-- ================================================================= -- Copyright (c) 2004-2012 Hangzhou H3C Tech. Co., Ltd. All rights reserved. -- -- Description: description of entity extend properties. -- Reference: -- History V2.8 -- V1.0 Created by weixinzhe, Thursday, April 22, 2004 at 18:26:02 -- V1.1 modified by yelinhui, add h3cEntityExtMacAddress -- V1.2 modified by panxidong, add h3cEntityExtErrorStatus -- V1.3 2004-10-12 updated by gaolong -- Remove BITS from IMPORTS -- V1.4 2005-02-25 modified by longyin -- Add error status stackPortBlocked(22) and stackPortFailed(23) -- for h3cEntityExtErrorStatus -- V1.5 2006-05-16 modified by wangsihai -- Add error status sensorError(81) in h3cEntityExtErrorStatus -- V1.6 2006-07-03 modified by lifengguang -- Add h3cEntityExtManuTable -- V1.7 2007-09-21 modified by lifengguang -- Add notification object h3cEntityExtSFPAlarmOn and h3cEntityExtSFPAlarmOff -- Add h3cEntityExtPowerTable -- V1.8 2007-11-19 modified by jinyi -- Add h3cEntityExtCpuMaxUsage -- V1.9 2008-02-27 modified by lifengguang -- Add Trap nodes: h3cEntityExtSFPPhony -- V2.0 2008-07-11 modified by lisong -- Add h3cProcessTable -- Add notification object h3cEntityInsert and h3cEntityRemove -- V2.1 2008-07-14 modified by lifengguang -- Add error status hardwareFaulty(91) in h3cEntityExtErrorStatus -- Add Trap nodes: h3cEntityExtForcedPowerOff and h3cEntityExtForcedPowerOn -- Add Trap nodes: h3cEntityExtFaultAlarmOn and h3cEntityExtFaultAlarmOff -- V2.2 2008-10-24 modified by lifengguang -- Add nodes h3cEntityExtLowerTemperatureThreshold and -- h3cEntityExtShutdownTemperatureThreshold in h3cEntityExtStateTable -- Add trap nodes h3cEntityExtResourceLack and h3cEntityExtResourceEnough -- in h3cEntityExtTrapsPrefix -- Add trap nodes h3cEntityExtTemperatureLower, h3cEntityExtTemperatureTooUp -- and h3cEntityExtTemperatureNormal in h3cEntityExtTrapsPrefix -- V2.3 2009-04-07 Added trap nodes h3cEntityExternalAlarmOccur and -- h3cEntityExternalAlarmRecover -- v2.4 2009-05-05 Added h3cEntityExtCpuAvgUsage, h3cEntityExtMemAvgUsage, -- h3cEntityExtPhyMemSize, h3cEntityExtMemType, h3cEntityExtPhyCpuFrequency, -- h3cEntityExtFirstUsedDate, -- h3cEntityExtCpuUsageThresholdRecover, h3cEntityExtMemUsageThresholdRecover -- V2.5 2010-08-09 -- Added h3cEntityExtShutdownLowerTemperatureThreshold, -- h3cEntityExtCriticalLowerTemperatureThreshold, -- h3cEntityExtCritLowerTempThresholdNotification and -- h3cEntityExtTemperatureTooLow by zhanglei 06807. -- Added h3cEntityExtMemAllocatedFailed, h3cEntityExtECCParityAlarm, -- h3cEntityExtTrapDescription, h3cEntityExtECCParityAlarmStatus -- by zhangqingjun 02357. -- Modified description of h3cEntityExtPhyMemSize by haoyan 06611. -- V2.6 2010-12-06 -- Added h3cEntityExtFanDirectionNotPreferred, h3cEntityExtFanDirectionNotAccord -- by lifengguang 03035. -- V2.7 2011-04-06 -- Added h3cEntityExtSFPInvalid, h3cEntityExtSFPInvalidNow and -- h3cEntityExtSFPInvalidInDays by songhao 02718. -- Changed SYNTAX of h3cEntityExtMemSize and h3cEntityExtPhyMemSize -- from Integer32 to Unsigned32 by songhao 02718. -- V2.8 2011-08-30 -- Added h3cEntityExtCpuUsageRecoverThreshold; -- Added h3cEntityExtCpuUsageRecoverThreshold to h3cEntityExtCpuUsageThresholdNotfication and -- h3cEntityExtCpuUsageThresholdRecover by shuaixiaojuan 04117. -- Added h3cEntityExtFirstTrapTime by duyanbing 04404. -- ================================================================= A3COM-HUAWEI-ENTITY-EXT-MIB DEFINITIONS ::= BEGIN IMPORTS h3cCommon FROM A3COM-HUAWEI-OID-MIB OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP FROM SNMPv2-CONF OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32, Unsigned32, Gauge32, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, MacAddress, DateAndTime, DisplayString FROM SNMPv2-TC SnmpAdminString FROM SNMP-FRAMEWORK-MIB entPhysicalIndex, entPhysicalName, entPhysicalDescr FROM ENTITY-MIB; h3cEntityExtend MODULE-IDENTITY LAST-UPDATED "201111260000Z" ORGANIZATION "Hangzhou H3C Technologies Co., Ltd." CONTACT-INFO "Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China http://www.h3c.com Zip: 100085" DESCRIPTION "The private MIB file includes the general extent information of the device." ::= { h3cCommon 6 } H3cAdminState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The administrative state for this object, and it is possible to set the state when needed. A value of locked means the resource is administratively prohibited from use. A value of shuttingDown means that usage is administratively limited to current instances of use. A value of unlocked means the resource is not administratively prohibited from use." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported(1), locked(2), shuttingDown(3), unlocked(4) } H3cOperState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Represents the possible values of operational states. A value of disabled means the resource is totally inoperable. A value of enabled means the resource is partially or fully operable." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported (1), disabled(2), enabled(3), dangerous(4) } H3cAlarmStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Represents the possible values of alarm status. When no bits of this attribute are set, then none of the status conditions described below are present. When the value of under repair is set, the resource is currently being repaired. When the value of critical is set, one or more critical alarms are active against the resource. When the value of major is set, one or more major alarms are active against the resource. When the value of minor is set, one or more minor alarms are active against the resource. When the value of warning is set, one or more warning alarms are active against the resource. When the value of indeterminate is set, one or more alarms of indeterminate severity are active against the resource. When the value of alarm outstanding is set, one or more alarms is active against the resource. The fault may or may not be disabling." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX BITS { notSupported (0), underRepair(1), critical(2), major(3), minor(4), alarmOutstanding(5), warning (6), -- Not defined in X.731 indeterminate (7) -- Not defined in X.731 } H3cStandbyStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION " Represents the possible values of standby status. A value of hotStandby means the resource is not providing service, but is will be immediately able to take over the role of the resource to be backed-up, without the need for initialization activity, and will contain the same information as the resource to be backed up. A value of coldStandy means that the resource is to back-up another resource, but will not be immediately able to take over the role of a resource to be backed up, and will require some initialization activity. A value of providingService means the resource is providing service." REFERENCE "ITU Recommendation X.731, 'Information Technology - Open Systems Interconnection - System Management: State Management Function', 1992" SYNTAX INTEGER { notSupported (1), hotStandby(2), coldStandby(3), providingService(4) } h3cEntityExtObjects OBJECT IDENTIFIER ::= { h3cEntityExtend 1 } -- MIB contains four groups h3cEntityExtState OBJECT IDENTIFIER ::= { h3cEntityExtObjects 1 } h3cEntityExtStateTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEntityExtStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not include all the object in this table, because of the entity need not some of the information here." ::= { h3cEntityExtState 1 } h3cEntityExtStateEntry OBJECT-TYPE SYNTAX H3cEntityExtStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about a particular physical entity." INDEX { h3cEntityExtPhysicalIndex } ::= { h3cEntityExtStateTable 1 } H3cEntityExtStateEntry ::= SEQUENCE { h3cEntityExtPhysicalIndex Integer32, h3cEntityExtAdminStatus H3cAdminState, h3cEntityExtOperStatus H3cOperState, h3cEntityExtStandbyStatus H3cStandbyStatus, h3cEntityExtAlarmLight H3cAlarmStatus, h3cEntityExtCpuUsage Integer32, h3cEntityExtCpuUsageThreshold Integer32, h3cEntityExtMemUsage Integer32, h3cEntityExtMemUsageThreshold Integer32, h3cEntityExtMemSize Unsigned32, h3cEntityExtUpTime Integer32, h3cEntityExtTemperature Integer32, h3cEntityExtTemperatureThreshold Integer32, h3cEntityExtVoltage Integer32, h3cEntityExtVoltageLowThreshold Integer32, h3cEntityExtVoltageHighThreshold Integer32, h3cEntityExtCriticalTemperatureThreshold Integer32, h3cEntityExtMacAddress MacAddress, h3cEntityExtErrorStatus INTEGER, h3cEntityExtCpuMaxUsage Integer32, h3cEntityExtLowerTemperatureThreshold Integer32, h3cEntityExtShutdownTemperatureThreshold Integer32, h3cEntityExtPhyMemSize Unsigned32, h3cEntityExtPhyCpuFrequency Integer32, h3cEntityExtFirstUsedDate DateAndTime, h3cEntityExtCpuAvgUsage Integer32, h3cEntityExtMemAvgUsage Integer32, h3cEntityExtMemType OCTET STRING, h3cEntityExtCriticalLowerTemperatureThreshold Integer32, h3cEntityExtShutdownLowerTemperatureThreshold Integer32, h3cEntityExtCpuUsageRecoverThreshold Integer32 } h3cEntityExtPhysicalIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of h3cEntityExtStateTable. This index is identical to entPhysicalIndex in ENTITY-MIB" ::= { h3cEntityExtStateEntry 1 } h3cEntityExtAdminStatus OBJECT-TYPE SYNTAX H3cAdminState MAX-ACCESS read-write STATUS current DESCRIPTION "The administrative state for this object." ::= { h3cEntityExtStateEntry 2 } h3cEntityExtOperStatus OBJECT-TYPE SYNTAX H3cOperState MAX-ACCESS read-only STATUS current DESCRIPTION "The operate state for this object." ::= { h3cEntityExtStateEntry 3 } h3cEntityExtStandbyStatus OBJECT-TYPE SYNTAX H3cStandbyStatus MAX-ACCESS read-only STATUS current DESCRIPTION "This object is used for monitoring standby status. Not all entities support this object." ::= { h3cEntityExtStateEntry 4 } h3cEntityExtAlarmLight OBJECT-TYPE SYNTAX H3cAlarmStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm status for this entity. It does not include the severity of alarms raised on child components. In this condition, there will be a alarm light on the entity, the object should have the same status with it." ::= { h3cEntityExtStateEntry 5 } h3cEntityExtCpuUsage OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The CPU usage for this entity. Generally, the CPU usage will calculate the overall CPU usage on the entity, and it is not sensible with the number of CPU on the entity." ::= { h3cEntityExtStateEntry 6 } h3cEntityExtCpuUsageThreshold OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the CPU usage. When the CPU usage exceeds the threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 7 } h3cEntityExtMemUsage OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The memory usage for the entity. This object indicates what percent of memory are used." ::= { h3cEntityExtStateEntry 8 } h3cEntityExtMemUsageThreshold OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the Memory usage, When the memory usage exceeds the threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 9 } h3cEntityExtMemSize OBJECT-TYPE SYNTAX Unsigned32 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The size of memory for the entity." ::= { h3cEntityExtStateEntry 10 } h3cEntityExtUpTime OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The uptime for the entity. The meaning of uptime is when the entity is up, and the value of the object will add 1 seconds while the entity is running." ::= { h3cEntityExtStateEntry 11 } h3cEntityExtTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature for the entity." ::= { h3cEntityExtStateEntry 12 } h3cEntityExtTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the temperature. When the temperature exceeds the threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 13 } h3cEntityExtVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage for the entity." ::= { h3cEntityExtStateEntry 14 } h3cEntityExtVoltageLowThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The low-threshold for the voltage. When voltage is lower than low-threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 15 } h3cEntityExtVoltageHighThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The high-threshold for the voltage. When voltage greater than high-threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 16 } h3cEntityExtCriticalTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The threshold for the critical Temperature. When temperature exceeds the critical temperature, a notification will be sent." ::= { h3cEntityExtStateEntry 17 } h3cEntityExtMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC Address of the entity." ::= { h3cEntityExtStateEntry 18 } h3cEntityExtErrorStatus OBJECT-TYPE SYNTAX INTEGER { notSupported(1), normal(2), postFailure(3), entityAbsent(4), poeError(11), stackError(21), stackPortBlocked(22), stackPortFailed(23), sfpRecvError(31), sfpSendError(32), sfpBothError(33), fanError (41), psuError(51), rpsError(61), moduleFaulty(71), sensorError(81), hardwareFaulty(91) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicate the error state of this entity object. Now it only supports Port, general power supply, RPS power supply and board/Subcard. It may have one of these values. The following four values can be used for all kinds of entities. notSupported(1) means this entity can not support this function. normal(2) means the statement of this entity is normal. for ports, it doesn't differentiate 10M/s, 100M/s, 1000M/s, duplex and half-duplex. For fan, power supply and board-Subcard, it means their states are normal. postFailure(3) means the entity fails to POST. entityAbsent(4) means the entity is absent now. The following values is depended on the entity . For Port entities, it may have the following values. If its POST is failure, then the value of the instance will be postFailure(3), otherwise the value will be normal(2). If enable power supply over Ethernet on this port is failure, the value of this instance will be poeError(11), otherwise it will be normal(2). For stack port, if it connects to another stack port normally, and these two units merge into one stack, then the value of this instance will be normal(2). If something wrong occurs and the unit can not merge into stack, the value of this instance will be stackPortFailed(23). If the stack port forms resilient daisy chain with another stack port on the other unit, the value of this instance will be stackPortBlocked(22). For SFP ports, if it fail to receive, the value of this instance will be sfpRecvError(31), if it fail to send, the value is sfpSendError(32), if it fail to send and receive, the value is sfpBothError(33), otherwise it will be normal(2). fanError(41) means that the fan stops working. psuError(51) means that the Power Supply Unit is in the state of fault. rpsError(61) means the RPS is in the state of fault. moduleFaulty(71) means the Module is in the state of fault. sensorError(81) means the sensor is in the state of fault. hardwareFaulty(91) means the hardware of specified entity is in the state of fault. NMS must be compatible with the states which may be added in the future." ::= { h3cEntityExtStateEntry 19 } h3cEntityExtCpuMaxUsage OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximal CPU usage for the entity in the period of time." ::= { h3cEntityExtStateEntry 20 } h3cEntityExtLowerTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the lower Temperature. When temperature runs under the threshold, a notification will be sent." ::= { h3cEntityExtStateEntry 21 } h3cEntityExtShutdownTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the shutdown Temperature. When temperature exceeds the threshold, a notification will be sent and the entity will be shutdown." ::= { h3cEntityExtStateEntry 22 } h3cEntityExtPhyMemSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The memory size of entity. This is the physical attribute of entity." ::= { h3cEntityExtStateEntry 23 } h3cEntityExtPhyCpuFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The CPU frequency of entity. Unit of measure is MHZ." ::= { h3cEntityExtStateEntry 24 } h3cEntityExtFirstUsedDate OBJECT-TYPE SYNTAX DateAndTime (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The first used date of the entity." ::= { h3cEntityExtStateEntry 25 } h3cEntityExtCpuAvgUsage OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The average CPU usage for the entity in a period of time." ::= { h3cEntityExtStateEntry 26 } h3cEntityExtMemAvgUsage OBJECT-TYPE SYNTAX Integer32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The average memory usage for the entity in a period of time." ::= { h3cEntityExtStateEntry 27 } h3cEntityExtMemType OBJECT-TYPE SYNTAX OCTET STRING(SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The memory type of entity." ::= { h3cEntityExtStateEntry 28 } h3cEntityExtCriticalLowerTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the critical Temperature. When temperature exceeds the critical lower temperature, a notification will be sent." ::= { h3cEntityExtStateEntry 29 } h3cEntityExtShutdownLowerTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The threshold for the shutdown Temperature. When temperature exceeds the lower threshold, a notification will be sent and the entity will be shutdown." ::= { h3cEntityExtStateEntry 30 } h3cEntityExtCpuUsageRecoverThreshold OBJECT-TYPE SYNTAX Integer32 (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "The recover threshold for the CPU usage. When the CPU usage falls down to the threshold, a notification is sent. The h3cEntityExtCpuUsageRecoverThreshold must be less than or equal to the h3cEntityExtCpuUsageThreshold." DEFVAL { 100 } ::= { h3cEntityExtStateEntry 31 } h3cEntityExtManu OBJECT IDENTIFIER ::= { h3cEntityExtObjects 2 } h3cEntityExtManuTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEntityExtManuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table about device manufacture information." ::= { h3cEntityExtManu 1 } h3cEntityExtManuEntry OBJECT-TYPE SYNTAX H3cEntityExtManuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The device manufacture information about a particular physical entity." INDEX { h3cEntityExtManuPhysicalIndex } ::= { h3cEntityExtManuTable 1 } H3cEntityExtManuEntry ::= SEQUENCE { h3cEntityExtManuPhysicalIndex Integer32, h3cEntityExtManuSerialNum SnmpAdminString, h3cEntityExtManuBuildInfo SnmpAdminString, h3cEntityExtManuBOM SnmpAdminString, h3cEntityExtMacAddressCount Unsigned32 } h3cEntityExtManuPhysicalIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of h3cEntityExtManuTable. This index is identical to entPhysicalIndex in ENTITY-MIB." ::= { h3cEntityExtManuEntry 1 } h3cEntityExtManuSerialNum OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Manufacture serial number. The manufacture serial number of the entity such as chassis, module, and so on. It is got from the device when manufacturing. For low level box-device, the manufacture serial number is the device-number of System Control Board(SCB for short), it is written into the SCB directly; for middle level or high level frame-device, the manufacture serial number is the device-numbers of SCB and Service Board, because the SCB, Service Board and chassis are separate to sale and the device-number of chassis can not be written into board." ::= { h3cEntityExtManuEntry 2 } h3cEntityExtManuBuildInfo OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Device version information. The device version information of the entity such as chassis, module, and so on. It consists of software version information and hardware version information." ::= { h3cEntityExtManuEntry 3 } h3cEntityExtManuBOM OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "Device BOM code. The device BOM code of the entity such as chassis, module, and so on. It is the component code of ERP system, which can be disassembled from device-number." ::= { h3cEntityExtManuEntry 4 } h3cEntityExtMacAddressCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address count. The count of MAC addresses of the entity, such as chassis, module, or port, and so on." ::= { h3cEntityExtManuEntry 5 } h3cEntityExtPower OBJECT IDENTIFIER ::= { h3cEntityExtObjects 3 } h3cEntityExtPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEntityExtPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the power information of all the physical entity on the device, such as the fans, the subcards, the boards, etc." ::= { h3cEntityExtPower 1 } h3cEntityExtPowerEntry OBJECT-TYPE SYNTAX H3cEntityExtPowerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entity power information about a particular physical entity." INDEX { h3cEntityExtPowerPhysicalIndex } ::= { h3cEntityExtPowerTable 1 } H3cEntityExtPowerEntry ::= SEQUENCE { h3cEntityExtPowerPhysicalIndex Integer32, h3cEntityExtNominalPower Gauge32, h3cEntityExtCurrentPower Gauge32, h3cEntityExtAveragePower Integer32, h3cEntityExtPeakPower Integer32 } h3cEntityExtPowerPhysicalIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of h3cEntityExtPowerTable. This index is identical to entPhysicalIndex in ENTITY-MIB." ::= { h3cEntityExtPowerEntry 1 } h3cEntityExtNominalPower OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal power of the entity expressed in milliWatts." ::= { h3cEntityExtPowerEntry 2 } h3cEntityExtCurrentPower OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The measured usage power of the entity expressed in milliWatts." ::= { h3cEntityExtPowerEntry 3 } h3cEntityExtAveragePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The average power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned." ::= { h3cEntityExtPowerEntry 4 } h3cEntityExtPeakPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The peak power consumed by the entity expressed in milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned." ::= { h3cEntityExtPowerEntry 5 } -- Process Table h3cProcessObjects OBJECT IDENTIFIER ::= { h3cEntityExtObjects 4 } h3cProcessTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cProcessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Table describes the information about a particular process, namely a task." ::= { h3cProcessObjects 1 } h3cProcessEntry OBJECT-TYPE SYNTAX H3cProcessEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The information about a particular process, namely a task." INDEX { h3cProcessID } ::= { h3cProcessTable 1 } H3cProcessEntry ::= SEQUENCE { h3cProcessID Unsigned32, h3cProcessName DisplayString, h3cProcessUtil5Min Unsigned32 } h3cProcessID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the identifier of process, namely task ID in system." ::= { h3cProcessEntry 1 } h3cProcessName OBJECT-TYPE SYNTAX DisplayString(SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the process name." ::= { h3cProcessEntry 2 } h3cProcessUtil5Min OBJECT-TYPE SYNTAX Unsigned32(0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "This object provides a general idea of how busy a process caused the processor to be over a 5 minute period. The ratio is calculated by the overall CPU usage caused by the process." ::= { h3cProcessEntry 3 } -- End h3cEntityExtTraps OBJECT IDENTIFIER ::= { h3cEntityExtend 2 } h3cEntityExtTrapsPrefix OBJECT IDENTIFIER ::= { h3cEntityExtTraps 0 } h3cEntityExtTrapsInfor OBJECT IDENTIFIER ::= { h3cEntityExtTraps 1 } h3cEntityExtTemperatureThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtTemperature, h3cEntityExtTemperatureThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The h3cEntityExtTemperatureThresholdNotification indicates the temperature exceeded the threshold. In this condition, user should check the status and the environment of the entity, sometimes it happens because of the failure of air-condition." ::= { h3cEntityExtTrapsPrefix 1 } h3cEntityExtVoltageLowThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtVoltage, h3cEntityExtVoltageLowThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The h3cEntityExtVoltageLowThresholdNotification indicates the voltage is lower than the threshold. If the voltage is lower too much than the entity needs, the entity will halt." ::= { h3cEntityExtTrapsPrefix 2 } h3cEntityExtVoltageHighThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtVoltage, h3cEntityExtVoltageHighThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The h3cEntityExtVoltageHighThresholdNotification indicates the voltage is higher than the threshold. If the voltage is higher too much than the entity needs, The entity may be damaged by the high voltage." ::= { h3cEntityExtTrapsPrefix 3 } h3cEntityExtCpuUsageThresholdNotfication NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtCpuUsage, h3cEntityExtCpuUsageThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight, h3cEntityExtCpuUsageRecoverThreshold, h3cEntityExtFirstTrapTime } STATUS current DESCRIPTION "The h3cEntityExtCpuUsageThresholdNotfication indicates the entity is overloaded." ::= { h3cEntityExtTrapsPrefix 4 } h3cEntityExtMemUsageThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtMemUsage, h3cEntityExtMemUsageThreshold, h3cEntityExtMemSize, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight, h3cEntityExtFirstTrapTime } STATUS current DESCRIPTION "The h3cEntityExtMemUsageThresholdNotification indicates the entity is overloaded." ::= { h3cEntityExtTrapsPrefix 5 } h3cEntityExtOperEnabled NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates the entity is operable at present." ::= { h3cEntityExtTrapsPrefix 6 } h3cEntityExtOperDisabled NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates the entity is not operable at present." ::= { h3cEntityExtTrapsPrefix 7 } h3cEntityExtCriticalTemperatureThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtTemperature, h3cEntityExtCriticalTemperatureThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The h3cEntityExtCriticalTemperatureThresholdNotification indicates the temperature exceeds the critical temperature. In this condition, user should check the status and the environment of the entity, sometimes it happens because of the failure of air-condition." ::= { h3cEntityExtTrapsPrefix 8 } h3cEntityExtSFPAlarmOn NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtErrorStatus, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap is generated when the SFP module fails or runs abnormally for some particular reason." ::= { h3cEntityExtTrapsPrefix 9 } h3cEntityExtSFPAlarmOff NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtErrorStatus, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap is generated when the SFP module restores to normal status." ::= { h3cEntityExtTrapsPrefix 10 } h3cEntityExtSFPPhony NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "This module is NOT sold by authorized manufacturer. The normal function of the device or assume the maintenance responsibility thereof will NOT be guaranteed. The trap is generated periodically after a phony module has been found." ::= { h3cEntityExtTrapsPrefix 11 } h3cEntityInsert NOTIFICATION-TYPE OBJECTS { entPhysicalDescr, h3cEntityExtAdminStatus, h3cEntityExtOperStatus } STATUS current DESCRIPTION "The trap is generated when a removeable entity inserting to device." ::= { h3cEntityExtTrapsPrefix 12 } h3cEntityRemove NOTIFICATION-TYPE OBJECTS { entPhysicalDescr, h3cEntityExtAdminStatus, h3cEntityExtOperStatus } STATUS current DESCRIPTION "The trap is generated when a removeable entity removing from device." ::= { h3cEntityExtTrapsPrefix 13 } h3cEntityExtForcedPowerOff NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates the entity is forced to power off." ::= { h3cEntityExtTrapsPrefix 14 } h3cEntityExtForcedPowerOn NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates the entity is forced to power on." ::= { h3cEntityExtTrapsPrefix 15 } h3cEntityExtFaultAlarmOn NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtErrorStatus, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates a fault occures on the specified entity." ::= { h3cEntityExtTrapsPrefix 16 } h3cEntityExtFaultAlarmOff NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtErrorStatus, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight } STATUS current DESCRIPTION "The trap indicates a fault disappears on the specified entity." ::= { h3cEntityExtTrapsPrefix 17 } h3cEntityExtResourceLack NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "The trap indicates that a kind of resource is not enough on the specified entity." ::= { h3cEntityExtTrapsPrefix 18 } h3cEntityExtResourceEnough NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "The trap indicates that the entity recovers from the status of no enough resource." ::= { h3cEntityExtTrapsPrefix 19 } h3cEntityExtTemperatureLower NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtTemperature, h3cEntityExtLowerTemperatureThreshold, h3cEntityExtAdminStatus } STATUS current DESCRIPTION "The trap indicates the temperature of a specified entity is under the lower threshold. In this condition, user should check the status and the environment of the entity, sometimes it goes wrong for some reason." ::= { h3cEntityExtTrapsPrefix 20 } h3cEntityExtTemperatureTooUp NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtTemperature, h3cEntityExtShutdownTemperatureThreshold, h3cEntityExtAdminStatus } STATUS current DESCRIPTION "The trap indicates the temperature of a specified entity exceeded the shutdown threshold. In this condition, user should check the status and the environment of the entity, sometimes it goes wrong for some reason." ::= { h3cEntityExtTrapsPrefix 21 } h3cEntityExtTemperatureNormal NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtTemperature, h3cEntityExtLowerTemperatureThreshold, h3cEntityExtTemperatureThreshold, h3cEntityExtAdminStatus } STATUS current DESCRIPTION "The trap indicates the temperature of a specified entity recover from abnormal status." ::= { h3cEntityExtTrapsPrefix 22 } h3cEntityExternalAlarmOccur NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "The trap is generated when the monitored device connected to the specified entity fails." ::= { h3cEntityExtTrapsPrefix 23 } h3cEntityExternalAlarmRecover NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "The trap is generated when the failed device connected to the specified entity returns to normal." ::= { h3cEntityExtTrapsPrefix 24 } h3cEntityExtCpuUsageThresholdRecover NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtCpuUsage, h3cEntityExtCpuUsageThreshold, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight, h3cEntityExtCpuUsageRecoverThreshold, h3cEntityExtFirstTrapTime } STATUS current DESCRIPTION "The trap indicates the CPU usage descends the threshold." ::= { h3cEntityExtTrapsPrefix 25 } h3cEntityExtMemUsageThresholdRecover NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtMemUsage, h3cEntityExtMemUsageThreshold, h3cEntityExtMemSize, h3cEntityExtAdminStatus, h3cEntityExtAlarmLight, h3cEntityExtFirstTrapTime } STATUS current DESCRIPTION "The trap indicates the memory usage descends the threshold." ::= { h3cEntityExtTrapsPrefix 26 } h3cEntityExtMemAllocatedFailed NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtTrapDescription } STATUS current DESCRIPTION "The trap indicates the memory allocated failed." ::= { h3cEntityExtTrapsPrefix 27 } h3cEntityExtECCParityAlarm NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtECCParityAlarmStatus, h3cEntityExtTrapDescription } STATUS current DESCRIPTION "The trap indicates the ECC(Error Correction Code) parity error alarm." ::= { h3cEntityExtTrapsPrefix 28 } h3cEntityExtCritLowerTempThresholdNotification NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtTemperature, h3cEntityExtCriticalLowerTemperatureThreshold } STATUS current DESCRIPTION "The h3cEntityExtCritLowerTempThresholdNotification indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity will halt." ::= { h3cEntityExtTrapsPrefix 29 } h3cEntityExtTemperatureTooLow NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtTemperature, h3cEntityExtShutdownLowerTemperatureThreshold } STATUS current DESCRIPTION "The h3cEntityExtTemperatureTooLow indicates the temperature is lower than the threshold. If the temperature is lower too much than the entity needs, the entity halts now." ::= { h3cEntityExtTrapsPrefix 30 } h3cEntityExtFanDirectionNotPreferred NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "This trap indicates the specified fan's direction does not accord with preferred. The two parameters indicate the entity index and physical name of fan." ::= { h3cEntityExtTrapsPrefix 31 } h3cEntityExtFanDirectionNotAccord NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "This trap indicates the direction of fans does not accord with each other. The two parameters indicate the parent entity of the fans." ::= { h3cEntityExtTrapsPrefix 32 } h3cEntityExtSFPInvalid NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName, h3cEntityExtSFPInvalidInDays } STATUS current DESCRIPTION "The transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transceiver. The transceiver module will be invalidated in days. Please replace it with a compatible one as soon as possible. The trap is generated periodically after a phony transceiver module has been found." ::= { h3cEntityExtTrapsPrefix 33 } h3cEntityExtSFPInvalidNow NOTIFICATION-TYPE OBJECTS { h3cEntityExtPhysicalIndex, entPhysicalName } STATUS current DESCRIPTION "This transceiver module is not compatible with the interface card. The authorized manufacturer therefore shall NOT guarantee the normal function of the transceiver. The trap is generated after a phony transceiver module has been found." ::= { h3cEntityExtTrapsPrefix 34 } h3cEntityExtTrapDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE (0..255)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The information of trap." ::= { h3cEntityExtTrapsInfor 1 } h3cEntityExtECCParityAlarmStatus OBJECT-TYPE SYNTAX INTEGER { other(1), l1cache(2), -- cpu l1 data cache err l2cache(3), -- cpu l2 data cache err sdram(4), -- sdram err for cpu mac(5), -- mac err tcam(6), -- tcam err ingressbuffer(7), -- IB err egressbuffer(8), -- EB err lpm(9), -- lpm err controlmemory(10) -- controlmemory err } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "ECC parity error." ::= { h3cEntityExtTrapsInfor 2 } h3cEntityExtSFPInvalidInDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The days when the transceiver module is still valid, but after those days, it will be invaldated." ::= { h3cEntityExtTrapsInfor 3 } h3cEntityExtFirstTrapTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Represents the first trap time." ::= { h3cEntityExtTrapsInfor 4 } -- Conformance and Compliance h3cEntityExtConformance OBJECT IDENTIFIER ::= { h3cEntityExtend 3 } h3cEntityExtCompliances OBJECT IDENTIFIER ::= { h3cEntityExtConformance 1 } -- this module h3cEntityExtCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for systems supporting this MIB." MODULE -- this module MANDATORY-GROUPS { h3cEntityExtGroup, h3cEntityExtNotificationGroup, h3cEntityExtManuGroup, h3cEntityExtPowerGroup } OBJECT h3cEntityExtAdminStatus MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT h3cEntityExtCpuUsageThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT h3cEntityExtMemUsageThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT h3cEntityExtTemperatureThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT h3cEntityExtVoltageLowThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." OBJECT h3cEntityExtVoltageHighThreshold MIN-ACCESS read-only DESCRIPTION "Write access is not required." ::= { h3cEntityExtCompliances 1 } h3cEntityExtGroups OBJECT IDENTIFIER ::= { h3cEntityExtConformance 2 } h3cEntityExtGroup OBJECT-GROUP OBJECTS { h3cEntityExtPhysicalIndex, h3cEntityExtAdminStatus, h3cEntityExtOperStatus, h3cEntityExtStandbyStatus, h3cEntityExtAlarmLight, h3cEntityExtCpuUsage, h3cEntityExtCpuUsageThreshold, h3cEntityExtMemUsage, h3cEntityExtMemUsageThreshold, h3cEntityExtMemSize, h3cEntityExtUpTime, h3cEntityExtTemperature, h3cEntityExtTemperatureThreshold, h3cEntityExtVoltage, h3cEntityExtVoltageLowThreshold, h3cEntityExtVoltageHighThreshold, h3cEntityExtCriticalTemperatureThreshold, h3cEntityExtMacAddress, h3cEntityExtErrorStatus, h3cEntityExtCpuMaxUsage, h3cEntityExtLowerTemperatureThreshold, h3cEntityExtShutdownTemperatureThreshold, h3cEntityExtPhyMemSize, h3cEntityExtPhyCpuFrequency, h3cEntityExtFirstUsedDate, h3cEntityExtCpuAvgUsage, h3cEntityExtMemAvgUsage, h3cEntityExtMemType, h3cEntityExtCriticalLowerTemperatureThreshold, h3cEntityExtShutdownLowerTemperatureThreshold, h3cEntityExtCpuUsageRecoverThreshold } STATUS current DESCRIPTION "Entity Extend group." ::= { h3cEntityExtGroups 1 } h3cEntityExtNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { h3cEntityExtTemperatureThresholdNotification, h3cEntityExtVoltageLowThresholdNotification, h3cEntityExtVoltageHighThresholdNotification, h3cEntityExtCpuUsageThresholdNotfication, h3cEntityExtMemUsageThresholdNotification, h3cEntityExtOperEnabled, h3cEntityExtOperDisabled, h3cEntityExtCriticalTemperatureThresholdNotification, h3cEntityExtSFPAlarmOn, h3cEntityExtSFPAlarmOff, h3cEntityExtSFPPhony, h3cEntityInsert, h3cEntityRemove, h3cEntityExtForcedPowerOff, h3cEntityExtForcedPowerOn, h3cEntityExtFaultAlarmOn, h3cEntityExtFaultAlarmOff, h3cEntityExtResourceLack, h3cEntityExtResourceEnough, h3cEntityExtTemperatureLower, h3cEntityExtTemperatureTooUp, h3cEntityExtTemperatureNormal, h3cEntityExternalAlarmOccur, h3cEntityExternalAlarmRecover, h3cEntityExtCpuUsageThresholdRecover, h3cEntityExtMemUsageThresholdRecover, h3cEntityExtMemAllocatedFailed, h3cEntityExtECCParityAlarm, h3cEntityExtCritLowerTempThresholdNotification, h3cEntityExtTemperatureTooLow, h3cEntityExtFanDirectionNotPreferred, h3cEntityExtFanDirectionNotAccord, h3cEntityExtSFPInvalid, h3cEntityExtSFPInvalidNow } STATUS current DESCRIPTION "Entity Extend Notification group." ::= { h3cEntityExtGroups 2 } h3cEntityExtManuGroup OBJECT-GROUP OBJECTS { h3cEntityExtManuPhysicalIndex, h3cEntityExtManuSerialNum, h3cEntityExtManuBuildInfo, h3cEntityExtManuBOM, h3cEntityExtMacAddressCount } STATUS current DESCRIPTION "Standard Device Manufacture Information group." ::= { h3cEntityExtGroups 3 } h3cEntityExtPowerGroup OBJECT-GROUP OBJECTS { h3cEntityExtPowerPhysicalIndex, h3cEntityExtNominalPower, h3cEntityExtCurrentPower, h3cEntityExtAveragePower, h3cEntityExtPeakPower } STATUS current DESCRIPTION "Standard Entity Power Information group." ::= { h3cEntityExtGroups 4 } END