UB-MIB-SUPRV

File: UB-MIB-SUPRV.mib (92905 bytes)

Imported modules

RFC1065-SMI RFC1155-SMI RFC1158-MIB
RFC1213-MIB

Imported symbols

Counter IpAddress OBJECT-TYPE
enterprises Counter TimeTicks
DisplayString ifIndex PhysAddress

Defined Types

A1gEntry  
SEQUENCE    
  a1gSlotId INTEGER
  a1gPorts INTEGER
  a1gOperStatus INTEGER
  a1gTempStatus INTEGER
  a1gEthBusAdmAction INTEGER
  a1gEthBusMgmtStatus INTEGER
  a1gNetMgmtBusOperStatus INTEGER
  a1gProductType INTEGER
  a1gUpTime TimeTicks
  a1gResets Counter
  a1gResetAction INTEGER

ConfigEntry  
SEQUENCE    
  configSlotId INTEGER
  configFaultActionType INTEGER
  configRetries INTEGER
  configPowerUpMode INTEGER

A1imEntry  
SEQUENCE    
  a1imSlotId INTEGER
  a1imMACAddr PhysAddress
  a1imPodDiagnosticMsg DisplayString
  a1imModuleFault INTEGER
  a1imHaltReason INTEGER
  a1imDebugRegisters OCTET STRING

TplEntry  
SEQUENCE    
  tplSlotId INTEGER
  tplIPAddress IpAddress
  tplNiuName DisplayString
  tplProtocolType INTEGER
  tplSuprvPollStatus INTEGER

ImenEthBusEntry  
SEQUENCE    
  imenSlotId INTEGER
  imenTransmitPkts Counter
  imenReceivePkts Counter
  imenCRCErrors Counter
  imenCollisions Counter

BrdgEntry  
SEQUENCE    
  brdgSlotId INTEGER
  brdgIfId INTEGER
  brdgIfType INTEGER
  brdgIfFault INTEGER
  brdgIfMACAddr PhysAddress

EcEntry  
SEQUENCE    
  ecSlotId INTEGER
  ecCarrierCounter Counter
  ecFanStatus INTEGER

NetEntry  
SEQUENCE    
  netSlotId INTEGER
  netBackboneType INTEGER
  netFault INTEGER
  netBackboneStatus INTEGER

BrnEntry  
SEQUENCE    
  brnSlotId INTEGER
  brnIfId INTEGER
  brnIfEthDLCStatus INTEGER
  brnCarrierCounter Counter
  brnCarrierTimeInterval TimeTicks
  brnTransmitPkts Counter
  brnReceivePkts Counter
  brnCRCErrors Counter
  brnCollisions Counter
  brnPktsAborted16Colls Counter
  brnShortPkts Counter
  brnAlignmentErrors Counter
  brnOverflows Counter
  brnUnderflows Counter

Tr16cEntry  
SEQUENCE    
  tr16cSlotId INTEGER
  tr16cTier INTEGER
  tr16cOperState INTEGER
  tr16cRingNumber INTEGER
  tr16cManufacturerID OCTET STRING
  tr16cManufacturerProductID DisplayString
  tr16cManufProductVers OCTET STRING
  tr16cActiveMonitorPortNumber INTEGER
  tr16cRingSpeed INTEGER
  tr16cLLCFrames Counter
  tr16cMACFrames Counter
  tr16cOctets Counter
  tr16cMulticastFrames Counter
  tr16cBroadcastFrames Counter
  tr16cFrameCheckSequences Counter
  tr16cAutoPartitionEnableTimer TimeTicks
  tr16cAutoPartitionHoldTimer TimeTicks
  tr16cAutoPartitionRetries INTEGER
  tr16cLLCSamples Counter
  tr16cMACSamples Counter
  tr16cUpTimeMS Counter
  tr16cResetDurableUserAttrs INTEGER

Tr16reEntry  
SEQUENCE    
  tr16reSlotId INTEGER
  tr16reLostFrames Counter
  tr16reRcvCongestionErrors Counter
  tr16reFrequencyErrors Counter
  tr16reFrameCopyErrors Counter
  tr16reTokenErrors Counter

EcpEntry  
SEQUENCE    
  ecpSlotId INTEGER
  ecpPortId INTEGER
  ecpMgmtStatus INTEGER
  ecpAdmAction INTEGER
  ecpCarrierCounter Counter

EcfpEntry  
SEQUENCE    
  ecfpSlotId INTEGER
  ecfpPortId INTEGER
  ecfpMACAddr PhysAddress
  ecfpTxIdleTime TimeTicks

Ec10btpEntry  
SEQUENCE    
  ec10btpSlotId INTEGER
  ec10btpPortId INTEGER
  ec10btpLinkTestStatus INTEGER
  ec10btpLinkTestAction INTEGER

TrcpEntry  
SEQUENCE    
  trcpSlotId INTEGER
  trcpPortId INTEGER
  trcpAdmAction INTEGER
  trcpOperStatus INTEGER

Tr16p1Entry  
SEQUENCE    
  tr16p1SlotId INTEGER
  tr16p1PortId INTEGER
  tr16p1InsertionState INTEGER
  tr16p1AllowInsert INTEGER
  tr16p1ForceInsert INTEGER
  tr16p1PhantomState INTEGER

Tr16p2Entry  
SEQUENCE    
  tr16p2SlotId INTEGER
  tr16p2PortId INTEGER
  tr16p2OperState INTEGER
  tr16p2BeaconDetects Counter
  tr16p2LastSourceAddress PhysAddress
  tr16p2LLCFramesTransmitted Counter
  tr16p2LLCFramesReceived Counter
  tr16p2MACFramesTransmitted Counter
  tr16p2MACFramesReceived Counter
  tr16p2OctetsTransmitted Counter
  tr16p2OctetsReceived Counter
  tr16p2MulticastsTransmitted Counter
  tr16p2BroadcastsTransmitted Counter
  tr16p2FCSErrorsTransmitted Counter
  tr16p2FCSErrorsReceived Counter
  tr16p2LastSourceAddressUptime TimeTicks

Tr16p3Entry  
SEQUENCE    
  tr16p3SlotId INTEGER
  tr16p3PortId INTEGER
  tr16p3LineErrors Counter
  tr16p3InternalErrors Counter
  tr16p3Burst5Errors Counter
  tr16p3AcErrors Counter
  tr16p3AbortDelimiters Counter

TrpsbEntry  
SEQUENCE    
  trpsbIpAddress IpAddress
  trpsbCommunity OCTET STRING
  trpsbActions INTEGER

Defined Values

ubNode 1.3.6.1.4.1.75
OBJECT IDENTIFIER    

ubEquip 1.3.6.1.4.1.75.1
OBJECT IDENTIFIER    

ubTrapAttrs 1.3.6.1.4.1.75.3
OBJECT IDENTIFIER    

ubSystem 1.3.6.1.4.1.75.4
OBJECT IDENTIFIER    

ubSuprv 1.3.6.1.4.1.75.1.1
OBJECT IDENTIFIER    

hub 1.3.6.1.4.1.75.1.1.1
OBJECT IDENTIFIER    

card 1.3.6.1.4.1.75.1.1.2
OBJECT IDENTIFIER    

port 1.3.6.1.4.1.75.1.1.3
OBJECT IDENTIFIER    

ubSecurity 1.3.6.1.4.1.75.4.1
OBJECT IDENTIFIER    

hubId 1.3.6.1.4.1.75.1.1.1.1
HUB ENCLOSURE Group The address of the hub enclosure in MAC address format. This is the supervisor's MAC address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

hubType 1.3.6.1.4.1.75.1.1.1.2
The type of enclosure; the number of slots in the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER oneSlot-ASE1000(1), twoSlot-ASE2000(3), fiveSlot-ASE3000(5), elevenSlot-ASE7000(11)  

hubName 1.3.6.1.4.1.75.1.1.1.3
The name of the Access/One enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hubSerNumber 1.3.6.1.4.1.75.1.1.1.4
The serial number of the hub.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

hubIPAddr 1.3.6.1.4.1.75.1.1.1.5
The IP address used to communicate with the SNMP agent in the Supervisor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

hubPowerSupplyStatus 1.3.6.1.4.1.75.1.1.1.6
The power supply status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), normalPower(2), acPowerAbnormal(3), highTemp(4), onePsModuleFailed(5)  

hubTempStatus 1.3.6.1.4.1.75.1.1.1.7
Indicates whether the temperature of at least one card in the enclosure is out of range.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), abnormalTemperature(2), normalTemperature(3)  

hubPollTime 1.3.6.1.4.1.75.1.1.1.8
The time in tenths of seconds between polls of hub cards by the supervisor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), no-polling-requested(2), oneHalfSec(3), oneSec(4), onePt5secs(5), twoSecs(6), twoPt5secs(7), threeSecs(8), threePt5secs(9), fourSecs(10), fourPt5secs(11), fiveSecs(12)  

hubResetAction 1.3.6.1.4.1.75.1.1.1.9
When this internet-object is SET to a value of requested, resetAllCards, or forceLoad, the hub resets (according to the specific request), and after resetting locally sets the value of this internet-object to not-requested. Initially its value is not-requested.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER not-requested(2), resetAllCards(3), forceLoad(5)  

hubAFS 1.3.6.1.4.1.75.1.1.1.10
Indicates whether airflow inside the enclosure is normal. This applies only to enclosures with an Air Flow Sensor (AFS) installed and a supervisor capable of detecting the signal from this sensor (currently only the ASM-710 and ASM-760).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), normalAirflow(2), abnormalAirflow(3)  

ensupStaticNetConfig 1.3.6.1.4.1.75.1.1.2.1
CARD Group ensup: Ethernet Supervisor The configured status of the interface between the net module(s) and the backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER netAndSupDirect(2), supOnly(3), netOnly(4), supElseBridge(5)  

ensupDynamicNetStatus 1.3.6.1.4.1.75.1.1.2.2
The dynamically changed configuration status of the interface between the net module(s) and the backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), netAndSupDirect(2), supOnly(3), netOnly(4), bridgeOnly(5), netOrSupLoopback(6)  

ensupNetBridgeSlot 1.3.6.1.4.1.75.1.1.2.3
The relative group (slot) containing a local bridge by which the modules access the backbone (relevant only if the value of ensupStaticNetConfig is 'sup-bridge').
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), slot-1(2), slot-2(3), slot-3(4), slot-4(5), slot-5(6), slot-6(7), slot-7(8), slot-8(9), slot-9(10), slot-10(11), slot-11(12)  

ensupCarrierCounter 1.3.6.1.4.1.75.1.1.2.4
The number of times that carrier sense was on when sampled every 2 ms (used in conjunction with a1gUpTime).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ensupNetUtilization 1.3.6.1.4.1.75.1.1.2.5
The percentage of time that carrier sense was on; the percentage is expressed to the nearest tenth (as XXX.X%).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

ensupNetUtilThreshold 1.3.6.1.4.1.75.1.1.2.6
The threshold for ensupNetUtilization (sends a trap when exceeded).Percentage utilization to the nearest whole integer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a1gTable 1.3.6.1.4.1.75.1.1.2.7
a1g: Access/1 Group TABLE Row selection: the card's relative position in the enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A1gEntry

a1gEntry 1.3.6.1.4.1.75.1.1.2.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A1gEntry  

a1gSlotId 1.3.6.1.4.1.75.1.1.2.7.1.1
The card's relative position in the enclosure, starting at 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a1gPorts 1.3.6.1.4.1.75.1.1.2.7.1.2
The number of ports on a card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a1gOperStatus 1.3.6.1.4.1.75.1.1.2.7.1.3
states the module goes through when doing power-on diagnostics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), initializing(2), powerOnDiagnostics(3), debugMode(4), onlineDiagnostics(5), moduleFault(6), netBooting(7), netLoading(8), cbLoading(9), up(10), standby(11), softwareDisabled(12), reset(13), inactive(14), active(15), notResponding(16)  

a1gTempStatus 1.3.6.1.4.1.75.1.1.2.7.1.4
An indication whether the card's temperature is too high.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), abnormalTemperature(2), normalTemperature(3)  

a1gEthBusAdmAction 1.3.6.1.4.1.75.1.1.2.7.1.5
The administrative status of a module's Ethernet Bus interface (action). For an ASM320, if a1gEthBusMgmtStatus == lockedByJumper, then values of this attribute cannot be set.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unlock(2), lock(3)  

a1gEthBusMgmtStatus 1.3.6.1.4.1.75.1.1.2.7.1.6
The management status of a module's Ethernet bus interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), unlocked(2), locked(3), notResponding(4), autosegmented(5), hardwareFault(6), lockedByJumper(7)  

a1gNetMgmtBusOperStatus 1.3.6.1.4.1.75.1.1.2.7.1.7
The operational status of the network management interface from the supervisor to the module (the control bus).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), enabled(2), notResponding(3)  

a1gProductType 1.3.6.1.4.1.75.1.1.2.7.1.8
The product type of an A/1 card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), suprv-780(2), suprv-700(3), brsuprv-760(4), brsuprv-710(5), net-500(6), net-550(7), brnet-560(8), brnet-510(9), trc-400(10), ecm-300(11), tec-900(12), fec-800(13), ecm-310(14), async-100(15), mtm-7100(16), m3270(17), lebr-5300(18), ltebr-5500(19), lttbr-5550(20), t1ebr-6300(21), t1tbr-6500(22), lftbr-5560(23), lfebr-5360(24), lebr-5340(25), ecm-320-1(26), ecm-320-2(27), trc-410-1(28), trc-410-2(29), suprv-790(30), ausup-700s(31), tpsup-700s(32), suprv-790s16(33), fosup-700s(34), suprv-700s(35), net-500s(36), rr-8300(37), rr-8310(38), rr-8320(39), rr-8500(40), rr-8510(41), rr-8520(42), fBrR-5361(43), eTBrR-5530(44), eBrR-5330(45), suprv-790s4(46)  

a1gUpTime 1.3.6.1.4.1.75.1.1.2.7.1.9
The elapsed time since the module started operating.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

a1gResets 1.3.6.1.4.1.75.1.1.2.7.1.10
The number of times a module has been reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

a1gResetAction 1.3.6.1.4.1.75.1.1.2.7.1.11
When this internet-object is SET to one of the request values, the card resets, and after resetting retains the value that was SET. Initially its value is not-requested.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noResetRequested(1), enterDebugMode(2), podThenDebug(3), podThenNetdownload(4)  

configTable 1.3.6.1.4.1.75.1.1.2.8
config: Access/1 Group Configuration TABLE Row selection: the card's relative position in the enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConfigEntry

configEntry 1.3.6.1.4.1.75.1.1.2.8.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConfigEntry  

configSlotId 1.3.6.1.4.1.75.1.1.2.8.1.1
The card's relative position in the enclosure, starting at 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configFaultActionType 1.3.6.1.4.1.75.1.1.2.8.1.2
The action to be taken by the Supervisor following a fault on a card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER reset(2), stayInReset(3), noSupvAction(4)  

configRetries 1.3.6.1.4.1.75.1.1.2.8.1.3
The maximum number of times a reset is attempted when configFaultAction is set to reset (no further attempts are made once the reset is successful).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

configPowerUpMode 1.3.6.1.4.1.75.1.1.2.8.1.4
The actions taken by the module immediately after power up (pod is Power On Diagnostics).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), debug(2), podThenDebug(3), podThenNetdownload(4), pod-CopyUserMem-Run(5), pod-CopyDefaults-Run(6)  

a1imTable 1.3.6.1.4.1.75.1.1.2.9
a1im: Access/1 Intelligent Module TABLE Row selection: the value of the internet-object a1imSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    A1imEntry

a1imEntry 1.3.6.1.4.1.75.1.1.2.9.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  A1imEntry  

a1imSlotId 1.3.6.1.4.1.75.1.1.2.9.1.1
The relative slot position of a card, starting at 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

a1imMACAddr 1.3.6.1.4.1.75.1.1.2.9.1.2
The module's MAC address (for a bridge, its first network interface). May be (e.g., for the TRC-410) a unique id chosen from the set of MAC addresses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

a1imPodDiagnosticMsg 1.3.6.1.4.1.75.1.1.2.9.1.3
A text message describing a power-on-diagnostic state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

a1imModuleFault 1.3.6.1.4.1.75.1.1.2.9.1.4
Faults detected by the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), noFault(2), parityError(3), networkError(4), diagosticError(5), operationalError(6)  

a1imHaltReason 1.3.6.1.4.1.75.1.1.2.9.1.5
The last specific halt reason detected by the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notAvailable(1), unexpectedSoftInterrupt(2), halted(3), singleStepped(4), breakpoint(5), errorDivideByZero(6), badSingleStep(7), nonMaskableInterrupt(8), badBreakpoint(9), arithmeticOverflow(10), exceededArrayBounds(11), invalidOpcode(12), invalidEscapeOpcode(13), timer-0Interrupt(14), reservedInterrupt(15), dma-0Interrupt(16), dma-1Interrupt(17), int-0Interrupt(18), int-1Interrupt(19), int-2Interrupt(20), timer-1Interrupt(21), timer-2Interrupt(22), parityError(23), watchDogTimeout(24)  

a1imDebugRegisters 1.3.6.1.4.1.75.1.1.2.9.1.6
A set of 14 80186 registers used for debugging purposes. These are CS, IP, FLAG, AX, BX, CX, DX, SP, BP, SI, DI, DS, ES, and SS.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tplTable 1.3.6.1.4.1.75.1.1.2.10
tpl: Transport Layer TABLE Row selection: the value of the internet-object tplSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TplEntry

tplEntry 1.3.6.1.4.1.75.1.1.2.10.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TplEntry  

tplSlotId 1.3.6.1.4.1.75.1.1.2.10.1.1
The relative slot position of a card, starting at 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tplIPAddress 1.3.6.1.4.1.75.1.1.2.10.1.2
The card's IP address (only applies to TCP/IP)
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

tplNiuName 1.3.6.1.4.1.75.1.1.2.10.1.3
The card's Niu name (only applies to ISO)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

tplProtocolType 1.3.6.1.4.1.75.1.1.2.10.1.4
The type of transport protocol used by the module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), xns(2), tcpIp(3), iso(4), any(5)  

tplSuprvPollStatus 1.3.6.1.4.1.75.1.1.2.10.1.5
Indicates whether the module has responded to supervisor polling over Ethernet.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), responding(2), notResponding(3), pollingSuspended(4), cannotPoll(5)  

imenEthBusTable 1.3.6.1.4.1.75.1.1.2.11
imen: Intelligent Module Ethernet Datalink TABLE (Ethernet Bus interface) Row selection: the value of the internet-object imenSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ImenEthBusEntry

imenEthBusEntry 1.3.6.1.4.1.75.1.1.2.11.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ImenEthBusEntry  

imenSlotId 1.3.6.1.4.1.75.1.1.2.11.1.1
The relative position of the card in the enclosure, starting from 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

imenTransmitPkts 1.3.6.1.4.1.75.1.1.2.11.1.2
The total number of packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imenReceivePkts 1.3.6.1.4.1.75.1.1.2.11.1.3
The total number of packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imenCRCErrors 1.3.6.1.4.1.75.1.1.2.11.1.4
The number of packets received with CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

imenCollisions 1.3.6.1.4.1.75.1.1.2.11.1.5
The number of packets transmitted with collision detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brdgTable 1.3.6.1.4.1.75.1.1.2.12
brdg: Bridge TABLE Row selection: the value of the internet-object brdgSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus the relative interface, brdgIfId, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrdgEntry

brdgEntry 1.3.6.1.4.1.75.1.1.2.12.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrdgEntry  

brdgSlotId 1.3.6.1.4.1.75.1.1.2.12.1.1
The relative slot (from 1) containing this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brdgIfId 1.3.6.1.4.1.75.1.1.2.12.1.2
The relative interface (from 1) of this entry (see the appropriate hardware specification to determine which interface is 1, 2, etc.).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brdgIfType 1.3.6.1.4.1.75.1.1.2.12.1.3
The type of bridge interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ethernetBus(2), baseband802-3(3), fourMbps802-5(4), fddi(5), t1(6), broadband802-3(7), sixteenMbps802-5(8)  

brdgIfFault 1.3.6.1.4.1.75.1.1.2.12.1.4
Bridge faults (note these are interface specific).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), linkDown(2), linkUp(3), linkLoopbackTest(4)  

brdgIfMACAddr 1.3.6.1.4.1.75.1.1.2.12.1.5
The MAC address of the bridge's specific interface
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

ecTable 1.3.6.1.4.1.75.1.1.2.13
ec: Ethernet Concentrator TABLE Row selection: the value of the internet-object ecSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EcEntry

ecEntry 1.3.6.1.4.1.75.1.1.2.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EcEntry  

ecSlotId 1.3.6.1.4.1.75.1.1.2.13.1.1
The relative slot (from 1) containing this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ecCarrierCounter 1.3.6.1.4.1.75.1.1.2.13.1.2
The number of times carrier was sensed when sampled every 2 ms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ecFanStatus 1.3.6.1.4.1.75.1.1.2.13.1.3
The status of the Temp/Flex mount adaptor fan (on the ASM-800 (fiber EC) only).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), normalFan(2), abnormalFan(3)  

netTable 1.3.6.1.4.1.75.1.1.2.14
net: NET Card TABLE Row selection: the value of the internet-object netSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    NetEntry

netEntry 1.3.6.1.4.1.75.1.1.2.14.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  NetEntry  

netSlotId 1.3.6.1.4.1.75.1.1.2.14.1.1
The relative slot (from 1) containing this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

netBackboneType 1.3.6.1.4.1.75.1.1.2.14.1.2
The type of backbone to which the NET interface is attached.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER baseband(2), broadband(3)  

netFault 1.3.6.1.4.1.75.1.1.2.14.1.3
An interface fault at various points between the module and the attached backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), internalFault(2), auiBad(3), mdiBad(4), bufferedRepeaterBad(5), normal(6)  

netBackboneStatus 1.3.6.1.4.1.75.1.1.2.14.1.4
Backbone interface status: the status of the interface or interfaces to the backbone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), netOnly(2), netAndSupDirect(3), loopback(4), bridgeOnly(5), standby(6)  

brnTable 1.3.6.1.4.1.75.1.1.2.15
brn: Buffer Repeater NET Card TABLE Row selection: the value of the internet-object brnSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus the relative interface, brnIfId (1 or 2).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrnEntry

brnEntry 1.3.6.1.4.1.75.1.1.2.15.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrnEntry  

brnSlotId 1.3.6.1.4.1.75.1.1.2.15.1.1
The relative slot (from 1) containing this card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brnIfId 1.3.6.1.4.1.75.1.1.2.15.1.2
The relative interface (from 1) containing this card; interface 1 is the Ethernet Bus interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER if-1(1), if-ETHBUS(2)  

brnIfEthDLCStatus 1.3.6.1.4.1.75.1.1.2.15.1.3
The Ethernet Data Link Control status of the last transmission to the segment attached to the buffered repeater net card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), parityError(3), collisions-16(4), collision(5), underflow(6)  

brnCarrierCounter 1.3.6.1.4.1.75.1.1.2.15.1.4
The number of times carrier was sensed when sampled every 1 ms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnCarrierTimeInterval 1.3.6.1.4.1.75.1.1.2.15.1.5
The time interval over which brnCarrierCounter counts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

brnTransmitPkts 1.3.6.1.4.1.75.1.1.2.15.1.6
The total number of packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnReceivePkts 1.3.6.1.4.1.75.1.1.2.15.1.7
The total number of packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnCRCErrors 1.3.6.1.4.1.75.1.1.2.15.1.8
The number of packets received with CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnCollisions 1.3.6.1.4.1.75.1.1.2.15.1.9
The number of collisions detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnPktsAborted16Colls 1.3.6.1.4.1.75.1.1.2.15.1.10
The number of packets aborted because of 16 consecutive collisions detected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnShortPkts 1.3.6.1.4.1.75.1.1.2.15.1.11
The total number of short packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnAlignmentErrors 1.3.6.1.4.1.75.1.1.2.15.1.12
The total number of packets received with alignment errors: the number of frames received that are not an integral number of octets and do not pass the FCS check.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnOverflows 1.3.6.1.4.1.75.1.1.2.15.1.13
The number of packets received that had to be discarded due to errors in bit frequency resulting in overflow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

brnUnderflows 1.3.6.1.4.1.75.1.1.2.15.1.14
The number of packets received that had to be discarded due to errors in bit frequency resulting in underflow.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cTable 1.3.6.1.4.1.75.1.1.2.16
tr16c: Token Ring Concentrator Card TABLE Row selection: the value of the internet-object tr16cSlotId, which contains the relative position of a card within an enclosure, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Tr16cEntry

tr16cEntry 1.3.6.1.4.1.75.1.1.2.16.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Tr16cEntry  

tr16cSlotId 1.3.6.1.4.1.75.1.1.2.16.1.1
The relative slot number, starting at 1, of the concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16cTier 1.3.6.1.4.1.75.1.1.2.16.1.2
17,32 RelayID Indicates the management level of functionality (tier) of this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER tier-1(1), tier-2(2), tier-3(3)  

tr16cOperState 1.3.6.1.4.1.75.1.1.2.16.1.3
The operational state of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), normal(2), beaconDetectInProgress(3)  

tr16cRingNumber 1.3.6.1.4.1.75.1.1.2.16.1.4
The ring number assigned when configuring a bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16cManufacturerID 1.3.6.1.4.1.75.1.1.2.16.1.5
The Organization Unique Identifier as defined in IEEE 802.1A, Overview and Architecture. This is the first 24 bits of UB's MAC address identifying UB uniquely worldwide and is a constant equal to 00DD00 in hexadecimal.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tr16cManufacturerProductID 1.3.6.1.4.1.75.1.1.2.16.1.6
A string of ASCII characters representing the concentrator's product identifier (i.e., a name identifying an enumeration of a1gProductType). Some examples are 'trc-410-1' and 'trc-410-2'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

tr16cManufProductVers 1.3.6.1.4.1.75.1.1.2.16.1.7
A string that is unique for a specific manufacturerProductID that identifies a concentrators's hardware and firmware versions. The two octets are non-negative integers with values from 0 through 255. If a version does not apply then the version number is zero. One is the first applicable version number. The first octet is the hardware version and the second is the firmware version.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

tr16cActiveMonitorPortNumber 1.3.6.1.4.1.75.1.1.2.16.1.8
The relative port number of the active monitor for this ring. Its value is 0 if the active monitor is not attached to any port on this concentrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16cRingSpeed 1.3.6.1.4.1.75.1.1.2.16.1.9
17 RingSpeed The current concentrator operating speed of either 4 or 16 Mbps. Note that each concentrator in a ring must be configured with the same value of this attribute.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), fourMbps(2), sixteenMbps(3)  

tr16cLLCFrames 1.3.6.1.4.1.75.1.1.2.16.1.10
26 TotalLLCFramesThe total number of transmitted frames that are not MAC level management frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cMACFrames 1.3.6.1.4.1.75.1.1.2.16.1.11
26 TotalMACFramesThe total number of transmitted frames that are MAC level management frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cOctets 1.3.6.1.4.1.75.1.1.2.16.1.12
26 TotalOctetsThe total number of octets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cMulticastFrames 1.3.6.1.4.1.75.1.1.2.16.1.13
26 TotalMulticastFramesThe total number of frames with a destination address that is either a Functional Group Address or a Group Address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cBroadcastFrames 1.3.6.1.4.1.75.1.1.2.16.1.14
26 TotalBroadcastFramesThe total number of frames with a destination address that is a Broadcast Address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cFrameCheckSequences 1.3.6.1.4.1.75.1.1.2.16.1.15
26,27 TotalFrameCheckSequenceThe total number of packets with an FCS error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cAutoPartitionEnableTimer 1.3.6.1.4.1.75.1.1.2.16.1.16
25 AutoPartitionEnableTimer *a Indicates the period of time to wait until re-enabling a 'beacon detected' port. the default value is 0 seconds
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

tr16cAutoPartitionHoldTimer 1.3.6.1.4.1.75.1.1.2.16.1.17
25 AutoPartitionHoldTimer *a Indicates the amount of time to wait until starting the beacon detect process. The default value is 0 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  TimeTicks  

tr16cAutoPartitionRetries 1.3.6.1.4.1.75.1.1.2.16.1.18
25 AutoPartitionThreshold *a Indicates the number of times a port can be temporarily locked by the beacon detect process prior to being permanently locked. The default value is 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

tr16cLLCSamples 1.3.6.1.4.1.75.1.1.2.16.1.19
26,27 BandwidthUtilizationA count of the number of times that an LLC packet was present when sampling every millisecond.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cMACSamples 1.3.6.1.4.1.75.1.1.2.16.1.20
26,27 BandwidthUtilizationA count of the number of times that a MAC frame was present when sampling every millisecond.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cUpTimeMS 1.3.6.1.4.1.75.1.1.2.16.1.21
26,27 BandwidthUtilization The elapsed time in milliseconds since the concentrator started operating.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16cResetDurableUserAttrs 1.3.6.1.4.1.75.1.1.2.16.1.22
A request to copy the default values stored in durable memory to the User Durable attributes also in durable memory. The User attributes affected are tr16cRingSpeed, tr16p1AllowInsert, tr16p1ForceInsert, tr16cAutoPartitionEnableTimer, tr16cAutoPartitionHoldTimer, and tr16cAutoPartitionRetries.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER resetComplete(1), setToDefaults(2)  

tr16reTable 1.3.6.1.4.1.75.1.1.2.17
tr16re: Token Ring Concentrator Ring Error TABLE Row selection: the value of the internet-object tr16cSlotId, which contains the relative position of a card within an enclosure, starting at 1. Contains ring error monitor non-isolating errors.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Tr16reEntry

tr16reEntry 1.3.6.1.4.1.75.1.1.2.17.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Tr16reEntry  

tr16reSlotId 1.3.6.1.4.1.75.1.1.2.17.1.1
The relative slot in the hub enclosure, starting at 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16reLostFrames 1.3.6.1.4.1.75.1.1.2.17.1.2
Non-isolating lost frames.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16reRcvCongestionErrors 1.3.6.1.4.1.75.1.1.2.17.1.3
Non-isolating congestion on receive errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16reFrequencyErrors 1.3.6.1.4.1.75.1.1.2.17.1.4
Non-isolating frequency errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16reFrameCopyErrors 1.3.6.1.4.1.75.1.1.2.17.1.5
Non-isolating frame copy errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16reTokenErrors 1.3.6.1.4.1.75.1.1.2.17.1.6
Non-isolating token errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ecpTable 1.3.6.1.4.1.75.1.1.3.1
PORT Group ecp: Ethernet Port TABLE Row selection: the value of the internet-object ecpSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus a relative port identifier, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EcpEntry

ecpEntry 1.3.6.1.4.1.75.1.1.3.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EcpEntry  

ecpSlotId 1.3.6.1.4.1.75.1.1.3.1.1.1
The relative slot (from 1) containing the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ecpPortId 1.3.6.1.4.1.75.1.1.3.1.1.2
The relative port (from 1) on the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ecpMgmtStatus 1.3.6.1.4.1.75.1.1.3.1.1.3
The management status of an Ethernet port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), enabled(2), lockedByNMC(3), autosegmented(4), faultyLockedBySuprv(5), lowLight(6)  

ecpAdmAction 1.3.6.1.4.1.75.1.1.3.1.1.4
The administrative status of an Ethernet port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unlocked(2), locked(3)  

ecpCarrierCounter 1.3.6.1.4.1.75.1.1.3.1.1.5
The number of times carrier was sensed on the port when sampled every 2 ms.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ecfpTable 1.3.6.1.4.1.75.1.1.3.2
ecfp: Ethernet Concentrator Fiber Port TABLE Row selection: the value of the internet-object ecfpSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus the relative port identifier, ecfpPortId, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EcfpEntry

ecfpEntry 1.3.6.1.4.1.75.1.1.3.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  EcfpEntry  

ecfpSlotId 1.3.6.1.4.1.75.1.1.3.2.1.1
The relative slot (from 1) containing the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ecfpPortId 1.3.6.1.4.1.75.1.1.3.2.1.2
The relative port (from 1) on the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ecfpMACAddr 1.3.6.1.4.1.75.1.1.3.2.1.3
The latest source MAC address from packets received from the MAC side of the AUI
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

ecfpTxIdleTime 1.3.6.1.4.1.75.1.1.3.2.1.4
The elapsed time since the last packet was transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

ec10btpTable 1.3.6.1.4.1.75.1.1.3.3
ec10btp: Ethernet Concentrator 10BaseT Port TABLE Row selection: the value of the internet-object ec10btpSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus the relative port identifier, ec10btpPortId, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ec10btpEntry

ec10btpEntry 1.3.6.1.4.1.75.1.1.3.3.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ec10btpEntry  

ec10btpSlotId 1.3.6.1.4.1.75.1.1.3.3.1.1
The relative slot (from 1) containing the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ec10btpPortId 1.3.6.1.4.1.75.1.1.3.3.1.2
The relative port (from 1) on the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ec10btpLinkTestStatus 1.3.6.1.4.1.75.1.1.3.3.1.3
The result of the link integrity test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER testLocked(2), testFailed(3), testPassed(4)  

ec10btpLinkTestAction 1.3.6.1.4.1.75.1.1.3.3.1.4
A request to unlock the link integrity test (which is a continuous test).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unlockIntegrityTest(2), lockIntegrityTest(3)  

trcpTable 1.3.6.1.4.1.75.1.1.3.4
trcp: Token Ring Concentrator Port TABLE Row selection: the value of the internet-object trcpSlotId, which contains the relative position of a card within an enclosure, starting at 1, plus a relative port identifier starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrcpEntry

trcpEntry 1.3.6.1.4.1.75.1.1.3.4.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrcpEntry  

trcpSlotId 1.3.6.1.4.1.75.1.1.3.4.1.1
The relative slot (from 1) containing the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trcpPortId 1.3.6.1.4.1.75.1.1.3.4.1.2
The relative port (from 1) on the card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rs1(1), rs2(2), rs3(3), rs4(4), rs5(5), rs6(6), rs7(7), rs8(8), rs9(9), rs10(10), rs11(11), rs12(12), rs13(13), rs14(14), rs15(15), rs16(16), rs17(17), rs18(18), rs19(19), rs20(20), in(21), out(22)  

trcpAdmAction 1.3.6.1.4.1.75.1.1.3.4.1.3
The administrative status of a token ring port. It reflects only administrative status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), unlock(2), lock(3)  

trcpOperStatus 1.3.6.1.4.1.75.1.1.3.4.1.4
The operational status of a token ring port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER stationInserted(2), selfBypass(3), portError(4)  

tr16p1Table 1.3.6.1.4.1.75.1.1.3.5
tr16p1: Token Ring Concentrator Port Tier 1 TABLE Row selection: the value of the internet-object tr16p1SlotId, which contains the relative position of a card within an enclosure, starting at 1 plus the value of tr16p1PortId, which contains the relative position of a port within a card, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Tr16p1Entry

tr16p1Entry 1.3.6.1.4.1.75.1.1.3.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Tr16p1Entry  

tr16p1SlotId 1.3.6.1.4.1.75.1.1.3.5.1.1
The relative position (starting at 1) of the concentrator's slot within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16p1PortId 1.3.6.1.4.1.75.1.1.3.5.1.2
The relative port on the card starting at 1. Ports 1-12 are ring station ports, 13 is the expansion in port, and 14 is the expansion out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rs1(1), rs2(2), rs3(3), rs4(4), rs5(5), rs6(6), rs7(7), rs8(8), rs9(9), rs10(10), rs11(11), rs12(12), in(13), out(14)  

tr16p1InsertionState 1.3.6.1.4.1.75.1.1.3.5.1.3
The end result of tr16p1AllowInsert, tr16p1ForceInsert, and tr16p1PhantomState, i.e., inserted means tr16p1ForceInsert | tr16p1AllowInsert & tr16p1PhantomState, where tr16p1ForceInsert is true if requested, tr16p1AllowInsert is true if requested, and tr16p1PhantomState is true if phantomPresent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), inserted(2), bypassed(3)  

tr16p1AllowInsert 1.3.6.1.4.1.75.1.1.3.5.1.4
19 RingStationPortAction *aAn action that allows an RS port to insert onto its ring if both phantom voltages are present (tr16p1PhantomState is phantomPresent).20 ExpansionInPortAction *aWhen not allowed, this bypass forces a 'loop-back' to occur on the XI port, and does not allow concentrators to insert onto their rings.21 ExpansionOutPortAction *aWhen not allowed this bypass forces a 'loop-back' to occur on the XO port so that an attached ASM400 or ASM410 is not inserted when phantom voltage is detected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), insertionNotAllowed(2), insertionAllowed(3)  

tr16p1ForceInsert 1.3.6.1.4.1.75.1.1.3.5.1.5
19 RingStationPortInsert *aWhen forcedInsertion, forces an RS port to insert onto its ring regardless of whether phantom voltage or other conditions are detected. This is used to support passive devices, such as the IBM MSAU, in order to support the Satellite expansion capability.19 ExpansionInPortInsert *aWhen set, inserts the XI port onto the ring regardless of whether phantom voltage is present.21 ExpansionOutPortInsert *aForces XI port to insert on the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), noForcedInsertion(2), forcedInsertion(3)  

tr16p1PhantomState 1.3.6.1.4.1.75.1.1.3.5.1.6
19 ExpansionInPhantomDetect Indicates the XI port detects phantom voltage being provided.20 ExpansionOutPhantomLoadDetect The status of the phantom voltage provided by the XO port (XO->XI or XO->RS (satellite)).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), phantomVoltagePresent(2), phantomVoltageAbsent(3), wiringFault(4)  

tr16p2Table 1.3.6.1.4.1.75.1.1.3.6
tr16p2: Token Ring Concentrator Port Tiers 2,3 TABLE Row selection: the value of the internet-object tr16p2SlotId, which contains the relative position of a card within an enclosure, starting at 1 plus the value of tr16p2PortId, which contains the relative position of a port within a card, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Tr16p2Entry

tr16p2Entry 1.3.6.1.4.1.75.1.1.3.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Tr16p2Entry  

tr16p2SlotId 1.3.6.1.4.1.75.1.1.3.6.1.1
The relative position (starting at 1) of the concentrator's slot within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16p2PortId 1.3.6.1.4.1.75.1.1.3.6.1.2
The relative port on the card starting at 1. Ports 1-12 are ring station ports, 13 is the expansion in port, and 14 is the expansion out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rs1(1), rs2(2), rs3(3), rs4(4), rs5(5), rs6(6), rs7(7), rs8(8), rs9(9), rs10(10), rs11(11), rs12(12), in(13), out(14)  

tr16p2OperState 1.3.6.1.4.1.75.1.1.3.6.1.3
25 RingStationAutoPartitionState25 RingExpansionInPartitionState25 ExpansionOutAutoPartitionState Indicates whether a hard failure has occurred on a port, been detected through the beaconing procedure, and the offending port subsequently bypassed in the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notApplicable(1), portOperational(2), autoPartitioned(3)  

tr16p2BeaconDetects 1.3.6.1.4.1.75.1.1.3.6.1.4
25 RingStationAutoPartitionCount25 ExpansionInAutoPartitionCount25 ExpansionOutAutoPartitionCount Indicates the number of beacon detects that have resulted in this port being partitioned (removed from its ring).
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2LastSourceAddress 1.3.6.1.4.1.75.1.1.3.6.1.5
23,27 RingStationLastSourceAddress23,27 ExpansionInLastSourceAddress23,27 ExpansionOutLastSourceAddress Address of previously attached node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

tr16p2LLCFramesTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.6
27 RingStationLLCFramesTransmitted 27 ExpansionInLLCFramesTransmitted 27 ExpansionOutLLCFramesTransmitted Total number of non-MAC Management packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2LLCFramesReceived 1.3.6.1.4.1.75.1.1.3.6.1.7
27 RingStationLLCFramesReceived 27 ExpansionInLLCFramesReceived 27 ExpansionOutLLCFramesReceived Total number of non-MAC Management packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2MACFramesTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.8
27 RingStationMACFramesTransmitted27 ExpansionInMACFramesTransmitted27 ExpansionOutMACFramesTransmitted Total number of MAC Management packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2MACFramesReceived 1.3.6.1.4.1.75.1.1.3.6.1.9
27 RingStationMACFramesReceived27 ExpansionInMACFramesReceived27 ExpansionOutMACFramesReceived Total number of MAC Management packets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2OctetsTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.10
27 RingStationOctetsTransmitted27 ExpansionInOctetsTransmitted27 ExpansionOutOctetsTransmitted Total number of LLC Information octets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2OctetsReceived 1.3.6.1.4.1.75.1.1.3.6.1.11
27 RingStationOctetsReceived27 ExpansionInOctetsReceived27 ExpansionOutOctetsReceived Total number of LLC Information Field octets received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2MulticastsTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.12
28 RingStationMulticastTransmitted 28 ExpansionInMulticastTransmitted 28 ExpansionOutMulticastTransmitted Total number of Multicast packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2BroadcastsTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.13
28 RingStationBroadcastTransmitted28 ExpansionOutBroadcastTransmitted28 ExpansionInBroadcastTransmitted Total number of Broadcast packets transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2FCSErrorsTransmitted 1.3.6.1.4.1.75.1.1.3.6.1.14
28 RingStationFCSErrorsTransmitted28 ExpansionInFCSErrorsTransmitted28 ExpansionOutFCSErrorsTransmitted Total number of packets transmitted with an FCS error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2FCSErrorsReceived 1.3.6.1.4.1.75.1.1.3.6.1.15
28 RingStationFCSErrorsReceived28 ExpansionInFCSErrorsReceived28 ExpansionOutFCSErrorsReceived Total number of packets received with an FCS error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p2LastSourceAddressUptime 1.3.6.1.4.1.75.1.1.3.6.1.16
Time since the value of tr16p2LastSourceAddress last changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

tr16p3Table 1.3.6.1.4.1.75.1.1.3.7
tr16p3: Token Ring Concentrator Port Tiers 2,3 TABLE Row selection: the value of the internet-object tr16p3SlotId, which contains the relative position of a card within an enclosure, starting at 1 plus the value of tr16p3PortId, which contains the relative position of a port within a card, starting at 1.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Tr16p3Entry

tr16p3Entry 1.3.6.1.4.1.75.1.1.3.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Tr16p3Entry  

tr16p3SlotId 1.3.6.1.4.1.75.1.1.3.7.1.1
The relative position (starting at 1) of the concentrator's slot within the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tr16p3PortId 1.3.6.1.4.1.75.1.1.3.7.1.2
The relative port on the card starting at 1. Ports 1-12 are ring station ports, 13 is the expansion in port, and 14 is the expansion out port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER rs1(1), rs2(2), rs3(3), rs4(4), rs5(5), rs6(6), rs7(7), rs8(8), rs9(9), rs10(10), rs11(11), rs12(12), in(13), out(14)  

tr16p3LineErrors 1.3.6.1.4.1.75.1.1.3.7.1.3
Isolating line errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p3InternalErrors 1.3.6.1.4.1.75.1.1.3.7.1.4
Isolating internal errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p3Burst5Errors 1.3.6.1.4.1.75.1.1.3.7.1.5
Isolating burst 5 errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p3AcErrors 1.3.6.1.4.1.75.1.1.3.7.1.6
Isolating AC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

tr16p3AbortDelimiters 1.3.6.1.4.1.75.1.1.3.7.1.7
Isolating abort delimiters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trapInstanceId 1.3.6.1.4.1.75.3.1
TRAP Group: The attributes that may appear in the variable-bindings list of the Trap-PDU. An instance identifier that uniquely identifies an occurrence of a trap. Note that if multiple Trap-PDUs are sent to reflect the occurrence of the same trap, each contains the same value of the trapInstanceId.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapSlotId 1.3.6.1.4.1.75.3.2
trapSource (consists of the following):The attributes required to define the source of the trap. For example, when a port is unlocked, the slot identifier and port identifier define the source of the trap. The product type is also included in case the enterprise field in the trap-PDU does not completely distinguish the characteristics of the source. The relative slot (from 1) containing the card that the trap is about.
Status: optional Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapProductType 1.3.6.1.4.1.75.3.3
The product type of the Access/One card that the trap is about.See a1gProductType for specific values.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapPortID 1.3.6.1.4.1.75.3.4
The relative port (from 1) that the trap is about.
Status: optional Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapPortCount 1.3.6.1.4.1.75.3.15
The number of ports on a concentrator.
Status: optional Access: not-accessible
OBJECT-TYPE    
  INTEGER  

trapPortMask 1.3.6.1.4.1.75.3.16
A mask indicating the status of ports on the concentrator.
Status: optional Access: not-accessible
OBJECT-TYPE    
  OCTET STRING  

trpsbTable 1.3.6.1.4.1.75.4.1.2
TRAP SUBSCRIPTION Group Trap Subscription TABLE Row selection: the value of the internet-object trpsbIpAddress identifies a row corresponding to a valid member of an agent's community. This table contains 5 entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrpsbEntry

trpsbEntry 1.3.6.1.4.1.75.4.1.2.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrpsbEntry  

trpsbIpAddress 1.3.6.1.4.1.75.4.1.2.1.1
The IP address of a manager subscribing to traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

trpsbCommunity 1.3.6.1.4.1.75.4.1.2.1.2
The community string identifying a manager subscribing to traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

trpsbActions 1.3.6.1.4.1.75.4.1.2.1.3
Actions on a manager's trap subscription.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER notApplicable(1), subscribeToTraps(2), subscriptionToTrapsCancelled(3)  

moduleInserted 1
A card was inserted in the Access/One chassis.
TRAP-TYPE    

moduleRemoved 2
A card was removed from the Access/One chassis.
TRAP-TYPE    

moduleFaulty 3
A card has become faulty: its state changed to a1gOperStatus (moduleFault(6)).
TRAP-TYPE    

moduleDown 4
A card has not responded to a supervisor poll: its state changed to a1gEthBusMgmtStatus(notResponding(4)).
TRAP-TYPE    

moduleReset 5
A card has been reset: its state changed to a1gOperStatus (reset(13)).
TRAP-TYPE    

moduleDebug 6
A card has put into debug mode: its state changed to a1gOperStatus (debugMode(4)).
TRAP-TYPE    

moduleHighTemperature 7
The card's temperature has become too high: its state changed to a1gTempStatus(abnormal(2)).
TRAP-TYPE    

ethBusUnlocked 8
The interface to the Ethernet bus has been unlocked: its state changed to a1gEthBusAdmAction(unlock(2)).
TRAP-TYPE    

ethBusLocked 9
The interface to the Ethernet bus has been locked: its state changed to a1gEthBusAdmAction(lock(3)).
TRAP-TYPE    

moduleNetIfEnabled 16
The status of the interface to the backbone has changed so that all modules (with the possible exception of the supervisor - when it is in direct mode) access the backbone through the card's net interface: a state change to netBackboneStatus(active(2)) has occurred.
TRAP-TYPE    

moduleNetIfDisabled 17
The status of the interface to the backbone has changed so that there is no communication backbone through the card's net interface: a state change to netBackboneStatus(standby(6)) has occurred
TRAP-TYPE    

moduleNetIfLoopBack 18
The status of the interface to the backbone has changed so that this card's net interface loops back traffic directed to the backbone, while the other (possible) net interface's status becomes standby: a state change to netBackboneStatus(loopback(4)) has occurred.
TRAP-TYPE    

moduleNetIfInternalError 19
An internal error at the net interface has been detected: its state changed to netFault(internal(2)).
TRAP-TYPE    

moduleNetIfExternalError 20
An external error at the net interface has been detected: its state changed to either netFault(auiBad(3)) or netFault(mdiBad(4)).
TRAP-TYPE    

moduleParityError 21
An intelligent module has detected a parity error: its status has changed to a1imModuleFault (parityErr(3)).
TRAP-TYPE    

moduleFanBad 22
The fan on the module is defective: its status has changed to ecFanStatus(abnormal(3)).
TRAP-TYPE    

beaconDetected 23
The ring containing this card has begun the beacon detect process: its status has changed to tr16cOperState(beaconDetectInProgress(4)).
TRAP-TYPE    

moduleTemperatureNormal 24
The card's temperature has returned to normal: its state changed from a1gTempStatus(abnormal(2)) to a1gTempStatus(normal(3)).
TRAP-TYPE    

portUnlocked 32
One or more of the concentrator's ports have been unlocked.
TRAP-TYPE    

portLocked 33
One or more of the concentrator's ports have been locked.
TRAP-TYPE    

portAutoSegmented 34
One or more of the concentrator's ports have been auto-segmented by the hardware because of a fault.
TRAP-TYPE    

portFault 35
One or more of the concentrator's ports have been segmented by the supervisor because of a fault.
TRAP-TYPE    

portForced 36
One or more of the concentrator's ports have been forced to allow passive devices to enter the ring.
TRAP-TYPE    

portNotForced 37
One or more of the concentrator's ports are no longer being forced to allow passive devices to enter the ring.
TRAP-TYPE    

portLobeFault 38
One or more of the concentrator's ports are experiencing a lobe fault. The concentrator experiences voltage(either positive or negative) in only one of the phantom pair wires.
TRAP-TYPE    

portLobeFaultCleared 39
One or more of the concentrator's ports are no longer experiencing a lobe fault.
TRAP-TYPE    

portLinkTestUnlocked 40
The link test on one or more of the concentrator's ports has been unlocked.
TRAP-TYPE    

portLinkTestLocked 41
The link test on one or more of the concentrator's ports has been locked.
TRAP-TYPE    

badPowerSupply 48
At least one power module has lost its AC power. : its state changed to hubPowerSupplyStatus(acPowerAbnormal(3)).
TRAP-TYPE    

powerSupplyHiTemp 49
The temperature of the power supply has become too high: its state changed to hubPowerSupplyStatus(highTemp(4)).
TRAP-TYPE    

networkIfError 50
One or more of the interfaces to the network backbone are experiencing faults: its state changed to ensupDynamicNetStatus(netOrSupLoopback(6)).
TRAP-TYPE    

networkIfOK 51
The interface to the backbone network has changed (recovered) by using a redundant connection. The state of the interface to the backbone network changed to one of ensupDynamicNetStatus(netAndSupDirect(2) | supOnly(3) | netOnly(4) | bridgeOnly(5)).
TRAP-TYPE    

tempBad 52
The temperature in the enclosure has been reported by an enclosure temperature sensor to be out of range(possible enclosure fan failure) or the temperature of at least one card in the enclosure is out of range: the hub's state changed to hubTempStatus(abnormal(2)).
TRAP-TYPE    

tempOK 53
The temperature of all cards in the enclosure is now in the proper range or the enclosure temperature has returned to the proper range: the hub's state changed to: hubTempStatus(normal(3))
TRAP-TYPE    

fTPSBad 54
One or both (for a fault tolerant power supply) dc power supplies have failed. The power supply's state has changed to: hubPowerSupplyStatus(onePsModuleFailed(5)).
TRAP-TYPE    

netUtilThreshold 55
The network utilization has been exceeded: ensupNetUtilization exceeded ensupNetUtilThreshold.
TRAP-TYPE    

enclosureFanBad 56
The enclosure has an airflow problem (probably a defective fan): the state of hubAFS has changed to abnormal(3).
TRAP-TYPE    

servicePortLogin 64
The interpreter on the netcard has detected a login command on the service port.
TRAP-TYPE    

servicePortLogout 65
The interpreter on the netcard has detected a logout command on the service port.
TRAP-TYPE