SS7I-MIB

File: SS7I-MIB.mib (21756 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

enterprises experimental IpAddress
TimeTicks Gauge Counter
DisplayString OBJECT-TYPE

Defined Types

Ss7iCfgEntry  
SEQUENCE    
  ss7iCfgIndex INTEGER
  ss7iCfgIpAddr IpAddress
  ss7iCfgNetmask IpAddress
  ss7iCfgDfltGwIpAddr IpAddress
  ss7iCfgProtocol INTEGER
  ss7iCfgGwConnStartMethod INTEGER
  ss7iCfgGwIpAddr IpAddress
  ss7iCfgGwPort INTEGER
  ss7iCfgSecGwIpAddr IpAddress
  ss7iCfgSecGwPort INTEGER
  ss7iCfgHrtbtTimerNearEnd INTEGER
  ss7iCfgHrtbtTimerFarEnd INTEGER
  ss7iCfgChassisId OCTET STRING
  ss7iCfgGwConnRetryCnt INTEGER
  ss7iCfgGwConnRetryIntvl INTEGER
  ss7iCfgGwMssdHrtbtThrsh INTEGER

Ss7iCmdEntry  
SEQUENCE    
  ss7iCmdIndex INTEGER
  ss7iCmdMgtStationId OCTET STRING
  ss7iCmdReqId INTEGER
  ss7iCmdFunction INTEGER
  ss7iCmdForce INTEGER
  ss7iCmdParam OCTET STRING
  ss7iCmdResult INTEGER
  ss7iCmdCode INTEGER

Ss7iTrapEntry  
SEQUENCE    
  ss7iTrapIndex INTEGER
  ss7iTrapPbusLinkUp INTEGER
  ss7iTrapPbusLinkDown INTEGER
  ss7iTrapGwConnUp INTEGER
  ss7iTrapGwConnDown INTEGER

Ss7iStatEntry  
SEQUENCE    
  ss7iStatIndex INTEGER
  ss7iStatGwConnStatus INTEGER
  ss7iStatGwNumMsgsRcvd Counter
  ss7iStatGwNumBytesRcvd Counter
  ss7iStatGwNumMsgsSent Counter
  ss7iStatGwNumBytesSent Counter
  ss7iStatGwMssdHrtbtCnt Counter
  ss7iStatGwLinkLostCnt Counter
  ss7iStatGwLinkErrCnt Counter
  ss7iStatGwLinkDownCause INTEGER

Ss7iHdmEntry  
SEQUENCE    
  ss7iHdmIndex INTEGER
  ss7iHdmIndex2 INTEGER
  ss7iHdmConnState INTEGER
  ss7iHdmSndPktsOkCnt Counter
  ss7iHdmSndPktsFailCnt Counter
  ss7iHdmRcvPktsOkCnt Counter
  ss7iHdmRcvPktsFailCnt Counter
  ss7iHdmLinkDownCause INTEGER

Ss7iSigPbEntry  
SEQUENCE    
  ss7iSigPbIndex INTEGER
  ss7iSigPbIndex2 INTEGER
  ss7iSigPbConnection INTEGER
  ss7iSigPbLoopback INTEGER

Defined Values

usr 1.3.6.1.4.1.429
OBJECT IDENTIFIER    

nas 1.3.6.1.4.1.429.1
OBJECT IDENTIFIER    

ss7i 1.3.6.1.4.1.429.1.35
OBJECT IDENTIFIER    

ss7iCfg 1.3.6.1.4.1.429.1.35.1
OBJECT IDENTIFIER    

ss7iCfgTable 1.3.6.1.4.1.429.1.35.1.1
The Configuration Table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current configuration of parameters that affect the operation of all the entities that reside on the given card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iCfgEntry

ss7iCfgEntry 1.3.6.1.4.1.429.1.35.1.1.1
There is one Configuration Table entry per HiPer SS7i Card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iCfgEntry  

ss7iCfgIndex 1.3.6.1.4.1.429.1.35.1.1.1.1
A unique value for each HiPer SS7i card in the chassis. The value of ss7iCfgIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iCfgIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.2
The IP address on interface 0 of the HiPer SS7i.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ss7iCfgNetmask 1.3.6.1.4.1.429.1.35.1.1.1.3
The netmask on interface 0 of the HiPer SS7i.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ss7iCfgDfltGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.4
The IP address of the default IP routing gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ss7iCfgProtocol 1.3.6.1.4.1.429.1.35.1.1.1.5
The external signaling protocol running over the TCP/IP connection with the external signaling gateway. Default = hss7iSlapV2(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER slapV2(1)  

ss7iCfgGwConnStartMethod 1.3.6.1.4.1.429.1.35.1.1.1.6
The method used by the HiPer SS7i to bring up the TCP/IP connection to the external signaling gateway at boot time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lsAuto(1), lsManual(2)  

ss7iCfgGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.7
The primary external SS7 gateway IP address. Valid for SLAP only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ss7iCfgGwPort 1.3.6.1.4.1.429.1.35.1.1.1.8
The primary external SS7 gateway port number. Valid for SLAP only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ss7iCfgSecGwIpAddr 1.3.6.1.4.1.429.1.35.1.1.1.9
The secondary external SS7 gateway IP address. Valid for SLAP only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

ss7iCfgSecGwPort 1.3.6.1.4.1.429.1.35.1.1.1.10
The secondary external SS7 gateway port number. Valid for SLAP only.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ss7iCfgHrtbtTimerNearEnd 1.3.6.1.4.1.429.1.35.1.1.1.11
The HiPer SS7i heartbeat timer. Upon expiration, the HiPer SS7i will send a heartbeat message to the external SS7 gateway. The time should be less than what the gateway expects. Valid for SLAP only. Default = 15000 msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..86400000  

ss7iCfgHrtbtTimerFarEnd 1.3.6.1.4.1.429.1.35.1.1.1.12
The external SS7 gateway heartbeat timer. Upon expiration it causes the HiPer SS7i to commence the connection re-establishment procedure to the external SS7 gateway. The time should be longer than what the external SS7 gateway is set to. Valid for SLAP only. Default = 15000 msec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..86400000  

ss7iCfgChassisId 1.3.6.1.4.1.429.1.35.1.1.1.13
This uniquely identifies logical Chassis under the control of the HiPer SS7I, valid for SLAP only. The OCTET STRING format must be FF FF FF FF .
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..4)  

ss7iCfgGwConnRetryCnt 1.3.6.1.4.1.429.1.35.1.1.1.14
The number of times the HiPer SS7i will attempt to re-establish the TCP/IP connection to the external SS7 gateway after the initial failure was detected. Valid for SLAP only. Default = 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ss7iCfgGwConnRetryIntvl 1.3.6.1.4.1.429.1.35.1.1.1.15
The time interval between attempts of the HiPer SS7i to re-establish the TCP/IP connection to the external SS7 gateway. Valid for SLAP only. Default = 2 sec.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ss7iCfgGwMssdHrtbtThrsh 1.3.6.1.4.1.429.1.35.1.1.1.16
The number of external SS7 gateway heartbeat timeouts allowed before the connection to the gateway is considered lost. A setting of 0 means no attempt will be made to re-establish the connection. Default = 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

ss7iCmd 1.3.6.1.4.1.429.1.35.2
OBJECT IDENTIFIER    

ss7iCmdTable 1.3.6.1.4.1.429.1.35.2.1
The Command table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It provides a means through which to take specific actions on them.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iCmdEntry

ss7iCmdEntry 1.3.6.1.4.1.429.1.35.2.1.1
There is one Command Table entry per HiPer SS7i card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iCmdEntry  

ss7iCmdIndex 1.3.6.1.4.1.429.1.35.2.1.1.1
A unique value for each HiPer SS7i card in the chassis. The value of this object matches the value of the index of the corresponding HiPer SS7i card's entry in the entity table of the chassis MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iCmdMgtStationId 1.3.6.1.4.1.429.1.35.2.1.1.2
This object is a generic read-write variable that a Management Station (MS) can use to guarantee that the results from a given command are the results of a command issued by that specific MS. Each MS must SET a unique value to this object when doing commands and GET the value of this object together with ss7iCmdReqId and ss7iCmdResult to detect interference from other MSs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..8)  

ss7iCmdReqId 1.3.6.1.4.1.429.1.35.2.1.1.3
This object contains the value of the request-id field in the SNMP PDU which invoked the current or most recent command or test on this HiPer SS7i card. If the request-id is unknown or undefined, this object contains the value zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iCmdFunction 1.3.6.1.4.1.429.1.35.2.1.1.4
This object contains a value which describes the command which is being invoked.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noCommand(1), saveToNVRAM(2), restoreFromNVRAM(3), restoreFromDefault(4), softwareReset(5), startSS7GwConn(6), shutDownSS7GwConn(7), resetSS7Counters(8), resetPbusCounters(9), startPbusConnToAll(10), stopPbusConnToAll(11)  

ss7iCmdForce 1.3.6.1.4.1.429.1.35.2.1.1.5
In some cases, the HiPer SS7i card may be in a state such that certain commands could adversely affect connections. In such cases, a command request with this object not present or set to noForce will result in a warning. If the operator elects to ignore such warnings, this object can be set to force in a subsequent issue of the command to cause the command to be carried out regardless of its potentially hazzardous effects.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER force(1), noForce(2)  

ss7iCmdParam 1.3.6.1.4.1.429.1.35.2.1.1.6
This object contains parameters that are specific to the particular command being issued. In some cases, there will be no aditional parameters required.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

ss7iCmdResult 1.3.6.1.4.1.429.1.35.2.1.1.7
This object contains the result of the most recently requested command or test, or the value none(1) if no commands have been requested since the last reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7)  

ss7iCmdCode 1.3.6.1.4.1.429.1.35.2.1.1.8
The value of this object upon command completion indicates a further description of what went wrong if the command was unsuccessful. In the case of tests, a bit mapped result of each of the sub-tests performed can be found in the status table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), unable(2), unrecognizedCommand(6), slotEmpty(8), noResponse(12), unsupportedCommand(20), deviceDisabled(22), testFailed(25), userInterfaceActive(58), pendingSoftwareDownload(73)  

ss7iTrap 1.3.6.1.4.1.429.1.35.3
OBJECT IDENTIFIER    

ss7iTrapTable 1.3.6.1.4.1.429.1.35.3.1
Table containing objects to enable traps on the HiPer SS7i cards in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iTrapEntry

ss7iTrapEntry 1.3.6.1.4.1.429.1.35.3.1.1
There is one entry for each HiPer SS7i card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iTrapEntry  

ss7iTrapIndex 1.3.6.1.4.1.429.1.35.3.1.1.1
A unique index identifying the HiPer SS7i card to which the trap enable objects pertain.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iTrapPbusLinkUp 1.3.6.1.4.1.429.1.35.3.1.1.2
Enables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp comes up. Default = disableAll(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

ss7iTrapPbusLinkDown 1.3.6.1.4.1.429.1.35.3.1.1.3
Enables reporting of a trap and/or log message when the ENFAS packet bus signaling link to the HiPer Dsp goes down. Default = disableAll(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

ss7iTrapGwConnUp 1.3.6.1.4.1.429.1.35.3.1.1.4
Enables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway comes up. Default = disableAll(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

ss7iTrapGwConnDown 1.3.6.1.4.1.429.1.35.3.1.1.5
Enables reporting of a trap and/or log message when the TCP/IP signaling connection to the SS7 (or media) gateway goes down. Default = disableAll(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableAll(2), enableLog(3), enableAll(4)  

ss7iStat 1.3.6.1.4.1.429.1.35.4
OBJECT IDENTIFIER    

ss7iStatTable 1.3.6.1.4.1.429.1.35.4.1
The Statistics table contains an entry for each of the manageable HiPer SS7i cards in the chassis. It contains objects that reflect the current status of the card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iStatEntry

ss7iStatEntry 1.3.6.1.4.1.429.1.35.4.1.1
There is one Statistics table entry for each HiPer SS7i card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iStatEntry  

ss7iStatIndex 1.3.6.1.4.1.429.1.35.4.1.1.1
A unique value for each HiPer SS7i card in the chassis. The value of ss7iStatIndex matches the value of the index for the corresponding Hiper SS7i card entity in the entity table of the chassis MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iStatGwConnStatus 1.3.6.1.4.1.429.1.35.4.1.1.2
Status of the TCP/IP connection with the external signaling gateway. Valid for SLAP only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

ss7iStatGwNumMsgsRcvd 1.3.6.1.4.1.429.1.35.4.1.1.3
The number of messages received from the external SS7 gateway or the Media Gateway Controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwNumBytesRcvd 1.3.6.1.4.1.429.1.35.4.1.1.4
The number of bytes received from the external SS7 gateway or the Media Gateway Controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwNumMsgsSent 1.3.6.1.4.1.429.1.35.4.1.1.5
The number of messages sent to the external SS7 gateway or the Media Gateway Controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwNumBytesSent 1.3.6.1.4.1.429.1.35.4.1.1.6
The number of bytes sent to the external SS7 gateway or the Media Gateway Controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwMssdHrtbtCnt 1.3.6.1.4.1.429.1.35.4.1.1.7
The accumulated number of missed heartbeat messages expected to arrive from the external SS7 gateway.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwLinkLostCnt 1.3.6.1.4.1.429.1.35.4.1.1.8
The accumulated number of times the physical Ethernet connection is unplugged or severed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwLinkErrCnt 1.3.6.1.4.1.429.1.35.4.1.1.9
The accumulated number of errors encountered sending to or receiving from the external SS7 gateway when the TCP/IP connection is believed to be healthy.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iStatGwLinkDownCause 1.3.6.1.4.1.429.1.35.4.1.1.10
The reason the signaling connection to the external SS7 gateway went down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), heartbeatTimeout(2), socketSndRcvError(3), physicalLinkSevered(4)  

ss7iHdm 1.3.6.1.4.1.429.1.35.5
OBJECT IDENTIFIER    

ss7iHdmTable 1.3.6.1.4.1.429.1.35.5.1
The ss7iHdm table contains objects for all of the HiPer Dsp cards in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iHdmEntry

ss7iHdmEntry 1.3.6.1.4.1.429.1.35.5.1.1
There is one entry for each HiPer Dsp Card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iHdmEntry  

ss7iHdmIndex 1.3.6.1.4.1.429.1.35.5.1.1.1
A unique value for each HiPer SS7i card in the chassis. The value of ss7iHdmIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iHdmIndex2 1.3.6.1.4.1.429.1.35.5.1.1.2
The secondary index into the ss7iHdm table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number of a HiPer Dsp card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iHdmConnState 1.3.6.1.4.1.429.1.35.5.1.1.3
The state of the signaling packet bus connection to the HiPer Dsp. There is one connection from the HiPer SS7i card to each HiPer Dsp in the chassis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER closed(1), opening(2), opened(3), configuring(4), ready(5), closing(6), loopback(7)  

ss7iHdmSndPktsOkCnt 1.3.6.1.4.1.429.1.35.5.1.1.4
The number of packets successfully transmitted over the signaling packet bus connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iHdmSndPktsFailCnt 1.3.6.1.4.1.429.1.35.5.1.1.5
The number of packets failing to transmit over the signaling packet bus connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iHdmRcvPktsOkCnt 1.3.6.1.4.1.429.1.35.5.1.1.6
The number of packets sucessfully received over the signaling packet bus connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iHdmRcvPktsFailCnt 1.3.6.1.4.1.429.1.35.5.1.1.7
The number of signaling packet bus connection packets rejected by the HiPer SS7i message handler.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

ss7iHdmLinkDownCause 1.3.6.1.4.1.429.1.35.5.1.1.8
The reason the packet bus ENFAS signaling link to the HiPer Dsp went down.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), missingHdm(2), ss7GwLinkDown(3), pbusSndRcvError(4)  

ss7iSigPb 1.3.6.1.4.1.429.1.35.6
OBJECT IDENTIFIER    

ss7iSigPbTable 1.3.6.1.4.1.429.1.35.6.1
The ss7iSigPb table contains objects for managing the signaling packet bus connections to all of the HiPer Dsp cards in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ss7iSigPbEntry

ss7iSigPbEntry 1.3.6.1.4.1.429.1.35.6.1.1
There is one entry for each HiPer Dsp Card in the chassis.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Ss7iSigPbEntry  

ss7iSigPbIndex 1.3.6.1.4.1.429.1.35.6.1.1.1
A unique value for each HiPer SS7i card in the chassis. The value of ss7iSigPbIndex matches the value of the index for the corresponding HiPer SS7i card entity in the entity table of the chassis MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iSigPbIndex2 1.3.6.1.4.1.429.1.35.6.1.1.2
The secondary index into the ss7iSigPb table. There is one entry for each Hiper Dsp in the chassis. The value of the index is equal to the chassis slot number of a HiPer Dsp card.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

ss7iSigPbConnection 1.3.6.1.4.1.429.1.35.6.1.1.3
The means to enable or disable a signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

ss7iSigPbLoopback 1.3.6.1.4.1.429.1.35.6.1.1.4
The means to enable or disable the loopback state on the signaling packet bus connection between the HiPer SS7i and a Hiper Dsp. Default = disable(1).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)