T3610-MIB
File:
T3610-MIB.mib (12938 bytes)
Imported modules
Imported symbols
Defined Types
HistoryEntry |
|
SEQUENCE |
|
|
|
|
histTemp |
INTEGER |
|
|
histHum |
INTEGER |
|
|
histCompVal |
INTEGER |
|
Defined Values
comet |
1.3.6.1.4.1.22626 |
OBJECT IDENTIFIER |
|
|
|
products |
1.3.6.1.4.1.22626.1 |
OBJECT IDENTIFIER |
|
|
|
t3610 |
1.3.6.1.4.1.22626.1.2 |
OBJECT IDENTIFIER |
|
|
|
values |
1.3.6.1.4.1.22626.1.2.1 |
OBJECT IDENTIFIER |
|
|
|
global |
1.3.6.1.4.1.22626.1.2.2 |
OBJECT IDENTIFIER |
|
|
|
valuesInt |
1.3.6.1.4.1.22626.1.2.3 |
OBJECT IDENTIFIER |
|
|
|
settings |
1.3.6.1.4.1.22626.1.2.4 |
OBJECT IDENTIFIER |
|
|
|
traps |
1.3.6.1.4.1.22626.1.2.5 |
OBJECT IDENTIFIER |
|
|
|
tables |
1.3.6.1.4.1.22626.1.2.6 |
OBJECT IDENTIFIER |
|
|
|
temp |
1.3.6.1.4.1.22626.1.2.1.1 |
Temperature |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
hum |
1.3.6.1.4.1.22626.1.2.1.2 |
Relative humidity |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
compVal |
1.3.6.1.4.1.22626.1.2.1.3 |
Computed value |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
tempAlarm |
1.3.6.1.4.1.22626.1.2.1.5 |
Alarm on Temperature; none, high, low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
humAlarm |
1.3.6.1.4.1.22626.1.2.1.6 |
Alarm on Relative humidity; none, high, low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
compValAlarm |
1.3.6.1.4.1.22626.1.2.1.7 |
Alarm on Computed value; none, high, low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
tempUnit |
1.3.6.1.4.1.22626.1.2.1.9 |
Temperature Unit |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
humUnit |
1.3.6.1.4.1.22626.1.2.1.10 |
Relative humidity Unit |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
compValUnit |
1.3.6.1.4.1.22626.1.2.1.11 |
Computed value Unit |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
tempMin |
1.3.6.1.4.1.22626.1.2.1.13 |
Minimal temperature |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
humMin |
1.3.6.1.4.1.22626.1.2.1.14 |
Minimal relative humidity |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
compValMin |
1.3.6.1.4.1.22626.1.2.1.15 |
Minimal computed value |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
tempMax |
1.3.6.1.4.1.22626.1.2.1.17 |
Maximal temperature |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
humMax |
1.3.6.1.4.1.22626.1.2.1.18 |
Maximal relative humidity |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
compValMax |
1.3.6.1.4.1.22626.1.2.1.19 |
Maximal computed value |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
sensorName |
1.3.6.1.4.1.22626.1.2.2.1 |
Device name |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..68) |
|
serialNumber |
1.3.6.1.4.1.22626.1.2.2.2 |
Serial number |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
deviceType |
1.3.6.1.4.1.22626.1.2.2.3 |
Device type |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65534 |
|
tempInt |
1.3.6.1.4.1.22626.1.2.3.1 |
Temperature (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
humInt |
1.3.6.1.4.1.22626.1.2.3.2 |
Relative humidity (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
compValInt |
1.3.6.1.4.1.22626.1.2.3.3 |
Computed value (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
tempAlarmInt |
1.3.6.1.4.1.22626.1.2.3.5 |
Alarm on Temperature; 0 - No, 1 - High, 2 - Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
humAlarmInt |
1.3.6.1.4.1.22626.1.2.3.6 |
Alarm on Relative humidity; 0 - No, 1 - High, 2 - Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
compValAlarmInt |
1.3.6.1.4.1.22626.1.2.3.7 |
Alarm on Computed value; 0 - No, 1 - High, 2 - Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2 |
|
tempLowInt |
1.3.6.1.4.1.22626.1.2.4.1 |
Temperature Limit Low (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
tempHighInt |
1.3.6.1.4.1.22626.1.2.4.2 |
Temperature Limit High (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
humLowInt |
1.3.6.1.4.1.22626.1.2.4.3 |
Humidity Limit Low (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
humHighInt |
1.3.6.1.4.1.22626.1.2.4.4 |
Humidity Limit High (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
compValLowInt |
1.3.6.1.4.1.22626.1.2.4.5 |
Computed value Limit Low (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
compValHighInt |
1.3.6.1.4.1.22626.1.2.4.6 |
Computed value Limit High (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
tempDelayInt |
1.3.6.1.4.1.22626.1.2.4.7 |
Temperature alaram delay [sec] |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4500 |
|
humDelayInt |
1.3.6.1.4.1.22626.1.2.4.8 |
Humidity alaram delay [sec] |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4500 |
|
compValDelayInt |
1.3.6.1.4.1.22626.1.2.4.9 |
Computed value alaram delay [sec] |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..4500 |
|
tempHystInt |
1.3.6.1.4.1.22626.1.2.4.10 |
Temperature hysteresis (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..10000 |
|
humHystInt |
1.3.6.1.4.1.22626.1.2.4.11 |
Humidity hysteresis (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..10000 |
|
compValHystInt |
1.3.6.1.4.1.22626.1.2.4.12 |
Computed value hysteresis (value*10) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..10000 |
|
messageString |
1.3.6.1.4.1.22626.1.2.5.1 |
Message giving more detailed information on alarms |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..32) |
|
historyTable |
1.3.6.1.4.1.22626.1.2.6.1 |
Table of the history values |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
HistoryEntry |
|
historyEntry |
1.3.6.1.4.1.22626.1.2.6.1.1 |
History values entries |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
HistoryEntry |
|
|
histTemp |
1.3.6.1.4.1.22626.1.2.6.1.1.1 |
Temperature reading |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
histHum |
1.3.6.1.4.1.22626.1.2.6.1.1.2 |
Humidity reading |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
histCompVal |
1.3.6.1.4.1.22626.1.2.6.1.1.3 |
Computed value reading |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
-5000..20000 |
|
trapTest |
0 |
Testing trap, testing trap by TSensor software |
TRAP-TYPE |
|
|
|
trapNTPError |
1 |
Error on time synchronisation via NTP |
TRAP-TYPE |
|
|
|
trapEmailErrSome |
4 |
SMTP error - error during communication with server, unexpected return code |
TRAP-TYPE |
|
|
|
trapHumError |
42 |
Trap for error on relative humidity |
TRAP-TYPE |
|
|
|