STN-ATM-MIB

File: STN-ATM-MIB.mib (102733 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IF-MIB SPRING-TIDE-NETWORKS-TC SPRING-TIDE-NETWORKS-SMI
STN-ROUTER-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 Counter32 IpAddress
TEXTUAL-CONVENTION DisplayString TruthValue
MODULE-COMPLIANCE InterfaceIndex NSAPAddress
stnSystems stnNotification stnRouterIndex

Defined Types

VcLinkOperStatus  
Operational status of a VC Link.
TEXTUAL-CONVENTION    
  INTEGER active(1), not-in-service(2), not-ready(3), create-and-go(4), create-and-wait(5), destroy(6)  

VcCrossConnOperStatus  
Operational status of a VC cross connection.
TEXTUAL-CONVENTION    
  INTEGER active(1), not-in-service(2), not-ready(3), create-and-go(4), create-and-wait(5), destroy(6)  

TrafficDescrOperStatus  
Operational status of a traffic descriptor.
TEXTUAL-CONVENTION    
  INTEGER active(1), not-in-service(2), not-ready(3), create-and-go(4), create-and-wait(5), destroy(6)  

AtmPortOperStatus  
Operational status of an ATM port.
TEXTUAL-CONVENTION    
  INTEGER active(1), inactive(2)  

StnVcLinkEntry  
SEQUENCE    
  stnVcLinkIfIndex InterfaceIndex
  stnVcLinkVpi Integer32
  stnVcLinkVci Integer32
  stnVcLinkRcvTrafDescr Integer32
  stnVcLinkXmtTrafDescr Integer32
  stnVcLinkAalObjectsValid Integer32
  stnVcLinkAalType INTEGER
  stnVcLinkAal5XmtSDUSize Integer32
  stnVcLinkAal5RcvSDUSize Integer32
  stnVcLinkAal5EncapsType Integer32
  stnVcLinkCastType INTEGER
  stnVcLinkConnKind INTEGER
  stnVcLinkAccEnabled TruthValue
  stnVcLinkOAMMgmtEnabled TruthValue
  stnVcLinkOAMXmtFrequency Integer32
  stnVcLinkOAMRetryUpCount Integer32
  stnVcLinkOAMRetryDownCount Integer32
  stnVcLinkOAMRetryFrequency Integer32
  stnVcLinkPppId Integer32
  stnVcLinkOperStatus VcLinkOperStatus

StnVcCrossConnEntry  
SEQUENCE    
  stnVcCrossConnLowIfIndex InterfaceIndex
  stnVcCrossConnLowVpi Integer32
  stnVcCrossConnLowVci Integer32
  stnVcCrossConnHighIfIndex InterfaceIndex
  stnVcCrossConnHighVpi Integer32
  stnVcCrossConnHighVci Integer32
  stnVcCrossConnLowAutoAssign TruthValue
  stnVcCrossConnHighAutoAssign TruthValue
  stnVcCrossConnOperStatus VcCrossConnOperStatus

StnTrafficDescrEntry  
SEQUENCE    
  stnTrafDescrIndex Integer32
  stnTrafDescrName OCTET STRING
  stnTrafDescrType INTEGER
  stnTrafDescrParam1 Integer32
  stnTrafDescrParam2 Integer32
  stnTrafDescrParam3 Integer32
  stnTrafDescrParam4 Integer32
  stnTrafDescrParam5 Integer32
  stnTrafDescrQosClass INTEGER
  stnTrafDescrServiceCategory INTEGER
  stnTrafDescrFrameDiscard TruthValue
  stnTrafDescrOperStatus TrafficDescrOperStatus
  stnTrafDescrCommittedRate Integer32
  stnTrafDescrMaximumRate Integer32

StnAtmPortAttrEntry  
SEQUENCE    
  stnAtmPortIfIndex InterfaceIndex
  stnAtmPortIfType Integer32
  stnAtmPortIfState INTEGER
  stnAtmPortEnabled TruthValue
  stnAtmPortMinVccVpi INTEGER
  stnAtmPortMaxVccVpi INTEGER
  stnAtmPortMinVccVci INTEGER
  stnAtmPortMaxVccVci INTEGER
  stnAtmPortMinVpcVpi INTEGER
  stnAtmPortMaxVpcVpi INTEGER
  stnAtmPortMaxActivePaths INTEGER
  stnAtmPortMaxActiveChannels INTEGER
  stnAtmPortPVCAddress NSAPAddress
  stnAtmPortSVCAddress NSAPAddress
  stnAtmPortSigVpi Integer32
  stnAtmPortSigVci Integer32
  stnAtmPortSigEnabled TruthValue
  stnAtmPortIlmiVpi Integer32
  stnAtmPortIlmiVci Integer32
  stnAtmPortIlmiEnabled TruthValue
  stnAtmPortOamManagementEnabled TruthValue
  stnAtmPortOamXmtFrequency Integer32
  stnAtmPortOamRetryUpCount Integer32
  stnAtmPortOamRetryDownCount Integer32
  stnAtmPortOamRetryFrequency Integer32
  stnAtmPortOperStatus AtmPortOperStatus

StnAtmPortIlmiEntry  
SEQUENCE    
  stnAtmPortIlmiIfIndex InterfaceIndex
  stnAtmPortIlmiVersion INTEGER
  stnAtmPortIlmiNetworkOrientation INTEGER
  stnAtmPortIlmiAutoNegotiate TruthValue
  stnAtmPortIlmiPollInterval Integer32
  stnAtmPortIlmiCheckConnectionInt Integer32
  stnAtmPortIlmiInactivityFactor Integer32
  stnAtmPortIlmiLocalConn INTEGER
  stnAtmPortIlmiAdminStatus BITS
  stnAtmPortIlmiEnterprise OBJECT IDENTIFIER
  stnAtmPortIlmiLocalOid OBJECT IDENTIFIER
  stnAtmPortIlmiNetPrefix OCTET STRING
  stnAtmPortIlmiPrefixLen Integer32

StnAtmPortSigEntry  
SEQUENCE    
  stnAtmPortSigIfIndex InterfaceIndex
  stnAtmPortSigVersion INTEGER
  stnAtmPortSigNetworkOrientation INTEGER
  stnAtmPortSigAssignVpiVci TruthValue
  stnAtmPortSigVpSigType INTEGER
  stnAtmPortSigParseMode INTEGER
  stnAtmPortSigPrefCarrierPresent TruthValue
  stnAtmPortSigPrefCarrier TruthValue

StnAtmPortSigDurationEntry  
SEQUENCE    
  stnAtmPortSigDurIfIndex InterfaceIndex
  stnAtmPortSigT301Duration Integer32
  stnAtmPortSigT303Duration Integer32
  stnAtmPortSigT306Duration Integer32
  stnAtmPortSigT308Duration Integer32
  stnAtmPortSigT309Duration Integer32
  stnAtmPortSigT310Duration Integer32
  stnAtmPortSigT313Duration Integer32
  stnAtmPortSigT316Duration Integer32
  stnAtmPortSigT317Duration Integer32
  stnAtmPortSigT322Duration Integer32
  stnAtmPortSigT331Duration Integer32
  stnAtmPortSigT333Duration Integer32
  stnAtmPortSigT397Duration Integer32
  stnAtmPortSigT398Duration Integer32
  stnAtmPortSigT399Duration Integer32
  stnAtmPortSigSaalRetryDuration Integer32

StnAtmPortSigRetryEntry  
SEQUENCE    
  stnAtmPortSigRetryIfIndex InterfaceIndex
  stnAtmPortSigT303Retries Integer32
  stnAtmPortSigT308Retries Integer32
  stnAtmPortSigT316Retries Integer32
  stnAtmPortSigT322Retries Integer32
  stnAtmPortSigT331Retries Integer32

StnAtmPortSigSSCSEntry  
SEQUENCE    
  stnAtmPortSigSSCSIfIndex InterfaceIndex
  stnAtmPortSigSSCSPollDuration Integer32
  stnAtmPortSigSSCSKeepAliveDuration Integer32
  stnAtmPortSigSSCSIdleDuration Integer32
  stnAtmPortSigSSCSNoRspDuration Integer32
  stnAtmPortSigSSCSCcDuration Integer32
  stnAtmPortSigSSCSMaxRcvWindowSize Integer32
  stnAtmPortSigSSCSMaxCcRetries Integer32
  stnAtmPortSigSSCSMaxSdBetwPolls Integer32
  stnAtmPortSigSSCSMaxStatListElms Integer32
  stnAtmPortSigSSCSPollAfterRetrans TruthValue
  stnAtmPortSigSSCSRepeatUstat TruthValue
  stnAtmPortSigSSCSUstatRspToPoll TruthValue

StnAtmPortTrafficEntry  
SEQUENCE    
  stnAtmPortTrafIndex InterfaceIndex
  stnAtmPortTrafTxCells Counter32
  stnAtmPortTrafRxCells Counter32
  stnAtmPortTrafTxParityErrors Counter32
  stnAtmPortTrafRxHdrChkSumErrors Counter32
  stnAtmPortTrafPhyParityErrors Counter32
  stnAtmPortTrafCrc10Errors Counter32

StnAtmAddressEntry  
SEQUENCE    
  stnAtmAddrIfIndex InterfaceIndex
  stnAtmAddrAddress NSAPAddress
  stnAtmAddrAddressLen Integer32

StnAtmThresholdEntry  
SEQUENCE    
  stnAtmTholdTgrpId INTEGER
  stnAtmTholdRegionId INTEGER
  stnAtmTholdCellLowerLimit INTEGER
  stnAtmTholdCellUpperLimit INTEGER
  stnAtmTholdCellQLimitMarking INTEGER
  stnAtmTholdQLimitDiscard INTEGER
  stnAtmTholdQueueLimit INTEGER

Defined Values

stnAtm 3.1.3551.2.6
Initial version of this MIB module.
MODULE-IDENTITY    

stnAtmObjects 3.1.3551.2.6.1
OBJECT IDENTIFIER    

stnAtmMibConformance 3.1.3551.2.6.2
OBJECT IDENTIFIER    


stnAtmCrossConns 3.1.3551.2.6.1.2
OBJECT IDENTIFIER    

stnAtmTrafficDescrs 3.1.3551.2.6.1.3
OBJECT IDENTIFIER    

stnAtmPorts 3.1.3551.2.6.1.4
OBJECT IDENTIFIER    

stnAtmTraces 3.1.3551.2.6.1.5
OBJECT IDENTIFIER    

stnAtmQos 3.1.3551.2.6.1.6
OBJECT IDENTIFIER    

stnAtmAddresses 3.1.3551.2.6.1.7
OBJECT IDENTIFIER    

stnAtmThresholds 3.1.3551.2.6.1.8
OBJECT IDENTIFIER    

stnAtmAcct 3.1.3551.2.6.1.9
OBJECT IDENTIFIER    


stnVcCrossConns 3.1.3551.2.6.1.2.1
OBJECT IDENTIFIER    

stnVpCrossConns 3.1.3551.2.6.1.2.2
OBJECT IDENTIFIER    

stnAtmPortAttrs 3.1.3551.2.6.1.4.1
OBJECT IDENTIFIER    

stnAtmPortIlmi 3.1.3551.2.6.1.4.2
OBJECT IDENTIFIER    

stnAtmPortSignaling 3.1.3551.2.6.1.4.3
OBJECT IDENTIFIER    

stnAtmPortTraffic 3.1.3551.2.6.1.4.4
OBJECT IDENTIFIER    

stnTraceIps 3.1.3551.2.6.1.5.1
OBJECT IDENTIFIER    

stnTracePd 3.1.3551.2.6.1.5.2
OBJECT IDENTIFIER    

stnQosCLR 3.1.3551.2.6.1.6.1
OBJECT IDENTIFIER    

stnQosCDV 3.1.3551.2.6.1.6.2
OBJECT IDENTIFIER    

stnQosCTD 3.1.3551.2.6.1.6.3
OBJECT IDENTIFIER    

stnAtmPortSigs 3.1.3551.2.6.1.4.3.1
OBJECT IDENTIFIER    

stnAtmPortSigDurations 3.1.3551.2.6.1.4.3.2
OBJECT IDENTIFIER    

stnAtmPortSigRetries 3.1.3551.2.6.1.4.3.3
OBJECT IDENTIFIER    

stnVcLinkTable 3.1.3551.2.6.1.1.1.1
A list of VC Link entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnVcLinkEntry

stnVcLinkEntry 3.1.3551.2.6.1.1.1.1.1
Entry contains information about a particular VC link.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnVcLinkEntry  

stnVcLinkIfIndex 3.1.3551.2.6.1.1.1.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnVcLinkVpi 3.1.3551.2.6.1.1.1.1.1.2
The VPI value of the VPL. Note that the VPI=0 is not used for a VPL not associated with a VCL. The maximum VPI value cannot exceed the value allowable by the atmInterfaceMaxVpiBits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkVci 3.1.3551.2.6.1.1.1.1.1.3
The VCI value of the VCL. The maximum VCI value cannot exceed the value allowable by the atmInterfaceMaxVciBits.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkRcvTrafDescr 3.1.3551.2.6.1.1.1.1.1.4
Receive traffic descriptor identifier for this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkXmtTrafDescr 3.1.3551.2.6.1.1.1.1.1.5
Transmit traffic descriptor identifier for this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkAalObjectsValid 3.1.3551.2.6.1.1.1.1.1.6
Indicates whether the following AAL objects are valid (whether the local VCL end-point is also the VCC end-point). Transmit traffic descriptor identifier for this VPL.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkAalType 3.1.3551.2.6.1.1.1.1.1.7
An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL is in use. The type of AAL used on this VCC. The AAL type includes AAL1, AAL3/4, and AAL5. The other(4) may be used as a user-defined AAL type. The unknown type indicates that the AAL type cannot be determined.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER aal1(1), aal3-4(2), aal5(3), other(4)  

stnVcLinkAal5XmtSDUSize 3.1.3551.2.6.1.1.1.1.1.8
An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The maximum AAL5 CPCS SDUsize in octets that is supported on the transmit direction of this VCC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkAal5RcvSDUSize 3.1.3551.2.6.1.1.1.1.1.9
An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The maximum AAL5 CPCS SDU size in octets that is supported on the receive direction of this VCC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkAal5EncapsType 3.1.3551.2.6.1.1.1.1.1.10
An instance of this object only exists when the local VCL end-point is also the VCC end-point, and AAL5 is in use. The type of data encapsulation used over the AAL5 SSCS layer. The definitions reference RFC 1483 Multiprotocol Encapsulation over ATM AAL5 and to the ATM Forum LAN Emulation specification.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkCastType 3.1.3551.2.6.1.1.1.1.1.11
The type of topology of a connection (point- to-point, point-to-multipoint). In the case of point-to-multipoint, the orientation of this VPL in the connection. On a host, p2mpRoot indicates that the host is the root of the p2mp connection, p2mpLeaf indicates that the host is a leaf of the p2mp connection. On a switch, p2mpRoot indicates that cells received by the switching fabric from the interface are from the root of the p2mp connection, p2mpLeaf indicates that cells transmitted to the interface from the switching fabric are to the leaf of the p2mp connection.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER p2mpRoot(1), p2mpLeaf(2)  

stnVcLinkConnKind 3.1.3551.2.6.1.1.1.1.1.12
The use of call control. An spvcInitiator is always cross-connected to an svcOutgoing, and an spvcTarget is always cross-connected to an svcIncoming.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER pvc(1), svc-incomming(2), svc-outgoing(3), spvc-initiator(4), spvc-target(5)  

stnVcLinkAccEnabled 3.1.3551.2.6.1.1.1.1.1.13
ATM accounting is enabled for this VC Link.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnVcLinkOAMMgmtEnabled 3.1.3551.2.6.1.1.1.1.1.14
OAM management is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnVcLinkOAMXmtFrequency 3.1.3551.2.6.1.1.1.1.1.15
Number of seconds between transmitting OAM loopback cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkOAMRetryUpCount 3.1.3551.2.6.1.1.1.1.1.16
Number of consecutive end-to-end F5 OAM loopback cell responses that must be received in order to change a PVC state to up. Does not apply to SVCs.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkOAMRetryDownCount 3.1.3551.2.6.1.1.1.1.1.17
Number of consecutive end-to-end F5 OAM loopback cell responses that are not received in order to change a PVC state to down or tear down an SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkOAMRetryFrequency 3.1.3551.2.6.1.1.1.1.1.18
The frequency (in seconds) that end-to-end F5 loopback cells should be transmitted when a change in UP/DOWN state is being verified. For example, if a PVC is up and a loopback cell response is not received after the frequency (in seconds, then loopback cells are sent at the retry-frequency to verify whether or not the PVC is down.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkPppId 3.1.3551.2.6.1.1.1.1.1.19
PPP ID
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcLinkOperStatus 3.1.3551.2.6.1.1.1.1.1.20
Operational status of the VC Link.
Status: current Access: read-only
OBJECT-TYPE    
  VcLinkOperStatus  

stnVcCrossConnTable 3.1.3551.2.6.1.2.1.1
A list of VC cross connection entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnVcCrossConnEntry

stnVcCrossConnEntry 3.1.3551.2.6.1.2.1.1.1
Entry contains information about a particular VC cross connection.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnVcCrossConnEntry  

stnVcCrossConnLowIfIndex 3.1.3551.2.6.1.2.1.1.1.1
The value of this object is equal to MIB II's ifIndex value of the ATM interface port for this VP cross-connect. The term low implies that this ATM interface has the numerically lower ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnVcCrossConnLowVpi 3.1.3551.2.6.1.2.1.1.1.2
The value of this object is equal to the VPI value at the ATM interface associated with the VP cross-connect that is identified by LowIfIndex. The VPI value cannot exceed the number supported by the atmInterfaceMaxVpiBits at the low ATM interface port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcCrossConnLowVci 3.1.3551.2.6.1.2.1.1.1.3
The value of this object is equal to the VCI value at the ATM interface associated with the VC cross-connect that is identified by LowIfIndex. The VCI value cannot exceed the number supported by the atmInterfaceMaxVciBits at the low ATM interface port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcCrossConnHighIfIndex 3.1.3551.2.6.1.2.1.1.1.4
The value of this object is equal to MIB II's ifIndex value of the ATM interface port for this VP cross-connect. The term low implies that this ATM interface has the numerically lower ifIndex.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnVcCrossConnHighVpi 3.1.3551.2.6.1.2.1.1.1.5
The value of this object is equal to the VPI value at the ATM interface associated with the VP cross-connect that is identified by LowIfIndex. The VPI value cannot exceed the number supported by the atmInterfaceMaxVpiBits at the low ATM interface port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcCrossConnHighVci 3.1.3551.2.6.1.2.1.1.1.6
The value of this object is equal to the VCI value at the ATM interface associated with the VC cross-connect that is identified by LowIfIndex. The VCI value cannot exceed the number supported by the atmInterfaceMaxVciBits at the low ATM interface port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnVcCrossConnLowAutoAssign 3.1.3551.2.6.1.2.1.1.1.7
Controls low vpi/vci/ifIndex auto assignement to an ECF. If set to true MSM will attempt to dynamically auto assign the connection to an available ECF.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnVcCrossConnHighAutoAssign 3.1.3551.2.6.1.2.1.1.1.8
Controls high vpi/vci/ifIndex auto assignement to an ECF. If set to true MSM will attempt to dynamically auto assign the connection to an available ECF.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnVcCrossConnOperStatus 3.1.3551.2.6.1.2.1.1.1.9
Operational status of the VC cross connection.
Status: current Access: read-only
OBJECT-TYPE    
  VcCrossConnOperStatus  

stnTrafficDescrTable 3.1.3551.2.6.1.3.1
A list of ATM traffic descriptor entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnTrafficDescrEntry

stnTrafficDescrEntry 3.1.3551.2.6.1.3.1.1
Entry contains information about a particular ATM traffic descriptor.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnTrafficDescrEntry  

stnTrafDescrIndex 3.1.3551.2.6.1.3.1.1.1
The value of this object identifies the row in the stnTrafficDescrTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrName 3.1.3551.2.6.1.3.1.1.2
Text name assigned to this traffic descriptor.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

stnTrafDescrType 3.1.3551.2.6.1.3.1.1.3
The value of this object identifies the type of ATM traffic descriptor. The type may indicate no traffic descriptor or traffic descriptor with one or more parameters. These parameters are specified as a parameter vector, in the corresponding instances of the objects: atmTrafDescrParam1, atmTrafDescrParam2, atmTrafDescrParam3, atmTrafDescrParam4, atmTrafDescrParam5 Type values are as follows: no-td no-clp-no-scr clp-no-ag-no-scr clp-agging-no-scr no-clp-scr clp-no-tag-scr clp-tagging-scr clp-no-tag-mcr clp-trans-no-scr clp-trans-scr no-clp-tag-no-scr
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER no-td(1), no-clp-no-scr(2), clp-no-tag-no-scr(3), clp-tagging-no-scr(4), no-clp-scr(5), clp-no-tag-scr(6), clp-tagging-scr(7), clp-no-tag-mcr(8), clp-trans-no-scr(9), clp-trans-scr(10), no-clp-tag-no-scr(11)  

stnTrafDescrParam1 3.1.3551.2.6.1.3.1.1.4
The first parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrParam2 3.1.3551.2.6.1.3.1.1.5
The second parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrParam3 3.1.3551.2.6.1.3.1.1.6
The third parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrParam4 3.1.3551.2.6.1.3.1.1.7
The fourth parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrParam5 3.1.3551.2.6.1.3.1.1.8
The fifth parameter of the ATM traffic descriptor used according to the value of atmTrafDescrType.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrQosClass 3.1.3551.2.6.1.3.1.1.9
The value of this object identifies the QoS Class. Four Service classes have been specified in the ATM Forum UNI Specification: Service Class A: Constant bit rate video and Circuit emulation. Service Class B: Variable bit rate video/audio. Service Class C: Connection-oriented data. Service Class D: Connectionless data. Four QoS classes numbered 1, 2, 3, and 4 have been specified with the aim to support service classes A, B, C, and D respectively. An unspecified QoS Class numbered '0' is used for best effort traffic.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER best-effort(0), service-class-a(1), service-class-b(2), service-class-c(3), service-class-d(4)  

stnTrafDescrServiceCategory 3.1.3551.2.6.1.3.1.1.10
The ATM service category. Service categories are as follows: other, cbr, rt-vbr, nrt-vbr, abr, ubr
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), cbr(2), rt-vbr(3), nrt-vbr(4), abr(5), ubr(6)  

stnTrafDescrFrameDiscard 3.1.3551.2.6.1.3.1.1.11
Whether the network should discard frames rather than cells.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTrafDescrOperStatus 3.1.3551.2.6.1.3.1.1.12
Operational status of the traffic descriptor.
Status: current Access: read-only
OBJECT-TYPE    
  TrafficDescrOperStatus  

stnTrafDescrCommittedRate 3.1.3551.2.6.1.3.1.1.13
The traffic rate in bits per second that the network is committed to transmit for VCs using this transmit traffic descriptor.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTrafDescrMaximumRate 3.1.3551.2.6.1.3.1.1.14
The maximum traffic rate in bits per second that the network will transmit for VCs using this transmit traffic descriptor, if it differs from the committed rate.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTraceIpsEnabled 3.1.3551.2.6.1.5.1.1
Specifies whether IPS tracing is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTraceIpsSize 3.1.3551.2.6.1.5.1.2
Specifies the maximum IPS trace buffer size multipled by 1024. The IPS trace log file will wrap when it reaches the maximum. Default: 1000 x 1024 Lines
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTraceIpsFile 3.1.3551.2.6.1.5.1.3
Specifies the IPS output path and file name. Changes to the path or filename take effect when IPS tracing is disabled and restarted (close file and open new).
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

stnTracePdProblemEnabled 3.1.3551.2.6.1.5.2.1
Specifies whether PD problem tracing is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTracePdExceptionEnabled 3.1.3551.2.6.1.5.2.2
Specifies whether PD exception tracing is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTracePdAuditEnabled 3.1.3551.2.6.1.5.2.3
Specifies whether PD audit tracing is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTracePdDeveloperEnabled 3.1.3551.2.6.1.5.2.4
Specifies whether PD developer tracing is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnTracePdSize 3.1.3551.2.6.1.5.2.5
Specifies the maximum PD trace buffer size multipled by 1024. The PD trace log file will wrap when it reaches the maximum.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnTracePdFile 3.1.3551.2.6.1.5.2.6
Specifies the IPS output path and file name. Changes to the path or filename take effect when IPS tracing is disabled and restarted.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

stnQosClass1CLR 3.1.3551.2.6.1.6.1.1
QoS Class 1 cell loss ratio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass2CLR 3.1.3551.2.6.1.6.1.2
QoS Class 2 cell loss ratio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass3CLR 3.1.3551.2.6.1.6.1.3
QoS Class 3 cell loss ratio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass4CLR 3.1.3551.2.6.1.6.1.4
QoS Class 4 cell loss ratio.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass1CDV 3.1.3551.2.6.1.6.2.1
QoS Class 1 cell delay variation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass2CDV 3.1.3551.2.6.1.6.2.2
QoS Class 2 cell delay variation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass3CDV 3.1.3551.2.6.1.6.2.3
QoS Class 3 cell delay variation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass4CDV 3.1.3551.2.6.1.6.2.4
QoS Class 4 cell delay variation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass1MaxCTD 3.1.3551.2.6.1.6.3.1
QoS Class 1 cell transfer delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass2MaxCTD 3.1.3551.2.6.1.6.3.2
QoS Class 2 cell transfer delay.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass3MaxCTD 3.1.3551.2.6.1.6.3.3
QoS Class 3 cell delay transfer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnQosClass4MaxCTD 3.1.3551.2.6.1.6.3.4
QoS Class 4 cell delay transfer.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortAttrTable 3.1.3551.2.6.1.4.1.1
A list of ATM port attribute entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortAttrEntry

stnAtmPortAttrEntry 3.1.3551.2.6.1.4.1.1.1
Entry contains information about a particular ATM port attribute entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortAttrEntry  

stnAtmPortIfIndex 3.1.3551.2.6.1.4.1.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortIfType 3.1.3551.2.6.1.4.1.1.1.2
The interface type of the connection point to the switch fabric. Values are: sonet(1), enet(2), epif(3), rim-enet(4).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIfState 3.1.3551.2.6.1.4.1.1.1.3
The interface state of the connection point to the switch fabric. Values are: not-present(0), detected(1), configured(2), up-non-redundant(3), up-redundant(4), down-non-redundant(5), down-redundant(6), failed(7), initialized(8)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..8  

stnAtmPortEnabled 3.1.3551.2.6.1.4.1.1.1.4
Whether the ATM port is enabled.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortMinVccVpi 3.1.3551.2.6.1.4.1.1.1.5
Minimum VPI used for Virtual Channel Circuits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

stnAtmPortMaxVccVpi 3.1.3551.2.6.1.4.1.1.1.6
Maximum VPI used for Virtual Channel Circuits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

stnAtmPortMinVccVci 3.1.3551.2.6.1.4.1.1.1.7
Minimum VCI used for Virtual Channel Circuits. To avoid clashes with the reserved ATM VCI values (such as 5 for signaling and any other reserved values including Connection Manager VCs), the recommended value is 32.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..65554  

stnAtmPortMaxVccVci 3.1.3551.2.6.1.4.1.1.1.8
Maximum VCI used for Virtual Channel Circuits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..65554  

stnAtmPortMinVpcVpi 3.1.3551.2.6.1.4.1.1.1.9
Minimum VPI used for Virtual Path Circuits. To avoid clashes with the reserved ATM VCCs values (such as 5 for signaling and any other reserved values including Connection Manager VCs), the recommended value is 1.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

stnAtmPortMaxVpcVpi 3.1.3551.2.6.1.4.1.1.1.10
Maximum VCI used for Virtual Channel Circuits.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

stnAtmPortMaxActivePaths 3.1.3551.2.6.1.4.1.1.1.11
The maximum number of active paths that can be active at any time on this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

stnAtmPortMaxActiveChannels 3.1.3551.2.6.1.4.1.1.1.12
The maximum number of virtual channels that can be active at any time on this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65554  

stnAtmPortPVCAddress 3.1.3551.2.6.1.4.1.1.1.13
The default configured PVC address information (20-byte NSAP address).
Status: current Access: read-only
OBJECT-TYPE    
  NSAPAddress  

stnAtmPortSVCAddress 3.1.3551.2.6.1.4.1.1.1.14
The default configured SVC address information (20-byte NSAP address).
Status: current Access: read-only
OBJECT-TYPE    
  NSAPAddress  

stnAtmPortSigVpi 3.1.3551.2.6.1.4.1.1.1.15
The VPI used for the signaling channel.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigVci 3.1.3551.2.6.1.4.1.1.1.16
The VCI used for the signaling channel.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigEnabled 3.1.3551.2.6.1.4.1.1.1.17
Indicates if port will have a signaling stack.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortIlmiVpi 3.1.3551.2.6.1.4.1.1.1.18
The VPI used for ILMI channel.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIlmiVci 3.1.3551.2.6.1.4.1.1.1.19
The VCI used for ILMI channel.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIlmiEnabled 3.1.3551.2.6.1.4.1.1.1.20
Indicates if port will use ILMI.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortOamManagementEnabled 3.1.3551.2.6.1.4.1.1.1.21
Indicates if port is using OAM Management Procedures.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortOamXmtFrequency 3.1.3551.2.6.1.4.1.1.1.22
Indicates Frequency of OAM Transmit Cells.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortOamRetryUpCount 3.1.3551.2.6.1.4.1.1.1.23
Indicates OAM Cell Retry Up Count value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortOamRetryDownCount 3.1.3551.2.6.1.4.1.1.1.24
Indicates OAM Cell Retry Down Count value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortOamRetryFrequency 3.1.3551.2.6.1.4.1.1.1.25
Indicates OAM Retry Frequency value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortOperStatus 3.1.3551.2.6.1.4.1.1.1.26
Operational status of the Port.
Status: current Access: read-only
OBJECT-TYPE    
  AtmPortOperStatus  

stnAtmPortIlmiTable 3.1.3551.2.6.1.4.2.1
A list of ATM ILMI Port entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortIlmiEntry

stnAtmPortIlmiEntry 3.1.3551.2.6.1.4.2.1.1
Entry contains information about a particular ATM Port ILMI entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortIlmiEntry  

stnAtmPortIlmiIfIndex 3.1.3551.2.6.1.4.2.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortIlmiVersion 3.1.3551.2.6.1.4.2.1.1.2
Specifies the signaling stack protocol type to be used on this port. Valid options are: uni-3-dot-0 uni-3-dot-1 uni-4-dot-0 iisp-3-dot-1
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uni-3-dot-0(1), uni-3-dot-1(2), uni-4-dot-0(3), iisp-3-dot-1(4)  

stnAtmPortIlmiNetworkOrientation 3.1.3551.2.6.1.4.2.1.1.3
Specifies the ATM device type. Valid options are: user, network
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER user(1), network(2)  

stnAtmPortIlmiAutoNegotiate 3.1.3551.2.6.1.4.2.1.1.4
Indicates ILMI auto negotiation mode
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortIlmiPollInterval 3.1.3551.2.6.1.4.2.1.1.5
ILMI connection poll interval (S) in seconds. When DC-ILMI is transmitting SNMP Get messages during the attempt to establish connectivity with the remote ILMI component, this parameter determines the time in seconds between transmissions. The default value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIlmiCheckConnectionInt 3.1.3551.2.6.1.4.2.1.1.6
ILMI check connection poll interval (T) in seconds. If connectivity checking is enabled (as spec by the value connect in the Admin_Status parameter below), this parameter specifies the time in seconds between successive transmissions of MIB Get msgs for the purpose of detecting loss of ILMI connectivity. If connectivity checking is not enabled, this parameter must be set to zero. The default value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIlmiInactivityFactor 3.1.3551.2.6.1.4.2.1.1.7
ILMI inactivity factor (K). The number of consecutive polls for which no response is received from the remote ILMI component before ILMI connectivity is assumed to be lost. The dflt value is from the ATM Forum ILMI Specification Version 4.0: ILMI Connectivity Procedures (section 8.3.1).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortIlmiLocalConn 3.1.3551.2.6.1.4.2.1.1.8
Specifies whether the local end of the ILMI connection is advertised as a 'public' or 'private' ILMI device. Values are: other, public, private
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), public(2), private(3)  

stnAtmPortIlmiAdminStatus 3.1.3551.2.6.1.4.2.1.1.9
Specifies which functions of DC-ILMI are enabled. The value std-ilmi must be specified; this value may be combined (using a bitwise OR) with one or more of the following values: std-ilmi - Standard ILMI functions are enabled. addr-reg - Address registration is enabled. connect - Connectivity chcking is enabled (DC-ILMI periodically sends a MIB Get request for the remote system's System ID, to ensure that it can still send and rcvd data on the ILMI connection). Default: (std-ilmi | addr-reg | connect)
Status: current Access: read-only
OBJECT-TYPE    
  BITS std-ilmi(0), addr-reg(1), connect(2)  

stnAtmPortIlmiEnterprise 3.1.3551.2.6.1.4.2.1.1.10
Enterprise Object ID that DC-ILMI will use in building SNMP traps (or other generic MIB traps). This parameter can be used to identify the originator of the trap. The Object ID is specified as an array of unsigned long vals, as follows: The first entry in the array is the length of the array (the num of unsigned long values it contains, including the len value). The second entry in the array is an identifier specifying the Family type of the Object ID. This reps a prefix Object ID; the MIB Sub-Agent is responsible for matching this id with the dotted-decimal notation for this prefix. The remainder of the array gives the index part of the Object ID (the dotted-decimal notation from the end of the Family), with 1 unsigned long for each decimal number in this notation.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

stnAtmPortIlmiLocalOid 3.1.3551.2.6.1.4.2.1.1.11
Object ID identifying the local machine - the first 4 octets indicate the length of the object id. For example, the null object id (0.0), which should be used if no object id is specified, is encoded as 3, 0, 0.
Status: current Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

stnAtmPortIlmiNetPrefix 3.1.3551.2.6.1.4.2.1.1.12
Default network prefix. If the prefix length is non-zero, ILMI creates an entry in the ILMI NetPrefix Table for this prefix; otherwise the Net_Prefix parameter is not used.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..13)  

stnAtmPortIlmiPrefixLen 3.1.3551.2.6.1.4.2.1.1.13
The length of the default network prefix
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigTable 3.1.3551.2.6.1.4.3.1.1
A list of ATM port signal entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortSigEntry

stnAtmPortSigEntry 3.1.3551.2.6.1.4.3.1.1.1
Entry contains information about a particular ATM port signal entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortSigEntry  

stnAtmPortSigIfIndex 3.1.3551.2.6.1.4.3.1.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortSigVersion 3.1.3551.2.6.1.4.3.1.1.1.2
Specifies the signaling stack protocol type to be used on this port. Valid options are: UNI 3.0, UNI 3.1, IISP 3.1, PNNI 1.0
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER uni-3-dot-0(1), uni-3-dot-1(2), iisp-3-dot-1(3), pnni-1-dot-0(4)  

stnAtmPortSigNetworkOrientation 3.1.3551.2.6.1.4.3.1.1.1.3
Indicates whether the ATM device is of the user or network type. Valid values are: user, network
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER user(1), network(2)  

stnAtmPortSigAssignVpiVci 3.1.3551.2.6.1.4.3.1.1.1.4
Specifies whether VPI/VCI assignment is the responsibility of the local signaling stack or of its partner stack. This parameter is used only for UNI 4.0. Values are: true - The local signaling stack is responsible for assigning VPIs/VCIs. false - The parent-signaling stack is responsible for assigning VPIs/VCIs.
Status: current Access: not-accessible
OBJECT-TYPE    
  TruthValue  

stnAtmPortSigVpSigType 3.1.3551.2.6.1.4.3.1.1.1.5
Specifies whether this signaling stack performs VP associated signaling: Valid options are: associated-signaling explicit-vpci
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER associated-signaling(1), explicit-vpci(2)  

stnAtmPortSigParseMode 3.1.3551.2.6.1.4.3.1.1.1.6
Specifies whether the message parser component of Sig should perform validity checking on the contents of received IEs. This element resides in the CCS MIB to allow software config of this behavior for compliance testing. Values are: normal - The parser checks the contents of the IEs the Sig uses and ensures that they are valid. For other IEs, it checks only the IE type and length and does not parse the contents. strict - The parser checks the contents of addit IEs as well as those used by Signaling and also checks for incorrect repetition of these add it IEs. Errors are handled in the same way as for the IEs used by sig (by sending a status message in UNI 3.1 or by following the IE instruction indicator in UNI 4.0).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), strict(2)  

stnAtmPortSigPrefCarrierPresent 3.1.3551.2.6.1.4.3.1.1.1.7
Specifies whether a default prefrd carrier (transit network) is defined. Valid options are: true - the Default_Network_Id below defines which carr is the preferred carrier. false - no default preferred carrier is defined.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortSigPrefCarrier 3.1.3551.2.6.1.4.3.1.1.1.8
Specifies the default preferred carrier. If stnAtmPortIlmiPrefCarrierPresent is set to false, this element is not used.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortSigDurationTable 3.1.3551.2.6.1.4.3.2.1
A list of ATM Port Signaling Duration entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortSigDurationEntry

stnAtmPortSigDurationEntry 3.1.3551.2.6.1.4.3.2.1.1
Entry contains information about a particular ATM Port Signaling Duration entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortSigDurationEntry  

stnAtmPortSigDurIfIndex 3.1.3551.2.6.1.4.3.2.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortSigT301Duration 3.1.3551.2.6.1.4.3.2.1.1.2
T301 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT303Duration 3.1.3551.2.6.1.4.3.2.1.1.3
T303 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT306Duration 3.1.3551.2.6.1.4.3.2.1.1.4
T306 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT308Duration 3.1.3551.2.6.1.4.3.2.1.1.5
T308 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Intrface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT309Duration 3.1.3551.2.6.1.4.3.2.1.1.6
T309 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT310Duration 3.1.3551.2.6.1.4.3.2.1.1.7
T310 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT313Duration 3.1.3551.2.6.1.4.3.2.1.1.8
T313 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT316Duration 3.1.3551.2.6.1.4.3.2.1.1.9
T316 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT317Duration 3.1.3551.2.6.1.4.3.2.1.1.10
T317 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT322Duration 3.1.3551.2.6.1.4.3.2.1.1.11
T322 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT331Duration 3.1.3551.2.6.1.4.3.2.1.1.12
T331 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT333Duration 3.1.3551.2.6.1.4.3.2.1.1.13
T333 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT397Duration 3.1.3551.2.6.1.4.3.2.1.1.14
T397 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT398Duration 3.1.3551.2.6.1.4.3.2.1.1.15
T398 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT399Duration 3.1.3551.2.6.1.4.3.2.1.1.16
T399 timer. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSaalRetryDuration 3.1.3551.2.6.1.4.3.2.1.1.17
SAAL retry duration. See ITU-T Q.2931 B-ISDN DSS2 User-Network Interface (UNI) Layer 3 Specification for Basic Call/Connection Control
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigRetryTable 3.1.3551.2.6.1.4.3.3.1
A list of ATM Port Signaling retry entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortSigRetryEntry

stnAtmPortSigRetryEntry 3.1.3551.2.6.1.4.3.3.1.1
Entry contains information about a ITU-T Q.2931 timer retry counters.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortSigRetryEntry  

stnAtmPortSigRetryIfIndex 3.1.3551.2.6.1.4.3.3.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortSigT303Retries 3.1.3551.2.6.1.4.3.3.1.1.2
The number of ATM Port Signaling T303 retries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT308Retries 3.1.3551.2.6.1.4.3.3.1.1.3
The number of ATM Port Signaling T308 retries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT316Retries 3.1.3551.2.6.1.4.3.3.1.1.4
The number of ATM Port Signaling T316 retries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT322Retries 3.1.3551.2.6.1.4.3.3.1.1.5
The number of ATM Port Signaling T322 retries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigT331Retries 3.1.3551.2.6.1.4.3.3.1.1.6
The number of ATM Port Signaling T331 retries.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSTable 3.1.3551.2.6.1.4.3.3.2
A list of ATM Port Signaling SSCS entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortSigSSCSEntry

stnAtmPortSigSSCSEntry 3.1.3551.2.6.1.4.3.3.2.1
Entry contains information about a particular Atm Port Signaling SSCS entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortSigSSCSEntry  

stnAtmPortSigSSCSIfIndex 3.1.3551.2.6.1.4.3.3.2.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortSigSSCSPollDuration 3.1.3551.2.6.1.4.3.3.2.1.2
The duration of the SSCS Poll timer in milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSKeepAliveDuration 3.1.3551.2.6.1.4.3.3.2.1.3
The duration of the SSCS keep-alive timer in milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSIdleDuration 3.1.3551.2.6.1.4.3.3.2.1.4
The duration of the SSCS idle timer in milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSNoRspDuration 3.1.3551.2.6.1.4.3.3.2.1.5
The duration of the SSCS no-response timer in milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSCcDuration 3.1.3551.2.6.1.4.3.3.2.1.6
The duration of the SSCS CC timer in milliseconds.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSMaxRcvWindowSize 3.1.3551.2.6.1.4.3.3.2.1.7
The maximum size on a receive window.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSMaxCcRetries 3.1.3551.2.6.1.4.3.3.2.1.8
The maximum number of expiries and subsequent connection control PDU retransmissions acceptable before closing the connection.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSMaxSdBetwPolls 3.1.3551.2.6.1.4.3.3.2.1.9
The maximum number of STAT list elements in a STAT PDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSMaxStatListElms 3.1.3551.2.6.1.4.3.3.2.1.10
The maximum number of STAT list elements in a STAT PDU.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmPortSigSSCSPollAfterRetrans 3.1.3551.2.6.1.4.3.3.2.1.11
Whether to send a POLL after retransmitting PDUs.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortSigSSCSRepeatUstat 3.1.3551.2.6.1.4.3.3.2.1.12
QSAAL only: if true, send two USTATs each time a USTAT is sent.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortSigSSCSUstatRspToPoll 3.1.3551.2.6.1.4.3.3.2.1.13
QSAAL only: whether USTAT PDUs are issued in response to POLLs.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmPortTrafficTable 3.1.3551.2.6.1.4.4.1
A list of ATM port traffic entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmPortTrafficEntry

stnAtmPortTrafficEntry 3.1.3551.2.6.1.4.4.1.1
Entry contains information about a particular ATM port traffic entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmPortTrafficEntry  

stnAtmPortTrafIndex 3.1.3551.2.6.1.4.4.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmPortTrafTxCells 3.1.3551.2.6.1.4.4.1.1.2
The number of ATM cells transmitted.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmPortTrafRxCells 3.1.3551.2.6.1.4.4.1.1.3
The number of ATM cells received.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmPortTrafTxParityErrors 3.1.3551.2.6.1.4.4.1.1.4
The number of ATM transmit parity errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmPortTrafRxHdrChkSumErrors 3.1.3551.2.6.1.4.4.1.1.5
The number of received ATM header checksum errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmPortTrafPhyParityErrors 3.1.3551.2.6.1.4.4.1.1.6
The number of ATM physical parity errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmPortTrafCrc10Errors 3.1.3551.2.6.1.4.4.1.1.7
The number of ATM CRC-10 errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

stnAtmAddressTable 3.1.3551.2.6.1.7.1
A list of ATM address entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmAddressEntry

stnAtmAddressEntry 3.1.3551.2.6.1.7.1.1
Entry contains information about a particular session.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmAddressEntry  

stnAtmAddrIfIndex 3.1.3551.2.6.1.7.1.1.1
The interface index represents a connection point on the switch fabric from a module or line card. It is calculated based on the slot and port of the module.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

stnAtmAddrAddress 3.1.3551.2.6.1.7.1.1.2
The value of the ATM NSAP address.
Status: current Access: read-only
OBJECT-TYPE    
  NSAPAddress  

stnAtmAddrAddressLen 3.1.3551.2.6.1.7.1.1.3
The number of relevent bits in the ATM address.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmThresholdTable 3.1.3551.2.6.1.8.1
A list of ATM threshold entries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    StnAtmThresholdEntry

stnAtmThresholdEntry 3.1.3551.2.6.1.8.1.1
Entry contains information about a particular ATM threshold entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  StnAtmThresholdEntry  

stnAtmTholdTgrpId 3.1.3551.2.6.1.8.1.1.1
Specifies the threshold group indentifier.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

stnAtmTholdRegionId 3.1.3551.2.6.1.8.1.1.2
Region identifier within a threshold group.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..7  

stnAtmTholdCellLowerLimit 3.1.3551.2.6.1.8.1.1.3
Lower Cell number limit for region.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

stnAtmTholdCellUpperLimit 3.1.3551.2.6.1.8.1.1.4
Upper Cell number limit for region.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

stnAtmTholdCellQLimitMarking 3.1.3551.2.6.1.8.1.1.5
Queue limit for any flow above which EFCI marking occurs.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

stnAtmTholdQLimitDiscard 3.1.3551.2.6.1.8.1.1.6
Queue limit for any flow above which Discard processing occurs.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

stnAtmTholdQueueLimit 3.1.3551.2.6.1.8.1.1.7
Queue limit for any flow above which cells are automatically discarded.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

stnAtmAcctEnabled 3.1.3551.2.6.1.9.1
Specifies whether account logging is turned on or off.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

stnAtmAcctMaxSize 3.1.3551.2.6.1.9.2
Specifies the maximum accounting log buffer size. in Kbytes. The accounting log file will be closed when it reaches the maximum size and the name appended with a numeric differentiation.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmAcctMaxFiles 3.1.3551.2.6.1.9.3
Specifies the maximum number of history files to be stored. Once the maximum number of files is reached, the oldest file is deleted.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stnAtmAcctFilePath 3.1.3551.2.6.1.9.4
Specifies the accounting log output path and file name on remote device.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

stnAtmAcctFtpServer1 3.1.3551.2.6.1.9.5
The IP address of the first remote FTP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

stnAtmAcctFtpUserName1 3.1.3551.2.6.1.9.6
The first FTP server username.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

stnAtmAcctFtpPassword1 3.1.3551.2.6.1.9.7
The first FTP server password.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

stnAtmAcctFtpServer2 3.1.3551.2.6.1.9.8
The IP address of the second remote FTP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

stnAtmAcctFtpUserName2 3.1.3551.2.6.1.9.9
The second FTP server username.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

stnAtmAcctFtpPassword2 3.1.3551.2.6.1.9.10
The second FTP server password.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

stnAtmAcctFtpServer3 3.1.3551.2.6.1.9.11
The IP address of the third remote FTP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

stnAtmAcctFtpUserName3 3.1.3551.2.6.1.9.12
The third FTP server username.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

stnAtmAcctFtpPassword3 3.1.3551.2.6.1.9.13
The third FTP server password.
Status: current Access: not-accessible
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

stnAtmAcctCurrentFtpServer 3.1.3551.2.6.1.9.14
The IP address of the current FTP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

stnAtmAcctPreviousFtpServer 3.1.3551.2.6.1.9.15
The IP address of the previous FTP server.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

stnCdrServerFailure 3.1.3551.2.100.0.15
A stnCdrServerFailure trap signifies that the agent entity has detected that the accounting server has failed over to an auxilary server. The generation of this trap can be controlled by the stnNotificationEnableCdrServerFailure object in this MIB.
Status: current Access: read-only
NOTIFICATION-TYPE    

stnCdrLogFailure 3.1.3551.2.100.0.16
A stnCdrLogFailure trap signifies that the agent entity has detected that all accounting servers are inaccessible. Accounting data could be lost. The generation of this trap can be controlled by the stnNotificationEnableCdrLogFailure object in this MIB.
Status: current Access: read-only
NOTIFICATION-TYPE    

stnConfigAuditPvcFailure 3.1.3551.2.100.0.31
A stnConfigAuditPvcFailure trap signifies that the agent entity has detected an inconsistency between an active and configured PVC after a failover. The generation of this trap can be controlled by the CfgAuditPvcTraps configuration object.
Status: current Access: read-only
NOTIFICATION-TYPE    

stnConfigAuditSpvcFailure 3.1.3551.2.100.0.32
A stnConfigAuditSpvcFailure trap signifies that the agent entity has detected an inconsistency between an active and configured SPVC after a failover. The generation of this trap can be controlled by the CfgAuditSpvcTraps configuration object.
Status: current Access: read-only
NOTIFICATION-TYPE