X25-OPT-MIB

File: X25-OPT-MIB.mib (86967 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

Counter Gauge enterprises
OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

Counter16  
INTEGER 0..65535    

Cdx6500PPCTX25PortEntry  
SEQUENCE    
  cdx6500X25CfgPortNumber INTEGER
  cdx6500X25CfgConnType INTEGER
  cdx6500X25CfgPortCont DisplayString
  cdx6500X25CfgClockSource INTEGER
  cdx6500X25CfgClockSpeed INTEGER
  cdx6500X25CfgAdmnInterfaceMode INTEGER
  cdx6500X25CfgAdmnNumberPVCs INTEGER
  cdx6500X25CfgStartPVCChanNum INTEGER
  cdx6500X25CfgNumberSVCs INTEGER
  cdx6500X25CfgStartSVCChanNum INTEGER
  cdx6500X25CfgInitFrame DisplayString
  cdx6500X25CfgT1RetryTimer INTEGER
  cdx6500X25CfgT4PollTimer INTEGER
  cdx6500X25CfgN2TransTries INTEGER
  cdx6500X25CfgFrameSeqCounting INTEGER
  cdx6500X25CfgKFrameWindow INTEGER
  cdx6500X25CfgAdmnPacketSequencing INTEGER
  cdx6500X25CfgWPacketWindow INTEGER
  cdx6500X25CfgPPacketSize INTEGER
  cdx6500X25CfgMaxNegotPacketSize INTEGER
  cdx6500X25CfgDataQueueUpper INTEGER
  cdx6500X25CfgDataQueueLower INTEGER
  cdx6500X25CfgAdmnRestartTimer INTEGER
  cdx6500X25CfgAdmnResetTimer INTEGER
  cdx6500X25CfgAdmnCallTimer INTEGER
  cdx6500X25CfgAdmnClearTimer INTEGER
  cdx6500X25CfgOutDelFacilities DisplayString
  cdx6500X25CfgOutAddFacilities DisplayString
  cdx6500X25CfgOutBarFacilities DisplayString
  cdx6500X25CfgInBarFacilities DisplayString
  cdx6500X25CfgOptions DisplayString
  cdx6500X25CfgNumRoutDigits INTEGER
  cdx6500X25CfgPortDigitsToStrip INTEGER
  cdx6500X25CfgInDigitsToStrip INTEGER
  cdx6500X25CfgRestrictConn DisplayString
  cdx6500X25CfgPortAddress DisplayString
  cdx6500X25CfgCUGMember DisplayString
  cdx6500X25CfgBillRec INTEGER
  cdx6500X25CfgSubAddrSize INTEGER
  cdx6500X25CfgIdleDiscTimer INTEGER
  cdx6500X25CfgCallSecurity INTEGER
  cdx6500X25CfgProtectLevel INTEGER
  cdx6500X25CfgReconnTimeout INTEGER
  cdx6500X25CfgReconnTriesLimit INTEGER
  cdx6500X25CfgFacilSubscripCont DisplayString
  cdx6500X25CfgAlarmPriority INTEGER
  cdx6500X25CfgAddrTrans DisplayString
  cdx6500X25CfgNumberInSVCs INTEGER
  cdx6500X25CfgStartInSVCChanNum INTEGER
  cdx6500X25CfgNumberOutSVCs INTEGER
  cdx6500X25CfgStartOutSVCChanNum INTEGER
  cdx6500X25CfgChargeInfoReq INTEGER
  cdx6500X25CfgVerfnTimer INTEGER
  cdx6500X25CfgValdFailures INTEGER
  cdx6500X25CfgActionType INTEGER
  cdx6500X25CfgLineIdleMode INTEGER
  cdx6500X25CfgConfOption DisplayString
  cdx6500X25CfgInvertTxClk INTEGER
  cdx6500X25CfgDimType INTEGER
  cdx6500X25CfgMoreOptions DisplayString
  cdx6500X25CfgPsfFlag INTEGER
  cdx6500X25CfgElectricalInterfaceType INTEGER
  cdx6500X25CfgV24ElectricalInterfaceOption INTEGER
  cdx6500X25CfgHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTX25PortEntry  
SEQUENCE    
  cdx6500X25StatPortNumber INTEGER
  cdx6500X25StatPortStatus DisplayString
  cdx6500X25StatPortState INTEGER
  cdx6500X25StatActualPortSpeed INTEGER
  cdx6500X25StatPortUtilIn INTEGER
  cdx6500X25StatPortUtilOut INTEGER
  cdx6500X25StatMaxSVCCount Gauge
  cdx6500X25StatCurrSVCCount INTEGER
  cdx6500X25StatInChars Counter
  cdx6500X25StatOutChars Counter
  cdx6500X25StatInPkts Counter
  cdx6500X25StatOutPkts Counter
  cdx6500X25StatInDataFrames Counter
  cdx6500X25StatOutDataFrames Counter
  cdx6500X25StatNumPktsQueued INTEGER
  cdx6500X25StatCharRateIn INTEGER
  cdx6500X25StatCharRateOut INTEGER
  cdx6500X25StatPktRateIn INTEGER
  cdx6500X25StatPktRateOut INTEGER
  cdx6500X25StatFrameRateIn INTEGER
  cdx6500X25StatFrameRateOut INTEGER
  cdx6500X25StatOverrunErrs Counter16
  cdx6500X25StatUnderrunErrs Counter16
  cdx6500X25StatCRCErrs Counter16
  cdx6500X25StatInInfoFrames Counter
  cdx6500X25StatOutInfoFrames Counter
  cdx6500X25StatInRNRFrames Counter
  cdx6500X25StatOutRNRFrames Counter
  cdx6500X25StatInRRFrames Counter
  cdx6500X25StatOutRRFrames Counter
  cdx6500X25StatInREJFrames Counter
  cdx6500X25StatOutREJFrames Counter
  cdx6500X25StatInDataPkts Counter
  cdx6500X25StatOutDataPkts Counter
  cdx6500X25StatNumRxCallsSinceLastReset INTEGER
  cdx6500X25StatNumRxCallsRejected INTEGER
  cdx6500X25StatRxLastCallFailureCause INTEGER
  cdx6500X25StatRxLastCalledNumber DisplayString
  cdx6500X25StatRxLastCallingNumber DisplayString
  cdx6500X25StatRxMinCallDuration DisplayString
  cdx6500X25StatRxMaxCallDuration DisplayString
  cdx6500X25StatRxAvgCallDuration DisplayString
  cdx6500X25StatNumTxCallsSinceLastReset INTEGER
  cdx6500X25StatNumTxCallsRejected INTEGER
  cdx6500X25StatTxLastCallFailureCause INTEGER
  cdx6500X25StatTxLastCalledNumber DisplayString
  cdx6500X25StatTxLastCallingNumber DisplayString
  cdx6500X25StatTxMinCallDuration DisplayString
  cdx6500X25StatTxMaxCallDuration DisplayString
  cdx6500X25StatTxAvgCallDuration DisplayString
  cdx6500X25StatSignalingState INTEGER
  cdx6500X25StatMaxPortUtilIn INTEGER
  cdx6500X25StatMaxPortUtilOut INTEGER
  cdx6500X25StatMaxPortUtilInTime DisplayString
  cdx6500X25StatMaxPortUtilOutTime DisplayString
  cdx6500X25StatMaxSVCCountTime DisplayString

Cdx6500CGTInboundCallTranEntry  
SEQUENCE    
  cdx6500InCallTranEntryNum INTEGER
  cdx6500InCallTranInSubAddr DisplayString
  cdx6500InCallTranPrivNetAddr DisplayString

Cdx6500CGTOutboundCallTranEntry  
SEQUENCE    
  cdx6500OutCallTranEntryNum INTEGER
  cdx6500OutCallTranPrivNetAddr DisplayString
  cdx6500OutCallTranOutNetAddr DisplayString
  cdx6500OutCallTranOptions INTEGER

Cdx6500CGTCallingAddrTranEntry  
SEQUENCE    
  cdx6500CalladdrtranEntryNum INTEGER
  cdx6500CalladdrtranInCallAddr DisplayString
  cdx6500CalladdrtranPrivNetAddr DisplayString

Cdx6500CGTCudBaseAddrTranEntry  
SEQUENCE    
  cdx6500CudBaseaddrtranEntryNum INTEGER
  cdx6500CudBaseStr DisplayString
  cdx6500CudBaseAddr DisplayString

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500CfgGeneralGroup 1.3.6.1.4.1.449.2.1.2.2
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PPCTX25PortTable 1.3.6.1.4.1.449.2.1.2.1.1.2
A table of X.25 Port configuration entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTX25PortEntry

cdx6500PPCTX25PortEntry 1.3.6.1.4.1.449.2.1.2.1.1.2.1
An X.25 Configuration Table entry. Each entry contains the configuration parameters for a single X.25 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTX25PortEntry  

cdx6500X25CfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.2.1.1
Port number for this X.25 port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500X25CfgConnType 1.3.6.1.4.1.449.2.1.2.1.1.2.1.2
Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. dtr - dedicated, require the data terminal ready signal (DTR). dtrd - same as DTR, except data set ready (DSR) drops between calls. dimo - port handshakes with attached dial modem dimoa - same as DIMO except DSR never raised on incoming call from modem. dimob - same as DIMO except DSR follows DTR on incoming call from modem. dimov - port handshakes with attached V.25 bis dial modem. emri - port emulates a dial modem with ring indicator (RI). emdc - port emulates a dial modem with data carrier detect (DCD). simpv - SIMP/DIMOv, modem will switch from Leased to Dial-only mode when leased line goes down (used with Link Backup only). simpb - simple, no control signals required for data transmission and reception. By default output leads will be low.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER simp(1), dtr(2), dtrd(3), emri(4), emdc(5), dimo(6), dimoa(7), dimob(8), dimov(11), simpv(12), simpb(21)  

cdx6500X25CfgPortCont 1.3.6.1.4.1.449.2.1.2.1.1.2.1.3
Specify any of the following port control options: NONE - no option specified. MB - raise Pin 22 when the port becomes disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(2..7)  

cdx6500X25CfgClockSource 1.3.6.1.4.1.449.2.1.2.1.1.2.1.4
int - internal clock source. ext - external clock source. extint - internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). extlp must be configured in conjunction with extint.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER int(1), ext(2), extint(3), extlp(4)  

cdx6500X25CfgClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.2.1.5
This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependant on the card type, and on the interface type. See the 6500 Series Configuration and Administration Manual for proper values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1200..384000  

cdx6500X25CfgAdmnInterfaceMode 1.3.6.1.4.1.449.2.1.2.1.1.2.1.6
The logical link address must be set to complementary values in devices at each end of the link: dte - link to have logical DTE address (A). dce - link to have logical DCE address (B). negotiate - link ends will negotiate which end is DCE address (B). This option is available only if the correct CSK is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2), negotiate(3)  

cdx6500X25CfgAdmnNumberPVCs 1.3.6.1.4.1.449.2.1.2.1.1.2.1.7
Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..128  

cdx6500X25CfgStartPVCChanNum 1.3.6.1.4.1.449.2.1.2.1.1.2.1.8
This is the starting logical channel number for the Permanent Virtual Circuits on this link. Not used if the number of PVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgNumberSVCs 1.3.6.1.4.1.449.2.1.2.1.1.2.1.9
Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a link should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..512  

cdx6500X25CfgStartSVCChanNum 1.3.6.1.4.1.449.2.1.2.1.1.2.1.10
This is the starting logical channel number for the Switched Virtual Circuits on this link. Not used if the number of SVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgInitFrame 1.3.6.1.4.1.449.2.1.2.1.1.2.1.11
Specify the initial frame required by other end for link startup: none - do nothing (other end initiates link-up). sabm - send SABM. disc - send DISC, then SABM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sabm(1), disc(2), none(3)  

cdx6500X25CfgT1RetryTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.12
T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

cdx6500X25CfgT4PollTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.13
This sets the time an idle link is probed for assurance of connection to the remote device. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500X25CfgN2TransTries 1.3.6.1.4.1.449.2.1.2.1.1.2.1.14
The maximum number of attempts allowed to complete a transmission.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..20  

cdx6500X25CfgFrameSeqCounting 1.3.6.1.4.1.449.2.1.2.1.1.2.1.15
Port uses normal or extended frame sequence numbering norm - normal sequence counting (Modulo 8). ext - extended sequencing (Modulo 128).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), ext(2)  

cdx6500X25CfgKFrameWindow 1.3.6.1.4.1.449.2.1.2.1.1.2.1.16
Frame level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

cdx6500X25CfgAdmnPacketSequencing 1.3.6.1.4.1.449.2.1.2.1.1.2.1.17
Port uses normal or extended packet level sequence numbers : norm - normal sequencing (Modulo 8). ext - extended sequencing (Modulo 128). The value must be the same in devices at each end of the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), ext(2)  

cdx6500X25CfgWPacketWindow 1.3.6.1.4.1.449.2.1.2.1.1.2.1.18
Packet level window size must be set to the same value in devices at each end of the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..63  

cdx6500X25CfgPPacketSize 1.3.6.1.4.1.449.2.1.2.1.1.2.1.19
This is the maximum packet size used on X.25 links. For proper operation, the size must be the same in devices at each end of the link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bytes128(7), bytes256(8), bytes512(9), bytes1024(10)  

cdx6500X25CfgMaxNegotPacketSize 1.3.6.1.4.1.449.2.1.2.1.1.2.1.20
This is the maximum negotiated packet size allowed for inbound and outbound calls on this X.25 link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bytes128(7), bytes256(8), bytes512(9), bytes1024(10)  

cdx6500X25CfgDataQueueUpper 1.3.6.1.4.1.449.2.1.2.1.1.2.1.21
This is the maximum number of data packets a channel on this port will queue for transmission before invoking flow control to the attached channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

cdx6500X25CfgDataQueueLower 1.3.6.1.4.1.449.2.1.2.1.1.2.1.22
This is the number of data packets a channel on this port will have queued for transmission when it releases flow control to the attached channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..63  

cdx6500X25CfgAdmnRestartTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.23
Restart-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500X25CfgAdmnResetTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.24
Reset-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..180  

cdx6500X25CfgAdmnCallTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.25
Call-Request timeout timer in seconds. If timer expires, call is cleared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500X25CfgAdmnClearTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.26
Clear-Request timeout timer in seconds. If timer expires, request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500X25CfgOutDelFacilities 1.3.6.1.4.1.449.2.1.2.1.1.2.1.27
Specify facilities deleted from an outbound call before it is forwarded: NONE - no facilities deleted. THRO - delete throughput class negotiation. NUI - delete network user identification. CUG - delete closed user group. Any combination of above specified by summing (e.g. THRO+NUI. . .).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..17)  

cdx6500X25CfgOutAddFacilities 1.3.6.1.4.1.449.2.1.2.1.1.2.1.28
Specify facilities added to an outbound call before it is forwarded: NONE - no facilities added. REV - add reverse charging. PACK - add packet size negotiation. WIND - add window size negotiation. Any combination of above specified by summing (e.g. PACK+WIND+. . .).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..18)  

cdx6500X25CfgOutBarFacilities 1.3.6.1.4.1.449.2.1.2.1.1.2.1.29
Specify facilities which, if present in an outbound call will be blocked by the port: NONE - no facility blocked. REV - bar reverse charging. FAST - bar fast select. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. Any combination of above specified by summing (e.g. REV+FAST).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..24)  

cdx6500X25CfgInBarFacilities 1.3.6.1.4.1.449.2.1.2.1.1.2.1.30
Specify facilities which, if present in an inbound call, will be blocked by the port: NONE - no facility blocked. BCUG - bar Bilateral Closed User Group. DGRAM - bar datagram. REV - bar Reverse Charging. Any combination of above specified by summing (e.g. DGRAM+BCUG).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..19)  

cdx6500X25CfgOptions 1.3.6.1.4.1.449.2.1.2.1.1.2.1.31
Select options on this X.25 port as follows: NONE - no option specified. 1980 - use X.25 1980. NUI - perform network user identification validation check. PDN - connected to Public Data Network. CUD - use call user data subaddressing. IBAR - bar all calls coming in from X.25 port user. OBAR - bar all calls going out to X.25 port user. CBCK - allow routing inbound calls back out this port. CUG - check closed user group; otherwise, CUG passes transparently. CAUSE - pass cause, diagnostic, code in outbound packets. HOLD - hold calls over link restart. NRST - do not send restart packet on link-up. BKUP - this is a backup port to be activated if other ports are down. INL - inter-node link. Link goes to another Vanguard device.INL may be a poor choice for high speed links.INLB is set with INL to improve the performance of high speed links.INLB can be configured in the More X25 Options parameter. INLA - set with INL option when an X.25 link connection is to a 6500 node using 2.12.04 or earlier. DELAY - enable Delay and Path trace on this link (link must connected to Rel. 4.xx node). Any combination of above specified by summing (e.g. 1980+NUI+. . .).
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..107)  

cdx6500X25CfgNumRoutDigits 1.3.6.1.4.1.449.2.1.2.1.1.2.1.32
This specifies the number of routing digits in the call user data. It is used on X.25 links attached to a Public Data Network where the private network address is carried in the call user data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..12  

cdx6500X25CfgPortDigitsToStrip 1.3.6.1.4.1.449.2.1.2.1.1.2.1.33
For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the called address before forwarding the call to the PDN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..14  

cdx6500X25CfgInDigitsToStrip 1.3.6.1.4.1.449.2.1.2.1.1.2.1.34
For X.25 links connected to a Public Data Network, this parameter specifies the number of prefix digits to remove from the incoming calling address before forwarding the call from the PDN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500X25CfgRestrictConn 1.3.6.1.4.1.449.2.1.2.1.1.2.1.35
All calls entering this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. Blank this field to disable this function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

cdx6500X25CfgPortAddress 1.3.6.1.4.1.449.2.1.2.1.1.2.1.36
On X.25 links: If the X.25 Option REGO or REGI is selected, this address is inserted into the calling address field of the outbound or inbound call packet. On MUX links: When a MUX channel makes a call, the subaddress of the channel is appended to this address and inserted into the calling address field of the call packet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500X25CfgCUGMember 1.3.6.1.4.1.449.2.1.2.1.1.2.1.37
The port may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number (except `--') and separated by a comma. ( e.g. 12,34,56,09,02,03 ). `--' - No CUG Membership. 00-99 - CUG Membership.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..23)  

cdx6500X25CfgBillRec 1.3.6.1.4.1.449.2.1.2.1.1.2.1.38
This controls whether billing (accounting) records will be created for calls on this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

cdx6500X25CfgSubAddrSize 1.3.6.1.4.1.449.2.1.2.1.1.2.1.39
For ports connected to a Public Data Network, this parameter specifies the number of digits in the subaddress of an X.25 address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3  

cdx6500X25CfgIdleDiscTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.40
The time in seconds that the port must be idle (no calls) before being automatically disconnected. A value of 0 disables the Idle Disconnect feature. This feature may only be enabled on DIMO/DIMOa/DIMOb/DIMOv/SIMPv ports with the BKUP option selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..3200  

cdx6500X25CfgCallSecurity 1.3.6.1.4.1.449.2.1.2.1.1.2.1.41
For ports used as V.25 bis backup, this parameter specifies the type of call security to use prior to the link being detected up : disable - Disable will allow both incoming and outgoing calls. enable - Enable will allow ONLY outgoing calls. Incoming calls will be immediately terminated. This parameter is only used with Link Backup.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

cdx6500X25CfgProtectLevel 1.3.6.1.4.1.449.2.1.2.1.1.2.1.42
This specifies the level of data or connection protection which will be applied to calls to or from this port. The actual level for a call will be negotiated to the lesser of this level and the level configured for the other end of the call : none - No protection. cpOnly - Connection protection only. fullDcp - Full data and connection protection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), cpOnly(2), fullDcp(3)  

cdx6500X25CfgReconnTimeout 1.3.6.1.4.1.449.2.1.2.1.1.2.1.43
This specifies the number of seconds that DCP on the originating side will wait between reconnection attempts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..128  

cdx6500X25CfgReconnTriesLimit 1.3.6.1.4.1.449.2.1.2.1.1.2.1.44
This specifies the number of times that DCP on the originating side will attempt to reconnect before clearing the call. If 0 is entered, it will not attempt to reconnect.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..127  

cdx6500X25CfgFacilSubscripCont 1.3.6.1.4.1.449.2.1.2.1.1.2.1.45
NONE - Subscription to facilities not enforced. FCN-ON - Flow Control Negotiation enabled. Packet and Window size negotiation facilities in an inbound call will be allowed. Packet and Window size facilities will always be included in outbound calls and call accepted/ connected when this parameter is set. FCN-OFF - Flow Control Negotiation disabled. Inbound calls containing Packet and Window size facilities will be cleared. Packet and Window size facilities will not be present in outbound calls and call accepted/ connected when this parameter is set. TCN-ON - Throughput Class Negotiation enabled. The throughput class negotiation facility in an inbound call will be allowed. The throughput class negotiation facility will always be included in outbound calls and call accepted/connected when this parameter is set. The facility is passed onward to the destination in the call packet transparently and does not alter the handling of the SVC data within the node. TCN-OFF - Throughput Class Negotiation disabled. Inbound calls containing the throughput class negotiation facility will be cleared. The throughput class negotiation facility will not be present in outbound calls and call accepted/connected when this parameter is set. Some combinations of above options are allowed (e.g. FCN-ON+TCN-ON).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4..34)  

cdx6500X25CfgAlarmPriority 1.3.6.1.4.1.449.2.1.2.1.1.2.1.46
Specify the severity level of LINK UP and LINK DOWN alarms : network - Severity HIGH alarms will be generated. access - Severity LOW alarms will be generated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER network(1), access(2)  

cdx6500X25CfgAddrTrans 1.3.6.1.4.1.449.2.1.2.1.1.2.1.47
Select any of the following address translation options NONE - no option specified Outbound Call Processing: DEDO - delete called address. DEGO - delete calling address. REGO - replace calling address with configured Port Address. REGSO - replace calling address with configured Port Address plus Inbound Subaddress obtained from the Inbound Call Translation Table entry where Private Network Address matches the entire calling address. INGO - replace calling address with configured Port Address and retain original calling subaddress. SAGO - strip calling address, but retain subaddress. Inbound Call Processing: INGI - replace calling address with configured Port Address and retain original calling subaddress. REGI - replace calling address with configured Port Address. SRGI - select route from the Calling Address Translation Table by replacing the called address with the Private Network Address where the Inbound Calling Address matches the beginning of the calling address. Call Accept Processing: DADA - delete called address in inbound/outbound call accept. DAGA - delete calling address in inbound/outbound call accept. IADD - copy called and calling addresses from call request into outbound call accepted/connected. Some of the options may be combined (e.g. DEDO+DEGO+...)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(3..107)  

cdx6500X25CfgNumberInSVCs 1.3.6.1.4.1.449.2.1.2.1.1.2.1.48
Number of logical channels used in One Way Incoming Switched Virtual Circuits. The total number of PVC, One Way Incoming, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgStartInSVCChanNum 1.3.6.1.4.1.449.2.1.2.1.1.2.1.49
This is the starting logical channel number for the One Way Incoming Switched Virtual Circuits on this link. Not used if the number of One Way Incoming SVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgNumberOutSVCs 1.3.6.1.4.1.449.2.1.2.1.1.2.1.50
Number of logical channels used in One Way Outgoing Switched Virtual Circuits. The total number of PVC, One Way Outgoing, One Way Outgoing and Two Way SVC channels should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgStartOutSVCChanNum 1.3.6.1.4.1.449.2.1.2.1.1.2.1.51
This is the starting logical channel number for the One Way Outgoing Switched Virtual Circuits on this link. Not used if the number of One Way Outgoing SVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..4095  

cdx6500X25CfgChargeInfoReq 1.3.6.1.4.1.449.2.1.2.1.1.2.1.52
This parameter specifies whether Charging Information has to be sent even without requesting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cdx6500X25CfgVerfnTimer 1.3.6.1.4.1.449.2.1.2.1.1.2.1.53
Specify the NUI verification timer in seconds. The call is cleared if timer expires.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..180  

cdx6500X25CfgValdFailures 1.3.6.1.4.1.449.2.1.2.1.1.2.1.54
The maximum number of successive NUI verification failures an X.25 DTE can tolerate when making verification attempts timer expires.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500X25CfgActionType 1.3.6.1.4.1.449.2.1.2.1.1.2.1.55
This specifies the course of action to be taken if the NUI violations exceed the configured threshold count. This parameter is effective only if the X25 options parameter is set to CNUI NONE - No action is taken. DISC - All connections on the port are broken. DEGR - Port is busied-out for one minute then it is re-enabled. LOCK - All connections on the port are broken and the port is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), disc(2), degr(3), lock(4)  

cdx6500X25CfgLineIdleMode 1.3.6.1.4.1.449.2.1.2.1.1.2.1.56
Specify any of the following line idle mode options: FLAG - Flag fill between frames MARK - Mark idle between frames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER flag(1), mark(2)  

cdx6500X25CfgConfOption 1.3.6.1.4.1.449.2.1.2.1.1.2.1.57
Select any of the following conformance control options: NONE - no option specified CHKFAC - Checking of facility codes enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..34)  

cdx6500X25CfgInvertTxClk 1.3.6.1.4.1.449.2.1.2.1.1.2.1.58
This parameter specifies whether the phase of the transmit clock should be inverted. NO - Don't invert YES - Invert
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

cdx6500X25CfgDimType 1.3.6.1.4.1.449.2.1.2.1.1.2.1.59
Specify the physical interface type to be used for this port: V.36 - V.36 physical interface EIA-530A - EIA-530A physical interface V.35 - V.35 physical interface X.21 - X.21 physical interface RS-449 - RS-449 physical interface EIA-530 - EIA-530 physical interface RS-232 - RS-232 physical interface
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dim-type-none(1), dim-type-not-installed(2), dim-type-eia-232-d(3), dim-type-x21(4), dim-type-v35(5), dim-type-v36(6), dim-type-v11(7), dim-type-eia-530(8), dim-type-dsu(9), dim-type-isdn(10), dim-type-vrdc(11), dim-type-i430(12), dim-type-vrdc-2fxs(13), dim-type-t1e1(14), dim-type-future-use(15), dim-not-supported(16), dim-type-vrdc-2em(17), dim-type-vrdc-bri(18)  

cdx6500X25CfgMoreOptions 1.3.6.1.4.1.449.2.1.2.1.1.2.1.60
Select more options on this X.25 port as follows: NONE - no option specified INLB - set with INL option to improve performance if inter-node link is a high speed link
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(4..9)  

cdx6500X25CfgPsfFlag 1.3.6.1.4.1.449.2.1.2.1.1.2.1.61
Enable or Disable Port Selection Facility feature. Used to control access to ports for Select user group applications.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER psf-disabled(1), psf-enabled(2)  

cdx6500X25CfgElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.2.1.62
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500X25CfgV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.2.1.63
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500X25CfgHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.2.1.64
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTX25PortTable 1.3.6.1.4.1.449.2.1.3.1.1.2
A table of X.25 Port statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTX25PortEntry

cdx6500PPSTX25PortEntry 1.3.6.1.4.1.449.2.1.3.1.1.2.1
An X.25 Statistics Table entry. Each entry contains the statistics for a single X.25 port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTX25PortEntry  

cdx6500X25StatPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.2.1.1
The port number for this X.25 port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500X25StatPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.2.1.2
Status of this port : Up - Port is active Down - Port Is inactive Disabled - An operator has disabled the port Busy Out - an operator has busied out the port
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(2..8)  

cdx6500X25StatPortState 1.3.6.1.4.1.449.2.1.3.1.1.2.1.3
discPhase - Disconnect Phase. linkDisk - Link Disconnect. linkSetup - The port is sending SABM frames and waiting for a UA response. sabmColl - SABM Collision. frameReject - The port has rejected a received frame. normal - The port sending/receiving data. remoteBusy - The port is receiving RNR frames. reset - The port is being reset. sendRej - The port is sending REJ frames. rbSr - The port is receiving RNR frames and sending REJ frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER discPhase(1), linkDisk(2), linkSetup(3), sabmColl(4), frameReject(5), normal(6), remoteBusy(7), reset(8), sendReject(9), rbSr(10)  

cdx6500X25StatActualPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.2.1.4
This is the speed of the port when Clock = INT; this is the detected clock speed if Clock = EXT. If Port Speed is 0, Clock = EXT, but clocking is not being received fom attatched device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatPortUtilIn 1.3.6.1.4.1.449.2.1.3.1.1.2.1.5
Percentage of port bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500X25StatPortUtilOut 1.3.6.1.4.1.449.2.1.3.1.1.2.1.6
Percentage of port bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500X25StatMaxSVCCount 1.3.6.1.4.1.449.2.1.3.1.1.2.1.7
Maximum number of SVCs in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

cdx6500X25StatCurrSVCCount 1.3.6.1.4.1.449.2.1.3.1.1.2.1.8
Current number of SVCs in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500X25StatInChars 1.3.6.1.4.1.449.2.1.3.1.1.2.1.9
Number of characters received since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutChars 1.3.6.1.4.1.449.2.1.3.1.1.2.1.10
Number of characters sent since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInPkts 1.3.6.1.4.1.449.2.1.3.1.1.2.1.11
Number of packets received since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutPkts 1.3.6.1.4.1.449.2.1.3.1.1.2.1.12
Number of packets sent since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInDataFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.13
Number of frames received since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutDataFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.14
Number of frames sent since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatNumPktsQueued 1.3.6.1.4.1.449.2.1.3.1.1.2.1.15
Number of packets currently queued.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatCharRateIn 1.3.6.1.4.1.449.2.1.3.1.1.2.1.16
Summary of the characters being received by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatCharRateOut 1.3.6.1.4.1.449.2.1.3.1.1.2.1.17
Summary of the characters being sent by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatPktRateIn 1.3.6.1.4.1.449.2.1.3.1.1.2.1.18
Summary of the packets being received by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatPktRateOut 1.3.6.1.4.1.449.2.1.3.1.1.2.1.19
Summary of the packets being sent by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatFrameRateIn 1.3.6.1.4.1.449.2.1.3.1.1.2.1.20
Summary of the frames being received by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatFrameRateOut 1.3.6.1.4.1.449.2.1.3.1.1.2.1.21
Summary of the frames being sent by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatOverrunErrs 1.3.6.1.4.1.449.2.1.3.1.1.2.1.22
Number of Overrun errors since the last node or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500X25StatUnderrunErrs 1.3.6.1.4.1.449.2.1.3.1.1.2.1.23
Number of Underrun errors since the last node or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500X25StatCRCErrs 1.3.6.1.4.1.449.2.1.3.1.1.2.1.24
Number of CRC errors since the last node or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500X25StatInInfoFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.25
Number of Info frames received since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutInfoFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.26
Number of Info frames sent since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInRNRFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.27
Number of frames received since last node, port or statistics reset indicating RNR.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutRNRFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.28
Number of frames sent since last node, port or statistics reset indicating RNR.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInRRFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.29
Number of frames received since last node, port or statistics reset indicating RR.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutRRFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.30
Number of frames sent since last node, port or statistics reset indicating RR.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInREJFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.31
Number of frames received since last node, port or statistics reset indicating REJ.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutREJFrames 1.3.6.1.4.1.449.2.1.3.1.1.2.1.32
Number of frames sent since last node, port or statistics reset indicating REJ.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatInDataPkts 1.3.6.1.4.1.449.2.1.3.1.1.2.1.33
Number of data packets received since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatOutDataPkts 1.3.6.1.4.1.449.2.1.3.1.1.2.1.34
Number of data packets sent since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500X25StatNumRxCallsSinceLastReset 1.3.6.1.4.1.449.2.1.3.1.1.2.1.35
The number of inbound calls that were attempted since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatNumRxCallsRejected 1.3.6.1.4.1.449.2.1.3.1.1.2.1.36
The number of inbound calls that were rejected since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatRxLastCallFailureCause 1.3.6.1.4.1.449.2.1.3.1.1.2.1.37
The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(100), noFailureReported(193), noAvailableVirtualPort(194), securityViolation(195), noResourcesAvailable(196), callRejected(197), invalidPhoneNumber(198), outgoingCallRequestTimeout(199), callCollision(200), virtualPortNotAvailable(201), invalidConfiguration(202), failureNotSupported(203)  

cdx6500X25StatRxLastCalledNumber 1.3.6.1.4.1.449.2.1.3.1.1.2.1.38
The phone number of the virtual port of the last ISDN call made into this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500X25StatRxLastCallingNumber 1.3.6.1.4.1.449.2.1.3.1.1.2.1.39
The phone number of last party to make an ISDN call into this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500X25StatRxMinCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.40
The minimum call duration of all inbound ISDN calls made into this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatRxMaxCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.41
The maximum call duration of all inbound ISDN calls made into this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatRxAvgCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.42
The average call duration of all inbound ISDN calls made into this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatNumTxCallsSinceLastReset 1.3.6.1.4.1.449.2.1.3.1.1.2.1.43
The number of outbound calls that were attempted since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatNumTxCallsRejected 1.3.6.1.4.1.449.2.1.3.1.1.2.1.44
The number of outbound calls that were rejected since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500X25StatTxLastCallFailureCause 1.3.6.1.4.1.449.2.1.3.1.1.2.1.45
The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: notAvailable : Value not available if not a (virtual) switched data port. noFailureReported : No call failure noAvailableVirtualPort : No virtual port available securityViolation : Password security failed noResourcesAvailable : No resources available callRejected : Call failed by Xircom card invalidPhoneNumber : Phone number is incorrect outgoingCallRequestTimeout : Outgoing call req timeout callCollision : Call collision virtualPortNotAvailable : This port is not available invalidConfiguration : Configuration is incorrect failureNotSupported : Failure is not supported
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(100), noFailureReported(193), noAvailableVirtualPort(194), securityViolation(195), noResourcesAvailable(196), callRejected(197), invalidPhoneNumber(198), outgoingCallRequestTimeout(199), callCollision(200), virtualPortNotAvailable(201), invalidConfiguration(202), failureNotSupported(203)  

cdx6500X25StatTxLastCalledNumber 1.3.6.1.4.1.449.2.1.3.1.1.2.1.46
The phone number of the last ISDN call made by a virtual port from this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500X25StatTxLastCallingNumber 1.3.6.1.4.1.449.2.1.3.1.1.2.1.47
The phone number of the virtual port that made the last ISDN call from this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500X25StatTxMinCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.48
The minimum call duration of all outbound ISDN calls made from this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatTxMaxCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.49
The maximum call duration of all outbound ISDN calls made from this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatTxAvgCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.2.1.50
The average call duration of all outbound ISDN calls made from this port, since the last statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatSignalingState 1.3.6.1.4.1.449.2.1.3.1.1.2.1.51
ISDN call signaling state. The possible values are: idle : No ISDN call present. ringing : Pending outgoing ISDN call request. connected : ISDN call is connected. congested : Congested mode. disabled : Virtual Port is disabled. dChannelDown : D-channel is down. disabledChannelDown : Disable and D-channel is down. disconnecting : Pending ISDN call disconnection. notAvailable : Value not available if not a (virtual) switched data port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER idle(1), ringing(2), connected(3), congested(4), disabled(5), dChannelDown(6), disabledDChannelDown(7), disconnecting(8), notAvailable(100)  

cdx6500X25StatMaxPortUtilIn 1.3.6.1.4.1.449.2.1.3.1.1.2.1.52
Max percentage of port bandwidth in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500X25StatMaxPortUtilOut 1.3.6.1.4.1.449.2.1.3.1.1.2.1.53
Max percentage of port bandwidth in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500X25StatMaxPortUtilInTime 1.3.6.1.4.1.449.2.1.3.1.1.2.1.54
Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatMaxPortUtilOutTime 1.3.6.1.4.1.449.2.1.3.1.1.2.1.55
Time stamp of Max percentage of port bandwidth in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500X25StatMaxSVCCountTime 1.3.6.1.4.1.449.2.1.3.1.1.2.1.56
Time stamp of Maximum number of SVCs in use since last node, port or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500CGTInboundCallTranTable 1.3.6.1.4.1.449.2.1.2.2.2
All of the configuration parameters relevant to the Inbound Call Translation table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CGTInboundCallTranEntry

cdx6500CGTInboundCallTranEntry 1.3.6.1.4.1.449.2.1.2.2.2.1
A row of Inbound Call Translation configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CGTInboundCallTranEntry  

cdx6500InCallTranEntryNum 1.3.6.1.4.1.449.2.1.2.2.2.1.1
This is not a configuration parameter. Instead, it identifies the particular Inbound Call Translation Table entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1000  

cdx6500InCallTranInSubAddr 1.3.6.1.4.1.449.2.1.2.2.2.1.2
This is the subaddress contained in an inbound call from another network, usually a public data network (PDN). It will be translated into a private network address before the call is forwarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500InCallTranPrivNetAddr 1.3.6.1.4.1.449.2.1.2.2.2.1.3
This is the private network address to translate to, before forwarding calls from a PDN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500CGTOutboundCallTranTable 1.3.6.1.4.1.449.2.1.2.2.3
All of the configuration parameters relevant to the Outbound Call Translation table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CGTOutboundCallTranEntry

cdx6500CGTOutboundCallTranEntry 1.3.6.1.4.1.449.2.1.2.2.3.1
A row of Outbound Call Translation configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CGTOutboundCallTranEntry  

cdx6500OutCallTranEntryNum 1.3.6.1.4.1.449.2.1.2.2.3.1.1
This is not a configuration parameter. Instead, it identifies the particular Outbound Call Translation Table entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..1600  

cdx6500OutCallTranPrivNetAddr 1.3.6.1.4.1.449.2.1.2.2.3.1.2
This is the private network address contained in an outbound call to another network, usually a public data network (PDN). It will be translated into a PDN address before the call is forwarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500OutCallTranOutNetAddr 1.3.6.1.4.1.449.2.1.2.2.3.1.3
This is the public network address to translate to, before forwarding calls to a PDN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500OutCallTranOptions 1.3.6.1.4.1.449.2.1.2.2.3.1.4
This parameter specifies options for outbound call address translation as follows: olda - insert the original called address into outbound call user data. newvalNone - same functionality as 'none', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(0), olda(1), newvalNone(50)  

cdx6500CGTCallingAddrTranTable 1.3.6.1.4.1.449.2.1.2.2.13
All of the configuration parameters relevant to the Calling AddressTranslation table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CGTCallingAddrTranEntry

cdx6500CGTCallingAddrTranEntry 1.3.6.1.4.1.449.2.1.2.2.13.1
A row of Calling Address Translation configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CGTCallingAddrTranEntry  

cdx6500CalladdrtranEntryNum 1.3.6.1.4.1.449.2.1.2.2.13.1.1
This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

cdx6500CalladdrtranInCallAddr 1.3.6.1.4.1.449.2.1.2.2.13.1.2
This is the calling address contained in an inbound call, it will be translated into a private network address (if a match is found in the Translation Table), before the call is forwarded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500CalladdrtranPrivNetAddr 1.3.6.1.4.1.449.2.1.2.2.13.1.3
This is the private network address to translate to, before forwarding the call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)  

cdx6500CGTCudBaseAddrTranTable 1.3.6.1.4.1.449.2.1.2.2.23
All of the configuration parameters relevant to the CUD Base AddressTranslation table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500CGTCudBaseAddrTranEntry

cdx6500CGTCudBaseAddrTranEntry 1.3.6.1.4.1.449.2.1.2.2.23.1
A row of CUD Base Address Translation configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500CGTCudBaseAddrTranEntry  

cdx6500CudBaseaddrtranEntryNum 1.3.6.1.4.1.449.2.1.2.2.23.1.1
This is not a configuration parameter. Instead, it identifies the entry being configured by the other parameters in the record.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..64  

cdx6500CudBaseStr 1.3.6.1.4.1.449.2.1.2.2.23.1.2
Enter the sub-string to search in the CUD for the incoming call for translating it into Called address. For searching from index in the CUD the name can be specified as (7)DADADIFUBBBB, it will skip 7 characters of the CUD and match DADAIFUBBBB in the CUD starting at Position 8.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..64)  

cdx6500CudBaseAddr 1.3.6.1.4.1.449.2.1.2.2.23.1.3
Enter the X.25 Address which will be inserted for called address of incoming X.25 call packet if the configured CUD string is matched in the CUD of the incoming X.25 Call packet.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..15)