AC-PM-Control-MIB DEFINITIONS ::= BEGIN IMPORTS Counter32, Gauge32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TAddress, DisplayString, DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC IpAddress FROM RFC1155-SMI Unsigned32, Integer32, enterprises FROM SNMPv2-SMI SnmpAdminString FROM SNMP-FRAMEWORK-MIB audioCodes, acRegistrations, acGeneric, acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB; acPMControl MODULE-IDENTITY LAST-UPDATED "200908250451Z" --Tuesday, August 25, 2009 ORGANIZATION "AudioCodes Ltd" CONTACT-INFO "Postal: Support AudioCodes LTD 1 Hayarden Street Airport City Lod, ISRAEL 70151 Tel: 972-3-9764000 Fax: 972-3-9764040 Email: support@audiocodes.com Web: www.audiocodes.com" DESCRIPTION "The AC-PM-Control MIB offers performance monitoring For the Control related elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-Control MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded." ::= {acPerformance 8} acPMControlConfiguration OBJECT IDENTIFIER ::= {acPMControl 1} acPMControlConfigurationPeriodLength OBJECT-TYPE SYNTAX Unsigned32 (0..894780) MAX-ACCESS read-write STATUS current DESCRIPTION "Length of monitoring intervals for entire MIB. Time is in minutes. Access: Instant." ::= {acPMControlConfiguration 1} acPMControlConfigurationResetTotalCounters OBJECT-TYPE SYNTAX INTEGER { resetCountersDone(1) , resetTotalCounters(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Total-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2). Access: Instant." ::= {acPMControlConfiguration 2} acPMCPConnectionAttributes OBJECT IDENTIFIER ::= {acPMControlConfiguration 32} acPMCPConnectionAttributesLifetimeHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 1} acPMCPConnectionAttributesLifetimeLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 2} acPMCPConnectionAttributesStateHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 3} acPMCPConnectionAttributesStateLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 4} acPMCPConnectionAttributesCommandCounterHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 5} acPMCPConnectionAttributesCommandCounterLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 6} acPMCPConnectionAttributesRetransmissionCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 7} acPMCPConnectionAttributesRetransmissionCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 8} acPMCPConnectionAttributesActiveContextCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 9} acPMCPConnectionAttributesActiveContextCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 10} acPMCPConnectionAttributesCommandSuccessCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 11} acPMCPConnectionAttributesCommandSuccessCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 12} acPMCPConnectionAttributesCommandFailureCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 13} acPMCPConnectionAttributesCommandFailureCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 14} acPMCPConnectionAttributesCommandProcessTimeHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 15} acPMCPConnectionAttributesCommandProcessTimeLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 16} acPMCPConnectionAttributesTransactionProcessTimerHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMCPConnectionAttributes 17} acPMCPConnectionAttributesTransactionProcessTimerLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMCPConnectionAttributes 18} acPMMegacoAttributes OBJECT IDENTIFIER ::= {acPMControlConfiguration 33} acPMMegacoAttributesServiceChangeCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "High threshold. Access: Instant." ::= {acPMMegacoAttributes 1} acPMMegacoAttributesServiceChangeCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMMegacoAttributes 2} acPMMegacoAttributesCmdSuccessCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "High threshold. Access: Instant." ::= {acPMMegacoAttributes 3} acPMMegacoAttributesCmdSuccessCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Low threshold. Access: Instant." ::= {acPMMegacoAttributes 4} acPMMegacoAttributesCmdFailureCountHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "High threshold. Access: Instant." ::= {acPMMegacoAttributes 5} acPMMegacoAttributesCmdFailureCountLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Low threshold. Access: Instant." ::= {acPMMegacoAttributes 6} acPMSipAttributes OBJECT IDENTIFIER ::= {acPMControlConfiguration 34} acPMSipAttributesCallDurationHighThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMSipAttributes 1} acPMSipAttributesCallDurationLowThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-write STATUS current DESCRIPTION "Low threshold. Access: Instant." ::= {acPMSipAttributes 2} acPMControlData OBJECT IDENTIFIER ::= {acPMControl 2} acPMControlDataAcPMControlTimeFromStartOfInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The time in seconds since the start of the current interval. MIB specific." ::= {acPMControlData 1} acPMCPConnection OBJECT IDENTIFIER ::= {acPMControlData 31} -- **************************************** -- acPMCPConnectionLifetime table declaration -- **************************************** acPMCPConnectionLifetimeTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPConnectionLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Connection lifetime in seconds." ::= {acPMCPConnection 1} -- **************************************** -- acPMCPConnectionLifetime table entry -- **************************************** acPMCPConnectionLifetimeEntry OBJECT-TYPE SYNTAX AcPMCPConnectionLifetimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPConnectionLifetimeInterval} ::= {acPMCPConnectionLifetimeTable 1} -- **************************************** -- acPMCPConnectionLifetime TABLE -- **************************************** AcPMCPConnectionLifetimeEntry ::= SEQUENCE { acPMCPConnectionLifetimeInterval Unsigned32, acPMCPConnectionLifetimeVal Gauge32, acPMCPConnectionLifetimeAverage Integer32, acPMCPConnectionLifetimeMax Integer32, acPMCPConnectionLifetimeMin Integer32, acPMCPConnectionLifetimeVolume Counter32, acPMCPConnectionLifetimeTimeBelowLowThreshold Integer32, acPMCPConnectionLifetimeTimeBetweenThresholds Integer32, acPMCPConnectionLifetimeTimeAboveHighThreshold Integer32, acPMCPConnectionLifetimeFullDayAverage Integer32, acPMCPConnectionLifetimeTotal Integer32 } acPMCPConnectionLifetimeInterval OBJECT-TYPE SYNTAX Unsigned32 (0..4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last 3 - Two before last 4 - Three before last." ::= {acPMCPConnectionLifetimeEntry 1} acPMCPConnectionLifetimeVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPConnectionLifetimeEntry 2} acPMCPConnectionLifetimeAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMCPConnectionLifetimeEntry 3} acPMCPConnectionLifetimeMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMCPConnectionLifetimeEntry 4} acPMCPConnectionLifetimeMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMCPConnectionLifetimeEntry 5} acPMCPConnectionLifetimeVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMCPConnectionLifetimeEntry 6} acPMCPConnectionLifetimeTimeBelowLowThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is below what was determined as the low threshold." ::= {acPMCPConnectionLifetimeEntry 7} acPMCPConnectionLifetimeTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold." ::= {acPMCPConnectionLifetimeEntry 8} acPMCPConnectionLifetimeTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMCPConnectionLifetimeEntry 9} acPMCPConnectionLifetimeFullDayAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The average of full 24 hours." ::= {acPMCPConnectionLifetimeEntry 10} acPMCPConnectionLifetimeTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPConnectionLifetimeEntry 11} -- **************************************** -- acPMCPConnectionState table declaration -- **************************************** acPMCPConnectionStateTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPConnectionStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MGC connection activity indicator." ::= {acPMCPConnection 2} -- **************************************** -- acPMCPConnectionState table entry -- **************************************** acPMCPConnectionStateEntry OBJECT-TYPE SYNTAX AcPMCPConnectionStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPConnectionStateInterval} ::= {acPMCPConnectionStateTable 1} -- **************************************** -- acPMCPConnectionState TABLE -- **************************************** AcPMCPConnectionStateEntry ::= SEQUENCE { acPMCPConnectionStateInterval Unsigned32, acPMCPConnectionStateChanges Gauge32, acPMCPConnectionStateActiveTime Integer32 } acPMCPConnectionStateInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPConnectionStateEntry 1} acPMCPConnectionStateChanges OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMCPConnectionStateEntry 2} acPMCPConnectionStateActiveTime OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMCPConnectionStateEntry 3} -- **************************************** -- acPMCPCommandCounter table declaration -- **************************************** acPMCPCommandCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCommandCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MGC command/response counters. Index: 0=sent commands, 1=received commands" ::= {acPMCPConnection 3} -- **************************************** -- acPMCPCommandCounter table entry -- **************************************** acPMCPCommandCounterEntry OBJECT-TYPE SYNTAX AcPMCPCommandCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPCommandCounterDirection,acPMCPCommandCounterInterval} ::= {acPMCPCommandCounterTable 1} -- **************************************** -- acPMCPCommandCounter TABLE -- **************************************** AcPMCPCommandCounterEntry ::= SEQUENCE { acPMCPCommandCounterDirection INTEGER, acPMCPCommandCounterInterval Unsigned32, acPMCPCommandCounterVal Counter32, acPMCPCommandCounterTotal Integer32 } acPMCPCommandCounterDirection OBJECT-TYPE SYNTAX INTEGER { tx(0) , rx(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index. 0 - transmit 1 - receive." ::= {acPMCPCommandCounterEntry 1} acPMCPCommandCounterInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCommandCounterEntry 2} acPMCPCommandCounterVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPCommandCounterEntry 3} acPMCPCommandCounterTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPCommandCounterEntry 4} -- **************************************** -- acPMCPRetransmissionCount table declaration -- **************************************** acPMCPRetransmissionCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPRetransmissionCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of transaction retransmissions. The first direction (tx(0)) counts the transactions sent from the board, while the second direction (rx(1)) counts the incoming retransmissions." ::= {acPMCPConnection 4} -- **************************************** -- acPMCPRetransmissionCount table entry -- **************************************** acPMCPRetransmissionCountEntry OBJECT-TYPE SYNTAX AcPMCPRetransmissionCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPRetransmissionCountDirection,acPMCPRetransmissionCountInterval} ::= {acPMCPRetransmissionCountTable 1} -- **************************************** -- acPMCPRetransmissionCount TABLE -- **************************************** AcPMCPRetransmissionCountEntry ::= SEQUENCE { acPMCPRetransmissionCountDirection INTEGER, acPMCPRetransmissionCountInterval Unsigned32, acPMCPRetransmissionCountVal Gauge32, acPMCPRetransmissionCountTotal Integer32 } acPMCPRetransmissionCountDirection OBJECT-TYPE SYNTAX INTEGER { tx(0) , rx(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index. 0 - transmit 1 - receive." ::= {acPMCPRetransmissionCountEntry 1} acPMCPRetransmissionCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPRetransmissionCountEntry 2} acPMCPRetransmissionCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPRetransmissionCountEntry 3} acPMCPRetransmissionCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPRetransmissionCountEntry 4} -- **************************************** -- acPMActiveContextCount table declaration -- **************************************** acPMActiveContextCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMActiveContextCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of active contexts" ::= {acPMCPConnection 5} -- **************************************** -- acPMActiveContextCount table entry -- **************************************** acPMActiveContextCountEntry OBJECT-TYPE SYNTAX AcPMActiveContextCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMActiveContextCountInterval} ::= {acPMActiveContextCountTable 1} -- **************************************** -- acPMActiveContextCount TABLE -- **************************************** AcPMActiveContextCountEntry ::= SEQUENCE { acPMActiveContextCountInterval Unsigned32, acPMActiveContextCountVal Gauge32, acPMActiveContextCountAverage Integer32, acPMActiveContextCountMax Integer32, acPMActiveContextCountMin Integer32, acPMActiveContextCountVolume Counter32, acPMActiveContextCountTimeBelowLowThreshold Integer32, acPMActiveContextCountTimeBetweenThresholds Integer32, acPMActiveContextCountTimeAboveHighThreshold Integer32, acPMActiveContextCountFullDayAverage Integer32, acPMActiveContextCountTotal Integer32 } acPMActiveContextCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMActiveContextCountEntry 1} acPMActiveContextCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMActiveContextCountEntry 2} acPMActiveContextCountAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMActiveContextCountEntry 3} acPMActiveContextCountMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMActiveContextCountEntry 4} acPMActiveContextCountMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMActiveContextCountEntry 5} acPMActiveContextCountVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMActiveContextCountEntry 6} acPMActiveContextCountTimeBelowLowThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is below what was determined as the low threshold." ::= {acPMActiveContextCountEntry 7} acPMActiveContextCountTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold." ::= {acPMActiveContextCountEntry 8} acPMActiveContextCountTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMActiveContextCountEntry 9} acPMActiveContextCountFullDayAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The average of full 24 hours." ::= {acPMActiveContextCountEntry 10} acPMActiveContextCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMActiveContextCountEntry 11} -- **************************************** -- acPMCPCommandSuccessCount table declaration -- **************************************** acPMCPCommandSuccessCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Number of successful commands, per command type. Index: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify" ::= {acPMCPConnection 6} -- **************************************** -- acPMCPCommandSuccessCount table entry -- **************************************** acPMCPCommandSuccessCountEntry OBJECT-TYPE SYNTAX AcPMCPCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX {acPMCPCommandSuccessCountCommandType,acPMCPCommandSuccessCountInterval} ::= {acPMCPCommandSuccessCountTable 1} -- **************************************** -- acPMCPCommandSuccessCount TABLE -- **************************************** AcPMCPCommandSuccessCountEntry ::= SEQUENCE { acPMCPCommandSuccessCountCommandType INTEGER, acPMCPCommandSuccessCountInterval Unsigned32, acPMCPCommandSuccessCountVal Gauge32, acPMCPCommandSuccessCountTotal Integer32 } acPMCPCommandSuccessCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Command type: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify." ::= {acPMCPCommandSuccessCountEntry 1} acPMCPCommandSuccessCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCommandSuccessCountEntry 2} acPMCPCommandSuccessCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Value of gauge or counter." ::= {acPMCPCommandSuccessCountEntry 3} acPMCPCommandSuccessCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Total since last reset." ::= {acPMCPCommandSuccessCountEntry 4} -- **************************************** -- acPMCPCommandFailureCount table declaration -- **************************************** acPMCPCommandFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCommandFailureCountEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Number of failing commands, per command type. Index: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify" ::= {acPMCPConnection 7} -- **************************************** -- acPMCPCommandFailureCount table entry -- **************************************** acPMCPCommandFailureCountEntry OBJECT-TYPE SYNTAX AcPMCPCommandFailureCountEntry MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "" INDEX {acPMCPCommandFailureCountCommandType,acPMCPCommandFailureCountInterval} ::= {acPMCPCommandFailureCountTable 1} -- **************************************** -- acPMCPCommandFailureCount TABLE -- **************************************** AcPMCPCommandFailureCountEntry ::= SEQUENCE { acPMCPCommandFailureCountCommandType INTEGER, acPMCPCommandFailureCountInterval Unsigned32, acPMCPCommandFailureCountVal Gauge32, acPMCPCommandFailureCountTotal Integer32 } acPMCPCommandFailureCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Command type: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify." ::= {acPMCPCommandFailureCountEntry 1} acPMCPCommandFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS obsolete DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCommandFailureCountEntry 2} acPMCPCommandFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Value of gauge or counter." ::= {acPMCPCommandFailureCountEntry 3} acPMCPCommandFailureCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPCommandFailureCountEntry 4} -- **************************************** -- acPMcpCmdProcessTime table declaration -- **************************************** acPMcpCmdProcessTimeTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMcpCmdProcessTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Processing time (in Microseconds), per command type." ::= {acPMCPConnection 8} -- **************************************** -- acPMcpCmdProcessTime table entry -- **************************************** acPMcpCmdProcessTimeEntry OBJECT-TYPE SYNTAX AcPMcpCmdProcessTimeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMcpCmdProcessTimeInterval} ::= {acPMcpCmdProcessTimeTable 1} -- **************************************** -- acPMcpCmdProcessTime TABLE -- **************************************** AcPMcpCmdProcessTimeEntry ::= SEQUENCE { acPMcpCmdProcessTimeInterval Unsigned32, acPMcpCmdProcessTimeVal Gauge32, acPMcpCmdProcessTimeAverage Integer32, acPMcpCmdProcessTimeMax Integer32, acPMcpCmdProcessTimeMin Integer32, acPMcpCmdProcessTimeVolume Counter32, acPMcpCmdProcessTimeTimeBelowLowThreshold Integer32, acPMcpCmdProcessTimeTimeBetweenThresholds Integer32, acPMcpCmdProcessTimeTimeAboveHighThreshold Integer32, acPMcpCmdProcessTimeFullDayAverage Integer32, acPMcpCmdProcessTimeTotal Integer32 } acPMcpCmdProcessTimeInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMcpCmdProcessTimeEntry 1} acPMcpCmdProcessTimeVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMcpCmdProcessTimeEntry 2} acPMcpCmdProcessTimeAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMcpCmdProcessTimeEntry 3} acPMcpCmdProcessTimeMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMcpCmdProcessTimeEntry 4} acPMcpCmdProcessTimeMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMcpCmdProcessTimeEntry 5} acPMcpCmdProcessTimeVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMcpCmdProcessTimeEntry 6} acPMcpCmdProcessTimeTimeBelowLowThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is below what was determined as the low threshold." ::= {acPMcpCmdProcessTimeEntry 7} acPMcpCmdProcessTimeTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold." ::= {acPMcpCmdProcessTimeEntry 8} acPMcpCmdProcessTimeTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMcpCmdProcessTimeEntry 9} acPMcpCmdProcessTimeFullDayAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The average of full 24 hours." ::= {acPMcpCmdProcessTimeEntry 10} acPMcpCmdProcessTimeTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMcpCmdProcessTimeEntry 11} -- **************************************** -- acPMcpTransactionProcessTimer table declaration -- **************************************** acPMcpTransactionProcessTimerTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMcpTransactionProcessTimerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Processing time (in Microseconds), For transaction request." ::= {acPMCPConnection 9} -- **************************************** -- acPMcpTransactionProcessTimer table entry -- **************************************** acPMcpTransactionProcessTimerEntry OBJECT-TYPE SYNTAX AcPMcpTransactionProcessTimerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMcpTransactionProcessTimerInterval} ::= {acPMcpTransactionProcessTimerTable 1} -- **************************************** -- acPMcpTransactionProcessTimer TABLE -- **************************************** AcPMcpTransactionProcessTimerEntry ::= SEQUENCE { acPMcpTransactionProcessTimerInterval Unsigned32, acPMcpTransactionProcessTimerVal Gauge32, acPMcpTransactionProcessTimerAverage Integer32, acPMcpTransactionProcessTimerMax Integer32, acPMcpTransactionProcessTimerMin Integer32, acPMcpTransactionProcessTimerVolume Counter32, acPMcpTransactionProcessTimerTimeBelowLowThreshold Integer32, acPMcpTransactionProcessTimerTimeBetweenThresholds Integer32, acPMcpTransactionProcessTimerTimeAboveHighThreshold Integer32, acPMcpTransactionProcessTimerFullDayAverage Integer32, acPMcpTransactionProcessTimerTotal Integer32 } acPMcpTransactionProcessTimerInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMcpTransactionProcessTimerEntry 1} acPMcpTransactionProcessTimerVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMcpTransactionProcessTimerEntry 2} acPMcpTransactionProcessTimerAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMcpTransactionProcessTimerEntry 3} acPMcpTransactionProcessTimerMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMcpTransactionProcessTimerEntry 4} acPMcpTransactionProcessTimerMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMcpTransactionProcessTimerEntry 5} acPMcpTransactionProcessTimerVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMcpTransactionProcessTimerEntry 6} acPMcpTransactionProcessTimerTimeBelowLowThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is below what was determined as the low threshold." ::= {acPMcpTransactionProcessTimerEntry 7} acPMcpTransactionProcessTimerTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold." ::= {acPMcpTransactionProcessTimerEntry 8} acPMcpTransactionProcessTimerTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMcpTransactionProcessTimerEntry 9} acPMcpTransactionProcessTimerFullDayAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The average of full 24 hours." ::= {acPMcpTransactionProcessTimerEntry 10} acPMcpTransactionProcessTimerTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMcpTransactionProcessTimerEntry 11} -- **************************************** -- acPMCPCallAttemptsPerSec table declaration -- **************************************** acPMCPCallAttemptsPerSecTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCallAttemptsPerSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of Call attempts (successful and unsuccessful) for second" ::= {acPMCPConnection 10} -- **************************************** -- acPMCPCallAttemptsPerSec table entry -- **************************************** acPMCPCallAttemptsPerSecEntry OBJECT-TYPE SYNTAX AcPMCPCallAttemptsPerSecEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPCallAttemptsPerSecInterval} ::= {acPMCPCallAttemptsPerSecTable 1} -- **************************************** -- acPMCPCallAttemptsPerSec TABLE -- **************************************** AcPMCPCallAttemptsPerSecEntry ::= SEQUENCE { acPMCPCallAttemptsPerSecInterval Unsigned32, acPMCPCallAttemptsPerSecVal Gauge32, acPMCPCallAttemptsPerSecAverage Integer32, acPMCPCallAttemptsPerSecMax Integer32, acPMCPCallAttemptsPerSecMin Integer32, acPMCPCallAttemptsPerSecVolume Counter32 } acPMCPCallAttemptsPerSecInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCallAttemptsPerSecEntry 1} acPMCPCallAttemptsPerSecVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPCallAttemptsPerSecEntry 2} acPMCPCallAttemptsPerSecAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMCPCallAttemptsPerSecEntry 3} acPMCPCallAttemptsPerSecMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMCPCallAttemptsPerSecEntry 4} acPMCPCallAttemptsPerSecMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMCPCallAttemptsPerSecEntry 5} acPMCPCallAttemptsPerSecVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMCPCallAttemptsPerSecEntry 6} acPMMegaco OBJECT IDENTIFIER ::= {acPMControlData 41} -- **************************************** -- acPMMegacoServiceChangeCount table declaration -- **************************************** acPMMegacoServiceChangeCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoServiceChangeCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of service changes, per method. Index: 0=FailOver, 1=Forced, 2=Graceful, 3=Restart, 4=Disconnected, 5=Handoff" ::= {acPMMegaco 1} -- **************************************** -- acPMMegacoServiceChangeCount table entry -- **************************************** acPMMegacoServiceChangeCountEntry OBJECT-TYPE SYNTAX AcPMMegacoServiceChangeCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoServiceChangeCountMethod,acPMMegacoServiceChangeCountInterval} ::= {acPMMegacoServiceChangeCountTable 1} -- **************************************** -- acPMMegacoServiceChangeCount TABLE -- **************************************** AcPMMegacoServiceChangeCountEntry ::= SEQUENCE { acPMMegacoServiceChangeCountMethod INTEGER, acPMMegacoServiceChangeCountInterval Unsigned32, acPMMegacoServiceChangeCountVal Gauge32 } acPMMegacoServiceChangeCountMethod OBJECT-TYPE SYNTAX INTEGER { failOver(0) , forced(1) , graceful(2) , restart(3) , disconnected(4) , handoff(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Method: 0=FailOver, 1=Forced, 2=Graceful, 3=Restart, 4=Disconnected, 5=Handoff." ::= {acPMMegacoServiceChangeCountEntry 1} acPMMegacoServiceChangeCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoServiceChangeCountEntry 2} acPMMegacoServiceChangeCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoServiceChangeCountEntry 3} -- **************************************** -- acPMCPCmdSuccessCount table declaration -- **************************************** acPMCPCmdSuccessCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCmdSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of successful commands, per command type. Index: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify" ::= {acPMMegaco 2} -- **************************************** -- acPMCPCmdSuccessCount table entry -- **************************************** acPMCPCmdSuccessCountEntry OBJECT-TYPE SYNTAX AcPMCPCmdSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPCmdSuccessCountCommandType,acPMCPCmdSuccessCountInterval} ::= {acPMCPCmdSuccessCountTable 1} -- **************************************** -- acPMCPCmdSuccessCount TABLE -- **************************************** AcPMCPCmdSuccessCountEntry ::= SEQUENCE { acPMCPCmdSuccessCountCommandType INTEGER, acPMCPCmdSuccessCountInterval Unsigned32, acPMCPCmdSuccessCountVal Gauge32, acPMCPCmdSuccessCountTotal Integer32 } acPMCPCmdSuccessCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Command type: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify." ::= {acPMCPCmdSuccessCountEntry 1} acPMCPCmdSuccessCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCmdSuccessCountEntry 2} acPMCPCmdSuccessCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPCmdSuccessCountEntry 3} acPMCPCmdSuccessCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPCmdSuccessCountEntry 4} -- **************************************** -- acPMCPCmdFailureCount table declaration -- **************************************** acPMCPCmdFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMCPCmdFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failing commands, per command type. Index: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify" ::= {acPMMegaco 3} -- **************************************** -- acPMCPCmdFailureCount table entry -- **************************************** acPMCPCmdFailureCountEntry OBJECT-TYPE SYNTAX AcPMCPCmdFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMCPCmdFailureCountCommandType,acPMCPCmdFailureCountInterval} ::= {acPMCPCmdFailureCountTable 1} -- **************************************** -- acPMCPCmdFailureCount TABLE -- **************************************** AcPMCPCmdFailureCountEntry ::= SEQUENCE { acPMCPCmdFailureCountCommandType INTEGER, acPMCPCmdFailureCountInterval Unsigned32, acPMCPCmdFailureCountVal Gauge32, acPMCPCmdFailureCountTotal Integer32 } acPMCPCmdFailureCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Command type: 0=add, 1=move, 2=modify, 3=subtract, 4=SC, 5=AuditValue, 6=AuditCapabilities, 7=Notify." ::= {acPMCPCmdFailureCountEntry 1} acPMCPCmdFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMCPCmdFailureCountEntry 2} acPMCPCmdFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMCPCmdFailureCountEntry 3} acPMCPCmdFailureCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMCPCmdFailureCountEntry 4} -- **************************************** -- acPMcpUMTSHandOverCount table declaration -- **************************************** acPMcpUMTSHandOverCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMcpUMTSHandOverCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of active channels per trunk (index: trunk number)." ::= {acPMMegaco 4} -- **************************************** -- acPMcpUMTSHandOverCount table entry -- **************************************** acPMcpUMTSHandOverCountEntry OBJECT-TYPE SYNTAX AcPMcpUMTSHandOverCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMcpUMTSHandOverCountInterval} ::= {acPMcpUMTSHandOverCountTable 1} -- **************************************** -- acPMcpUMTSHandOverCount TABLE -- **************************************** AcPMcpUMTSHandOverCountEntry ::= SEQUENCE { acPMcpUMTSHandOverCountInterval Unsigned32, acPMcpUMTSHandOverCountVal Gauge32 } acPMcpUMTSHandOverCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMcpUMTSHandOverCountEntry 1} acPMcpUMTSHandOverCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMcpUMTSHandOverCountEntry 2} -- **************************************** -- acPMMegacoAddFailureCount table declaration -- **************************************** acPMMegacoAddFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoAddFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of Megaco failures for Add" ::= {acPMMegaco 5} -- **************************************** -- acPMMegacoAddFailureCount table entry -- **************************************** acPMMegacoAddFailureCountEntry OBJECT-TYPE SYNTAX AcPMMegacoAddFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoAddFailureCountInterval} ::= {acPMMegacoAddFailureCountTable 1} -- **************************************** -- acPMMegacoAddFailureCount TABLE -- **************************************** AcPMMegacoAddFailureCountEntry ::= SEQUENCE { acPMMegacoAddFailureCountInterval Unsigned32, acPMMegacoAddFailureCountVal Gauge32 } acPMMegacoAddFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoAddFailureCountEntry 1} acPMMegacoAddFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoAddFailureCountEntry 2} -- **************************************** -- acPMMegacoModifyFailureCount table declaration -- **************************************** acPMMegacoModifyFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoModifyFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of Megaco failures for Modify " ::= {acPMMegaco 6} -- **************************************** -- acPMMegacoModifyFailureCount table entry -- **************************************** acPMMegacoModifyFailureCountEntry OBJECT-TYPE SYNTAX AcPMMegacoModifyFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoModifyFailureCountInterval} ::= {acPMMegacoModifyFailureCountTable 1} -- **************************************** -- acPMMegacoModifyFailureCount TABLE -- **************************************** AcPMMegacoModifyFailureCountEntry ::= SEQUENCE { acPMMegacoModifyFailureCountInterval Unsigned32, acPMMegacoModifyFailureCountVal Gauge32 } acPMMegacoModifyFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoModifyFailureCountEntry 1} acPMMegacoModifyFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoModifyFailureCountEntry 2} -- **************************************** -- acPMMegacoSuccessfulAddWithLoopback table declaration -- **************************************** acPMMegacoSuccessfulAddWithLoopbackTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoSuccessfulAddWithLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of successful Megaco Add commands with loopback." ::= {acPMMegaco 7} -- **************************************** -- acPMMegacoSuccessfulAddWithLoopback table entry -- **************************************** acPMMegacoSuccessfulAddWithLoopbackEntry OBJECT-TYPE SYNTAX AcPMMegacoSuccessfulAddWithLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoSuccessfulAddWithLoopbackInterval} ::= {acPMMegacoSuccessfulAddWithLoopbackTable 1} -- **************************************** -- acPMMegacoSuccessfulAddWithLoopback TABLE -- **************************************** AcPMMegacoSuccessfulAddWithLoopbackEntry ::= SEQUENCE { acPMMegacoSuccessfulAddWithLoopbackInterval Unsigned32, acPMMegacoSuccessfulAddWithLoopbackVal Gauge32 } acPMMegacoSuccessfulAddWithLoopbackInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoSuccessfulAddWithLoopbackEntry 1} acPMMegacoSuccessfulAddWithLoopbackVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoSuccessfulAddWithLoopbackEntry 2} -- **************************************** -- acPMMegacoFailedAddWithLoopback table declaration -- **************************************** acPMMegacoFailedAddWithLoopbackTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoFailedAddWithLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failed Megaco Add commands with loopback." ::= {acPMMegaco 8} -- **************************************** -- acPMMegacoFailedAddWithLoopback table entry -- **************************************** acPMMegacoFailedAddWithLoopbackEntry OBJECT-TYPE SYNTAX AcPMMegacoFailedAddWithLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoFailedAddWithLoopbackInterval} ::= {acPMMegacoFailedAddWithLoopbackTable 1} -- **************************************** -- acPMMegacoFailedAddWithLoopback TABLE -- **************************************** AcPMMegacoFailedAddWithLoopbackEntry ::= SEQUENCE { acPMMegacoFailedAddWithLoopbackInterval Unsigned32, acPMMegacoFailedAddWithLoopbackVal Gauge32 } acPMMegacoFailedAddWithLoopbackInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoFailedAddWithLoopbackEntry 1} acPMMegacoFailedAddWithLoopbackVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoFailedAddWithLoopbackEntry 2} -- **************************************** -- acPMMegacoOutgoingCommandSuccessCount table declaration -- **************************************** acPMMegacoOutgoingCommandSuccessCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoOutgoingCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of successful Megaco outgoing commands." ::= {acPMMegaco 9} -- **************************************** -- acPMMegacoOutgoingCommandSuccessCount table entry -- **************************************** acPMMegacoOutgoingCommandSuccessCountEntry OBJECT-TYPE SYNTAX AcPMMegacoOutgoingCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoOutgoingCommandSuccessCountInterval} ::= {acPMMegacoOutgoingCommandSuccessCountTable 1} -- **************************************** -- acPMMegacoOutgoingCommandSuccessCount TABLE -- **************************************** AcPMMegacoOutgoingCommandSuccessCountEntry ::= SEQUENCE { acPMMegacoOutgoingCommandSuccessCountInterval Unsigned32, acPMMegacoOutgoingCommandSuccessCountVal Gauge32 } acPMMegacoOutgoingCommandSuccessCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoOutgoingCommandSuccessCountEntry 1} acPMMegacoOutgoingCommandSuccessCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoOutgoingCommandSuccessCountEntry 2} -- **************************************** -- acPMMegacoOutgoingCommandFailureCount table declaration -- **************************************** acPMMegacoOutgoingCommandFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMegacoOutgoingCommandFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failed Megaco outgoing commands ." ::= {acPMMegaco 10} -- **************************************** -- acPMMegacoOutgoingCommandFailureCount table entry -- **************************************** acPMMegacoOutgoingCommandFailureCountEntry OBJECT-TYPE SYNTAX AcPMMegacoOutgoingCommandFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMegacoOutgoingCommandFailureCountInterval} ::= {acPMMegacoOutgoingCommandFailureCountTable 1} -- **************************************** -- acPMMegacoOutgoingCommandFailureCount TABLE -- **************************************** AcPMMegacoOutgoingCommandFailureCountEntry ::= SEQUENCE { acPMMegacoOutgoingCommandFailureCountInterval Unsigned32, acPMMegacoOutgoingCommandFailureCountVal Gauge32 } acPMMegacoOutgoingCommandFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMegacoOutgoingCommandFailureCountEntry 1} acPMMegacoOutgoingCommandFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMegacoOutgoingCommandFailureCountEntry 2} acPMMGCP OBJECT IDENTIFIER ::= {acPMControlData 51} -- **************************************** -- acPMMGCPRsipReasonCount table declaration -- **************************************** acPMMGCPRsipReasonCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPRsipReasonCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of RSIPs, per reason code." ::= {acPMMGCP 1} -- **************************************** -- acPMMGCPRsipReasonCount table entry -- **************************************** acPMMGCPRsipReasonCountEntry OBJECT-TYPE SYNTAX AcPMMGCPRsipReasonCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPRsipReasonCountReasonCode,acPMMGCPRsipReasonCountInterval} ::= {acPMMGCPRsipReasonCountTable 1} -- **************************************** -- acPMMGCPRsipReasonCount TABLE -- **************************************** AcPMMGCPRsipReasonCountEntry ::= SEQUENCE { acPMMGCPRsipReasonCountReasonCode INTEGER, acPMMGCPRsipReasonCountInterval Unsigned32, acPMMGCPRsipReasonCountVal Counter32 } acPMMGCPRsipReasonCountReasonCode OBJECT-TYPE SYNTAX INTEGER { restart(0) , forced(1) , disconnected(2) , keepAlive(3) , graceful(4) , cancelGraceful(5) , resetBoard(6) , nonVoice(7) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Reason code. Index: 0=Restart, 1=Forced, 2=Disconnected, 3=KeepAlive, 4=Graceful, 5=CancelGraceful, 6=ResetBoard, 7=NonVoice." ::= {acPMMGCPRsipReasonCountEntry 1} acPMMGCPRsipReasonCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPRsipReasonCountEntry 2} acPMMGCPRsipReasonCountVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPRsipReasonCountEntry 3} -- **************************************** -- acPMMGCPGeneratedDLCX table declaration -- **************************************** acPMMGCPGeneratedDLCXTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPGeneratedDLCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This parameter counts the number of gateway-generated DLCX commands (as opposed to DLCX commands received from the call-agent)." ::= {acPMMGCP 2} -- **************************************** -- acPMMGCPGeneratedDLCX table entry -- **************************************** acPMMGCPGeneratedDLCXEntry OBJECT-TYPE SYNTAX AcPMMGCPGeneratedDLCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPGeneratedDLCXInterval} ::= {acPMMGCPGeneratedDLCXTable 1} -- **************************************** -- acPMMGCPGeneratedDLCX TABLE -- **************************************** AcPMMGCPGeneratedDLCXEntry ::= SEQUENCE { acPMMGCPGeneratedDLCXInterval Unsigned32, acPMMGCPGeneratedDLCXVal Counter32 } acPMMGCPGeneratedDLCXInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPGeneratedDLCXEntry 1} acPMMGCPGeneratedDLCXVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPGeneratedDLCXEntry 2} -- **************************************** -- acPMMGCPCommandSuccessCount table declaration -- **************************************** acPMMGCPCommandSuccessCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of successful commands, per command type. Index: EPCF (0),CRCX (1),MDCX (2),DLCX (3),RQNT (4),NTFY (5),AUEP(6),AUCX (7),RSIP(8)." ::= {acPMMGCP 3} -- **************************************** -- acPMMGCPCommandSuccessCount table entry -- **************************************** acPMMGCPCommandSuccessCountEntry OBJECT-TYPE SYNTAX AcPMMGCPCommandSuccessCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPCommandSuccessCountCommandType,acPMMGCPCommandSuccessCountInterval} ::= {acPMMGCPCommandSuccessCountTable 1} -- **************************************** -- acPMMGCPCommandSuccessCount TABLE -- **************************************** AcPMMGCPCommandSuccessCountEntry ::= SEQUENCE { acPMMGCPCommandSuccessCountCommandType INTEGER, acPMMGCPCommandSuccessCountInterval Unsigned32, acPMMGCPCommandSuccessCountVal Gauge32, acPMMGCPCommandSuccessCountTotal Integer32 } acPMMGCPCommandSuccessCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Command type:EPCF (0),CRCX (1),MDCX (2),DLCX (3),RQNT (4),NTFY (5),AUEP(6),AUCX (7),RSIP(8)." ::= {acPMMGCPCommandSuccessCountEntry 1} acPMMGCPCommandSuccessCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPCommandSuccessCountEntry 2} acPMMGCPCommandSuccessCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPCommandSuccessCountEntry 3} acPMMGCPCommandSuccessCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMMGCPCommandSuccessCountEntry 4} -- **************************************** -- acPMMGCPCommandFailureCount table declaration -- **************************************** acPMMGCPCommandFailureCountTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPCommandFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failing commands, per command type. Index: EPCF (0),CRCX (1),MDCX (2),DLCX (3),RQNT (4),NTFY (5),AUEP(6),AUCX (7),RSIP(8)." ::= {acPMMGCP 4} -- **************************************** -- acPMMGCPCommandFailureCount table entry -- **************************************** acPMMGCPCommandFailureCountEntry OBJECT-TYPE SYNTAX AcPMMGCPCommandFailureCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPCommandFailureCountCommandType,acPMMGCPCommandFailureCountInterval} ::= {acPMMGCPCommandFailureCountTable 1} -- **************************************** -- acPMMGCPCommandFailureCount TABLE -- **************************************** AcPMMGCPCommandFailureCountEntry ::= SEQUENCE { acPMMGCPCommandFailureCountCommandType INTEGER, acPMMGCPCommandFailureCountInterval Unsigned32, acPMMGCPCommandFailureCountVal Gauge32, acPMMGCPCommandFailureCountTotal Integer32 } acPMMGCPCommandFailureCountCommandType OBJECT-TYPE SYNTAX INTEGER { add(0) , move(1) , modify(2) , subtract(3) , sc(4) , auditValue(5) , auditCapabilities(6) , notify(7) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Command type:EPCF (0),CRCX (1),MDCX (2),DLCX (3),RQNT (4),NTFY (5),AUEP(6),AUCX (7),RSIP(8)." ::= {acPMMGCPCommandFailureCountEntry 1} acPMMGCPCommandFailureCountInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPCommandFailureCountEntry 2} acPMMGCPCommandFailureCountVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPCommandFailureCountEntry 3} acPMMGCPCommandFailureCountTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMMGCPCommandFailureCountEntry 4} -- **************************************** -- acPMMGCPLoopbackCRCX table declaration -- **************************************** acPMMGCPLoopbackCRCXTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPLoopbackCRCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acPMMGCP 5} -- **************************************** -- acPMMGCPLoopbackCRCX table entry -- **************************************** acPMMGCPLoopbackCRCXEntry OBJECT-TYPE SYNTAX AcPMMGCPLoopbackCRCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPLoopbackCRCXInterval} ::= {acPMMGCPLoopbackCRCXTable 1} -- **************************************** -- acPMMGCPLoopbackCRCX TABLE -- **************************************** AcPMMGCPLoopbackCRCXEntry ::= SEQUENCE { acPMMGCPLoopbackCRCXInterval Unsigned32, acPMMGCPLoopbackCRCXVal Counter32 } acPMMGCPLoopbackCRCXInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPLoopbackCRCXEntry 1} acPMMGCPLoopbackCRCXVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPLoopbackCRCXEntry 2} -- **************************************** -- acPMMGCPFailedLoopbackCRCX table declaration -- **************************************** acPMMGCPFailedLoopbackCRCXTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPFailedLoopbackCRCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acPMMGCP 6} -- **************************************** -- acPMMGCPFailedLoopbackCRCX table entry -- **************************************** acPMMGCPFailedLoopbackCRCXEntry OBJECT-TYPE SYNTAX AcPMMGCPFailedLoopbackCRCXEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPFailedLoopbackCRCXInterval} ::= {acPMMGCPFailedLoopbackCRCXTable 1} -- **************************************** -- acPMMGCPFailedLoopbackCRCX TABLE -- **************************************** AcPMMGCPFailedLoopbackCRCXEntry ::= SEQUENCE { acPMMGCPFailedLoopbackCRCXInterval Unsigned32, acPMMGCPFailedLoopbackCRCXVal Counter32 } acPMMGCPFailedLoopbackCRCXInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPFailedLoopbackCRCXEntry 1} acPMMGCPFailedLoopbackCRCXVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPFailedLoopbackCRCXEntry 2} -- **************************************** -- acPMMGCPGeneratedNTFY table declaration -- **************************************** acPMMGCPGeneratedNTFYTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPGeneratedNTFYEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acPMMGCP 7} -- **************************************** -- acPMMGCPGeneratedNTFY table entry -- **************************************** acPMMGCPGeneratedNTFYEntry OBJECT-TYPE SYNTAX AcPMMGCPGeneratedNTFYEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPGeneratedNTFYInterval} ::= {acPMMGCPGeneratedNTFYTable 1} -- **************************************** -- acPMMGCPGeneratedNTFY TABLE -- **************************************** AcPMMGCPGeneratedNTFYEntry ::= SEQUENCE { acPMMGCPGeneratedNTFYInterval Unsigned32, acPMMGCPGeneratedNTFYVal Counter32 } acPMMGCPGeneratedNTFYInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPGeneratedNTFYEntry 1} acPMMGCPGeneratedNTFYVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPGeneratedNTFYEntry 2} -- **************************************** -- acPMMGCPFailedNTFYResponses table declaration -- **************************************** acPMMGCPFailedNTFYResponsesTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPFailedNTFYResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acPMMGCP 8} -- **************************************** -- acPMMGCPFailedNTFYResponses table entry -- **************************************** acPMMGCPFailedNTFYResponsesEntry OBJECT-TYPE SYNTAX AcPMMGCPFailedNTFYResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPFailedNTFYResponsesInterval} ::= {acPMMGCPFailedNTFYResponsesTable 1} -- **************************************** -- acPMMGCPFailedNTFYResponses TABLE -- **************************************** AcPMMGCPFailedNTFYResponsesEntry ::= SEQUENCE { acPMMGCPFailedNTFYResponsesInterval Unsigned32, acPMMGCPFailedNTFYResponsesVal Counter32 } acPMMGCPFailedNTFYResponsesInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPFailedNTFYResponsesEntry 1} acPMMGCPFailedNTFYResponsesVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPFailedNTFYResponsesEntry 2} -- **************************************** -- acPMMGCPFailedRSIPResponses table declaration -- **************************************** acPMMGCPFailedRSIPResponsesTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPFailedRSIPResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" ::= {acPMMGCP 9} -- **************************************** -- acPMMGCPFailedRSIPResponses table entry -- **************************************** acPMMGCPFailedRSIPResponsesEntry OBJECT-TYPE SYNTAX AcPMMGCPFailedRSIPResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPFailedRSIPResponsesInterval} ::= {acPMMGCPFailedRSIPResponsesTable 1} -- **************************************** -- acPMMGCPFailedRSIPResponses TABLE -- **************************************** AcPMMGCPFailedRSIPResponsesEntry ::= SEQUENCE { acPMMGCPFailedRSIPResponsesInterval Unsigned32, acPMMGCPFailedRSIPResponsesVal Counter32 } acPMMGCPFailedRSIPResponsesInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPFailedRSIPResponsesEntry 1} acPMMGCPFailedRSIPResponsesVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPFailedRSIPResponsesEntry 2} -- **************************************** -- acPMMGCPFailedCRCXResponses table declaration -- **************************************** acPMMGCPFailedCRCXResponsesTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPFailedCRCXResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failed responses to CRCX commands, per reason code." ::= {acPMMGCP 10} -- **************************************** -- acPMMGCPFailedCRCXResponses table entry -- **************************************** acPMMGCPFailedCRCXResponsesEntry OBJECT-TYPE SYNTAX AcPMMGCPFailedCRCXResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPFailedCRCXResponsesReasonCode,acPMMGCPFailedCRCXResponsesInterval} ::= {acPMMGCPFailedCRCXResponsesTable 1} -- **************************************** -- acPMMGCPFailedCRCXResponses TABLE -- **************************************** AcPMMGCPFailedCRCXResponsesEntry ::= SEQUENCE { acPMMGCPFailedCRCXResponsesReasonCode INTEGER, acPMMGCPFailedCRCXResponsesInterval Unsigned32, acPMMGCPFailedCRCXResponsesVal Counter32 } acPMMGCPFailedCRCXResponsesReasonCode OBJECT-TYPE SYNTAX INTEGER { reasoncode-400(0) , reasoncode-401(1) , reasoncode-402(2) , reasoncode-403(3) , reasoncode-404(4) , reasoncode-405(5) , reasoncode-406(6) , reasoncode-407(7) , reasoncode-409(8) , reasoncode-410(9) , reasoncode-500(10) , reasoncode-501(11) , reasoncode-502(12) , reasoncode-503(13) , reasoncode-504(14) , reasoncode-505(15) , reasoncode-506(16) , reasoncode-507(17) , reasoncode-508(18) , reasoncode-509(19) , reasoncode-510(20) , reasoncode-511(21) , reasoncode-512(22) , reasoncode-513(23) , reasoncode-514(24) , reasoncode-515(25) , reasoncode-516(26) , reasoncode-517(27) , reasoncode-518(28) , reasoncode-519(29) , reasoncode-520(30) , reasoncode-521(31) , reasoncode-522(32) , reasoncode-523(33) , reasoncode-524(34) , reasoncode-525(35) , reasoncode-526(36) , reasoncode-527(37) , reasoncode-528(38) , reasoncode-529(39) , reasoncode-530(40) , reasoncode-531(41) , reasoncode-532(42) , reasoncode-533(43) , reasoncode-534(44) , reasoncode-535(45) , reasoncode-536(46) , reasoncode-537(47) , reasoncode-538(48) , reasoncode-539(49) , reasoncode-540(50) , reasoncode-541(51) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Reason code Index. The Numbers at the values are as in the RFC." ::= {acPMMGCPFailedCRCXResponsesEntry 1} acPMMGCPFailedCRCXResponsesInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPFailedCRCXResponsesEntry 2} acPMMGCPFailedCRCXResponsesVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPFailedCRCXResponsesEntry 3} -- **************************************** -- acPMMGCPFailedMDCXResponses table declaration -- **************************************** acPMMGCPFailedMDCXResponsesTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPFailedMDCXResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of failed responses to CRCX commands, per reason code." ::= {acPMMGCP 11} -- **************************************** -- acPMMGCPFailedMDCXResponses table entry -- **************************************** acPMMGCPFailedMDCXResponsesEntry OBJECT-TYPE SYNTAX AcPMMGCPFailedMDCXResponsesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPFailedMDCXResponsesReasonCode,acPMMGCPFailedMDCXResponsesInterval} ::= {acPMMGCPFailedMDCXResponsesTable 1} -- **************************************** -- acPMMGCPFailedMDCXResponses TABLE -- **************************************** AcPMMGCPFailedMDCXResponsesEntry ::= SEQUENCE { acPMMGCPFailedMDCXResponsesReasonCode INTEGER, acPMMGCPFailedMDCXResponsesInterval Unsigned32, acPMMGCPFailedMDCXResponsesVal Counter32 } acPMMGCPFailedMDCXResponsesReasonCode OBJECT-TYPE SYNTAX INTEGER { reasoncode-400(0) , reasoncode-401(1) , reasoncode-402(2) , reasoncode-403(3) , reasoncode-404(4) , reasoncode-405(5) , reasoncode-406(6) , reasoncode-407(7) , reasoncode-409(8) , reasoncode-410(9) , reasoncode-500(10) , reasoncode-501(11) , reasoncode-502(12) , reasoncode-503(13) , reasoncode-504(14) , reasoncode-505(15) , reasoncode-506(16) , reasoncode-507(17) , reasoncode-508(18) , reasoncode-509(19) , reasoncode-510(20) , reasoncode-511(21) , reasoncode-512(22) , reasoncode-513(23) , reasoncode-514(24) , reasoncode-515(25) , reasoncode-516(26) , reasoncode-517(27) , reasoncode-518(28) , reasoncode-519(29) , reasoncode-520(30) , reasoncode-521(31) , reasoncode-522(32) , reasoncode-523(33) , reasoncode-524(34) , reasoncode-525(35) , reasoncode-526(36) , reasoncode-527(37) , reasoncode-528(38) , reasoncode-529(39) , reasoncode-530(40) , reasoncode-531(41) , reasoncode-532(42) , reasoncode-533(43) , reasoncode-534(44) , reasoncode-535(45) , reasoncode-536(46) , reasoncode-537(47) , reasoncode-538(48) , reasoncode-539(49) , reasoncode-540(50) , reasoncode-541(51) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Reason code Index. The Numbers at the values are as in the RFC." ::= {acPMMGCPFailedMDCXResponsesEntry 1} acPMMGCPFailedMDCXResponsesInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPFailedMDCXResponsesEntry 2} acPMMGCPFailedMDCXResponsesVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPFailedMDCXResponsesEntry 3} -- **************************************** -- acPMMGCPGeneratedDLCXPerReasonCode table declaration -- **************************************** acPMMGCPGeneratedDLCXPerReasonCodeTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMMGCPGeneratedDLCXPerReasonCodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of gateway-generated DLCX commands per reason code. when you choose 0 its 900(ENDPOINT_MALFUNCTIONING) and so on." ::= {acPMMGCP 12} -- **************************************** -- acPMMGCPGeneratedDLCXPerReasonCode table entry -- **************************************** acPMMGCPGeneratedDLCXPerReasonCodeEntry OBJECT-TYPE SYNTAX AcPMMGCPGeneratedDLCXPerReasonCodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMMGCPGeneratedDLCXPerReasonCodeReasonCode,acPMMGCPGeneratedDLCXPerReasonCodeInterval} ::= {acPMMGCPGeneratedDLCXPerReasonCodeTable 1} -- **************************************** -- acPMMGCPGeneratedDLCXPerReasonCode TABLE -- **************************************** AcPMMGCPGeneratedDLCXPerReasonCodeEntry ::= SEQUENCE { acPMMGCPGeneratedDLCXPerReasonCodeReasonCode INTEGER, acPMMGCPGeneratedDLCXPerReasonCodeInterval Unsigned32, acPMMGCPGeneratedDLCXPerReasonCodeVal Counter32 } acPMMGCPGeneratedDLCXPerReasonCodeReasonCode OBJECT-TYPE SYNTAX INTEGER { eNDPOINT-MALFUNCTIONING-900(0) , eNDPOINT-TAKEN-OUT-OF-SERVICE-901(1) , lOSS-OF-LOWER-LAYER-CONNECTIVITY-902(2) , qOS-RESOURCE-RESERVATION-WAS-LOST-903(3) , mANUAL-INTERVENTION-904(4) , fACILITY-FAILURE-905(5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Reason code Index. The Numbers at the values are as in the RFC." ::= {acPMMGCPGeneratedDLCXPerReasonCodeEntry 1} acPMMGCPGeneratedDLCXPerReasonCodeInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMMGCPGeneratedDLCXPerReasonCodeEntry 2} acPMMGCPGeneratedDLCXPerReasonCodeVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMMGCPGeneratedDLCXPerReasonCodeEntry 3} acPMSIP OBJECT IDENTIFIER ::= {acPMControlData 52} -- **************************************** -- acPMSIPAttemptedCalls table declaration -- **************************************** acPMSIPAttemptedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPAttemptedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of attempted calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 1} -- **************************************** -- acPMSIPAttemptedCalls table entry -- **************************************** acPMSIPAttemptedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPAttemptedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPAttemptedCallsDirection,acPMSIPAttemptedCallsInterval} ::= {acPMSIPAttemptedCallsTable 1} -- **************************************** -- acPMSIPAttemptedCalls TABLE -- **************************************** AcPMSIPAttemptedCallsEntry ::= SEQUENCE { acPMSIPAttemptedCallsDirection INTEGER, acPMSIPAttemptedCallsInterval Unsigned32, acPMSIPAttemptedCallsVal Counter32 } acPMSIPAttemptedCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPAttemptedCallsEntry 1} acPMSIPAttemptedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPAttemptedCallsEntry 2} acPMSIPAttemptedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPAttemptedCallsEntry 3} -- **************************************** -- acPMSIPCallDuration table declaration -- **************************************** acPMSIPCallDurationTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPCallDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Call Duration (Index 0 for Tel2IP and Index 1 for IP2Tel);The Total preprty gives the sum of all calls duration, while the Value property is for the last call only" ::= {acPMSIP 2} -- **************************************** -- acPMSIPCallDuration table entry -- **************************************** acPMSIPCallDurationEntry OBJECT-TYPE SYNTAX AcPMSIPCallDurationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPCallDurationDirection,acPMSIPCallDurationInterval} ::= {acPMSIPCallDurationTable 1} -- **************************************** -- acPMSIPCallDuration TABLE -- **************************************** AcPMSIPCallDurationEntry ::= SEQUENCE { acPMSIPCallDurationDirection INTEGER, acPMSIPCallDurationInterval Unsigned32, acPMSIPCallDurationVal Gauge32, acPMSIPCallDurationAverage Integer32, acPMSIPCallDurationMax Integer32, acPMSIPCallDurationMin Integer32, acPMSIPCallDurationVolume Counter32, acPMSIPCallDurationTimeBelowLowThreshold Integer32, acPMSIPCallDurationTimeBetweenThresholds Integer32, acPMSIPCallDurationTimeAboveHighThreshold Integer32, acPMSIPCallDurationFullDayAverage Integer32, acPMSIPCallDurationTotal Integer32 } acPMSIPCallDurationDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPCallDurationEntry 1} acPMSIPCallDurationInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPCallDurationEntry 2} acPMSIPCallDurationVal OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPCallDurationEntry 3} acPMSIPCallDurationAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Average value with in the period time." ::= {acPMSIPCallDurationEntry 4} acPMSIPCallDurationMax OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value with in the period time." ::= {acPMSIPCallDurationEntry 5} acPMSIPCallDurationMin OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value with in the period time." ::= {acPMSIPCallDurationEntry 6} acPMSIPCallDurationVolume OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Activity volume." ::= {acPMSIPCallDurationEntry 7} acPMSIPCallDurationTimeBelowLowThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is below what was determined as the low threshold." ::= {acPMSIPCallDurationEntry 8} acPMSIPCallDurationTimeBetweenThresholds OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is above what was determined as the high threshold." ::= {acPMSIPCallDurationEntry 9} acPMSIPCallDurationTimeAboveHighThreshold OBJECT-TYPE SYNTAX Integer32 (-1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Percent of interval time for which gauge is between what were determined as the low and high thresholds." ::= {acPMSIPCallDurationEntry 10} acPMSIPCallDurationFullDayAverage OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The average of full 24 hours." ::= {acPMSIPCallDurationEntry 11} acPMSIPCallDurationTotal OBJECT-TYPE SYNTAX Integer32 (-1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Total since last reset." ::= {acPMSIPCallDurationEntry 12} -- **************************************** -- acPMSIPNoMatchCalls table declaration -- **************************************** acPMSIPNoMatchCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPNoMatchCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of no match calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 3} -- **************************************** -- acPMSIPNoMatchCalls table entry -- **************************************** acPMSIPNoMatchCallsEntry OBJECT-TYPE SYNTAX AcPMSIPNoMatchCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPNoMatchCallsDirection,acPMSIPNoMatchCallsInterval} ::= {acPMSIPNoMatchCallsTable 1} -- **************************************** -- acPMSIPNoMatchCalls TABLE -- **************************************** AcPMSIPNoMatchCallsEntry ::= SEQUENCE { acPMSIPNoMatchCallsDirection INTEGER, acPMSIPNoMatchCallsInterval Unsigned32, acPMSIPNoMatchCallsVal Counter32 } acPMSIPNoMatchCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPNoMatchCallsEntry 1} acPMSIPNoMatchCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPNoMatchCallsEntry 2} acPMSIPNoMatchCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPNoMatchCallsEntry 3} -- **************************************** -- acPMSIPBusyCalls table declaration -- **************************************** acPMSIPBusyCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPBusyCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of busy calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 4} -- **************************************** -- acPMSIPBusyCalls table entry -- **************************************** acPMSIPBusyCallsEntry OBJECT-TYPE SYNTAX AcPMSIPBusyCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPBusyCallsDirection,acPMSIPBusyCallsInterval} ::= {acPMSIPBusyCallsTable 1} -- **************************************** -- acPMSIPBusyCalls TABLE -- **************************************** AcPMSIPBusyCallsEntry ::= SEQUENCE { acPMSIPBusyCallsDirection INTEGER, acPMSIPBusyCallsInterval Unsigned32, acPMSIPBusyCallsVal Counter32 } acPMSIPBusyCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPBusyCallsEntry 1} acPMSIPBusyCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPBusyCallsEntry 2} acPMSIPBusyCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPBusyCallsEntry 3} -- **************************************** -- acPMSIPNoAnswerCalls table declaration -- **************************************** acPMSIPNoAnswerCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPNoAnswerCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of no answer calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 5} -- **************************************** -- acPMSIPNoAnswerCalls table entry -- **************************************** acPMSIPNoAnswerCallsEntry OBJECT-TYPE SYNTAX AcPMSIPNoAnswerCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPNoAnswerCallsDirection,acPMSIPNoAnswerCallsInterval} ::= {acPMSIPNoAnswerCallsTable 1} -- **************************************** -- acPMSIPNoAnswerCalls TABLE -- **************************************** AcPMSIPNoAnswerCallsEntry ::= SEQUENCE { acPMSIPNoAnswerCallsDirection INTEGER, acPMSIPNoAnswerCallsInterval Unsigned32, acPMSIPNoAnswerCallsVal Counter32 } acPMSIPNoAnswerCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPNoAnswerCallsEntry 1} acPMSIPNoAnswerCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPNoAnswerCallsEntry 2} acPMSIPNoAnswerCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPNoAnswerCallsEntry 3} -- **************************************** -- acPMSIPNoRouteCalls table declaration -- **************************************** acPMSIPNoRouteCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPNoRouteCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of no route calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 6} -- **************************************** -- acPMSIPNoRouteCalls table entry -- **************************************** acPMSIPNoRouteCallsEntry OBJECT-TYPE SYNTAX AcPMSIPNoRouteCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPNoRouteCallsDirection,acPMSIPNoRouteCallsInterval} ::= {acPMSIPNoRouteCallsTable 1} -- **************************************** -- acPMSIPNoRouteCalls TABLE -- **************************************** AcPMSIPNoRouteCallsEntry ::= SEQUENCE { acPMSIPNoRouteCallsDirection INTEGER, acPMSIPNoRouteCallsInterval Unsigned32, acPMSIPNoRouteCallsVal Counter32 } acPMSIPNoRouteCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPNoRouteCallsEntry 1} acPMSIPNoRouteCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPNoRouteCallsEntry 2} acPMSIPNoRouteCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPNoRouteCallsEntry 3} -- **************************************** -- acPMSIPFailCalls table declaration -- **************************************** acPMSIPFailCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPFailCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of calls that failed because of other reasons (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 7} -- **************************************** -- acPMSIPFailCalls table entry -- **************************************** acPMSIPFailCallsEntry OBJECT-TYPE SYNTAX AcPMSIPFailCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPFailCallsDirection,acPMSIPFailCallsInterval} ::= {acPMSIPFailCallsTable 1} -- **************************************** -- acPMSIPFailCalls TABLE -- **************************************** AcPMSIPFailCallsEntry ::= SEQUENCE { acPMSIPFailCallsDirection INTEGER, acPMSIPFailCallsInterval Unsigned32, acPMSIPFailCallsVal Counter32 } acPMSIPFailCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPFailCallsEntry 1} acPMSIPFailCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPFailCallsEntry 2} acPMSIPFailCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPFailCallsEntry 3} -- **************************************** -- acPMSIPEstablishedCalls table declaration -- **************************************** acPMSIPEstablishedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of established calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 8} -- **************************************** -- acPMSIPEstablishedCalls table entry -- **************************************** acPMSIPEstablishedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPEstablishedCallsDirection,acPMSIPEstablishedCallsInterval} ::= {acPMSIPEstablishedCallsTable 1} -- **************************************** -- acPMSIPEstablishedCalls TABLE -- **************************************** AcPMSIPEstablishedCallsEntry ::= SEQUENCE { acPMSIPEstablishedCallsDirection INTEGER, acPMSIPEstablishedCallsInterval Unsigned32, acPMSIPEstablishedCallsVal Counter32 } acPMSIPEstablishedCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPEstablishedCallsEntry 1} acPMSIPEstablishedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPEstablishedCallsEntry 2} acPMSIPEstablishedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPEstablishedCallsEntry 3} -- **************************************** -- acPMSIPFaxAttemptedCalls table declaration -- **************************************** acPMSIPFaxAttemptedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPFaxAttemptedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of attempted fax calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 9} -- **************************************** -- acPMSIPFaxAttemptedCalls table entry -- **************************************** acPMSIPFaxAttemptedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPFaxAttemptedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPFaxAttemptedCallsDirection,acPMSIPFaxAttemptedCallsInterval} ::= {acPMSIPFaxAttemptedCallsTable 1} -- **************************************** -- acPMSIPFaxAttemptedCalls TABLE -- **************************************** AcPMSIPFaxAttemptedCallsEntry ::= SEQUENCE { acPMSIPFaxAttemptedCallsDirection INTEGER, acPMSIPFaxAttemptedCallsInterval Unsigned32, acPMSIPFaxAttemptedCallsVal Counter32 } acPMSIPFaxAttemptedCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPFaxAttemptedCallsEntry 1} acPMSIPFaxAttemptedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPFaxAttemptedCallsEntry 2} acPMSIPFaxAttemptedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPFaxAttemptedCallsEntry 3} -- **************************************** -- acPMSIPFaxSuccessCalls table declaration -- **************************************** acPMSIPFaxSuccessCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPFaxSuccessCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of success fax calls (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 10} -- **************************************** -- acPMSIPFaxSuccessCalls table entry -- **************************************** acPMSIPFaxSuccessCallsEntry OBJECT-TYPE SYNTAX AcPMSIPFaxSuccessCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPFaxSuccessCallsDirection,acPMSIPFaxSuccessCallsInterval} ::= {acPMSIPFaxSuccessCallsTable 1} -- **************************************** -- acPMSIPFaxSuccessCalls TABLE -- **************************************** AcPMSIPFaxSuccessCallsEntry ::= SEQUENCE { acPMSIPFaxSuccessCallsDirection INTEGER, acPMSIPFaxSuccessCallsInterval Unsigned32, acPMSIPFaxSuccessCallsVal Counter32 } acPMSIPFaxSuccessCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPFaxSuccessCallsEntry 1} acPMSIPFaxSuccessCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPFaxSuccessCallsEntry 2} acPMSIPFaxSuccessCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPFaxSuccessCallsEntry 3} -- **************************************** -- acPMSIPForwardedCalls table declaration -- **************************************** acPMSIPForwardedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPForwardedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of calls released due to forwarding (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 11} -- **************************************** -- acPMSIPForwardedCalls table entry -- **************************************** acPMSIPForwardedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPForwardedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPForwardedCallsDirection,acPMSIPForwardedCallsInterval} ::= {acPMSIPForwardedCallsTable 1} -- **************************************** -- acPMSIPForwardedCalls TABLE -- **************************************** AcPMSIPForwardedCallsEntry ::= SEQUENCE { acPMSIPForwardedCallsDirection INTEGER, acPMSIPForwardedCallsInterval Unsigned32, acPMSIPForwardedCallsVal Counter32 } acPMSIPForwardedCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPForwardedCallsEntry 1} acPMSIPForwardedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPForwardedCallsEntry 2} acPMSIPForwardedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPForwardedCallsEntry 3} -- **************************************** -- acPMSIPNoResourcesCalls table declaration -- **************************************** acPMSIPNoResourcesCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPNoResourcesCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of calls released because of no resources (Index 0 for TEL2IP and Index 1 for IP2TEL)" ::= {acPMSIP 12} -- **************************************** -- acPMSIPNoResourcesCalls table entry -- **************************************** acPMSIPNoResourcesCallsEntry OBJECT-TYPE SYNTAX AcPMSIPNoResourcesCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPNoResourcesCallsDirection,acPMSIPNoResourcesCallsInterval} ::= {acPMSIPNoResourcesCallsTable 1} -- **************************************** -- acPMSIPNoResourcesCalls TABLE -- **************************************** AcPMSIPNoResourcesCallsEntry ::= SEQUENCE { acPMSIPNoResourcesCallsDirection INTEGER, acPMSIPNoResourcesCallsInterval Unsigned32, acPMSIPNoResourcesCallsVal Counter32 } acPMSIPNoResourcesCallsDirection OBJECT-TYPE SYNTAX INTEGER { tel2IP(0) , iP2Tel(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Direction index - TEL2IP(0), IP2TEL(1)." ::= {acPMSIPNoResourcesCallsEntry 1} acPMSIPNoResourcesCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPNoResourcesCallsEntry 2} acPMSIPNoResourcesCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPNoResourcesCallsEntry 3} -- **************************************** -- acPMSIPTel2IPTrunkEstablishedCalls table declaration -- **************************************** acPMSIPTel2IPTrunkEstablishedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPTel2IPTrunkEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of Tel2IP established calls per trunk." ::= {acPMSIP 13} -- **************************************** -- acPMSIPTel2IPTrunkEstablishedCalls table entry -- **************************************** acPMSIPTel2IPTrunkEstablishedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPTel2IPTrunkEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPTel2IPTrunkEstablishedCallsTrunkNum,acPMSIPTel2IPTrunkEstablishedCallsInterval} ::= {acPMSIPTel2IPTrunkEstablishedCallsTable 1} -- **************************************** -- acPMSIPTel2IPTrunkEstablishedCalls TABLE -- **************************************** AcPMSIPTel2IPTrunkEstablishedCallsEntry ::= SEQUENCE { acPMSIPTel2IPTrunkEstablishedCallsTrunkNum Unsigned32, acPMSIPTel2IPTrunkEstablishedCallsInterval Unsigned32, acPMSIPTel2IPTrunkEstablishedCallsVal Counter32 } acPMSIPTel2IPTrunkEstablishedCallsTrunkNum OBJECT-TYPE SYNTAX Unsigned32 (0..83) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk number. 0 is the first trunk." ::= {acPMSIPTel2IPTrunkEstablishedCallsEntry 1} acPMSIPTel2IPTrunkEstablishedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPTel2IPTrunkEstablishedCallsEntry 2} acPMSIPTel2IPTrunkEstablishedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPTel2IPTrunkEstablishedCallsEntry 3} -- **************************************** -- acPMSIPIP2TelTrunkEstablishedCalls table declaration -- **************************************** acPMSIPIP2TelTrunkEstablishedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPIP2TelTrunkEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of IP2Tel established calls per trunk." ::= {acPMSIP 14} -- **************************************** -- acPMSIPIP2TelTrunkEstablishedCalls table entry -- **************************************** acPMSIPIP2TelTrunkEstablishedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPIP2TelTrunkEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPIP2TelTrunkEstablishedCallsTrunkNum,acPMSIPIP2TelTrunkEstablishedCallsInterval} ::= {acPMSIPIP2TelTrunkEstablishedCallsTable 1} -- **************************************** -- acPMSIPIP2TelTrunkEstablishedCalls TABLE -- **************************************** AcPMSIPIP2TelTrunkEstablishedCallsEntry ::= SEQUENCE { acPMSIPIP2TelTrunkEstablishedCallsTrunkNum Unsigned32, acPMSIPIP2TelTrunkEstablishedCallsInterval Unsigned32, acPMSIPIP2TelTrunkEstablishedCallsVal Counter32 } acPMSIPIP2TelTrunkEstablishedCallsTrunkNum OBJECT-TYPE SYNTAX Unsigned32 (0..83) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk number. 0 is the first trunk." ::= {acPMSIPIP2TelTrunkEstablishedCallsEntry 1} acPMSIPIP2TelTrunkEstablishedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPIP2TelTrunkEstablishedCallsEntry 2} acPMSIPIP2TelTrunkEstablishedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPIP2TelTrunkEstablishedCallsEntry 3} -- **************************************** -- acPMSIPTel2IPTrunkGroupEstablishedCalls table declaration -- **************************************** acPMSIPTel2IPTrunkGroupEstablishedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPTel2IPTrunkGroupEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of Tel2IP established calls per trunk group." ::= {acPMSIP 15} -- **************************************** -- acPMSIPTel2IPTrunkGroupEstablishedCalls table entry -- **************************************** acPMSIPTel2IPTrunkGroupEstablishedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPTel2IPTrunkGroupEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPTel2IPTrunkGroupEstablishedCallsGroupNum,acPMSIPTel2IPTrunkGroupEstablishedCallsInterval} ::= {acPMSIPTel2IPTrunkGroupEstablishedCallsTable 1} -- **************************************** -- acPMSIPTel2IPTrunkGroupEstablishedCalls TABLE -- **************************************** AcPMSIPTel2IPTrunkGroupEstablishedCallsEntry ::= SEQUENCE { acPMSIPTel2IPTrunkGroupEstablishedCallsGroupNum Unsigned32, acPMSIPTel2IPTrunkGroupEstablishedCallsInterval Unsigned32, acPMSIPTel2IPTrunkGroupEstablishedCallsVal Counter32 } acPMSIPTel2IPTrunkGroupEstablishedCallsGroupNum OBJECT-TYPE SYNTAX Unsigned32 (0..83) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk Group number. 0 is the first trunk group." ::= {acPMSIPTel2IPTrunkGroupEstablishedCallsEntry 1} acPMSIPTel2IPTrunkGroupEstablishedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPTel2IPTrunkGroupEstablishedCallsEntry 2} acPMSIPTel2IPTrunkGroupEstablishedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPTel2IPTrunkGroupEstablishedCallsEntry 3} -- **************************************** -- acPMSIPIP2TelTrunkGroupEstablishedCalls table declaration -- **************************************** acPMSIPIP2TelTrunkGroupEstablishedCallsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcPMSIPIP2TelTrunkGroupEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Number of IP2Tel established calls per trunk group." ::= {acPMSIP 16} -- **************************************** -- acPMSIPIP2TelTrunkGroupEstablishedCalls table entry -- **************************************** acPMSIPIP2TelTrunkGroupEstablishedCallsEntry OBJECT-TYPE SYNTAX AcPMSIPIP2TelTrunkGroupEstablishedCallsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX {acPMSIPIP2TelTrunkGroupEstablishedCallsGroupNum,acPMSIPIP2TelTrunkGroupEstablishedCallsInterval} ::= {acPMSIPIP2TelTrunkGroupEstablishedCallsTable 1} -- **************************************** -- acPMSIPIP2TelTrunkGroupEstablishedCalls TABLE -- **************************************** AcPMSIPIP2TelTrunkGroupEstablishedCallsEntry ::= SEQUENCE { acPMSIPIP2TelTrunkGroupEstablishedCallsGroupNum Unsigned32, acPMSIPIP2TelTrunkGroupEstablishedCallsInterval Unsigned32, acPMSIPIP2TelTrunkGroupEstablishedCallsVal Counter32 } acPMSIPIP2TelTrunkGroupEstablishedCallsGroupNum OBJECT-TYPE SYNTAX Unsigned32 (0..83) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trunk Group number. 0 is the first trunk group." ::= {acPMSIPIP2TelTrunkGroupEstablishedCallsEntry 1} acPMSIPIP2TelTrunkGroupEstablishedCallsInterval OBJECT-TYPE SYNTAX Unsigned32 (0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Interval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last." ::= {acPMSIPIP2TelTrunkGroupEstablishedCallsEntry 2} acPMSIPIP2TelTrunkGroupEstablishedCallsVal OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Value of gauge or counter." ::= {acPMSIPIP2TelTrunkGroupEstablishedCallsEntry 3} END