ZTE-AN-PON-BASE-MIB

File: ZTE-AN-PON-BASE-MIB.mib (51700 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB ZTE-AN-SMI ZTE-AN-IF-MIB
INET-ADDRESS-MIB ZTE-AN-PON-TC-MIB

Imported symbols

enterprises RowStatus IpAddress
Unsigned32 Counter64 MacAddress
TEXTUAL-CONVENTION MODULE-IDENTITY OBJECT-GROUP
MODULE-COMPLIANCE OBJECT-TYPE NOTIFICATION-TYPE
ifIndex InterfaceIndex DisplayString
Integer32 zxAnPon zxAnSubIfIndex
NOTIFICATION-GROUP InetAddress InetAddressType
InetAddressPrefixLength ZxAnPonOnuIndex DateAndTime

Defined Types

ZxAnPonOnuTypeEntry  
SEQUENCE    
  zxAnPonOnuTypeName DisplayString
  zxAnPonOnuTypePonType INTEGER
  zxAnPonOnuTypeDesc DisplayString
  zxAnPonOnuTypeAttr1 Integer32
  zxAnPonOnuTypeAttr2 Integer32
  zxAnPonOnuTypeAttr3 Integer32
  zxAnPonOnuTypeAttr4 Integer32
  zxAnPonOnuTypeAttr5 Integer32
  zxAnPonOnuTypeAttr6 Integer32
  zxAnPonOnuTypeAttr7 Integer32
  zxAnPonOnuTypeAttr8 Integer32
  zxAnPonOnuTypeAttr9 Integer32
  zxAnPonOnuTypeAttr10 Integer32
  zxAnPonOnuTypeRowStatus RowStatus

ZxAnPonOnuIfAttrEntry  
SEQUENCE    
  zxAnPonOnuIfId Integer32
  zxAnPonOnuIfAttr1 Integer32
  zxAnPonOnuIfAttr2 Integer32
  zxAnPonOnuIfAttr3 Integer32
  zxAnPonOnuIfAttr4 Integer32
  zxAnPonOnuIfAttr5 Integer32
  zxAnPonOnuIfAttr6 Integer32
  zxAnPonOnuIfAttr7 Integer32
  zxAnPonOnuIfAttr8 Integer32
  zxAnPonOnuIfAttr9 Integer32
  zxAnPonOnuIfAttr10 Integer32
  zxAnPonOnuIfAttrRowStatus RowStatus

ZxAnPonRxOpticalPowerEntry  
SEQUENCE    
  zxAnPonOnuIndex ZxAnPonOnuIndex
  zxAnPonRxOpticalPower Integer32

ZxAnPonRxOpticalPowerThreshEntry  
SEQUENCE    
  zxAnPonRxPowerRisingAlarmThresh Integer32
  zxAnPonRxPowerFallingAlarmThresh Integer32
  zxAnPonRxPowerDetectPeriod Unsigned32
  zxAnPonRxPowerRestoreDefault INTEGER

ZxAnPonRogueOnuDetectInfoEntry  
SEQUENCE    
  zxAnRogueOnuSlot Integer32
  zxAnRogueOnuDetectEnable INTEGER
  zxAnRogueOnuLocatingEnable INTEGER
  zxAnRogueOnuAutoCloseEnable INTEGER

ZxAnPonRogueOnuInfoEntry  
SEQUENCE    
  zxAnPonRogueOnuInstIndex Integer32
  zxAnPonRogueOnuAuthStatus INTEGER
  zxAnPonRogueOnuId Integer32
  zxAnPonRogueOnuMacAddress MacAddress
  zxAnPonRogueOnuSerialNumber DisplayString
  zxAnPonRogueOnuDetectedTime DateAndTime

ZxAnPonPortRogueOnuConfEntry  
SEQUENCE    
  zxAnPortRogueOnuLocatingEnable INTEGER
  zxAnPortRogueOnuAutoCloseEnable INTEGER
  zxAnPortRogueOnuDetectEnable INTEGER

Defined Values

zxAnPonBaseMib 1.3.6.1.4.1.3902.1082.500.1
The MIB module for the management of PON.
MODULE-IDENTITY    

zxAnPonBaseObjects 1.3.6.1.4.1.3902.1082.500.1.2
OBJECT IDENTIFIER    

zxAnPonBaseNotifications 1.3.6.1.4.1.3902.1082.500.1.3
OBJECT IDENTIFIER    

zxAnPonOnuTypeObjects 1.3.6.1.4.1.3902.1082.500.1.2.2
OBJECT IDENTIFIER    

zxAnPonOamObjects 1.3.6.1.4.1.3902.1082.500.1.2.4
OBJECT IDENTIFIER    

zxAnPonGisObjects 1.3.6.1.4.1.3902.1082.500.1.2.5
OBJECT IDENTIFIER    

zxAnPonRogueOnuMgmt 1.3.6.1.4.1.3902.1082.500.1.2.4.1
OBJECT IDENTIFIER    

zxAnPonRogueOnuCtrl 1.3.6.1.4.1.3902.1082.500.1.2.4.1.1
OBJECT IDENTIFIER    

zxAnPonGisGlobalObjects 1.3.6.1.4.1.3902.1082.500.1.2.5.1
OBJECT IDENTIFIER    

zxAnPonOamTraps 1.3.6.1.4.1.3902.1082.500.1.3.1
OBJECT IDENTIFIER    

zxAnPonOnuTypeTable 1.3.6.1.4.1.3902.1082.500.1.2.2.2
Configuration of ONU type.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonOnuTypeEntry

zxAnPonOnuTypeEntry 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1
Entry of zxAnPonOnuTypeTable. For the default ONU type such as ZTE-F641,ZTE-F622, ZTE-F625, ZTE-F621, ZTE-F601, ZTE-F640, ZTE-F628, ZTE-9806, ZTE-D400, ZTE-D402, ZTE-D420, ZTE-D421, ZTE-D422, ZTE-F401, ZTE-F420, ZTE-F425, ZTE-F429, ZTE-F430, ZTE-F435, ZTE-F500, ZTE-F803, ZTE-F820, ZTE-F821, ZTE-F822, set operation is prohibited. The multi-variables binding rule should be complied with when a manager configures ONU type. According to this rule, all the related mib variables must be included in one SNMP set operation. There are two types of variables: mandatory and optional. All of the mandatory variables must be included in one SNMP set operation. Optional variables may be included in one SNMP set operation with the mandatory variables, but must not be used alone. To create or modify ONU type, the mandatory variables are as follows: mandatoty: zxAnPonOnuTypePonType.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonOnuTypeEntry  

zxAnPonOnuTypeName 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.1
Name of ONU type.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..64)  

zxAnPonOnuTypePonType 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.2
PON type.There are two types: -epon: Ethernet Passive Optical Network -gpon: Gigabit-Capable PON.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER epon(1), gpon(2)  

zxAnPonOnuTypeDesc 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.3
Description of ONU type. eg. the interface attributes of ONU type. This variable must comply with the multi-variables binding rule described in zxAnPonOnuTypeEntry.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..64)  

zxAnPonOnuTypeAttr1 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.4
For EPON: This attribute indicates protect type, 1-none, 2-typeC, 3-typeD, default value is 1. For GPON: This attribute indicates the maximum number of T-CONT, default value is 255. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr2 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.5
For EPON: This attribute indicates speed, 1-1G, 2-10G Symmetric, 3-10G Asymmetric, default value is 1. For GPON: This attribute indicates the maximum number of GEM port, default value is 255. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr3 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.6
For EPON: This attribute indicates ONU auto dispatch enable status, 1-enable, 2-disable, default value is 1. For GPON: This attribute indicates maximum number of switch per slot, default value is 255. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr4 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.7
For GPON: This attribute indicates maximum number of flow per switch, default value is 255. This attribute is not used for EPON. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr5 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.8
For GPON: This attribute indicates maximum number of IP host. MSB : Most Significant Byte LSB : Least Significant Byte | MSB | Byte 2 | Byte 1 | LSB | |--------------|--------------|-----------------|-----------------| | | |IPv6 host number | IPv4 host number| | (8bits) | (8bits) | (8bits) | (8bits) | |-----------------------------------------------------------------| IPv4 host default number is 2. IPv6 host default number is 0. This attribute is not used for EPON. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr6 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.9
For GPON: This attribute indicates service ability of ONU type, there are three service mode :N:1,1:M,1:P. If support the service mode,set the corresponding bit to 1, if not support, set to 0. Default value is 7. | MSB LSB| |-----|-----------|-----------|-----------| | ... | 1:P | 1:M | N:1 | | ... | (1bits) | (1bits) | (1bits) | +-----+-----------+-----------+-----------+ This attribute is not used for EPON. This variable must comply with the multi-variables binding rule described in 'zxAnPonOnuTypeEntry'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr7 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.10
The OLT OMCI management mode. | MSB | Byte 2 | Byte 1 | LSB | |-------------------------------------------------------------| | Reserved | Reserved | Reserved |Reserved WiFi | | (8bits) | (8bits) | (8bits) |(7bits) (1bit)| |-------------------------------------------------------------| Bits 1 - 31 are reserved for future use. Bit 0 represents WiFi service, default value is 0. If the bit is set to 1, WiFi service is managed via non-OMCI. If the bit is set to 0, WiFi service is managed via OMCI. This attribute is not used for EPON.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr8 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.11
A set of capabilities information about ONU. | MSB |Byte2|Byte1| LSB | |---------------------------------------------------------------------------| |Rese-|Rese-|Rese-|Rese-| GIS |Extended| | |Multicast| OMCI | |rved |rved |rved |rved |Function | OMCI | MGC | VRG | Address |Sending| |(8bi-|(8bi-|(8bi-|(1bi-| Enabling|Enabling| Mode | | Range | Mode | | ts) | ts) | ts) | ts)-|(1bit) | (1bit) |(2bits)|(1bit)| (1bit) |(1bit) | |----------------------- --------------------------------------------------| Bits 7 - 31 are reserved for future use. Bit 0 represents OMCI sending mode, default value is 0. If the bit is set to 1, OLT sends OMCI by synchronous mode. If the bit is set to 0, OLT sends OMCI by asynchronous mode. Bit 1 represents default multicast address range mode, default value is 0. If the bit is set to 1, default multicast address range is all-inclusive mode(224.0.0.0-239.255.255.255). If the bit is set to 0, default multicast address range is none. Bit 2 represents VRG enabling status, default value is 0. If the bit is set to 1, VRG function of the ONU is enabled. If the bit is set to 0, VRG function of the ONU is disabled. This attribute is not used for EPON. Bit 3 and bit 4 represent MGC configuration mode, default value is 0. If both of two bits are set to 0, the MGC configuration mode is private. If bit 3 is set to 1 and bit 4 is set to 0, the MGC configuration mode is ITU-T. If bit 3 is set to 0 and bit 4 is set to 1, the MGC configure mode is both. Bit 5 represents extended OMCI enabling status, default value is 0. If the bit is set to 1, extended OMCI is enabled. If the bit is set to 0, extended OMCI is disabled. This attribute is not used for EPON. Bit 6 represents PON GIS function is supported or not, default value is 0. If the bit is set to 1, GIS function is supported. If the bit is set to 0, GIS function is not supported.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr9 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.12
A set of capabilities information about ONU. | MSB | Byte 2 | Byte 1 | LSB | |-------------------------------------------------------------| | Reserved | Reserved | Reserved | VEIP Number | | (8bits) | (8bits) | (8bits) | (8bits) | |-------------------------------------------------------------| The LSB represents the number of VEIP port. The value 0 represents the system default. This attribute is not used for EPON.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeAttr10 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.13
A set of capabilities information about ONU. | MSB | Byte 2 | Byte 1 | LSB | |------------------------------------------------------------------| | Reserved | Reserved | Reserved |Reserved|Speed Mode| | (8bits) | (8bits) | (8bits) | (4bits)|(4bits) | |------------------------------------------------------------------| Bits 4 - 31 are reserved for future use. Bits 0 - 3 represents the ONU speed mode, 1 - GPON, 2 - XG-PON, 3 - XGS-PON, 4 - automatic, the default value is 4. This attribute is not used for EPON.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuTypeRowStatus 1.3.6.1.4.1.3902.1082.500.1.2.2.2.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4). In particular, a newly created row cannot be created until the corresponding zxAnPonOnuTypeName and zxAnPonOnuTypePonType have been set. To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnPonOnuIfAttrTable 1.3.6.1.4.1.3902.1082.500.1.2.2.3
Configuration of ONU interface attributes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonOnuIfAttrEntry

zxAnPonOnuIfAttrEntry 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1
Entry of zxAnPonOnuIfAttrTable. Entries in the zxAnPonOnuIfAttrTable are created and deleted using the zxAnPonOnuIfAttrRowStatus object, modify is prohibited.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonOnuIfAttrEntry  

zxAnPonOnuIfId 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.1
The most significant 16 bits indicate the type of this interface: ETH(10), E1(20), T1(21), DS1(22), POTS(30), RF(40), WiFi(50), COM(60), VEIP(70), xDSL(80). The least significant 16 bits indicate the ID of this interface: the first 8 bits specifies the slot ID associated with this UNI, the second 8 bits specifies the port ID associated with this UNI. eg.the zxAnPonOnuIfId for eth_0/1 is 655361(0xA0001).
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr1 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.2
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr2 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.3
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr3 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.4
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr4 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.5
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr5 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.6
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr6 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.7
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr7 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.8
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr8 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.9
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr9 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.10
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttr10 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.11
Reserved for future use.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnPonOnuIfAttrRowStatus 1.3.6.1.4.1.3902.1082.500.1.2.2.3.1.50
The status of this conceptual row. The supported actions of this conceptual row only include: 'createAndGo' and 'destroy'. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To get this object, the agent always returns active(1).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnPonRxOpticalPowerTable 1.3.6.1.4.1.3902.1082.500.1.2.4.2
Received optical power on OLT side from ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonRxOpticalPowerEntry

zxAnPonRxOpticalPowerEntry 1.3.6.1.4.1.3902.1082.500.1.2.4.2.1
Entry of zxAnPonRxOpticalPowerTable. The index 'zxAnPonOnuIndex' represents the normal ONU index.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonRxOpticalPowerEntry  

zxAnPonOnuIndex 1.3.6.1.4.1.3902.1082.500.1.2.4.2.1.1
This attribute represents the index of ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonOnuIndex  

zxAnPonRxOpticalPower 1.3.6.1.4.1.3902.1082.500.1.2.4.2.1.2
Measured the received optical power. 65535000 means N/A, ONU is not in service. -80000 means no signal received.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zxAnPonRxOpticalPowerThreshTable 1.3.6.1.4.1.3902.1082.500.1.2.4.4
Received threshold of transceiver on OLT side.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonRxOpticalPowerThreshEntry

zxAnPonRxOpticalPowerThreshEntry 1.3.6.1.4.1.3902.1082.500.1.2.4.4.1
Entry of zxAnPonRxOpticalPowerThreshTable. The index 'zxAnPonOnuIndex' represents the normal ONU index.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonRxOpticalPowerThreshEntry  

zxAnPonRxPowerRisingAlarmThresh 1.3.6.1.4.1.3902.1082.500.1.2.4.4.1.1
Rising alarm threshold of received power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -34000..-3000  

zxAnPonRxPowerFallingAlarmThresh 1.3.6.1.4.1.3902.1082.500.1.2.4.4.1.2
Falling alarm threshold of received power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -34000..-3000  

zxAnPonRxPowerDetectPeriod 1.3.6.1.4.1.3902.1082.500.1.2.4.4.1.3
Detect period.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 60..4294967295  

zxAnPonRxPowerRestoreDefault 1.3.6.1.4.1.3902.1082.500.1.2.4.4.1.4
The action of the ONU, when do the action, the 'zxAnPonRxPowerRisingAlarmThresh' value and 'zxAnPonRxPowerFallingAlarmThresh' value will be restored to the system defaule value.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER restoreDefault(1)  

zxAnPonRogueOnuOltIndex 1.3.6.1.4.1.3902.1082.500.1.2.4.1.1.1
Same as ifIndex: |-------------+----------|------------|---------|---------| |InterfaceType| rack No. | Shelf No. | Slot No.| Port No.| | 1 (4bits) | (4bits) | (8bits) | (8bits) | (8bits) | +-------------+----------+------------+---------+---------+ The multi-variables binding rule should be complied with when a manager configures rogue ONU control. According to this rule, all the related mib variables must be included in one SNMP set operation. There are two types of variables: mandatory and optional. All of the mandatory variables must be included in one SNMP set operation. Optional variables may be included in one SNMP set operation with the mandatory variables, but must not be used alone. To configure rogue ONU control, the mandatory and optional variables are as follows: mandatoty: zxAnPonRogueOnuOltIndex, zxAnPonRogueOnuIndex
Status: current Access: read-write
OBJECT-TYPE    
  InterfaceIndex  

zxAnPonRogueOnuIndex 1.3.6.1.4.1.3902.1082.500.1.2.4.1.1.2
Represents the normal ONU index.
Status: current Access: read-write
OBJECT-TYPE    
  ZxAnPonOnuIndex  

zxAnPonRogueOnuState 1.3.6.1.4.1.3902.1082.500.1.2.4.1.1.3
This object indicates the control action. -rogueOn:open the transmit power. -rogueOff:close the transmit power. -shutDown:shutdown the transceiver.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER rogueOn(1), rogueOff(2), shutDown(3)  

zxAnPonRogueOnuRecoverTime 1.3.6.1.4.1.3902.1082.500.1.2.4.1.1.4
This object indicates the recovery time. When 'zxAnPonRogueOnuState' is 'rogueOn', 'zxAnPonRogueOnuRecoverTime' is invalid.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

zxAnPonRogueOnuDetectInfoTable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2
This table is defined to control rogue ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonRogueOnuDetectInfoEntry

zxAnPonRogueOnuDetectInfoEntry 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2.1
Entry of zxAnPonRogueOnuDetectInfoTable. The multi-variables binding rule should be complied with when a manager configures rogue ONU detect. According to this rule, all the related mib variables must be included in one SNMP set operation. There are two types of variables: mandatory and optional. All of the mandatory variables must be included in one SNMP set operation. Optional variables may be included in one SNMP set operation with the mandatory variables, but must not be used alone. To configure rogue ONU detect, the mandatory and optional variables are as follows: mandatoty: zxAnRogueOnuDetectEnable, zxAnRogueOnuLocatingEnable, zxAnRogueOnuAutoCloseEnable.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonRogueOnuDetectInfoEntry  

zxAnRogueOnuSlot 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2.1.1
The OLT slot to be configured rogue ONU detection.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

zxAnRogueOnuDetectEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2.1.2
This object indicates the rogue ONU detection mode. -enabled(1): enable the rogue ONU detection -disabled(2): disable the rogue ONU detection.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnRogueOnuLocatingEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2.1.3
This object indicates the rogue ONU locating mode. -enabled(1): locating the rogue ONU -disabled(1): not locating the rogue ONU. When 'zxAnRogueOnuDetectEnable' is 'enabled', you can configure 'zxAnRogueOnuLocatingEnable'. When 'zxAnRogueOnuDetectEnable' is 'disabled', you can not configure 'zxAnRogueOnuLocatingEnable'. This object is not supported for C600 serial.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnRogueOnuAutoCloseEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.2.1.4
This object indicates the rogue ONU shutdown mode. -enabled(1): shutdown the rogue ONU automatically -disabled(2): shutdown the rogue ONU manually When 'zxAnRogueOnuLocatingEnable' is 'enabled', you can configure 'zxAnRogueOnuAutoCloseEnable'. When 'zxAnRogueOnuLocatingEnable' is 'disabled', you can not configure 'zxAnRogueOnuAutoCloseEnable'. This object is not supported for C600 serial.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnPonRogueOnuInfoTable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3
This table is defined to get rogue ONU information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonRogueOnuInfoEntry

zxAnPonRogueOnuInfoEntry 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1
It is an entry in the zxAnPonRogueOnuInfoTable. The index 'ifIndex' represents the normal OLT index
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonRogueOnuInfoEntry  

zxAnPonRogueOnuInstIndex 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.1
The instance No. of the rogue ONU.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..256  

zxAnPonRogueOnuAuthStatus 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.2
The rogue ONU authentication status, 'authenticated' means this ONU is authenticated and 'unauthenticated' means this ONU is discovered by OLT but not authenticated.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER authenticated(1), unauthenticated(2)  

zxAnPonRogueOnuId 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.3
The unique ONU ID of the specified PON port, value 0 means ONU is discovered by OLT but not authenticated.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..256  

zxAnPonRogueOnuMacAddress 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.4
The MAC address of the rogue ONU, only for EPON ONU.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

zxAnPonRogueOnuSerialNumber 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.5
The SN of the rogue ONU, only for GPON ONU.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..12)  

zxAnPonRogueOnuDetectedTime 1.3.6.1.4.1.3902.1082.500.1.2.4.1.3.1.6
The date and time when the rogue ONU is detected.
Status: current Access: read-only
OBJECT-TYPE    
  DateAndTime  

zxAnPonPortRogueOnuConfTable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.4
The PON port rogue ONU management table. This table only is used for C600 serial.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPonPortRogueOnuConfEntry

zxAnPonPortRogueOnuConfEntry 1.3.6.1.4.1.3902.1082.500.1.2.4.1.4.1
The PON port rogue ONU management entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPonPortRogueOnuConfEntry  

zxAnPortRogueOnuLocatingEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.4.1.1
The rogue ONU locating mode. enabled(1): locating the rogue ONU disabled(2): not locating the rogue ONU.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnPortRogueOnuAutoCloseEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.4.1.2
The rogue ONU shutdown mode. enabled(1): shutdown the rogue ONU automatically disabled(2): shutdown the rogue ONU manually.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnPortRogueOnuDetectEnable 1.3.6.1.4.1.3902.1082.500.1.2.4.1.4.1.3
The rogue ONU detection mode. enabled(1) enable the rogue ONU detection function disabled(2): disable the rogue ONU detection function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnPonGisLongitude 1.3.6.1.4.1.3902.1082.500.1.2.5.1.1
The longitude of the PON equipment.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -18000000..18000000  

zxAnPonGisLatitude 1.3.6.1.4.1.3902.1082.500.1.2.5.1.2
The latitude of the PON equipment.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -9000000..9000000  

zxAnPonGisElevation 1.3.6.1.4.1.3902.1082.500.1.2.5.1.3
The elevation of the PON equipment.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -32768..32767  

zxAnPonGisHorizontalError 1.3.6.1.4.1.3902.1082.500.1.2.5.1.4
The horizontal error of the PON equipment. It caused by the changing of horizontal location during the measurement.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

zxAnPonGisAltitudeError 1.3.6.1.4.1.3902.1082.500.1.2.5.1.5
The altitude error of the PON equipment. It caused by the changing of altitude location during the measurement.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

zxAnPonGisAreaCode 1.3.6.1.4.1.3902.1082.500.1.2.5.1.6
The GIS area code of the PON equipment. It references from the latest version 2013 of NBS(National Bureau of Statistics of China), http://www.stats.gov.cn/tjsj/tjbz/tjyqhdmhcxhfdm/2013/index.html.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnPonGisTimestamp 1.3.6.1.4.1.3902.1082.500.1.2.5.1.7
The timestamp of GIS generated by BUAPP. The offset time based on 0 hour 0 minute 0 second Jan 1st 1970 in seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295  

zxAnPonGisDigest 1.3.6.1.4.1.3902.1082.500.1.2.5.1.8
The GIS digest.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnPonGisCheckCode 1.3.6.1.4.1.3902.1082.500.1.2.5.1.9
The GIS check code. In order to prevent user input wrong information, the OLT will generate a new check code according to the calculation of above 8 variables, and compare the new check code with the check code generated by BUAPP.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(2)  

zxAnPonRxPowerHighAlm 1.3.6.1.4.1.3902.1082.500.1.3.1.1
Alarm for received power.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnPonRxPowerHighClr 1.3.6.1.4.1.3902.1082.500.1.3.1.2
Restore of alarm for received power.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnPonRxPowerLowAlm 1.3.6.1.4.1.3902.1082.500.1.3.1.3
Alarm for received power.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnPonRxPowerLowClr 1.3.6.1.4.1.3902.1082.500.1.3.1.4
Restore of alarm for received power.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnPonBaseConformance 1.3.6.1.4.1.3902.1082.500.1.4
OBJECT IDENTIFIER    

zxAnPonCompliances 1.3.6.1.4.1.3902.1082.500.1.4.1
OBJECT IDENTIFIER    

zxAnPonGroups 1.3.6.1.4.1.3902.1082.500.1.4.2
OBJECT IDENTIFIER    

zxAnPonCompliance 1.3.6.1.4.1.3902.1082.500.1.4.1.1
The compliance statement for entities which implement the ZTE-AN-PON-BASE-MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

zxAnPonOnuTypeGroup 1.3.6.1.4.1.3902.1082.500.1.4.2.2
A collection of objects for ONU type configuration.
Status: current Access: read-write
OBJECT-GROUP    

zxAnPonOamGroup 1.3.6.1.4.1.3902.1082.500.1.4.2.4
A collection of objects for OLT diagnose.
Status: current Access: read-write
OBJECT-GROUP    

zxAnPonGisGroup 1.3.6.1.4.1.3902.1082.500.1.4.2.6
A collection of objects for ONU gis configuration data.
Status: current Access: read-write
OBJECT-GROUP    

zxAnPonTrapGroup 1.3.6.1.4.1.3902.1082.500.1.4.2.20
A collection of notifications.
Status: current Access: read-write
NOTIFICATION-GROUP