TY3250I-MIB

File: TY3250I-MIB.mib (77106 bytes)

Imported modules

SNMPv2-TC RFC1155-SMI RFC-1215
RFC-1212

Imported symbols

DisplayString Counter TimeTicks
enterprises IpAddress Gauge
TRAP-TYPE OBJECT-TYPE

Defined Types

Ty3250CfgCurrentConnections  
SEQUENCE    
  ty3250T1Index INTEGER
  ty3250Ds0 INTEGER
  ty3250DtePort INTEGER
  ty3250Type INTEGER

Ty3250CfgEditConnEntry  
SEQUENCE    
  ty3250ConnT1Index INTEGER
  ty3250ConnDS0 INTEGER
  ty3250ConnDTE INTEGER
  ty3250ConnType INTEGER

Ty3250CfgCommIntf  
SEQUENCE    
  ty3250CfgCommIndex INTEGER
  ty3250CfgCommBaud INTEGER
  ty3250CfgCommDataBits INTEGER
  ty3250CfgCommStopBits INTEGER
  ty3250CfgCommParity INTEGER
  ty3250CfgCommFlowCtrl INTEGER

Ty3250CfgCommMode  
SEQUENCE    
  ty3250CfgCommModeIndex INTEGER
  ty3250CfgCommMode INTEGER
  ty3250CfgCommMyIP IpAddress
  ty3250CfgCommPeerIP IpAddress
  ty3250CfgCommMask IpAddress
  ty3250CfgCommMaxMTU INTEGER

Ty3250SnmpEntry  
SEQUENCE    
  ty3250SnmpIndex INTEGER 1..6
  ty3250SnmpManagerIP IpAddress

Ty3250PortStatus  
SEQUENCE    
  ty3250IntfIndex INTEGER
  ty3250IntfType INTEGER
  ty3250IntfMode INTEGER
  ty3250IntfStatus INTEGER
  ty3250IntfAlarms INTEGER

Ty3250T1CurrentEntry  
SEQUENCE    
  ty3250T1CurrentIndex INTEGER
  ty3250T1CurrentCrc6Events Gauge
  ty3250T1CurrentOofEvents Gauge
  ty3250T1CurrentESs Gauge
  ty3250T1CurrentSESs Gauge
  ty3250T1CurrentSEFSs Gauge
  ty3250T1CurrentUASs Gauge
  ty3250T1CurrentCSSs Gauge
  ty3250T1CurrentBESs Gauge
  ty3250T1CurrentLCVs Gauge

Ty3250T1IntervalEntry  
SEQUENCE    
  ty3250T1IntervalIndex INTEGER
  ty3250T1IntervalNumber INTEGER
  ty3250T1IntervalESs Gauge
  ty3250T1IntervalSESs Gauge
  ty3250T1IntervalSEFSs Gauge
  ty3250T1IntervalUASs Gauge
  ty3250T1IntervalCSSs Gauge
  ty3250T1IntervalBESs Gauge
  ty3250T1IntervalLCVs Gauge

Ty3250T1TotalEntry  
SEQUENCE    
  ty3250T1TotalIndex INTEGER
  ty3250T1TotalESs Gauge
  ty3250T1TotalSESs Gauge
  ty3250T1TotalSEFSs Gauge
  ty3250T1TotalUASs Gauge
  ty3250T1TotalCSSs Gauge
  ty3250T1TotalBESs Gauge
  ty3250T1TotalLCVs Gauge

Ty3250T1PerfCmdType  
SEQUENCE    
  ty3250T1CommandIndex INTEGER
  ty3250T1PerfFreezeState INTEGER
  ty3250T1PerfClearEvents INTEGER
  ty3250T1PerfClearAll INTEGER

Defined Values


ty3250 1.3.6.1.4.1.466.4
OBJECT IDENTIFIER    

ty3250SysTable 1.3.6.1.4.1.466.4.1
OBJECT IDENTIFIER    

ty3250SysType 1.3.6.1.4.1.466.4.1.1
A textual description of the system model identifier. for example: TYLINK3250
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty3250SysSoftRev 1.3.6.1.4.1.466.4.1.2
Displays the Software Revision installed in this node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty3250SysHardRev 1.3.6.1.4.1.466.4.1.3
Displays the Hardware Revision of the node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

ty3250SysNumT1Installed 1.3.6.1.4.1.466.4.1.4
The number of network (T1) ports that are installed. There is 1 on the 3250.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

ty3250SysNumDteInstalled 1.3.6.1.4.1.466.4.1.5
The number of channels (DTE) that are installed. There is 1 on the 3250.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1  

ty3250SysNumCommInstalled 1.3.6.1.4.1.466.4.1.6
The number of Maintenance ports that are installed. The front panel MAINT port is for the user interface, the rear panel COMM port is for Lan(Network) Access.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2  

ty3250SysName 1.3.6.1.4.1.466.4.1.7
The user supplied name of the node. This object does not affect operation, but may be useful for network management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

ty3250SysResetNode 1.3.6.1.4.1.466.4.1.8
Command to reset the node. NODE WILL BE OFF-LINE AND USER DATA WILL BE INTERRUPTED FOR APPROXIMATELY 15 SECONDS.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset-node(321)  

ty3250CfgT1Table 1.3.6.1.4.1.466.4.3
OBJECT IDENTIFIER    

ty3250CfgT1Framing 1.3.6.1.4.1.466.4.3.1
Type of Framing on this T1 Line. Check with your service provider to determine value. D4 is also known as 'SuperFrame', ESF is 'Extended SuperFrame'. ESF provides enhanced performance monitoring capabilities. ANSI and 54016 refer to the ESF Facility Data Link (FDL).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER d4(1), esf-54016(2), esf-ansi(3)  

ty3250CfgT1LineEncoding 1.3.6.1.4.1.466.4.3.2
T1 interface bipolar encoding scheme. Check with your service provider to determine value. B8ZS, which inherently provides ample 'ones-density', is recommended. AMI users must pay special attention to the 'ones-density' requirements of the servic provider.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ami(1), b8zs(2)  

ty3250CfgT1Density 1.3.6.1.4.1.466.4.3.3
CSU 'ones density' monitor. Defines the maximum number of consecutive zeros that can be transmitted to the network. If density monitoring is enabled, the composite signal is guaranteed to meet the selected density threshhold at the expense of user data. No-density (4) should be used if B8ZS Line Encoding is chosen or if Channel Density is bit-7-stuff. This option is not applicable if DSX-1 mode is selected.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-density(1), twelve-half-percent(2), one-in-16(3), one-in-64(4)  

ty3250CfgT1Interface 1.3.6.1.4.1.466.4.3.4
Enables CSU-specific functions if CSU (1) is selected. CSU functions include Line Build-out, density monitoring, and certain diagnostic features. Selecting DSX-1 (2) will disable these CSU functions for line driver or external CSU applications.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dsx-1(1), csu(2)  

ty3250CfgT1LboSetting 1.3.6.1.4.1.466.4.3.5
CSU Line Build Out. Consult service provider for proper setting; either 0dB (1), -7.5dB (2), or -15dB (3). Not applicable if T1Interface = dsx1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER zero-db(2), n7-5-db(3), n15-db(1)  

ty3250CfgT1Timing 1.3.6.1.4.1.466.4.3.6
T1 network interface timing source. There must be only one source on a T1 line. Node should typically be network (2) timed on a point-to-network application. Line Driver and point-to-point applications typically need one node as internal (1), one as network (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), loop(2)  

ty3250CfgT1CicuitID 1.3.6.1.4.1.466.4.3.7
This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

ty3250CfgDteTable 1.3.6.1.4.1.466.4.4
OBJECT IDENTIFIER    

ty3250CfgDteLineRate 1.3.6.1.4.1.466.4.4.1
Serial Data Rate in bits-per-second, must be multiple of 8000bps. For example enter 768000 for 768Kb/s. Valid rates depend upon channel density selection: nX56K for bit-7-stuffing, and nX64K for clear-channel (n is an integer 1-24 inclusive).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..1536000  

ty3250CfgDteChannelDensity 1.3.6.1.4.1.466.4.4.2
Packing of serial data into T1 DS0's. Bit-7-stuff (56) allows DTE rates of nX56Kb/s and provides sufficient ones-density on any circuit. Clear-channel (64) allows rates on nX64Kb/s and may require an additional means of density enforcement (eg, B8ZS).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bit-7-stuff(56), clear-channel(64)  

ty3250CfgDteTiming 1.3.6.1.4.1.466.4.4.3
Serial DTE Transmit Timing mode. Loop-1 (1) uses the clock returned from the DTE (TT/TCE) to sample tx data, Loop-2 (2) uses the clock (ST/TC) generated by the node to sample tx data.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER loop-1(1), loop-2(2)  

ty3250CfgDteClockMode 1.3.6.1.4.1.466.4.4.4
Clock-normal samples data with the rising edge of the selected tx clock, clock-invert samples data with the falling edge of the selected tx clock. The tx clock is selected using CfgDteTiming. This clock invertion is most useful when loop-2 timing is used. Only in rare circumstances will clock-invert (2) be used with loop-1 timing.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clock-normal(1), clock-invert(2)  

ty3250CfgDteDataMode 1.3.6.1.4.1.466.4.4.5
Inverts data. Can make some applications, particularly HDLC-based protocols, meet density requirements even across clear channel DS0s in AMI mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER data-normal(1), data-invert(2)  

ty3250CfgDteIntfType 1.3.6.1.4.1.466.4.4.6
Sets the electrical interface for the DTE port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER intf-v35(3), intf-rs449(4)  

ty3250CfgConnectTable 1.3.6.1.4.1.466.4.5
OBJECT IDENTIFIER    

ty3250CfgConnAutoAssign 1.3.6.1.4.1.466.4.5.1
OBJECT IDENTIFIER    

ty3250ConnAutoT1Index 1.3.6.1.4.1.466.4.5.1.1
Index to T1 network port of interest. 3250 supports one T1 network port (1)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..4  

ty3250ConnStartDS0 1.3.6.1.4.1.466.4.5.1.2
Port1-t1 includes 24 DS0's. This value is the starting DS0 used by the node to allocate DS0s to meet port2-dte's requirements. Sequential, contiguous DS0s are assigned. The number of DS0s required is based upon the DTE Data Rate and DTE Channel Mapping. The node's response to an entry may be gathered by querying ty3250ConnAutoStatus. To assign DS0s in a non-contiguous format, use the CfgEditConnTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ds0-01(1), ds0-02(2), ds0-03(3), ds0-04(4), ds0-05(5), ds0-06(6), ds0-07(7), ds0-08(8), ds0-09(9), ds0-10(10), ds0-11(11), ds0-12(12), ds0-13(13), ds0-14(14), ds0-15(15), ds0-16(16), ds0-17(17), ds0-18(18), ds0-19(19), ds0-20(20), ds0-21(21), ds0-22(22), ds0-23(23), ds0-24(24), no-current-connections(40), non-continuous-ds0s(41)  

ty3250ConnAutoPort 1.3.6.1.4.1.466.4.5.1.3
Selects the port for which DS0s are automatically allocated to on the T1 network port. Node software may not allow connection of port1-t1 to port1-t1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER port1-t1(1), port2-dte(2), not-connected(33)  

ty3250ConnAutoType 1.3.6.1.4.1.466.4.5.1.4
Defines the type of traffic being transported. The 3250 only supports data (1). The selected type will be assigned to all DS0s.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER data(1), voice(2)  

ty3250ConnDteRate 1.3.6.1.4.1.466.4.5.1.5
Data rate of the 3250's DTE port. Can be changed from the CfgDteTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..1536000  

ty3250ConnDteDensity 1.3.6.1.4.1.466.4.5.1.6
Channel/DS0 format for the 3250's DTE port. Can be changed from the CfgDteTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bit-7-stuff(56), clear-channel(64)  

ty3250ConnDs0Required 1.3.6.1.4.1.466.4.5.1.7
The number of DS0s required by the node's DTE port. This is based upon the DTE data rate and channel density selections.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..24  

ty3250ConnAutoStatus 1.3.6.1.4.1.466.4.5.1.8
Queries the node's connection status. Cause codes will be returned when a connection set is rejected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connections-valid(1), incorrect-bandwidth(2), bandwidth-conflict(3), no-current-connections(4)  

ty3250CfgCurrentConnTable 1.3.6.1.4.1.466.4.5.2
Retrieves node's active connections assignments for display only. To edit connections, use CfgConnAutoAssign or CfgEditConnTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250CfgCurrentConnections

ty3250CfgCurrentConnections 1.3.6.1.4.1.466.4.5.2.1
An entry in the Current Connections Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250CfgCurrentConnections  

ty3250T1Index 1.3.6.1.4.1.466.4.5.2.1.1
Index to T1 network port of interest. 3250 only supports one T1 network port (1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250Ds0 1.3.6.1.4.1.466.4.5.2.1.2
DS0 number 1 through 24 corresponding to the T1 network port index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

ty3250DtePort 1.3.6.1.4.1.466.4.5.2.1.3
DS0 assignment for indexed T1 network port. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent. Node software may not permit port1-t1 connections to itself.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER port1-t1(1), port2-dte(2), not-connected(33)  

ty3250Type 1.3.6.1.4.1.466.4.5.2.1.4
Defines the type of traffic being transported. The 3250 only supports data (1).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER data(1), voice(2)  

ty3250CfgEditConnMenu 1.3.6.1.4.1.466.4.5.3
OBJECT IDENTIFIER    

ty3250CfgEditConnCopyCurrtoEdit 1.3.6.1.4.1.466.4.5.3.1
Fill the edit buffer with the node's current active connections.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER copy-current(1)  

ty3250CfgEditConnTable 1.3.6.1.4.1.466.4.5.3.2
Edits current DS0 assignment. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250CfgEditConnEntry

ty3250CfgEditConnEntry 1.3.6.1.4.1.466.4.5.3.2.1
An entry in the Edit Connections table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250CfgEditConnEntry  

ty3250ConnT1Index 1.3.6.1.4.1.466.4.5.3.2.1.1
Index to T1 network port of interest. 3250 only supports one T1 network port (1)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250ConnDS0 1.3.6.1.4.1.466.4.5.3.2.1.2
DS0 number 1 through 24 corresponding to the T1 network port index
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..24  

ty3250ConnDTE 1.3.6.1.4.1.466.4.5.3.2.1.3
DS0 assignment for indexed T1 network port. After making any adjustments to the connections, the ty3250CfgConnUpdateCmd must be sent. Node software may not permit connections between port1-t1 and itself.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER port1-t1(1), port2-dte(2), not-connected(33)  

ty3250ConnType 1.3.6.1.4.1.466.4.5.3.2.1.4
defines the type of traffic being transported. The 3250 only supports data (1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER data(1), voice(2)  

ty3250CfgConnUpdate 1.3.6.1.4.1.466.4.5.3.3
OBJECT IDENTIFIER    

ty3250CfgConnUpdateCmd 1.3.6.1.4.1.466.4.5.3.3.1
Updates the connections with the edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER update(1)  

ty3250CfgConnStatus 1.3.6.1.4.1.466.4.5.3.3.2
Displays node status from the last connection update.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER connections-valid(1), incorrect-bandwidth(2), bandwidth-conflict(3), no-current-connections(4)  

ty3250CfgEditConnClearEditBuff 1.3.6.1.4.1.466.4.5.3.4
Removes all changes from edit buffer. The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clear-edit(1)  

ty3250CfgCommTable 1.3.6.1.4.1.466.4.6
OBJECT IDENTIFIER    

ty3250CfgCommFormat 1.3.6.1.4.1.466.4.6.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250CfgCommIntf

ty3250CfgCommIntf 1.3.6.1.4.1.466.4.6.1.1
Configuration of electrical interface and character format of the communications ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250CfgCommIntf  

ty3250CfgCommIndex 1.3.6.1.4.1.466.4.6.1.1.1
The comm (1) is at the rear and the maint (2) is at the front of the box.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER comm(1), maint(2)  

ty3250CfgCommBaud 1.3.6.1.4.1.466.4.6.1.1.2
Baud rate for this Communication port. Values are baud-1200 (1), baud-2400 (2), baud-4800 (3), baud-9600 (4), baud-19200 (5), baud-38400 (6).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER baud-1200(1), baud-2400(2), baud-4800(3), baud-9600(4), baud-19200(5), baud-38400(6)  

ty3250CfgCommDataBits 1.3.6.1.4.1.466.4.6.1.1.3
Databits for this Communication port. Values are databits-7 (1) and databits-8 (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER databits-7(1), databits-8(2)  

ty3250CfgCommStopBits 1.3.6.1.4.1.466.4.6.1.1.4
Number of Stopbits for this Communication port. Values are stopbits-1 (1), stopbits-1-5 (2), and stopbits-2 (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER stopbits-1(1), stopbits-1-5(2), stopbits-2(3)  

ty3250CfgCommParity 1.3.6.1.4.1.466.4.6.1.1.5
Parity for this Communication port. Values are no-parity (1), odd-parity (2), even-parity (3).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-parity(1), odd-parity(2), even-parity(3)  

ty3250CfgCommFlowCtrl 1.3.6.1.4.1.466.4.6.1.1.6
Flow Control for this Communication port. Values are off-flow-control (1) and on-flow-control (2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no-flow-control(1), software-flow-control(2), hardware-flow-control(3)  

ty3250CfgCommModeTable 1.3.6.1.4.1.466.4.6.2
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250CfgCommMode

ty3250CfgCommModeEntry 1.3.6.1.4.1.466.4.6.2.1
Ascii communication port configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250CfgCommMode  

ty3250CfgCommModeIndex 1.3.6.1.4.1.466.4.6.2.1.1
Communication port configured as user interface. The comm (1) is at the rear and the maint (2) is at the front of the box. The 3250 may require that the maint (2) port be used for user interface only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER comm(1), maint(2)  

ty3250CfgCommMode 1.3.6.1.4.1.466.4.6.2.1.2
Defines mode of operation of the selected communication port. The 3250 may require that the user-interface be assigned to the Maint port and a Network access type be assigned to the COMM port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER user-interface-vt100(1), slip(2), ethernet(3), token-ring(4)  

ty3250CfgCommMyIP 1.3.6.1.4.1.466.4.6.2.1.3
The IP address for this node's network access port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty3250CfgCommPeerIP 1.3.6.1.4.1.466.4.6.2.1.4
The IP address for other end of network access connection.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty3250CfgCommMask 1.3.6.1.4.1.466.4.6.2.1.5
The IP Network Mask (eg 255.255.255.0) for the network access link.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty3250CfgCommMaxMTU 1.3.6.1.4.1.466.4.6.2.1.6
The Maximum Transmission Unit is the size of the largest IP packet supported. This value should be set to the lowest value supported by any equipment in the transmission path.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..2048  

ty3250CfgSnmpTable 1.3.6.1.4.1.466.4.7
IP addresses and corresponding trap filters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250SnmpEntry

ty3250SnmpEntry 1.3.6.1.4.1.466.4.7.1
entry of IP addresses and corresponding trap filters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250SnmpEntry  

ty3250SnmpIndex 1.3.6.1.4.1.466.4.7.1.1
The index to one of the SNMP manager's address and filter configurations.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..6  

ty3250SnmpManagerIP 1.3.6.1.4.1.466.4.7.1.2
The IP address for the SNMP manager to receive this node's TRAPs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ty3250DiagT1Table 1.3.6.1.4.1.466.4.10
OBJECT IDENTIFIER    

ty3250DiagT1LocLineLpbk 1.3.6.1.4.1.466.4.10.1
Local Line Loopback on the T1 network port. Data and framing received from the network is transmitted back to the network
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER line-lpbk-disable(1), line-lpbk-enable(2)  

ty3250DiagT1LocPylLpbk 1.3.6.1.4.1.466.4.10.2
Local Payload Loopback on the T1 network port. Data (NOT framing) received from the network is reframed and transmitted back to the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pyl-lpbk-disable(1), pyl-lpbk-enable(2)  

ty3250DiagT1LocAggrLpbk 1.3.6.1.4.1.466.4.10.3
Local Aggregate Loopback on the T1 network port. Data from the DTE is framed for transmission and looped back through the network receiver towards the DTE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER aggr-lpbk-disable(1), aggr-lpbk-enable(2)  

ty3250DiagT1RmtLpbkStatus 1.3.6.1.4.1.466.4.10.4
Status of Remote Loopbacks received from the T1 network port. csu-lpbk-from-remote (1) indicates the node is in a Network Line Loopback state due to the reception of the CSU Loop-up pattern from the network. dsu-lpbk-from-remote (2) indicates the node is in a Network Line Loopback state due to the reception of the TyLink proprietary Loop-up pattern a remote node. pyl-lpbk-from-remote (3) indicates the node is in a Payload Loopback state due to the reception of the Facility Data Link's Loop-up pattern from the network (ESF only). csu-lpbk-sent-to-remote (4) indicates the node sent a csu loop up pattern to the remote. The node doesn't know if the loopback was accepted by the remote unit. dsu-lpbk-sent-to-remote (5) indicates the node sent a dsu loop up pattern to the remote. The node doesn't know if the loopback was accepted by the remote unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-remote-lpbks(1), csu-lpbk-from-remote(2), dsu-lpbk-from-remote(3), pyl-lpbk-from-remote(4), csu-lpbk-sent-to-remote(5), dsu-lpbk-sent-to-remote(6)  

ty3250DiagT1RmtLpbkCmd 1.3.6.1.4.1.466.4.10.5
Remote loopbacks that can be transmitted out the T1 network port. rmt-csu-lpbk-loopup (1) sends standard CSU loop up code into the network. rmt-csu-lpbk-loopdown (2) sends standard CSU loop down code into the network. rmt-dsu-lpbk-loopup (3) sends TyLink proprietary loop up code into the network. rmt-dsu-lpbk-loopdown (4) sends TyLink proprietary loop up code into the network.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER rmt-csu-lpbk-loopup(1), rmt-csu-lpbk-loopdown(2), rmt-dsu-lpbk-loopup(3), rmt-dsu-lpbk-loopdown(4)  

ty3250DiagDteTable 1.3.6.1.4.1.466.4.11
OBJECT IDENTIFIER    

ty3250DiagDteLocBidirLpbk 1.3.6.1.4.1.466.4.11.1
Local Bi-directional Loopback on the DTE port. Loops the clock and data back to the DTE at the interface on the 3250; also loops the DTE's network bandwidth back to the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER bidir-lpbk-disable(1), bidir-lpbk-enable(2)  

ty3250DiagDteRmtLpbkStatus 1.3.6.1.4.1.466.4.11.2
Status of Remote Loopbacks received for the DTE port. bidir-lpbk-from-remote indictaes that either a proprietary or V54 loop up pattern was received on the DTE's network bandwidth. bidir-lpbk-sent-to-remote indiactes that either a proprietary or V54 loop up pattern was sent to the remote DTE.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-remote-lpbks(1), bidir-lpbk-from-remote(2), bidir-lpbk-sent-to-remote(3)  

ty3250DiagDteRmtLpbkCmd 1.3.6.1.4.1.466.4.11.3
Remote loopbacks that can be transmitted to a remote DTE port rmt-bidir-lpbk-loopup-tyl (1) sends the TyLink proprietary loop up pattern to a remote TyLink DTE. When detected by the remote unit, a DTE Bidirectional Loopback is put up. rmt-bidir-lpbk-loopdown-tyl (2) sends the TyLink proprietary loop down pattern to a remote TyLink DTE. When detected by the remote unit, a DTE Bidirectional Loopback is torn down. rmt-bidir-lpbk-loopup-V54 (3) sends the standard V.54 loop up pattern to a remote, V54-compatible DTE. When detected by the remote unit, a DTE Bidirectional Loopback is put up. rmt-bidir-lpbk-loopdown-V54 (4) sends the standard V.54 loop down pattern to a remote, V54-compatible DTE. When detected by the remote unit, a DTE Bidirectional Loopback is torn down.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER rmt-bidir-lpbk-loopup-tyl(1), rmt-bidir-lpbk-loopdown-tyl(2), rmt-bidir-lpbk-loopup-v54(3), rmt-bidir-lpbk-loopdown-v54(4)  

ty3250DiagBerTable 1.3.6.1.4.1.466.4.12
OBJECT IDENTIFIER    

ty3250DiagBerPattrn 1.3.6.1.4.1.466.4.12.1
selects pseudorandom pattern for bit error rate test
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER pattrn-511(1), pattrn-qrss(2)  

ty3250DiagBerState 1.3.6.1.4.1.466.4.12.2
BERT test related actions: a: Starts a BERT test on selected bandwidth, b: Stops a BERT test on selected bandwidth, c: Inject Errors while the BERT test is running, d: Clears BERT test errors.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER enable-t1-bert-on-full-bw(1), enable-t1-bert-on-DTE-bw(2), disable-bert-test(3), inject-error-bert-test(4), clear-error-bert-test(5)  

ty3250DiagBerStatus 1.3.6.1.4.1.466.4.12.3
Displays the current BERT test sync status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bert-off(1), bert-full-bw-out-of-sync(2), bert-DTE-bw-out-of-sync(3), bert-full-bw-in-sync(4), bert-DTE-bw-in-sync(5)  

ty3250DiagBerErrors 1.3.6.1.4.1.466.4.12.4
Displays the number of errors detected in Bert Test.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ty3250DiagBerTimeElaps 1.3.6.1.4.1.466.4.12.5
Elapsed time since BERT test was started or cleared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

ty3250PortStatusTable 1.3.6.1.4.1.466.4.13
Status of a T1 or DTE port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250PortStatus

ty3250PortStatus 1.3.6.1.4.1.466.4.13.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250PortStatus  

ty3250IntfIndex 1.3.6.1.4.1.466.4.13.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250IntfType 1.3.6.1.4.1.466.4.13.1.2
Port type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER t1-port(1), dte-port(2)  

ty3250IntfMode 1.3.6.1.4.1.466.4.13.1.3
Status of the indexed port. Inactive (1) indicates the port has no connections. Active (2) indicates connections and data mode. Test-mode (3) indicates connections and diagnostic state for that port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2), test-mode(3)  

ty3250IntfStatus 1.3.6.1.4.1.466.4.13.1.4
Status of the indexed port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER t1-frame-sync-okay(1), t1-frame-sync-with-errors(2), signal-present-without-frame-sync(3), signal-not-present(4), not-applicable(5)  

ty3250IntfAlarms 1.3.6.1.4.1.466.4.13.1.5
Alarms present at the indexed port. The node software may not support DTE alarm conditions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no-alarms(1), red-alarm-declared(2), yellow-alarm-detected(3), unframed-all-ones-detected(4)  

ty3250PerfT1CurrentTable 1.3.6.1.4.1.466.4.14
The T1 performance numbers for the current 15 minute interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250T1CurrentEntry

ty3250T1CurrentEntry 1.3.6.1.4.1.466.4.14.1
An entry in the T1 Current Perf table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250T1CurrentEntry  

ty3250T1CurrentIndex 1.3.6.1.4.1.466.4.14.1.1
The index value which uniquely identifies the T1 interface to which this entry is applica- ble.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250T1CurrentCrc6Events 1.3.6.1.4.1.466.4.14.1.2
Count of CRC errors detected on an ESF framed circuit. In ESF framing a CRC is generated at the source, based upon the composite data. A CRC error indicates the presence of at least one bit error in an ESF superframe. This field is a free-running accumulation of CRC errors and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents. Not applicable if D4/SF framing is selcted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentOofEvents 1.3.6.1.4.1.466.4.14.1.3
Count of Out-of-Frame events on a T1 circuit. An out-of- frame event occurs when the frame synchronization criteria is lost and a resynchronization must occur. Data is interrupted during frame resynchronization. This field is a free-running accumulation of OOF transitions and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentESs 1.3.6.1.4.1.466.4.14.1.4
The number of Errored Seconds, encountered by a T1 interface in the current 15 minute inter- val. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentSESs 1.3.6.1.4.1.466.4.14.1.5
The number of Severely Errored Seconds encoun- tered by a t1 interface in the current 15 minute interval. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentSEFSs 1.3.6.1.4.1.466.4.14.1.6
The number of Severely Errored Framing Seconds encountered by a t1 interface in the current 15 minute interval. A SEFS is a one second interval with one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentUASs 1.3.6.1.4.1.466.4.14.1.7
The number of Unavailable Seconds encountered by a t1 interface in the current 15 minute in- terval. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentCSSs 1.3.6.1.4.1.466.4.14.1.8
The number of Controlled Slip Seconds encoun- tered by a t1 interface in the current 15 minute interval. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentBESs 1.3.6.1.4.1.466.4.14.1.9
The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval. A BES is a one second interval with more than one and less than 320 CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1CurrentLCVs 1.3.6.1.4.1.466.4.14.1.10
The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250PerfT1IntervalTable 1.3.6.1.4.1.466.4.15
The DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250T1IntervalEntry

ty3250T1IntervalEntry 1.3.6.1.4.1.466.4.15.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250T1IntervalEntry  

ty3250T1IntervalIndex 1.3.6.1.4.1.466.4.15.1.1
The index value which uniquely identifies the t1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a NetwLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250T1IntervalNumber 1.3.6.1.4.1.466.4.15.1.2
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes inter- val (assuming that all 96 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..96  

ty3250T1IntervalESs 1.3.6.1.4.1.466.4.15.1.3
The number of Errored Seconds encountered by a t1 interface in one of the previous 96, indi- vidual 15 minute, intervals. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalSESs 1.3.6.1.4.1.466.4.15.1.4
The number of Severely Errored Seconds encoun- tered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalSEFSs 1.3.6.1.4.1.466.4.15.1.5
The number of Severely Errored Framing Seconds encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A SEFS is a one second interval with one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalUASs 1.3.6.1.4.1.466.4.15.1.6
The number of Unavailable Seconds encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalCSSs 1.3.6.1.4.1.466.4.15.1.7
The number of Controlled Slip Seconds encoun- tered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalBESs 1.3.6.1.4.1.466.4.15.1.8
The number of Bursty Errored Seconds (BESs) encountered by a t1 interface in one of the previous 96, individual 15 minute, intervals. A BES is a one second interval with more than one and less than 320 CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1IntervalLCVs 1.3.6.1.4.1.466.4.15.1.9
The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250PerfT1TotalTable 1.3.6.1.4.1.466.4.16
The T1 Total table. 24 hour interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250T1TotalEntry

ty3250T1TotalEntry 1.3.6.1.4.1.466.4.16.1
An entry in the T1 Total table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250T1TotalEntry  

ty3250T1TotalIndex 1.3.6.1.4.1.466.4.16.1.1
The index value which uniquely identifies the t1 interface to which this entry is applica- ble. The interface identified by a particular value of this index is the same interface as identified by the same value as a NetwLineIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250T1TotalESs 1.3.6.1.4.1.466.4.16.1.2
The number of Errored Seconds encountered by a t1 interface in the previous 24 hour interval. An errored second is a one-second interval with CRC errors or a loss of frame sync occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalSESs 1.3.6.1.4.1.466.4.16.1.3
The number of Severely Errored Seconds encoun- tered by a t1 interface in the previous 24 hour interval. A severely errored second is a one second interval with more than 320 CRC errors or one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalSEFSs 1.3.6.1.4.1.466.4.16.1.4
The number of Severely Errored Framing Seconds 24 hour interval. A SEFS is a one second interval with one or more frame sync losses.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalUASs 1.3.6.1.4.1.466.4.16.1.5
The number of Unavailable Seconds encountered by a t1 interface in the previous 24 hour in- terval. A UAS is a one second interval during which the received signal is classified as 'unavailable due to excessive errors'. A signal is unavailable after receiving ten consective severely errored seconds and stays unavailable until ten seconds without a severely errored second occur.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalCSSs 1.3.6.1.4.1.466.4.16.1.6
The number of Controlled Slip Seconds encoun- tered by a t1 interface in the previous 24 hour interval. A controlled slip is the replication or deletion of a T1 frame at the receiver. These events often indicate a T1 network timing problem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalBESs 1.3.6.1.4.1.466.4.16.1.7
The number of Bursty Errored Seconds (BESs) encountered by a t1 interface in the previous 24 hour interval. A BES is a one second interval with more than one and less than 320 CRC errors.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1TotalLCVs 1.3.6.1.4.1.466.4.16.1.8
The number of Line Code Violations (LCVs) en- countered by a t1 interface in the current 15 minute interval. LCVs are non-B8ZS related violations of the alternate mark inversion protocol. An excessive count usually indicates a B8ZS/AMI configuration mismatch in the T1 network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

ty3250T1PerfCmdTypeTable 1.3.6.1.4.1.466.4.17
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ty3250T1PerfCmdType

ty3250T1PerfCmdType 1.3.6.1.4.1.466.4.17.1
An entry in the DS1 Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ty3250T1PerfCmdType  

ty3250T1CommandIndex 1.3.6.1.4.1.466.4.17.1.1
The index value which uniquely identifies the t1 interface to which this command is applica- ble.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER 1..4  

ty3250T1PerfFreezeState 1.3.6.1.4.1.466.4.17.1.2
This command halts the node's performance monitoring and freezes the current, interval, and total performance register values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER freeze-reg(1), unfreeze-reg(2)  

ty3250T1PerfClearEvents 1.3.6.1.4.1.466.4.17.1.3
This command resets all of the (user's) error event registers. This includes the CRC6 and Out-of-Frame counts. It does not affect the interval or 24 hour performance totals.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clear-events(1)  

ty3250T1PerfClearAll 1.3.6.1.4.1.466.4.17.1.4
This command resets all of the (user's) performance registers.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER clear-all(1)  

ty3250AlarmType 1.3.6.1.4.1.466.4.18
The type of alarms that are generated on the node
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cold-start(1), authentication(2), t1-netw-carrier-loss(3), t1-netw-carrier-detect(4), t1-netw-sync-loss-declare(5), t1-netw-sync-acquire(6), t1-netw-red-alarm-declare(7), t1-netw-red-alarm-clear(8), t1-netw-yellow-alarm-detect(9), t1-netw-yellow-alarm-clear(10), t1-netw-ais-detect(11), t1-netw-ais-clear(12), t1-controlled-slip(13), configuration-update(14), diagnostic-state(15), diagnostic-clear(16)  

ty3250Trap 0
A ty3250Trap trap signifies that the sending node had its `ty3250AlarmType` variable modified.
TRAP-TYPE    

ty3250coldstart 1
cold-start.
TRAP-TYPE    

ty3250authentication 2
authentication.
TRAP-TYPE    

ty3250t1netwcarrierloss 3
t1-netw-carrier-loss.
TRAP-TYPE    

ty3250t1netwcarrierdetect 4
t1-netw-carrier-detect.
TRAP-TYPE    

ty3250t1netwsynclossdeclare 5
t1-netw-sync-loss-declare.
TRAP-TYPE    

ty3250t1netwsyncacquire 6
t1-netw-sync-acquire.
TRAP-TYPE    

ty3250t1netwredalarmdeclare 7
t1-netw-red-alarm-declare.
TRAP-TYPE    

ty3250t1netwredalarmclear 8
t1-netw-red-alarm-clear.
TRAP-TYPE    

ty3250t1netwyellowalarmdetect 9
t1-netw-yellow-alarm-detect.
TRAP-TYPE    

ty3250t1netwyellowalarmclear 10
.
TRAP-TYPE    

ty3250t1netwaisdetect 11
t1-netw-ais-detect.
TRAP-TYPE    

ty3250t1netwaisclear 12
t1-netw-ais-clear.
TRAP-TYPE    

ty3250t1controlledslip 13
t1-controlled-slip.
TRAP-TYPE    

ty3250configurationupdate 14
configuration-update.
TRAP-TYPE    

ty3250diagnosticstate 15
diagnostic-state.
TRAP-TYPE    

ty3250diagnosticclear 16
diagnostic-clear.
TRAP-TYPE