VIDEOFRAME-SIGMON-MIB

File: VIDEOFRAME-SIGMON-MIB.mib (18560 bytes)

Imported modules

RFC1155-SMI SNMPv2-SMI SNMPv2-TC
SNMPv2-CONF VIDEOFRAME-REGISTRATIONS-MIB VIDEOFRAME-GENERIC-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY OBJECT-IDENTITY
NOTIFICATION-TYPE Integer32 IpAddress
DisplayString RowStatus MODULE-COMPLIANCE
OBJECT-GROUP vfProducts vfProductsReg
vfMIBModules vfBoxId

Defined Types

VfFrameSlotEntry  
SEQUENCE    
  vfFrameSlotNumber INTEGER
  vfFrameSlotStatus INTEGER
  vfModuleTypeRegObjectID OBJECT IDENTIFIER
  vfModuleTypeRootOID OBJECT IDENTIFIER
  vfModulePartNo DisplayString
  vfModuleDescription DisplayString
  vfModuleTrapEnable INTEGER
  vfModuleAlarmAutoReArm INTEGER

VfDerivedNotificationEntry  
SEQUENCE    
  vfDnFunctionNumber Integer32
  vfDnFunctionDescription DisplayString
  vfDnNotificationLevel INTEGER
  vfDnNotificationEnable INTEGER
  vfDnNotificationAutoReArm INTEGER
  vfDnNotificationState INTEGER
  vfDnNotificationAcknowledge INTEGER

Defined Values

videoframeSigmonMIB 1.3.6.1.4.1.4596.6.1.3
This MIB describes the device specific objects of the Videoframe Signal Monitoring Frame, and augments MIB-2 and VF-GENERIC in the identification of this Videoframe Systems managed device. This module will be extended, or modified as required. Videoframe Systems reserves the right to make changes in specification and other information contained in this document without prior notice. The reader should consult Videoframe Systems to determine whether any such changes have been made. In no event shall Videoframe Systems be liable for any incidental, indirect, special, or consequential damages whatsoever (including but not limited to lost profits) arising out of or related to this document or the information contained in it. Videoframe Systems grants vendors, end-users, and other interested parties a non-exclusive license to use this specification in connection with the management of Videoframe Systems products. Copyright 2001 Videoframe, Inc.
MODULE-IDENTITY    

vfProductsSignalMonitoringFrameReg 1.3.6.1.4.1.4596.6.2.4
Videoframe signal monitoring frame with hot-swappable modules, and monitoring via SNMP and gvg modular protocol.
Status: current Access: read-only
OBJECT-IDENTITY    

vfProductsVF200Reg 1.3.6.1.4.1.4596.6.2.5
VF200 2RU modular frame for Signal Monitoring and machine control functions.
Status: current Access: read-only
OBJECT-IDENTITY    

vfSigmonFrame 1.3.6.1.4.1.4596.4.2
OBJECT IDENTIFIER    

vfSigmonFrameModuleTypes 1.3.6.1.4.1.4596.4.2.1
OBJECT IDENTIFIER    

vfSigmonFrameEvents 1.3.6.1.4.1.4596.4.2.8
OBJECT IDENTIFIER    

vfSigmonFrameEventsV2 1.3.6.1.4.1.4596.4.2.8.0
OBJECT IDENTIFIER    

vfSigmonFrameDerivedEvents 1.3.6.1.4.1.4596.4.2.9
OBJECT IDENTIFIER    

vfSigmonFrameDerivedEventsV2 1.3.6.1.4.1.4596.4.2.9.0
OBJECT IDENTIFIER    

vfFrameSlotTable 1.3.6.1.4.1.4596.4.2.2
Each row contains information about one slot in the managed VF200 frame.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VfFrameSlotEntry

vfFrameSlotEntry 1.3.6.1.4.1.4596.4.2.2.1
Information about one slot in the managed VF200 frame.
Status: current Access: not-accessible
OBJECT-TYPE    
  VfFrameSlotEntry  

vfFrameSlotNumber 1.3.6.1.4.1.4596.4.2.2.1.1
Slot number in frame.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..12  

vfFrameSlotStatus 1.3.6.1.4.1.4596.4.2.2.1.2
State of this slot. Illegal means the slot does not exist. moduleValid means the correct firmware has been loaded to the module and it is ready for operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER empty(1), moduleUninitialized(2), moduleValid(3), illegalSlot(4)  

vfModuleTypeRegObjectID 1.3.6.1.4.1.4596.4.2.2.1.3
MIB-registered identification of the module currently installed in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

vfModuleTypeRootOID 1.3.6.1.4.1.4596.4.2.2.1.4
Root OID of the module-specific managed information for the module currently installed in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

vfModulePartNo 1.3.6.1.4.1.4596.4.2.2.1.5
Videoframe part no. of module currently installed in slot - should match module nameplate.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

vfModuleDescription 1.3.6.1.4.1.4596.4.2.2.1.6
Description of module currently installed in slot - should match module nameplate.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

vfModuleTrapEnable 1.3.6.1.4.1.4596.4.2.2.1.7
Enables or disables the Trap that is associated with a slot status change event or module event.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

vfModuleAlarmAutoReArm 1.3.6.1.4.1.4596.4.2.2.1.8
Enables or disables automatic re-arming of alarms from signal monitoring modules.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

vfFrameOfflineSwitch 1.3.6.1.4.1.4596.4.2.3
Indicates the state of the 'offline' switch for the frame. 'offline' indicates the switch is set to take the frame offline.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER online(1), offline(2)  

vfFrameLocateIndicator 1.3.6.1.4.1.4596.4.2.4
Set to flash (1) to cause the locate LED on the front of the frame to begin flashing. Set to off to stop flashing. This is used to verify the identity of a particular unit among racks of units.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER flash(1), off(2)  

vfFrameAdminState 1.3.6.1.4.1.4596.4.2.5
The desired operational state of this device. Use this object to command the frame to a different operational state (vfBoxState from the vf-generic MIB module). NOTE: It is mandatory that a managed device support all of the enumerated device states. vfFrameOnline(1) - The device is running and ready to process load. vfFrameInMaintenance(2) - The device is online, but either the device as a whole, or one or more of its components are in maintenance mode. Maintenance mode could be described as a mode where diagnostics are being run on the device, or some tasks such as device configuration are being excuted on the device that has inhibited its normal operation. vfFrameDisabled(3) - The device has been explicitly disabled from its normal mode of operation, such as when selected as the backup of a redundant pair. vfFrameResetting(4) - The device is in a reset cycle. Any information collected, or dynamic configuration of the device prior to this state may be lost.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vfFrameOnline(1), vfFrameInMaintenance(2), vfFrameDisabled(3), vfFrameResetting(4)  

vfNumDerivedNotifications 1.3.6.1.4.1.4596.4.2.6
Number of derived notifications defined in vf200 configuration file for this unit. Gives size of derived notifications table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

vfDerivedNotificationTable 1.3.6.1.4.1.4596.4.2.7
Each row contains information about one derived notification defined for the managed VF200 frame.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VfDerivedNotificationEntry

vfDerivedNotificationEntry 1.3.6.1.4.1.4596.4.2.7.1
A row in the derived notification table.
Status: current Access: not-accessible
OBJECT-TYPE    
  VfDerivedNotificationEntry  

vfDnFunctionNumber 1.3.6.1.4.1.4596.4.2.7.1.1
Derived Notification Function Number. Identifies derived notification function, define in frame config. file.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

vfDnFunctionDescription 1.3.6.1.4.1.4596.4.2.7.1.2
Derived Notification Description. Describes derived notification function for the operator. Set in frame config. file.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..120)  

vfDnNotificationLevel 1.3.6.1.4.1.4596.4.2.7.1.3
Notification level for this derived notification. selects which trap will be sent for the notification, out of four possible.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER levelA(1), levelB(2), levelC(3), levelD(4)  

vfDnNotificationEnable 1.3.6.1.4.1.4596.4.2.7.1.4
Use to enable or disable this derived notification function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

vfDnNotificationAutoReArm 1.3.6.1.4.1.4596.4.2.7.1.5
Use to enable or disable automatic re-arming of this derived notification function. Auto re-arming allows multiple unacknowledged activations of the derived notification. It re-arms the function after notification so that the specified alarms are again monitored according to the logic function.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

vfDnNotificationState 1.3.6.1.4.1.4596.4.2.7.1.6
The current state of this derived notification function.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ready(1), triggered(2)  

vfDnNotificationAcknowledge 1.3.6.1.4.1.4596.4.2.7.1.7
Use to acknowledge a derived notification. If notificationAutoReArm is disabled, this will re-arm the notification. Otherwise, it is automatically re-armed, and this object is not used.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER idle(1), unacknowledged(2), acknowledge(3)  

vfFrameSlotStatusChange 1.3.6.1.4.1.4596.4.2.8.0.1
A slot status change occurred.
Status: current Access: read-write
NOTIFICATION-TYPE    

derivedNotificationLevelA 1.3.6.1.4.1.4596.4.2.9.0.1
A LevelA derived notification was triggered.
Status: current Access: read-write
NOTIFICATION-TYPE    

derivedNotificationLevelB 1.3.6.1.4.1.4596.4.2.9.0.2
A LevelB derived notification was triggered.
Status: current Access: read-write
NOTIFICATION-TYPE    

derivedNotificationLevelC 1.3.6.1.4.1.4596.4.2.9.0.3
A LevelC derived notification was triggered.
Status: current Access: read-write
NOTIFICATION-TYPE    

derivedNotificationLevelD 1.3.6.1.4.1.4596.4.2.9.0.4
A LevelD derived notification was triggered.
Status: current Access: read-write
NOTIFICATION-TYPE