ZYXEL-SFLOW-MIB

File: ZYXEL-SFLOW-MIB.mib (9352 bytes)

Imported modules

RFC1155-SMI SNMPv2-SMI SNMPv2-TC
RFC1213-MIB P-BRIDGE-MIB Q-BRIDGE-MIB
BRIDGE-MIB IF-MIB SNMP-FRAMEWORK-MIB
INET-ADDRESS-MIB DISMAN-PING-MIB IEEE8021-CFM-MIB
OSPF-MIB ZYXEL-ES-SMI

Imported symbols

enterprises OBJECT-TYPE RowStatus
DateAndTime TruthValue StorageType
MacAddress DisplayString EnabledStatus
PortList dot1dBasePort InterfaceIndexOrZero
SnmpAdminString InetAddressType InetAddress
OperationResponseStatus Counter TimeTicks
BridgeId Timeout dot1agCfmMdIndex
dot1agCfmMaIndex dot1agCfmMepIdentifier IpAddress
ifIndex NOTIFICATION-TYPE sysObjectID
ospfIfIpAddress ospfAddressLessIf ospfAreaId
ospfNbrIpAddr ospfNbrAddressLessIndex ospfLsdbAreaId
ospfLsdbType ospfLsdbLsid ospfLsdbRouterId
ospfVirtIfAreaId ospfVirtIfNeighbor esMgmt

Defined Types

ZyxelSflowCollectorEntry  
SEQUENCE    
  zySflowCollectorIpAddressType InetAddressType
  zySflowCollectorIpAddress InetAddress
  zySflowCollectorUdpPort INTEGER
  zySflowCollectorRowStatus RowStatus

ZyxelSflowPortEntry  
SEQUENCE    
  zySflowPortState EnabledStatus

ZyxelSflowPortCollectorEntry  
SEQUENCE    
  zySflowPortCollectorIpAddressType InetAddressType
  zySflowPortCollectorIpAddress InetAddress
  zySflowPortCollectorSampleRate INTEGER
  zySflowPortCollectorPollInterval INTEGER
  zySflowPortCollectorRowStatus RowStatus

Defined Values

zyxelSflow 1.3.6.1.4.1.890.1.15.3.75
The subtree for sFlow
MODULE-IDENTITY    

zyxelSflowSetup 1.3.6.1.4.1.890.1.15.3.75.1
OBJECT IDENTIFIER    

zySflowState 1.3.6.1.4.1.890.1.15.3.75.1.1
Enable/Disable sflow on the switch. sFlow (RFC 3176) is a standard technology for monitoring switched networks. An sFlow agent embedded on a switch or router gets sample data and packet statistics from traffic forwarded through its ports. The sFlow agent then creates sFlow data and sends it to an sFlow collector. The sFlow collector is a server that collects and analyzes sFlow datagram. An sFlow datagram includes packet header, input and output interface, sampling process parameters and forwarding information. sFlow minimizes impact on CPU load of the switch as it analyzes sample data only. sFlow can continuously monitor network traffic and create reports for network performance analysis and troubleshooting. For example, you can use it to know which IP address or which type of traffic caused network congestion.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

zySflowMaxNumberOfCollectors 1.3.6.1.4.1.890.1.15.3.75.1.2
The maximum number of sFlow collectors entries that can be created.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

zyxelSflowCollectorTable 1.3.6.1.4.1.890.1.15.3.75.1.3
The table contains sFlow collector configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZyxelSflowCollectorEntry

zyxelSflowCollectorEntry 1.3.6.1.4.1.890.1.15.3.75.1.3.1
An entry contains sFlow collector configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZyxelSflowCollectorEntry  

zySflowCollectorIpAddressType 1.3.6.1.4.1.890.1.15.3.75.1.3.1.1
The Type of IP address for sflow collector entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddressType  

zySflowCollectorIpAddress 1.3.6.1.4.1.890.1.15.3.75.1.3.1.2
The IP address of the sFlow collector.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddress  

zySflowCollectorUdpPort 1.3.6.1.4.1.890.1.15.3.75.1.3.1.3
Enter a UDP port number the Switch uses to send sFlow datagram to the collector. If you change the port here, make sure you change it on the collector, too. The default port is 6343.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

zySflowCollectorRowStatus 1.3.6.1.4.1.890.1.15.3.75.1.3.1.4
This object allow entry to be create and deleted a sFlow collector entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zyxelSflowPortTable 1.3.6.1.4.1.890.1.15.3.75.1.4
The table contains sFlow port configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZyxelSflowPortEntry

zyxelSflowPortEntry 1.3.6.1.4.1.890.1.15.3.75.1.4.1
An entry contains sFlow port configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZyxelSflowPortEntry  

zySflowPortState 1.3.6.1.4.1.890.1.15.3.75.1.4.1.1
Enable/Disable sflow on the port.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

zySflowMaxNumberOfPortCollectors 1.3.6.1.4.1.890.1.15.3.75.1.5
The maximum number of sFlow port collectors entries that can be created.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

zyxelSflowPortCollectorTable 1.3.6.1.4.1.890.1.15.3.75.1.6
The table contains sFlow port collector configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZyxelSflowPortCollectorEntry

zyxelSflowPortCollectorEntry 1.3.6.1.4.1.890.1.15.3.75.1.6.1
An entry contains sFlow port collector configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZyxelSflowPortCollectorEntry  

zySflowPortCollectorIpAddressType 1.3.6.1.4.1.890.1.15.3.75.1.6.1.1
The Type of IP address for sflow port collector entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddressType  

zySflowPortCollectorIpAddress 1.3.6.1.4.1.890.1.15.3.75.1.6.1.2
The IP address of the sFlow port collector.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddress  

zySflowPortCollectorSampleRate 1.3.6.1.4.1.890.1.15.3.75.1.6.1.3
Enter a number (N) from 256 to 65535. The switch captures every one out of N packets for this port and creates sFlow datagram.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

zySflowPortCollectorPollInterval 1.3.6.1.4.1.890.1.15.3.75.1.6.1.4
Specify a time interval (from 20 to 120 in seconds) the switch waits before sending the sFlow datagram and packet counters for this port to the collector.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

zySflowPortCollectorRowStatus 1.3.6.1.4.1.890.1.15.3.75.1.6.1.5
This object allows a sFlow port collector entry to be created and deleted.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus