Zhone-VOICE-ANALOG-IF-MIB

File: Zhone-VOICE-ANALOG-IF-MIB.mib (70385 bytes)

Imported modules

IF-MIB SNMPv2-SMI SNMPv2-TC
Zhone Zhone-TC

Imported symbols

ifIndex InterfaceIndex Integer32
Counter32 OBJECT-TYPE MODULE-IDENTITY
TruthValue zhonePhysical zhoneModules
ZhoneRowStatus

Defined Types

ZhoneVaIfCfgEntry  
SEQUENCE    
  zhoneVaIfCfgImpedance INTEGER
  zhoneVaIfCfgReceiveTLP INTEGER
  zhoneVaIfCfgTransmitTLP INTEGER
  zhoneVaIfCfgTrunkConditioning INTEGER
  zhoneVaIfCfgLineType INTEGER
  zhoneVaIfCfgIntegratedDSP TruthValue
  zhoneVaIfCfgLineCapabilities BITS
  zhoneVaIfCfgMaintenanceMode INTEGER
  zhoneVaIfCfgPCMEncoding INTEGER
  zhoneVaIfCfgReceiveTLPNum INTEGER
  zhoneVaIfCfgTransmitTLPNum INTEGER
  zhoneVaIfCfgLoopCurrent INTEGER
  zhoneVaIfCfgRingVoltage INTEGER

ZhoneVaIfStatusEntry  
SEQUENCE    
  zhoneVaIfStatusSignalErrors Counter32
  zhoneVaIfStatusInfoType INTEGER

ZhoneVaIfFXSCfgEntry  
SEQUENCE    
  zhoneVaIfFXSCfgSignalType INTEGER
  zhoneVaIfFXSRingFrequency INTEGER
  zhoneVaIfFXSRingBack INTEGER

ZhoneVaIfFXSStatusEntry  
SEQUENCE    
  zhoneVaIfFXSHookStatus INTEGER
  zhoneVaIfFXSRingActive TruthValue
  zhoneVaIfFXSRingGround TruthValue
  zhoneVaIfFXSTipGround TruthValue

ZhoneVaIfFXSTimingEntry  
SEQUENCE    
  zhoneVaIfFXSTimingDigitDuration Integer32
  zhoneVaIfFXSTimingInterDigitDuration Integer32

ZhonePotsRingEntry  
SEQUENCE    
  zhonePotsRingIfIndex InterfaceIndex
  zhonePotsRingRingingCadence INTEGER
  zhonePotsRingTimer Integer32
  zhonePotsRingRowStatus ZhoneRowStatus

ZhoneVaIfFXOCfgEntry  
SEQUENCE    
  zhoneVaIfFXOCfgSignalType INTEGER
  zhoneVaIfFXOCfgNumberRings Integer32
  zhoneVaIfFXOCfgSupDisconnect TruthValue
  zhoneVaIfFXOCfgDialType INTEGER

ZhoneVaIfFXOStatusEntry  
SEQUENCE    
  zhoneVaIfFXOHookStatus INTEGER
  zhoneVaIfFXORingDetect TruthValue
  zhoneVaIfFXORingGround TruthValue
  zhoneVaIfFXOTipGround TruthValue

ZhoneVaIfFXOTimingEntry  
SEQUENCE    
  zhoneVaIfFXOTimingDigitDuration Integer32
  zhoneVaIfFXOTimingInterDigitDuration Integer32
  zhoneVaIfFXOTimingPulseRate Integer32
  zhoneVaIfFXOTimingPulseInterDigitDuration Integer32

ZhoneVaIfEMCfgEntry  
SEQUENCE    
  zhoneVaIfEMCfgSignalType INTEGER
  zhoneVaIfEMCfgOperation INTEGER
  zhoneVaIfEMCfgType INTEGER
  zhoneVaIfEMCfgDialType INTEGER

ZhoneVaIfEMStatusEntry  
SEQUENCE    
  zhoneVaIfEMInSeizureActive TruthValue
  zhoneVaIfEMOutSeizureActive TruthValue

ZhoneVaIfEMTimingEntry  
SEQUENCE    
  zhoneVaIfEMTimingDigitDuration Integer32
  zhoneVaIfEMTimingInterDigitDuration Integer32
  zhoneVaIfEMTimingPulseRate Integer32
  zhoneVaIfEMTimingPulseInterDigitDuration Integer32
  zhoneVaIfEMTimingClearWaitDuration Integer32
  zhoneVaIfEMTimingMaxWinkWaitDuration Integer32
  zhoneVaIfEMTimingMaxWinkDuration Integer32
  zhoneVaIfEMTimingDelayStart Integer32
  zhoneVaIfEMTimingMaxDelayDuration Integer32
  zhoneVaIfEMTimingMinDelayPulseWidth Integer32

Defined Values

zhoneVoiceAnalogIf-MIB 1.3.6.1.4.1.5504.6.13
Analog Voice Interface MIB module. This MIB manages the E&M, FXO, FXS Interfaces in the Zhone's product.
MODULE-IDENTITY    

zhoneVaIfObjects 1.3.6.1.4.1.5504.5.6
OBJECT IDENTIFIER    

zhoneVaIfGeneralObjects 1.3.6.1.4.1.5504.5.6.1
OBJECT IDENTIFIER    

zhoneVaIfCfgTable 1.3.6.1.4.1.5504.5.6.1.1
The Analog Voice Standard Configuration Table. It contains the standard configuration information of the analog telephony interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfCfgEntry

zhoneVaIfCfgEntry 1.3.6.1.4.1.5504.5.6.1.1.1
An entry in the configuration table for each voice analog interface. The entry is created when the voice analog hardware is detected.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfCfgEntry  

zhoneVaIfCfgImpedance 1.3.6.1.4.1.5504.5.6.1.1.1.1
Specifies the terminating impedance of voice analog interfaces. other - none of the following; arbitrary, within limits, for special cases. ohms600Real - 600 Ohms. ohms600Complex - 600 Ohms + 2.16uF ohms900Complex - 900 Ohms + 2.16uF. ohmsComplex1 - Not Supported. ohmsComplex2 - Not Supported. Default value is ohms600Complex.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), ohms600Real(2), ohms600Complex(3), ohms900Complex(4), ohmsComplex1(5), ohmsComplex2(6)  

zhoneVaIfCfgReceiveTLP 1.3.6.1.4.1.5504.5.6.1.1.1.2
Receive Transmission Level Point (RTLP) settings control the amount gain or loss added to the incoming signal after it is decoded to analog. to increase the signal level set the RTLP setting to higher values. The default is fxsRtlpN6db. Rtlpnummeric selects entering the actual value in zhoneVaIFCfgReceiveTLPNum.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fxsRtlpN9db(1), fxsRtlpN8db(2), fxsRtlpN7db(3), fxsRtlpN6db(4), fxsRtlpN5db(5), fxsRtlpN4db(6), fxsRtlpN3db(7), fxsRtlpN2db(8), fxsRtlpN1db(9), fxsRtlp0db(10), fxsRtlp1db(11), fxsRtlp2db(12), fxsRtlp3db(13), rTlpNummeric(14)  

zhoneVaIfCfgTransmitTLP 1.3.6.1.4.1.5504.5.6.1.1.1.3
In case of FXO, it specifies FXO attenuation and default value is 0dB(fxsTtlp0db). In case of FXS this setting controls the amount of gain or loss added to a voice signal from CPE before it is encoded to digital PCM. To increase the signal level, reduce the TTLP setting to lower value. The default is fxsTtlp0db. Ttlpnummeric selects entering the actual value in zhoneVaIFCfgTransmitTLPNum.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fxsTtlp9db(1), fxsTtlp8db(2), fxsTtlp7db(3), fxsTtlp6db(4), fxsTtlp5db(5), fxsTtlp4db(6), fxsTtlp3db(7), fxsTtlp2db(8), fxsTtlp1db(9), fxsTtlp0db(10), fxsTtlpN1db(11), fxsTtlpN2db(12), fxsTtlpN3db(13), tTlpNummeric(14)  

zhoneVaIfCfgTrunkConditioning 1.3.6.1.4.1.5504.5.6.1.1.1.4
The trunk conditioning setting specifies whether the FXS/FXO port should send the idle pattern to the network upon declaration of a Carrier Group Alarm(CGA) on the WAN link to which the port is assigned . In most cases leave the trunk conditioning setting at its default setting(off).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), idle(2), busy(3)  

zhoneVaIfCfgLineType 1.3.6.1.4.1.5504.5.6.1.1.1.5
The Card type FXS, FXO, EM, EBS. Entries in the table will be created or deleted on the basis of zhoneVaIfCfgLineType in the zhoneVaIfCfgTable and we are not using rowStatus entry for this . The tables which are augument to the above mentioned table will be created by RP only and they can be read or modified by user later.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER fxs(1), fxo(2), em(3), ebs(4)  

zhoneVaIfCfgIntegratedDSP 1.3.6.1.4.1.5504.5.6.1.1.1.6
Indicates whether the interface has an integrated Digital Signal processing (DSP) unit.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfCfgLineCapabilities 1.3.6.1.4.1.5504.5.6.1.1.1.7
The Interface types supported on this interface. This is a bit-map of possible types. This variable can be used to determine zhoneVaIfCfgLineType.
Status: current Access: read-only
OBJECT-TYPE    
  BITS fxs(0), fxo(1), em(2)  

zhoneVaIfCfgMaintenanceMode 1.3.6.1.4.1.5504.5.6.1.1.1.8
Indicates the maintenance modes of the Analog voice interface. loopback options for Fxo and Fxs cards (Zhone specific) ------------------------------------------------------- CODEC T1/E1 DS0 --------------------------- <------- <--------------- ----------------- Network PCM Bus ^ Digital ^ | to analog Converter| | | | | | | Digital loopback Analog loopback | | -------> -------- ->---------------------------------------------> off(1) - the interface is not in maintenance mode. ifDigitalLoopback(2) This mode is set by the managed system to perform the Digital loopback test. ifAnalogLoopback(3) This mode is set by the managed system to perform the Analog loopback test.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), ifDigitalLoopback(2), ifAnalogLoopback(3)  

zhoneVaIfCfgPCMEncoding 1.3.6.1.4.1.5504.5.6.1.1.1.9
alaw(1) :for E1 mulaw(2) : for T1
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER alaw(1), mulaw(2)  

zhoneVaIfCfgReceiveTLPNum 1.3.6.1.4.1.5504.5.6.1.1.1.10
Receive Transmission Level Point (RTLP) settings control the amount gain or loss added to the incoming signal after it is decoded to analog. to incrase the signal level set the RTLP setting to higher values. The default is 0 dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -160..85  

zhoneVaIfCfgTransmitTLPNum 1.3.6.1.4.1.5504.5.6.1.1.1.11
Transmit Transmission Level Point controls the amount of gain or loss added to a voice signal from CPE before it is encoded to digital PCM. To increase the signal level, reduce the TTLP setting to lower value. The default is 0dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER -175..70  

zhoneVaIfCfgLoopCurrent 1.3.6.1.4.1.5504.5.6.1.1.1.12
To set the loop current value for a subscriber
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 20..44  

zhoneVaIfCfgRingVoltage 1.3.6.1.4.1.5504.5.6.1.1.1.13
To set the ring voltage for a subscriber.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER b85vrms(1), b75vrms(2), b92vrms(3)  

zhoneVaIfStatusTable 1.3.6.1.4.1.5504.5.6.1.2
The Analog Voice Status Table. It contains general information about the status of Analog Telephony interface including the error statistics.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfStatusEntry

zhoneVaIfStatusEntry 1.3.6.1.4.1.5504.5.6.1.2.1
An entry in the status table for each Analog voice interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfStatusEntry  

zhoneVaIfStatusSignalErrors 1.3.6.1.4.1.5504.5.6.1.2.1.1
Accumulated number of signaling protocol errors that are detected in the interface since system startup.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zhoneVaIfStatusInfoType 1.3.6.1.4.1.5504.5.6.1.2.1.2
The information transfer services for the current call. none - no information transfer service, this is set befgore the first call is made on the interface. voice - analog voice. g3Fax - Group 3 FAX.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notype(1), voice(2), g3Fax(3)  

zhoneVaIfFXSObjects 1.3.6.1.4.1.5504.5.6.2
OBJECT IDENTIFIER    

zhoneVaIfFXSCfgTable 1.3.6.1.4.1.5504.5.6.2.1
The FXS standard configuration table. It contains FXS configuration parameters, one entry per FXS interface. The configuration information of this table is set by hardware with its default setting or CLI during the hardware installation time.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXSCfgEntry

zhoneVaIfFXSCfgEntry 1.3.6.1.4.1.5504.5.6.2.1.1
An entry in the standard configuration table for each FXS interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXSCfgEntry  

zhoneVaIfFXSCfgSignalType 1.3.6.1.4.1.5504.5.6.2.1.1.1
the signaling type of FXS interface. fxsLoopStart - loop start. fxsGroundStart - ground start. fxsLoopStartFd fxsGroundStartAutomatic - Used with equipment requiring fast response time to the Central Office. fxsGroundStartImmediate - Used with equipment requiring fast response time to the station or PBX. fxsdnLoopStart- loop start in fxsdn mode fxsdnLoopStartFd fxsdnGroundStart- Ground start in fxsdn mode fxsdnGroundStartImmediate - Ground start immediate in fxsdn mode fxsdnwinkLoopStart - loop start in fxsdnwink (foreign exchange subscriber - defined wink start operation) this option proved the same type of signalling as FXSDN and provides 150 millisecond delay then 200 ms wink ack to the central office when fxs port sees an off hook condition from central office . The system requires a ringing generator for this option. fxsdnwinkLoopStartFd fxsdnwinkGroundStart- Ground start in FXSDNWINK mode fxsdnwinkGroundStartImmediate - Ground start immediate in FXSDNWINK mode. fxstr08SingleParty - TR08 is Frame format signalling and data link as defined in TR-TSY-00008 Mode 1 for circuits using AT & T SLC-96 facilities. this option is for single party service , this option connects the port to one way out going trunks from a PBX , CENTEREX, key system , ot telephone set to an SLC channel. The SLC96 mode also must be active on the associated WAN interface. fxstr08UniversalVoiceGrade - Toll quality voice for SLC-96 fxstr08UniversalVoiceGradeAutomatic- Used with some non - Bell switches for SLC-96 The default value of this object is fxsLoopStart(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fxsLoopStart(1), fxsGroundStart(2), fxsLoopStartFd(3), fxsGroundStartAutomatic(4), fxsGroundStartImmediate(5), fxsdnLoopStart(6), fxsdnLoopStartFd(7), fxsdnGroundStart(8), fxsdnGroundStartImmediate(9), fxsdnwinkLoopStart(10), fxsdnwinkLoopStartFd(11), fxsdnwinkGroundStart(12), fxsdnwinkGroundStartImmediate(13), fxstr08SingleParty(14), fxstr08UniversalVoiceGrade(15), fxstr08UniversalVoiceGradeAutomatic(16)  

zhoneVaIfFXSRingFrequency 1.3.6.1.4.1.5504.5.6.2.1.1.2
the ring frequency to be used in the FXS interface. ringFrequency25 - ring frequency 25 Hertz. ringFrequency50 - ring frequency 50 Hertz. ringFrequency20 - ring frequency 20 Hertz.(Default) ringFrequency30 - ring frequency 30 Hertz.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ringFrequency25(1), ringFrequency50(2), ringFrequency20(3), ringFrequency30(4)  

zhoneVaIfFXSRingBack 1.3.6.1.4.1.5504.5.6.2.1.1.3
the ring back is requested if this variable is set to on.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER on(1), off(2)  

zhoneVaIfFXSStatusTable 1.3.6.1.4.1.5504.5.6.2.2
The Foreign Exchange Station (FXS) interface Status Table. It contains hook status, ring active and other states of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXSStatusEntry

zhoneVaIfFXSStatusEntry 1.3.6.1.4.1.5504.5.6.2.2.1
An entry in the status table for each FXS interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXSStatusEntry  

zhoneVaIfFXSHookStatus 1.3.6.1.4.1.5504.5.6.2.2.1.1
This object contains the hook status of FXS interface. onHook - the connected equipment(e.g., phone) is onHook. offHook - the connected equipment is offHook.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onHook(1), offHook(2)  

zhoneVaIfFXSRingActive 1.3.6.1.4.1.5504.5.6.2.2.1.2
This object contains the outgoing ring active indication. If the object value is true, then the interface is currently generating ring out to the Key Telephone System (KTS) or Plain Old Telephone (POT); otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXSRingGround 1.3.6.1.4.1.5504.5.6.2.2.1.3
This object contains the incoming ring ground indication. It is only valid when the zvaIfFXSCfgSignalType is fxsGroundStart. If the object is true, then the interface is presenting a ring ground to the connected equipment; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXSTipGround 1.3.6.1.4.1.5504.5.6.2.2.1.4
This object contains the incoming tip ground indication. It is only valid when the zvaIfFXSCfgSignalType is fxsGroundStart. If the object is true, then the interface is detecting a tip ground at the interface; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXSTimingTable 1.3.6.1.4.1.5504.5.6.2.3
The FXS interface Timing Parameters table. It contains the configuration of the various FXS signaling protocol timing parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXSTimingEntry

zhoneVaIfFXSTimingEntry 1.3.6.1.4.1.5504.5.6.2.3.1
An entry in the FXS Timing Parameters Table for each FXS interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXSTimingEntry  

zhoneVaIfFXSTimingDigitDuration 1.3.6.1.4.1.5504.5.6.2.3.1.1
Outgoing DTMF digit duration in milliseconds. The default value of this object is 100 milliseconds. This field is not supported.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhoneVaIfFXSTimingInterDigitDuration 1.3.6.1.4.1.5504.5.6.2.3.1.2
Outgoing DTMF inter-digit duration in milliseconds. The default value of this object is 100 milliseconds. This field is not supported.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhonePotsRingTable 1.3.6.1.4.1.5504.5.6.2.4
Table to execute diagnostic potsring command. Row in table with non-zero timer will ring pots port. Currently, maximum of 4 rows at a time are supported.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhonePotsRingEntry

zhonePotsRingEntry 1.3.6.1.4.1.5504.5.6.2.4.1
potsring table entry
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  ZhonePotsRingEntry  

zhonePotsRingIfIndex 1.3.6.1.4.1.5504.5.6.2.4.1.1
Physical pots interface.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  InterfaceIndex  

zhonePotsRingRingingCadence 1.3.6.1.4.1.5504.5.6.2.4.1.2
Ring cadence to use in test.
Status: deprecated Access: read-create
OBJECT-TYPE    
  INTEGER ring-cadence-r0(1), ring-cadence-r1(2), ring-cadence-r2(3), ring-cadence-r3(4), ring-cadence-r4(5), ring-cadence-r5(6), ring-cadence-r6(7), ring-cadence-r7(8), ring-cadence-common(9), ring-cadence-splash(10)  

zhonePotsRingTimer 1.3.6.1.4.1.5504.5.6.2.4.1.3
Time in seconds to continue ringing.
Status: deprecated Access: read-create
OBJECT-TYPE    
  Integer32 1..9999  

zhonePotsRingRowStatus 1.3.6.1.4.1.5504.5.6.2.4.1.4
Row status
Status: deprecated Access: read-create
OBJECT-TYPE    
  ZhoneRowStatus  

zhoneVaIfFXOObjects 1.3.6.1.4.1.5504.5.6.3
OBJECT IDENTIFIER    

zhoneVaIfFXOCfgTable 1.3.6.1.4.1.5504.5.6.3.1
The FXO standard configuration table. It contains FXO configuration parameters, one entry per FXO interface. The configuration information of this table is set by hardware with its default setting or CLI during the hardware installation time.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXOCfgEntry

zhoneVaIfFXOCfgEntry 1.3.6.1.4.1.5504.5.6.3.1.1
An entry in the standard configuration table for each FXO interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXOCfgEntry  

zhoneVaIfFXOCfgSignalType 1.3.6.1.4.1.5504.5.6.3.1.1.1
the signaling type of FXO interface. fxoLoopStart - loop start. fxoGroundStart - ground start. fxodpt- Dial Pulse Terminating , this option allows the unit to attach to incoming one way trunks from a PBX , key system or a telephone set.. The default value of this object is fxoLoopStart(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER fxoLoopStart(1), fxoGroundStart(2), fxodpt(3)  

zhoneVaIfFXOCfgNumberRings 1.3.6.1.4.1.5504.5.6.3.1.1.2
The number of rings detected before closing loop. The default value of this object is 1 ring.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

zhoneVaIfFXOCfgSupDisconnect 1.3.6.1.4.1.5504.5.6.3.1.1.3
Specifies whether a supervisory disconnect signal (CPC) will be presented to the interface when the connected party at the interface hangs up. The default value of this object is 'true'.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXOCfgDialType 1.3.6.1.4.1.5504.5.6.3.1.1.4
Specifies the out dialing type of FXO interface. dtmf - DTMF digit. pulse - pulse. The default value of this object is dtmf(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

zhoneVaIfFXOStatusTable 1.3.6.1.4.1.5504.5.6.3.2
The Foreign Exchange Office (FXO) interface Status Table. It contains hook status, ring detection and other states of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXOStatusEntry

zhoneVaIfFXOStatusEntry 1.3.6.1.4.1.5504.5.6.3.2.1
An entry in the status table for each FXO interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXOStatusEntry  

zhoneVaIfFXOHookStatus 1.3.6.1.4.1.5504.5.6.3.2.1.1
This object contains the hook status of FXO interface. onHook - Present the onHook to the connected equipment. offHook - Present the offHook to the connected equipment.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER onHook(1), offHook(2)  

zhoneVaIfFXORingDetect 1.3.6.1.4.1.5504.5.6.3.2.1.2
This object contains the ring detect indication. If the value is true, then the interface detects ring from PBX or CO; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXORingGround 1.3.6.1.4.1.5504.5.6.3.2.1.3
This object contains the incoming ring ground indication. It is only valid when the zvaIfFXOCfgSignalType is fxoGroundStart. If the object is true, then the interface is presenting a ring ground to the connected equipment; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXOTipGround 1.3.6.1.4.1.5504.5.6.3.2.1.4
This object contains the incoming tip ground indication. It is only valid when the zvaIfFXOCfgSignalType is fxoGroundStart. If the object is true, then the interface is detecting a tip ground at the interface; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfFXOTimingTable 1.3.6.1.4.1.5504.5.6.3.3
The FXO interface Timing Parameters table. It contains the configuration of the various FXO signaling protocol timing parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfFXOTimingEntry

zhoneVaIfFXOTimingEntry 1.3.6.1.4.1.5504.5.6.3.3.1
An entry in the FXO Timing Parameters Table for each FXO interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfFXOTimingEntry  

zhoneVaIfFXOTimingDigitDuration 1.3.6.1.4.1.5504.5.6.3.3.1.1
Outgoing DTMF digit duration in milliseconds. The default value of this object is 100 msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhoneVaIfFXOTimingInterDigitDuration 1.3.6.1.4.1.5504.5.6.3.3.1.2
Outgoing DTMF inter-digit duration in milliseconds. The default value of this object is 100 msec.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhoneVaIfFXOTimingPulseRate 1.3.6.1.4.1.5504.5.6.3.3.1.3
Outgoing pulse dialing rate in pulses per second (pps). The default value of this object is 10 pps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..20  

zhoneVaIfFXOTimingPulseInterDigitDuration 1.3.6.1.4.1.5504.5.6.3.3.1.4
Outgoing pulse dialing inter-digit timing in milliseconds. The default value of this object is 500 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..1000  

zhoneVaIfEMObjects 1.3.6.1.4.1.5504.5.6.4
OBJECT IDENTIFIER    

zhoneVaIfEMCfgTable 1.3.6.1.4.1.5504.5.6.4.1
The E&M standard configuration table. It contains the current setting of E&M configurable parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfEMCfgEntry

zhoneVaIfEMCfgEntry 1.3.6.1.4.1.5504.5.6.4.1.1
An entry in the standard configuration table for each E&M tie trunk interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfEMCfgEntry  

zhoneVaIfEMCfgSignalType 1.3.6.1.4.1.5504.5.6.4.1.1.1
The signaling type of E&M tie trunk interface. winkStart - the calling side seizes the line by going off-hook on its E lead but waits for a short off-hook 'wink' indication on its M lead from the called side before sending address information as DTMF digits. immediateDial - the calling side seizes the line by going off-hook on its E lead and sends sends address information as DTMF digits. delayDial - the calling side seizes the line by going off-hook on its E lead. After a timing interval, the calling side looks at the supervision from the called side. If the supervision is on-hook, the calling side starts sending information as DTMF digits; otherwise, the calling side waits until the called side goes on-hook and then starts sending address information. The default value of this object is winkStart(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER winkStart(1), immediateDial(2), delayDial(3)  

zhoneVaIfEMCfgOperation 1.3.6.1.4.1.5504.5.6.4.1.1.2
Specify the operation of the E&M signal. twoWires - 2-wire operation. fourWires - 4-wire operation. The default value of this object is twoWires(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER twoWires(1), fourWires(2)  

zhoneVaIfEMCfgType 1.3.6.1.4.1.5504.5.6.4.1.1.3
Specifies the E&M Lead Signaling type. LEGEND: V = -48V /\/\/ = detector/resister X = normally open relay contact + = normally closed relay contact G = ground SB = Signal Battery SG = Signal Ground typeI - Leads: E (output, relay to ground) M (input, referenced to ground) The tie line equipment (switch/router/etc) generates the E-signal to the PBX type grounding the E-lead. The tie line equipment detects the M-signal by detecting current flow to ground. A common ground must exist between the line equipment and the PBX. PBX | TIE LINE | E: V--/\/\/---|-----X----G | M: V----X-----|---/\/\/--G typeII - Leads: E (output, relay to SG) M (input, referenced to ground) SB (feed for M, connected to -48V) SG (return for E, galvanically isolated from ground) This interface requires no common ground between the equipment, thus avoiding ground loop noise problems. E-signal is generated toward the PBX by connecting it to SG. M-signal is indicated by the PBX connecting it to SB. While this interface does NOT require a common ground, it does have the tendency to inject noise into the audio paths since it is asymmetrical with respect to current flow between devices. PBX | TIE LINE | E: V--/\/\/---|-----X---- | | SG: G----------|---------- | M: ----X-----|---/\/\/--G | | SB: ----------|----------V typeIII - Leads: E (output, relay to ground) M (input, referenced to ground) SB (connected to -48V) SG (connected to ground) This interface operates similar to type I with respect to the E-signal. The M-signal, however, is indicated by the PBX connecting it to SB on assertion, and alternately connecting it to SG during inactivity. Unfortunately, a common ground must be shared between the equipment. PBX | TIE LINE | E: V--/\/\/---|-----X----G | SG: ----------|----------G + | M: ----------|---/\/\/--G X | SB: ----------|----------V typeIV - Leads: E (output, relay to SG) M (input, referenced to -48V) SB (feed for M, connected to ground) SG (return for E, galvanically isolated from ground) This interface is fully symmetrical; it does not require a common ground, does not inject noise into audio paths, and can be connected back to back by swapping E/SG for M/SB. E-signal is indicated to the PBX by connecting it to SG. M-signal is provided by the PBX connecting it to SB. PBX | TIE LINE | E: V--/\/\/---|-----X---- | | SG: G----------|---------- | M: ----------|---/\/\/--V X | SB: ----------|----------G typeV - Leads: E (output, relay to ground) M (input, referenced to -48V) Type V line equipment indicates E-signal to the PBX by grounding the E-lead. The PBX indicates M-signal by grounding the M-lead. This interface does require a common ground, but does allow back to back connections by swapping E for M. This interface is quasi-symmetric in that while the line is up, current flow is more or less equal between the PBX and line equipment. But noise injection is still a problem. PBX | TIE LINE | E: V--/\/\/---|-----X----G | M: G-----X----|---/\/\/--V | The default value of this object is typeI(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER typeI(1), typeII(2), typeIII(3), typeIV(4), typeV(5), typeIIE(6), typeIIM(7), typeTO(8)  

zhoneVaIfEMCfgDialType 1.3.6.1.4.1.5504.5.6.4.1.1.4
Specifies the out dialing type of E&M interface. dtmf - DTMF digit. pulse - pulse. The default value of this object is dtmf(1).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER dtmf(1), pulse(2)  

zhoneVaIfEMStatusTable 1.3.6.1.4.1.5504.5.6.4.2
The E&M interface Table. The table contains the status of the E&M tie trunk interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfEMStatusEntry

zhoneVaIfEMStatusEntry 1.3.6.1.4.1.5504.5.6.4.2.1
An entry in the status table for each E&M interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfEMStatusEntry  

zhoneVaIfEMInSeizureActive 1.3.6.1.4.1.5504.5.6.4.2.1.1
This object contains the incoming seizure state of the E&M interface. If the value is true, then the interface has an incoming trunk seizure active; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfEMOutSeizureActive 1.3.6.1.4.1.5504.5.6.4.2.1.2
This object contains the outgoing seizure state of the E&M interface. If the value is true, then the interface has an outgoing trunk seizure active; otherwise, it doesn't.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

zhoneVaIfEMTimingTable 1.3.6.1.4.1.5504.5.6.4.3
The E&M tie trunk Timing Parameters table. It contains the configuration of the various E&M signaling protocol timing parameters.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZhoneVaIfEMTimingEntry

zhoneVaIfEMTimingEntry 1.3.6.1.4.1.5504.5.6.4.3.1
An entry in the E&M Timing Parameters Table for each E&M interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZhoneVaIfEMTimingEntry  

zhoneVaIfEMTimingDigitDuration 1.3.6.1.4.1.5504.5.6.4.3.1.1
Outgoing DTMF digit duration in milliseconds. The default value of this object is 100 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhoneVaIfEMTimingInterDigitDuration 1.3.6.1.4.1.5504.5.6.4.3.1.2
Outgoing DTMF inter-digit duration in milliseconds. The default value of this object is 100 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..500  

zhoneVaIfEMTimingPulseRate 1.3.6.1.4.1.5504.5.6.4.3.1.3
Outgoing pulse dialing rate in pulses per second (pps). The default value of this object is 10 pps.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..20  

zhoneVaIfEMTimingPulseInterDigitDuration 1.3.6.1.4.1.5504.5.6.4.3.1.4
Outgoing Pulse dialing inter-digit timing in milliseconds. The default value of this object is 500 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..1000  

zhoneVaIfEMTimingClearWaitDuration 1.3.6.1.4.1.5504.5.6.4.3.1.5
Time of Inactive seizure signal to declare call cleared. The default value of this object is 400 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 200..2000  

zhoneVaIfEMTimingMaxWinkWaitDuration 1.3.6.1.4.1.5504.5.6.4.3.1.6
Maximum time to wait from the outgoing seizure of the line to the time of sending out a wink-pulse. The default value of this object is 200 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..5000  

zhoneVaIfEMTimingMaxWinkDuration 1.3.6.1.4.1.5504.5.6.4.3.1.7
Maximum outgoing wink duration (between the wink-pulse leading edge and trailing edge) for wink start signaling. The default value of this object is 200 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..3000  

zhoneVaIfEMTimingDelayStart 1.3.6.1.4.1.5504.5.6.4.3.1.8
Minimum time to wait from outgoing seizure to out-dialing digits for delay start signaling. The default value of this object is 300 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 20..2000  

zhoneVaIfEMTimingMaxDelayDuration 1.3.6.1.4.1.5504.5.6.4.3.1.9
Maximum time to wait from outgoing seizure to out-dialing digits. If the far end does not allow to send digits after the duration specified in the object, a reorder tone will be sent to the calling party. The default value of this object is 2000 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..5000  

zhoneVaIfEMTimingMinDelayPulseWidth 1.3.6.1.4.1.5504.5.6.4.3.1.10
Minimum delay-dial pulse duration for incoming call. If the value of this object is 0, then no delay-dial is sent to the far end for the incoming call. The default value of this object is 140 milliseconds.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 140..5000