ZTE-AN-IEEE1588-MIB

File: ZTE-AN-IEEE1588-MIB.mib (91459 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC INET-ADDRESS-MIB
SNMPv2-CONF ZTE-AN-SMI ZTE-AN-TC-MIB
IF-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 RowStatus TruthValue
DisplayString MacAddress InetAddress
InetAddressType InetAddressPrefixLength OBJECT-GROUP
NOTIFICATION-TYPE MODULE-COMPLIANCE zxAnClockSync
VlanId ifIndex

Defined Types

ZxAnPtpIfConfEntry  
SEQUENCE    
  zxAnPtpIfConfClockId OCTET STRING
  zxAnPtpIfConfNumber Integer32
  zxAnPtpIfConfState INTEGER
  zxAnPtpIfConfMinDelayReqInterval INTEGER
  zxAnPtpIfConfAnnounceInterval Integer32
  zxAnPtpIfConfMaxLossAnnounceMsgs Integer32
  zxAnPtpIfConfSyncInterval INTEGER
  zxAnPtpIfConfLocalPriority Integer32
  zxAnPtpIfConfPtpMsgProtocolType INTEGER
  zxAnPtpIfConfAddressType INTEGER
  zxAnPtpIfConfMsgForwardOption INTEGER
  zxAnPtpIfConfDelayCompensation Integer32
  zxAnPtpIfConfAdminStatus INTEGER
  zxAnPtpIfConfRowStatus RowStatus

ZxAnPtpPrfEntry  
SEQUENCE    
  zxAnPtpPrfName DisplayString
  zxAnPtpPrfPriority2 Integer32
  zxAnPtpPrfDomainNumber Integer32
  zxAnPtpPrfLocalPriority Integer32
  zxAnPtpPrfMaxStepsRemoved Integer32
  zxAnPtpPrfBmcaOption INTEGER
  zxAnPtpPrfTraceOption INTEGER
  zxAnPtpPrfHoldoverInTimeout INTEGER
  zxAnPtpPrfRowStatus RowStatus

ZxAnPtpIfStatsEntry  
SEQUENCE    
  zxAnPtpIfStatsAnnounceMsgs Counter32
  zxAnPtpIfStatsSyncMsgs Counter32
  zxAnPtpIfStatsDelayReqMsgs Counter32
  zxAnPtpIfStatsDelayRespMsgs Counter32
  zxAnPtpIfStatsFollowUpMsgs Counter32

ZxAnSyncTime1ppsSrcEntry  
SEQUENCE    
  zxAnSyncTime1ppsSrcId Integer32
  zxAnSyncTime1ppsSrcRack Integer32
  zxAnSyncTime1ppsSrcShelf Integer32
  zxAnSyncTime1ppsSrcSlot Integer32
  zxAnSyncTime1ppsSrcFirstPtp TruthValue
  zxAnSyncTime1ppsSrcSignalType INTEGER
  zxAnSyncTime1ppsSrcPriority Integer32
  zxAnSyncTime1ppsSrcPortType INTEGER
  zxAnSyncTime1ppsSrcPort Integer32
  zxAnSyncTime1ppsSrcWorkStatus INTEGER
  zxAnSyncTime1ppsSrcValidStatus INTEGER
  zxAnSyncTime1ppsSrcPortStatus INTEGER
  zxAnSyncTime1ppsSrcFormat INTEGER
  zxAnSyncTime1ppsSrcCurrentQL INTEGER
  zxAnSyncTime1ppsSrcTimeAccuracy Integer32
  zxAnSyncTime1ppsSrcTimeSrcType INTEGER
  zxAnSyncTime1ppsSrcDlyCompensate Integer32
  zxAnSyncTime1ppsSrcRowStatus RowStatus

ZxAnSyncTimeTodSrcEntry  
SEQUENCE    
  zxAnSyncTimeTodSrcId Integer32
  zxAnSyncTimeTodSrcRack Integer32
  zxAnSyncTimeTodSrcShelf Integer32
  zxAnSyncTimeTodSrcSlot Integer32
  zxAnSyncTimeTodSrcPort Integer32
  zxAnSyncTimeTodSrcSignalType INTEGER
  zxAnSyncTimeTodSrcYearAdjust Integer32
  zxAnSyncTimeTodSrcPortStatus INTEGER
  zxAnSyncTimeTodSrcRowStatus RowStatus

ZxAnSyncTimeOutputPortEntry  
SEQUENCE    
  zxAnSyncTimeOutputId Integer32
  zxAnSyncTimeOutputRack Integer32
  zxAnSyncTimeOutputShelf Integer32
  zxAnSyncTimeOutputSlot Integer32
  zxAnSyncTimeOutputPort Integer32
  zxAnSyncTimeOutputPortEnable INTEGER
  zxAnSyncTimeOutputPortPhaseAdjus Integer32
  zxAnSyncTimeOutputPortRowStatus RowStatus

Defined Values

zxAnIeee1588Mib 1.3.6.1.4.1.3902.1082.120.15
The MIB module for the management of IEEE1588 .
MODULE-IDENTITY    

zxAnIeee1588GlobalObjects 1.3.6.1.4.1.3902.1082.120.15.1
OBJECT IDENTIFIER    

zxAnIeee1588Objects 1.3.6.1.4.1.3902.1082.120.15.2
OBJECT IDENTIFIER    

zxAnIeee1588Notifications 1.3.6.1.4.1.3902.1082.120.15.3
OBJECT IDENTIFIER    

zxAnIeee1588AlmThreshObjects 1.3.6.1.4.1.3902.1082.120.15.1.11
OBJECT IDENTIFIER    

zxAnIeee1588TimeStatusInfoObjs 1.3.6.1.4.1.3902.1082.120.15.1.12
OBJECT IDENTIFIER    

zxAnIeee1588TimeStatusConfObjs 1.3.6.1.4.1.3902.1082.120.15.1.13
OBJECT IDENTIFIER    

zxAnIeee1588PtpObjects 1.3.6.1.4.1.3902.1082.120.15.2.1
OBJECT IDENTIFIER    

zxAnIeee15881ppsObjects 1.3.6.1.4.1.3902.1082.120.15.2.2
OBJECT IDENTIFIER    

zxAnIeee1588PtpGlobalObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.1
OBJECT IDENTIFIER    

zxAnPtpMasterObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1
OBJECT IDENTIFIER    

zxAnPtpProfileObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.20
OBJECT IDENTIFIER    

zxAnPtpStatsObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.25
OBJECT IDENTIFIER    

zxAnPtpProfileGlobalObjects 1.3.6.1.4.1.3902.1082.120.15.2.1.20.1
OBJECT IDENTIFIER    

zxAnIeee1588GlobalTraps 1.3.6.1.4.1.3902.1082.120.15.3.1
OBJECT IDENTIFIER    

zxAnIeee1588PtpTraps 1.3.6.1.4.1.3902.1082.120.15.3.2
OBJECT IDENTIFIER    

zxAnIeee15881ppsTraps 1.3.6.1.4.1.3902.1082.120.15.3.3
OBJECT IDENTIFIER    

zxAnIeee1588Capabilities 1.3.6.1.4.1.3902.1082.120.15.1.1
The IEEE1588 capabilities of this equipment. The bit value 1 means the function represented by this bit is supported by this equipment. bit 0: value 1 means the following changes, adding zxAnPtpRemoteSrcPriority to the zxAnPtpRemoteSrcTable, adding zxAn1588LocalUtcTime to the zxAnIeee1588TimeStatusInfoObjs, adding zxAnPtpProtocolIpAddrPfxLen, zxAnPtpProtocolGatewayIpAddrType and zxAnPtpProtocolGatewayIpAddress to the zxAnPtpTable, adding zxAnSyncTime1ppsSrcFormat, zxAnSyncTime1ppsSrcCurrentQL, zxAnSyncTime1ppsSrcTimeAccuracy and zxAnSyncTime1ppsSrcTimeSrcType to the zxAnSyncTime1ppsSrcTable. bit 1: value 1 means the following changes, adding zxAnSyncTime1ppsSrcDlyCompensate to the zxAnSyncTime1ppsSrcTable. NOTE: No recommended to display it in NMS.
Status: current Access: read-only
OBJECT-TYPE    
  BITS from201602To201603(0), add1ppsSrcDelayCompensation(1)  

zxAn1588FreqQLThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.1
System frequency quality level threshold. A zxAnAccuracyDegradedAlm alarm will be generated when system frequency quality level is below the following threshold. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER qlprc(2), qlssua(4), qlssub(8), qlsec(11)  

zxAnPtpClockTraceClassThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.2
PTP clock traceability class threshold. A zxAnPtpClockTCBelowThreshAlm alarm will be generated when PTP traceability clock class is below threshold.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

zxAn1ppsInputSignalQLThresh 1.3.6.1.4.1.3902.1082.120.15.1.11.3
1PPS input signal quality level threshold. A zxAn1ppsInSignalQlBelowThreshAlm alarm will be generated when 1PPS input signal quality level of '1PPS+ToD' port is below the following threshold. locked(1): 1PPS input signal source is locked with grandmaster at this time. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. 1PPS input signal is in holdover state at this time by using PRC. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. 1PPS input signal is in holdover state at this time by using SSU-A. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. 1PPS input signal is in holdover state at this time by using SSU-B. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. 1PPS input signal is in holdover state at this time by using SEC.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER locked(1), qlprc(2), qlssua(4), qlssub(8), qlsec(11)  

zxAn1588TimeAccuracyDegradAlmRsn 1.3.6.1.4.1.3902.1082.120.15.1.12.1
The time accuracy degraded alarm reason. A zxAn1588TimeAccuracyDegradeAlm alarm will be generated because for the following threshold. freqLol(1): frequency loss of lock. freqQualityLevelBelowThresh(2): frequency quality level below threshold.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER freqLol(1), freqQualityLevelBelowThresh(2)  

zxAn1588TimeSourceType 1.3.6.1.4.1.3902.1082.120.15.1.12.2
The current time source type. none(1): no time source. ptp(2): PTP time source. oneppsPlusTod: 1PPS+ToD time source.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ptp(2), oneppsPlusTod(3)  

zxAn1588TimeSourceId 1.3.6.1.4.1.3902.1082.120.15.1.12.3
The current time source identification. It indicates the PTP time source ID when zxAn1588TimeSourceType is ptp(1). It indicates the 1PPS+ToD time source ID when zxAn1588TimeSourceType is oneppsPlusTod(2). If zxAn1588TimeSourceType is none(1), the attribute value is empty string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..23)  

zxAn1588LocalTimeStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.4
The local time status. freeRun(1): the local time has never been synchronized with any time source. synchronizing(2): the local time is synchronizing with a time source. locked(3): the local time has been synchronized with a time source. holdoverInspecification(4): the local time is no longer synchronized with a time source and is using information obtained while it was previously synchronized or other information sources were still available, to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdoverOutOfSpecification(5): the local time is no longer synchronized with a time source and, while it may be using information obtained while it was previously synchronized or other information sources were still available, it is unable to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdover(6): the local time is no longer synchronized with a time source, this value is only used for zxAn1588LocalTimeStatusChanged trap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), synchronizing(2), locked(3), holdoverInSpecification(4), holdoverOutOfSpecification(5), holdover(6)  

zxAn1588LocalClockFreqStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.5
The local clock frequency status. freerun(1): the local clock frequency is in free-run state. locked(2): the local clock frequency is in locked state. holdover(3): the local clock frequency is in holdover state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), locked(2), holdover(3)  

zxAn1588LocalClockFreqQltyLvl 1.3.6.1.4.1.3902.1082.120.15.1.12.6
The local clock frequency quality level. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. 1PPS input signal is in holdover state at this time by using PRC. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER qlprc(2), qlssua(4), qlssub(8), qlsec(11)  

zxAn1588PtpMessageReceiveStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.7
The PTP message receiving status. normal(1): the PTP message receiving status is normal. annocMessageMissed(2): the PTP announcement message is missed. syncMessageMissed(3): the PTP synchronization message is missed. annocAndSyncMessagesMissed(4): the PTP announcement and synchronization messages are all missed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), annocMessageMissed(2), syncMessageMissed(3), annocAndSyncMessagesMissed(4)  

zxAn1588LastTimeSourceType 1.3.6.1.4.1.3902.1082.120.15.1.12.8
The last time source type. none(1): no time source. ptp(2): PTP time source. oneppsPlusTod: 1PPS+ToD time source.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), ptp(2), oneppsPlusTod(3)  

zxAn1588LastTimeSourceId 1.3.6.1.4.1.3902.1082.120.15.1.12.9
The last time source identification. It indicates the PTP time source ID when zxAn1588TimeSourceType is ptp(1). It indicates the 1PPS+ToD time source ID when zxAn1588TimeSourceType is oneppsPlusTod(2). If zxAn1588TimeSourceType is none(1), the attribute value is empty string.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..23)  

zxAn1588LocalUtcTime 1.3.6.1.4.1.3902.1082.120.15.1.12.10
The UTC time of Local clock. The format is yyyy-mm-dd HH:MM:SS.For example, 2001-01-01 02:22:33.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..19)  

zxAn1588LastLocalTimeStatus 1.3.6.1.4.1.3902.1082.120.15.1.12.11
The last local time status. freeRun(1): the local time has never been synchronized with any time source. synchronizing(2): the local time is synchronizing with a time source. locked(3): the local time has been synchronized with a time source. holdoverInspecification(4): the local time is no longer synchronized with a time source and is using information obtained while it was previously synchronized or other information sources were still available, to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdoverOutOfSpecification(5): the local time is no longer synchronized with a time source and, while it may be using information obtained while it was previously synchronized or other information sources were still available, it is unable to maintain performance within desired specification. It is defined in recommendation G.8275.1 appendix V. holdover(6): the local time is no longer synchronized with a time source, this value is only used for zxAn1588LocalTimeStatusChanged trap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER freeRun(1), synchronizing(2), locked(3), holdoverInSpecification(4), holdoverOutOfSpecification(5), holdover(6)  

zxAnIeee1588TimeStatusDftPri1 1.3.6.1.4.1.3902.1082.120.15.1.13.1
The default value of priority 1 delivered to PTP master. This value will be used when OLT is in holdover state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

zxAnIeee1588TimeStatusDftPri2 1.3.6.1.4.1.3902.1082.120.15.1.13.2
The default value of priority 2 delivered to PTP master, This value will be used when OLT is in holdover state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

zxAnIeee1588TimeStatusDftClkCls 1.3.6.1.4.1.3902.1082.120.15.1.13.3
The default value of clock class delivered to PTP master, This value will be used when OLT is in holdover state.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstDomainId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.1
The domain identification of the master. It is a logic number and the range is from 0 to 255, the value 0 indicates the default domain.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstIsLeap59 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.2
In PTP systems whose epoch is the PTP epoch, the value 'yes' indicates that the last minute of the current UTC day contains 59 seconds, the value 'no' indicates that the last minute of the current UTC day does not contain 59 seconds or the epoch is not PTP epoch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstIsLeap61 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.3
In PTP systems whose epoch is the PTP epoch, the value 'yes' indicates that the last minute of the current UTC day contains 61 seconds, the value 'no' indicates that the last minute of the current UTC day does not contain 61 seconds or the epoch is not PTP epoch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstIsTimeTraceable 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.4
The value 'yes' indicates that the current UTC offset can be traced to a primary reference and 'no' otherwise.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstIsFreqTraceable 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.5
The value 'yes' indicates that the time frequency can be traced to a primary reference and 'no' otherwise.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstIsUtcOffsetValid 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.6
The value 'yes' indicates that the current UTC offset is known to be valid and 'no' otherwise.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstCurrentUtcOffset 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.7
The current UTC offset between TAI(International Atomic Time) and UTC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

zxAnPtpMstClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.8
The master clock identity. This attribute value is hexadecimal data.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnPtpMstGrdmstClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.9
The grandmaster clock identity. This attribute value is hexadecimal data.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnPtpMstGrdmstIsPtpTimescale 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.10
The value 'yes' indicates that the clock timescale of the grandmaster clock is PTP and 'no' otherwise.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

zxAnPtpMstGrdmstPriority1 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.11
The grandmaster clock priority 1. The value 0 indicates the highest priority.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstGrdmstPriority2 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.12
The grandmaster clock priority 2. The value 0 indicates the highest priority.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstGrdmstClockTraceClass 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.13
The grandmaster clock traceability class of the time or frequency distributed. The value 0 indicates the best traceability class.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstGrdmstClockAccuracy 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.14
The grandmaster clock accuracy. The value 0 indicates the highest clock accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpMstGrdmstClockOslv 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.15
The grandmaster clock offset scaled log variance. It is computed based on the theory of Allan deviation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

zxAnPtpMstGrdmstTraversedClocks 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.16
The clocks traversed between the local clock and the grandmaster clock.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..65535  

zxAnPtpMstGrdmstTimeSource 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.17
The source of time used by the grandmaster clock.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER atomicClock(16), gps(32), terrestrialRadio(48), ptp(64), ntp(80), handset(96), other(144), internalOscillator(160)  

zxAnPtpMstSourcePortLocation 1.3.6.1.4.1.3902.1082.120.15.2.1.1.1.18
The source port location. uplinkCard(1): it means that the PTP master source port is located at the uplink card. masterControlCard(2): it means that the PTP master source port is located at the master control card. slaveControlCard(3): it means that the PTP master source port is located at the slave control card.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uplinkCard(1), masterControlCard(2), slaveControlCard(3)  

zxAnPtpIfConfTable 1.3.6.1.4.1.3902.1082.120.15.2.1.7
The IEEE 1588 PTP port table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPtpIfConfEntry

zxAnPtpIfConfEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1
The IEEE 1588 PTP port entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPtpIfConfEntry  

zxAnPtpIfConfClockId 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.1
The PTP port clock identity. This attribute value is hexadecimal data.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

zxAnPtpIfConfNumber 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.2
The PTP port number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpIfConfState 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.3
The PTP port state.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER initializing(1), faulty(2), disabled(3), listening(4), preMaster(5), master(6), passive(7), uncalibrated(8), slave(9)  

zxAnPtpIfConfMinDelayReqInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.4
The minimum interval between successive Delay_Req messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER us31250(1), us62500(2), us125000(3), us250000(4), us500000(5), oneSecond(6)  

zxAnPtpIfConfAnnounceInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.6
The interval between successive Announce messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER us31250(1), us62500(2), us125000(3), us250000(4), us500000(5), oneSecond(6)  

zxAnPtpIfConfMaxLossAnnounceMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.7
The maximum number of Announce messages loss.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 2..255  

zxAnPtpIfConfSyncInterval 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.8
The interval between successive synchronization messages. us31250 means interval 2**(-5)s us62500 means interval 2**(-4)s us125000 means interval 2**(-3)s us250000 means interval 2**(-2)s us500000 means interval 2**(-1)s oneSecond means interval 2**(0)s
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER us31250(1), us62500(2), us125000(3), us250000(4), us500000(5), oneSecond(6)  

zxAnPtpIfConfLocalPriority 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.13
The PTP port local priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

zxAnPtpIfConfPtpMsgProtocolType 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.21
The PTP message protocol type. ipv4(1): it means the PTP messages is IPv4 protocol. ethernet(2): it means the PTP messages is Ethernet protocol.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ipv4(1), ethernet(2)  

zxAnPtpIfConfAddressType 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.22
The PTP port address type. multicast(1): it means the PTP port address type is multicast. unicast(2): it means the PTP port address type is unicast.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER multicast(1), unicast(2)  

zxAnPtpIfConfMsgForwardOption 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.23
The PTP message forwarding option. forwardable(1): it means the PTP messages is preferable to forward the PTP messages through the PTP port. nonforwardable(2): it means the PTP messages must never be forwarded through the PTP port.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER forwardable(1), nonforwardable(2)  

zxAnPtpIfConfDelayCompensation 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.24
The PTP port delay compensation.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -100000..100000  

zxAnPtpIfConfAdminStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.25
The PTP port administrative status. Enables or disables the PTP port.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

zxAnPtpIfConfRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.7.1.50
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnPtpPrfSystemPtpPrf 1.3.6.1.4.1.3902.1082.120.15.2.1.20.1.1
The system PTP profile name. Refers to 'zxAnPtpPrfName'. An empty string indicates no binding any profile.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..40)  

zxAnPtpPrfTable 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2
The IEEE 1588 PTP profile table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPtpPrfEntry

zxAnPtpPrfEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1
The IEEE 1588 PTP profile entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPtpPrfEntry  

zxAnPtpPrfName 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.1
The PTP profile name.
Status: current Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(1..40)  

zxAnPtpPrfPriority2 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.3
The PTP priority 2. The value 0 indicates the highest priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..255  

zxAnPtpPrfDomainNumber 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.4
The PTP domain number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 24..43  

zxAnPtpPrfLocalPriority 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.5
The PTP local priority. The value 1 indicates the highest priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

zxAnPtpPrfMaxStepsRemoved 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.6
The PTP maximum steps removed. The parameter is defined in [IEEE1588] is used to indicate the distance between a clock and the grandmaster clock in the network. It was originally intended to be used as a helpful tool to detect cyclic paths that may occur in PTP systems. By default it is required that a clock not qualify any Announce messages where the stepsRemoved field is equal to, or greater than, 255 in order to ensure that rogue frames are extinguished.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

zxAnPtpPrfBmcaOption 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.7
The PTP BMCA (best master clock algorithm) option. g82751(1): BMCA complies with G.8275.1. ieee1588(2): BMCA complies with IEEE 1588.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER g82751(1), ieee1588(2)  

zxAnPtpPrfTraceOption 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.8
The PTP trace option. g82751(1): PTP trace complies with G.8275.1. g82751note3(2): PTP trace complies with G.8275.1 note 3. ieee1588(3): PTP trace complies with IEEE 1588.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER g82751(1), g82751note3(2), ieee1588(3)  

zxAnPtpPrfHoldoverInTimeout 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.9
The holdover-in timeout. The value 0 indicates that the system clock do not enter into the holdover-in status.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1440  

zxAnPtpPrfRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.1.20.2.1.50
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnPtpIfStatsTable 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2
The IEEE 1588 PTP port statistics table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnPtpIfStatsEntry

zxAnPtpIfStatsEntry 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1
The IEEE 1588 PTP port statistics entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnPtpIfStatsEntry  

zxAnPtpIfStatsAnnounceMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.1
The number of PTP announce messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zxAnPtpIfStatsSyncMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.2
The number of PTP synchronization messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zxAnPtpIfStatsDelayReqMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.3
The number of PTP delay_req messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zxAnPtpIfStatsDelayRespMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.4
The number of PTP delay_resp messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zxAnPtpIfStatsFollowUpMsgs 1.3.6.1.4.1.3902.1082.120.15.2.1.25.2.1.5
The number of PTP follow_up messages.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

zxAnSyncTime1ppsSrcTable 1.3.6.1.4.1.3902.1082.120.15.2.2.3
This table includes 1PPS source information in NE equipment.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnSyncTime1ppsSrcEntry

zxAnSyncTime1ppsSrcEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1
An entry in zxAnSyncTime1ppsSrcTable. to create a 1pps source,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create 1PPS signal source from 1PPS port: -Mandatory: zxAnSyncTime1ppsSrcRack, zxAnSyncTime1ppsSrcShelf, zxAnSyncTime1ppsSrcSlot, zxAnSyncTime1ppsSrcSignalType, zxAnSyncTime1ppsSrcPortType, zxAnSyncTime1ppsSrcPort, zxAnSyncTime1ppsSrcPriority, zxAnSyncTime1ppsSrcRowStatus, -Optional: case 3 - to destroy 1PPS signal -Mandatory: zxAnSyncTime1ppsSrcRowStatus,
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnSyncTime1ppsSrcEntry  

zxAnSyncTime1ppsSrcId 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.1
This '1PPS+ToD' source id.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

zxAnSyncTime1ppsSrcRack 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.2
This object indicates the rack number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTime1ppsSrcShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.3
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTime1ppsSrcSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.4
This object indicates the slot number. Only support time card, such as cick.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnSyncTime1ppsSrcFirstPtp 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.5
The PTP node provided '1PPS+ToD' siginal is the first node of this slot or not.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

zxAnSyncTime1ppsSrcSignalType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.6
The type of '1PPS+ToD' signal source. ptp(1) : 1PPS come from PTP onepps(2) : 1PPS come from physical 1pps port
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ptp(1), onepps(2)  

zxAnSyncTime1ppsSrcPriority 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.7
The priority of '1PPS+ToD' signal source, value 1 is the highest priority.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

zxAnSyncTime1ppsSrcPortType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.8
The '1PPS+ToD' signal source port type. It is valid only for the 'onepps' signal type. typeTtl(1) : physical port type TTL type422(2) : from physical port as RJ45
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER typeTtl(1), type422(2)  

zxAnSyncTime1ppsSrcPort 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.9
The physical port number. It is valid only for the 'onepps' signal type.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..4  

zxAnSyncTime1ppsSrcWorkStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.10
The '1PPS+ToD' signal source work status, none(1) : indicates PTP source is invalid. active(2) : indicates PTP source is active, standby(3) : indicates PTP source is standby source,
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), active(2), standby(3)  

zxAnSyncTime1ppsSrcValidStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.11
The '1PPS+ToD' singnal source work status. valid(1) : indicates the 1PPS signal is valid invalid(2): indicates the 1PPS signal is invalid When the value is invalid, then zxAnSyncTime1ppsSrcWorkStatus is none.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), invalid(2)  

zxAnSyncTime1ppsSrcPortStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.12
The '1PPS+ToD' signal source port status. It is valid only for the 'onepps' signal type. If zxAnSyncTime1ppsSrcSignalType is 'ptp', then the value is none. When the value is none or signalLos, then zxAnSyncTime1ppsSrcValidStatus is invalid.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), normal(2), signalLos(3)  

zxAnSyncTime1ppsSrcFormat 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.13
The '1PPS+ToD' singnal source format. unknown(1): it indicates the '1PPS+ToD' signal source format is unknown. gpzda(2): it indicates the '1PPS+ToD' signal source format is GPZDA. gprmc(3): it indicates the '1PPS+ToD' signal source format is GPRMC. cmcc(4): it indicates the '1PPS+ToD' signal source format is CMCC.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), gpzda(2), gprmc(3), cmcc(4)  

zxAnSyncTime1ppsSrcCurrentQL 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.14
The '1PPS+ToD' singnal source current quality level. locked(1): 1PPS input signal source is locked with grandmaster at this time. qlprc(2): quality level of primary reference clock, it is defined in recommendation G.811. qlssua(4): quality level of type I/V slave clock, it is defined in recommendation G.812. qlssub(8): quality level of type VI slave clock, it is defined in recommendation G.812. qlsec(11): quality level of SDH equipment clock, it is defined in recommendation G.813. qldnu(15): quality level of unusable clock, it is defined in recommendation G.813.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER locked(1), qlprc(2), qlssua(4), qlssub(8), qlsec(11), qldnu(15)  

zxAnSyncTime1ppsSrcTimeAccuracy 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.15
The '1PPS+ToD' singnal source time accuracy, value 0 indicates the highest accuracy.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..3810  

zxAnSyncTime1ppsSrcTimeSrcType 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.16
The '1PPS+ToD' singnal source time source type. bds(1): the time source type is beidou bavigation satellite system. gps(2): the time source type is global positioning system. ptp(3): the time source type is precision timing protocol system. other(255): the time source type is other system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER bds(1), gps(2), ptp(3), other(255)  

zxAnSyncTime1ppsSrcDlyCompensate 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.17
The '1PPS+ToD' delay compensation.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..10000  

zxAnSyncTime1ppsSrcRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.3.1.30
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnSyncTimeTodSrcTable 1.3.6.1.4.1.3902.1082.120.15.2.2.4
This table includes TOD source information in NE equipment.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnSyncTimeTodSrcEntry

zxAnSyncTimeTodSrcEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1
An entry in zxAnSyncTimeTodSrcTable. to create a TOD source,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create tod source from physical tod port: -Mandatory: zxAnSyncTimeTodSrcRack, zxAnSyncTimeTodSrcShelf, zxAnSyncTimeTodSrcSlot, zxAnSyncTimeTodSrcPort, zxAnSyncTimeTodSrcSignalType, zxAnSyncTimeTodSrcRowStatus, -Optional: zxAnSyncTimeTodSrcYearAdjust, case 2 - to destroy tod source -Mandatory: zxAnSyncTimeTodSrcRowStatus,
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnSyncTimeTodSrcEntry  

zxAnSyncTimeTodSrcId 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.1
This tod source id.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

zxAnSyncTimeTodSrcRack 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.2
This object indicates the rack number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTimeTodSrcShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.3
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTimeTodSrcSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.4
This object indicates the slot number. Only support time card, such as cick.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnSyncTimeTodSrcPort 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.5
This object indicates the port number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

zxAnSyncTimeTodSrcSignalType 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.6
The signal type of TOD signal source. gps(1) : GPS TOD form chinaMobile(2) : China Mobile Telecom's TOD form chinaUnicom(3) : China Unicom Telecom's TOD form chinaTelecom(4): China Telecom's TOD form
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER gps(1), chinaMobile(2), chinaUnicom(3), chinaTelecom(4)  

zxAnSyncTimeTodSrcYearAdjust 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.7
The year adjustment value of TOD signal source. It is valid only for the 'gps' signal type.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..2050  

zxAnSyncTimeTodSrcPortStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.8
The TOD signal source port status. none(1) : none normal(2) : no alarm signalLos(3) : Loss of TOD
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), normal(2), signalLos(3)  

zxAnSyncTimeTodSrcRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.4.1.30
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnSyncTimeOutputPortTable 1.3.6.1.4.1.3902.1082.120.15.2.2.5
This table includes 1PPS and TOD signal output ports information in NE equipment.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnSyncTimeOutputPortEntry

zxAnSyncTimeOutputPortEntry 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1
An entry in zxAnSyncTimeOutputPortTable. to create a TOD output,it must comply with the multi-variables usage rule - all the mib variables related to same fuction must be in one snmp set operation. the variables have two type mandatory and optional: Mandatory variables must be in the one snmp set operation. Optional variables may be in the one snmp set operation with the mandatory variables, but must not be used alone. case 1 - to create tod output: -Mandatory: zxAnSyncTimeOutputRack, zxAnSyncTimeOutputShelf, zxAnSyncTimeOutputSlot, zxAnSyncTimeOutputPort, zxAnSyncTimeOutputPortEnable, zxAnSyncTimeOutputPortRowStatus, -Optional: case 3 - to destroy tod output -Mandatory: zxAnSyncTimeOutputPortRowStatus,
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnSyncTimeOutputPortEntry  

zxAnSyncTimeOutputId 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.1
This time output id.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32  

zxAnSyncTimeOutputRack 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.2
This object indicates the rack number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTimeOutputShelf 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.3
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnSyncTimeOutputSlot 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.4
This object indicates the slot number. Only support pon card.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnSyncTimeOutputPort 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.5
This object indicates the port number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..8  

zxAnSyncTimeOutputPortEnable 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.6
Enables or disables the output port of 1PPS and TOD signal. enable(1) : enable disable(2): disable
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

zxAnSyncTimeOutputPortPhaseAdjus 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.7
The phase adjustment value. It is valid only for the 1PPS signal.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1000000..1000000  

zxAnSyncTimeOutputPortRowStatus 1.3.6.1.4.1.3902.1082.120.15.2.2.5.1.30
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). To delete a row in this table, a manager must set this object to destroy(6). To query this object, always return 1.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAn1588TimeAccuracyDegradeAlm 1.3.6.1.4.1.3902.1082.120.15.3.1.1
A zxAnAccuracyDegradedAlm trap is sent when the agent has detected that the time accuracy has been degraded.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1588TimeAccuracyDegradeClr 1.3.6.1.4.1.3902.1082.120.15.3.1.2
A zxAn1588TimeAccuracyDegradeClr trap is sent when the agent has detected that the time accuracy has come into the accurate status.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1588TimeSourceChanged 1.3.6.1.4.1.3902.1082.120.15.3.1.3
A zxAn1588TimeSourceChanged trap is sent when the agent has detected that the current time source of IEEE1588 device has been changed to another new time source.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1588LocalTimeStatusChanged 1.3.6.1.4.1.3902.1082.120.15.3.1.4
A zxAn1588LocalTimeStatusChanged trap is sent when the agent has detected that the current time status of IEEE1588 device has been changed to another new time status.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpNeverSyncAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.1
A zxAnPtpNeverSyncAlm trap is sent when the agent has detected that the PTP clock has never been synchronized with a time source.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpNeverSyncClr 1.3.6.1.4.1.3902.1082.120.15.3.2.2
A zxAnPtpNeverSyncClr trap is sent when the agent has detected that the PTP clock has been synchronized with a time source.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpLolAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.3
A zxAnPtpLolAlm trap is sent when the agent has detected that the PTP clock was in the loss of lock status.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpLolClr 1.3.6.1.4.1.3902.1082.120.15.3.2.4
A zxAnPtpLolClr trap is sent when the agent has detected that the PTP clock has been locked again.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpClockTCBelowThreshAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.5
A zxAnPtpClockTCBelowThreshAlm trap is sent when the agent has detected that the PTP clock traceability class has been below zxAnPtpClockTraceClassThresh threshold.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpClockTCBelowThreshClr 1.3.6.1.4.1.3902.1082.120.15.3.2.6
A zxAnPtpClockTCBelowThreshClr trap is sent when the agent has detected that the PTP clock traceability class has not been below zxAnPtpClockTraceClassThresh threshold.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpAnnounceMsgLostAlm 1.3.6.1.4.1.3902.1082.120.15.3.2.7
A zxAnPtpAnnounceMsgLostAlm trap is sent when the agent has detected that the announce messages lost.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnPtpAnnounceMsgLostClr 1.3.6.1.4.1.3902.1082.120.15.3.2.8
A zxAnPtpAnnounceMsgLostClr trap is sent when the agent has detected that the announce messages are received again.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1ppsPlusTodLosAlm 1.3.6.1.4.1.3902.1082.120.15.3.3.1
A zxAn1ppsPlusTodLosAlm trap is sent when the agent has detected that the '1PPS+ToD' port was in the loss of signal status.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1ppsPlusTodLosClr 1.3.6.1.4.1.3902.1082.120.15.3.3.2
A zxAn1ppsPlusTodLosClr trap is sent when the agent has detected that the '1PPS+ToD' port has restored signal.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1ppsInSignalQlBelowThreshAlm 1.3.6.1.4.1.3902.1082.120.15.3.3.3
A zxAn1ppsInSignalQlBelowThreshAlm trap is sent when the agent has detected that the 1PPS input signal quality level of '1PPS+ToD' port has been below zxAn1ppsInputSignalQLThresh threshold.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAn1ppsInSignalQlBelowThreshClr 1.3.6.1.4.1.3902.1082.120.15.3.3.4
A zxAn1ppsInSignalQlBelowThreshClr trap is sent when the agent has detected that the 1PPS input signal quality level of '1PPS+ToD' port has not been below zxAn1ppsInputSignalQLThresh threshold.
Status: current Access: read-create
NOTIFICATION-TYPE    

zxAnIeee1588Conformance 1.3.6.1.4.1.3902.1082.120.15.4
OBJECT IDENTIFIER    

zxAnIeee1588Compliances 1.3.6.1.4.1.3902.1082.120.15.4.1
OBJECT IDENTIFIER    

zxAnIeee1588Groups 1.3.6.1.4.1.3902.1082.120.15.4.2
OBJECT IDENTIFIER    

zxAnIeee1588Compliance 1.3.6.1.4.1.3902.1082.120.15.4.1.1
The compliance statement for entities which implement the Zte An IEEE1588 MIB. Implementation of this MIB is based on individual product needs.
Status: current Access: read-create
MODULE-COMPLIANCE    

zxAnIeee1588PtpPrfObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.1
A collection of objects providing IEEE1588 functions.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588PtpIfObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.2
A collection of objects providing IEEE1588 port functions.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee15881ppsObjectsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.3
A collection of global objects providing 1PPS functions.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588PtpMstInfoGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.4
A collection of objects providing PTP master information.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588TimeStatusGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.5
A collection of objects providing time status information.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588PktStatsGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.6
A collection of objects providing packets statistics.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588AlmThreshGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.7
A collection of objects providing alarm thresholds.
Status: current Access: read-create
OBJECT-GROUP    

zxAnIeee1588AlmTrapGroup 1.3.6.1.4.1.3902.1082.120.15.4.2.8
A collection of objects providing 1588 alarm functions
Status: current Access: read-create
OBJECT-GROUP