ZhoneVdsl-MIB

File: ZhoneVdsl-MIB.mib (265760 bytes)

Imported modules

HC-PerfHist-TC-MIB IF-MIB SNMP-FRAMEWORK-MIB
SNMPv2-CONF SNMPv2-SMI SNMPv2-TC
Zhone

Imported symbols

HCPerfTimeElapsed HCPerfCurrentCount HCPerfIntervalCount
ifIndex SnmpAdminString OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP transmission
Integer32 Unsigned32 Gauge32
OBJECT-TYPE MODULE-IDENTITY NOTIFICATION-TYPE
RowStatus TruthValue TEXTUAL-CONVENTION
zhoneVdsl zhoneModules

Defined Types

ZhoneVdslLineCodingType  
This data type is used as the syntax for the VDSL Line Code. Attributes with this syntax identify the line coding used. Specified as an INTEGER, the three values are: other(1) -- none of the following mcm(2) -- Multiple Carrier Modulation scm(3) -- Single Carrier Modulation
TEXTUAL-CONVENTION    
  INTEGER other(1), mcm(2), scm(3)  

ZhoneVdslLineEntity  
Identifies a transceiver as being either Vtuc or Vtur. A VDSL line consists of two transceivers, a Vtuc and a Vtur. Attributes with this syntax reference the two sides of a line. Specified as an INTEGER, the two values are: vtuc(1) -- central site transceiver vtur(2) -- remote site transceiver
TEXTUAL-CONVENTION    
  INTEGER vtuc(1), vtur(2)  

ZhoneVdslLineEntry  
SEQUENCE    
  zhoneVdslLineCoding ZhoneVdslLineCodingType
  zhoneVdslLineType INTEGER
  zhoneVdslLineConfProfile SnmpAdminString
  zhoneVdslLineAlarmConfProfile SnmpAdminString

ZhoneVdslPhysEntry  
SEQUENCE    
  zhoneVdslPhysSide ZhoneVdslLineEntity
  zhoneVdslPhysInvSerialNumber OCTET STRING
  zhoneVdslPhysInvVendorID OCTET STRING
  zhoneVdslPhysInvVersionNumber OCTET STRING
  zhoneVdslPhysCurrSnrMgn Integer32
  zhoneVdslPhysCurrAtn Gauge32
  zhoneVdslPhysCurrStatus BITS
  zhoneVdslPhysCurrOutputPwr Integer32
  zhoneVdslPhysCurrAttainableRate Gauge32
  zhoneVdslPhysCurrLineRate Gauge32
  zhoneVdslPhysCurrConnType INTEGER
  zhoneVdslPhysCurrProfile INTEGER
  zhoneVdslPhysPhyRActive TruthValue
  zhoneVdslPhysGinpActive TruthValue
  zhoneVdslPhysTransportMode INTEGER

ZhoneVdslChanEntry  
SEQUENCE    
  zhoneVdslChanInterleaveDelay Gauge32
  zhoneVdslChanCrcBlockLength Gauge32
  zhoneVdslChanCurrTxRate Gauge32
  zhoneVdslChanCurrTxSlowBurstProtect Gauge32
  zhoneVdslChanCurrTxFastFec Gauge32

ZhoneVdslPerfDataEntry  
SEQUENCE    
  zhoneVdslPerfDataValidIntervals Integer32
  zhoneVdslPerfDataInvalidIntervals Integer32
  zhoneVdslPerfDataLofs Unsigned32
  zhoneVdslPerfDataLoss Unsigned32
  zhoneVdslPerfDataLprs Unsigned32
  zhoneVdslPerfDataLols Unsigned32
  zhoneVdslPerfDataESs Unsigned32
  zhoneVdslPerfDataSESs Unsigned32
  zhoneVdslPerfDataUASs Unsigned32
  zhoneVdslPerfDataInits Unsigned32
  zhoneVdslPerfDataCurr15MinTimeElapsed Integer32
  zhoneVdslPerfDataCurr15MinLofs Unsigned32
  zhoneVdslPerfDataCurr15MinLoss Unsigned32
  zhoneVdslPerfDataCurr15MinLprs Unsigned32
  zhoneVdslPerfDataCurr15MinLols Unsigned32
  zhoneVdslPerfDataCurr15MinESs Unsigned32
  zhoneVdslPerfDataCurr15MinSESs Unsigned32
  zhoneVdslPerfDataCurr15MinUASs Unsigned32
  zhoneVdslPerfDataCurr15MinInits Unsigned32
  zhoneVdslPerfData1DayValidIntervals Integer32
  zhoneVdslPerfData1DayInvalidIntervals Integer32
  zhoneVdslPerfDataCurr1DayTimeElapsed Integer32
  zhoneVdslPerfDataCurr1DayLofs Unsigned32
  zhoneVdslPerfDataCurr1DayLoss Unsigned32
  zhoneVdslPerfDataCurr1DayLprs Unsigned32
  zhoneVdslPerfDataCurr1DayLols Unsigned32
  zhoneVdslPerfDataCurr1DayESs Unsigned32
  zhoneVdslPerfDataCurr1DaySESs Unsigned32
  zhoneVdslPerfDataCurr1DayUASs Unsigned32
  zhoneVdslPerfDataCurr1DayInits Unsigned32
  zhoneVdslPhyrRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCorrectedRetransmittedCodewords Unsigned32
  zhoneVdslPhyrUncorrectableRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr15MinRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr15MinCorrectedRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr15MinUncorrectableRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr1DayRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr1DayCorrectedRetransmittedCodewords Unsigned32
  zhoneVdslPhyrCurr1DayUncorrectableRetransmittedCodewords Unsigned32
  zhoneVdslPhyrPrev1DayRetransmittedCodewords Unsigned32
  zhoneVdslPhyrPrev1DayCorrectedRetransmittedCodewords Unsigned32
  zhoneVdslPhyrPrev1DayUncorrectableRetransmittedCodewords Unsigned32
  zhoneVdslGinpLeftrSecs Unsigned32
  zhoneVdslGinpErrorFreeBits Unsigned32
  zhoneVdslGinpMinEftr Unsigned32
  zhoneVdslGinpCurr15MinLeftrSecs Unsigned32
  zhoneVdslGinpCurr15MinErrorFreeBits Unsigned32
  zhoneVdslGinpCurr15MinMinEftr Unsigned32
  zhoneVdslGinpCurr1DayLeftrSecs Unsigned32
  zhoneVdslGinpCurr1DayErrorFreeBits Unsigned32
  zhoneVdslGinpCurr1DayMinEftr Unsigned32
  zhoneVdslGinpPrev1DayLeftrSecs Integer32
  zhoneVdslGinpPrev1DayErrorFreeBits Integer32
  zhoneVdslGinpPrev1DayMinEftr Integer32

ZhoneVdslPerfIntervalEntry  
SEQUENCE    
  zhoneVdslPerfIntervalNumber Unsigned32
  zhoneVdslPerfIntervalLofs HCPerfIntervalCount
  zhoneVdslPerfIntervalLoss HCPerfIntervalCount
  zhoneVdslPerfIntervalLprs HCPerfIntervalCount
  zhoneVdslPerfIntervalLols HCPerfIntervalCount
  zhoneVdslPerfIntervalESs HCPerfIntervalCount
  zhoneVdslPerfIntervalSESs HCPerfIntervalCount
  zhoneVdslPerfIntervalUASs HCPerfIntervalCount
  zhoneVdslPerfIntervalInits HCPerfIntervalCount

ZhoneVdslPerf1DayIntervalEntry  
SEQUENCE    
  zhoneVdslPerf1DayIntervalNumber Unsigned32
  zhoneVdslPerf1DayIntervalMoniSecs HCPerfTimeElapsed
  zhoneVdslPerf1DayIntervalLofs Unsigned32
  zhoneVdslPerf1DayIntervalLoss Unsigned32
  zhoneVdslPerf1DayIntervalLprs Unsigned32
  zhoneVdslPerf1DayIntervalLols Unsigned32
  zhoneVdslPerf1DayIntervalESs Unsigned32
  zhoneVdslPerf1DayIntervalSESs Unsigned32
  zhoneVdslPerf1DayIntervalUASs Unsigned32
  zhoneVdslPerf1DayIntervalInits Unsigned32

ZhoneVdslChanPerfDataEntry  
SEQUENCE    
  zhoneVdslChanValidIntervals Integer32
  zhoneVdslChanInvalidIntervals Integer32
  zhoneVdslChanFixedOctets Integer32
  zhoneVdslChanBadBlks Integer32
  zhoneVdslChanCurr15MinTimeElapsed Integer32
  zhoneVdslChanCurr15MinFixedOctets Integer32
  zhoneVdslChanCurr15MinBadBlks Integer32
  zhoneVdslChan1DayValidIntervals Integer32
  zhoneVdslChan1DayInvalidIntervals Integer32
  zhoneVdslChanCurr1DayTimeElapsed Integer32
  zhoneVdslChanCurr1DayFixedOctets Integer32
  zhoneVdslChanCurr1DayBadBlks Integer32

ZhoneVdslChanIntervalEntry  
SEQUENCE    
  zhoneVdslChanIntervalNumber Unsigned32
  zhoneVdslChanIntervalFixedOctets HCPerfIntervalCount
  zhoneVdslChanIntervalBadBlks HCPerfIntervalCount

ZhoneVdslChan1DayIntervalEntry  
SEQUENCE    
  zhoneVdslChan1DayIntervalNumber Unsigned32
  zhoneVdslChan1DayIntervalMoniSecs HCPerfTimeElapsed
  zhoneVdslChan1DayIntervalFixedOctets HCPerfCurrentCount
  zhoneVdslChan1DayIntervalBadBlks HCPerfCurrentCount

ZhoneVdslLineConfProfileEntry  
SEQUENCE    
  zhoneVdslLineConfProfileName SnmpAdminString
  zhoneVdslLineConfDownRateMode INTEGER
  zhoneVdslLineConfUpRateMode INTEGER
  zhoneVdslLineConfDownMaxPwr Integer32
  zhoneVdslLineConfUpMaxPwr Integer32
  zhoneVdslLineConfDownMaxSnrMgn Unsigned32
  zhoneVdslLineConfDownMinSnrMgn Unsigned32
  zhoneVdslLineConfDownTargetSnrMgn Unsigned32
  zhoneVdslLineConfUpMaxSnrMgn Unsigned32
  zhoneVdslLineConfUpMinSnrMgn Unsigned32
  zhoneVdslLineConfUpTargetSnrMgn Unsigned32
  zhoneVdslLineConfDownFastMaxDataRate Unsigned32
  zhoneVdslLineConfDownFastMinDataRate Unsigned32
  zhoneVdslLineConfDownSlowMaxDataRate Unsigned32
  zhoneVdslLineConfDownSlowMinDataRate Unsigned32
  zhoneVdslLineConfUpFastMaxDataRate Unsigned32
  zhoneVdslLineConfUpFastMinDataRate Unsigned32
  zhoneVdslLineConfUpSlowMaxDataRate Unsigned32
  zhoneVdslLineConfUpSlowMinDataRate Unsigned32
  zhoneVdslLineConfDownRateRatio Unsigned32
  zhoneVdslLineConfUpRateRatio Unsigned32
  zhoneVdslLineConfDownMaxInterDelay Unsigned32
  zhoneVdslLineConfUpMaxInterDelay Unsigned32
  zhoneVdslLineConfDownPboControl INTEGER
  zhoneVdslLineConfUpPboControl INTEGER
  zhoneVdslLineConfDownPboLevel Unsigned32
  zhoneVdslLineConfUpPboLevel Unsigned32
  zhoneVdslLineConfDeploymentScenario INTEGER
  zhoneVdslLineConfAdslPresence INTEGER
  zhoneVdslLineConfApplicableStandard INTEGER
  zhoneVdslLineConfBandPlan INTEGER
  zhoneVdslLineConfBandPlanFx Unsigned32
  zhoneVdslLineConfBandOptUsage INTEGER
  zhoneVdslLineConfUpPsdTemplate INTEGER
  zhoneVdslLineConfDownPsdTemplate INTEGER
  zhoneVdslLineConfHamBandMask BITS
  zhoneVdslLineConfCustomNotch1Start Unsigned32
  zhoneVdslLineConfCustomNotch1Stop Unsigned32
  zhoneVdslLineConfCustomNotch2Start Unsigned32
  zhoneVdslLineConfCustomNotch2Stop Unsigned32
  zhoneVdslLineConfDownTargetSlowBurst Unsigned32
  zhoneVdslLineConfUpTargetSlowBurst Unsigned32
  zhoneVdslLineConfDownMaxFastFec Unsigned32
  zhoneVdslLineConfUpMaxFastFec Unsigned32
  zhoneVdslLineConfLineType INTEGER
  zhoneVdslLineConfProfRowStatus RowStatus
  zhoneVdslLineConfTransmissionMode INTEGER
  zhoneVdslLineConfVdsl2Profile INTEGER
  zhoneVdslLineConfVdslMode INTEGER
  zhoneVdslLineConfPboElectricalOverride Integer32
  zhoneVdslLineConfAutoModeCrtrn INTEGER
  zhoneVdslLineConfNetworkTimingRef INTEGER
  zhoneVdslLineConfAdslBandMode INTEGER
  zhoneVdslLineConfAdslBandModeEndFreq Integer32
  zhoneVdslLineConfSeltEchoMeasurementTime Integer32
  zhoneVdslLineConfSeltNoiseMeasurementTime Integer32
  zhoneVdslLineConfSeltAgc Integer32
  zhoneVdslLineConfDownTrellis INTEGER
  zhoneVdslLineConfUpTrellis INTEGER
  zhoneVdslLineConfDownMaxAggregateTxPwr INTEGER
  zhoneVdslLineConfUpMaxAggregateTxPwr INTEGER
  zhoneVdslLineConfDownMaxPsd Integer32
  zhoneVdslLineConfUpMaxPsd Integer32
  zhoneVdslLineConfDownPsdShape INTEGER
  zhoneVdslLineConfUpPsdShape INTEGER
  zhoneVdslLineConfDownVirtualNoiseSnrMode INTEGER
  zhoneVdslLineConfUpVirtualNoiseSnrMode INTEGER
  zhoneVdslLineConfDownErasureDetectionFast INTEGER
  zhoneVdslLineConfUpErasureDetectionFast INTEGER
  zhoneVdslLineConfDownErasureDetectionInterleave INTEGER
  zhoneVdslLineConfUpErasureDetectionInterleave INTEGER
  zhoneVdslLineConfDownGhsA43TonePwr INTEGER
  zhoneVdslLineConfDownGhsB43TonePwr INTEGER
  zhoneVdslLineConfDownGhsA43cTonePwr INTEGER
  zhoneVdslLineConfDownGhsV43TonePwr INTEGER
  zhoneVdslLineConfDownGhsA43TonePwrMaxLvl Integer32
  zhoneVdslLineConfDownGhsB43TonePwrMaxLvl Integer32
  zhoneVdslLineConfDownGhsA43cTonePwrMaxLvl Integer32
  zhoneVdslLineConfDownGhsV43TonePwrMaxLvl Integer32
  zhoneVdslLineConfDownRsCoding INTEGER
  zhoneVdslLineConfUpRsCoding INTEGER
  zhoneVdslLineConfUpPboPsdTemplate INTEGER
  zhoneVdslLineConfUpPboPsdParamA1 Integer32
  zhoneVdslLineConfUpPboPsdParamA2 Integer32
  zhoneVdslLineConfUpPboPsdParamB1 Integer32
  zhoneVdslLineConfUpPboPsdParamB2 Integer32
  zhoneVdslLineConfDownDownshiftSnrMgn Integer32
  zhoneVdslLineConfDownUpshiftSnrMgn Integer32
  zhoneVdslLineConfDownMinDownshiftTime Integer32
  zhoneVdslLineConfDownMinUpshiftTime Integer32
  zhoneVdslLineConfUpDownshiftSnrMgn Integer32
  zhoneVdslLineConfUpUpshiftSnrMgn Integer32
  zhoneVdslLineConfUpMinDownshiftTime Integer32
  zhoneVdslLineConfUpMinUpshiftTime Integer32
  zhoneVdslLineConfDownMinTxThresholdAlarm Unsigned32
  zhoneVdslLineConfUpMinTxThresholdAlarm Unsigned32
  zhoneVdslLineConfPotsBypassRelayMaxDuration INTEGER
  zhoneVdslLineConfDMTConfMode INTEGER
  zhoneVdslLineConfDownBitSwap INTEGER
  zhoneVdslLineConfUpBitSwap INTEGER
  zhoneVdslLineConfAdslAnnexMModeEnabled TruthValue
  zhoneVdslLineConfAdslAnnexMPsdMask INTEGER
  zhoneVdslLineConfUs0BoundaryTone INTEGER
  zhoneVdslLineConfDownInp INTEGER
  zhoneVdslLineConfUpInp INTEGER
  zhoneVdslLineConfDownMaxInterleavingDelay INTEGER
  zhoneVdslLineConfUpMaxInterleavingDelay INTEGER
  zhoneVdslLineConfDownPsdMaskEnable INTEGER
  zhoneVdslLineConfUpPsdMaskEnable INTEGER
  zhoneVdslLineConfDownPsdMaskSelect INTEGER
  zhoneVdslLineConfUpPsdMaskSelect INTEGER
  zhoneVdslLineEnableTrellisCoding TruthValue
  zhoneVdslLineEnableRsCoding TruthValue
  zhoneVdslLineConfPsdShape INTEGER
  zhoneVdslLineConfDownPhyRSupport INTEGER
  zhoneVdslLineConfUpPhyRSupport INTEGER
  zhoneVdslLineConfDownPhyRmaxINP INTEGER
  zhoneVdslLineConfUpPhyRmaxINP INTEGER
  zhoneVdslLineConfDownPhyRminRSoverhead INTEGER
  zhoneVdslLineConfUpPhyRminRSoverhead INTEGER
  zhoneVdslLineConfDownPhyRRtxRatio INTEGER
  zhoneVdslLineConfUpPhyRRtxRatio INTEGER
  zhoneVdslLineConfUpPboPsdParamA3 Integer32
  zhoneVdslLineConfUpPboPsdParamA4 Integer32
  zhoneVdslLineConfUpPboPsdParamB3 Integer32
  zhoneVdslLineConfUpPboPsdParamB4 Integer32
  zhoneVdslLineConfFallbackDefaultVpi Unsigned32
  zhoneVdslLineConfFallbackDefaultVci Unsigned32
  zhoneVdslLineConfDownGinpSupport INTEGER
  zhoneVdslLineConfUpGinpSupport INTEGER
  zhoneVdslLineConfDownGinpEtrMax Unsigned32
  zhoneVdslLineConfUpGinpEtrMax Unsigned32
  zhoneVdslLineConfDownGinpEtrMin Unsigned32
  zhoneVdslLineConfUpGinpEtrMin Unsigned32
  zhoneVdslLineConfDownGinpNdrMax Unsigned32
  zhoneVdslLineConfUpGinpNdrMax Unsigned32
  zhoneVdslLineConfDownGinpShineRatio Unsigned32
  zhoneVdslLineConfUpGinpShineRatio Unsigned32
  zhoneVdslLineConfDownGinpLeftrThreshold Unsigned32
  zhoneVdslLineConfUpGinpLeftrThreshold Unsigned32
  zhoneVdslLineConfDownGinpMaxDelay Unsigned32
  zhoneVdslLineConfUpGinpMaxDelay Unsigned32
  zhoneVdslLineConfDownGinpMinDelay Unsigned32
  zhoneVdslLineConfUpGinpMinDelay Unsigned32
  zhoneVdslLineConfDownGinpMin Unsigned32
  zhoneVdslLineConfUpGinpMin Unsigned32
  zhoneVdslLineConfDownGinpMinRSoverhead Unsigned32
  zhoneVdslLineConfUpGinpMinRSoverhead Unsigned32
  zhoneVdslLineConfDownGinpReinCfg Unsigned32
  zhoneVdslLineConfUpGinpReinCfg Unsigned32
  zhoneVdslLineConfDownGinpReinFreq INTEGER
  zhoneVdslLineConfUpGinpReinFreq INTEGER
  zhoneVdslLineConfDownGinpRtxMode INTEGER
  zhoneVdslLineConfUpGinpRtxMode INTEGER

ZhoneVdslLineAlarmConfProfileEntry  
SEQUENCE    
  zhoneVdslLineAlarmConfProfileName SnmpAdminString
  zhoneVdslLineAlarmConfThresh15MinLofs INTEGER
  zhoneVdslLineAlarmConfThresh15MinLoss INTEGER
  zhoneVdslLineAlarmConfThresh15MinLprs INTEGER
  zhoneVdslLineAlarmConfThresh15MinLols INTEGER
  zhoneVdslLineAlarmConfThresh15MinESs INTEGER
  zhoneVdslLineAlarmConfThresh15MinSESs INTEGER
  zhoneVdslLineAlarmConfThresh15MinUASs INTEGER
  zhoneVdslLineAlarmConfInitFailure TruthValue
  zhoneVdslLineAlarmConfProfRowStatus RowStatus
  zhoneVdslLineAlarmConfThresh1DayLofs INTEGER
  zhoneVdslLineAlarmConfThresh1DayLoss INTEGER
  zhoneVdslLineAlarmConfThresh1DayLprs INTEGER
  zhoneVdslLineAlarmConfThresh1DayLols INTEGER
  zhoneVdslLineAlarmConfThresh1DayESs INTEGER
  zhoneVdslLineAlarmConfThresh1DaySESs INTEGER
  zhoneVdslLineAlarmConfThresh1DayUASs INTEGER
  zhoneVdslLineAlarmConfThresh1DayInitFailure TruthValue

ZhoneVdslCustomNotchConfProfileEntry  
SEQUENCE    
  zhoneVdslCustomNotchConfId Unsigned32
  zhoneVdslCustomNotchConfStart Unsigned32
  zhoneVdslCustomNotchConfStop Unsigned32

ZhoneVdslVectDataEntry  
SEQUENCE    
  zhoneVdslVectDataEsDsCounter Integer32
  zhoneVdslVectDataEsUsCounter Integer32
  zhoneVdslVectDataIsDsFeValid Integer32
  zhoneVdslVectDataEsFeDsCounter Integer32

Defined Values

zhoneVdslMib 1.3.6.1.4.1.5504.6.110
The MIB module defining objects for the management of a pair of VDSL transceivers at each end of the VDSL line. Each such line has an entry in an ifTable which may include multiple transceiver lines. An agent may reside at either end of the VDSL line. However, the MIB is designed to require no management communication between them beyond that inherent in the low-level VDSL line protocol. The agent may monitor and control this protocol for its needs. VDSL lines may support optional Fast or Interleaved channels. If these are supported, additional entries corresponding to the supported channels must be created in the ifTable. Thus a VDSL line that supports both channels will have three entries in the ifTable, one for each physical, fast, and interleaved, whose ifType values are equal to vdsl(97), fast(125), and interleaved(124), respectively. The ifStackTable is used to represent the relationship between the entries. Naming Conventions: Vtuc -- (VTUC) transceiver at near (Central) end of line Vtur -- (VTUR) transceiver at Remote end of line Vtu -- One of either Vtuc or Vtur Curr -- Current Prev -- Previous Atn -- Attenuation ES -- Errored Second. SES -- Severely Errored Second UAS -- Unavailable Second LCS -- Line Code Specific Lof -- Loss of Frame Lol -- Loss of Link Los -- Loss of Signal Lpr -- Loss of Power xxxs -- Sum of Seconds in which xxx has occured (e.g., xxx = Lof, Los, Lpr, Lol) Max -- Maximum Mgn -- Margin Min -- Minimum Psd -- Power Spectral Density Snr -- Signal to Noise Ratio Tx -- Transmit Blks -- Blocks Copyright (C) The Internet Society (2004). This version of this MIB module is part of RFC 3728: see the RFC itself for full legal notices.
MODULE-IDENTITY    

zhoneVdslLineMib 1.3.6.1.4.1.5504.5.13.1
OBJECT IDENTIFIER    

zhoneVdslNotifications 1.3.6.1.4.1.5504.5.13.1.0
OBJECT IDENTIFIER    

vdslXtucPerf15MinLofsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.1
Loss of Framing 15-minute interval threshold (vdslLineAlarmConfThresh15MinLofs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinLossThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.2
Loss of Signal 15-minute interval threshold (vdslLineAlarmConfThresh15MinLoss) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinLprsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.3
Loss of Power 15-minute interval threshold (vdslLineAlarmConfThresh15MinLprs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinLolsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.4
Loss of Link 15-minute interval threshold (vdslLineAlarmConfThresh15MinLols) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinESsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.5
Errored Seconds 15-minute interval threshold (vdslLineAlarmConfThresh15MinESs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinSESsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.6
Severely Errored Seconds 15-minute interval threshold (vdslLineAlarmConfThresh15MinSESs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf15MinUASsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.7
Unavailable Seconds 15-minute interval threshold (vdslLineAlarmConfThresh15MinUASs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayLofsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.8
Loss of Framing 1-day interval threshold (vdslLineAlarmConfThresh1DayLofs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayLossThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.9
Loss of Signal 1-day interval threshold (vdslLineAlarmConfThresh1DayLoss) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayLprsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.10
Loss of Power 1-day interval threshold (vdslLineAlarmConfThresh1DayLprs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayLolsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.11
Loss of Link 1-day interval threshold (vdslLineAlarmConfThresh1DayLols) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayESsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.12
Errored Seconds 1-day interval threshold (vdslLineAlarmConfThresh1DayESs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DaySESsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.13
Severely Errored Seconds 1-day interval threshold (vdslLineAlarmConfThresh1DaySESs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucPerf1DayUASsThreshTrap 1.3.6.1.4.1.5504.5.13.1.0.14
Unavailable Seconds 1-day interval threshold (vdslLineAlarmConfThresh1DayUASs) reached.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneVdslInitFailureTrap 1.3.6.1.4.1.5504.5.13.1.0.15
Vtu initialization failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXtucMinTxThresholdAlarmFailureTrap 1.3.6.1.4.1.5504.5.13.1.0.16
This trap is thrown when the XTUC line rate syncs below the threshold rate as defined by zhoneVdslLineConfDownMinTxThresholdAlarm.
Status: current Access: read-only
NOTIFICATION-TYPE    

vdslXturMinTxThresholdAlarmFailureTrap 1.3.6.1.4.1.5504.5.13.1.0.17
This trap is thrown when the XTUR line rate syncs below the threshold rate as defined by zhoneVdslLineConfUpMinTxThresholdAlarm.
Status: current Access: read-only
NOTIFICATION-TYPE    

zhoneVdslMibObjects 1.3.6.1.4.1.5504.5.13.1.1
OBJECT IDENTIFIER    

zhoneVdslLineTable 1.3.6.1.4.1.5504.5.13.1.1.1
This table includes common attributes describing both ends of the line. It is required for all VDSL physical interfaces. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslLineEntry

zhoneVdslLineEntry 1.3.6.1.4.1.5504.5.13.1.1.1.1
An entry in the vdslLineTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslLineEntry  

zhoneVdslLineCoding 1.3.6.1.4.1.5504.5.13.1.1.1.1.1
Specifies the VDSL coding type used on this line.
Status: current Access: read-only
OBJECT-TYPE    
  ZhoneVdslLineCodingType  

zhoneVdslLineType 1.3.6.1.4.1.5504.5.13.1.1.1.1.2
Defines the type of VDSL physical line entity that exists, by defining whether and how the line is channelized. If the line is channelized, the value will be other than noChannel(1). This object defines which channel type(s) are supported. Defined values are: noChannel(1) -- no channels exist fastOnly(2) -- only fast channel exists interleavedOnly(3) -- only interleaved channel exists fastOrInterleaved(4) -- either fast or interleaved channel -- exist, but only one at a time fastAndInterleaved(5) -- both fast and interleaved channels -- exist Note that 'slow' and 'interleaved' refer to the same channel. In the case that the line is channelized, the manager can use the ifStackTable to determine the ifIndex for the associated channel(s).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noChannel(1), fastOnly(2), interleavedOnly(3), fastOrInterleaved(4), fastAndInterleaved(5)  

zhoneVdslLineConfProfile 1.3.6.1.4.1.5504.5.13.1.1.1.1.3
The value of this object identifies the row in the VDSL Line Configuration Profile Table, zhoneVdslLineConfProfileTable, which applies for this VDSL line, and channels if applicable. This object MUST be maintained in a persistent manner.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

zhoneVdslLineAlarmConfProfile 1.3.6.1.4.1.5504.5.13.1.1.1.1.4
The value of this object identifies the row in the VDSL Line Alarm Configuration Profile Table, zhoneVdslLineAlarmConfProfileTable, which applies to this VDSL line, and channels if applicable. This object MUST be maintained in a persistent manner.
Status: current Access: read-write
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

zhoneVdslPhysTable 1.3.6.1.4.1.5504.5.13.1.1.2
This table provides one row for each Vtu. Each row contains the Physical Layer Parameters table for that Vtu. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslPhysEntry

zhoneVdslPhysEntry 1.3.6.1.4.1.5504.5.13.1.1.2.1
An entry in the vdslPhysTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslPhysEntry  

zhoneVdslPhysSide 1.3.6.1.4.1.5504.5.13.1.1.2.1.1
Identifies whether the transceiver is the Vtuc or Vtur.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslLineEntity  

zhoneVdslPhysInvSerialNumber 1.3.6.1.4.1.5504.5.13.1.1.2.1.2
The vendor specific string that identifies the vendor equipment.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

zhoneVdslPhysInvVendorID 1.3.6.1.4.1.5504.5.13.1.1.2.1.3
The vendor ID code is a copy of the binary vendor identification field expressed as readable characters in hexadecimal notation.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

zhoneVdslPhysInvVersionNumber 1.3.6.1.4.1.5504.5.13.1.1.2.1.4
The vendor specific version number sent by this Vtu as part of the initialization messages. It is a copy of the binary version number field expressed as readable characters in hexadecimal notation.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..16)  

zhoneVdslPhysCurrSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.2.1.5
Noise Margin as seen by this Vtu with respect to its received signal in 0.10dB. The effective range is -31.75 to +31.75 dB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -127..127  

zhoneVdslPhysCurrAtn 1.3.6.1.4.1.5504.5.13.1.1.2.1.6
Measured difference in the total power transmitted by the peer Vtu and the total power received by this Vtu. The effective range is 0 to +63.75 dB.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..255  

zhoneVdslPhysCurrStatus 1.3.6.1.4.1.5504.5.13.1.1.2.1.7
Indicates current state of the Vtu line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There are no defects on the line. 1 lossOfFraming Vtu failure due to not receiving a valid frame. 2 lossOfSignal Vtu failure due to not receiving signal. 3 lossOfPower Vtu failure due to loss of power. 4 lossOfSignalQuality Loss of Signal Quality is declared when the Noise Margin falls below the Minimum Noise Margin, or the bit-error-rate exceeds 10^-7. 5 lossOfLink Vtu failure due to inability to link with peer Vtu. Set whenever the transceiver is in the 'Warm Start' state. 6 dataInitFailure Vtu failure during initialization due to bit errors corrupting startup exchange data. 7 configInitFailure Vtu failure during initialization due to peer Vtu not able to support requested configuration. 8 protocolInitFailure Vtu failure during initialization due to incompatible protocol used by the peer Vtu. 9 noPeerVtuPresent Vtu failure during initialization due to no activation sequence detected from peer Vtu. This is intended to supplement ifOperStatus.
Status: current Access: read-only
OBJECT-TYPE    
  BITS noDefect(0), lossOfFraming(1), lossOfSignal(2), lossOfPower(3), lossOfSignalQuality(4), lossOfLink(5), dataInitFailure(6), configInitFailure(7), protocolInitFailure(8), noPeerVtuPresent(9)  

zhoneVdslPhysCurrOutputPwr 1.3.6.1.4.1.5504.5.13.1.1.2.1.8
Measured total output power transmitted by this VTU. This is the measurement that was reported during the last activation sequence.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..160  

zhoneVdslPhysCurrAttainableRate 1.3.6.1.4.1.5504.5.13.1.1.2.1.9
Indicates the maximum currently attainable data rate in steps of 1000 bits/second by the Vtu. This value will be equal to or greater than vdslPhysCurrLineRate. Note that for SCM, the minimum and maximum data rates are equal. Note: 1 kbps = 1000 bps.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

zhoneVdslPhysCurrLineRate 1.3.6.1.4.1.5504.5.13.1.1.2.1.10
Indicates the current data rate in steps of 1000 bits/second by the Vtu. This value will be less than or equal to vdslPhysCurrAttainableRate. Note: 1 kbps = 1000 bps.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

zhoneVdslPhysCurrConnType 1.3.6.1.4.1.5504.5.13.1.1.2.1.12
Indicates current connection type. unknown(1) - could not determine connection type not-connected(2) - connection has not been established invalid(3) - unknown connection established adsl(4) - G.992.1/2 adsl2(5) - G.992.3/4 adsl2-annexm(6) - G.992.3/4 with Annex M adsl2plus(7) - G.992.5 adsl2plus-annexm(8) - G.992.5 with Annex M vdsl1(9) - G.993.1 vdsl2(10) - G.993.2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), not-connected(2), invalid(3), adsl(4), adsl2(5), adsl2-annexm(6), adsl2plus(7), adsl2plus-annexm(8), vdsl1(9), vdsl2(10)  

zhoneVdslPhysCurrProfile 1.3.6.1.4.1.5504.5.13.1.1.2.1.13
Indicates current VDSL profile being used in the connection. This object is only valid for VDSL connections.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER g993-2-8a(1), g993-2-8b(2), g993-2-8c(3), g993-2-8d(4), g993-2-12a(5), g993-2-12b(6), g993-2-17a(7), g993-2-30a(8), no-vdsl-connection(9)  

zhoneVdslPhysPhyRActive 1.3.6.1.4.1.5504.5.13.1.1.2.1.14
Phy Retransmit Rx Queue Active.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVdslPhysGinpActive 1.3.6.1.4.1.5504.5.13.1.1.2.1.15
G.INP/ITU-G.998.4 feature active
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVdslPhysTransportMode 1.3.6.1.4.1.5504.5.13.1.1.2.1.16
Transport mode, either ATM or PTM
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER atm(1), ptm(2)  

zhoneVdslChanTable 1.3.6.1.4.1.5504.5.13.1.1.3
This table provides one row for each Vtu channel. VDSL channel interfaces are those ifEntries where ifType is equal to interleave(124) or fast(125).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslChanEntry

zhoneVdslChanEntry 1.3.6.1.4.1.5504.5.13.1.1.3.1
An entry in the vdslChanTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslChanEntry  

zhoneVdslChanInterleaveDelay 1.3.6.1.4.1.5504.5.13.1.1.3.1.1
Interleave Delay for this channel. Interleave delay applies only to the interleave (slow) channel and defines the mapping (relative spacing) between subsequent input bytes at the interleaver input and their placement in the bit stream at the interleaver output. Larger numbers provide greater separation between consecutive input bytes in the output bit stream allowing for improved impulse noise immunity at the expense of payload latency. In the case where the ifType is fast(125), return a value of zero.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

zhoneVdslChanCrcBlockLength 1.3.6.1.4.1.5504.5.13.1.1.3.1.2
Indicates the length of the channel data-block on which the CRC operates.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

zhoneVdslChanCurrTxRate 1.3.6.1.4.1.5504.5.13.1.1.3.1.3
Actual transmit data rate on this channel. Note: 1 kbps = 1000 bps.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

zhoneVdslChanCurrTxSlowBurstProtect 1.3.6.1.4.1.5504.5.13.1.1.3.1.4
Actual level of impulse noise (burst) protection for an interleaved (slow) channel. This parameter is not applicable to fast channels. For fast channels, a value of zero shall be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..1275  

zhoneVdslChanCurrTxFastFec 1.3.6.1.4.1.5504.5.13.1.1.3.1.5
Actual Forward Error Correction (FEC) redundancy related overhead for a fast channel. This parameter is not applicable to an interleaved (slow) channel. For interleaved channels, a value of zero shall be returned.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32 0..50  

zhoneVdslPerfDataTable 1.3.6.1.4.1.5504.5.13.1.1.4
This table provides one row for each VDSL physical interface. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslPerfDataEntry

zhoneVdslPerfDataEntry 1.3.6.1.4.1.5504.5.13.1.1.4.1
An entry in the vdslPerfDataTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslPerfDataEntry  

zhoneVdslPerfDataValidIntervals 1.3.6.1.4.1.5504.5.13.1.1.4.1.1
Valid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslPerfDataInvalidIntervals 1.3.6.1.4.1.5504.5.13.1.1.4.1.2
Invalid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslPerfDataLofs 1.3.6.1.4.1.5504.5.13.1.1.4.1.3
Count of seconds since the unit was last reset that there was Loss of Framing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataLoss 1.3.6.1.4.1.5504.5.13.1.1.4.1.4
Count of seconds since the unit was last reset that there was Loss of Signal.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataLprs 1.3.6.1.4.1.5504.5.13.1.1.4.1.5
Count of seconds since the unit was last reset that there was Loss of Power.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataLols 1.3.6.1.4.1.5504.5.13.1.1.4.1.6
Count of seconds since the unit was last reset that there was Loss of Link.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.7
Count of Errored Seconds since the unit was last reset. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS or LOF defects.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataSESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.8
Count of Severely Errored Seconds since the unit was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataUASs 1.3.6.1.4.1.5504.5.13.1.1.4.1.9
Count of Unavailable Seconds since the unit was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataInits 1.3.6.1.4.1.5504.5.13.1.1.4.1.10
Count of the line initialization attempts since the unit was last reset. This count includes both successful and failed attempts.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinTimeElapsed 1.3.6.1.4.1.5504.5.13.1.1.4.1.11
Total elapsed seconds in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..86399  

zhoneVdslPerfDataCurr15MinLofs 1.3.6.1.4.1.5504.5.13.1.1.4.1.12
Count of seconds during this interval that there was Loss of Framing.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinLoss 1.3.6.1.4.1.5504.5.13.1.1.4.1.13
Count of seconds during this interval that there was Loss of Signal.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinLprs 1.3.6.1.4.1.5504.5.13.1.1.4.1.14
Count of seconds during this interval that there was Loss of Power.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinLols 1.3.6.1.4.1.5504.5.13.1.1.4.1.15
Count of seconds during this interval that there was Loss of Link.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.16
Count of Errored Seconds during this interval. An Errored Second is a one-second interval containing one or more CRC anomalies, or one or more LOS or LOF defects.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinSESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.17
Count of Severely Errored Seconds during this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinUASs 1.3.6.1.4.1.5504.5.13.1.1.4.1.18
Count of Unavailable Seconds during this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr15MinInits 1.3.6.1.4.1.5504.5.13.1.1.4.1.19
Count of the line initialization attempts during this interval. This count includes both successful and failed attempts.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfData1DayValidIntervals 1.3.6.1.4.1.5504.5.13.1.1.4.1.20
Valid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslPerfData1DayInvalidIntervals 1.3.6.1.4.1.5504.5.13.1.1.4.1.21
Invalid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslPerfDataCurr1DayTimeElapsed 1.3.6.1.4.1.5504.5.13.1.1.4.1.22
Number of seconds that have elapsed since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..86399  

zhoneVdslPerfDataCurr1DayLofs 1.3.6.1.4.1.5504.5.13.1.1.4.1.23
Count of Loss of Framing (LOF) Seconds since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayLoss 1.3.6.1.4.1.5504.5.13.1.1.4.1.24
Count of Loss of Signal (LOS) Seconds since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayLprs 1.3.6.1.4.1.5504.5.13.1.1.4.1.25
Count of Loss of Power (LPR) Seconds since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayLols 1.3.6.1.4.1.5504.5.13.1.1.4.1.26
Count of Loss of Link (LOL) Seconds since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.27
Count of Errored Seconds (ES) since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DaySESs 1.3.6.1.4.1.5504.5.13.1.1.4.1.28
Count of Severely Errored Seconds (SES) since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayUASs 1.3.6.1.4.1.5504.5.13.1.1.4.1.29
Count of Unavailable Seconds (UAS) since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerfDataCurr1DayInits 1.3.6.1.4.1.5504.5.13.1.1.4.1.30
Count of the line initialization attempts since the beginning of the current 1-day interval. This count includes both successful and failed attempts.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.31
Retransmitted Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCorrectedRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.32
Retransmitted corrected Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrUncorrectableRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.33
Retransmitted uncorrectable Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr15MinRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.34
Current 15 minutes Retransmitted Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr15MinCorrectedRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.35
Current 15 minutes Retransmitted Corrected Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr15MinUncorrectableRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.36
Current 15 minutes Retransmitted Uncorrectable Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr1DayRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.37
Current Day Retransmitted Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr1DayCorrectedRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.38
Current Day Retransmitted Corrected Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrCurr1DayUncorrectableRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.39
Current Day Retransmitted Uncorrectable Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrPrev1DayRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.40
Previous Day Retransmitted Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrPrev1DayCorrectedRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.41
Previous Day Retransmitted Corrected Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPhyrPrev1DayUncorrectableRetransmittedCodewords 1.3.6.1.4.1.5504.5.13.1.1.4.1.42
Previous Day Retransmitted Uncorrectable Codewords
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpLeftrSecs 1.3.6.1.4.1.5504.5.13.1.1.4.1.43
LEFTRS - This counter counts the number of seconds that experienced a Low Error Free Throughput Rate (LEFTR), i,e., seconds during which the Error Free Throughput dropped below the configured threshold.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpErrorFreeBits 1.3.6.1.4.1.5504.5.13.1.1.4.1.44
errorFreeBits - This counter counts the number of bits that crossed the alpha1/beta1 interface (bits available to carry user payload).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpMinEftr 1.3.6.1.4.1.5504.5.13.1.1.4.1.45
minEFTR - This performance monitoring parameter records the lowest value of Error Free Throughput during the current interval.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr15MinLeftrSecs 1.3.6.1.4.1.5504.5.13.1.1.4.1.46
LEFTRS - This counter counts the number of seconds that experienced a Low Error Free Throughput Rate (LEFTR), i,e., seconds during which the Error Free Throughput dropped below the configured threshold. This is the count for the current 15 minutes.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr15MinErrorFreeBits 1.3.6.1.4.1.5504.5.13.1.1.4.1.47
errorFreeBits - This counter counts the number of bits that crossed the alpha1/beta1 interface (bits available to carry user payload). This is the count for the current 15 minutes.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr15MinMinEftr 1.3.6.1.4.1.5504.5.13.1.1.4.1.48
minEFTR - This performance monitoring parameter records the lowest value of Error Free Throughput during the current interval. This is the count for the current 15 minutes.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr1DayLeftrSecs 1.3.6.1.4.1.5504.5.13.1.1.4.1.49
LEFTRS - This counter counts the number of seconds that experienced a Low Error Free Throughput Rate (LEFTR), i,e., seconds during which the Error Free Throughput dropped below the configured threshold. This is the count for the current day.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr1DayErrorFreeBits 1.3.6.1.4.1.5504.5.13.1.1.4.1.50
errorFreeBits - This counter counts the number of bits that crossed the alpha1/beta1 interface (bits available to carry user payload). This is the count for the current day.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpCurr1DayMinEftr 1.3.6.1.4.1.5504.5.13.1.1.4.1.51
minEFTR - This performance monitoring parameter records the lowest value of Error Free Throughput during the current interval. This is the count for the current day.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslGinpPrev1DayLeftrSecs 1.3.6.1.4.1.5504.5.13.1.1.4.1.52
LEFTRS - This counter counts the number of seconds that experienced a Low Error Free Throughput Rate (LEFTR), i,e., seconds during which the Error Free Throughput dropped below the configured threshold. This is the count for the previous day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslGinpPrev1DayErrorFreeBits 1.3.6.1.4.1.5504.5.13.1.1.4.1.53
errorFreeBits - This counter counts the number of bits that crossed the alpha1/beta1 interface (bits available to carry user payload). This is the count for the previous day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslGinpPrev1DayMinEftr 1.3.6.1.4.1.5504.5.13.1.1.4.1.54
minEFTR - This performance monitoring parameter records the lowest value of Error Free Throughput during the current interval. This is the count for the previous day.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslPerfIntervalTable 1.3.6.1.4.1.5504.5.13.1.1.5
This table provides one row for each Vtu performance data collection interval. VDSL physical interfaces are those ifEntries where ifType is equal to vdsl(97).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslPerfIntervalEntry

zhoneVdslPerfIntervalEntry 1.3.6.1.4.1.5504.5.13.1.1.5.1
An entry in the vdslPerfIntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslPerfIntervalEntry  

zhoneVdslPerfIntervalNumber 1.3.6.1.4.1.5504.5.13.1.1.5.1.1
Performance Data Interval number 1 is the most recent previous interval; interval 96 is 24 hours ago. Intervals 2 to 96 are optional.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..96  

zhoneVdslPerfIntervalLofs 1.3.6.1.4.1.5504.5.13.1.1.5.1.2
Count of seconds in the interval when there was Loss of Framing.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalLoss 1.3.6.1.4.1.5504.5.13.1.1.5.1.3
Count of seconds in the interval when there was Loss of Signal.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalLprs 1.3.6.1.4.1.5504.5.13.1.1.5.1.4
Count of seconds in the interval when there was Loss of Power.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalLols 1.3.6.1.4.1.5504.5.13.1.1.5.1.5
Count of seconds in the interval when there was Loss of Link.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalESs 1.3.6.1.4.1.5504.5.13.1.1.5.1.6
Count of Errored Seconds (ES) in the interval. An Errored Second is a one-second interval containing one or more CRC anomalies, one or more LOS or LOF defects.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalSESs 1.3.6.1.4.1.5504.5.13.1.1.5.1.7
Count of Severely Errored Seconds in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalUASs 1.3.6.1.4.1.5504.5.13.1.1.5.1.8
Count of Unavailable Seconds in the interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerfIntervalInits 1.3.6.1.4.1.5504.5.13.1.1.5.1.9
Count of the line initialization attempts during this interval. This count includes both successful and failed attempts.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslPerf1DayIntervalTable 1.3.6.1.4.1.5504.5.13.1.1.6
This table provides one row for each VDSL performance data collection interval. This table contains live data from equipment. As such, it is NOT persistent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslPerf1DayIntervalEntry

zhoneVdslPerf1DayIntervalEntry 1.3.6.1.4.1.5504.5.13.1.1.6.1
An entry in the vdslPerf1DayIntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslPerf1DayIntervalEntry  

zhoneVdslPerf1DayIntervalNumber 1.3.6.1.4.1.5504.5.13.1.1.6.1.1
History Data Interval number. Interval 1 is the most recent previous day; interval 30 is 30 days ago. Intervals 2 to 30 are optional.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..30  

zhoneVdslPerf1DayIntervalMoniSecs 1.3.6.1.4.1.5504.5.13.1.1.6.1.2
The amount of time in the 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the interval duration except in a situation where performance monitoring data could not be collected for any reason.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfTimeElapsed  

zhoneVdslPerf1DayIntervalLofs 1.3.6.1.4.1.5504.5.13.1.1.6.1.3
Count of Loss of Frame (LOF) Seconds during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalLoss 1.3.6.1.4.1.5504.5.13.1.1.6.1.4
Count of Loss of Signal (LOS) Seconds during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalLprs 1.3.6.1.4.1.5504.5.13.1.1.6.1.5
Count of Loss of Power (LPR) Seconds during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalLols 1.3.6.1.4.1.5504.5.13.1.1.6.1.6
Count of Loss of Link (LOL) Seconds during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalESs 1.3.6.1.4.1.5504.5.13.1.1.6.1.7
Count of Errored Seconds (ES) during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalSESs 1.3.6.1.4.1.5504.5.13.1.1.6.1.8
Count of Severely Errored Seconds (SES) during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalUASs 1.3.6.1.4.1.5504.5.13.1.1.6.1.9
Count of Unavailable Seconds (UAS) during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslPerf1DayIntervalInits 1.3.6.1.4.1.5504.5.13.1.1.6.1.10
Count of the line initialization attempts during the 1-day interval as measured by vdslPerf1DayIntervalMoniSecs. This count includes both successful and failed attempts.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

zhoneVdslChanPerfDataTable 1.3.6.1.4.1.5504.5.13.1.1.7
This table provides one row for each Vtu channel. VDSL channel interfaces are those ifEntries where ifType is equal to interleave(124) or fast(125).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslChanPerfDataEntry

zhoneVdslChanPerfDataEntry 1.3.6.1.4.1.5504.5.13.1.1.7.1
An entry in the vdslChanPerfDataTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslChanPerfDataEntry  

zhoneVdslChanValidIntervals 1.3.6.1.4.1.5504.5.13.1.1.7.1.1
Valid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslChanInvalidIntervals 1.3.6.1.4.1.5504.5.13.1.1.7.1.2
Invalid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslChanFixedOctets 1.3.6.1.4.1.5504.5.13.1.1.7.1.3
Count of corrected octets since the unit was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChanBadBlks 1.3.6.1.4.1.5504.5.13.1.1.7.1.4
Count of uncorrectable blocks since the unit was last reset.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChanCurr15MinTimeElapsed 1.3.6.1.4.1.5504.5.13.1.1.7.1.5
Total elapsed seconds in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..86399  

zhoneVdslChanCurr15MinFixedOctets 1.3.6.1.4.1.5504.5.13.1.1.7.1.6
Count of corrected octets in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChanCurr15MinBadBlks 1.3.6.1.4.1.5504.5.13.1.1.7.1.7
Count of uncorrectable blocks in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChan1DayValidIntervals 1.3.6.1.4.1.5504.5.13.1.1.7.1.8
Valid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslChan1DayInvalidIntervals 1.3.6.1.4.1.5504.5.13.1.1.7.1.9
Invalid Intervals per definition found in HC-PerfHist-TC-MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..96  

zhoneVdslChanCurr1DayTimeElapsed 1.3.6.1.4.1.5504.5.13.1.1.7.1.10
Number of seconds that have elapsed since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..86399  

zhoneVdslChanCurr1DayFixedOctets 1.3.6.1.4.1.5504.5.13.1.1.7.1.11
Count of corrected octets since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChanCurr1DayBadBlks 1.3.6.1.4.1.5504.5.13.1.1.7.1.12
Count of uncorrectable blocks since the beginning of the current 1-day interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslChanIntervalTable 1.3.6.1.4.1.5504.5.13.1.1.8
This table provides one row for each Vtu channel data collection interval. VDSL channel interfaces are those ifEntries where ifType is equal to interleave(124) or fast(125).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslChanIntervalEntry

zhoneVdslChanIntervalEntry 1.3.6.1.4.1.5504.5.13.1.1.8.1
An entry in the vdslChanIntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslChanIntervalEntry  

zhoneVdslChanIntervalNumber 1.3.6.1.4.1.5504.5.13.1.1.8.1.1
Performance Data Interval number 1 is the most recent previous interval; interval 96 is 24 hours ago. Intervals 2 to 96 are optional.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..96  

zhoneVdslChanIntervalFixedOctets 1.3.6.1.4.1.5504.5.13.1.1.8.1.2
Count of corrected octets in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslChanIntervalBadBlks 1.3.6.1.4.1.5504.5.13.1.1.8.1.3
Count of uncorrectable blocks in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfIntervalCount  

zhoneVdslChan1DayIntervalTable 1.3.6.1.4.1.5504.5.13.1.1.9
This table provides one row for each VDSL performance data collection interval. This table contains live data from equipment. As such, it is NOT persistent.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslChan1DayIntervalEntry

zhoneVdslChan1DayIntervalEntry 1.3.6.1.4.1.5504.5.13.1.1.9.1
An entry in the vdslChan1DayIntervalTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslChan1DayIntervalEntry  

zhoneVdslChan1DayIntervalNumber 1.3.6.1.4.1.5504.5.13.1.1.9.1.1
History Data Interval number. Interval 1 is the most recent previous day; interval 30 is 30 days ago. Intervals 2 to 30 are optional.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..30  

zhoneVdslChan1DayIntervalMoniSecs 1.3.6.1.4.1.5504.5.13.1.1.9.1.2
The amount of time in the 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the interval duration except in a situation where performance monitoring data could not be collected for any reason.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfTimeElapsed  

zhoneVdslChan1DayIntervalFixedOctets 1.3.6.1.4.1.5504.5.13.1.1.9.1.3
Count of corrected octets in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfCurrentCount  

zhoneVdslChan1DayIntervalBadBlks 1.3.6.1.4.1.5504.5.13.1.1.9.1.4
Count of uncorrectable blocks in this interval.
Status: current Access: read-only
OBJECT-TYPE    
  HCPerfCurrentCount  

zhoneVdslLineConfProfileTable 1.3.6.1.4.1.5504.5.13.1.1.11
This table contains information on the VDSL line configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line. Entries in this table MUST be maintained in a persistent manner.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslLineConfProfileEntry

zhoneVdslLineConfProfileEntry 1.3.6.1.4.1.5504.5.13.1.1.11.1
Each entry consists of a list of parameters that represents the configuration of a VDSL line. A default profile with an index of 'DEFVAL', will always exist and its parameters will be set to vendor specific values, unless otherwise specified in this document.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslLineConfProfileEntry  

zhoneVdslLineConfProfileName 1.3.6.1.4.1.5504.5.13.1.1.11.1.1
This object identifies a row in this table. A default profile with an index of 'DEFVAL', will always exist and its parameters will be set to vendor specific values, unless otherwise specified in this document.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

zhoneVdslLineConfDownRateMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.2
Specifies the rate selection behavior for the line in the downstream direction. manual(1) forces the rate to the configured rate adaptAtInit(2) adapts the line at initialization only dynamic(3) adapts the line at initialization and showtime
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER manual(1), adapt-at-init(2), dynamic(3)  

zhoneVdslLineConfUpRateMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.3
Specifies the rate selection behavior for the line in the upstream direction. manual(1) forces the rate to the configured rate adaptAtInit(2) adapts the line at initialization only dynamic(3) adapts the line at initialization and showtime
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER manual(1), adapt-at-init(2), dynamic(3)  

zhoneVdslLineConfDownMaxPwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.4
Specifies the maximum aggregate downstream power level in the range -5.0 to 20.0 dBm.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -50..200  

zhoneVdslLineConfUpMaxPwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.5
Specifies the maximum aggregate upstream power level in the range -13.0 to 20.0 dBm.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -130..200  

zhoneVdslLineConfDownMaxSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.6
Specifies the maximum downstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfDownMinSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.7
Specifies the minimum downstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfDownTargetSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.8
Specifies the target downstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB. This is the Noise Margin the transceivers must achieve with a BER of 10^-7 or better to successfully complete initialization.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfUpMaxSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.9
Specifies the maximum upstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfUpMinSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.10
Specifies the minimum upstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfUpTargetSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.11
Specifies the target upstream Signal/Noise Margin in units of 0.10 dB, for a range of 0 to 31.0 dB. This is the Noise Margin the transceivers must achieve with a BER of 10^-7 or better to successfully complete initialization.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..310  

zhoneVdslLineConfDownFastMaxDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.12
Specifies the maximum downstream fast channel data rate in steps of 1000 bits/second.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfDownFastMinDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.13
Specifies the minimum downstream fast channel data rate in steps of 1000 bits/second.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfDownSlowMaxDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.14
Specifies the maximum downstream slow channel data rate in steps of 1000 bits/second. The maximum aggregate downstream transmit speed of the line can be derived from the sum of maximum downstream fast and slow channel data rates.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfDownSlowMinDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.15
Specifies the minimum downstream slow channel data rate in steps of 1000 bits/second. The minimum aggregate downstream transmit speed of the line can be derived from the sum of minimum downstream fast and slow channel data rates.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfUpFastMaxDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.16
Specifies the maximum upstream fast channel data rate in steps of 1000 bits/second. The maximum aggregate upstream transmit speed of the line can be derived from the sum of maximum upstream fast and slow channel data rates.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfUpFastMinDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.17
Specifies the minimum upstream fast channel data rate in steps of 1000 bits/second. The minimum aggregate upstream transmit speed of the line can be derived from the sum of minimum upstream fast and slow channel data rates.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfUpSlowMaxDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.18
Specifies the maximum upstream slow channel data rate in steps of 1000 bits/second.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfUpSlowMinDataRate 1.3.6.1.4.1.5504.5.13.1.1.11.1.19
Specifies the minimum upstream slow channel data rate in steps of 1000 bits/second.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfDownRateRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.20
For dynamic rate adaptation at startup, the allocation of data rate in excess of the minimum data rate for each channel is controlled by the object. This object specifies the ratio of the allocation of the excess data rate between the fast and the slow channels. This allocation represents downstream Fast Channel Allocation / Slow Channel Allocation.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..100  

zhoneVdslLineConfUpRateRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.21
For dynamic rate adaptation at startup, the allocation of data rate in excess of the minimum data rate for each channel is controlled by the object. This object specifies the ratio of the allocation of the excess data rate between the fast and the slow channels. This allocation represents upstream Fast Channel Allocation/Slow Channel Allocation.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..100  

zhoneVdslLineConfDownMaxInterDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.22
Specifies the maximum interleave delay for the downstream slow channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

zhoneVdslLineConfUpMaxInterDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.23
Specifies the maximum interleave delay for the upstream slow channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

zhoneVdslLineConfDownPboControl 1.3.6.1.4.1.5504.5.13.1.1.11.1.24
Downstream power backoff (PBO) control for this line. For transceivers which do not support downstream PBO control, this object MUST be fixed at disabled(1). If auto(2) is selected, the transceiver will automatically adjust the power backoff. If manual(3) is selected, then the transceiver will use the value from zhoneVdslLineConfDownPboLevel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), auto(2), manual(3)  

zhoneVdslLineConfUpPboControl 1.3.6.1.4.1.5504.5.13.1.1.11.1.25
Upstream power backoff (PBO) control for this line. For transceivers which do not support upstream PBO control, this object MUST be fixed at disabled(1). If auto(2) is selected, the transceiver will automatically adjust the power backoff. If manual(3) is selected, then the transceiver will use the value from zhoneVdslLineConfUpPboLevel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), auto(2), manual(3)  

zhoneVdslLineConfDownPboLevel 1.3.6.1.4.1.5504.5.13.1.1.11.1.26
Specifies the downstream backoff level to be used when vdslLineConfDownPboControl = manual(3).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..160  

zhoneVdslLineConfUpPboLevel 1.3.6.1.4.1.5504.5.13.1.1.11.1.27
Specifies the upstream backoff level to be used when vdslLineConfUpPboControl = manual(3).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..160  

zhoneVdslLineConfDeploymentScenario 1.3.6.1.4.1.5504.5.13.1.1.11.1.28
The VDSL line deployment scenario. When using fttCab(1), the VTU-C is located in a street cabinet. When using fttEx(2), the VTU-C is located at the central office. Changes to this value will have no effect on the transceiver.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER fttCab(1), fttEx(2), other(3)  

zhoneVdslLineConfAdslPresence 1.3.6.1.4.1.5504.5.13.1.1.11.1.29
Indicates presence of ADSL service in the associated cable bundle/binder. none(1) indicates no ADSL service in the bundle adslOverPots(2) indicates ADSL service over POTS is present in the bundle adslOverISDN(3) indicates ADSL service over ISDN is present in the bundle
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), adslOverPots(2), adslOverISDN(3)  

zhoneVdslLineConfApplicableStandard 1.3.6.1.4.1.5504.5.13.1.1.11.1.30
The VDSL standard to be used for the line. ansi(1) indicates ANSI standard etsi(2) indicates ETSI standard itu(3) indicates ITU standard other(4) indicates a standard other than the above.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ansi(1), etsi(2), itu(3), other(4)  

zhoneVdslLineConfBandPlan 1.3.6.1.4.1.5504.5.13.1.1.11.1.31
The VDSL band plan to be used for the line. bandPlan997(1) is to be used for ITU-T G.993.1 Bandplan-B ETSI Bandplan ANSI Plan 997 bandPlan998(2) is to be used for ITU-T G.993.1 Bandplan-A ANSI Plan 998 bandPlanFx(3) is to be used for ITU-T G.993.1 Bandplan-C. other(4) is to be used for non-standard bandplans. If this object is set to bandPlanFx(3), then the object vdslLineConfBandPlanFx MUST also be set.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER bandPlan997(1), bandPlan998(2), bandPlanFx(3), other(4), bandPlan997-2(5), bandPlan997-3(6), bandPlan998-2(7), bandPlan998-3(8), bandPlan998-17-6(9), fx-2(10), fx-3(11), china-a-2(12), china-a-3(13), china-b-2(14), china-b-3(15)  

zhoneVdslLineConfBandPlanFx 1.3.6.1.4.1.5504.5.13.1.1.11.1.32
The frequency limit between bands D2 and U2 when zhoneVdslLineConfBandPlan is set to bandPlanFx(3).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 3750..12000  

zhoneVdslLineConfBandOptUsage 1.3.6.1.4.1.5504.5.13.1.1.11.1.33
Defines the VDSL link use of the optional frequency range [25kHz - 138kHz] (Opt). unused(1) indicates Opt is unused upstream(2) indicates Opt usage is for upstream downstream(3) indicates Opt usage is for downstream. upstreamForced(4) indicates forced upstream
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unused(1), upstream(2), downstream(3), upstream-forced(4)  

zhoneVdslLineConfUpPsdTemplate 1.3.6.1.4.1.5504.5.13.1.1.11.1.34
This object has been modified by Zhone. The upstream PSD template to be used for the line. Here, templateMask1(1) refers to a notched mask that limits the transmitted PSD within the internationally standardized HAM (Handheld Amateur Radio) radio bands, while templateMask2(2) refers to an unnotched mask. The masks themselves depend upon the applicable standard being used (vdslLineConfApplicableStandard).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ansi-fftex-m1(3), ansi-fftex-m2(4), ansi-fftcab-m1(5), fftcab-m2(6), etsi-m1(7), etsi-m2(8), psd-custom(9)  

zhoneVdslLineConfDownPsdTemplate 1.3.6.1.4.1.5504.5.13.1.1.11.1.35
This object has been modified by Zhone. The downstream PSD template to be used for the line. Here, templateMask1(1) refers to a notched mask that limits the transmitted PSD within the internationally standardized HAM (Handheld Amateur Radio) radio bands, while templateMask2(2) refers to an unnotched mask. The masks themselves depend upon the applicable standard being used (vdslLineConfApplicableStandard).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ansi-fftex-m1(3), ansi-fftex-m2(4), ansi-fftcab-m1(5), fftcab-m2(6), fftcab-m1-adsl(7), fftcab-m1-adslplus(8), fftcab-m2-adsl(9), fftcab-m2-adslplus(10), etsi-pexp1-m1(11), etsi-pexp1-m2(12), etsi-pexp2-m1(13), etsi-pexp2-m2(14), psd-custom(15), etsi-pexm2-sample1(16), etsi-pexm2-sample2(17), etsi-pexm2-sample3(18), etsi-pexm2-sample4(19), etsi-pcab-m1(20), etsi-pcab-m2(21)  

zhoneVdslLineConfHamBandMask 1.3.6.1.4.1.5504.5.13.1.1.11.1.36
The transmit power spectral density mask code, used to avoid interference with HAM (Handheld Amateur Radio) radio bands by introducing power control (notching) in one or more of these bands. Amateur radio band notching is defined in the VDSL spectrum as follows: Band Start Frequency Stop Frequency ---- ------------------ -------------------------------- 30m 1810 kHz 2000 kHz 40m 3500 kHz 3800 kHz (ETSI); 4000 kHz (ANSI) 80m 7000 kHz 7100 kHz (ETSI); 7300 kHz (ANSI) 160m 10100 kHz 10150 kHz Notching for each standard band can be enabled or disabled via the bit mask. Two custom notches may be specified. If either of these are enabled via the bit mask, then the following objects MUST be specified: If customNotch1 is enabled, then both zhoneVdslLineConfCustomNotch1Start zhoneVdslLineConfCustomNotch1Stop MUST be specified. If customNotch2 is enabled, then both zhoneVdslLineConfCustomNotch2Start zhoneVdslLineConfCustomNotch2Stop MUST be specified.
Status: current Access: read-create
OBJECT-TYPE    
  BITS customNotch1(0), customNotch2(1), amateurBand30m(2), amateurBand40m(3), amateurBand80m(4), amateurBand160m(5)  

zhoneVdslLineConfCustomNotch1Start 1.3.6.1.4.1.5504.5.13.1.1.11.1.37
Specifies the start frequency of custom HAM (Handheld Amateur Radio) notch 1. zhoneVdslLineConfCustomNotch1Start MUST be less than or equal to vdslLineConfCustomNotch1Stop.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneVdslLineConfCustomNotch1Stop 1.3.6.1.4.1.5504.5.13.1.1.11.1.38
Specifies the stop frequency of custom HAM (Handheld Amateur Radio) notch 1. zhoneVdslLineConfCustomNotch1Stop MUST be greater than or equal to vdslLineConfCustomNotch1Start.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneVdslLineConfCustomNotch2Start 1.3.6.1.4.1.5504.5.13.1.1.11.1.39
Specifies the start frequency of custom HAM (Handheld Amateur Radio) notch 2. zhoneVdslLineConfCustomNotch2Start MUST be less than or equal to vdslLineConfCustomNotch2Stop.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneVdslLineConfCustomNotch2Stop 1.3.6.1.4.1.5504.5.13.1.1.11.1.40
Specifies the stop frequency of custom HAM (Handheld Amateur Radio) notch 2. zhoneVdslLineConfCustomNotch2Stop MUST be greater than or equal to vdslLineConfCustomNotch2Start.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

zhoneVdslLineConfDownTargetSlowBurst 1.3.6.1.4.1.5504.5.13.1.1.11.1.41
Specifies the target level of impulse noise (burst) protection for an interleaved (slow) channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..1275  

zhoneVdslLineConfUpTargetSlowBurst 1.3.6.1.4.1.5504.5.13.1.1.11.1.42
Specifies the target level of impulse noise (burst) protection for an interleaved (slow) channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..1275  

zhoneVdslLineConfDownMaxFastFec 1.3.6.1.4.1.5504.5.13.1.1.11.1.43
This parameter provisions the maximum level of Forward Error Correction (FEC) redundancy related overhead to be maintained for a fast channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..50  

zhoneVdslLineConfUpMaxFastFec 1.3.6.1.4.1.5504.5.13.1.1.11.1.44
This parameter provisions the maximum level of Forward Error Correction (FEC) redundancy related overhead to be maintained for a fast channel.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..50  

zhoneVdslLineConfLineType 1.3.6.1.4.1.5504.5.13.1.1.11.1.45
This parameter provisions the VDSL physical entity at start-up by defining whether and how the line will be channelized, i.e., which channel type(s) are supported. If the line is to be channelized, the value will be other than noChannel(1). This configuration can be activated only during start-up. Afterwards, the value of zhoneVdslLineType coincides with the value of zhoneVdslLineConfLineType. Depending on this value, the corresponding entries in the ifTable for the interleaved and the fast channels are enabled or disabled according to the value of their ifOperStatus. Defined values are: noChannel(1) -- no channels exist fastOnly(2) -- only fast channel exists interleavedOnly(3) -- only interleaved channel exists fastOrInterleaved(4) -- either fast or interleaved channel -- exists, but only one at a time fastAndInterleaved(5) -- both fast and interleaved channels -- exist Note that 'slow' and 'interleaved' refer to the same channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noChannel(1), fastOnly(2), interleavedOnly(3), fastOrInterleaved(4), fastAndInterleaved(5)  

zhoneVdslLineConfProfRowStatus 1.3.6.1.4.1.5504.5.13.1.1.11.1.47
This object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to 'active'. When 'active' is set, the system will validate the profile. Before a profile can be deleted or taken out of service (by setting this object to 'destroy' or 'outOfService'), it must be first unreferenced from all associated lines. An 'active' profile may be modified at any time. Note that some changes may require that any referenced lines be restarted (e.g., zhoneVdslLineConfLineType).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zhoneVdslLineConfTransmissionMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.48
The transmission standard to be used for the line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER autoNegotiateMode(1), vdslMode(2), vdsl2Mode(3), adsl2PlusMode(4), adsl2Mode(5), gdmtMode(6)  

zhoneVdslLineConfVdsl2Profile 1.3.6.1.4.1.5504.5.13.1.1.11.1.49
The VDSL2 standard to be used for the line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER g993-2-8a(1), g993-2-8b(2), g993-2-8c(3), g993-2-8d(4), g993-2-12a(5), g993-2-12b(6), g993-2-17a(7), g993-2-30a(8)  

zhoneVdslLineConfVdslMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.50
Controls which VDSL modes are available on the line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER standard(1), long-reach-8k(2), r8k(3), std-8k(4), lr-8k(5), std-lr(6), std-lr-8k(7)  

zhoneVdslLineConfPboElectricalOverride 1.3.6.1.4.1.5504.5.13.1.1.11.1.51
Override electrical length estimated by VUTU_C. The special value 256 means do not perform override.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..256  

zhoneVdslLineConfAutoModeCrtrn 1.3.6.1.4.1.5504.5.13.1.1.11.1.52
Determines the policy to select optimal mode of oepration.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER crtrn-chip-prop(1), optimize-us(2), optimize-ds(3)  

zhoneVdslLineConfNetworkTimingRef 1.3.6.1.4.1.5504.5.13.1.1.11.1.53
Enable/disable reference clock source.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfAdslBandMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.54
Specifies whether the XDSL can use the ADSL spectrum or not.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER allowed(1), not-allowed(2)  

zhoneVdslLineConfAdslBandModeEndFreq 1.3.6.1.4.1.5504.5.13.1.1.11.1.55
Specifies the ADSL band end frequency when the ADSL band usage is not allowed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 276..2208  

zhoneVdslLineConfSeltEchoMeasurementTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.56
Contains the SELT echo measurement time
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 5..240  

zhoneVdslLineConfSeltNoiseMeasurementTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.57
Contains the SELT noise measurement time.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 5..240  

zhoneVdslLineConfSeltAgc 1.3.6.1.4.1.5504.5.13.1.1.11.1.58
Contains the SELT AGC gain value.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -100..100  

zhoneVdslLineConfDownTrellis 1.3.6.1.4.1.5504.5.13.1.1.11.1.59
Enables/disables downstream Trellis coding.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpTrellis 1.3.6.1.4.1.5504.5.13.1.1.11.1.60
Enables/disables upstream Trellis coding.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfDownMaxAggregateTxPwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.61
Maximum total power that is allowed to be transmitted in the downstream direction.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unlimited(4)  

zhoneVdslLineConfUpMaxAggregateTxPwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.62
Maximum total power that is allowed to be transmitted in the upstream direction.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER unlimited(4)  

zhoneVdslLineConfDownMaxPsd 1.3.6.1.4.1.5504.5.13.1.1.11.1.63
The maximum power spectral density level allowed on the line at the transmitter output downstream for initialization and showtime signals.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -955..0  

zhoneVdslLineConfUpMaxPsd 1.3.6.1.4.1.5504.5.13.1.1.11.1.64
The maximum power spectral density level allowed on the line at the transmitter output upstream for initialization and showtime signals.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -955..0  

zhoneVdslLineConfDownPsdShape 1.3.6.1.4.1.5504.5.13.1.1.11.1.65
Maximum transmit PSD allowed in the downstream channel on a VDSL2 line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER custom-psd(1), region-a-psd(2), region-c-psd(3), region-b-m1-a-psd(4), region-b-m1-b-psd(5), region-b-m1-us0-psd(6), region-b-m2-a-psd(7), region-b-m2-m-psd(8), region-b-m2-b-psd(9), region-b-m2-us0-psd(10)  

zhoneVdslLineConfUpPsdShape 1.3.6.1.4.1.5504.5.13.1.1.11.1.66
Maximum transmit PSD allowed in the upstream channel on a VDSL2 line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER custom-psd(1), region-a-psd(2), region-c-psd(3), region-b-m1-a-psd(4), region-b-m1-b-psd(5), region-b-m1-us0-psd(6), region-b-m2-a-psd(7), region-b-m2-m-psd(8), region-b-m2-b-psd(9), region-b-m2-us0-psd(10)  

zhoneVdslLineConfDownVirtualNoiseSnrMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.67
Downstream virtual noise SNR mode on a VDSL2 line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2), mode3(3)  

zhoneVdslLineConfUpVirtualNoiseSnrMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.68
Upstream virtual noise SNR mode on a VDSL2 line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER mode1(1), mode2(2), mode3(3)  

zhoneVdslLineConfDownErasureDetectionFast 1.3.6.1.4.1.5504.5.13.1.1.11.1.69
Indicates whether the erasure detection mechanism should be enabled or disabled in the downstream fast channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpErasureDetectionFast 1.3.6.1.4.1.5504.5.13.1.1.11.1.70
Indicates whether the erasure detection mechanism should be enabled or disabled in the downstream fast channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfDownErasureDetectionInterleave 1.3.6.1.4.1.5504.5.13.1.1.11.1.71
Indicates whether the erasure detection mechanism should be enabled or disabled in the downstream slow channel (interleave).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpErasureDetectionInterleave 1.3.6.1.4.1.5504.5.13.1.1.11.1.72
Indicates whether the erasure detection mechanism should be enabled or disabled in the uptream slow channel (interleave).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfDownGhsA43TonePwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.73
Determines the mode of the downstream tones power used during handshake, during A43 mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER default(1), auto(2), manual(3)  

zhoneVdslLineConfDownGhsB43TonePwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.74
Determines the mode of the downstream tones power used during handshake, during B43 mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER default(1), auto(2), manual(3)  

zhoneVdslLineConfDownGhsA43cTonePwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.75
Determines the mode of the downstream tones power used during handshake, during A43c mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER default(1), auto(2), manual(3)  

zhoneVdslLineConfDownGhsV43TonePwr 1.3.6.1.4.1.5504.5.13.1.1.11.1.76
Determines the mode of the downstream tone power used during handshake, during V43 mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER default(1), auto(2), manual(3)  

zhoneVdslLineConfDownGhsA43TonePwrMaxLvl 1.3.6.1.4.1.5504.5.13.1.1.11.1.77
Determines the maximum power of downstream tones used, in manual mode, during handshake in A43 mode. A value of -99 indicates no power used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -99..-40  

zhoneVdslLineConfDownGhsB43TonePwrMaxLvl 1.3.6.1.4.1.5504.5.13.1.1.11.1.78
Determines the maximum power of downstream tones used, in manual mode, during handshake in B43 mode. A value of -99 indicates no power used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -99..-40  

zhoneVdslLineConfDownGhsA43cTonePwrMaxLvl 1.3.6.1.4.1.5504.5.13.1.1.11.1.79
Determines the maximum power of downstream tones used, in manual mode, during handshake in A43c mode. A value of -99 indicates no power used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -99..-40  

zhoneVdslLineConfDownGhsV43TonePwrMaxLvl 1.3.6.1.4.1.5504.5.13.1.1.11.1.80
Determines the maximum power of downstream tones used, in manual mode, during handshake in V43 mode. A value of -99 indicates no power used.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -99..-40  

zhoneVdslLineConfDownRsCoding 1.3.6.1.4.1.5504.5.13.1.1.11.1.81
Parameter to enable/disable RS Coding in downstream channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpRsCoding 1.3.6.1.4.1.5504.5.13.1.1.11.1.82
Parameter to enable/disable RS Coding in upsream channel.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpPboPsdTemplate 1.3.6.1.4.1.5504.5.13.1.1.11.1.83
Specifies the maximum received PSD allowed in the upstream channel on the VDSLx line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ansi-a(1), ansi-f(2), etsi-a(3), etsi-b(4), etsi-c(5), etsi-d(6), etsi-e(7), etsi-f(8), custom(9), ab-param(10)  

zhoneVdslLineConfUpPboPsdParamA1 1.3.6.1.4.1.5504.5.13.1.1.11.1.84
Upstream power backoff PSD parameter A1. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 4000..8589  

zhoneVdslLineConfUpPboPsdParamA2 1.3.6.1.4.1.5504.5.13.1.1.11.1.85
Upstream power backoff PSD parameter A2. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 4000..8589  

zhoneVdslLineConfUpPboPsdParamB1 1.3.6.1.4.1.5504.5.13.1.1.11.1.86
Upstream power backoff PSD parameter B1. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..8589  

zhoneVdslLineConfUpPboPsdParamB2 1.3.6.1.4.1.5504.5.13.1.1.11.1.87
Upstream power backoff PSD parameter B2. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..8589  

zhoneVdslLineConfDownDownshiftSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.88
Configured Signal/Noise Margin for rate downshift. If the noise margin falls below this level, the modem should attempt to decrease its transmit rate.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..310  

zhoneVdslLineConfDownUpshiftSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.89
Configured Signal/Noise Margin for rate upshift. If the noise margin rises above this level, the modem should attempt to increase its transmit rate.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..310  

zhoneVdslLineConfDownMinDownshiftTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.90
Minimum time that the current margin is below DownshiftSnrMgn before a downshift occurs.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16383  

zhoneVdslLineConfDownMinUpshiftTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.91
Minimum time that the current margin is above UpshiftSnrMgn before an upshift occurs.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16383  

zhoneVdslLineConfUpDownshiftSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.92
Configured Signal/Noise Margin for rate downshift. If the noise margin falls below this level, the modem should attempt to decrease its transmit rate.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..310  

zhoneVdslLineConfUpUpshiftSnrMgn 1.3.6.1.4.1.5504.5.13.1.1.11.1.93
Configured Signal/Noise Margin for rate upshift. If the noise margin rises above this level, the modem should attempt to increase its transmit rate.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..310  

zhoneVdslLineConfUpMinDownshiftTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.94
Minimum time that the current margin is below DownshiftSnrMgn before a downshift occurs.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16383  

zhoneVdslLineConfUpMinUpshiftTime 1.3.6.1.4.1.5504.5.13.1.1.11.1.95
Minimum time that the current margin is above UpshiftSnrMgn before an upshift occurs.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..16383  

zhoneVdslLineConfDownMinTxThresholdAlarm 1.3.6.1.4.1.5504.5.13.1.1.11.1.96
Minimum CO Tx Sync rate threshold alarm. If set to 0, this field is disregarded. Otherwise, if Tx Sync rate falls below this value, a trap and alarm will be issued
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfUpMinTxThresholdAlarm 1.3.6.1.4.1.5504.5.13.1.1.11.1.97
Minimum CPE Tx Sync rate threshold alarm. If set to 0, this field is disregarded. Otherwise, if Tx Sync rate falls below this value, a trap and alarm will be issued
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslLineConfPotsBypassRelayMaxDuration 1.3.6.1.4.1.5504.5.13.1.1.11.1.98
The maximum duration in seconds that an Adsl Pots Low Pass Filter Bypass Relay will remain active (meaning closed/energized). As a fail-safe mechanism, the relay will automatically return a line back to normal operational mode when this timer has expired. This object is only valid for Adsl Pots Splitter cards containing the Pots LPF Bypass Relays.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..300  

zhoneVdslLineConfDMTConfMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.99
Discrete Multi-Tone parameter that selects whether there is overlap (echoCancel) or no overlap (freqDivMux) of bins.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER echocancel(1), freqdivmux(2)  

zhoneVdslLineConfDownBitSwap 1.3.6.1.4.1.5504.5.13.1.1.11.1.100
Enable or disable downstream bit swap.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

zhoneVdslLineConfUpBitSwap 1.3.6.1.4.1.5504.5.13.1.1.11.1.101
Enable or disable upstream bit swap.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

zhoneVdslLineConfAdslAnnexMModeEnabled 1.3.6.1.4.1.5504.5.13.1.1.11.1.102
This object indicates whether Annex-M mode is enabled on the Adsl modem. If this object is set to 'true' then Annex-M mode is enabled. If it is set to 'false then Annex-M mode is disabled.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneVdslLineConfAdslAnnexMPsdMask 1.3.6.1.4.1.5504.5.13.1.1.11.1.103
This object specifies the maximum transmit PSD allowed in the downstream channel on an BIS Annex-M line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER eu64(1), eu60(2), eu56(3), eu52(4), eu48(5), eu44(6), eu40(7), eu36(8), eu32(9), all(10)  

zhoneVdslLineConfUs0BoundaryTone 1.3.6.1.4.1.5504.5.13.1.1.11.1.104
This object configures the upper boundary of US0. US0 is used in long reach mode when there is no more capacity in US1. The switchover is typically around 3500 feet.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER d32(1), d36(2), d40(3), d44(4), d48(5), d52(6), d56(7), d64(8)  

zhoneVdslLineConfDownInp 1.3.6.1.4.1.5504.5.13.1.1.11.1.105
The minimum impulse noise protection for the downstream bearer channel expressed in symbols. One symbol equals 250 uS.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noProtection(1), halfSymbol(2), singleSymbol(3), twoSymbols(4), threeSymbols(5), fourSymbols(6), fiveSymbols(7), sixSymbols(8), sevenSymbols(9), eightSymbols(10), nineSymbols(11), tenSymbols(12), elevenSymbols(13), twelveSymbols(14), thirteenSymbols(15), fourteenSymbols(16), fifteenSymbols(17), sixteenSymbols(18)  

zhoneVdslLineConfUpInp 1.3.6.1.4.1.5504.5.13.1.1.11.1.106
The minimum impulse noise protection for the upstream bearer channel expressed in symbols. One symbol equals 250 uS.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noProtection(1), halfSymbol(2), singleSymbol(3), twoSymbols(4), fourSymbols(5), eightSymbols(6), sixteenSymbols(7), threeSymbols(8), fiveSymbols(9), sixSymbols(10), sevenSymbols(11), nineSymbols(12), tenSymbols(13), elevenSymbols(14), twelveSymbols(15), thirteenSymbols(16), fourteenSymbols(17), fifteenSymbols(18)  

zhoneVdslLineConfDownMaxInterleavingDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.107
The maximum inteleaving delay in the downstream direction. A value of zero indicates no delay introduced.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..63  

zhoneVdslLineConfUpMaxInterleavingDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.108
The maximum inteleaving delay in the upstream direction. A value of zero indicates no delay introduced.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..63  

zhoneVdslLineConfDownPsdMaskEnable 1.3.6.1.4.1.5504.5.13.1.1.11.1.109
This object selects the Psd Mask in the downstream direction. 'standard' : use the PSD Mask specified in the object zhoneVdslLineConfDownPsdSelect 'mod' : use the pre-defined Mask-On-Demand PSD Mask 'modFallback': use the pre-defined Mask-On-Demand PSD Mask with fallback
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER standard(2), mod(3), modFallback(4)  

zhoneVdslLineConfUpPsdMaskEnable 1.3.6.1.4.1.5504.5.13.1.1.11.1.110
This object selects the Psd Mask in the upstream direction. 'standard' : use the PSD Mask specified in the object zhoneVdslLineConfDownPsdSelect 'mod' : use the pre-defined Mask-On-Demand PSD Mask 'modFallback': use the pre-defined Mask-On-Demand PSD Mask with fallback
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER standard(2), mod(3), modFallback(4)  

zhoneVdslLineConfDownPsdMaskSelect 1.3.6.1.4.1.5504.5.13.1.1.11.1.111
This object selects one of the standards based PSD mask for the downstream direction. The object zhoneVdslLineConfDownPsdMaskEnable must be set to 'standard' for this object to be active.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER custom(1), customMOD(2), dmtPSDCOMSK2(3), dmtPSDFLATMSK(4), dmtPSDCABMSK2(5), dmtPSDCOMSK2RFI(6), dmtPSDFLATMSKRFI(7), dmtPSDCABMSK2RFI(8), dmtPSDADSL2NONOVLPM1(9), dmtPSDADSL2NONOVLPM2(10), dmtPSDADSL2NONOVLPFLAT(11), g993RegionC(12), g993RegionA(13), g993RegionA-E17a-D-32(14), g993RegionA-E17a-D-48(15), g993RegionA-E17a-D-64(16), g993RegionA-E17a-D-128(17), g998RegionB-M1x-A(18), g998RegionB-M1x-B(19), g998RegionB-M1x-NUS0(20), g998RegionB-M2x-A(21), g998RegionB-M2x-M(22), g998RegionB-M2x-B(23), g998RegionB-M2x-NUS0(24), g998RegionB-E17-M2x-NUS0(25), g998RegionB-E17-M2x-NUS0-M(26), g998RegionB-ADE17-M2x-NUS0-M(27), g998RegionB-ADE17-M2x-A(28), g998RegionB-ADE17-M2x-B(29), g998RegionB-E30-M2x-NUS0(30), g998RegionB-E30-M2x-NUS0-M(31), g998RegionB-ADE30-M2x-NUS0-M(32), g998RegionB-ADE30-M2x-NUS0-A(33), g998RegionB-NONSTD-E17-M2x(34), g998RegionB-NONSTD-E17-M2x-M(35), g997RegionB-M1c-A-7(36), g997RegionB-M1x-M-8(37), g997RegionB-M1x-M(38), g997RegionB-M2x-M-8(39), g997RegionB-M2x-A(40), g997RegionB-M2x-M(41), g997RegionB-HPE17-M1-NUS0(42), g997RegionB-HPE30-M1-NUS0(43), g997RegionB-E17-M2x-A(44), g997RegionB-E30-M2x-NUS0(45)  

zhoneVdslLineConfUpPsdMaskSelect 1.3.6.1.4.1.5504.5.13.1.1.11.1.112
This object selects one of the standards based PSD mask for the upstream direction. The object zhoneVdslLineConfUpPsdMaskEnable must be set to 'standard' for this object to be active.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER custom(1), g993J-ADLU-32(2), g993J-ADLU-36(3), g993J-ADLU-40(4), g993J-ADLU-44(5), g993J-ADLU-48(6), g993J-ADLU-52(7), g993J-ADLU-60(8), g993J-ADLU-64(9), g993JM-EU-32(10), g993JM-EU-36(11), g993JM-EU-40(12), g993JM-EU-44(13), g993JM-EU-48(14), g993JM-EU-52(15), g993JM-EU-60(16), g993JM-EU-64(17), dmtExtended(18), dmtJJ100(19), dmtStandard(20), g993RegionA-EU-32(21), g993RegionA-EU-36(22), g993RegionA-EU-40(23), g993RegionA-EU-44(24), g993RegionA-EU-48(25), g993RegionA-EU-52(26), g993RegionA-EU-56(27), g993RegionA-EU-60(28), g993RegionA-EU-64(29), g998RegionB-M1x-A(30), g998RegionB-M1x-B(31), g998RegionB-M1x-NUS0(32), g998RegionB-M2x-A(33), g998RegionB-M2x-M(34), g998RegionB-M2x-B(35), g998RegionB-M2x-NUS0(36), g998RegionB-E17-M2x-NUS0(37), g998RegionB-E17-M2x-NUS0-M(38), g998RegionB-ADE17-M2x-NUS0-M(39), g998RegionB-ADE17-M2x-A(40), g998RegionB-ADE17-M2x-B(41), g998RegionB-E30-M2x-NUS0(42), g998RegionB-E30-M2x-NUS0-M(43), g998RegionB-ADE30-M2x-NUS0-M(44), g998RegionB-ADE30-M2x-NUS0-A(45), g998RegionB-NONSTD-E17-M2x(46), g998RegionB-NONSTD-E17-M2x-M(47), g997RegionB-M1c-A-7(48), g997RegionB-M1x-M-8(49), g997RegionB-M1x-M(50), g997RegionB-M2x-M-8(51), g997RegionB-M2x-A(52), g997RegionB-M2x-M(53), g997RegionB-HPE17-M1-NUS0(54), g997RegionB-HPE30-M1-NUS0(55), g997RegionB-E17-M2x-A(56), g997RegionB-E30-M2x-NUS0(57)  

zhoneVdslLineEnableTrellisCoding 1.3.6.1.4.1.5504.5.13.1.1.11.1.113
Enables/disables Trellis coding.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneVdslLineEnableRsCoding 1.3.6.1.4.1.5504.5.13.1.1.11.1.114
Enables/disables Rs coding.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneVdslLineConfPsdShape 1.3.6.1.4.1.5504.5.13.1.1.11.1.115
Maximum transmit PSD allowed on a VDSL2 line.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER region-a-nus0(1), region-a-eu-32(2), region-a-eu-36(3), region-a-eu-40(4), region-a-eu-44(5), region-a-eu-48(6), region-a-eu-52(7), region-a-eu-56(8), region-a-eu-60(9), region-a-eu-64(10), region-a-eu-128(11), region-a-adlu-32(12), region-a-adlu-36(13), region-a-adlu-40(14), region-a-adlu-44(15), region-a-adlu-48(16), region-a-adlu-52(17), region-a-adlu-56(18), region-a-adlu-60(19), region-a-adlu-64(20), region-a-adlu-128(21), region-b-998-m1x-a(22), region-b-998-m1x-b(23), region-b-998-m1x-nus0(24), region-b-998-m2x-a(25), region-b-998-m2x-m(26), region-b-998-m2x-b(27), region-b-998-m2x-nus0(28), region-b-998-e17-m2x-nus0(29), region-b-998-e17-m2x-nus0-m(30), region-b-998-ade17-m2x-nus0-m(31), region-b-998-ade17-m2x-a(32), region-b-998-ade17-m2x-b(33), region-b-998-e30-m2x-nus0(34), region-b-998-e30-m2x-nus0-m(35), region-b-998-ade30-m2x-nus0-m(36), region-b-998-ade30-m2x-nus0-a(37), region-b-997-m1c-a-7(38), region-b-997-m1x-m-8(39), region-b-997-m1x-m(40), region-b-997-m2x-m-8(41), region-b-997-m2x-a(42), region-b-997-m2x-m(43), region-b-997-hpe17-m1-nus0(44), region-b-997-hpe30-m1-nus0(45), region-b-997-e17-m2x-a(46), region-b-997-e30-m2x-nus0(47), region-b-997-bt-anfp(48), region-c-138-b(49), region-c-276-b(50), region-c-138-co(51), region-c-276-co(52), region-c-tcmisdn(53), region-c-1104-co-17a(54), region-c-1104-co-30a(55)  

zhoneVdslLineConfDownPhyRSupport 1.3.6.1.4.1.5504.5.13.1.1.11.1.116
Enable or disable downstream PHYR. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpPhyRSupport 1.3.6.1.4.1.5504.5.13.1.1.11.1.117
Enable or disable upstream PHYR. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfDownPhyRmaxINP 1.3.6.1.4.1.5504.5.13.1.1.11.1.118
PHYR maximum downstream impulse noise protection. A value of 0 specifies no protection. The values 5 through 160 specify the number of symbols in 1/10 increments. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0 | 5..160  

zhoneVdslLineConfUpPhyRmaxINP 1.3.6.1.4.1.5504.5.13.1.1.11.1.119
PHYR maximum upstream impulse noise protection. A value of 0 specifies no protection. The values 5 through 160 specify the number of symbols in 1/10 increments. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0 | 5..160  

zhoneVdslLineConfDownPhyRminRSoverhead 1.3.6.1.4.1.5504.5.13.1.1.11.1.120
PHYR minimum downstream RS overhead. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

zhoneVdslLineConfUpPhyRminRSoverhead 1.3.6.1.4.1.5504.5.13.1.1.11.1.121
PHYR minimum upstream RS overhead. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

zhoneVdslLineConfDownPhyRRtxRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.122
PHYR minimum downstream fraction of the line rate allocated for retransmission. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

zhoneVdslLineConfUpPhyRRtxRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.123
PHYR minimum upstream fraction of the line rate allocated for retransmission. Only supported by Broadcom PHYR ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

zhoneVdslLineConfUpPboPsdParamA3 1.3.6.1.4.1.5504.5.13.1.1.11.1.124
Upstream power backoff PSD parameter A3. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 4000..8096  

zhoneVdslLineConfUpPboPsdParamA4 1.3.6.1.4.1.5504.5.13.1.1.11.1.125
Upstream power backoff PSD parameter A4. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 4000..8096  

zhoneVdslLineConfUpPboPsdParamB3 1.3.6.1.4.1.5504.5.13.1.1.11.1.126
Upstream power backoff PSD parameter B3. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..4096  

zhoneVdslLineConfUpPboPsdParamB4 1.3.6.1.4.1.5504.5.13.1.1.11.1.127
Upstream power backoff PSD parameter B4. This parameter is only used if the mask selection is set to PSDMaskABParameters
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..4096  

zhoneVdslLineConfFallbackDefaultVpi 1.3.6.1.4.1.5504.5.13.1.1.11.1.128
ATM VPI to be used by the line when it trains in ADSL/ATM mode and bridges are configured for single-vc mode
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

zhoneVdslLineConfFallbackDefaultVci 1.3.6.1.4.1.5504.5.13.1.1.11.1.129
ATM VCI to be used by the line when it trains in ADSL/ATM mode and bridges are configured for single-vc mode
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..65535  

zhoneVdslLineConfDownGinpSupport 1.3.6.1.4.1.5504.5.13.1.1.11.1.130
Enable or disable downstream G.INP / ITU-G.998.4. Only supported by Broadcom ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfUpGinpSupport 1.3.6.1.4.1.5504.5.13.1.1.11.1.131
Enable or disable upstream G.INP / ITU-G.998.4. Only supported by Broadcom ports.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zhoneVdslLineConfDownGinpEtrMax 1.3.6.1.4.1.5504.5.13.1.1.11.1.132
gInpEtrMax - Maximum allowed value for downstream expected throughput (ETR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the maximum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..200000  

zhoneVdslLineConfUpGinpEtrMax 1.3.6.1.4.1.5504.5.13.1.1.11.1.133
gInpEtrMax - Maximum allowed value for upstream expected throughput (ETR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the maximum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..2000000  

zhoneVdslLineConfDownGinpEtrMin 1.3.6.1.4.1.5504.5.13.1.1.11.1.134
gInpEtrMin - Minimum allowed value for downstream expected throughput (ETR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the minimum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..200000  

zhoneVdslLineConfUpGinpEtrMin 1.3.6.1.4.1.5504.5.13.1.1.11.1.135
gInpEtrMin - Minimum allowed value for upstream expected throughput (ETR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the minimum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..200000  

zhoneVdslLineConfDownGinpNdrMax 1.3.6.1.4.1.5504.5.13.1.1.11.1.136
gInpNdrMax - Maximum allowed value for downstream net data rate (NDR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the maximum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..200000  

zhoneVdslLineConfUpGinpNdrMax 1.3.6.1.4.1.5504.5.13.1.1.11.1.137
gInpNdrMax - Maximum allowed value for upstream net data rate (NDR) in kbit/s. The valid values are all multiples of 8 from 0 to the maximum of the valid values of the maximum net data rate specified in the associated Recommendation. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 64..200000  

zhoneVdslLineConfDownGinpShineRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.138
gInpShineRatio - The downstream loss of rate in a 1 second interval expressed as a fraction of NDR due to a single high impulse noise event (SHINE) impulse noise environment expected by the operator to occur at a probability acceptable for the services. The valid values are all multiples of 0.001 from 0 to 0.1. This field uses 1 to equal 0.001 and 100 to equal 0.1. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

zhoneVdslLineConfUpGinpShineRatio 1.3.6.1.4.1.5504.5.13.1.1.11.1.139
gInpShineRatio - The upstream loss of rate in a 1 second interval expressed as a fraction of NDR due to a single high impulse noise event (SHINE) impulse noise environment expected by the operator to occur at a probability acceptable for the services. The valid values are all multiples of 0.001 from 0 to 0.1. This field uses 1 to equal 0.001 and 100 to equal 0.1. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..255  

zhoneVdslLineConfDownGinpLeftrThreshold 1.3.6.1.4.1.5504.5.13.1.1.11.1.140
gInpLeftrThreshold - The downstream rate Threshold below which the Low Error Free Rate (LEFTR) defect is declared. The threshold used to declare leftr defects is expressed in fraction of the net data rate (NDR). The value 0 is a special value to indicate that the receiver shall use a special value for declaring leftr defect. The minimum valid threshold to declare leftr is ETR/2. The receiver shall ignore threshold values that are less than the minimum and shall use ETR/2 for declaring leftr defect instead. The valid values are all multiples of 0.01 from 0.01 to 0.99. This field uses 1 to equal 0.01 and 99 to equal 0.99.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..99  

zhoneVdslLineConfUpGinpLeftrThreshold 1.3.6.1.4.1.5504.5.13.1.1.11.1.141
gInpLeftrThreshold - The upstream rate Threshold below which the Low Error Free Rate (LEFTR) defect is declared. The threshold used to declare leftr defects is expressed in fraction of the net data rate (NDR). The value 0 is a special value to indicate that the receiver shall use a special value for declaring leftr defect. The minimum valid threshold to declare leftr is ETR/2. The receiver shall ignore threshold values that are less than the minimum and shall use ETR/2 for declaring leftr defect instead. The valid values are all multiples of 0.01 from 0.01 to 0.99. This field uses 1 to equal 0.01 and 99 to equal 0.99.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..99  

zhoneVdslLineConfDownGinpMaxDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.142
gInpMaxDelay - The maximum downstream delay in ms. This is the upper limit for the delay that is added to the transmission delay only caused by retransmissions. Here the receiver and/or the transmitter shall identify and discard all DTUs whose payload cannot be transferred over the reference point at the receiver without violating the delay_max limit. The time stamp shall be the criterion for discarding the DTUs. The processing delay between the U-interface and the retransmission sub-layer of the receiver in the retransmission data path direction shall be excluded from consideration for delay_max in the retransmission data path direction. The valid values are all integers from 1 to 63. ITU-T G.998.4 7.1.1 Control parameters, 7.1.2 Valid configurations, and 8.1.6 Time Stamp.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..63  

zhoneVdslLineConfUpGinpMaxDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.143
gInpMaxDelay - The maximum upstream delay in ms. This is the upper limit for the delay that is added to the transmission delay only caused by retransmissions. Here the receiver and/or the transmitter shall identify and discard all DTUs whose payload cannot be transferred over the reference point at the receiver without violating the delay_max limit. The time stamp shall be the criterion for discarding the DTUs. The processing delay between the U-interface and the retransmission sub-layer of the receiver in the retransmission data path direction shall be excluded from consideration for delay_max in the retransmission data path direction. The valid values are all integers from 1 to 63. ITU-T G.998.4 7.1.1 Control parameters, 7.1.2 Valid configurations, and 8.1.6 Time Stamp.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..63  

zhoneVdslLineConfDownGinpMinDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.144
gInpMinDelay - The minimum downstream delay in ms. This is the lower limit for the delay that is added to the transmission delay caused by retransmissions only. The time stamp shall be used by the outlet shaping function to determine when the payload of the DTU shall be sent to the reference point to meet the delay limits. The outlet shaping function shall minimize the additional delay that may be introduced above delay_ min , and shall never exceed delay_max. The valid values are all integers from 0 to 63. ITU-T G.998.4 7.1.1 Control parameters, 7.1.2 Valid configurations, and 8.1.6 Time Stamp.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..63  

zhoneVdslLineConfUpGinpMinDelay 1.3.6.1.4.1.5504.5.13.1.1.11.1.145
gInpMinDelay - The minimum upstream delay in ms. This is the lower limit for the delay that is added to the transmission delay caused by retransmissions only. The time stamp shall be used by the outlet shaping function to determine when the payload of the DTU shall be sent to the reference point to meet the delay limits. The outlet shaping function shall minimize the additional delay that may be introduced above delay_ min , and shall never exceed delay_max. The valid values are all integers from 0 to 63. ITU-T G.998.4 7.1.1 Control parameters, 7.1.2 Valid configurations, and 8.1.6 Time Stamp.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..63  

zhoneVdslLineConfDownGinpMin 1.3.6.1.4.1.5504.5.13.1.1.11.1.146
ginpMin - The minimum downstream impulse noise protection (INP) against single high impulse noise event (SHINE) in discrete multitone (DMT) symbols. The valid values are all integers from 0 to 63 for system with a sub-carrier spacing of 4.3125 kHz. The valid values are all integers from 0 to 127 for system with a sub-carrier spacing of 8.625 kHz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..127  

zhoneVdslLineConfUpGinpMin 1.3.6.1.4.1.5504.5.13.1.1.11.1.147
ginpMin - The minimum upstream impulse noise protection (INP) against single high impulse noise event (SHINE) in discrete multitone (DMT) symbols. The valid values are all integers from 0 to 63 for system with a sub-carrier spacing of 4.3125 kHz. The valid values are all integers from 0 to 127 for system with a sub-carrier spacing of 8.625 kHz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..127  

zhoneVdslLineConfDownGinpMinRSoverhead 1.3.6.1.4.1.5504.5.13.1.1.11.1.148
gInpMinRSoverhead - This value specifies the downstream bandwidth reserved for RS (reed-solomon) codewords. The minimum guaranteed R/N ratio. The unit is 1/256th and the range is 0..64 (0 to 25%).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..64  

zhoneVdslLineConfUpGinpMinRSoverhead 1.3.6.1.4.1.5504.5.13.1.1.11.1.149
gInpMinRSoverhead - This value specifies the upstream bandwidth reserved for RS (reed-solomon) codewords. The minimum guaranteed R/N ratio. The unit is 1/256th and the range is 0..64 (0 to 25%).
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..64  

zhoneVdslLineConfDownGinpReinCfg 1.3.6.1.4.1.5504.5.13.1.1.11.1.150
gInpReinCfg - The minimum downstream impulse protection against electrical repetitive impulse noise (REIN) in DMT symbols. The valid values are all integers from 0 to 7 for system with a sub-carrier spacing of 4.3125 kHz. The valid values are all integers from 0 to 13 for system with a sub-carrier spacing of 8.625 kHz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

zhoneVdslLineConfUpGinpReinCfg 1.3.6.1.4.1.5504.5.13.1.1.11.1.151
gInpReinCfg - The minimum upstream impulse protection against electrical repetitive impulse noise (REIN) in DMT symbols. The valid values are all integers from 0 to 7 for system with a sub-carrier spacing of 4.3125 kHz. The valid values are all integers from 0 to 13 for system with a sub-carrier spacing of 8.625 kHz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..7  

zhoneVdslLineConfDownGinpReinFreq 1.3.6.1.4.1.5504.5.13.1.1.11.1.152
ginpReinFreq specifies the frequency of REIN inter-arrival time. It is used in the Channel Initialization Policy and on-line reconfiguration procedures. REIN is commonly coupled from electrical power cables appliances drawing power from the AC electrical power network, having a repetition rate of twice the AC power frequency (100 or 120 Hz). The valid values are integers 100 hz or 120 hz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER freq100hz(1), freq120hz(2)  

zhoneVdslLineConfUpGinpReinFreq 1.3.6.1.4.1.5504.5.13.1.1.11.1.153
ginpReinFreq specifies the frequency of REIN inter-arrival time. It is used in the Channel Initialization Policy and on-line reconfiguration procedures. REIN is commonly coupled from electrical power cables appliances drawing power from the AC electrical power network, having a repetition rate of twice the AC power frequency (100 or 120 Hz). The valid values are integers 100 hz or 120 hz. ITU-T G.998.4 7.1.1 Control parameters and 7.1.2 Valid configurations.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER freq100hz(1), freq120hz(2)  

zhoneVdslLineConfDownGinpRtxMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.154
gInpRtxMode - Downstream retransmission Mode (RTX MODE). The RTX_MODE is a configuration parameter used to control activation of retransmission during initialization. This parameter has 4 valid values: FORBIDDEN: ITU-T G.998.4 retransmission not allowed. PREFERRED: ITU-T G.998.4 retransmission is preferred by the operator. (i.e., if ITU-T G.998.4 RTX capability is supported by both XTU's, the XTU's shall select ITU-T G.998.4 operation for this direction). FORCED: Force the use of the ITU-T G.998.4 retransmission. (i.e., if ITU-T G.998.4 RTX capability in this direction is not supported by both XTU's or not selected by the XTU's, an initialization failure shall result). NOTE: Due to the optionality of ITU-T G.998.4 retransmission in upstream direction, the use of FORCED in upstream may lead to initialization failure, even if the XTU is supporting ITU-T G.998.4 (in downstream). TESTMODE: Force the use of the ITU-T G.998.4 retransmission in the test mode described in clause 10.4. (i.e., if ITU-T G.998.4 RTX capability is not supported by both XTU's or not selected by the XTU's, an initialization failure shall result). ITU-T G.998.4 11.1.13 Retransmission Mode (RTX_MODE)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER forbidden(1), preferred(2), forced(3), testmode(4)  

zhoneVdslLineConfUpGinpRtxMode 1.3.6.1.4.1.5504.5.13.1.1.11.1.155
gInpRtxMode - Upstream retransmission Mode (RTX MODE). The RTX_MODE is a configuration parameter used to control activation of retransmission during initialization. This parameter has 4 valid values: FORBIDDEN: ITU-T G.998.4 retransmission not allowed. PREFERRED: ITU-T G.998.4 retransmission is preferred by the operator. (i.e., if ITU-T G.998.4 RTX capability is supported by both XTU's, the XTU's shall select ITU-T G.998.4 operation for this direction). FORCED: Force the use of the ITU-T G.998.4 retransmission. (i.e., if ITU-T G.998.4 RTX capability in this direction is not supported by both XTU's or not selected by the XTU's, an initialization failure shall result). NOTE: Due to the optionality of ITU-T G.998.4 retransmission in upstream direction, the use of FORCED in upstream may lead to initialization failure, even if the XTU is supporting ITU-T G.998.4 (in downstream). TESTMODE: Force the use of the ITU-T G.998.4 retransmission in the test mode described in clause 10.4. (i.e., if ITU-T G.998.4 RTX capability is not supported by both XTU's or not selected by the XTU's, an initialization failure shall result). ITU-T G.998.4 11.1.13 Retransmission Mode (RTX_MODE)
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER forbidden(1), preferred(2), forced(3), testmode(4)  

zhoneVdslLineAlarmConfProfileTable 1.3.6.1.4.1.5504.5.13.1.1.20
This table contains information on the VDSL line alarm configuration. One entry in this table reflects a profile defined by a manager which can be used to configure the VDSL line alarm thresholds. Entries in this table MUST be maintained in a persistent manner.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslLineAlarmConfProfileEntry

zhoneVdslLineAlarmConfProfileEntry 1.3.6.1.4.1.5504.5.13.1.1.20.1
Each entry consists of a list of parameters that represents the configuration of a VDSL line alarm profile. A default profile with an index of 'DEFVAL', will always exist and its parameters will be set to vendor specific values, unless otherwise specified in this document.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslLineAlarmConfProfileEntry  

zhoneVdslLineAlarmConfProfileName 1.3.6.1.4.1.5504.5.13.1.1.20.1.1
The name for this profile as specified by an administrator.
Status: current Access: not-accessible
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

zhoneVdslLineAlarmConfThresh15MinLofs 1.3.6.1.4.1.5504.5.13.1.1.20.1.2
This object configures the threshold for the number of loss of frame seconds (LOFs) within any given 15-minute performance data collection interval. If the value of loss of frame seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfLofsThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinLoss 1.3.6.1.4.1.5504.5.13.1.1.20.1.3
This object configures the threshold for the number of loss of signal seconds (LOSs) within any given 15-minute performance data collection interval. If the value of loss of signal seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfLossThreshNotification notification will be generated. One notification will be sent per interval per endpoint.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinLprs 1.3.6.1.4.1.5504.5.13.1.1.20.1.4
This object configures the threshold for the number of loss of power seconds (LPRs) within any given 15-minute performance data collection interval. If the value of loss of power seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfLprsThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinLols 1.3.6.1.4.1.5504.5.13.1.1.20.1.5
This object configures the threshold for the number of loss of link seconds (LOLs) within any given 15-minute performance data collection interval. If the value of loss of link seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfLolsThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinESs 1.3.6.1.4.1.5504.5.13.1.1.20.1.6
This object configures the threshold for the number of errored seconds (ESs) within any given 15-minute performance data collection interval. If the value of errored seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfEssThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinSESs 1.3.6.1.4.1.5504.5.13.1.1.20.1.7
This object configures the threshold for the number of severely errored seconds (SESs) within any given 15-minute performance data collection interval. If the value of severely errored seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfSessThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfThresh15MinUASs 1.3.6.1.4.1.5504.5.13.1.1.20.1.8
This object configures the threshold for the number of unavailable seconds (UASs) within any given 15-minute performance data collection interval. If the value of unavailable seconds in a particular 15-minute collection interval reaches/exceeds this value, a zhoneVdslPerfUassThreshNotification notification will be generated. No more than one notification will be sent per interval.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..900  

zhoneVdslLineAlarmConfInitFailure 1.3.6.1.4.1.5504.5.13.1.1.20.1.9
This object specifies if a vdslInitFailureNotification notification will be generated if an initialization failure occurs.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneVdslLineAlarmConfProfRowStatus 1.3.6.1.4.1.5504.5.13.1.1.20.1.10
This object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to 'active'. When 'active' is set, the system will validate the profile. Before a profile can be deleted or taken out of service, (by setting this object to 'destroy' or 'outOfService') it must be first unreferenced from all associated lines. An 'active' profile may be modified at any time.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zhoneVdslLineAlarmConfThresh1DayLofs 1.3.6.1.4.1.5504.5.13.1.1.20.1.11
This object configures the threshold for the number of loss of frame seconds (LOFs) within any given 1-day performance data collection interval. If the value of loss of frame seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfLofsThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayLoss 1.3.6.1.4.1.5504.5.13.1.1.20.1.12
This object configures the threshold for the number of loss of signal seconds (LOSs) within any given 1-day performance data collection interval. If the value of loss of signal seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfLossThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayLprs 1.3.6.1.4.1.5504.5.13.1.1.20.1.13
This object configures the threshold for the number of loss of power seconds (LPRs) within any given 1-day performance data collection interval. If the value of loss of power seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfLprsThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayLols 1.3.6.1.4.1.5504.5.13.1.1.20.1.14
This object configures the threshold for the number of loss of link seconds (LOLs) within any given 1-day performance data collection interval. If the value of loss of link seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfLolsThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayESs 1.3.6.1.4.1.5504.5.13.1.1.20.1.15
This object configures the threshold for the number of errored seconds (ESs) within any given 1-day performance data collection interval. If the value of errored seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfEssThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DaySESs 1.3.6.1.4.1.5504.5.13.1.1.20.1.16
This object configures the threshold for the number of severely errored seconds (SESs) within any given 1-day performance data collection interval. If the value of severely errored seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfSessThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayUASs 1.3.6.1.4.1.5504.5.13.1.1.20.1.17
This object configures the threshold for the number of unavailable seconds (UASs) within any given 1-day performance data collection interval. If the value of unavailable seconds in a particular 1-day collection interval reaches/exceeds this value, a zhoneVdslPerfUasThreshNotification notification will be generated. No more than one notification will be sent per interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..86400  

zhoneVdslLineAlarmConfThresh1DayInitFailure 1.3.6.1.4.1.5504.5.13.1.1.20.1.18
This object specifies if a vdslThresh1DayInitFailureNotification notification will be generated if an initialization failure occurs.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zhoneVdslCustomNotchConfProfileTable 1.3.6.1.4.1.5504.5.13.1.1.21
This table contains HAM (Handheld Amateur Radio) custom notch information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslCustomNotchConfProfileEntry

zhoneVdslCustomNotchConfProfileEntry 1.3.6.1.4.1.5504.5.13.1.1.21.1
Each VDSL port can have custom notches.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslCustomNotchConfProfileEntry  

zhoneVdslCustomNotchConfId 1.3.6.1.4.1.5504.5.13.1.1.21.1.1
Each VDSL2 port can have eight (8) custom notch pairs.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 1..8  

zhoneVdslCustomNotchConfStart 1.3.6.1.4.1.5504.5.13.1.1.21.1.2
Specifies the start frequency of custom HAM (Handheld Amateur Radio) notch. zhoneVdslCustomNotchConfStart MUST be less than or equal to zhoneVdslCustomNotchConfStop.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslCustomNotchConfStop 1.3.6.1.4.1.5504.5.13.1.1.21.1.3
Specifies the end frequency of custom HAM (Handheld Amateur Radio) notch. zhoneVdslCustomNotchConfStop MUST be greater than or equal to zhoneVdslCustomNotchConfStart.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32 0..200000  

zhoneVdslVectDataTable 1.3.6.1.4.1.5504.5.13.1.1.22
Used to retrieve the vectoring packet counts.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVdslVectDataEntry

zhoneVdslVectDataEntry 1.3.6.1.4.1.5504.5.13.1.1.22.1
Vectoring Packet statistics data
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVdslVectDataEntry  

zhoneVdslVectDataEsDsCounter 1.3.6.1.4.1.5504.5.13.1.1.22.1.1
Error Sample Downstream Packet Counter
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslVectDataEsUsCounter 1.3.6.1.4.1.5504.5.13.1.1.22.1.2
Error Sample Upstream Packet Counter
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslVectDataIsDsFeValid 1.3.6.1.4.1.5504.5.13.1.1.22.1.3
Is Downstream Fe Valid
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslVectDataEsFeDsCounter 1.3.6.1.4.1.5504.5.13.1.1.22.1.4
Error Sample Fe Downstream Counter
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zhoneVdslConformance 1.3.6.1.4.1.5504.5.13.1.3
OBJECT IDENTIFIER    

zhoneVdslGroups 1.3.6.1.4.1.5504.5.13.1.3.1
OBJECT IDENTIFIER    

zhoneVdslGroup 1.3.6.1.4.1.5504.5.13.1.3.1.1
A collection of objects providing information about a VDSL Line.
Status: current Access: read-only
OBJECT-GROUP    

zhoneVdslNotificationGroup 1.3.6.1.4.1.5504.5.13.1.3.1.2
This group supports notifications of significant conditions associated with VDSL Lines.
Status: current Access: read-only
NOTIFICATION-GROUP    

zhoneVdslCompliances 1.3.6.1.4.1.5504.5.13.1.3.2
OBJECT IDENTIFIER    

zhoneVdslLineMibCompliance 1.3.6.1.4.1.5504.5.13.1.3.2.1
The compliance statement for SNMP entities which manage VDSL interfaces.
Status: current Access: read-only
MODULE-COMPLIANCE