WS-SW-MSTP-MIB

File: WS-SW-MSTP-MIB.mib (30765 bytes)

Imported modules

BRIDGE-MIB Q-BRIDGE-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC WS-SMI
WS-TYPE-MIB

Imported symbols

dot1dBridge BridgeId VlanId
OBJECT-GROUP MODULE-COMPLIANCE Integer32
OBJECT-TYPE MODULE-IDENTITY Counter32
DisplayString wsSw AbbrevRowStatus

Defined Types

TruthValue  
INTEGER true(1), false(2)    

MstiOrCistInstanceIndex  
INTEGER 0..16    

PortIndex  
INTEGER 1..4094    

PortIndexOrZero  
INTEGER 0..2147483647    

PortId  
OCTET STRING Size(2)    

BpduCounter  
Counter32    

MstiInstanceIndex  
INTEGER 1..64    

WsSwMstMapEntry  
SEQUENCE    
  wsSwMstMapIndex MstiOrCistInstanceIndex
  wsSwMstMapVlans1k OCTET STRING
  wsSwMstMapVlans2k OCTET STRING
  wsSwMstMapVlans3k OCTET STRING
  wsSwMstMapVlans4k OCTET STRING

WsSwMstVlanEntry  
SEQUENCE    
  wsSwMstVlanIndex VlanId
  wsSwMstVlanMstIndex MstiOrCistInstanceIndex

WsSwMstpPortEntry  
SEQUENCE    
  wsSwMstpPortIndex PortIndex
  wsSwMstpPortAdminMACEnable TruthValue
  wsSwMstpPortOperMACEnable TruthValue
  wsSwMstpPortAutoEdge TruthValue
  wsSwMstpPortDesignatedBridge BridgeId
  wsSwMstpPortGuardRoot TruthValue
  wsSwMstpAdminPortPortfastBpduFilter INTEGER
  wsSwMstpOperPortPortfastBpduFilter TruthValue
  wsSwMstpAdminPortPortfastBpduGuard INTEGER
  wsSwMstpOperPortPortfastBpduGuard TruthValue
  wsSwMstpPortVersion INTEGER

WsSwMstpXstEntry  
SEQUENCE    
  wsSwMstpXstId MstiOrCistInstanceIndex
  wsSwMstpXstBridgePriority INTEGER
  wsSwMstpXstBridgeId BridgeId
  wsSwMstpXstDesignatedRoot BridgeId
  wsSwMstpXstInternalRootCost Integer32
  wsSwMstpXstRootPort PortIndexOrZero
  wsSwMstpXstMasterPort PortIndexOrZero
  wsSwMstpXstRowStatus AbbrevRowStatus

WsSwMstpXstPortEntry  
SEQUENCE    
  wsSwMstpXstPortXstId MstiOrCistInstanceIndex
  wsSwMstpXstPortIndex PortIndex
  wsSwMstpXstPortState INTEGER
  wsSwMstpXstPortRole INTEGER
  wsSwMstpXstPortInternalRootCost Integer32
  wsSwMstpXstPortDesignatedBridge BridgeId
  wsSwMstpXstPortDesignatedPort PortId
  wsSwMstpXstPortPriority INTEGER
  wsSwMstpXstPortAdminInternalPathCost INTEGER
  wsSwMstpXstPortOperInternalPathCost Integer32

Defined Values

wsSwMstp 1.3.6.1.4.1.388.14.2.14
Symbol MIB for MSTP
MODULE-IDENTITY    

wsSwMstpGen 1.3.6.1.4.1.388.14.2.14.10
OBJECT IDENTIFIER    

wsSwMstpGenMaxHops 1.3.6.1.4.1.388.14.2.14.10.14
Specifies the maximum allowed hops for a BPDU in an MST region. This parameter is used by all the instances of the MST.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 7..127  

wsSwMstpVersionsSupported 1.3.6.1.4.1.388.14.2.14.10.19
An indication of wheter the Bridge supports Spanning Tree Protocol. The bit nonStp(0) indicates, the Bridge doesn't support any Spanning Tree Protocol. The bit 'dot1d1998(1)' indicates the Spanning Tree Protocol specified in EEE 802.1D-1998, 'dot1w(2)' indicates the Rapid Spanning Tree Protocol specified in IEEE Std 802.1w, 'dot1d2004' indicates IEEE Std 802.1D-2004 and 'dot1s(4) means MSTP IEEE Std 802.1s. When the bridge supprts a non-listed version, the bit unknown(15) should be set.
Status: current Access: read-only
OBJECT-TYPE    
  BITS nonStp(0), dot1d1998(1), dot1w(2), dot1d2004(3), dot1s(4), dot1q(5), reserved6(6), reserved7(7), reserved8(8), reserved9(9), reserved10(10), reserved11(11), reserved12(12), reserved13(13), reserved14(14), unknown(15)  

wsSwMstpGenProtocolVersion 1.3.6.1.4.1.388.14.2.14.10.20
This object is relevant if the Bridges that can supply a number of versions of STP. For GET operation this object reflects the mode in which the Bridge works currently. If the Bridge works currently in the version, not listed here, the value unknown(4) must be returned. For SET operation the value unknown(15) must be rejected. Another value may be rejected too if the Bridge does not support correspond mode (see wsSwMstpVersionsSupported). The value forceNonStp(0) indicates, the Spanning Tree Protocol is disabled on the Bridge (or the Spanning Tree Protocol Emulation operates). Other possible values are described in IEEE Std 802.1s clause 12.8.1.3.e)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forceNonStp(0), forceLegacyDot1d(1), forceDot1w(2), autoDot1s(3), unknown(15)  

wsSwMstpGenCfgIdFmtSel 1.3.6.1.4.1.388.14.2.14.10.30
Configuration Identificator Format Selector.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpGenCfgIdName 1.3.6.1.4.1.388.14.2.14.10.31
The configuration name that identifies the MST region and is used as one of the inputs in the computation of the MST Configuration Identifier.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(32)  

wsSwMstpGenCfgIdRevLevel 1.3.6.1.4.1.388.14.2.14.10.32
This object identifies the MST revision that identifies the MST region and is used as one of the inputs in the computation of the MST configuration Identifier.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..255  

wsSwMstpGenCfgIdDigest 1.3.6.1.4.1.388.14.2.14.10.33
The computed Configuration Digest.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

wsSwMstpGenRegionalRoot 1.3.6.1.4.1.388.14.2.14.10.36
Regional root of the CIST.
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

wsSwMstpGenExternalRootCost 1.3.6.1.4.1.388.14.2.14.10.37
External root cost of CIST.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpErrdisableTimeout 1.3.6.1.4.1.388.14.2.14.10.50
The BPDU guard feature shuts down the port on receiving a BPDU on a BPDU-guard enabled port. This object associates a timer with the feature such that the port gets enabled back without manual intervention after a set interval. This interval can be configured by the user using object wsSwMstpErrdisableTimeoutInterval
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpErrdisableTimeoutInterval 1.3.6.1.4.1.388.14.2.14.10.51
Specifies the time interval in seconds after which a port for which wsSwMstpErrdisableTimeout is true, is brought back up.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..10000000  

wsSwMstpPortfastBpduFilter 1.3.6.1.4.1.388.14.2.14.10.52
Enabling the BPDU Filter feature ensures that PortFastenabled ports (edge ports for which dot1dStpPortOperEdgePort is true) do not transmit or receive any BPDUs
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpPortFastBpduGuard 1.3.6.1.4.1.388.14.2.14.10.53
When the BPDU Guard feature is set for a bridge, all portfast-enabled ports (edge ports for which dot1dStpPortOperEdgePort is true) of the bridge that have bpdu-guard set to default shut down the port on receiving a BPDU. In this case, the BPDU is not processed.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpAdminCiscoInteroperability 1.3.6.1.4.1.388.14.2.14.10.54
Enabled interoperability with Cisco's version of MSTP
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpOperCiscoInteroperability 1.3.6.1.4.1.388.14.2.14.10.55
The operational value of the Cisco interoperability parameter. True if Cisco interoperability is administratively enabled and a Cisco BPDU is detected.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpGlobalState 1.3.6.1.4.1.388.14.2.14.10.56
The global state of MSTP in the switch. The possible states are enabled, disabled and disabledWithBridgeForward
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

wsSwMstMapTable 1.3.6.1.4.1.388.14.2.14.11
This table contains one entry for each instance of MSTP.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsSwMstMapEntry

wsSwMstMapEntry 1.3.6.1.4.1.388.14.2.14.11.1
A conceptual row containing the status of the MSTP instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  WsSwMstMapEntry  

wsSwMstMapIndex 1.3.6.1.4.1.388.14.2.14.11.1.1
Uniquely identifies an instance. The entry of this table with index 0 presents always, represents CIST. However, a SET operation at the CIST index returns an error.
Status: current Access: read-only
OBJECT-TYPE    
  MstiOrCistInstanceIndex  

wsSwMstMapVlans1k 1.3.6.1.4.1.388.14.2.14.11.1.6
A string of octets containing one bit per VLAN. The first octet corresponds to VLANs with VlanIndex values 1 through 8; the second octet to VLANs 9 through 16 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

wsSwMstMapVlans2k 1.3.6.1.4.1.388.14.2.14.11.1.7
A string of octets containing one bit per VLAN for VLANS with VlanIndex values 1024 through 2047. The first octet corresponds to VLANs with VlanIndex values 1024 through 1031; the second octet to VLANs 1032 through 1039 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

wsSwMstMapVlans3k 1.3.6.1.4.1.388.14.2.14.11.1.8
A string of octets containing one bit per VLAN for VLANS with VlanIndex values 2048 through 3071. The first octet corresponds to VLANs with VlanIndex values of 2048 through 2055; the second octet to VLANs 2056 through 2063 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

wsSwMstMapVlans4k 1.3.6.1.4.1.388.14.2.14.11.1.9
A string of octets containing one bit per VLAN for VLANS with VlanIndex values 3072 through 4095. The first octet corresponds to VLANs with VlanIndex values 3072 through 3079; the second octet to VLANs 3080 through 3087 etc. The most significant bit of each octet corresponds to the lowest VlanIndex value in that octet. For each VLAN that is mapped to this MSTP instance, the bit corresponding to that VLAN is set to '1'. Empty (zero) most significant octes are not mandatory.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

wsSwMstVlanTable 1.3.6.1.4.1.388.14.2.14.12
This table contains one entry for each VlanId.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsSwMstVlanEntry

wsSwMstVlanEntry 1.3.6.1.4.1.388.14.2.14.12.1
Information regarding the instance to which each Vlan is mapped.
Status: current Access: not-accessible
OBJECT-TYPE    
  WsSwMstVlanEntry  

wsSwMstVlanIndex 1.3.6.1.4.1.388.14.2.14.12.1.1
The VlanId for which this entry contains the instance mapped.
Status: current Access: read-only
OBJECT-TYPE    
  VlanId  

wsSwMstVlanMstIndex 1.3.6.1.4.1.388.14.2.14.12.1.2
An integer with values ranging from 0 to 16 that identify the CIST/MSTI instance to which this VLAN is mapped
Status: current Access: read-only
OBJECT-TYPE    
  MstiOrCistInstanceIndex  

wsSwMstpPortTable 1.3.6.1.4.1.388.14.2.14.13
A table that contains generic information about every port that is associated with this bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsSwMstpPortEntry

wsSwMstpPortEntry 1.3.6.1.4.1.388.14.2.14.13.1
A list of information for each port of the bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  WsSwMstpPortEntry  

wsSwMstpPortIndex 1.3.6.1.4.1.388.14.2.14.13.1.1
A unique value, greater than zero, for each Port. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
Status: current Access: read-only
OBJECT-TYPE    
  PortIndex  

wsSwMstpPortAdminMACEnable 1.3.6.1.4.1.388.14.2.14.13.1.2
The value of the MAC Enabled parameter (6.4.2 of IEEE Std 802.1D, 1998 Edition). May be present if the implementation supports the MAC Enabled parameter.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpPortOperMACEnable 1.3.6.1.4.1.388.14.2.14.13.1.3
The operational value of the MAC Enabled parameter (6.4.2 of IEEE Std 802.1D, 1998 Edition). May be present if the implementation supports the MAC Enabled parameter.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wsSwMstpPortAutoEdge 1.3.6.1.4.1.388.14.2.14.13.1.9
Optional and provided only by MSTP Bridges that support the automatic identification of edge ports.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpPortDesignatedBridge 1.3.6.1.4.1.388.14.2.14.13.1.14
The designated bridge for this port
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

wsSwMstpPortGuardRoot 1.3.6.1.4.1.388.14.2.14.13.1.50
If set to true, makes sure that the port on which it is enabled is a designated port. If the Root Guard enabled port receives a superior BPDU, it goes to a discarding state.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

wsSwMstpAdminPortPortfastBpduFilter 1.3.6.1.4.1.388.14.2.14.13.1.51
Enabling the Port BPDU Filter feature ensures that PortFastenabled ports (edge ports for which dot1dStpPortOperEdgePort is true) do not transmit or receive any BPDUs. When set to enabled or disabled, this configuration takes precedence over wsSwMstpPortfastBpduFilter. However, when setto default, the bridge level BPDU-filter configuration takes effect for the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1), default(2)  

wsSwMstpOperPortPortfastBpduFilter 1.3.6.1.4.1.388.14.2.14.13.1.52
The operational value for Portfast BPDU Filter for this port
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wsSwMstpAdminPortPortfastBpduGuard 1.3.6.1.4.1.388.14.2.14.13.1.53
When the BPDU Guard feature is set for a bridge, all portfast-enabled ports (edge ports for which dot1dStpPortOperEdgePort is true) of the bridge that have bpdu-guard set to default shut down the port on receiving a BPDU. In this case, the BPDU is not processed. When set to enabled or disabled, this configuration takes precedence over wsSwMstpPortfastBpduGuard. However, when setto default, the bridge level BPDU-guard configuration takes effect for the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1), default(2)  

wsSwMstpOperPortPortfastBpduGuard 1.3.6.1.4.1.388.14.2.14.13.1.54
The operational value for Portfast BPDU guard for this port
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wsSwMstpPortVersion 1.3.6.1.4.1.388.14.2.14.13.1.55
The spanning tree version used by BPDU's sent and received on this port
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER stp(0), reserved(1), rstp(2), mstp(3)  

wsSwMstpXstTable 1.3.6.1.4.1.388.14.2.14.14
A table that contains information about every MST instance on this bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsSwMstpXstEntry

wsSwMstpXstEntry 1.3.6.1.4.1.388.14.2.14.14.1
A list of information for each instance on this bridge
Status: current Access: not-accessible
OBJECT-TYPE    
  WsSwMstpXstEntry  

wsSwMstpXstId 1.3.6.1.4.1.388.14.2.14.14.1.1
The instance id.
Status: current Access: read-only
OBJECT-TYPE    
  MstiOrCistInstanceIndex  

wsSwMstpXstBridgePriority 1.3.6.1.4.1.388.14.2.14.14.1.2
Bridge priority, in steps of 4096.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..61440  

wsSwMstpXstBridgeId 1.3.6.1.4.1.388.14.2.14.14.1.3
The bridge ID for this instance
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

wsSwMstpXstDesignatedRoot 1.3.6.1.4.1.388.14.2.14.14.1.4
The designated root for this instance
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

wsSwMstpXstInternalRootCost 1.3.6.1.4.1.388.14.2.14.14.1.6
The internal root cost for this instance
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpXstRootPort 1.3.6.1.4.1.388.14.2.14.14.1.7
The root port for this instance, if on this bridge.
Status: current Access: read-only
OBJECT-TYPE    
  PortIndexOrZero  

wsSwMstpXstMasterPort 1.3.6.1.4.1.388.14.2.14.14.1.8
The master port for this instance, if on this bridge. Non zero value may not be in CIST.
Status: current Access: read-only
OBJECT-TYPE    
  PortIndexOrZero  

wsSwMstpXstRowStatus 1.3.6.1.4.1.388.14.2.14.14.1.9
row status: only createAndGo, destroy, active are supported.
Status: current Access: read-create
OBJECT-TYPE    
  AbbrevRowStatus  

wsSwMstpXstPortTable 1.3.6.1.4.1.388.14.2.14.15
A table to manage ports inside instances - both CIST and MSTIs. It contains objects, describing ports and is common for these both types of instances.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WsSwMstpXstPortEntry

wsSwMstpXstPortEntry 1.3.6.1.4.1.388.14.2.14.15.1
A list of information for each port in each instance for this bridge.
Status: current Access: not-accessible
OBJECT-TYPE    
  WsSwMstpXstPortEntry  

wsSwMstpXstPortXstId 1.3.6.1.4.1.388.14.2.14.15.1.1
The instance id. 0 means CIST.
Status: current Access: read-only
OBJECT-TYPE    
  MstiOrCistInstanceIndex  

wsSwMstpXstPortIndex 1.3.6.1.4.1.388.14.2.14.15.1.2
The value of wsSwMstpPortIndex of the Port in wsSwMstpPortTable.
Status: current Access: read-only
OBJECT-TYPE    
  PortIndex  

wsSwMstpXstPortState 1.3.6.1.4.1.388.14.2.14.15.1.3
The state the port is in.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), discarding(1), learning(2), forwarding(3), unknown(4)  

wsSwMstpXstPortRole 1.3.6.1.4.1.388.14.2.14.15.1.4
The role of this port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), alternate(2), backup(3), root(4), designated(5), master(6), nonStp(7), unknown(8)  

wsSwMstpXstPortInternalRootCost 1.3.6.1.4.1.388.14.2.14.15.1.9
The internal root path cost for this port in this instance
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpXstPortDesignatedBridge 1.3.6.1.4.1.388.14.2.14.15.1.10
The designated bridge ID for this port in this instance
Status: current Access: read-only
OBJECT-TYPE    
  BridgeId  

wsSwMstpXstPortDesignatedPort 1.3.6.1.4.1.388.14.2.14.15.1.14
The designated port id
Status: current Access: read-only
OBJECT-TYPE    
  PortId  

wsSwMstpXstPortPriority 1.3.6.1.4.1.388.14.2.14.15.1.15
Port priority, in steps of 16.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..255  

wsSwMstpXstPortAdminInternalPathCost 1.3.6.1.4.1.388.14.2.14.15.1.16
The value of the internal path cost. The value 0 means, that the cost will be selected automatically.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..200000000  

wsSwMstpXstPortOperInternalPathCost 1.3.6.1.4.1.388.14.2.14.15.1.17
The operational value of the internal path cost
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

wsSwMstpOptionSupport 1.3.6.1.4.1.388.14.2.14.16
OBJECT IDENTIFIER    

wsSwMstpOptionPortAdminMACEnable 1.3.6.1.4.1.388.14.2.14.16.1
If this is true, swWsMstpPortAdminMACEnable can be set
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wsSwMstpOptionPortAutoEdge 1.3.6.1.4.1.388.14.2.14.16.2
If this is true wsSwMstpPortAutoEdge can be set
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

wsSwMstpConformance 1.3.6.1.4.1.388.14.2.14.100
OBJECT IDENTIFIER    

wsSwMstpGroups 1.3.6.1.4.1.388.14.2.14.100.1
OBJECT IDENTIFIER    

currentObjectGroup 1.3.6.1.4.1.388.14.2.14.100.1.1
OBJECT-GROUP for WS-SW-MSTP-MIB
Status: current Access: read-only
OBJECT-GROUP    

wsSwMstpCompliances 1.3.6.1.4.1.388.14.2.14.100.2
OBJECT IDENTIFIER    

basicCompliance 1.3.6.1.4.1.388.14.2.14.100.2.1
MODULE-COMPLIANCE for WS-SW-MSTP-MIB
Status: current Access: read-only
MODULE-COMPLIANCE