TRANGO-APEX-RF-MIB

File: TRANGO-APEX-RF-MIB.mib (6675 bytes)

Imported modules

TRANGO-APEX-MIB SNMPv2-TC SNMPv2-CONF
SNMPv2-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE OBJECT-IDENTITY
NOTIFICATION-TYPE apex DisplayString
MODULE-COMPLIANCE Counter32 Opaque

Defined Values

rf 1.3.6.1.4.1.5454.1.60.3
OBJECT IDENTIFIER    

atpc 1.3.6.1.4.1.5454.1.60.3.1
OBJECT IDENTIFIER    

rfATPCEnable 1.3.6.1.4.1.5454.1.60.3.1.1
Enable/Disable Automatic Transmit Power Control
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

rfATPCMaxPower 1.3.6.1.4.1.5454.1.60.3.1.2
Maximum ATPC power
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

rfATPCStepSize 1.3.6.1.4.1.5454.1.60.3.1.3
ATPC step size for each of the increment/decrement
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER Size(1..5)  

txfreq 1.3.6.1.4.1.5454.1.60.3.2
OBJECT IDENTIFIER    

rfTxFrequency 1.3.6.1.4.1.5454.1.60.3.2.1
Set/Display the current TX frequency
Status: current Access: read-write
OBJECT-TYPE    
  Opaque  

rfTxFrequencyInt 1.3.6.1.4.1.5454.1.60.3.2.2
Set/Display the current TX frequency in integer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

rxfreq 1.3.6.1.4.1.5454.1.60.3.3
OBJECT IDENTIFIER    

rfRxFrequency 1.3.6.1.4.1.5454.1.60.3.3.1
Display the current RX frequency
Status: current Access: read-only
OBJECT-TYPE    
  Opaque  

rfRxFrequencyInt 1.3.6.1.4.1.5454.1.60.3.3.2
Display the current RX frequency in integer
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

speed 1.3.6.1.4.1.5454.1.60.3.4
OBJECT IDENTIFIER    

rfSymrate 1.3.6.1.4.1.5454.1.60.3.4.1
Set/Display the current Symbol Rate
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER rate8(2), rate12(3), rate17(4), rate26(5), rate35(6), rate43(7), rate49(8)  

rfModulation 1.3.6.1.4.1.5454.1.60.3.4.2
Set/Display the current modulation
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER qpsk(0), q16q(1), q32q(2), q64q(3), q128q(4), q256q(5)  

rfBPF 1.3.6.1.4.1.5454.1.60.3.4.3
Display the current bandpass filter value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

rfChannelWidth 1.3.6.1.4.1.5454.1.60.3.4.4
Display the current channel width
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER bw10(0), bw20(1), bw28(2), bw40(3), bw50(4), bw80(5)  

power 1.3.6.1.4.1.5454.1.60.3.5
OBJECT IDENTIFIER    

rfPower 1.3.6.1.4.1.5454.1.60.3.5.1
Set/Display the current power
Status: current Access: read-write
OBJECT-TYPE    
  Opaque  

rfPowerInt 1.3.6.1.4.1.5454.1.60.3.5.2
Set/Display the current power in integer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

rfRSSILEDEnable 1.3.6.1.4.1.5454.1.60.3.6
Enable/Disable ODU LED display for RSSI
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

rfTemp 1.3.6.1.4.1.5454.1.60.3.7
Read current system Temperature
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

target 1.3.6.1.4.1.5454.1.60.3.8
OBJECT IDENTIFIER    

rfTargetRSSI 1.3.6.1.4.1.5454.1.60.3.8.1
Set/Disable the current Target RSSI value in float value
Status: current Access: read-write
OBJECT-TYPE    
  Opaque  

rfTargetRSSIInt 1.3.6.1.4.1.5454.1.60.3.8.2
Set/Disable the current Target RSSI value in integer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER  

rssi 1.3.6.1.4.1.5454.1.60.3.9
OBJECT IDENTIFIER    

rfRSSI 1.3.6.1.4.1.5454.1.60.3.9.1
Read current RSSI value
Status: current Access: read-only
OBJECT-TYPE    
  Opaque  

rfRSSIInt 1.3.6.1.4.1.5454.1.60.3.9.2
Read current RSSI value in Integer
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

rfPll 1.3.6.1.4.1.5454.1.60.3.10
OBJECT IDENTIFIER    

rfRFMRFpll 1.3.6.1.4.1.5454.1.60.3.10.1
RFM RX PLL lock status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nolock(0), lock(1)  

rfRFMIFpll 1.3.6.1.4.1.5454.1.60.3.10.2
RFM RX PLL lock status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nolock(0), lock(1)  

rfTransmitPll 1.3.6.1.4.1.5454.1.60.3.10.3
Transmit PLL lock status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nolock(0), lock(1)  

rfReceviedPll 1.3.6.1.4.1.5454.1.60.3.10.4
Loopback PLL lock status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER nolock(0), lock(1)  

rfIn 1.3.6.1.4.1.5454.1.60.3.11
OBJECT IDENTIFIER    

rfInDataOctets 1.3.6.1.4.1.5454.1.60.3.11.1
Display total number of incoming Octets in FPGA
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rfInDataPackets 1.3.6.1.4.1.5454.1.60.3.11.2
Display total number of incoming Packets in FPGA
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rfInDropPackets 1.3.6.1.4.1.5454.1.60.3.11.3
Display total number of Ethernet drop packets goes in toFPGA
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rfInPortUtil 1.3.6.1.4.1.5454.1.60.3.11.4
Display current in port utilizaition percentage
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

rfInPortRate 1.3.6.1.4.1.5454.1.60.3.11.5
Display current in port rate
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

rfOut 1.3.6.1.4.1.5454.1.60.3.12
OBJECT IDENTIFIER    

rfOutDataOctets 1.3.6.1.4.1.5454.1.60.3.12.1
Display total number of outgoing Octets in FPGA
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rfOutDataPackets 1.3.6.1.4.1.5454.1.60.3.12.2
Display total number of outgoing Packets in FPGA
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

rfOutPortUtil 1.3.6.1.4.1.5454.1.60.3.12.3
Display current out port utilizaition percentage
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

rfOutPortRate 1.3.6.1.4.1.5454.1.60.3.12.4
Display current out port rate
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER