TPLINK-SYSTOOL-MIB

File: TPLINK-SYSTOOL-MIB.mib (3760 bytes)

Imported modules

SNMPv2-SMI TPLINK-MIB

Imported symbols

OBJECT-TYPE tplinkMgmt

Defined Values

tplinkSysToolMIB 1.3.6.1.4.1.11863.6.3
This MIB module contain a collection of managed objects that apply to network devices.
MODULE-IDENTITY    

tplinkSysToolMIBObjects 1.3.6.1.4.1.11863.6.3.1
OBJECT IDENTIFIER    

tplinkSysToolNotifications 1.3.6.1.4.1.11863.6.3.2
OBJECT IDENTIFIER    

tpSysToolReBoot 1.3.6.1.4.1.11863.6.3.1.1
this used to determine whether to reboot or not
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notReBoot(0), reboot(1), reBootAndSave(2)  

tpSysToolReSet 1.3.6.1.4.1.11863.6.3.1.2
this used to determine whether to reset or not
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notReSet(0), reSet(1)  

tpSysToolConfigSave 1.3.6.1.4.1.11863.6.3.1.3
This object use to save the current config.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER commit(1)  

tpSysToolReBootSchedule 1.3.6.1.4.1.11863.6.3.1.4
OBJECT IDENTIFIER    

scheduleStatus 1.3.6.1.4.1.11863.6.3.1.4.1
Reboot Schedule Status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

scheduleIn 1.3.6.1.4.1.11863.6.3.1.4.2
this used to config the reboot schedule time interval
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..43200  

scheduleAt 1.3.6.1.4.1.11863.6.3.1.4.3
this used to config the reboot schedule time For example, Saturday Aug 18, 2015 at 08:18 would be given as: 18/08/2015-08:18
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

saveBeforeReboot 1.3.6.1.4.1.11863.6.3.1.4.4
Save the user config before reboot
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER no(0), yes(1)  

scheduleCancel 1.3.6.1.4.1.11863.6.3.1.4.5
Cancel the reboot schedule
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER commit(1)  

flash 1.3.6.1.4.1.11863.6.3.2.1
A flash notification is sented when the flash has been modified.
Status: current Access: read-create
NOTIFICATION-TYPE    

power 1.3.6.1.4.1.11863.6.3.2.2
A power notification is sented when the Redundant Power Supply or the Power Supply Module status changed.
Status: current Access: read-create
NOTIFICATION-TYPE    

fan 1.3.6.1.4.1.11863.6.3.2.3
A fan notification is sented when the Fan working mode or status changed.
Status: current Access: read-create
NOTIFICATION-TYPE    

temperature 1.3.6.1.4.1.11863.6.3.2.4
A temperature notification is sented when the temperature alarm happens or cancels.
Status: current Access: read-create
NOTIFICATION-TYPE    

mCard 1.3.6.1.4.1.11863.6.3.2.5
A mCard notification is sented when the mCard is inserted or removed.
Status: current Access: read-create
NOTIFICATION-TYPE