSU table declaration -- **************************************** acPMSS7DiscMSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7DiscMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10" ::= {acPMSS7Links 12} -- **************************************** -- acPMSS7DiscMSU table entry -- **************************************** acPMSS7DiscMSUEntry OBJECT-TYPE SYNTAX AcPMSS7DiscMSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7DiscMSULink,acPMSS7DiscMSUInterval} ::= {acPMSS7DiscMSUTable 1} -- **************************************** -- acPMSS7DiscMSU TABLE -- **************************************** AcPMSS7DiscMSUEntry ::= SEQUENCE { acPMSS7DiscMSULink Unsigned32, acPMSS7DiscMSUInterval Unsigned32, acPMSS7DiscMSUVal Counter32, acPMSS7DiscMSUTotal Integer32 } acPMSS7DiscMSULink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7DiscMSUEntry 1} acPMSS7DiscMSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7DiscMSUEntry 2} acPMSS7DiscMSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7DiscMSUEntry 3} acPMSS7DiscMSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7DiscMSUEntry 4} -- **************************************** -- acPMSS7InService table declaration -- **************************************** acPMSS7InServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7InServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1" ::= {acPMSS7Links 13} -- **************************************** -- acPMSS7InService table entry -- **************************************** acPMSS7InServiceEntry OBJECT-TYPE SYNTAX AcPMSS7InServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7InServiceLink,acPMSS7InServiceInterval} ::= {acPMSS7InServiceTable 1} -- **************************************** -- acPMSS7InService TABLE -- **************************************** AcPMSS7InServiceEntry ::= SEQUENCE { acPMSS7InServiceLink Unsigned32, acPMSS7InServiceInterval Unsigned32, acPMSS7InServiceVal Gauge32, acPMSS7InServiceTimeAboveHighThreshold Integer32, acPMSS7InServiceTimeBetweenThresholds Integer32 } acPMSS7InServiceLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7InServiceEntry 1} acPMSS7InServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7InServiceEntry 2} acPMSS7InServiceVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7InServiceEntry 3} acPMSS7InServiceTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'In Service'." ::= {acPMSS7InServiceEntry 4} acPMSS7InServiceTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'In Service'." ::= {acPMSS7InServiceEntry 5} -- **************************************** -- acPMSS7OutOfService table declaration -- **************************************** acPMSS7OutOfServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7OutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1" ::= {acPMSS7Links 14} -- **************************************** -- acPMSS7OutOfService table entry -- **************************************** acPMSS7OutOfServiceEntry OBJECT-TYPE SYNTAX AcPMSS7OutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7OutOfServiceLink,acPMSS7OutOfServiceInterval} ::= {acPMSS7OutOfServiceTable 1} -- **************************************** -- acPMSS7OutOfService TABLE -- **************************************** AcPMSS7OutOfServiceEntry ::= SEQUENCE { acPMSS7OutOfServiceLink Unsigned32, acPMSS7OutOfServiceInterval Unsigned32, acPMSS7OutOfServiceVal Gauge32, acPMSS7OutOfServiceTimeAboveHighThreshold Integer32, acPMSS7OutOfServiceTimeBetweenThresholds Integer32 } acPMSS7OutOfServiceLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7OutOfServiceEntry 1} acPMSS7OutOfServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7OutOfServiceEntry 2} acPMSS7OutOfServiceVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7OutOfServiceEntry 3} acPMSS7OutOfServiceTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'." ::= {acPMSS7OutOfServiceEntry 4} acPMSS7OutOfServiceTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'." ::= {acPMSS7OutOfServiceEntry 5} acPMSS7LinkSets OBJECT IDENTIFIER ::= {acPMSS7Data 41} -- **************************************** -- acPMSS7SN0LSOutOfService table declaration -- **************************************** acPMSS7SN0LSOutOfServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7SN0LSOutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2" ::= {acPMSS7LinkSets 1} -- **************************************** -- acPMSS7SN0LSOutOfService table entry -- **************************************** acPMSS7SN0LSOutOfServiceEntry OBJECT-TYPE SYNTAX AcPMSS7SN0LSOutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7SN0LSOutOfServiceLinkSet,acPMSS7SN0LSOutOfServiceInterval} ::= {acPMSS7SN0LSOutOfServiceTable 1} -- **************************************** -- acPMSS7SN0LSOutOfService TABLE -- **************************************** AcPMSS7SN0LSOutOfServiceEntry ::= SEQUENCE { acPMSS7SN0LSOutOfServiceLinkSet Unsigned32, acPMSS7SN0LSOutOfServiceInterval Unsigned32, acPMSS7SN0LSOutOfServiceVal Gauge32, acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold Integer32, acPMSS7SN0LSOutOfServiceTimeBetweenThresholds Integer32 } acPMSS7SN0LSOutOfServiceLinkSet OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link Set number. 0 is the first link." ::= {acPMSS7SN0LSOutOfServiceEntry 1} acPMSS7SN0LSOutOfServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7SN0LSOutOfServiceEntry 2} acPMSS7SN0LSOutOfServiceVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7SN0LSOutOfServiceEntry 3} acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'." ::= {acPMSS7SN0LSOutOfServiceEntry 4} acPMSS7SN0LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'." ::= {acPMSS7SN0LSOutOfServiceEntry 5} -- **************************************** -- acPMSS7SN1LSOutOfService table declaration -- **************************************** acPMSS7SN1LSOutOfServiceTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7SN1LSOutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2" ::= {acPMSS7LinkSets 2} -- **************************************** -- acPMSS7SN1LSOutOfService table entry -- **************************************** acPMSS7SN1LSOutOfServiceEntry OBJECT-TYPE SYNTAX AcPMSS7SN1LSOutOfServiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7SN1LSOutOfServiceLinkSet,acPMSS7SN1LSOutOfServiceInterval} ::= {acPMSS7SN1LSOutOfServiceTable 1} -- **************************************** -- acPMSS7SN1LSOutOfService TABLE -- **************************************** AcPMSS7SN1LSOutOfServiceEntry ::= SEQUENCE { acPMSS7SN1LSOutOfServiceLinkSet Unsigned32, acPMSS7SN1LSOutOfServiceInterval Unsigned32, acPMSS7SN1LSOutOfServiceVal Gauge32, acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold Integer32, acPMSS7SN1LSOutOfServiceTimeBetweenThresholds Integer32 } acPMSS7SN1LSOutOfServiceLinkSet OBJECT-TYPE SYNTAX Unsigned32 (0..31) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link Set number. 0 is the first link." ::= {acPMSS7SN1LSOutOfServiceEntry 1} acPMSS7SN1LSOutOfServiceInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7SN1LSOutOfServiceEntry 2} acPMSS7SN1LSOutOfServiceVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7SN1LSOutOfServiceEntry 3} acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold. In this case - 'Out Of Service'." ::= {acPMSS7SN1LSOutOfServiceEntry 4} acPMSS7SN1LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds. In this case - not 'Out of Service'." ::= {acPMSS7SN1LSOutOfServiceEntry 5} acPMSS7SignalingNodes OBJECT IDENTIFIER ::= {acPMSS7Data 51} -- **************************************** -- acPMSS7TxMTP3Octets table declaration -- **************************************** acPMSS7TxMTP3OctetsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxMTP3OctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted MTP3 octets per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 1} -- **************************************** -- acPMSS7TxMTP3Octets table entry -- **************************************** acPMSS7TxMTP3OctetsEntry OBJECT-TYPE SYNTAX AcPMSS7TxMTP3OctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxMTP3OctetsSN,acPMSS7TxMTP3OctetsInterval} ::= {acPMSS7TxMTP3OctetsTable 1} -- **************************************** -- acPMSS7TxMTP3Octets TABLE -- **************************************** AcPMSS7TxMTP3OctetsEntry ::= SEQUENCE { acPMSS7TxMTP3OctetsSN Unsigned32, acPMSS7TxMTP3OctetsInterval Unsigned32, acPMSS7TxMTP3OctetsVal Counter32, acPMSS7TxMTP3OctetsTotal Integer32 } acPMSS7TxMTP3OctetsSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7TxMTP3OctetsEntry 1} acPMSS7TxMTP3OctetsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxMTP3OctetsEntry 2} acPMSS7TxMTP3OctetsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxMTP3OctetsEntry 3} acPMSS7TxMTP3OctetsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxMTP3OctetsEntry 4} -- **************************************** -- acPMSS7RxMTP3Octets table declaration -- **************************************** acPMSS7RxMTP3OctetsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxMTP3OctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received MTP3 octets per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 2} -- **************************************** -- acPMSS7RxMTP3Octets table entry -- **************************************** acPMSS7RxMTP3OctetsEntry OBJECT-TYPE SYNTAX AcPMSS7RxMTP3OctetsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxMTP3OctetsSN,acPMSS7RxMTP3OctetsInterval} ::= {acPMSS7RxMTP3OctetsTable 1} -- **************************************** -- acPMSS7RxMTP3Octets TABLE -- **************************************** AcPMSS7RxMTP3OctetsEntry ::= SEQUENCE { acPMSS7RxMTP3OctetsSN Unsigned32, acPMSS7RxMTP3OctetsInterval Unsigned32, acPMSS7RxMTP3OctetsVal Counter32, acPMSS7RxMTP3OctetsTotal Integer32 } acPMSS7RxMTP3OctetsSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7RxMTP3OctetsEntry 1} acPMSS7RxMTP3OctetsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxMTP3OctetsEntry 2} acPMSS7RxMTP3OctetsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxMTP3OctetsEntry 3} acPMSS7RxMTP3OctetsTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxMTP3OctetsEntry 4} -- **************************************** -- acPMSS7TxMTP3MSU table declaration -- **************************************** acPMSS7TxMTP3MSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxMTP3MSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted MTP3 MSU's per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 3} -- **************************************** -- acPMSS7TxMTP3MSU table entry -- **************************************** acPMSS7TxMTP3MSUEntry OBJECT-TYPE SYNTAX AcPMSS7TxMTP3MSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxMTP3MSUSN,acPMSS7TxMTP3MSUInterval} ::= {acPMSS7TxMTP3MSUTable 1} -- **************************************** -- acPMSS7TxMTP3MSU TABLE -- **************************************** AcPMSS7TxMTP3MSUEntry ::= SEQUENCE { acPMSS7TxMTP3MSUSN Unsigned32, acPMSS7TxMTP3MSUInterval Unsigned32, acPMSS7TxMTP3MSUVal Counter32, acPMSS7TxMTP3MSUTotal Integer32 } acPMSS7TxMTP3MSUSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7TxMTP3MSUEntry 1} acPMSS7TxMTP3MSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxMTP3MSUEntry 2} acPMSS7TxMTP3MSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxMTP3MSUEntry 3} acPMSS7TxMTP3MSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxMTP3MSUEntry 4} -- **************************************** -- acPMSS7RxMTP3MSU table declaration -- **************************************** acPMSS7RxMTP3MSUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxMTP3MSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received MTP3 MSU's per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 4} -- **************************************** -- acPMSS7RxMTP3MSU table entry -- **************************************** acPMSS7RxMTP3MSUEntry OBJECT-TYPE SYNTAX AcPMSS7RxMTP3MSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxMTP3MSUSN,acPMSS7RxMTP3MSUInterval} ::= {acPMSS7RxMTP3MSUTable 1} -- **************************************** -- acPMSS7RxMTP3MSU TABLE -- **************************************** AcPMSS7RxMTP3MSUEntry ::= SEQUENCE { acPMSS7RxMTP3MSUSN Unsigned32, acPMSS7RxMTP3MSUInterval Unsigned32, acPMSS7RxMTP3MSUVal Counter32, acPMSS7RxMTP3MSUTotal Integer32 } acPMSS7RxMTP3MSUSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7RxMTP3MSUEntry 1} acPMSS7RxMTP3MSUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxMTP3MSUEntry 2} acPMSS7RxMTP3MSUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxMTP3MSUEntry 3} acPMSS7RxMTP3MSUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxMTP3MSUEntry 4} -- **************************************** -- acPMSS7TxMTP3UPU table declaration -- **************************************** acPMSS7TxMTP3UPUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7TxMTP3UPUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 5} -- **************************************** -- acPMSS7TxMTP3UPU table entry -- **************************************** acPMSS7TxMTP3UPUEntry OBJECT-TYPE SYNTAX AcPMSS7TxMTP3UPUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7TxMTP3UPUSN,acPMSS7TxMTP3UPUInterval} ::= {acPMSS7TxMTP3UPUTable 1} -- **************************************** -- acPMSS7TxMTP3UPU TABLE -- **************************************** AcPMSS7TxMTP3UPUEntry ::= SEQUENCE { acPMSS7TxMTP3UPUSN Unsigned32, acPMSS7TxMTP3UPUInterval Unsigned32, acPMSS7TxMTP3UPUVal Counter32, acPMSS7TxMTP3UPUTotal Integer32 } acPMSS7TxMTP3UPUSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7TxMTP3UPUEntry 1} acPMSS7TxMTP3UPUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7TxMTP3UPUEntry 2} acPMSS7TxMTP3UPUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7TxMTP3UPUEntry 3} acPMSS7TxMTP3UPUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7TxMTP3UPUEntry 4} -- **************************************** -- acPMSS7RxMTP3UPU table declaration -- **************************************** acPMSS7RxMTP3UPUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxMTP3UPUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 6} -- **************************************** -- acPMSS7RxMTP3UPU table entry -- **************************************** acPMSS7RxMTP3UPUEntry OBJECT-TYPE SYNTAX AcPMSS7RxMTP3UPUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxMTP3UPUSN,acPMSS7RxMTP3UPUInterval} ::= {acPMSS7RxMTP3UPUTable 1} -- **************************************** -- acPMSS7RxMTP3UPU TABLE -- **************************************** AcPMSS7RxMTP3UPUEntry ::= SEQUENCE { acPMSS7RxMTP3UPUSN Unsigned32, acPMSS7RxMTP3UPUInterval Unsigned32, acPMSS7RxMTP3UPUVal Counter32, acPMSS7RxMTP3UPUTotal Integer32 } acPMSS7RxMTP3UPUSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7RxMTP3UPUEntry 1} acPMSS7RxMTP3UPUInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxMTP3UPUEntry 2} acPMSS7RxMTP3UPUVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxMTP3UPUEntry 3} acPMSS7RxMTP3UPUTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxMTP3UPUEntry 4} -- **************************************** -- acPMSS7MTP3MSUDiscarded table declaration -- **************************************** acPMSS7MTP3MSUDiscardedTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of discarded MTP3 MSU's per SS7 MTP3 node" ::= {acPMSS7SignalingNodes 7} -- **************************************** -- acPMSS7MTP3MSUDiscarded table entry -- **************************************** acPMSS7MTP3MSUDiscardedEntry OBJECT-TYPE SYNTAX AcPMSS7MTP3MSUDiscardedEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP3MSUDiscardedSN,acPMSS7MTP3MSUDiscardedInterval} ::= {acPMSS7MTP3MSUDiscardedTable 1} -- **************************************** -- acPMSS7MTP3MSUDiscarded TABLE -- **************************************** AcPMSS7MTP3MSUDiscardedEntry ::= SEQUENCE { acPMSS7MTP3MSUDiscardedSN Unsigned32, acPMSS7MTP3MSUDiscardedInterval Unsigned32, acPMSS7MTP3MSUDiscardedVal Counter32, acPMSS7MTP3MSUDiscardedTotal Integer32 } acPMSS7MTP3MSUDiscardedSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7MTP3MSUDiscardedEntry 1} acPMSS7MTP3MSUDiscardedInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP3MSUDiscardedEntry 2} acPMSS7MTP3MSUDiscardedVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP3MSUDiscardedEntry 3} acPMSS7MTP3MSUDiscardedTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP3MSUDiscardedEntry 4} -- **************************************** -- acPMSS7MTP3MSUDiscardedRtDataErr table declaration -- **************************************** acPMSS7MTP3MSUDiscardedRtDataErrTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedRtDataErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5" ::= {acPMSS7SignalingNodes 8} -- **************************************** -- acPMSS7MTP3MSUDiscardedRtDataErr table entry -- **************************************** acPMSS7MTP3MSUDiscardedRtDataErrEntry OBJECT-TYPE SYNTAX AcPMSS7MTP3MSUDiscardedRtDataErrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP3MSUDiscardedRtDataErrSN,acPMSS7MTP3MSUDiscardedRtDataErrInterval} ::= {acPMSS7MTP3MSUDiscardedRtDataErrTable 1} -- **************************************** -- acPMSS7MTP3MSUDiscardedRtDataErr TABLE -- **************************************** AcPMSS7MTP3MSUDiscardedRtDataErrEntry ::= SEQUENCE { acPMSS7MTP3MSUDiscardedRtDataErrSN Unsigned32, acPMSS7MTP3MSUDiscardedRtDataErrInterval Unsigned32, acPMSS7MTP3MSUDiscardedRtDataErrVal Counter32, acPMSS7MTP3MSUDiscardedRtDataErrTotal Integer32 } acPMSS7MTP3MSUDiscardedRtDataErrSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 1} acPMSS7MTP3MSUDiscardedRtDataErrInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 2} acPMSS7MTP3MSUDiscardedRtDataErrVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 3} acPMSS7MTP3MSUDiscardedRtDataErrTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 4} -- **************************************** -- acPMSS7RxMTP3TFCMsg table declaration -- **************************************** acPMSS7RxMTP3TFCMsgTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7RxMTP3TFCMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP3 TFC messages received per SS7 MTP3 node " ::= {acPMSS7SignalingNodes 9} -- **************************************** -- acPMSS7RxMTP3TFCMsg table entry -- **************************************** acPMSS7RxMTP3TFCMsgEntry OBJECT-TYPE SYNTAX AcPMSS7RxMTP3TFCMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7RxMTP3TFCMsgSN,acPMSS7RxMTP3TFCMsgInterval} ::= {acPMSS7RxMTP3TFCMsgTable 1} -- **************************************** -- acPMSS7RxMTP3TFCMsg TABLE -- **************************************** AcPMSS7RxMTP3TFCMsgEntry ::= SEQUENCE { acPMSS7RxMTP3TFCMsgSN Unsigned32, acPMSS7RxMTP3TFCMsgInterval Unsigned32, acPMSS7RxMTP3TFCMsgVal Counter32, acPMSS7RxMTP3TFCMsgTotal Integer32 } acPMSS7RxMTP3TFCMsgSN OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "SN number. 0 is the first SN." ::= {acPMSS7RxMTP3TFCMsgEntry 1} acPMSS7RxMTP3TFCMsgInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7RxMTP3TFCMsgEntry 2} acPMSS7RxMTP3TFCMsgVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7RxMTP3TFCMsgEntry 3} acPMSS7RxMTP3TFCMsgTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7RxMTP3TFCMsgEntry 4} acPMSS7MPT2Timers OBJECT IDENTIFIER ::= {acPMSS7Data 61} -- **************************************** -- acPMSS7MTP2T1Expiry table declaration -- **************************************** acPMSS7MTP2T1ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T1ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T1 expiry per SS7 link" ::= {acPMSS7MPT2Timers 1} -- **************************************** -- acPMSS7MTP2T1Expiry table entry -- **************************************** acPMSS7MTP2T1ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T1ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T1ExpiryLink,acPMSS7MTP2T1ExpiryInterval} ::= {acPMSS7MTP2T1ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T1Expiry TABLE -- **************************************** AcPMSS7MTP2T1ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T1ExpiryLink Unsigned32, acPMSS7MTP2T1ExpiryInterval Unsigned32, acPMSS7MTP2T1ExpiryVal Counter32, acPMSS7MTP2T1ExpiryTotal Integer32 } acPMSS7MTP2T1ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T1ExpiryEntry 1} acPMSS7MTP2T1ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T1ExpiryEntry 2} acPMSS7MTP2T1ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T1ExpiryEntry 3} acPMSS7MTP2T1ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T1ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T2Expiry table declaration -- **************************************** acPMSS7MTP2T2ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T2ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T2 expiry per SS7 link" ::= {acPMSS7MPT2Timers 2} -- **************************************** -- acPMSS7MTP2T2Expiry table entry -- **************************************** acPMSS7MTP2T2ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T2ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T2ExpiryLink,acPMSS7MTP2T2ExpiryInterval} ::= {acPMSS7MTP2T2ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T2Expiry TABLE -- **************************************** AcPMSS7MTP2T2ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T2ExpiryLink Unsigned32, acPMSS7MTP2T2ExpiryInterval Unsigned32, acPMSS7MTP2T2ExpiryVal Counter32, acPMSS7MTP2T2ExpiryTotal Integer32 } acPMSS7MTP2T2ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T2ExpiryEntry 1} acPMSS7MTP2T2ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T2ExpiryEntry 2} acPMSS7MTP2T2ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T2ExpiryEntry 3} acPMSS7MTP2T2ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T2ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T3Expiry table declaration -- **************************************** acPMSS7MTP2T3ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T3ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T3 expiry per SS7 link" ::= {acPMSS7MPT2Timers 3} -- **************************************** -- acPMSS7MTP2T3Expiry table entry -- **************************************** acPMSS7MTP2T3ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T3ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T3ExpiryLink,acPMSS7MTP2T3ExpiryInterval} ::= {acPMSS7MTP2T3ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T3Expiry TABLE -- **************************************** AcPMSS7MTP2T3ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T3ExpiryLink Unsigned32, acPMSS7MTP2T3ExpiryInterval Unsigned32, acPMSS7MTP2T3ExpiryVal Counter32, acPMSS7MTP2T3ExpiryTotal Integer32 } acPMSS7MTP2T3ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T3ExpiryEntry 1} acPMSS7MTP2T3ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T3ExpiryEntry 2} acPMSS7MTP2T3ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T3ExpiryEntry 3} acPMSS7MTP2T3ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T3ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T4Expiry table declaration -- **************************************** acPMSS7MTP2T4ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T4ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T4 expiry per SS7 link" ::= {acPMSS7MPT2Timers 4} -- **************************************** -- acPMSS7MTP2T4Expiry table entry -- **************************************** acPMSS7MTP2T4ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T4ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T4ExpiryLink,acPMSS7MTP2T4ExpiryInterval} ::= {acPMSS7MTP2T4ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T4Expiry TABLE -- **************************************** AcPMSS7MTP2T4ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T4ExpiryLink Unsigned32, acPMSS7MTP2T4ExpiryInterval Unsigned32, acPMSS7MTP2T4ExpiryVal Counter32, acPMSS7MTP2T4ExpiryTotal Integer32 } acPMSS7MTP2T4ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T4ExpiryEntry 1} acPMSS7MTP2T4ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T4ExpiryEntry 2} acPMSS7MTP2T4ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T4ExpiryEntry 3} acPMSS7MTP2T4ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T4ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T5Expiry table declaration -- **************************************** acPMSS7MTP2T5ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T5ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T5 expiry per SS7 link" ::= {acPMSS7MPT2Timers 5} -- **************************************** -- acPMSS7MTP2T5Expiry table entry -- **************************************** acPMSS7MTP2T5ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T5ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T5ExpiryLink,acPMSS7MTP2T5ExpiryInterval} ::= {acPMSS7MTP2T5ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T5Expiry TABLE -- **************************************** AcPMSS7MTP2T5ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T5ExpiryLink Unsigned32, acPMSS7MTP2T5ExpiryInterval Unsigned32, acPMSS7MTP2T5ExpiryVal Counter32, acPMSS7MTP2T5ExpiryTotal Integer32 } acPMSS7MTP2T5ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T5ExpiryEntry 1} acPMSS7MTP2T5ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T5ExpiryEntry 2} acPMSS7MTP2T5ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T5ExpiryEntry 3} acPMSS7MTP2T5ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T5ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T6Expiry table declaration -- **************************************** acPMSS7MTP2T6ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T6ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T6 expiry per SS7 link" ::= {acPMSS7MPT2Timers 6} -- **************************************** -- acPMSS7MTP2T6Expiry table entry -- **************************************** acPMSS7MTP2T6ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T6ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T6ExpiryLink,acPMSS7MTP2T6ExpiryInterval} ::= {acPMSS7MTP2T6ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T6Expiry TABLE -- **************************************** AcPMSS7MTP2T6ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T6ExpiryLink Unsigned32, acPMSS7MTP2T6ExpiryInterval Unsigned32, acPMSS7MTP2T6ExpiryVal Counter32, acPMSS7MTP2T6ExpiryTotal Integer32 } acPMSS7MTP2T6ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T6ExpiryEntry 1} acPMSS7MTP2T6ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T6ExpiryEntry 2} acPMSS7MTP2T6ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T6ExpiryEntry 3} acPMSS7MTP2T6ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T6ExpiryEntry 4} -- **************************************** -- acPMSS7MTP2T7Expiry table declaration -- **************************************** acPMSS7MTP2T7ExpiryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSS7MTP2T7ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of MTP2 T7 expiry per SS7 link" ::= {acPMSS7MPT2Timers 7} -- **************************************** -- acPMSS7MTP2T7Expiry table entry -- **************************************** acPMSS7MTP2T7ExpiryEntry OBJECT-TYPE SYNTAX AcPMSS7MTP2T7ExpiryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSS7MTP2T7ExpiryLink,acPMSS7MTP2T7ExpiryInterval} ::= {acPMSS7MTP2T7ExpiryTable 1} -- **************************************** -- acPMSS7MTP2T7Expiry TABLE -- **************************************** AcPMSS7MTP2T7ExpiryEntry ::= SEQUENCE { acPMSS7MTP2T7ExpiryLink Unsigned32, acPMSS7MTP2T7ExpiryInterval Unsigned32, acPMSS7MTP2T7ExpiryVal Counter32, acPMSS7MTP2T7ExpiryTotal Integer32 } acPMSS7MTP2T7ExpiryLink OBJECT-TYPE SYNTAX Unsigned32 (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Link number. 0 is the first link." ::= {acPMSS7MTP2T7ExpiryEntry 1} acPMSS7MTP2T7ExpiryInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSS7MTP2T7ExpiryEntry 2} acPMSS7MTP2T7ExpiryVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSS7MTP2T7ExpiryEntry 3} acPMSS7MTP2T7ExpiryTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSS7MTP2T7ExpiryEntry 4} END