SSPM-MIB

File: SSPM-MIB.mib (35387 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
RMON-MIB INET-ADDRESS-MIB IF-MIB
APM-MIB SYSAPPL-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 Unsigned32 TEXTUAL-CONVENTION
StorageType TruthValue RowStatus
MODULE-COMPLIANCE OBJECT-GROUP OwnerString
rmon InetAddressType InetAddress
InterfaceIndexOrZero AppLocalIndex Utf8String

Defined Types

SspmMicroSeconds  
A unit of time with resolution of MicroSeconds.
TEXTUAL-CONVENTION    
  Unsigned32  

SspmClockSource  
An indication of the source of the clock as defined by the NTP specification RFC1305 [RFC1305] definition of stratum: Stratum (sys.stratum, peer.stratum, pkt.stratum): This is an integer indicating the stratum of the local clock, with values defined as follows: 0 unspecified 1 primary reference (e.g., calibrated atomic clock, radio clock) 2-255 secondary reference (via NTP).
TEXTUAL-CONVENTION    
  Integer32 0..255  

SspmClockMaxSkew  
An indication of the accuracy of the clock as defined by RFC1305. This variable indicates the maximum offset error due to skew of the local clock over the time interval 86400 seconds, in seconds.
TEXTUAL-CONVENTION    
  Integer32 1..65535  

SspmCapabilitiesEntry  
SEQUENCE    
  sspmCapabilitiesInstance AppLocalIndex

SspmSourceProfileEntry  
SEQUENCE    
  sspmSourceProfileInstance Unsigned32
  sspmSourceProfileType AppLocalIndex
  sspmSourceProfilePacketSize Unsigned32
  sspmSourceProfilePacketFillType INTEGER
  sspmSourceProfilePacketFillValue OCTET STRING
  sspmSourceProfileTOS Integer32
  sspmSourceProfileFlowLabel Integer32
  sspmSourceProfileLooseSrcRteFill OCTET STRING
  sspmSourceProfileLooseSrcRteLen Integer32
  sspmSourceProfileTTL Integer32
  sspmSourceProfileNoFrag TruthValue
  sspmSourceProfile8021Tagging Integer32
  sspmSourceProfileUsername Utf8String
  sspmSourceProfilePassword Utf8String
  sspmSourceProfileParameter OCTET STRING
  sspmSourceProfileOwner OwnerString
  sspmSourceProfileStorageType StorageType
  sspmSourceProfileStatus RowStatus

SspmSourceControlEntry  
SEQUENCE    
  sspmSourceControlInstance Unsigned32
  sspmSourceControlProfile Integer32
  sspmSourceControlSrc InterfaceIndexOrZero
  sspmSourceControlDestAddrType InetAddressType
  sspmSourceControlDestAddr InetAddress
  sspmSourceControlEnabled TruthValue
  sspmSourceControlTimeOut SspmMicroSeconds
  sspmSourceControlSamplingDist INTEGER
  sspmSourceControlFrequency SspmMicroSeconds
  sspmSourceControlFirstSeqNum Unsigned32
  sspmSourceControlLastSeqNum Unsigned32
  sspmSourceControlOwner OwnerString
  sspmSourceControlStorageType StorageType
  sspmSourceControlStatus RowStatus

SspmSinkEntry  
SEQUENCE    
  sspmSinkInstance Unsigned32
  sspmSinkType AppLocalIndex
  sspmSinkSourceAddressType InetAddressType
  sspmSinkSourceAddress InetAddress
  sspmSinkExpectedRate SspmMicroSeconds
  sspmSinkEnable TruthValue
  sspmSinkExpectedFirstSequenceNum Unsigned32
  sspmSinkLastSequenceNumber Unsigned32
  sspmSinkLastSequenceInvalid Counter32
  sspmSinkStorageType StorageType
  sspmSinkStatus RowStatus

Defined Values

sspmMIB 1.3.6.1.2.1.16.28
This SSPM MIB module is applicable to probes implementing Synthetic Source for Performance Monitoring functions. Copyright (C) The Internet Society (2005). This version of this MIB module is part of RFC 4149; see the RFC itself for full legal notices.
MODULE-IDENTITY    

sspmMIBObjects 1.3.6.1.2.1.16.28.1
OBJECT IDENTIFIER    

sspmMIBNotifications 1.3.6.1.2.1.16.28.2
OBJECT IDENTIFIER    

sspmMIBConformance 1.3.6.1.2.1.16.28.3
OBJECT IDENTIFIER    

sspmGeneral 1.3.6.1.2.1.16.28.1.1
OBJECT IDENTIFIER    

sspmGeneralClockResolution 1.3.6.1.2.1.16.28.1.1.1
A read-only variable indicating the resolution of the measurements possible by this device.
Status: current Access: read-only
OBJECT-TYPE    
  SspmMicroSeconds  

sspmGeneralClockMaxSkew 1.3.6.1.2.1.16.28.1.1.2
A read-only variable indicating the maximum offset error due to skew of the local clock over the time interval 86400 seconds, in seconds.
Status: current Access: read-only
OBJECT-TYPE    
  SspmClockMaxSkew  

sspmGeneralClockSource 1.3.6.1.2.1.16.28.1.1.3
A read-only variable indicating the source of the clock. This is provided to allow a user to determine how accurate the timing mechanism is compared with other devices. This is needed for the coordination of time values between probes for one-way measurements.
Status: current Access: read-only
OBJECT-TYPE    
  SspmClockSource  

sspmGeneralMinFrequency 1.3.6.1.2.1.16.28.1.1.4
A read-only variable that indicates the devices' capability for the minimum supported sspmSourceFrequency. If sspmSourceFrequency is set to a value lower than the value reported by this attribute, then the set of sspmSourceFrequency will fail with an inconsistent value error.
Status: current Access: read-only
OBJECT-TYPE    
  SspmMicroSeconds  

sspmCapabilitiesTable 1.3.6.1.2.1.16.28.1.1.5
The table of SSPM capabilities.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SspmCapabilitiesEntry

sspmCapabilitiesEntry 1.3.6.1.2.1.16.28.1.1.5.1
Details about a particular SSPM capability.
Status: current Access: not-accessible
OBJECT-TYPE    
  SspmCapabilitiesEntry  

sspmCapabilitiesInstance 1.3.6.1.2.1.16.28.1.1.5.1.1
Indicates whether SSPM configuration of the corresponding AppLocalIndex is supported by this device. Generally, entries in this table are only made by the device when the configuration of the measurement is available.
Status: current Access: read-only
OBJECT-TYPE    
  AppLocalIndex  

sspmSource 1.3.6.1.2.1.16.28.1.2
OBJECT IDENTIFIER    

sspmSourceProfileTable 1.3.6.1.2.1.16.28.1.2.1
The table of SSPM Source Profiles configured.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SspmSourceProfileEntry

sspmSourceProfileEntry 1.3.6.1.2.1.16.28.1.2.1.1
Details about a particular SSPM Source Profile configuration. Entries must exist in this table in order to be referenced by rows in the sspmSourceControlTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  SspmSourceProfileEntry  

sspmSourceProfileInstance 1.3.6.1.2.1.16.28.1.2.1.1.1
An arbitrary index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sspmSourceProfileType 1.3.6.1.2.1.16.28.1.2.1.1.2
The AppLocalIndex value that uniquely identifies the measurement per the APM-MIB. In order to create a row in this table, there must be a corresponding row in the sspmCapabilitiesTable. When attempting to set this object, if no corresponding row exists in the sspmCapabilitiesTable, then the agent should return a 'badValue' error.
Status: current Access: read-create
OBJECT-TYPE    
  AppLocalIndex  

sspmSourceProfilePacketSize 1.3.6.1.2.1.16.28.1.2.1.1.3
The size of packet to be transmitted in bytes. The size accounts for all data within the IPv4 or IPv6 payloads, excluding the IP headers, IP header options and link-level protocol headers. If the size is set smaller than the minimum allowed packet size or greater than the maximum allowed packet size, then the set should fail, and the agent should return a 'badValue' error.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

sspmSourceProfilePacketFillType 1.3.6.1.2.1.16.28.1.2.1.1.4
Indicates how the packet is filled. 'random' indicates that the packet contains random data patterns. This is probe and implementation dependent. 'pattern' indicates that the pattern defined in the sspmSourceProfilePacketFillValue attribute is used to fill the packet. 'url' indicates that the value of sspmSourceProfilePacketFillValue should contain a URL. The contents of the document at that URL are retrieved when sspmSourceStatus becomes active and utilized in the packet. If the attempt to access that URL fails, then the row status is set to 'notReady', and the set should fail with 'inconsistentValue'. This value must contain a dereferencable URL of the type 'http:', 'https:', or 'ftp:' only.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER random(1), pattern(2), url(3)  

sspmSourceProfilePacketFillValue 1.3.6.1.2.1.16.28.1.2.1.1.5
The string value with which to fill the packet. If sspmSourceProfilePacketFillType is set to 'pattern', then this pattern is repeated until the packet is sspmSourcePacketSize in bytes. Note that if the length of the octet string specified for this value does not divide evenly into the packet size, then an incomplete last copy of this data may be copied into the packet. If the value of sspmSourceProfilePacketFillType is set to 'random', then this attribute is unused. If the value of the sspmSourceProfilePacketFillType is set to 'url', then the URL specified in this attribute is retrieved and used by the probe. In the case of a URL, this value must contain a dereferencable URL of the type 'http:', 'https:', or 'ftp:' only.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..255)  

sspmSourceProfileTOS 1.3.6.1.2.1.16.28.1.2.1.1.6
Represents the TOS field in the IP packet header. The value of this object defaults to zero if not set.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..255  

sspmSourceProfileFlowLabel 1.3.6.1.2.1.16.28.1.2.1.1.7
This object is used to specify the Flow Label in a IPv6 packet (RFC 2460) to force special handling by the IPv6 routers; e.g., non-default quality-of-service handling. This object is meaningful only when the object sspmSourceDestAddressType is IPv6(2). The value of this object defaults to zero if not set.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..1048575  

sspmSourceProfileLooseSrcRteFill 1.3.6.1.2.1.16.28.1.2.1.1.8
In the event that the test should run over a specific route, the intent is to force the route using the Loose Source Route option in IPv4 [RFC791] and IPv6 [RFC2460]. This object contains a series of IP addresses along the path that would be put into the loose source route option in the IP header. The IPv4 addresses are to be listed as 32-bit address values, and the IPv6 addresses are to be listed as a string of 128-bit addresses. The maximum length allowed within the IPv4 source route option is 63 addresses. To simply account for IPv6 addresses as well, the maximum length of the octet string is 240. This allows up to 60 IPv4 addresses or up to 15 IPv6 addresses in the string.
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..240)  

sspmSourceProfileLooseSrcRteLen 1.3.6.1.2.1.16.28.1.2.1.1.9
In the event that the test should run over a specific route, the intent is to force the route. This attribute specifies the length of data to be copied from the sspmSourceProfileLooseSrcRteFill into the route data fields of the loose source route options in the IPv4 or IPv6 headers.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..240  

sspmSourceProfileTTL 1.3.6.1.2.1.16.28.1.2.1.1.10
If non-zero, this specifies the value to place into the TTL field on transmission.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..255  

sspmSourceProfileNoFrag 1.3.6.1.2.1.16.28.1.2.1.1.11
When true, the 'Don't Fragment Bit' should be set on the packet header.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

sspmSourceProfile8021Tagging 1.3.6.1.2.1.16.28.1.2.1.1.12
IEEE 802.1Q tagging used in IEEE 802.1D bridged environments. A value of -1 indicates that the packets are untagged. A value of 0 to 65535 is the value of the tag to be inserted in the tagged packets. Note that according to IEEE 802.1Q, VLAN-ID tags with a value of 4095 shall not be transmitted on the wire. As the VLAN-ID is encoded in the 12 least significant bits on the tag, values that translate in a binary representation of all 1's in the last 12 bits SHALL NOT be configured. In this case, the set should fail, and return an error-status of 'inconsistentValue'.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 -1..65535  

sspmSourceProfileUsername 1.3.6.1.2.1.16.28.1.2.1.1.13
An optional username used by the application protocol.
Status: current Access: read-create
OBJECT-TYPE    
  Utf8String  

sspmSourceProfilePassword 1.3.6.1.2.1.16.28.1.2.1.1.14
An optional password used by the application protocol.
Status: current Access: read-create
OBJECT-TYPE    
  Utf8String  

sspmSourceProfileParameter 1.3.6.1.2.1.16.28.1.2.1.1.15
An optional parameter used by the application protocol. For DNS, this would be the hostname or IP. For HTTP, this would be the URL. For nntp, this would be the news group. For TCP, this would be the port number. For SMTP, this would be the recipient (and could assume the message is predefined).
Status: current Access: read-create
OBJECT-TYPE    
  OCTET STRING Size(0..65535)  

sspmSourceProfileOwner 1.3.6.1.2.1.16.28.1.2.1.1.16
Name of the management station/application that set up the profile.
Status: current Access: read-create
OBJECT-TYPE    
  OwnerString  

sspmSourceProfileStorageType 1.3.6.1.2.1.16.28.1.2.1.1.17
The storage type of this sspmSourceProfileEntry. If the value of this object is 'permanent', no objects in this row need to be writable.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

sspmSourceProfileStatus 1.3.6.1.2.1.16.28.1.2.1.1.18
Status of this profile. An entry may not exist in the active state unless all objects in the entry have an appropriate value. Once this object is set to active(1), no objects in the sspmSourceProfileTable can be changed.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sspmSourceControlTable 1.3.6.1.2.1.16.28.1.2.2
The table of SSPM measurements configured.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SspmSourceControlEntry

sspmSourceControlEntry 1.3.6.1.2.1.16.28.1.2.2.1
Details about a particular SSPM configuration.
Status: current Access: not-accessible
OBJECT-TYPE    
  SspmSourceControlEntry  

sspmSourceControlInstance 1.3.6.1.2.1.16.28.1.2.2.1.1
An arbitrary index.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sspmSourceControlProfile 1.3.6.1.2.1.16.28.1.2.2.1.2
A pointer to the profile (sspmSourceProfileEntry) that this control entry uses to define the test being performed.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 1..65535  

sspmSourceControlSrc 1.3.6.1.2.1.16.28.1.2.2.1.3
The ifIndex where the packet should originate from the probe (if it matters). A value of zero indicates that it does not matter and that the device decides.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

sspmSourceControlDestAddrType 1.3.6.1.2.1.16.28.1.2.2.1.4
The type of Internet address by which the destination is accessed.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddressType  

sspmSourceControlDestAddr 1.3.6.1.2.1.16.28.1.2.2.1.5
The Internet address for the destination. The formatting of this object is controlled by the sspmSourceControlDestAddrType object above. When this object contains a DNS name, then the name is resolved to an address each time measurement is to be made. Further, the agent should not cache this address, but instead should perform the resolution prior to each measurement.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

sspmSourceControlEnabled 1.3.6.1.2.1.16.28.1.2.2.1.6
When set to 'true', this test is enabled. When set to 'false', it is disabled.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

sspmSourceControlTimeOut 1.3.6.1.2.1.16.28.1.2.2.1.7
Timeout value for the measurement response. If no response is received in the time specified, then the test fails.
Status: current Access: read-create
OBJECT-TYPE    
  SspmMicroSeconds  

sspmSourceControlSamplingDist 1.3.6.1.2.1.16.28.1.2.2.1.8
When this attribute is set to 'deterministic', then packets are generated at with a fixed inter-packet injection time specified by sspmSourceFrequency. When this attribute is set to 'Poisson', then packets are generated with inter-packet injection times sampled from an exponential distribution with the single distributional parameter determined by the inverse frequency).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER deterministic(1), poisson(2)  

sspmSourceControlFrequency 1.3.6.1.2.1.16.28.1.2.2.1.9
The inverse of this value is the rate at which packets are generated. Refer to sspmSourceSamplingDistribution. If the value set is less than the value of sspmGeneralMinFrequency, then the set will fail with an error-status of 'inconsistentValue'.
Status: current Access: read-create
OBJECT-TYPE    
  SspmMicroSeconds  

sspmSourceControlFirstSeqNum 1.3.6.1.2.1.16.28.1.2.2.1.10
The first sequence number of packets to be transmitted.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

sspmSourceControlLastSeqNum 1.3.6.1.2.1.16.28.1.2.2.1.11
The last sequence number transmitted. This value is updated by the agent after packet generation.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sspmSourceControlOwner 1.3.6.1.2.1.16.28.1.2.2.1.12
Name of the management station/application that set up the test.
Status: current Access: read-create
OBJECT-TYPE    
  OwnerString  

sspmSourceControlStorageType 1.3.6.1.2.1.16.28.1.2.2.1.13
The storage type of this sspmSourceControlEntry. If the value of this object is 'permanent', no objects in this row need to be writable.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

sspmSourceControlStatus 1.3.6.1.2.1.16.28.1.2.2.1.14
Status of this source control entry. An entry may not exist in the active state unless all objects in the entry have an appropriate value. When this attribute has the value of 'active', none of the read-write or read-create attributes in this table may be modified, with the exception of sspmSourceControlEnabled.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sspmSink 1.3.6.1.2.1.16.28.1.5
OBJECT IDENTIFIER    

sspmSinkTable 1.3.6.1.2.1.16.28.1.5.1
A table configuring the sink for measurements.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SspmSinkEntry

sspmSinkEntry 1.3.6.1.2.1.16.28.1.5.1.1
The details of a particular sink entry. If the measurement is a round-trip type, then the sink entry will be on the same probe as the corresponding sspmSourceEntry. If the measurement is a one-way, type then the sink entry will be on a different probe.
Status: current Access: not-accessible
OBJECT-TYPE    
  SspmSinkEntry  

sspmSinkInstance 1.3.6.1.2.1.16.28.1.5.1.1.1
An index. When the measurement is for a round-trip measurement, then this table entry is on the same probe as the corresponding sspmSourceEntry, and the value of this attribute should correspond to the value of sspmSourceInstance. Management applications configuring sinks for one-way measurements could define some scheme whereby the sspmSinkInstance is unique across all probes. Note that the unique key to this entry is also constructed with sspmSinkType, sspmSinkSourceAddressType, and sspmSinkSourceAddress. To make the implementation simpler, those other attributes are not included in the index but uniqueness is still needed to receive all the packets.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32 1..65535  

sspmSinkType 1.3.6.1.2.1.16.28.1.5.1.1.2
The AppLocalIndex value that uniquely identifies the measurement per the APM-MIB. In order to create a row in this table, there must be a corresponding row in the sspmCapabilitiesTable. If there is no corresponding row in the sspmCapabilitiestable, then the agent will return an error-status of 'inconsistentValue'.
Status: current Access: read-create
OBJECT-TYPE    
  AppLocalIndex  

sspmSinkSourceAddressType 1.3.6.1.2.1.16.28.1.5.1.1.3
The type of Internet address of the source.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddressType  

sspmSinkSourceAddress 1.3.6.1.2.1.16.28.1.5.1.1.4
The Internet address of the source. The formatting of this object is controlled by the sspmSinkSourceAddressType object above. This object should be set only to a valid device address that has been administratively configured into the device. If a set attempts to set this object to an address that does not belong (i.e., is not administratively configured into the device), the set should fail, and the agent should return a error-status of 'inconsistentValue'.
Status: current Access: read-create
OBJECT-TYPE    
  InetAddress  

sspmSinkExpectedRate 1.3.6.1.2.1.16.28.1.5.1.1.5
The expected rate at which packets will arrive.
Status: current Access: read-create
OBJECT-TYPE    
  SspmMicroSeconds  

sspmSinkEnable 1.3.6.1.2.1.16.28.1.5.1.1.6
Indicates if the sink is enabled or not.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

sspmSinkExpectedFirstSequenceNum 1.3.6.1.2.1.16.28.1.5.1.1.7
The expected first sequence number of packets. This is used by the sink to determine if packets were lost at the initiation of the test.
Status: current Access: read-create
OBJECT-TYPE    
  Unsigned32  

sspmSinkLastSequenceNumber 1.3.6.1.2.1.16.28.1.5.1.1.8
The last sequence number received.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

sspmSinkLastSequenceInvalid 1.3.6.1.2.1.16.28.1.5.1.1.9
The number of packets that arrived whose sequence number was not one plus the value of sspmSinkLastSequenceNumber.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

sspmSinkStorageType 1.3.6.1.2.1.16.28.1.5.1.1.10
The storage type of this sspmSinkEntry. If the value of this object is 'permanent', no objects in this row need to be writable.
Status: current Access: read-create
OBJECT-TYPE    
  StorageType  

sspmSinkStatus 1.3.6.1.2.1.16.28.1.5.1.1.11
Status of this conceptual row. An entry may not exist in the active state unless all objects in the entry have an appropriate value. Once this object is set to active(1), no objects with MAX-ACCESS of read-create in the sspmSinkTable can be changed.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

sspmCompliances 1.3.6.1.2.1.16.28.3.1
OBJECT IDENTIFIER    

sspmGroups 1.3.6.1.2.1.16.28.3.2
OBJECT IDENTIFIER    

sspmGeneralCompliance 1.3.6.1.2.1.16.28.3.1.1
A general compliance that allows all things to be optional.
Status: current Access: read-create
MODULE-COMPLIANCE    

sspmSourceFullCompliance 1.3.6.1.2.1.16.28.3.1.2
A source compliance. Use this compliance when implementing a traffic-source-only device. This is useful for implementing devices that probe other devices for intrusive application monitoring. It is also useful for implementing the source of one-way tests used with a sink-only device.
Status: current Access: read-create
MODULE-COMPLIANCE    

sspmSinkFullCompliance 1.3.6.1.2.1.16.28.3.1.3
A sink-only compliance. Use this compliance when implementing a sink-only device. This is useful for devices to receive one-way measurements.
Status: current Access: read-create
MODULE-COMPLIANCE    

sspmGeneralGroup 1.3.6.1.2.1.16.28.3.2.1
The objects in the SSPM General Group.
Status: current Access: read-create
OBJECT-GROUP    

sspmSourceGroup 1.3.6.1.2.1.16.28.3.2.2
The objects in the SSPM Source Group.
Status: current Access: read-create
OBJECT-GROUP    

sspmUserPassGroup 1.3.6.1.2.1.16.28.3.2.3
The objects in the SSPM Username and password group.
Status: current Access: read-create
OBJECT-GROUP    

sspmSinkGroup 1.3.6.1.2.1.16.28.3.2.4
The objects in the SSPM Sink Group.
Status: current Access: read-create
OBJECT-GROUP