TSMEXT-MIB

File: TSMEXT-MIB.mib (26639 bytes)

Imported modules

RFC-1212 XYLAN-BASE-MIB

Imported symbols

OBJECT-TYPE xylanTsmArch

Defined Types

MacAddress  
OCTET STRING Size(6)    

TsmAdminPortEntry  
SEQUENCE    
  tsmAdminPortSlotNumber INTEGER
  tsmAdminPortNumber INTEGER
  tsmAdminPortState INTEGER
  tsmAdminPortActiveMon INTEGER
  tsmAdminPortAcBitSet INTEGER
  tsmAdminPortConfigType INTEGER
  tsmAdminPortRingSpeed INTEGER
  tsmAdminPortPortMode INTEGER
  tsmAdminPortDuplex INTEGER
  tsmAdminPortSwMode INTEGER
  tsmAdminPortReset INTEGER

TsmAdminSwModeEntry  
SEQUENCE    
  tsmAdminSwModeSlotNumber INTEGER
  tsmAdminSwModeHiErrThresh INTEGER
  tsmAdminSwModeLoErrThresh INTEGER
  tsmAdminSwModeTrendThresh INTEGER
  tsmAdminSwModeSamplePeriod INTEGER
  tsmAdminSwModeReset INTEGER

TsmOperPortEntry  
SEQUENCE    
  tsmOperPortSlotNumber INTEGER
  tsmOperPortNumber INTEGER
  tsmOperPortState INTEGER
  tsmOperPortActiveMon INTEGER
  tsmOperPortAcBitSet INTEGER
  tsmOperPortConfigType INTEGER
  tsmOperPortRingSpeed INTEGER
  tsmOperPortPortMode INTEGER
  tsmOperPortDuplex INTEGER
  tsmOperPortSwMode INTEGER
  tsmOperPortAdaptSwMode INTEGER
  tsmOperPortAdaptErrRate INTEGER
  tsmOperPortAdaptTrend INTEGER
  tsmOperPortOpenState INTEGER
  tsmOperPortUpStream MacAddress

TsmOperSwModeEntry  
SEQUENCE    
  tsmOperSwModeSlotNumber INTEGER
  tsmOperSwModeHiErrThresh INTEGER
  tsmOperSwModeLoErrThresh INTEGER
  tsmOperSwModeTrendThresh INTEGER
  tsmOperSwModeSamplePeriod INTEGER

Defined Values

tsmExtensions 1.3.6.1.4.1.800.2.19.1
OBJECT IDENTIFIER    

tsmAdmin 1.3.6.1.4.1.800.2.19.1.1
OBJECT IDENTIFIER    

tsmOper 1.3.6.1.4.1.800.2.19.1.2
OBJECT IDENTIFIER    

tsmAdminPortTable 1.3.6.1.4.1.800.2.19.1.1.1
TSM Port Configuration Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsmAdminPortEntry

tsmAdminPortEntry 1.3.6.1.4.1.800.2.19.1.1.1.1
A TSM Port Configuration Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TsmAdminPortEntry  

tsmAdminPortSlotNumber 1.3.6.1.4.1.800.2.19.1.1.1.1.1
The slot number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmAdminPortNumber 1.3.6.1.4.1.800.2.19.1.1.1.1.2
The port number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmAdminPortState 1.3.6.1.4.1.800.2.19.1.1.1.1.3
The configured state of the port. 1 = enable. 2 = disable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tsmAdminPortActiveMon 1.3.6.1.4.1.800.2.19.1.1.1.1.4
The configured active monitor participation of the port. 1 = yes. Participate in the active monitor selection process. 2 = no. Do NOT participate in the active monitor selection process.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

tsmAdminPortAcBitSet 1.3.6.1.4.1.800.2.19.1.1.1.1.5
The configured control mode for handling the ARI/FCI Bits of the port. 1 = nonLocal. Set ARI/FCI bits on all non-local LLC frames repeated by the port. For local frames repeat the ARI/FCI bits just as they are received. 2 = repeat. Repeat ARI/FCI bit on all LLC frames just as they are received. 3 = always. Set ARI/FCI bits on all LLC frames repeated by the port. 4 = never. Do not set ARI/FCI bits on any LLC frames repeated by the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nonLocal(1), repeat(2), always(3), never(4)  

tsmAdminPortConfigType 1.3.6.1.4.1.800.2.19.1.1.1.1.6
The configured config-type of the port. 1 = auto. Automatically set the port's ring speed, mode, duplex and switching mode parameters. 2 = fixed. Use customer defined values for the port's ring speed, mode, duplex and switching mode parameters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), fixed(2)  

tsmAdminPortRingSpeed 1.3.6.1.4.1.800.2.19.1.1.1.1.7
The configured ring speed of the port. 1 = auto. Automatically set the port's ring speed. 2 = fourMegabit. Always set the port's ring speed at four megabits. 3 = sixteenMegabit. Always set the port's ring speed at sixteen megabits. This object may ONLY be set if the value of port's tsmAdminPortConfigType is fixed(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), fourMegabit(2), sixteenMegabit(3)  

tsmAdminPortPortMode 1.3.6.1.4.1.800.2.19.1.1.1.1.8
The configured port mode of the port. 1 = auto. Automatically sense the port mode. This value is set by the switch when the tsmAdminPortConfigMode is set to auto. This object CANNOT be changed to auto by an SNMP SET. 2 = portMode. Only a dedicated connection to a station is supported. 3 = adapterMode. The port operates like a station. The connection can be either dedicated or shared. This object may ONLY be set if the value of port's tsmAdminPortConfigType is fixed(1). auto(1) is NOT a valid SET value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), portMode(2), adapterMode(3)  

tsmAdminPortDuplex 1.3.6.1.4.1.800.2.19.1.1.1.1.9
The configured duplex mode of the port. 1 = auto. Automatically set the port's duplex mode. 2 = halfDuplex. Alway run the port in half duplex mode. 3 = fullDuplex. Alway run the port in full duplex mode. This object may ONLY be set if the value of port's tsmAdminPortConfigType is fixed(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), halfDuplex(2), fullDuplex(3)  

tsmAdminPortSwMode 1.3.6.1.4.1.800.2.19.1.1.1.1.10
The configured duplex mode of the port. 1 = cutThrough. A scheme that allows frame transmission to begin at the output port prior to end-of-frame reception at the input port. 2 = storeAndForward. The entire packet is received and stored before switching begins. 3 = adaptive. Alternate between cut-through and store-and-forward base on the specified error threshold.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER cutThrough(1), storeAndForward(2), adaptive(3)  

tsmAdminPortReset 1.3.6.1.4.1.800.2.19.1.1.1.1.11
This object is used to reset the port. 1 = ready. The port is ready to be reset. 2 = reset. Reset the port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), reset(2)  

tsmAdminSwModeTable 1.3.6.1.4.1.800.2.19.1.1.2
TSM Switching Mode Configuration Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsmAdminSwModeEntry

tsmAdminSwModeEntry 1.3.6.1.4.1.800.2.19.1.1.2.1
A TSM Switching Mode Configuration Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TsmAdminSwModeEntry  

tsmAdminSwModeSlotNumber 1.3.6.1.4.1.800.2.19.1.1.2.1.1
The slot number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmAdminSwModeHiErrThresh 1.3.6.1.4.1.800.2.19.1.1.2.1.2
The high error threshold in percent for all ports associated with the TSM which are configured to run in adaptive mode. If the percentage of errors in a sampling period meets or exceeds this value, the port's switching mode will change from cut-through to store-and-forward mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

tsmAdminSwModeLoErrThresh 1.3.6.1.4.1.800.2.19.1.1.2.1.3
The low error threshold in percent for all ports associated with the TSM which are configured to run in adaptive mode. If the percentage of errors in a sampling period falls below this value, the port's switching mode will change from store-and-forward to cut-through mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

tsmAdminSwModeTrendThresh 1.3.6.1.4.1.800.2.19.1.1.2.1.4
The error rate trend threshold in percent for all ports associated with the TSM which are configured to run in adaptive mode. When the percentage of errors is between the high and low error thresholds AND the port is currently running in cut-through mode, the error rate trend which is the difference in errors between two sampling periods is compared to the error rate trend threshold. If the error rate trend is greater than this value, the port's switching mode will change from cut-through mode to store-and-forward. The error rate trend threshold should be no greater than the difference between the high and low threshold values.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

tsmAdminSwModeSamplePeriod 1.3.6.1.4.1.800.2.19.1.1.2.1.5
The sampling period in seconds for all ports associated with the TSM which are configured to run in adaptive mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..120  

tsmAdminSwModeReset 1.3.6.1.4.1.800.2.19.1.1.2.1.6
This object is used to reset the TSM. 1 = ready. The TSM is ready to be reset. 2 = reset. Reset the TSM.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ready(1), reset(2)  

tsmOperPortTable 1.3.6.1.4.1.800.2.19.1.2.1
TSM Port Operational Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsmOperPortEntry

tsmOperPortEntry 1.3.6.1.4.1.800.2.19.1.2.1.1
A TSM Port Operational Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TsmOperPortEntry  

tsmOperPortSlotNumber 1.3.6.1.4.1.800.2.19.1.2.1.1.1
The slot number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmOperPortNumber 1.3.6.1.4.1.800.2.19.1.2.1.1.2
The port number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmOperPortState 1.3.6.1.4.1.800.2.19.1.2.1.1.3
The operational state of the port. 1 = enable. 2 = disable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

tsmOperPortActiveMon 1.3.6.1.4.1.800.2.19.1.2.1.1.4
The operational active monitor participation of the port. 1 = yes. Participate in the active monitor selection process. 2 = no. Do NOT participate in the active monitor selection process.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

tsmOperPortAcBitSet 1.3.6.1.4.1.800.2.19.1.2.1.1.5
The operational control mode for handling the ARI/FCI Bits of the port. 1 = nonLocal. Set ARI/FCI bits on all non-local LLC frames repeated by the port. For local frames repeat the ARI/FCI bits just as they are received. 2 = repeat. Repeat ARI/FCI bit on all LLC frames just as they are received. 3 = always. Set ARI/FCI bits on all LLC frames repeated by the port. 4 = never. Do not set ARI/FCI bits on any LLC frames repeated by the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER nonLocal(1), repeat(2), always(3), never(4)  

tsmOperPortConfigType 1.3.6.1.4.1.800.2.19.1.2.1.1.6
The operational config-type of the port. 1 = auto. Automatically set the port's ring speed, mode and duplex parameters. 2 = fixed. Use customer defined values for the port's ring speed, mode and duplex parameters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), fixed(2)  

tsmOperPortRingSpeed 1.3.6.1.4.1.800.2.19.1.2.1.1.7
The operational ring speed of the port. 1 = auto. The port has not yet automatically set the ring speed. 2 = fourMegabit. 3 = sixteenMegabit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), fourMegabit(2), sixteenMegabit(3)  

tsmOperPortPortMode 1.3.6.1.4.1.800.2.19.1.2.1.1.8
The operational port mode of the port. 1 = auto. Automatically sense the port mode. 2 = portMode. Only a dedicated connection to a station is supported. 3 = adapterMode. The port operates like a station. The connection can be either dedicated or shared.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), portMode(2), adapterMode(3)  

tsmOperPortDuplex 1.3.6.1.4.1.800.2.19.1.2.1.1.9
The configured duplex mode of the port. 1 = auto. The port has not yet automatically set the port's duplex mode. 2 = halfDuplex. 3 = fullDuplex.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER auto(1), halfDuplex(2), fullDuplex(3)  

tsmOperPortSwMode 1.3.6.1.4.1.800.2.19.1.2.1.1.10
The configured switch mode of the port. 1 = cutThrough. A scheme that allows frame transmission to begin at the output port prior to end-of-frame reception at the input port. 2 = storeAndForward. The entire packet is received and stored before switching begins. 3 = adaptive. Alternate between cut-through and store-and-forward base on the specified error threshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cutThrough(1), storeAndForward(2), adaptive(3)  

tsmOperPortAdaptSwMode 1.3.6.1.4.1.800.2.19.1.2.1.1.11
The operational adaptive switch mode of the port. 1 = cutThrough. A scheme that allows frame transmission to begin at the output port prior to end-of-frame reception at the input port. 2 = storeAndForward. The entire packet is received and stored before switching begins. 3 = notAdaptive. The port is not running in adaptive mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER cutThrough(1), storeAndForward(2), notAdaptive(3)  

tsmOperPortAdaptErrRate 1.3.6.1.4.1.800.2.19.1.2.1.1.12
The operational adaptive error rate in percent of the port. This value is the percent of errors in the last sampling period.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmOperPortAdaptTrend 1.3.6.1.4.1.800.2.19.1.2.1.1.13
The operational adaptive error rate trend in percent of the port. This value is the difference in errors between the last two sampling periods.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmOperPortOpenState 1.3.6.1.4.1.800.2.19.1.2.1.1.14
The operational open status of the port. 1 = opened 2 = closed 3 = opening 4 = closing 5 = openFailure 6 = ringFailure
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER opened(1), closed(2), opening(3), closing(4), openFailure(5), ringFailure(6)  

tsmOperPortUpStream 1.3.6.1.4.1.800.2.19.1.2.1.1.15
The operational MAC Address of the up stream neighbour in the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  MacAddress  

tsmOperSwModeTable 1.3.6.1.4.1.800.2.19.1.2.2
TSM Switch Mode Operational Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TsmOperSwModeEntry

tsmOperSwModeEntry 1.3.6.1.4.1.800.2.19.1.2.2.1
A TSM Port Operational Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TsmOperSwModeEntry  

tsmOperSwModeSlotNumber 1.3.6.1.4.1.800.2.19.1.2.2.1.1
The slot number of the Token Ring Switching Module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

tsmOperSwModeHiErrThresh 1.3.6.1.4.1.800.2.19.1.2.2.1.2
The operational high error threshold for all ports associated with the TSM which are configured to run in adaptive mode. If the percentage of errors in a sampling period meets or exceeds this value, the port's switching mode will change from cut-through to store-and-forward mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tsmOperSwModeLoErrThresh 1.3.6.1.4.1.800.2.19.1.2.2.1.3
The operational low error threshold for all ports associated with the TSM which are configured to run in adaptive mode. If the percentage of errors in a sampling period falls below this value, the port's switching mode will change from store-and-forward to cut-through mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tsmOperSwModeTrendThresh 1.3.6.1.4.1.800.2.19.1.2.2.1.4
The operational error rate trend threshold in percent for all ports associated with the TSM which are configured to run in adaptive mode. When the percentage of errors is between the high and low error thresholds AND the port is currently running in cut-through mode, the error rate trend which is the difference in errors between two sampling periods is compared to the error rate trend threshold. If the error rate trend is greater than this value, the port's switching mode will change from cut-through mode to store-and-forward.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

tsmOperSwModeSamplePeriod 1.3.6.1.4.1.800.2.19.1.2.2.1.5
The operational sampling period in seconds for all ports associated with the TSM which are configured to run in adaptive mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..120