TSL-MIB
File:
TSL-MIB.mib (11014 bytes)
Imported modules
Imported symbols
Defined Types
AlarmEntry |
|
SEQUENCE |
|
|
|
|
alarmTableIndex |
INTEGER |
|
|
alarmType |
INTEGER |
|
|
alarmIndex |
INTEGER |
|
|
alarmText |
DisplayString |
|
|
alarmState |
INTEGER |
|
|
alarmPolarity |
INTEGER |
|
|
alarmData |
Opaque |
|
MduOutputEntry |
|
SEQUENCE |
|
|
|
|
mduOutputIndex |
INTEGER |
|
|
mduOutputState |
INTEGER |
|
|
mduOutputDelay |
INTEGER |
|
|
mduOutputlowerCurrent |
INTEGER |
|
|
mduOutputupperCurrent |
INTEGER |
|
|
mduOutputCurrent |
INTEGER |
|
|
mduOutputpowerFactor |
INTEGER |
|
|
mduOutputVA |
INTEGER |
|
|
mduOutputWatts |
INTEGER |
|
|
mduOutputCal |
INTEGER |
|
Defined Values
tslMIB |
1.3.6.1.4.1.6853 |
OBJECT IDENTIFIER |
|
|
|
alarm |
1.3.6.1.4.1.6853.2 |
OBJECT IDENTIFIER |
|
|
|
alarmIdent |
1.3.6.1.4.1.6853.2.1 |
Equipment alarms description and version |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
alarmTable |
1.3.6.1.4.1.6853.2.2 |
The table of alarm entries |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AlarmEntry |
|
alarmEntry |
1.3.6.1.4.1.6853.2.2.1 |
An alarm entry in the table |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AlarmEntry |
|
|
alarmTableIndex |
1.3.6.1.4.1.6853.2.2.1.1 |
The index into the table |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..28 |
|
alarmType |
1.3.6.1.4.1.6853.2.2.1.2 |
Alarm type |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
internal(1), gpi(2), outputFail(3), psuFail(4), currentAlarm(5) |
|
alarmIndex |
1.3.6.1.4.1.6853.2.2.1.3 |
Alarm type number |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
alarmText |
1.3.6.1.4.1.6853.2.2.1.4 |
Alarm description |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
alarmState |
1.3.6.1.4.1.6853.2.2.1.5 |
Alarm state |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
inactive(1), active(2) |
|
alarmPolarity |
1.3.6.1.4.1.6853.2.2.1.6 |
Alarm active polarity (notApplicable for non-gpi alarms) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notApplicable(1), normallyOpen(2), normallyClosed(3) |
|
alarmData |
1.3.6.1.4.1.6853.2.2.1.7 |
Additional alarm data of variable length, according to alarm type. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Opaque |
|
|
alarmTotal |
1.3.6.1.4.1.6853.2.3 |
The total number of alarms in the table |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
alarmLocation |
1.3.6.1.4.1.6853.2.4 |
The physical location of the equipment generating the alarm |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
alarmEqptTemp |
1.3.6.1.4.1.6853.2.5 |
Equipment temperature (in degrees Centigrade) |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
alarmEqptTempHi |
1.3.6.1.4.1.6853.2.6 |
Equipment temperature alarm point (degrees Centigrade) |
Status: optional |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
alarmTrap |
4 |
An entry in the alarm table has changed state |
TRAP-TYPE |
|
|
|
mdu12 |
1.3.6.1.4.1.6853.3 |
OBJECT IDENTIFIER |
|
|
|
mdu12Ident |
1.3.6.1.4.1.6853.3.1 |
Equipment description and version |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
mduPowerOn |
1.3.6.1.4.1.6853.3.2 |
MDU power-on output sequence |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
simultaneous(1), sequential(2), delayed(3) |
|
mduSeqDelay |
1.3.6.1.4.1.6853.3.3 |
Sequential mode delay between outputs |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputTable |
1.3.6.1.4.1.6853.3.4 |
Table of output controls |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
MduOutputEntry |
|
mduOutputEntry |
1.3.6.1.4.1.6853.3.4.1 |
An entry in the output table |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
MduOutputEntry |
|
|
mduOutputIndex |
1.3.6.1.4.1.6853.3.4.1.1 |
Output number |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..12 |
|
mduOutputState |
1.3.6.1.4.1.6853.3.4.1.2 |
MDU Output status |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2), locked-Off(3), locked-On(4) |
|
mduOutputDelay |
1.3.6.1.4.1.6853.3.4.1.3 |
Output on delay from power on (Delay mode only) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputlowerCurrent |
1.3.6.1.4.1.6853.3.4.1.4 |
Lower current limit for output |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputupperCurrent |
1.3.6.1.4.1.6853.3.4.1.5 |
Upper current limit for output |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputCurrent |
1.3.6.1.4.1.6853.3.4.1.6 |
Output current |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputpowerFactor |
1.3.6.1.4.1.6853.3.4.1.7 |
Output power factor |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputVA |
1.3.6.1.4.1.6853.3.4.1.8 |
Output apparent power |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputWatts |
1.3.6.1.4.1.6853.3.4.1.9 |
Output real power |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduOutputCal |
1.3.6.1.4.1.6853.3.4.1.10 |
Output current measure calibration data |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduPowerStatus |
1.3.6.1.4.1.6853.3.5 |
Status of MDU power inlets |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
totalLoss(1), input1OK(2), input2OK(3), allOk(4) |
|
mduVoltageCal |
1.3.6.1.4.1.6853.3.6 |
Voltage measure calibration data |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduVoltage |
1.3.6.1.4.1.6853.3.7 |
Voltage measurement |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduVoltageFloor |
1.3.6.1.4.1.6853.3.8 |
Voltage lower limit |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduVoltageLimit |
1.3.6.1.4.1.6853.3.9 |
Voltage upper limit |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduTotalCurrent |
1.3.6.1.4.1.6853.3.10 |
Total current measurement |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduCurrentLimit |
1.3.6.1.4.1.6853.3.11 |
Current total limit |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
mduAuxRly1 |
1.3.6.1.4.1.6853.3.12 |
Auxiliary Relay 1 state |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
mduAuxRly2 |
1.3.6.1.4.1.6853.3.13 |
Auxiliary Relay 2 state |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|