ZTE-AN-QOS-TRAFFIC-MIB

File: ZTE-AN-QOS-TRAFFIC-MIB.mib (35602 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI SNMPv2-CONF
ZTE-AN-SMI IF-MIB ZTE-AN-IF-MIB

Imported symbols

RowStatus DisplayString Counter64
MODULE-IDENTITY OBJECT-TYPE Integer32
OBJECT-GROUP MODULE-COMPLIANCE zxAnQos
ifIndex zxAnSubIfIndex

Defined Types

ZxAnQosTrafficPrfEntry  
SEQUENCE    
  zxAnQosTrafficPrfName DisplayString
  zxAnQosTrafficPrfCir INTEGER
  zxAnQosTrafficPrfCbs INTEGER
  zxAnQosTrafficPrfPir INTEGER
  zxAnQosTrafficPrfPbs INTEGER
  zxAnQosTrafficPrfDiscardMode INTEGER
  zxAnQosTrafficPrfColorMode INTEGER
  zxAnQosTrafficPrfPolicerType INTEGER
  zxAnQosTrafficPrfCouplingEn INTEGER
  zxAnQosTrafficPrfRowStatus RowStatus

ZxAnQosTrafficIfConfEntry  
SEQUENCE    
  zxAnQosTrafficIfDirection INTEGER
  zxAnQosTrafficIfConfPrf DisplayString
  zxAnQosTrafficIfRowStatus RowStatus

ZxAnQosTrafficIfQueueConfEntry  
SEQUENCE    
  zxAnQosTrafficIfQueueId Integer32
  zxAnQosTrafficIfQueueDirection INTEGER
  zxAnQosTrafficIfQueueConfPrf DisplayString
  zxAnQosTrafficIfQueueRowStatus RowStatus

ZxAnQosTrafficIfShape2ConfEntry  
SEQUENCE    
  zxAnQosTrafficIfShape2Direction INTEGER
  zxAnQosTrafficIfShape2ConfPrf DisplayString
  zxAnQosTrafficIfShape2RowStatus RowStatus

ZxAnQosTrafficFlowPrfEntry  
SEQUENCE    
  zxAnQosTrafficFlowPrfName DisplayString
  zxAnQosTrafficFlowPrfMode INTEGER
  zxAnQosTrafficFlowPrfRowStatus RowStatus

ZxAnQosTrafficFlowRulePrfEntry  
SEQUENCE    
  zxAnQosTrafficFlowRuleId Integer32
  zxAnQosTrafficFlowRuleCosList OCTET STRING
  zxAnQosTrafficFlowRuleTrafficPrf DisplayString
  zxAnQosTrafficFlowRuleCarThresh INTEGER
  zxAnQosTrafficFlowRuleRowStatus RowStatus

ZxAnQosTrafficFlowIfGrpConfEntry  
SEQUENCE    
  zxAnQosTrafficFlowIfGrpId Integer32
  zxAnQosTrafficFlowIfGrpDirection INTEGER
  zxAnQosTrafficFlowIfGrpFlowPrf DisplayString
  zxAnQosTrafficFlowIfGrpSvlanList OCTET STRING
  zxAnQosTrafficFlowIfGrpCvlanList OCTET STRING
  zxAnQosTrafficFlowIfGrpTrffcPrf DisplayString
  zxAnQosTrafficFlowIfGrpMode INTEGER
  zxAnQosTrafficFlowIfGrpRowStatus RowStatus

Defined Values

zxAnQosTrafficMib 1.3.6.1.4.1.3902.1082.50.2
This MIB defines ZTE Access Node QoS Traffic managed objects.
MODULE-IDENTITY    

zxAnQosTrafficGlobalObjects 1.3.6.1.4.1.3902.1082.50.2.1
OBJECT IDENTIFIER    

zxAnQosTrafficObjects 1.3.6.1.4.1.3902.1082.50.2.2
OBJECT IDENTIFIER    

zxAnQosTrafficCapabilities 1.3.6.1.4.1.3902.1082.50.2.1.1
The QoS traffic compatibility. The bit value 1 means the function represented by this bit is supported by this equipment. bit 0: value 1 means not supporting zxAnQosTrafficPrfDiscardMode and zxAnQosTrafficPrfColorMode in zxAnQosTrafficPrfTable. bit 1: value 1 means supporting zxAnQosTrafficIfShapingConfTable. bit 2: value 1 means supporting zxAnQosTrafficPrfColorMode in zxAnQosTrafficPrfTable, regardless of notSupportDiscardAndColorMode. bit 3: value 1 means supporting zxAnQosTrafficPrfPolicerType and zxAnQosTrafficPrfCouplingEn in zxAnQosTrafficPrfTable. bit 4: value 1 means supporting zxAnQosTrafficIfShape2ConfTable. NOTE: No recommended to display it in NMS.
Status: current Access: read-only
OBJECT-TYPE    
  BITS notSupportDiscardAndColorMode(0), supportTrafficIfShapingConfTable(1), supportColorMode(2), supportPolicerTypeAndCouplingEn(3), supportTrafficIfShape2ConfTable(4)  

zxAnQosTrafficPrfTable 1.3.6.1.4.1.3902.1082.50.2.2.1
This table contains information about traffic controlling. An entry in this table reflects a profile defined which can be used to configure an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficPrfEntry

zxAnQosTrafficPrfEntry 1.3.6.1.4.1.3902.1082.50.2.2.1.1
zxAnQosTrafficPrfTable entry. The multi-variables binding rule should be complied with when a manager creates an entry. According to this rule, all the related mib variables must be included in one SNMP set operation. There are two types of variables: mandatory and optional. All of the mandatory variables must be included in one SNMP set operation. Optional variables may be included in one SNMP set operation with the mandatory variables, but must not be used alone. To create an entry, the mandatory and optional variables are as follows: mandatory: zxAnQosTrafficPrfCir, zxAnQosTrafficPrfCbs, zxAnQosTrafficPrfPir, zxAnQosTrafficPrfPbs, zxAnQosTrafficPrfDiscardMode, zxAnQosTrafficPrfColorMode, zxAnQosTrafficPrfPolicerType, zxAnQosTrafficPrfCouplingEn, zxAnQosTrafficPrfRowStatus. optional : none. To delete an entry, only zxAnQosTrafficPrfRowStatus is needed in one SNMP setOperation. After an entry is created, variables zxAnQosTrafficPrfCir, zxAnQosTrafficPrfCbs, zxAnQosTrafficPrfPir, zxAnQosTrafficPrfPbs, zxAnQosTrafficPrfDiscardMode, zxAnQosTrafficPrfColorMode, zxAnQosTrafficPrfPolicerType and zxAnQosTrafficPrfCouplingEn can be modified alone. Make sure that zxAnQosTrafficPrfPir is not less than zxAnQosTrafficPrfCir, and zxAnQosTrafficPrfPbs is not less than zxAnQosTrafficPrfCbs when to create or modify an entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficPrfEntry  

zxAnQosTrafficPrfName 1.3.6.1.4.1.3902.1082.50.2.2.1.1.1
Traffic profile name which can be applied to an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficPrfCir 1.3.6.1.4.1.3902.1082.50.2.2.1.1.2
Committed Information Rate(CIR) in kbps.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000000  

zxAnQosTrafficPrfCbs 1.3.6.1.4.1.3902.1082.50.2.2.1.1.3
Committed Burst Size(CBS) in kbytes.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..131072  

zxAnQosTrafficPrfPir 1.3.6.1.4.1.3902.1082.50.2.2.1.1.4
Peak Information Rate(PIR) in kbps.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..10000000  

zxAnQosTrafficPrfPbs 1.3.6.1.4.1.3902.1082.50.2.2.1.1.5
Peak Burst Size(PBS) in kbyte.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..131072  

zxAnQosTrafficPrfDiscardMode 1.3.6.1.4.1.3902.1082.50.2.2.1.1.6
The discard mode is used when the traffic exceeds the limit. noDistinction(1) -- discard extra flow equally. lowPriorityFirst(2) -- discard low priority flow firstly.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER noDistinction(1), lowPriorityFirst(2)  

zxAnQosTrafficPrfColorMode 1.3.6.1.4.1.3902.1082.50.2.2.1.1.7
Color mode. aware(1) -- color aware mode. blind(2) -- color blind mode.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER aware(1), blind(2)  

zxAnQosTrafficPrfPolicerType 1.3.6.1.4.1.3902.1082.50.2.2.1.1.8
Policer type.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enhancedMef(1), mef(2), rfc(3), multipleThresholds(4)  

zxAnQosTrafficPrfCouplingEn 1.3.6.1.4.1.3902.1082.50.2.2.1.1.9
Enables or disables the coupling enabling.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnQosTrafficPrfRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.1.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficPrfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficIfConfTable 1.3.6.1.4.1.3902.1082.50.2.2.2
This table contains interface's traffic configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficIfConfEntry

zxAnQosTrafficIfConfEntry 1.3.6.1.4.1.3902.1082.50.2.2.2.1
This table contains QoS traffic configuration parameters for gpon olt interface and gpon onu interface. There are two types of variables: mandatory and optional. All of the mandatory variables must be included in one SNMP set operation. Optional variables may be included in one SNMP set operation with the mandatory variables, but must not be used alone. To create an entry, the mandatory and optional variables are different for certain interface. For gpon olt interface, the mandatory and optional variables are as follows: mandatory: zxAnQosTrafficIfConfPrf, zxAnQosTrafficIfRowStatus optional : none. For gpon onu interface, the mandatory and optional variables are as follows: mandatory: zxAnQosTrafficIfConfPrf, zxAnQosTrafficIfRowStatus To delete an entry, only zxAnQosTrafficPrfRowStatus is needed in one SNMP setOperation. After an entry is created, certain variable can be modified. For gpon olt interface, only variable zxAnQosTrafficIfConfPrf can be modified. If a manager tries to modify any other variables in this entry, agent will return error with SNMP error code inconsistentValue.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficIfConfEntry  

zxAnQosTrafficIfDirection 1.3.6.1.4.1.3902.1082.50.2.2.2.1.1
Egress direction or ingress direction on an interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER ingress(1), egress(2)  

zxAnQosTrafficIfConfPrf 1.3.6.1.4.1.3902.1082.50.2.2.2.1.2
This object configures traffic profile of ingress or egress direction. The value of this object is the name of the referenced profile in the zxAnQosTrafficPrfTable.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficIfRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.2.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficIfConfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficIfQueueConfTable 1.3.6.1.4.1.3902.1082.50.2.2.4
Traffic configuration based on the queue of the interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficIfQueueConfEntry

zxAnQosTrafficIfQueueConfEntry 1.3.6.1.4.1.3902.1082.50.2.2.4.1
Traffic configuration based on the queue of the interface entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficIfQueueConfEntry  

zxAnQosTrafficIfQueueId 1.3.6.1.4.1.3902.1082.50.2.2.4.1.1
Queue ID. The number of queues is fixed to zxAnQosGlobalMaxQueues in ZTE-AN-QOS-MIB.mib.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 0..7  

zxAnQosTrafficIfQueueDirection 1.3.6.1.4.1.3902.1082.50.2.2.4.1.2
The direction of the queue.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER egress(1), ingress(2)  

zxAnQosTrafficIfQueueConfPrf 1.3.6.1.4.1.3902.1082.50.2.2.4.1.3
Traffic configuration profile. The value of this object is the name of the referenced profile in the zxAnQosTrafficPrfTable.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficIfQueueRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.4.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficIfQueueConfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficIfShape2ConfTable 1.3.6.1.4.1.3902.1082.50.2.2.6
Egress or ingress traffic shaping configuration based on the interface table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficIfShape2ConfEntry

zxAnQosTrafficIfShape2ConfEntry 1.3.6.1.4.1.3902.1082.50.2.2.6.1
Egress or ingress traffic shaping configuration based on the interface entry. This table contains QoS traffic configuration parameters for physical interfaces (including ethernet interfaces and GPON OLT interfaces) and GPON ONU interfaces.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficIfShape2ConfEntry  

zxAnQosTrafficIfShape2Direction 1.3.6.1.4.1.3902.1082.50.2.2.6.1.1
The direction of the interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER egress(1), ingress(2)  

zxAnQosTrafficIfShape2ConfPrf 1.3.6.1.4.1.3902.1082.50.2.2.6.1.2
Traffic configuration profile. The value of this object is the name of the referenced profile in the zxAnQosTrafficPrfTable.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficIfShape2RowStatus 1.3.6.1.4.1.3902.1082.50.2.2.6.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficIfShapingConfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficFlowObjects 1.3.6.1.4.1.3902.1082.50.2.2.20
OBJECT IDENTIFIER    

zxAnQosTrafficFlowPrfTable 1.3.6.1.4.1.3902.1082.50.2.2.20.2
Traffic flow profile table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficFlowPrfEntry

zxAnQosTrafficFlowPrfEntry 1.3.6.1.4.1.3902.1082.50.2.2.20.2.1
Traffic flow profile entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficFlowPrfEntry  

zxAnQosTrafficFlowPrfName 1.3.6.1.4.1.3902.1082.50.2.2.20.2.1.1
Traffic flow profile name.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficFlowPrfMode 1.3.6.1.4.1.3902.1082.50.2.2.20.2.1.2
Traffic flow profile mode. cos(1): Rate is limited with CoS. any(2): Rate is limited without CoS.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER cos(1), any(2)  

zxAnQosTrafficFlowPrfRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.20.2.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficFlowPrfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficFlowRulePrfTable 1.3.6.1.4.1.3902.1082.50.2.2.20.3
Traffic flow rule of the profile table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficFlowRulePrfEntry

zxAnQosTrafficFlowRulePrfEntry 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1
Traffic flow rule of the profile entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficFlowRulePrfEntry  

zxAnQosTrafficFlowRuleId 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1.1
Flow rule ID of the profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..4  

zxAnQosTrafficFlowRuleCosList 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1.2
CoS list. | bit 0 | bit 1 | ... bit 7 | +----------+----------+----...-----------+ | CoS 0 | CoS 1 | ... CoS 7 | +----------+----------+----...-----------+ If one bit is set to '1', the corresponding CoS is configured to CoS list. If zxAnQosTrafficFlowPrfMode is any, this parameter must be all zero. If zxAnQosTrafficFlowPrfMode is cos, this parameter must be configured. A cos value can be set only once in the same profile.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(1)  

zxAnQosTrafficFlowRuleTrafficPrf 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1.3
Traffic configuration profile. The value of this object is the name of the referenced profile in the zxAnQosTrafficPrfTable. An empty string means not configured.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..32)  

zxAnQosTrafficFlowRuleCarThresh 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1.4
CAR (Commit Access Rate) threshold. The flow can take x% of the tokens from the token bucket at most. When the number of the tokens taken from the token bucket exceeds x%, the flow is forbidden to take any tokens. For example, percent100 means the flow can take tokens once the token buket is not empty.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER percent10(1), percent25(2), percent50(3), percent75(4), percent100(5)  

zxAnQosTrafficFlowRuleRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.20.3.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in ZxAnQosTrafficFlowRulePrfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficFlowIfGrpConfTable 1.3.6.1.4.1.3902.1082.50.2.2.20.4
Traffic flow interface group configuration information table for ethernet interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnQosTrafficFlowIfGrpConfEntry

zxAnQosTrafficFlowIfGrpConfEntry 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1
Traffic flow interface group configuration information entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnQosTrafficFlowIfGrpConfEntry  

zxAnQosTrafficFlowIfGrpId 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.1
Traffic flow group ID.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..15000  

zxAnQosTrafficFlowIfGrpDirection 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.2
Traffic flow direction.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER ingress(1), egress(2)  

zxAnQosTrafficFlowIfGrpFlowPrf 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.3
Traffic flow configuration profile. The value of this object is the name of the referenced profile in the zxAnQosTrafficFlowPrfTable.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..32)  

zxAnQosTrafficFlowIfGrpSvlanList 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.4
Traffic flow SVLAN list. The OCTET STRING contains pairs of values in the following structure: Octets 0-1 -- VLAN ID. Octets 2-3 -- VLAN ID. ... Octets 6-7 -- VLAN ID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnQosTrafficFlowIfGrpCvlanList 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.5
Traffic flow CVLAN list. The OCTET STRING contains pairs of values in the following structure: Octets 0-1 -- VLAN ID. Octets 2-3 -- VLAN ID. ... Octets 6-7 -- VLAN ID.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnQosTrafficFlowIfGrpTrffcPrf 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.6
Traffic configuration profile. The value of this object is the name of the referenced profile in the zxAnQosTrafficPrfTable. An empty string means not configured.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..32)  

zxAnQosTrafficFlowIfGrpMode 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.7
Traffic flow group mode. fullMatch(1): A SVLAN+CVLAN+CoSs is mapping to a rule. oneToOne(2): A SVLAN+CVLAN is mapping to a rule.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER fullMatch(1), oneToOne(2)  

zxAnQosTrafficFlowIfGrpRowStatus 1.3.6.1.4.1.3902.1082.50.2.2.20.4.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4), and must comply with the multi-variables binding rule described in zxAnQosTrafficFlowIfGrpConfEntry. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnQosTrafficConformance 1.3.6.1.4.1.3902.1082.50.2.4
OBJECT IDENTIFIER    

zxAnQosTrafficCompliances 1.3.6.1.4.1.3902.1082.50.2.4.1
OBJECT IDENTIFIER    

zxAnQosTrafficGroups 1.3.6.1.4.1.3902.1082.50.2.4.2
OBJECT IDENTIFIER    

zxAnQosTrafficCompliance 1.3.6.1.4.1.3902.1082.50.2.4.1.1
The compliance statement for entities which implement the ZTE-AN-QOS-TRAFFIC-MIB.
Status: current Access: read-create
MODULE-COMPLIANCE    

zxAnQosTrafficPrfGroup 1.3.6.1.4.1.3902.1082.50.2.4.2.1
A collection of objects creating, modifying or deleting a trafficPrf.
Status: current Access: read-create
OBJECT-GROUP    

zxAnQosTrafficIfConfGroup 1.3.6.1.4.1.3902.1082.50.2.4.2.2
A collection of objects configuring a trafficprf for an interface. For gpon olt and gpon onu interface, variable zxAnQosTrafficIfConfPrf and zxAnQosTrafficIfRowStatus can be configured.
Status: current Access: read-create
OBJECT-GROUP    

zxAnQosTrafficIfStatsGroup 1.3.6.1.4.1.3902.1082.50.2.4.2.3
A collection of total CIR for an interface.
Status: current Access: read-create
OBJECT-GROUP