VOICE-OPT-MIB

File: VOICE-OPT-MIB.mib (128864 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

Counter Gauge enterprises
OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

PhysicalPortNumber  
INTEGER 1..54    

Cdx6500PPCTVoicePortEntry  
SEQUENCE    
  cdx6500VoiceCfgPortNumber INTEGER
  cdx6500VoiceCfgPortType INTEGER
  cdx6500VoiceCfgInterfaceType INTEGER
  cdx6500VoiceCfgSignalingType INTEGER
  cdx6500VoiceCfgELeadFilter INTEGER
  cdx6500VoiceCfgHybridFXS INTEGER
  cdx6500VoiceCfgHybridEAndM2 INTEGER
  cdx6500VoiceCfgSignalingMode INTEGER
  cdx6500VoiceCfgSignalingControl INTEGER
  cdx6500VoiceCfgNoOfDigitsToCollect INTEGER
  cdx6500VoiceCfgNoOfRings INTEGER
  cdx6500VoiceCfgPCMMode INTEGER
  cdx6500VoiceCfgCompressionRate INTEGER
  cdx6500VoiceCfgDSIControl INTEGER
  cdx6500VoiceCfgSmoothingDelay INTEGER
  cdx6500VoiceCfgEchoControl INTEGER
  cdx6500VoiceCfgEchoReturnLoss INTEGER
  cdx6500VoiceCfgTxInputSignalLevel DisplayString
  cdx6500VoiceCfgRxOutputSignalLevel DisplayString
  cdx6500VoiceCfgFaxSupport INTEGER
  cdx6500VoiceCfgFaxRates INTEGER
  cdx6500VoiceCfgVoiceBandDetection INTEGER
  cdx6500VoiceCfgAutoCallMnemonic DisplayString
  cdx6500VoiceCfgCallControl INTEGER
  cdx6500VoiceCfgAutoCallTimeout INTEGER
  cdx6500VoiceCfgCallRetries INTEGER
  cdx6500VoiceCfgGroupSubaddress INTEGER
  cdx6500VoiceCfgBilling INTEGER
  cdx6500VoiceCfgRxSignalingStateChangeFilter INTEGER
  cdx6500VoiceCfgT1E1RxIdleOnhookState DisplayString
  cdx6500VoiceCfgT1E1TxIdleOnhookState DisplayString
  cdx6500VoiceCfgT1E1RxActiveOffhookState DisplayString
  cdx6500VoiceCfgT1E1TxActiveOffhookState DisplayString
  cdx6500VoiceCfgT1E1RingingState DisplayString
  cdx6500VoiceCfgT1E1NoRingingState DisplayString
  cdx6500VoiceCfgRxWinkStartTimer INTEGER
  cdx6500VoiceCfgRxMinimumReceiveWink INTEGER
  cdx6500VoiceCfgRxCalledEndGlareDetect INTEGER
  cdx6500VoiceCfgRxFirstDigitTimer INTEGER
  cdx6500VoiceCfgRxInterdigitTimer INTEGER
  cdx6500VoiceCfgTxWinkDelay INTEGER
  cdx6500VoiceCfgTxWinkWidth INTEGER
  cdx6500VoiceCfgTxDigitDelay INTEGER
  cdx6500VoiceCfgTxDigitOn INTEGER
  cdx6500VoiceCfgTxInterdigitTime INTEGER
  cdx6500VoiceCfgRxInterringWait INTEGER
  cdx6500VoiceCfgRxRingStateChangeFilter INTEGER
  cdx6500VoiceCfgTxRingerOffLong INTEGER
  cdx6500VoiceCfgTxRingerOffShort INTEGER
  cdx6500VoiceCfgTxRingerOn INTEGER
  cdx6500VoiceCfgRxDisconnectTimer INTEGER
  cdx6500VoiceCfgRxCalledEndDisconnectDelayTimer INTEGER
  cdx6500VoiceCfgLineErrorRecovery INTEGER
  cdx6500VoiceCfgSignalingSampleRate INTEGER
  cdx6500VoiceCfgWaitForParams INTEGER
  cdx6500VoiceCfgSpareTimer1 INTEGER
  cdx6500VoiceCfgSpareTimer2 INTEGER
  cdx6500VoiceCfgTxInterdigitPauseTime INTEGER
  cdx6500VoiceCfgRxMinimumFlashHookTime INTEGER
  cdx6500VoiceCfgRxMaximumFlashHookTime INTEGER
  cdx6500VoiceCfgTransparentSignalingIdleState DisplayString
  cdx6500VoiceCfgTransparentRxDisconnectFilter INTEGER
  cdx6500VoiceCfgTransparentSignalingBusyoutState DisplayString
  cdx6500VoiceCfgXlateSigInfo0000FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1000FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0100FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1100FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0010FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1010FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0110FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1110FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0001FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1001FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0101FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1101FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0011FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1011FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo0111FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgXlateSigInfo1111FromRemoteToLocalPort DisplayString
  cdx6500VoiceCfgDialToneLowerFrequency INTEGER
  cdx6500VoiceCfgDialToneLowerFrequencyAmplitude DisplayString
  cdx6500VoiceCfgDialToneUpperFrequency INTEGER
  cdx6500VoiceCfgDialToneUpperFrequencyAmplitude DisplayString
  cdx6500VoiceCfgRingBackToneLowerFrequency INTEGER
  cdx6500VoiceCfgRingBackToneLowerFrequencyAmplitude DisplayString
  cdx6500VoiceCfgRingBackToneUpperFrequency INTEGER
  cdx6500VoiceCfgRingBackToneUpperFrequencyAmplitude DisplayString
  cdx6500VoiceCfgBusyToneLowerFrequency INTEGER
  cdx6500VoiceCfgBusyToneLowerFrequencyAmplitude DisplayString
  cdx6500VoiceCfgBusyToneUpperFrequency INTEGER
  cdx6500VoiceCfgBusyToneUpperFrequencyAmplitude DisplayString
  cdx6500VoiceCfgTxBusyToneOffTime INTEGER
  cdx6500VoiceCfgTxBusyToneOnTime INTEGER
  cdx6500VoiceCfgFastBusyToneLowerFrequency INTEGER
  cdx6500VoiceCfgFastBusyToneLowerFrequencyAmplitude DisplayString
  cdx6500VoiceCfgFastBusyToneUpperFrequency INTEGER
  cdx6500VoiceCfgFastBusyToneUpperFrequencyAmplitude DisplayString
  cdx6500VoiceCfgTxFastBusyToneOffTime INTEGER
  cdx6500VoiceCfgTxFastBusyToneOnTime INTEGER
  cdx6500VoiceCfgHybridFXO INTEGER
  cdx6500VoiceCfgTxPulse INTEGER
  cdx6500VoiceCfgRxMinPulse INTEGER
  cdx6500VoiceCfgRxMaxPulse INTEGER
  cdx6500VoiceCfgTxMasterClear INTEGER
  cdx6500VoiceCfgRxMinMasterClear INTEGER
  cdx6500VoiceCfgRxMaxMasterClear INTEGER
  cdx6500VoiceCfgTxSlaveClear INTEGER
  cdx6500VoiceCfgRxMinSlaveClear INTEGER
  cdx6500VoiceCfgRxMaxSlaveClear INTEGER
  cdx6500VoiceCfgTxSlaveRelease INTEGER
  cdx6500VoiceCfgRxMinSlaveRelease INTEGER
  cdx6500VoiceCfgRxMaxSlaveRelease INTEGER
  cdx6500VoiceCfgTxPTSTime INTEGER
  cdx6500VoiceCfgRxPTSTime INTEGER
  cdx6500VoiceCfgMasterGuard INTEGER
  cdx6500VoiceCfgSlaveGuard INTEGER
  cdx6500VoiceCfgTxFlashHookTime INTEGER
  cdx6500VoiceCfgDtmfAmplitude DisplayString
  cdx6500VoiceCfgFXSOffhookFilter INTEGER

Cdx6500VoiceSwitchEntry  
SEQUENCE    
  cdx6500VoiceSwitchRxDTMFDigitString DisplayString
  cdx6500VoiceSwitchNumRxDigitToReceive INTEGER
  cdx6500VoiceSwitchCallParam DisplayString
  cdx6500VoiceSwitchAlternateDestination INTEGER
  cdx6500VoiceSwitchCompressionOverrideRate INTEGER
  cdx6500VoiceSwitchNumLeadingDigitToStrip INTEGER
  cdx6500VoiceSwitchPreFixDigits DisplayString
  cdx6500VoiceSwitchPostFixDigits DisplayString
  cdx6500VoiceSwitchEntryNumber INTEGER

Cdx6500PPSTVoicePortEntry  
SEQUENCE    
  cdx6500VoiceStatsPortNumber INTEGER
  cdx6500VoiceStatsPortInterfaceType INTEGER
  cdx6500VoiceStatsHWRevAndPartNumber DisplayString
  cdx6500VoiceStatsFortyEightVolts INTEGER
  cdx6500VoiceStatsPortState INTEGER
  cdx6500VoiceStatsCircuitState INTEGER
  cdx6500VoiceStatsCurrentMode INTEGER
  cdx6500VoiceStatsTimeOfLastStatReset DisplayString
  cdx6500VoiceStatsCallDuration DisplayString
  cdx6500VoiceStatsTotalCallDuration DisplayString
  cdx6500VoiceStatsPortUtilization INTEGER
  cdx6500VoiceStatsNumberOfCalls Counter
  cdx6500VoiceStatsLastDigitsTransmitted DisplayString
  cdx6500VoiceStatsLastDigitsReceived DisplayString
  cdx6500VoiceStatsTxPacketDropped Counter
  cdx6500VoiceStatsRxPacketDropped Counter
  cdx6500VoiceStatsDroppedPackets Counter
  cdx6500VoiceStatsDSPInternalFaults Counter
  cdx6500VoiceStatsTxPackets Counter
  cdx6500VoiceStatsRxPackets Counter
  cdx6500VoiceStatsTxPacketsPerSecond Counter
  cdx6500VoiceStatsRxPacketsPerSecond Counter
  cdx6500VoiceStatsDSIEfficiency INTEGER
  cdx6500VoiceStatsCurrentRate INTEGER
  cdx6500VoiceStatsInputPower DisplayString
  cdx6500VoiceStatsOutputPower DisplayString
  cdx6500VoiceStatsFAXTransmissions INTEGER
  cdx6500VoiceStatsUnsupportedFmtsFAXXmissions INTEGER
  cdx6500PPSTSignalingSequenceTrapTxState DisplayString
  cdx6500PPSTSignalingSequenceTrapRxState DisplayString
  cdx6500PPSTSignalingSequenceTrapMachineState DisplayString
  cdx6500PPSTSignalingSequenceTrapTimeSinceLastChange INTEGER
  cdx6500PPSTSignalingSequenceTrapComment DisplayString
  cdx6500VoiceStatsCurrentStatus INTEGER
  cdx6500VoiceStatsLastClearCauseCode DisplayString
  cdx6500VoiceStatsLastClearDiagnosticCode DisplayString
  cdx6500VoiceStatsLastInboundCallPacketCalledAddress DisplayString
  cdx6500VoiceStatsLastInboundCallPacketCallingAddress DisplayString
  cdx6500VoiceStatsLastInboundCallPacketFacilities DisplayString
  cdx6500VoiceStatsLastInboundCallPacketCUD DisplayString
  cdx6500VoiceStatsLastOutboundCallPacketCalledAddress DisplayString
  cdx6500VoiceStatsLastOutboundCallPacketCallingAddress DisplayString
  cdx6500VoiceStatsLastOutboundCallPacketFacilities DisplayString
  cdx6500VoiceStatsLastOutboundCallPacketCUD DisplayString
  cdx6500VoiceStatsRingerStatus INTEGER
  cdx6500VoiceStatsDSPMSMSlotNumber INTEGER
  cdx6500VoiceStatsDSPMNumber INTEGER
  cdx6500VoiceStatsT1E1PortNumber INTEGER
  cdx6500VoiceStatsTimeSlotNumber DisplayString
  cdx6500VoiceStatsDaughterCardRevAndPartNumber DisplayString
  cdx6500VoiceStatsVADEfficiency INTEGER
  cdx6500VoiceStatsMeanDelayDeviation INTEGER
  cdx6500VoiceStatsMaxDelayDeviation DisplayString
  cdx6500VoiceStatsPktRecResync INTEGER
  cdx6500VoiceCallStatsNoPacketDropped DisplayString
  cdx6500VoiceCallStatsNoCallsDropped DisplayString
  cdx6500VoiceCallStatsDroppedReason0 DisplayString
  cdx6500VoiceCallStatsDroppedReason1 DisplayString
  cdx6500VoiceCallStatsDroppedReason3 DisplayString
  cdx6500VoiceCallStatsDroppedReason5 DisplayString
  cdx6500VoiceCallStatsDroppedReason9 DisplayString
  cdx6500VoiceCallStatsDroppedReason11 DisplayString
  cdx6500VoiceCallStatsDroppedReason13 DisplayString
  cdx6500VoiceCallStatsDroppedReason17 DisplayString
  cdx6500VoiceCallStatsDroppedReason19 DisplayString
  cdx6500VoiceCallStatsDroppedReason21 DisplayString
  cdx6500VoiceCallStatsDroppedReason33 DisplayString
  cdx6500VoiceCallStatsDroppedReason-Rest DisplayString

Cdx6500PPSTSignalingSequenceTrapEntry  
SEQUENCE    
  cdx6500SignalingSequenceTrapPortNumber INTEGER
  cdx6500SignalingSequenceTrapEventNumber INTEGER
  cdx6500SignalingSequenceTrapTxState DisplayString
  cdx6500SignalingSequenceTrapRxState DisplayString
  cdx6500SignalingSequenceTrapMachineState DisplayString
  cdx6500SignalingSequenceTrapTimeSinceLastChange INTEGER
  cdx6500SignalingSequenceTrapComment DisplayString

Cdx6500StatVCSEntry  
SEQUENCE    
  cdx6500StatVCSIndex INTEGER
  cdx6500StatVCSTime DisplayString
  cdx6500StatVCSNoPacketDropped INTEGER
  cdx6500StatVCSNoCallsDropped INTEGER
  cdx6500StatVCSDroppedReasons DisplayString
  cdx6500StatVCSNoCallsProcessed INTEGER
  cdx6500StatVCSPercentPeakAvgCurOfCPULoad DisplayString
  cdx6500StatVCSPercentPeakAvgCurOfDataBuf DisplayString
  cdx6500StatVCSPercentPeakAvgCurOfIORBBuf DisplayString

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500CfgGeneralGroup 1.3.6.1.4.1.449.2.1.2.2
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500StatNetworkSvcsGroup 1.3.6.1.4.1.449.2.1.3.4
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PCTVoicePortTable 1.3.6.1.4.1.449.2.1.2.1.1.25
OBJECT IDENTIFIER    

cdx6500PSTVoicePortTable 1.3.6.1.4.1.449.2.1.3.1.1.26
OBJECT IDENTIFIER    

cdx6500GCTVoiceSwitchTable 1.3.6.1.4.1.449.2.1.2.2.21
OBJECT IDENTIFIER    

cdx6500PPCTVoicePortTable 1.3.6.1.4.1.449.2.1.2.1.1.25.1
This table contains the port configuration parameters to configure the DSPM/E&M, DSPM/FXS, DSPM/HC, and DSPM/SM.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPCTVoicePortEntry

cdx6500PPCTVoicePortEntry 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1
A Voice Port Configuration Table Entry. Each entry contains the configuration parameters for a single Voice Port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPCTVoicePortEntry  

cdx6500VoiceCfgPortNumber 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.1
Port number of the Voice port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500VoiceCfgPortType 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.2
This parameter represents the port type of the port. voice :This is a voice port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER voice(43)  

cdx6500VoiceCfgInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.3
Select one of the following physical interfaces being used for this port. The entry must match the hardware. eAndM2 :2 wire E&M (Ear and Mouth) Interface. eAndM4 :4 wire E&M (Ear and Mouth) Interface. fxo :FXO (Foreign Exchange Office ) Interface. fxs :FXS (Foreign Exchange Station) Interface. nc :Skipped during configuration. eAndM2 is only displayed for port numbers 1..54.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eAndM2(1), eAndM4(2), fxo(3), fxs(4), nc(100)  

cdx6500VoiceCfgSignalingType 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.4
Select the E&M signalling type. i : EandMTypeI. ii : EandMTypeII. v : EandMTypeV. iii : EandMTypeIII. nc : Skipped during configuration. This parameter is displayed for DSPM/E&M and skipped for FXS, FXO, and all virtual port types.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER i(1), ii(2), v(3), iii(4), nc(100)  

cdx6500VoiceCfgELeadFilter 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.5
Selection for E lead filter enable or disable option. disabled : Disables E-lead filter. enabled : Enables E-lead filter. nc : Skipped during configuration. This parameter is displayed for DSPM/E&M and skipped for FXS, FXO, and all virtual port types.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500VoiceCfgHybridFXS 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.6
Hybrid balance filters and termination type based on country. sixHundred : 600 ohm interface for USA, Japan and Ireland. canada : 600 ohms with 2.16 uF germany : 220 ohms in series with (820 ohms in parallel with 115nF). uk : 300 ohms in series with (1K ohms in parallel with 220nF). belgium : 150 ohms in series with (830 ohms in parallel with 72nF). france : 215 ohms in series with (1K ohms in parallel with 137nF). nc : Skipped during configuration. This parameter is displayed for DSPM/FXS and skipped for DSPM/E&M, DSPM/HC(FXO) and all virtual port types.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sixHundred(1), canada(2), germany(3), uk(5), belgium(8), france(9), nc(100)  

cdx6500VoiceCfgHybridEAndM2 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.7
Hybrid balance filters and termination type based on country. (Only for E&M-2wire interfaces.) sixHundred : 600 ohm interface for USA, Japan and Ireland. germany : 220 ohms in series with (820 ohms in parallel with 115nF). uk : 370 ohms in series with (620 ohms in parallel with 310nF). nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sixHundred(1), germany(3), uk(10), nc(100)  

cdx6500VoiceCfgSignalingMode 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.8
Select the voice signalling mode. normal : Allows signalling to pass end to end and signalling will be used to control circuit state and packet flow. none : A permanent voice path is established and packet flow is always enabled, but no signalling will be passed through. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), none(2), nc(100)  

cdx6500VoiceCfgSignalingControl 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.9
Select signaling control transmission mode in E&M interface type. immediate : Digits are transmitted immediately. wink : Digits are transmitted after the WINK pulse. transparent : The voice signalling states are transmitted end to end without interpreting the signalling state. delay : Digits are transmitted after the end of the Delay Dial signal. masterColisee : 65xx is simulating Colisee master mode. slaveColisee : 65xx is simulating Colisee slave mode. seizureAcknowledge : Transmit Seizure acknowledge immediately after receiving a Seizure signal from the PBX. nc : Skipped during configuration. The parameter will be skipped for FXO & FXS type interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER immediate(1), wink(2), transparent(3), delay(4), masterColisee(5), slaveColisee(6), seizureAcknowledge(7), nc(100)  

cdx6500VoiceCfgNoOfDigitsToCollect 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.10
Select number of digits to collect before making a call. The parameter will not be supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..11  

cdx6500VoiceCfgNoOfRings 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.11
Number of rings to be received before a call can be accepted. This parameter is displayed for FXO and skipped for E&M and FXS interface types. A value of 0 implies that this parameter was skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..9  

cdx6500VoiceCfgPCMMode 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.12
Select the PCM encoder/decoder mode. aLaw :PCM encoder/decoder mode = A Law. muLaw :PCM encoder/decoder mode = Mu Law. nc :Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER aLaw(1), muLaw(2), nc(100)  

cdx6500VoiceCfgCompressionRate 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.13
Select the voice compression rate to be used by the DSP. cD8K : 8k CVSELP c16k : 16k CVSELP cBD8K : Bundled 8k CVSELP cB16k : Bundled 16k CVSELP. cE8Kb : Enhanced Bundled 8k CVSELP cE16Kb : Enhanced Bundled 16k CVSELP nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cD8K(1), cD16K(2), cBD8K(3), cBD16K(4), cE8Kb(12), cE16Kb(13), nc(100)  

cdx6500VoiceCfgDSIControl 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.14
Select if the Digital Speech Interpolation (Silence Detector) will be used with this channel. enabled : DSI is activated. disabled : DSI is not used. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500VoiceCfgSmoothingDelay 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.15
Select maximum inter packet arrival jitter due to network in milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..150  

cdx6500VoiceCfgEchoControl 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.16
Select echo control. disabled : Echo pass through. enabled : This enables echo control logic. nc : Skipped during configuration. Echo not detected and not cancelled. This parameter will be skipped in normal mode and only displayed when DEBUG is turned on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500VoiceCfgEchoReturnLoss 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.17
Select echo return loss in dBm. minus3 : -3 dBm. minus6 : -6 dBm. minus9 : -9 dBm. minus12 : -12dBm. nc :Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER minus3(2), minus6(3), minus9(4), minus12(5), nc(100)  

cdx6500VoiceCfgTxInputSignalLevel 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.18
Enter the input signal level. To be specified in steps of 0.5 dBm FXO Interface Type : 600 Ohms +6.0 to -2.5dbm 600 Ohms Adaptive +6.0 to -2.5dbm FXS Interface Type : 600 Ohms +6.0 to -6.0dbm Canada +6.0 to -5.5dbm UK +4.5 to -7.5dbm Germany +4.0 to -8.0dbm France -2.0 to -9.0dbm Belgium +4.0 to -8.0dbm E&M Interface Type : 4-Wire/600 +7.0 to -16.0dbm 2-Wire/600 +7.0 to -16.0dbm 2-Wire/UK +5.0 to -16.0dbm 2-Wire/Germany +5.0 to -16.0dbm Virtual Ports(100 and above): +8.0 to -6.0dbm Entering a negative number for the 'Input Signal Level' will result in the DSPM card amplifying the signal by that many dB. Entering a positive number for the 'Input Signal Level' will result in the DSPM card attenuating the signal by that many dB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgRxOutputSignalLevel 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.19
Enter the output signal level. To be selected in steps of 0.5 dBm. FXO Interface Type : 600 Ohms +0.0 to -8.0dbm 600 Ohms Adaptive +0.0 to -8.0dbm FXS Interface Type : 600 Ohms +0.0 to -9.0dbm Canada +0.0 to -9.0dbm UK -1.5 to -9.0dbm Germany -2.0 to -9.0dbm France -1.5 to -9.0dbm Belgium -1.5 to -9.0dbm E&M Interface Type : 4-Wire/600 +7.0 to -16.0dbm 2-Wire/600 +3.0 to -16.0dbm 2-Wire/UK +1.0 to -16.0dbm 2-Wire/Germany +0.0 to -16.0dbm Virtual Ports(100 and above): +6.0 to -8.0dbm Entering a negative number for the 'Output Signal Level' will result in the DSPM card attenuating the signal by that many dB. Entering a positive number for the 'Output Signal Level' will result in the DSPM card amplifying the signal by that many dB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgFaxSupport 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.20
This parameter selects whether the FAX data is to be supported. disabled : FAX data will not be detected. enabled : Detects presence of FAX data. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500VoiceCfgFaxRates 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.21
Specify the speed to switch to, when FAX data is detected. This parameter is ignored if Fax support was disabled. fr9600 : FAX to be transmitted across the network at 9600 bits per second. fr4800 : FAX to be transmitted across the network at 4800 bits per second. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER fr9600(1), fr4800(2), nc(100)  

cdx6500VoiceCfgVoiceBandDetection 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.22
Modem data detection. yes : Detection of modem data enabled. no : Detection of modem data disabled. nc : Skipped during configuration. This parameter will be skipped in normal mode.Displayed only when DEBUG is turned on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2), nc(100)  

cdx6500VoiceCfgAutoCallMnemonic 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.23
This mnemonic name is used to originate the call. It consists of 0 - 8 alphanumeric characters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500VoiceCfgCallControl 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.24
Select calling method. offhook : Call only when Offhook.Disconnect on Onhook. auto : SVC does not depend on On/Offhook condition.It remains established permanently after the power-up. switched : Call only when interface goes offhook and disconnect call when interface goes onhook. Destination is determined by the DTMF digits received. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER offhook(1), auto(2), switched(3), nc(100)  

cdx6500VoiceCfgAutoCallTimeout 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.25
Time interval between two successive calls in case of failure of previous call.Used only in `Auto' call control mode.This parameter will be skipped if Call Control is Offhook and Switched.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..255  

cdx6500VoiceCfgCallRetries 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.26
Enter maximum number of call retries when previous call failed.Used only in Auto Call Control mode.'0' means try forever. This parameter will be skipped if Call Control is Offhook and Switched.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cdx6500VoiceCfgGroupSubaddress 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.27
Specifies a port subaddress that is shared by several Voice ports. Incoming calls with this subaddress are routed to one of several ports sharing this subaddress. Another name for the group of ports with the same Group Subaddress is Hunt Group.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

cdx6500VoiceCfgBilling 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.28
This controls whether billing (accounting) records will be created for calls on this port. enabled : Billing is enabled. disabled : Billing is disabled. nc : Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500VoiceCfgRxSignalingStateChangeFilter 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.29
The amount of time to declare a valid supervisory signaling state change. The granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000  

cdx6500VoiceCfgT1E1RxIdleOnhookState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.30
The signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care.The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgT1E1TxIdleOnhookState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.31
The signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgT1E1RxActiveOffhookState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.32
The signalling state that represents the active state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. ` x' means don't care. The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgT1E1TxActiveOffhookState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.33
The signalling state that represents the active state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgT1E1RingingState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.34
The signalling state that represents the ringing state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care. The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgT1E1NoRingingState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.35
The signalling state that represents the no ringing state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface. For T1 SF ports these bits represent ABAB signalling bits. `x' means don't care. The range is from 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgRxWinkStartTimer 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.36
This is the maximum time to wait for the beginning of the wink signal from the PBX before declaring a wink start malfunction. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgRxMinimumReceiveWink 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.37
The amount of time required to declare a valid wink. Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..2000  

cdx6500VoiceCfgRxCalledEndGlareDetect 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.38
The length of time when a wink pulse will be detected as a glare condition. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 50..10000  

cdx6500VoiceCfgRxFirstDigitTimer 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.39
The maximum time (in seconds) to wait for the first DTMF digit before declaring a `busyout' state. Granularity is 1 second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

cdx6500VoiceCfgRxInterdigitTimer 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.40
This is the maximum time (in seconds) to wait for a subsequent receive digit before declaring a misdial. Granularity is 1 second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

cdx6500VoiceCfgTxWinkDelay 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.41
The time delay from receiving a valid Offhook state to start transmitting a wink. Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..1000  

cdx6500VoiceCfgTxWinkWidth 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.42
The width of the transmitted wink pulse. Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 10..2000  

cdx6500VoiceCfgTxDigitDelay 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.43
The time delay before transmitting the first DTMF digit after a wink is received.Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..5000  

cdx6500VoiceCfgTxDigitOn 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.44
The time DTMF digits are transmitted. Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 60..1000  

cdx6500VoiceCfgTxInterdigitTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.45
The time between transmitting DTMF digits. Granularity is 10 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 60..1000  

cdx6500VoiceCfgRxInterringWait 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.46
This is the maximum time to wait for subsequent receive rings before declaring a call abandoned condition. Granularity is 1 second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..60  

cdx6500VoiceCfgRxRingStateChangeFilter 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.47
The amount of time to declare the change in the ring state. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgTxRingerOffLong 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.48
This timer is the long off period for ringer cadences that have a short and long off period.For the cases where the ring cadence defines one off period, the Tx Ringer Off Long must be equal to Tx Ringer Off Short. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgTxRingerOffShort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.49
This timer is the short off period for ringer cadences that have a short and long off period.For the cases where the ring cadence defines one off period, the Tx Ringer Off Long must be equal to Tx Ringer Off Short. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgTxRingerOn 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.50
The time of the ringer on pulse. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgRxDisconnectTimer 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.51
The amount of time required to receive idle signaling to disconnect a call. For an analog FXO port, RX idle signaling is the loss of loop current. For a FXS port, RX idle signaling is when the interface goes onhook. For an analog E&M port, RX idle signaling is when the 'M' lead goes idle. For digital interfaces, the RX idle state is defined by the 'T1/E1 Rx Idle (on-hook) State' parameter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..30000  

cdx6500VoiceCfgRxCalledEndDisconnectDelayTimer 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.52
The additional amount of time beyond the Rx Disconnect filter the calling end must be Onhook to disconnect a call. Granularity is 1 second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..20  

cdx6500VoiceCfgLineErrorRecovery 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.53
The length of time voice will be suppressed after LOS or OF condition clears.Granularity is 10 milliseconds. This parameter will be displayed for virtual ports only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1000  

cdx6500VoiceCfgSignalingSampleRate 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.54
The time between sampling received signalling states and line states.Granularity is 1 millisecond. This parameter will be displayed only when the DEBUG flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..20  

cdx6500VoiceCfgWaitForParams 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.55
The amount of time to wait for a message to set the parameters after receiving a disconnect message (messages occur in the form of an event) before busying out the port. Granularity is 1 second. This parameter will be displayed only when the DEBUG flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..10  

cdx6500VoiceCfgSpareTimer1 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.56
Spare timer number 1.Granularity is 1 millisecond.This parameter will be displayed only when the DEBUG flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10000  

cdx6500VoiceCfgSpareTimer2 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.57
Spare timer number 2.Granularity is 1 millisecond. This parameter will be displayed only when the DEBUG flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10000  

cdx6500VoiceCfgTxInterdigitPauseTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.58
The time between transmitting DTMF digits. Enter in steps of 10 msec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..10000  

cdx6500VoiceCfgRxMinimumFlashHookTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.59
The shortest length of time required to be onhook to be recognized as a flash-hook. This value must be less than Rx Maximum Flash-Hook Time for flash-hook to be recognized.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgRxMaximumFlashHookTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.60
The longest length of time to be onhook to be recognized as a flash-hook. This value must be less than Rx Disconnect Timer for flash-hook to be recognized. Note: the average of the minimum and maximum flash-hook values will be the pulse width for a transmitted flash-hook.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgTransparentSignalingIdleState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.61
The received signalling state that represents the idle state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface.`x' means don't care. For E&M analog ports, Onhook is assumed for the idle state. The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgTransparentRxDisconnectFilter 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.62
The time the received signaling state must be equal to the idle state to disconnect the voice call. Zero value disables idle state disconnect and maintains the voice call in the answered state.Time is entered in minutes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..5  

cdx6500VoiceCfgTransparentSignalingBusyoutState 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.63
The received signalling state that represents the Busyout state. For E1 ports and T1 ESF ports, these bits represent the ABCD signalling bits on the interface.For E&M analog ports, Offhook is assumed for the busyout/alarm state. The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0000FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.64
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1000FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.65
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0100FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.66
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1100FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.67
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0010FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.68
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1010FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.69
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0110FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.70
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1110FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.71
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0001FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.72
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1001FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.73
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0101FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.74
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1101FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.75
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0011FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.76
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1011FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.77
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo0111FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.78
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgXlateSigInfo1111FromRemoteToLocalPort 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.79
Translate the signalling information received from the remote end to a value to be transmitted out the local port.If the local port is a T1/ESF or E1 port enter the ABCD values, for a T1/SF port, enter the AB(AB) value. If the local port is an analog E&M port, enter 0000 for idle (Onhook) and 1111 for active (Offhook). The range is 0000 to 1111.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

cdx6500VoiceCfgDialToneLowerFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.80
The lower of the two frequencies needed to generate the dial tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgDialToneLowerFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.81
The amplitude of the lower frequency to generate the dial tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgDialToneUpperFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.82
The higher of the two frequencies needed to generate the dial tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgDialToneUpperFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.83
The amplitude of the upper frequency to generate the dial tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgRingBackToneLowerFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.84
The lower of the two frequencies needed to generate the Ringback tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgRingBackToneLowerFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.85
The amplitude of the lower frequency to generate the Ringback tone. To be specified in steps of 0.5dB, -30dB turn off output.The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgRingBackToneUpperFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.86
The higher of the two frequencies needed to generate the Ring-back tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgRingBackToneUpperFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.87
The amplitude of the upper frequency to generate the Ringback tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgBusyToneLowerFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.88
The lower of the two frequencies needed to generate the Busy tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgBusyToneLowerFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.89
The amplitude of the lower frequency to generate the Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgBusyToneUpperFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.90
The higher of the two frequencies needed to generate the Busy tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgBusyToneUpperFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.91
The amplitude of the upper frequency to generate the Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgTxBusyToneOffTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.92
Timer for the Busy tone off state. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1000  

cdx6500VoiceCfgTxBusyToneOnTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.93
Timer for the busy tone on state. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1000  

cdx6500VoiceCfgFastBusyToneLowerFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.94
The lower of the two frequencies needed to generate the Fast Busy tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgFastBusyToneLowerFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.95
The amplitude of the lower frequency to generate the Fast Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgFastBusyToneUpperFrequency 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.96
The higher of the two frequencies needed to generate the Fast Busy tone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 200..3500  

cdx6500VoiceCfgFastBusyToneUpperFrequencyAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.97
The amplitude of the upper frequency to generate the Fast Busy tone. To be specified in steps of 0.5dB, -30dB turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgTxFastBusyToneOffTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.98
Timer for the Fast Busy tone off state. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1000  

cdx6500VoiceCfgTxFastBusyToneOnTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.99
Timer for the Fast Busy tone on state. Granularity is 50 milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..1000  

cdx6500VoiceCfgHybridFXO 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.100
Hybrid balance filters. sixHundred : 600 ohm interface. adaptive : 600 ohm with adaptive filter. nc : Skipped during configuration. This parameter is displayed for DSPM/HC (FXO) and skipped for DSPM/E&M, DSPM/FXS and all virtual port types.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER sixHundred(1), adaptive(11), nc(100)  

cdx6500VoiceCfgTxPulse 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.101
The width of the transmitted Seizure, PTS, or Answer pulse in msec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 50..200  

cdx6500VoiceCfgRxMinPulse 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.102
The minimum pulse width to declare a valid received Seizure, PTS, or Answer pulse.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 50..200  

cdx6500VoiceCfgRxMaxPulse 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.103
The maximum pulse width to declare a valid received Seizure, PTS, or Answer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 50..200  

cdx6500VoiceCfgTxMasterClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.104
The width of the transmitted Master Clear-Forward, Clear-Back, or Release Guard pulse in msec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgRxMinMasterClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.105
The minimum pulse width to declare a valid received Master Clear-Forward, Clear-Back, or Release Guard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgRxMaxMasterClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.106
The maximum pulse width to declare a valid received Master Clear-Forward, Clear-Back, or Release Guard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgTxSlaveClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.107
The width of the transmitted Slave Clear-Forward or Clear-Back pulse in msec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgRxMinSlaveClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.108
The minimum pulse width to declare a valid received Slave Clear-Forward or Clear-Back.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgRxMaxSlaveClear 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.109
The maximum pulse width to declare a valid received Slave Clear-Forward or Clear-Back.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 400..2000  

cdx6500VoiceCfgTxSlaveRelease 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.110
The width of the transmitted Slave Release Guard pulse in msec.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgRxMinSlaveRelease 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.111
The minimum pulse width to declare a valid received Slave Release Guard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgRxMaxSlaveRelease 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.112
The maximum pulse width to declare a valid received Slave Release Guard.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgTxPTSTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.113
The time delay from receiving a valid Seizure from the PBX to start transmitting a PTS pulse.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgRxPTSTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.114
The maximum time to wait for a PTS pulse from the PBX after sending a Seizure before giving up and clearing the trunk.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgMasterGuard 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.115
The time the master side waits in the guard state after transmitting a clear pulse.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgSlaveGuard 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.116
The time the slave side waits in the guard state after transmitting a clear pulse.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2000  

cdx6500VoiceCfgTxFlashHookTime 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.117
The lenght of time a flash signal will be transmitted as a result of a flash-hook from the remote interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..10000  

cdx6500VoiceCfgDtmfAmplitude 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.118
The amplitude of the DTMF digits. To be specified in steps of 0.5dB, -30.0 turn off output. The range is from -30dBm to -3dBm.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCfgFXSOffhookFilter 1.3.6.1.4.1.449.2.1.2.1.1.25.1.1.119
This is the amoung of time a valid OFFHOOK conidtion must be present before an analog FXS will declare OFFHOOK.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 20..500  

cdx6500GGCTVoiceSwitchTable 1.3.6.1.4.1.449.2.1.2.2.21.1
This table contains the Voice Switch Table configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500VoiceSwitchEntry

cdx6500VoiceSwitchEntry 1.3.6.1.4.1.449.2.1.2.2.21.1.1
Each entry contains a list of parameters that makeup the Voice Switch Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500VoiceSwitchEntry  

cdx6500VoiceSwitchRxDTMFDigitString 1.3.6.1.4.1.449.2.1.2.2.21.1.1.1
Select the voice number plans for the 6520/6560 network. The received DTMF digits received by the voice interface is compared to this parameter. - Enter a trailing asterisk(*) as a wild-card. - Use the space bar to blank the parameter. Range: 1 to 20 characters (valid characters are 0 through 9, '-', ',', '/', and '*'). The characters '-', ',', and '/' are allowed only for ease of reading. They are not sent to the remote port. Note: The maximum number of digits that can be sent to the remote end is 16.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500VoiceSwitchNumRxDigitToReceive 1.3.6.1.4.1.449.2.1.2.2.21.1.1.2
Select the number of DTMF digits to be received before making the call request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..20  

cdx6500VoiceSwitchCallParam 1.3.6.1.4.1.449.2.1.2.2.21.1.1.3
Define the network address of the called node and the port or Hunt Group number of the desired destination port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500VoiceSwitchAlternateDestination 1.3.6.1.4.1.449.2.1.2.2.21.1.1.4
This object is no longer supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER deprecatedObj(1)  

cdx6500VoiceSwitchCompressionOverrideRate 1.3.6.1.4.1.449.2.1.2.2.21.1.1.5
Select the voice compression override algorithm. none - No override, use port configured value. c8k - 8k CVSELP c16k - 16k CVSELP cB8k - Bundled 8k CVSELP cB16k - Bundled 16k CVSELP cE8Kb - Enhanced Bundled 8k CVSELP cE8Kb - Enhanced Bundled 16k CVSELP nc - Skipped during configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(6), cD8K(7), cD16K(8), cBD8K(10), cBD16K(11), cE8Kb(14), cE16Kb(15), nc(100)  

cdx6500VoiceSwitchNumLeadingDigitToStrip 1.3.6.1.4.1.449.2.1.2.2.21.1.1.6
Select the number of leading digits to be stripped off the received digits stream before sending the digits stream to the remote port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..20  

cdx6500VoiceSwitchPreFixDigits 1.3.6.1.4.1.449.2.1.2.2.21.1.1.7
Select digits to be added in front of or at the end of the received stream (after the stripped digits are removed) before sending the digit stream to the remote port. Range: 1 to 20 characters (valid characters are 0 through 9, '*', '#', 'R', 'P', and '-'). The character '-' is allowed only for ease of reading. It is not sent to the remote port. The 'P' character is used to indicate a pause is required in the playout of the digits at the remote end. The length of the pause is equal to 'Tx Interdigit Pause Time' as defined at the called port (destination port). Leading 'P' characters are not supported. The character 'R' is used to separate the prefix digit string from the postfix digit string Note: The maximum number of digits that can be sent to the remote end is 16.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500VoiceSwitchPostFixDigits 1.3.6.1.4.1.449.2.1.2.2.21.1.1.8
Select DTMF digits to be added at the end of the received DTMF stream before sending the digit stream to the remote port. Range: 1 to 20 characters (valid characters are 0 through 9, '-', ',', '/', '*', '#', and 'P'). The characters '-', ',', and '/' are allowed only for ease of reading. They are not sent to the remote port. The 'P' character is used to indicate a pause is required in the playout of the digits at the remote end. The length of the pause is equal to 'Tx Interdigit Pause Time' as defined at the called port (destination port). Note: The maximum number of digits that can be sent to the remote end is 16. This object is no longer supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

cdx6500VoiceSwitchEntryNumber 1.3.6.1.4.1.449.2.1.2.2.21.1.1.9
This is the entry number in the Voice Switch Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500PPSTVoicePortTable 1.3.6.1.4.1.449.2.1.3.1.1.26.1
This table contains the port statistics for Voice ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTVoicePortEntry

cdx6500PPSTVoicePortEntry 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1
A Voice Port Statistics Table Entry. Each entry contains the statistics for a single Voice Port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTVoicePortEntry  

cdx6500VoiceStatsPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.1
Port number of the Voice Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500VoiceStatsPortInterfaceType 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.2
This parameter indicates the type of DPSM card used. eAndM2 : DPSM/E&M. eAndM4 : DPSM/E&M. fxo : DPSM/HC(FXO). fxs : DPSM/FXS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER eAndM2(1), eAndM4(2), fxo(3), fxs(4)  

cdx6500VoiceStatsHWRevAndPartNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.3
Hardware revision and part number of the main card. The revision number has format n.n and the part number is an 8 digit number of the form nnnnnnnn.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsFortyEightVolts 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.4
This parameter indicates whether the 48 volt power supply is installed in the node. none : power supply not installed. present : power supply installed. na : Value not available. This parameter will not be displayed for DSPM/HC.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), present(2), na(100)  

cdx6500VoiceStatsPortState 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.5
This parameter indicates ths status of the port. disabled : The port is disabled. enabled : The port is enabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

cdx6500VoiceStatsCircuitState 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.6
This parameter indicates the state of the SVC associated with this port. connected : SVC established. disconnected : SVC not established.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connected(1), disconnected(2)  

cdx6500VoiceStatsCurrentMode 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.7
This parameter indicates the current operating mode of the DSP. voice : DSP is currently operating in voice mode. pcm : PCM mode is not supported. fax : DSP is currently operating in fax mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER voice(1), pcm(2), fax(3)  

cdx6500VoiceStatsTimeOfLastStatReset 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.8
This parameter indicates the time since the last statistic reset using the format month:day:year:hours:minutes:seconds (mm:dd:yyyy:hh:mm:ss).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.9
This parameter indicates the duration of the current (last) call using the format hours:minutes:seconds (hh:mm:ss).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsTotalCallDuration 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.10
This parameter indicates the total time of all calls since last reset.It is measured from Offhook to Onhook and uses the format hours:minutes:seconds (hh:mm:ss).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsPortUtilization 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.11
This parameter is calculated as the ratio of `Total Call Duration' to `Time Of Last Reset'. It is a percentage value of the form nnn%.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500VoiceStatsNumberOfCalls 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.12
This parameter indicates the total number of calls since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsLastDigitsTransmitted 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.13
This parameter indicates the last DTMF digits transmitted to the voice interface. Not supported at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsLastDigitsReceived 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.14
This parameter indicates the last DTMF digits received from the voice interface. Not supported at this time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsTxPacketDropped 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.15
This parameter indicates the number of times transmit packets were dropped due to DSPM congestion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsRxPacketDropped 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.16
This parameter indicates the number of times receive packets were dropped due to network overload or processor loading.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsDroppedPackets 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.17
This parameter indicates the estimate of packets dropped end to end in the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsDSPInternalFaults 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.18
This parameter indicates the number of recoverable software faults.It is displayed only when the DEBUG flag is set.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsTxPackets 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.19
This parameter indicates the number of packets received from the network port since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsRxPackets 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.20
This parameter indicates the number of packets sent to the network port since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsTxPacketsPerSecond 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.21
This parameter indicates the average number of packets transmitted per second.It is calculated as the ratio of `Tx Packets' to `Total Call Duration'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsRxPacketsPerSecond 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.22
This parameter indicates the average number of packets received per second.It is calculated as the ratio of `Rx Packets' to `Total Call Duration'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500VoiceStatsDSIEfficiency 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.23
This parameter is calculated by dividing `Rx Packets/sec' by the packet rate. It is a percentage value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500VoiceStatsCurrentRate 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.24
This parameter indicates the current compression rate being used. cD8K : Compression rate is 8K. cBD8K : Compression rate is bundled 8K. cE8Kb : Compression rate is Enhanced bundled D8K. cD16K : Compression rate is 16K. cBD16K : Compression rate is bundled 16K. cE16Kb : Compression rate is Enhanced bundled D16K. cPcm : Compression rate is PCM. cFax : Compression rate is FAX. na : Value not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cD8K(1), cBD8K(2), cE8Kb(3), cD16K(4), cBD16K(5), cE16Kb(6), cPcm(7), cFax(8), na(100)  

cdx6500VoiceStatsInputPower 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.25
This parameter indicates the input power level in dBm. (Measured power).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsOutputPower 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.26
This parameter indicates the output power level in dBm. (Measured power).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsFAXTransmissions 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.27
This parameter indicates the number of FAX transmissions spoofed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500VoiceStatsUnsupportedFmtsFAXXmissions 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.28
This parameter indicates the number of FAX transmissions requesting unsupported formats but transmitted using ISG formats.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500PPSTSignalingSequenceTrapTxState 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.29
The transmitting voice signalling state is displayed as ABCD (i.e. 1010). This object is no longer supported. Refer to cdx6500SignalingSequenceTrapTxState.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500PPSTSignalingSequenceTrapRxState 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.30
The receiving voice signalling state is displayed as ABCD (i.e. 1010). This object is no longer supported. Refer to cdx6500SignalingSequenceTrapRxState.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500PPSTSignalingSequenceTrapMachineState 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.31
The voice signalling state machine state is a 11 character field representing the state of the signalling software. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapMachineState.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(11)  

cdx6500PPSTSignalingSequenceTrapTimeSinceLastChange 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.32
This parameter indicates the time from the previous state to this state, measured in milliseconds. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapTimeSinceLastChange.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500PPSTSignalingSequenceTrapComment 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.33
The comment field is an ASCII string upto 16 characters long. This object is no longer supported. Refer to cdx6500SignalingSequenceTrapComment.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500VoiceStatsCurrentStatus 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.34
This is the call processing state machine status. inhibited : Current Status = Disconnected. disconnected : Current Status = Disconnected. calling : Current Status = Calling. called : Current Status = Called. connected : Current Status = Connected (data transfer). null : Current Status = Undefined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inhibited(1), disconnected(2), calling(3), called(4), connected(5), null(6)  

cdx6500VoiceStatsLastClearCauseCode 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.35
This parameter indicates the last clear cause code received Every code corresponds to an integer value followed by its text description in paranthesis. eg.Consider the clear cause code for `number busy' which is CAUSE-CLR-NUM-BSY. This corresponds to : 001 (number busy).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsLastClearDiagnosticCode 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.36
This parameter indicates the last clear diagnostic received.Every code corresponds to an integer value followed by its text description in paranthesis. eg.Consider the diagnostic code for `invalid bits in packet' which is DIAG-INV-PKT-BITS.This corresponds to :041 (invalid bits in packet).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsLastInboundCallPacketCalledAddress 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.37
This parameter contains the called address present in the last inbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..15)  

cdx6500VoiceStatsLastInboundCallPacketCallingAddress 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.38
This parameter contains the calling address present in the last inbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..15)  

cdx6500VoiceStatsLastInboundCallPacketFacilities 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.39
This parameter contains the facilities present in the last inbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..105)  

cdx6500VoiceStatsLastInboundCallPacketCUD 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.40
This parameter contains the call user data present in the last inbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500VoiceStatsLastOutboundCallPacketCalledAddress 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.41
This parameter contains the called address present in the last outbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..15)  

cdx6500VoiceStatsLastOutboundCallPacketCallingAddress 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.42
This parameter contains the calling address present in the last outbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(3..15)  

cdx6500VoiceStatsLastOutboundCallPacketFacilities 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.43
This parameter contains the facilities present in the last outbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..105)  

cdx6500VoiceStatsLastOutboundCallPacketCUD 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.44
This parameter contains the call user data present in the last outbound call packet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500VoiceStatsRingerStatus 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.45
This parameter indicates the Ringer status on the board. It is displayed only for DSPM/FXS interfaces. rs25Hz : 25Hz Ringer status on board. rs50Hz : 50Hz Ringer status on board. na : Value not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rs25Hz(1), rs50Hz(2), na(100)  

cdx6500VoiceStatsDSPMSMSlotNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.46
This parameter indicates the slot of the DSPM/SM. It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..99  

cdx6500VoiceStatsDSPMNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.47
This parameter indicates the DSP used for the virtual port.It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..4  

cdx6500VoiceStatsT1E1PortNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.48
This is the port number of the T1 or E1 port this voice channel is on.It is displayed only for DSPM/SM interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500VoiceStatsTimeSlotNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.49
This parameter indicates the time slot number. It is displayed only for DSPM/SM interfaces. For multiple time slots it will be displayed as 1,2-5,..
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsDaughterCardRevAndPartNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.50
Hardware revision and part number of the daughter card.The revision number has format n.n and the part number is an 8 digit number of the form nnnnnnnn.It is displayed only for DSPM/HC interfaces.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsVADEfficiency 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.51
VAD (Voice Activity Detection) Efficiency shows you the percentage of VAD efficiency. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500VoiceStatsMeanDelayDeviation 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.52
This parameter shows you Mean Delay Deviation. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500VoiceStatsMaxDelayDeviation 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.53
This parameter shows you Max Delay Deviation in the way of Max Delay Deviation/Max Delay Dev Highwater. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceStatsPktRecResync 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.54
This parameter shows you Receiver Resets. It is displayed only for DSPM/FX interfaces. A value of 0 indicates that this parameter is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500VoiceCallStatsNoPacketDropped 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.55
It is the number of dropped packet occurred during the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsNoCallsDropped 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.56
It is the number of dropped calls occurred during the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason0 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.57
It is the number of dropped cause code 0, [originated by DTE; no info], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason1 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.58
It is the number of dropped cause code 1, [number busy], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason3 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.59
It is the number of dropped cause code 3, [invalid facility request], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason5 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.60
It is the number of dropped cause code 5, [network congestion], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason9 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.61
It is the number of dropped cause code 9, [out of order], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason11 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.62
It is the number of dropped cause code 11, [access barred], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason13 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.63
It is the number of dropped cause code 13, [not obtainable], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason17 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.64
It is the number of dropped cause code 17, [remote procedure error], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason19 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.65
It is the number of dropped cause code 19, [local procedure error], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason21 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.66
It is the number of dropped cause code 21, [RPOA out of order], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason33 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.67
It is the number of dropped cause code 33, [incompatible destination], upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500VoiceCallStatsDroppedReason-Rest 1.3.6.1.4.1.449.2.1.3.1.1.26.1.1.68
It is the number of the rest of dropped cause codes upto the last 24 hours.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500PPSTSignalingSequenceTrapTable 1.3.6.1.4.1.449.2.1.3.1.1.26.2
A table containing the Signaling Sequence Trap entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTSignalingSequenceTrapEntry

cdx6500PPSTSignalingSequenceTrapEntry 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1
An entry in the Signaling Sequence Trap table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTSignalingSequenceTrapEntry  

cdx6500SignalingSequenceTrapPortNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.1
Port number of the Voice Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500SignalingSequenceTrapEventNumber 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.2
Event number in the Signaling Sequence Trap Entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..32  

cdx6500SignalingSequenceTrapTxState 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.3
The transmitting voice signalling state is displayed as ABCD (i.e. 1010).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500SignalingSequenceTrapRxState 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.4
The receiving voice signalling state is displayed as ABCD (i.e. 1010).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500SignalingSequenceTrapMachineState 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.5
The voice signalling state machine state is a 11 character field representing the state of the signalling software.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(11)  

cdx6500SignalingSequenceTrapTimeSinceLastChange 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.6
This parameter indicates the time from the previous state to this state, measured in milliseconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500SignalingSequenceTrapComment 1.3.6.1.4.1.449.2.1.3.1.1.26.2.1.7
The comment field is an ASCII string upto 16 characters long.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500StatVCSTable 1.3.6.1.4.1.449.2.1.3.4.4
This table is showing the Voice Call Statistics in a node that would allow a user to determine current and past perfrmance.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500StatVCSEntry

cdx6500StatVCSEntry 1.3.6.1.4.1.449.2.1.3.4.4.1
A list of objects describing a single VCS.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500StatVCSEntry  

cdx6500StatVCSIndex 1.3.6.1.4.1.449.2.1.3.4.4.1.1
It is time position in the list of VCS's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500StatVCSTime 1.3.6.1.4.1.449.2.1.3.4.4.1.2
It is displaying the corresponding time to index in the list of VCS's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500StatVCSNoPacketDropped 1.3.6.1.4.1.449.2.1.3.4.4.1.3
It is the number of dropped packet occurred during the time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500StatVCSNoCallsDropped 1.3.6.1.4.1.449.2.1.3.4.4.1.4
It is the number of dropped calls occurred during the time.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500StatVCSDroppedReasons 1.3.6.1.4.1.449.2.1.3.4.4.1.5
It is the number of 12 possible reasons from x25-causes. (Rsn0/Rsn1/Rsn3/Rsn5/Rsn9/Rsn11/Rsn13/Rsn17/Rsn19/Rsn21/Rsn33/Rsn-Rest)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500StatVCSNoCallsProcessed 1.3.6.1.4.1.449.2.1.3.4.4.1.6
It is the number of all voice calls processed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500StatVCSPercentPeakAvgCurOfCPULoad 1.3.6.1.4.1.449.2.1.3.4.4.1.7
It is the value of Peak, Average and Currentof CPU load in percent. (Peak/Avg/Cur)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500StatVCSPercentPeakAvgCurOfDataBuf 1.3.6.1.4.1.449.2.1.3.4.4.1.8
It is the value of Peak, Average and Current of Data Buffer in percent. (Peak/Avg/Cur)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cdx6500StatVCSPercentPeakAvgCurOfIORBBuf 1.3.6.1.4.1.449.2.1.3.4.4.1.9
It is the value of Peak, Average and Current of IORB Buffer in percent. (Peak/Avg/Cur)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString