ZTE-AN-CLOCK-MIB

File: ZTE-AN-CLOCK-MIB.mib (40548 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC
ZTE-AN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-GROUP NOTIFICATION-GROUP
OBJECT-TYPE NOTIFICATION-TYPE Integer32
RowStatus zxAnClockSync MODULE-COMPLIANCE

Defined Types

ZxAnClockSrcEntry  
SEQUENCE    
  zxAnClockSrcId Integer32
  zxAnClockSrcShelf Integer32
  zxAnClockSrcSlot Integer32
  zxAnClockSrcPort Integer32
  zxAnClockSrcType INTEGER
  zxAnClockSrcPriority Integer32
  zxAnClockSrcTxS1 Integer32
  zxAnClockSrcRxS1 Integer32
  zxAnClockSrcAlarm INTEGER
  zxAnClockSrcExtInQuality INTEGER
  zxAnClockSrcExtInMode INTEGER
  zxAnClockSrcSwitchMode INTEGER
  zxAnClockSrcEntryStatus RowStatus

ZxAnClockSsmSendEntry  
SEQUENCE    
  zxAnClockSsmSendId Integer32
  zxAnClockSsmSendShelf Integer32
  zxAnClockSsmSendSlot Integer32
  zxAnClockSsmSendPort Integer32
  zxAnClockSsmSendBytes Integer32
  zxAnClockSsmSendRowStatus RowStatus

ZxAnClockEsmcEntry  
SEQUENCE    
  zxAnClockEsmcId Integer32
  zxAnClockEsmcShelf Integer32
  zxAnClockEsmcSlot Integer32
  zxAnClockEsmcPort Integer32
  zxAnClockEsmcRowStatus RowStatus

ZxAnClockCardClockConfEntry  
SEQUENCE    
  zxAnClockCardClockConfRack Integer32
  zxAnClockCardClockConfShelf Integer32
  zxAnClockCardClockConfSlot Integer32
  zxAnClockCardClockConfType INTEGER

Defined Values

zxAnClockMib 1.3.6.1.4.1.3902.1082.120.10
The MIB module for the management of Clock.
MODULE-IDENTITY    

zxAnClockGlobalObjects 1.3.6.1.4.1.3902.1082.120.10.1
OBJECT IDENTIFIER    

zxAnClockObjects 1.3.6.1.4.1.3902.1082.120.10.2
OBJECT IDENTIFIER    

zxAnClockNotifications 1.3.6.1.4.1.3902.1082.120.10.3
OBJECT IDENTIFIER    

zxAnClockConformance 1.3.6.1.4.1.3902.1082.120.10.4
OBJECT IDENTIFIER    

zxAnClockSrcFunc 1.3.6.1.4.1.3902.1082.120.10.2.1
OBJECT IDENTIFIER    

zxAnClockSsmFunc 1.3.6.1.4.1.3902.1082.120.10.2.2
OBJECT IDENTIFIER    

zxAnClockCardClockConfFunc 1.3.6.1.4.1.3902.1082.120.10.2.3
OBJECT IDENTIFIER    

zxAnClockTraps 1.3.6.1.4.1.3902.1082.120.10.3.1
OBJECT IDENTIFIER    

zxAnClockExtOutQlMinimum 1.3.6.1.4.1.3902.1082.120.10.1.1
The ssm threshold to open or close external output clock(T4). open : QL >= zxAnClockExtOutQlMinimum close : QL < zxAnClockExtOutQlMinimum First time to set this object: zxAnClockExtOutMode must be set together, and inhibit zxAnClockExtOutQlMinimum be ssmNULL or zxAnClockExtOutMode be clockNULL. normal set: will change the ssm threshold. SsmNULL value only can be set when zxAnClockExtOutMode is setted clockNULL, means destroy the config of external output clock. get: ssmNull means no external output clock config
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER qlprc(2), qlssua(4), qlssub(8), qlsec(11), ssmNULL(255)  

zxAnClockExtOutMode 1.3.6.1.4.1.3902.1082.120.10.1.2
Mode of external output clock. First time to set this object: zxAnClockExtOutQlMinimum must be set together, and inhibit zxAnClockExtOutQlMinimum be ssmNULL or zxAnClockExtOutMode be clockNULL. Normal operator: change external output clock mode; clockNULL value only can be set when zxAnClockExtOutQlMinimum is setted ssmNull, means destroy the config of external output clock.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER hz(1), readableSsm(2), unreadableSsm(3), clockNULL(255)  

zxAnClockWorkMode 1.3.6.1.4.1.3902.1082.120.10.1.3
This attribute specifies the clock work mode comply with G.781 section 5.12 Automatic reference selection process.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER qlenable(1), qldisable(2)  

zxAnClockWaitToRestoreTime 1.3.6.1.4.1.3902.1082.120.10.1.4
This attribute specifies the clock source wait to restore time, comply with G.781 section 5.9 wait to restore time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..12  

zxAnClockHoldOffTime 1.3.6.1.4.1.3902.1082.120.10.1.5
This attribute specifies the clock source hold-off Time, comply with G.781 section 5.8 hold-off time.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 300..1800  

zxAnClockOperationStatus 1.3.6.1.4.1.3902.1082.120.10.1.6
This attribute specifies clock operation status. freerunPhaselockedNormal,holdOver: set means force PLL switch to freerun/holdover state. geted means PLL is forced by freerun/holdover operator. destoryFreerunOrHoldOver: write only, means destroy freerun/holdover operator. unknown: read only, means no any force operator exist.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER freerunPhaselockedNormal(1), holdOver(2), destoryFreerunOrHoldOver(21), unknown(255)  

zxAnClockActiveId 1.3.6.1.4.1.3902.1082.120.10.1.7
Active clock id. If get zero,means Internal clock is active. If not,means zxAnClockActiveId is a giving zxAnClockSrcId which related to a record of zxAnClockSrcTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnClockPllState 1.3.6.1.4.1.3902.1082.120.10.1.8
state of pll. preLocked2: This state is very similar to the preLocked state. It is entered from the Holdover state when a reference source has been selected and applied to the phase locked loop.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pllFreerun(1), holdOver(2), locked(4), preLocked2(5), preLocked(6), outOfPhase(7), pllWrong(11)  

zxAnClockSrcSwitchReason 1.3.6.1.4.1.3902.1082.120.10.1.9
clock source switch reason: 1, CLOCKSOURCE_SWITCH_ABMNORMAL, 2, CLOCKSOURCE_SWITCH_S1CHANGE, 3, CLOCKSOURCE_SWITCH_ALMCHANGE, 4, CLOCKSOURCE_SWITCH_PRICHANGE, 5, CLOCKSOURCE_SWITCH_OUTOFLOCK, 6, CLOCKSOURCE_SWITCH_DEGRADE, 7, LOCKSOURCE_SWITCH_PLLFAIL, 8, CLOCKSOURCE_SWITCH_PRELOCKFAIL, 9, CLOCKSOURCE_SWITCH_HOLDOVESTOP, 10, CLOCKSOURCE_SWITCH_LOADCFG, 11, CLOCKSOURCE_SWITCH_ALMRESTORE, 12, CLOCKSOURCE_SWITCH_PROTECT, 13, CLOCKSOURCE_SWITCH_PROTECT_CANCEL, 14, CLOCKSOURCE_SWITCH_BACKUP_PLLFAIL,
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zxAnClockSrcSwitchOldInfo 1.3.6.1.4.1.3902.1082.120.10.1.10
the active clock source identify before switch: |shelf| slot | port |clockType| 0000 0000 0000 0000 0000 0000 0000 0000 clockType: 0: internal clock 2: external clock 3: E1 clock not supported this version 6: synchronous ethernet equipment clock 7: SDH clock not supported this version 8: PTP clock not supported this version
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zxAnClockSrcSwitchNewInfo 1.3.6.1.4.1.3902.1082.120.10.1.11
the active clock source identify after switch: |shelf| slot | port |clockType| 0000 0000 0000 0000 0000 0000 0000 0000 clockType: 0: internal clock 2: external clock 3: E1 clock not supported this version 6: synchronous ethernet equipment clock 7: SDH clock not supported this version 8: PTP clock not supported this version
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

zxAnClockLastPllStatus 1.3.6.1.4.1.3902.1082.120.10.1.12
The last status of clock PLL.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pllFreerun(1), holdOver(2), locked(4), preLocked2(5), preLocked(6), outOfPhase(7), pllWrong(11)  

zxAnClockSrcTable 1.3.6.1.4.1.3902.1082.120.10.2.1.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnClockSrcEntry

zxAnClockSrcEntry 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1
ClockSource entry. Entries in the zxClockSrcTable are created and deleted by using zxAnClockSrcEntryStatus object. When create the zxClockSrcTable, zxAnClockSrcShelf, zxAnClockSrcSlot, zxAnClockSrcPort, zxAnClockSrcType, zxAnClockSrcPriority must be setted together. zxAnClockSrcExtInQuality and zxAnClockSrcExtInMode must be setted when creating externalClock, zxAnClockSrcShelf, zxAnClockSrcSlot,zxAnClockSrcPort, zxAnClockSrcType and zxAnClockSrcExtInMode do not support modify. only one EEC port can be configed per card of which supporting synchronous ethernet equipment clock
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnClockSrcEntry  

zxAnClockSrcId 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.1
clock source id
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

zxAnClockSrcShelf 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.2
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnClockSrcSlot 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.3
This object indicates the slot number. In IEC19Shelf type ,value 21,22 are not supported.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnClockSrcPort 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.4
This object indicates the port number. 0 is only used for internal clock source. 1-4 is used for uplink card. 1-2 is used for common interface card, and other clock support card(CES) .
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..4  

zxAnClockSrcType 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.5
This object indicates the source type internalClock,maintainClock for master card externalClock for interface card e1Clock not supported this version stm1Clock,stm4Clock,sdhClock not supported this version syncEth for syncE card ptpClock not supported this version This object can not be modified.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER internalClock(1), maintainClock(2), externalClock(3), e1Clock(4), stm1Clock(5), stm4Clock(6), syncEth(7), sdhClock(8), ptpClock(9)  

zxAnClockSrcPriority 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.6
1 has the highest priority. Priority can be write 1-250, when zxClockSrcPriority is created and modified.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..250  

zxAnClockSrcTxS1 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.7
transmitted QL-level
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..15  

zxAnClockSrcRxS1 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.8
received QL-level. 16-254 not supported.255 means not received QL-level.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..255  

zxAnClockSrcAlarm 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.9
This attribute specifies alarm of this clock reference source. normal: the alarm status is normal, this value is disused. abnormal: the alarm status is abnormal, this value is disused. los: loss of signal status. lockAlam: exceed of frequency status. s1Mismatch:S1 mismatch status. lockOut: lockOut status. qlFail: quality level fail status. lostEsmc: loss of ESMC status. waitToRecover: wait the clock source to recover. noAlarm: no alarm, the normal status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), abnormal(2), los(3), lockAlam(4), s1Mismatch(5), lockOut(6), qlFail(7), lostEsmc(8), waitToRecover(9), noAlarm(255)  

zxAnClockSrcExtInQuality 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.10
Quality level of input clock. This object must be written with a certain value excluding SsmNULL when creating external clock.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER qlprc(2), qlssua(4), qlssub(8), qlsec(11), qldnu(15), ssmNULL(255)  

zxAnClockSrcExtInMode 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.11
Mode of external input clock. This object must be written with a certain value excluding clockNULL when creating external clock.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER hz(1), readableSsm(2), unreadableSsm(3), clockNULL(255)  

zxAnClockSrcSwitchMode 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.12
This attribute specifies clock source switch mode in G.781. none: no switch operator on or be locked out. forced: force switch on. manual: manual switch on. lockOut: be locked out.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER none(1), forced(2), manual(3), lockOut(4)  

zxAnClockSrcEntryStatus 1.3.6.1.4.1.3902.1082.120.10.2.1.1.1.50
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). In particular, a newly created row cannot be created until the corresponding zxAnClockSrcId and zxAnClockSrcShelf and zxAnClockSrcSlot and zxAnClockSrcIPort and zxAnClockSrcType and zxAnClockSrcPriority have been set. To delete a row in this table, a manager must set this object to destroy(6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnClockSsmSendTable 1.3.6.1.4.1.3902.1082.120.10.2.2.1
SSM/QL-level overwriting management of clock tx port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnClockSsmSendEntry

zxAnClockSsmSendEntry 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1
It is entry in the zxClockSsmSendTable. Entries in the zxClockSsmSendTable are created and deleted using the zxClockSsmSendRowStatus object. When create the zxAnClockSsmSendTable, zxAnClockSsmSendShelf, zxAnClockSsmSendSlot,zxAnClockSsmSendPort, zxAnClockSsmSendBytes must be setted together.Only support Pon and SyncE port.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnClockSsmSendEntry  

zxAnClockSsmSendId 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.1
ssm send id
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

zxAnClockSsmSendShelf 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.2
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnClockSsmSendSlot 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.3
Tis object indicates the slot number. In IEC19Shelf type ,value 21,22 are not supported.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnClockSsmSendPort 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.4
Tis object indicates the port number. 1-4 is used for uplink card. 1-8 is used for pon card
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..8  

zxAnClockSsmSendBytes 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.5
This attribute defines the SSM sent bytes. Only support 0,2,4,8,11,15.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..15  

zxAnClockSsmSendRowStatus 1.3.6.1.4.1.3902.1082.120.10.2.2.1.1.50
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). In particular, a newly created row cannot be created until the corresponding zxAnClockSsmSendShelf and zxAnClockSsmSendSlot and zxAnClockSsmSendPort and zxAnClockSsmSendBytes have been set.The port-type must be syncE or Pon. To delete a row in this table, a manager must set this object to destroy(6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnClockEsmcTable 1.3.6.1.4.1.3902.1082.120.10.2.2.2
This managed entity represents the ESMC(Ethernet Synchronization Messaging Channel).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnClockEsmcEntry

zxAnClockEsmcEntry 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1
It is entry in the zxClockEsmcTable. Entries in the zxClockEsmcTable are created and deleted using the zxClockEsmcRowStatus object. When create the zxAnClockEsmcTable, zxAnClockEsmcShelf, zxAnClockEsmcSlot,zxAnClockEsmcPort, zxAnClockSsmSendBytes must be setted together.Only support Pon and SyncE port.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnClockEsmcEntry  

zxAnClockEsmcId 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1.1
This object indicates clock ESMC recoder id.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..255  

zxAnClockEsmcShelf 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1.2
This object indicates the shelf number.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1  

zxAnClockEsmcSlot 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1.3
This object indicates the slot number. In IEC19Shelf type ,value 21,22 are not supported.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..22  

zxAnClockEsmcPort 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1.4
This object indicates the port number. 1-4 is used for uplink card. 1-8 is used for pon card.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..8  

zxAnClockEsmcRowStatus 1.3.6.1.4.1.3902.1082.120.10.2.2.2.1.50
The status of this conceptual row. To create a row in this table, a manager must set this object to createAndGo(4). In particular, a newly created row cannot be created until the corresponding zxAnClockEsmcShelf and zxAnClockEsmcSlot and zxAnClockEsmcPort and have been set.The port-type must be syncE or Pon. To delete a row in this table, a manager must set this object to destroy(6).
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

zxAnClockCardClockConfTable 1.3.6.1.4.1.3902.1082.120.10.2.3.2
The card clock configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ZxAnClockCardClockConfEntry

zxAnClockCardClockConfEntry 1.3.6.1.4.1.3902.1082.120.10.2.3.2.1
The card clock configuration entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  ZxAnClockCardClockConfEntry  

zxAnClockCardClockConfRack 1.3.6.1.4.1.3902.1082.120.10.2.3.2.1.1
The rack number of the card.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

zxAnClockCardClockConfShelf 1.3.6.1.4.1.3902.1082.120.10.2.3.2.1.2
The shelf number of the card.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1  

zxAnClockCardClockConfSlot 1.3.6.1.4.1.3902.1082.120.10.2.3.2.1.3
The slot number of the card.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..48  

zxAnClockCardClockConfType 1.3.6.1.4.1.3902.1082.120.10.2.3.2.1.4
The card clock configuration type. There are two types: systemClock(1): it means the card clock type is the system clock. localClock(2): it means the card clock type is the local clock.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER systemClock(1), localClock(2)  

zxAnClockSrcSwitch 1.3.6.1.4.1.3902.1082.120.10.3.1.1
for clock source switch incident report. reason:1-Abnormal,2-S1Changed,...; OldInfo:active clock source identify before switch; NewInfo:active clock source identify after switch;
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockStatusChanged 1.3.6.1.4.1.3902.1082.120.10.3.1.2
A zxAnClockStatusChanged trap is sent when the agent has detected that the current clock status has been changed to another new clock status.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockEFDAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.21
Exceeded frequency deviation alarm of clock signal Generate notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockEFDClr 1.3.6.1.4.1.3902.1082.120.10.3.1.22
Clear Exceeded frequency deviation alarm of clock signal. when the clock signal is normal,the alarm is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockNoClkAvailableAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.23
no available clock source in OLT.Generate notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockNoClkAvailableClr 1.3.6.1.4.1.3902.1082.120.10.3.1.24
Clear no available clock source alarm in OLT. when an available clock source occoured, the alarm is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLosLofAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.25
Los Lof alarm of clock signal.Generate notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLosLofClr 1.3.6.1.4.1.3902.1082.120.10.3.1.26
Clear Los Lof alarm of clock signal.. when the clock signal is normal, the alarm is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLockOutAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.27
clock signal is setted lockout.Generate notification. not supported. need further study
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLockOutClr 1.3.6.1.4.1.3902.1082.120.10.3.1.28
Clear lockout alarm of clock signal. when the clock signal is clear lockout configure, alarm is restored. not supported. need further study
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockQlFailAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.29
Ql Fail alarm of clock signal.Generate notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockQlFailClr 1.3.6.1.4.1.3902.1082.120.10.3.1.30
Clear Ql Fail alarm of clock signal.. when the QL-level is available, alarm is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLosEsmcAlm 1.3.6.1.4.1.3902.1082.120.10.3.1.31
Loss of ESMC alarm of clock signal.Generate notification.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockLosEsmcClr 1.3.6.1.4.1.3902.1082.120.10.3.1.32
Loss of ESMC alarm of clock signal.. when the ESMC normal, alarm is restored.
Status: current Access: read-write
NOTIFICATION-TYPE    

zxAnClockCompliances 1.3.6.1.4.1.3902.1082.120.10.4.1
OBJECT IDENTIFIER    

zxAnClockGroups 1.3.6.1.4.1.3902.1082.120.10.4.2
OBJECT IDENTIFIER    

zxAnClockCompliance 1.3.6.1.4.1.3902.1082.120.10.4.1.1
The compliance statement for entities which implement the ZTE-AN-CLOCK-MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

zxAnClockGlobalGroup 1.3.6.1.4.1.3902.1082.120.10.4.2.1
A collection of global objects providing clock functions
Status: current Access: read-write
OBJECT-GROUP    

zxAnClockSrcGroup 1.3.6.1.4.1.3902.1082.120.10.4.2.2
A collection of objects providing clock source configure functions
Status: current Access: read-write
OBJECT-GROUP    

zxAnClockSsmGroup 1.3.6.1.4.1.3902.1082.120.10.4.2.3
A collection of objects providing Esmc&SsmSend functions
Status: current Access: read-write
OBJECT-GROUP    

zxAnClockAlarmTrapGroup 1.3.6.1.4.1.3902.1082.120.10.4.2.4
A collection of objects providing clock alarm functions
Status: current Access: read-write
NOTIFICATION-GROUP