Wellfleet-E1-MIB

File: Wellfleet-E1-MIB.mib (6522 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215
RFC1213-MIB Wellfleet-COMMON-MIB

Imported symbols

IpAddress Counter Gauge
TimeTicks Opaque enterprises
mgmt OBJECT-TYPE TRAP-TYPE
DisplayString mib-2 wfLine

Defined Types

WfE1Entry  
SEQUENCE    
  wfE1Delete INTEGER
  wfE1Disable INTEGER
  wfE1State INTEGER
  wfE1Slot INTEGER
  wfE1Connector INTEGER
  wfE1Madr OCTET STRING
  wfE1HDB3Support INTEGER
  wfE1ClockMode INTEGER
  wfE1MiniDacs DisplayString
  wfE1BipolarVios Counter
  wfE1FrameErrs Counter
  wfE1RcvRemAlms Counter
  wfE1RcvMfmAlms Counter
  wfE1MfsErrs Counter
  wfE1SyncLoss Counter
  wfE1RcvSig1s Counter
  wfE1RcvUnfrm1s Counter
  wfE1LineType INTEGER
  wfE1CRC4Errors Counter

Defined Values

wfE1Table 1.3.6.1.4.1.18.3.4.11
E1 line record
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WfE1Entry

wfE1Entry 1.3.6.1.4.1.18.3.4.11.1
An entry in the E1 table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  WfE1Entry  

wfE1Delete 1.3.6.1.4.1.18.3.4.11.1.1
create/delete parameter, dflt = created
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER created(1), deleted(2)  

wfE1Disable 1.3.6.1.4.1.18.3.4.11.1.2
enable/disable parameter, dflt = enabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfE1State 1.3.6.1.4.1.18.3.4.11.1.3
line driver state variable, Not Present, Init, Up
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), init(3), notpresent(4)  

wfE1Slot 1.3.6.1.4.1.18.3.4.11.1.4
instance ID Slot, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..14  

wfE1Connector 1.3.6.1.4.1.18.3.4.11.1.5
instance ID Connector, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER one(1), two(2)  

wfE1Madr 1.3.6.1.4.1.18.3.4.11.1.6
Line mac address, filled in by driver
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

wfE1HDB3Support 1.3.6.1.4.1.18.3.4.11.1.7
HDB3 Support - Enables or disables high density bipolar coding
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wfE1ClockMode 1.3.6.1.4.1.18.3.4.11.1.8
Clock Mode - Specifies the source of the E1 transmit clock
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), slave(2), manual(4)  

wfE1MiniDacs 1.3.6.1.4.1.18.3.4.11.1.9
MiniDacs Configuration - assigns each E1 channel to a specific function
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

wfE1BipolarVios 1.3.6.1.4.1.18.3.4.11.1.10
Number of Bipolar Violations
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1FrameErrs 1.3.6.1.4.1.18.3.4.11.1.11
Number of Frame errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1RcvRemAlms 1.3.6.1.4.1.18.3.4.11.1.12
Number of remote alarms received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1RcvMfmAlms 1.3.6.1.4.1.18.3.4.11.1.13
Number of Multiframe Alarms Received
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1MfsErrs 1.3.6.1.4.1.18.3.4.11.1.14
Number of instances of CAS Multiframe resync criteria met
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1SyncLoss 1.3.6.1.4.1.18.3.4.11.1.15
Number of instances of sync loss
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1RcvSig1s 1.3.6.1.4.1.18.3.4.11.1.16
Number of instances of receive signalling all 1's
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1RcvUnfrm1s 1.3.6.1.4.1.18.3.4.11.1.17
Number of instances of Receive unframed all 1's
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

wfE1LineType 1.3.6.1.4.1.18.3.4.11.1.18
Enable/Disable CRC-4
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER e1(1), e1crc4(2)  

wfE1CRC4Errors 1.3.6.1.4.1.18.3.4.11.1.19
Count of CRC-4 Errors
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter