TIARA-HSSI-MIB

File: TIARA-HSSI-MIB.mib (13581 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC RFC-1215
TIARA-NETWORKS-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Counter32 TruthValue TRAP-TYPE
tiaraInterfaces

Defined Types

HssiConfigTableEntry  
SEQUENCE    
  hssiIfIndex INTEGER
  hssiConfigClockRate Integer32 1000000..52000000
  hssiConfigClockSource INTEGER
  hssiConfigTxClockSource INTEGER
  hssiConfigRxClockSource INTEGER
  hssiConfigMode INTEGER
  hssiConfigDataMode INTEGER
  hssiConfigCRC INTEGER
  hssiConfigProcessCtrlSignal INTEGER
  hssiDteLoopback TruthValue
  hssiDceLoopbackTest INTEGER

HssiStatsTableEntry  
SEQUENCE    
  hssiStatsAlarmStatus BITS
  hssiStatsFramesIn Counter32
  hssiStatsFramesOut Counter32
  hssiStatsOctetsIn Counter32
  hssiStatsOctetsOut Counter32
  hssiStatsCRCErrors Counter32

Defined Values

tiaraHssiMib 1.3.6.1.4.1.3174.2.7.2
MIB definitions for Tiara HSSI modules.
MODULE-IDENTITY    

hssiConfigTable 1.3.6.1.4.1.3174.2.7.2.1
The HSSI interface configurable parameters are listed in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HssiConfigTableEntry

hssiConfigTableEntry 1.3.6.1.4.1.3174.2.7.2.1.1
HSSI table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  HssiConfigTableEntry  

hssiIfIndex 1.3.6.1.4.1.3174.2.7.2.1.1.1
An integer value that is an index in the entries of the ifTable (MIB-II) with a HSSI interface type.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

hssiConfigClockRate 1.3.6.1.4.1.3174.2.7.2.1.1.2
Configures the clock rate (in Hertz) for the HSSI interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1000000..52000000  

hssiConfigClockSource 1.3.6.1.4.1.3174.2.7.2.1.1.3
Configures the clock source for the HSSI interface to either internal or line.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), line(2)  

hssiConfigTxClockSource 1.3.6.1.4.1.3174.2.7.2.1.1.4
Configures the transmit clock source for the HSSI interface to either internal or terminal. This variable is valid only for the HSSI interface on the USSI card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normalinternal(1), normalterminal(2), invertedinternal(3), invertedterminal(4)  

hssiConfigRxClockSource 1.3.6.1.4.1.3174.2.7.2.1.1.5
Configures the receive clock source for the HSSI interface to either internal or terminal. This variable is valid only for the HSSI interface on the USSI card
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normalinternal(1), normalterminal(2), invertedinternal(3), invertedterminal(4)  

hssiConfigMode 1.3.6.1.4.1.3174.2.7.2.1.1.6
Configures the mode for the HSSI to either DCE or DTE.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dce(1), dte(2)  

hssiConfigDataMode 1.3.6.1.4.1.3174.2.7.2.1.1.7
Configures the data mode for the HSSI interface. This variable is valid only for the HSSI interface on the USSI card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), inverted(2)  

hssiConfigCRC 1.3.6.1.4.1.3174.2.7.2.1.1.8
Configures the cyclic redundancy check for the HSSI interface to either 16 or 32 bits.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER crc16(1), crc32(2)  

hssiConfigProcessCtrlSignal 1.3.6.1.4.1.3174.2.7.2.1.1.9
Configures the processing of control signals (CA/TA) for the HSSI interface. This variable is valid only for the HSSI interface on the USSI card.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ignore(1), process(2)  

hssiDteLoopback 1.3.6.1.4.1.3174.2.7.2.1.1.10
Configures the local DTE for loopback operation: TRUE : request local DTE to go into line loopback FALSE : request local DTE to abandon line loopback These commands are valid only if the HSSI adaptor is in DCE mode and connected to a local DTE. Since the local DTE has a greater loopback priority than the local DCE, a loopback request initiated by the DCE will be ignored if the DTE simultaneously requests the DCE to loopback. Similarly, the DTE will abort a loopback already initiated by the DCE when the DTE requests the DCE to loopback.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hssiDceLoopbackTest 1.3.6.1.4.1.3174.2.7.2.1.1.11
Configures the local/remote DCE for loopback operation. Three DCE loopback modes are available: line, cable, and remote. Use noTest to abandon any of the DCE loopbacks. If the DCE is already in any one of the loopback modes, then noTest must be issued to abort the current test before initiating another loopback request. These commands are valid only if the HSSI adaptor is in DTE mode and it connected to a DCE.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noTest(1), line(2), cable(3), remote(4)  

hssiStatsTable 1.3.6.1.4.1.3174.2.7.2.3
The HSSI interface status parameters are listed in this table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HssiStatsTableEntry

hssiStatsTableEntry 1.3.6.1.4.1.3174.2.7.2.3.1
HSSI Statistics table entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  HssiStatsTableEntry  

hssiStatsAlarmStatus 1.3.6.1.4.1.3174.2.7.2.3.1.1
Specifies the status of the HSSI alarm. If the particular bit is set, then it indicates that the alarm is in ON state. Alarm bits are mode dependent; they are interpreted as follows: hssi-alarms-CA - CA not received from DCE (HSSI is DTE) hssi-alarms-ST - HSSI adaptor driving ST (HSSI is DCE) hssi-alarms-TM - TM received from DCE (HSSI is DTE) hssi-alarms-LC - HSSI adaptor detects LC (HSSI is DTE) hssi-alarms-LC - HSSI adaptor driving LC (HSSI is DCE) hssi-alarms-TA - TA not received from DTE (HSSI is DCE) hssi-alarms-LALB - HSSI adaptor detects LA and/or LB (HSSI is DCE) hssi-alarms-LALB - HSSI adaptor driving LA and/or LB (HSSI is DTE)
Status: current Access: read-only
OBJECT-TYPE    
  BITS hssi-no-alarms(0), hssi-alarms-CA(1), hssi-alarms-ST(2), hssi-alarms-TM(3), hssi-alarms-LC(4), hssi-alarms-TA(5), hssi-alarms-LALB(6)  

hssiStatsFramesIn 1.3.6.1.4.1.3174.2.7.2.3.1.2
Specifies the number of incoming frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hssiStatsFramesOut 1.3.6.1.4.1.3174.2.7.2.3.1.3
Specifies the number of outgoing frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hssiStatsOctetsIn 1.3.6.1.4.1.3174.2.7.2.3.1.4
Specifies the number of incoming octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hssiStatsOctetsOut 1.3.6.1.4.1.3174.2.7.2.3.1.5
Specifies the number of outgoing octets.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hssiStatsCRCErrors 1.3.6.1.4.1.3174.2.7.2.3.1.6
Specifies the number of CRC errors that have been identified.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

hssiTraps 1.3.6.1.4.1.3174.2.7.2.2
OBJECT IDENTIFIER    

hssiTrapVariables 1.3.6.1.4.1.3174.2.7.2.2.1
OBJECT IDENTIFIER    

hssiAlarmType 1.3.6.1.4.1.3174.2.7.2.2.1.1
Specifies the type of alarm generated by the agent for the HSSI interface. Alarms are mode dependent; they are interpreted as follows: hssi-alarms-CA - CA not received from DCE (HSSI is DTE) hssi-alarms-ST - HSSI adaptor driving ST (HSSI is DCE) hssi-alarms-TM - TM received from DCE (HSSI is DTE) hssi-alarms-LC - HSSI adaptor detects LC (HSSI is DTE) hssi-alarms-LC - HSSI adaptor driving LC (HSSI is DCE) hssi-alarms-TA - TA not received from DTE (HSSI is DCE) hssi-alarms-LALB - HSSI adaptor detects LA and/or LB (HSSI is DCE) hssi-alarms-LALB - HSSI adaptor driving LA and/or LB (HSSI is DTE)
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER hssi-alarm-CA(1), hssi-alarm-ST(2), hssi-alarm-TM(3), hssi-alarm-LC(4), hssi-alarm-TA(5), hssi-alarm-LALB(6)  

hssiAlarmOnTrap 1
HSSI alarm traps for the Alarm-On state.
TRAP-TYPE    

hssiAlarmOffTrap 2
HSSI alarm traps for the Alarm-Off state.
TRAP-TYPE