ZYXEL-PPPoE-MIB
File:
ZYXEL-PPPoE-MIB.mib (13331 bytes)
Imported modules
Imported symbols
Defined Types
ZyxelPppoeIaPortEntry |
|
SEQUENCE |
|
|
|
|
zyPppoeIaPortTrustState |
EnabledStatus |
|
|
zyPppoeIaPortCircuitIdString |
DisplayString |
|
|
zyPppoeIaPortRemoteIdString |
DisplayString |
|
ZyxelPppoeIaVlanEntry |
|
SEQUENCE |
|
|
|
|
zyPppoeIaVlanVid |
INTEGER |
|
|
zyPppoeIaVlanCircuitIdState |
EnabledStatus |
|
|
zyPppoeIaVlanRemoteIdState |
EnabledStatus |
|
|
zyPppoeIaVlanRowStatus |
RowStatus |
|
ZyxelPppoeIaPortVlanEntry |
|
SEQUENCE |
|
|
|
|
zyPppoeIaPortVlanVid |
INTEGER |
|
|
zyPppoeIaPortVlanCircuitIdString |
DisplayString |
|
|
zyPppoeIaPortVlanRemoteIdString |
DisplayString |
|
|
zyPppoeIaPortVlanRowStatus |
RowStatus |
|
Defined Values
zyxelPppoe |
1.3.6.1.4.1.890.1.15.3.67 |
The subtree for Point-to-Point Protocol over Ethernet (PPPoE) |
MODULE-IDENTITY |
|
|
|
zyPppoeIaState |
1.3.6.1.4.1.890.1.15.3.67.1.1 |
Enable/Disable PPPoE intermediate agent globally on the switch. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
EnabledStatus |
|
|
zyPppoeIaAccessNodeIdString |
1.3.6.1.4.1.890.1.15.3.67.1.2 |
Up to 20 alphanumeric characters to identify the PPPoE intermediate agent.
Hyphens and spaces are also allowed. The default is the switch's host name. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
zyPppoeIaFlexibleCircuitIdSyntaxState |
1.3.6.1.4.1.890.1.15.3.67.1.3 |
Enable/Disable this if you want the switch to add the user-defined identifier string and
variables to PADI and PADR packets from PPPoE clients. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
EnabledStatus |
|
|
zyPppoeIaFlexibleCircuitIdSyntaxOption |
1.3.6.1.4.1.890.1.15.3.67.1.5 |
Select the variables that you want the switch to generate and add in the agnet circuit
ID sub-option. The variable options include sp, sv,pv and spv which indicate combinations
of slot-port, slot-VLAN, port-VLAN and slot-port-VLAN respectively. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
sp(1), sv(2), pv(3), spv(4) |
|
zyPppoeIaFlexibleCircuitIdSyntaxDelimiter |
1.3.6.1.4.1.890.1.15.3.67.1.6 |
Select a delimiter to spearate the identifier-string, slot ID, port number and/or VLAN ID from each other. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
pound-sign(1), dot(2), comma(3), semicolon(4), slash(5), space(6) |
|
zyxelPppoeIaPortTable |
1.3.6.1.4.1.890.1.15.3.67.1.7 |
The table contains PPPoE intermediate agent on the specified port configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
ZyxelPppoeIaPortEntry |
|
zyxelPppoeIaPortEntry |
1.3.6.1.4.1.890.1.15.3.67.1.7.1 |
An entry contains PPPoE intermediate agent on the specified port configuration |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZyxelPppoeIaPortEntry |
|
|
zyPppoeIaPortTrustState |
1.3.6.1.4.1.890.1.15.3.67.1.7.1.1 |
Enable/Disable trusted port on the specified port.
Trusted ports are uplink ports connected to PPPoE servers.
If a PADO (PPPoE Active Discovery Offer), PADS (PPPoE Active Discovery Session-confirmation), or PADT (PPPoE Active Discovery Terminate) packet is sent from a PPPoE server and received on a trusted port, the Switch forwards it to all other ports.
If a PADI or PADR packet is sent from a PPPoE client but received on a trusted port, the Switch forwards it to other trusted port(s).
Untrusted ports are downlink ports connected to subscribers.
If a PADI, PADR, or PADT packet is sent from a PPPoE client and received on an untrusted port, the Switch adds a vendor-specific tag to the packet and then forwards it to the trusted port(s).
The Switch discards PADO and PADS packets which are sent from a PPPoE server but received on an untrusted port. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
EnabledStatus |
|
|
zyPppoeIaPortCircuitIdString |
1.3.6.1.4.1.890.1.15.3.67.1.7.1.2 |
Enter a string of up to 63 ASCII characters that the switch adds into the Agent Circuit ID
sub-option for PPPoE discovery packets received on this port. Spaces are allowed. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
zyPppoeIaPortRemoteIdString |
1.3.6.1.4.1.890.1.15.3.67.1.7.1.3 |
Enter a string of up to 63 ASCII characters that the switch adds into the Agent Remote ID sub-option
for PPPoE discovery packets received on this port. Space are allows. If you do not specify a string
here or in the Remote-id field for a VLAN on a port, the Switch automatically uses the PPPoE clients
MAC address. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
zyPppoeIaMaxNumberOfVlans |
1.3.6.1.4.1.890.1.15.3.67.1.8 |
The maximum number of PPPoE IA vlan entries that can be created. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
zyxelPppoeIaVlanTable |
1.3.6.1.4.1.890.1.15.3.67.1.9 |
The table contains PPPoE intermediate agent for the specified VLAN configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
ZyxelPppoeIaVlanEntry |
|
zyxelPppoeIaVlanEntry |
1.3.6.1.4.1.890.1.15.3.67.1.9.1 |
An entry contains PPPoE intermediate agent for the specified VLAN configuration. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZyxelPppoeIaVlanEntry |
|
|
zyPppoeIaVlanVid |
1.3.6.1.4.1.890.1.15.3.67.1.9.1.1 |
VLAN ID you want to configure. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..4094 |
|
zyPppoeIaVlanRowStatus |
1.3.6.1.4.1.890.1.15.3.67.1.9.1.4 |
This object allows entries to be created and deleted from the PPPoE IA VLAN table. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
zyPppoeIaMaxNumberOfPortVlans |
1.3.6.1.4.1.890.1.15.3.67.1.10 |
The maximum number of PPPoE IA per port per vlan entries that can be created. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
zyxelPppoeIaPortVlanEntry |
1.3.6.1.4.1.890.1.15.3.67.1.11.1 |
An entry contains PPPoE intermediate agent for the specified VLAN on the specified port configuration |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
ZyxelPppoeIaPortVlanEntry |
|
|
zyPppoeIaPortVlanVid |
1.3.6.1.4.1.890.1.15.3.67.1.11.1.1 |
VLAN ID you want to configure. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
zyPppoeIaPortVlanCircuitIdString |
1.3.6.1.4.1.890.1.15.3.67.1.11.1.2 |
A string of up to 63 ASCII characters that the switch adds into the agent circuit ID sub-option for
PPPoE discovery packets received on this VLAN on the specified port. The circuit ID you configure for
a specific VLAN on a port has the highest priority. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
zyPppoeIaPortVlanRemoteIdString |
1.3.6.1.4.1.890.1.15.3.67.1.11.1.3 |
A string of up to 63 ASCII characters that the switch adds into the agent remote ID sub-option for
PPPoE discovery packets received on this VLAN on the specified port. If you do not specify a string
here or in the Remote-id field for a specific port, the Switch automatically uses the PPPoE clients
MAC address. The remote ID you configure for a specific VLAN on a port has the highest priority. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
zyPppoeIaPortVlanRowStatus |
1.3.6.1.4.1.890.1.15.3.67.1.11.1.4 |
This object allows entries to be created and deleted from the PPPoE IA port VLAN table. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|