TSL-MIB

File: TSL-MIB.mib (11014 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC-1215

Imported symbols

enterprises Opaque OBJECT-TYPE
TRAP-TYPE

Defined Types

DisplayString  
OCTET STRING    

AlarmEntry  
SEQUENCE    
  alarmTableIndex INTEGER
  alarmType INTEGER
  alarmIndex INTEGER
  alarmText DisplayString
  alarmState INTEGER
  alarmPolarity INTEGER
  alarmData Opaque

MduOutputEntry  
SEQUENCE    
  mduOutputIndex INTEGER
  mduOutputState INTEGER
  mduOutputDelay INTEGER
  mduOutputlowerCurrent INTEGER
  mduOutputupperCurrent INTEGER
  mduOutputCurrent INTEGER
  mduOutputpowerFactor INTEGER
  mduOutputVA INTEGER
  mduOutputWatts INTEGER
  mduOutputCal INTEGER

Defined Values

tslMIB 1.3.6.1.4.1.6853
OBJECT IDENTIFIER    

alarm 1.3.6.1.4.1.6853.2
OBJECT IDENTIFIER    

alarmIdent 1.3.6.1.4.1.6853.2.1
Equipment alarms description and version
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmTable 1.3.6.1.4.1.6853.2.2
The table of alarm entries
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmEntry

alarmEntry 1.3.6.1.4.1.6853.2.2.1
An alarm entry in the table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AlarmEntry  

alarmTableIndex 1.3.6.1.4.1.6853.2.2.1.1
The index into the table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..28  

alarmType 1.3.6.1.4.1.6853.2.2.1.2
Alarm type
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER internal(1), gpi(2), outputFail(3), psuFail(4), currentAlarm(5)  

alarmIndex 1.3.6.1.4.1.6853.2.2.1.3
Alarm type number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmText 1.3.6.1.4.1.6853.2.2.1.4
Alarm description
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

alarmState 1.3.6.1.4.1.6853.2.2.1.5
Alarm state
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

alarmPolarity 1.3.6.1.4.1.6853.2.2.1.6
Alarm active polarity (notApplicable for non-gpi alarms)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), normallyOpen(2), normallyClosed(3)  

alarmData 1.3.6.1.4.1.6853.2.2.1.7
Additional alarm data of variable length, according to alarm type.
Status: optional Access: read-only
OBJECT-TYPE    
  Opaque  

alarmTotal 1.3.6.1.4.1.6853.2.3
The total number of alarms in the table
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmLocation 1.3.6.1.4.1.6853.2.4
The physical location of the equipment generating the alarm
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

alarmEqptTemp 1.3.6.1.4.1.6853.2.5
Equipment temperature (in degrees Centigrade)
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

alarmEqptTempHi 1.3.6.1.4.1.6853.2.6
Equipment temperature alarm point (degrees Centigrade)
Status: optional Access: read-write
OBJECT-TYPE    
  INTEGER  

alarmTrap 4
An entry in the alarm table has changed state
TRAP-TYPE    

alarmEqptTempHiTrap 5
The equipment temperature has exceeded the maximum allowed
TRAP-TYPE    

alarmEqptTempOkTrap 6
The equipment temperature is now within limits
TRAP-TYPE    

mdu12 1.3.6.1.4.1.6853.3
OBJECT IDENTIFIER    

mdu12Ident 1.3.6.1.4.1.6853.3.1
Equipment description and version
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

mduPowerOn 1.3.6.1.4.1.6853.3.2
MDU power-on output sequence
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER simultaneous(1), sequential(2), delayed(3)  

mduSeqDelay 1.3.6.1.4.1.6853.3.3
Sequential mode delay between outputs
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduOutputTable 1.3.6.1.4.1.6853.3.4
Table of output controls
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MduOutputEntry

mduOutputEntry 1.3.6.1.4.1.6853.3.4.1
An entry in the output table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MduOutputEntry  

mduOutputIndex 1.3.6.1.4.1.6853.3.4.1.1
Output number
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..12  

mduOutputState 1.3.6.1.4.1.6853.3.4.1.2
MDU Output status
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), locked-Off(3), locked-On(4)  

mduOutputDelay 1.3.6.1.4.1.6853.3.4.1.3
Output on delay from power on (Delay mode only)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduOutputlowerCurrent 1.3.6.1.4.1.6853.3.4.1.4
Lower current limit for output
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduOutputupperCurrent 1.3.6.1.4.1.6853.3.4.1.5
Upper current limit for output
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduOutputCurrent 1.3.6.1.4.1.6853.3.4.1.6
Output current
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mduOutputpowerFactor 1.3.6.1.4.1.6853.3.4.1.7
Output power factor
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mduOutputVA 1.3.6.1.4.1.6853.3.4.1.8
Output apparent power
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mduOutputWatts 1.3.6.1.4.1.6853.3.4.1.9
Output real power
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mduOutputCal 1.3.6.1.4.1.6853.3.4.1.10
Output current measure calibration data
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduPowerStatus 1.3.6.1.4.1.6853.3.5
Status of MDU power inlets
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER totalLoss(1), input1OK(2), input2OK(3), allOk(4)  

mduVoltageCal 1.3.6.1.4.1.6853.3.6
Voltage measure calibration data
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduVoltage 1.3.6.1.4.1.6853.3.7
Voltage measurement
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mduVoltageFloor 1.3.6.1.4.1.6853.3.8
Voltage lower limit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduVoltageLimit 1.3.6.1.4.1.6853.3.9
Voltage upper limit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduTotalCurrent 1.3.6.1.4.1.6853.3.10
Total current measurement
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduCurrentLimit 1.3.6.1.4.1.6853.3.11
Current total limit
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mduAuxRly1 1.3.6.1.4.1.6853.3.12
Auxiliary Relay 1 state
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

mduAuxRly2 1.3.6.1.4.1.6853.3.13
Auxiliary Relay 2 state
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

mduPowerStatusTrap 7
The power input to the MDU has changed state
TRAP-TYPE    

mduVoltageStatusTrap 8
The voltage to the MDU has traversed a limit
TRAP-TYPE    

mduTotalCurrentStatusTrap 9
The total current through the MDU has traversed a limit
TRAP-TYPE