SS7I-MIB
File:
SS7I-MIB.mib (21756 bytes)
Imported modules
Imported symbols
Defined Types
Ss7iCfgEntry |
|
SEQUENCE |
|
|
|
|
ss7iCfgIndex |
INTEGER |
|
|
ss7iCfgIpAddr |
IpAddress |
|
|
ss7iCfgNetmask |
IpAddress |
|
|
ss7iCfgDfltGwIpAddr |
IpAddress |
|
|
ss7iCfgProtocol |
INTEGER |
|
|
ss7iCfgGwConnStartMethod |
INTEGER |
|
|
ss7iCfgGwIpAddr |
IpAddress |
|
|
ss7iCfgGwPort |
INTEGER |
|
|
ss7iCfgSecGwIpAddr |
IpAddress |
|
|
ss7iCfgSecGwPort |
INTEGER |
|
|
ss7iCfgHrtbtTimerNearEnd |
INTEGER |
|
|
ss7iCfgHrtbtTimerFarEnd |
INTEGER |
|
|
ss7iCfgChassisId |
OCTET STRING |
|
|
ss7iCfgGwConnRetryCnt |
INTEGER |
|
|
ss7iCfgGwConnRetryIntvl |
INTEGER |
|
|
ss7iCfgGwMssdHrtbtThrsh |
INTEGER |
|
Ss7iCmdEntry |
|
SEQUENCE |
|
|
|
|
ss7iCmdIndex |
INTEGER |
|
|
ss7iCmdMgtStationId |
OCTET STRING |
|
|
ss7iCmdReqId |
INTEGER |
|
|
ss7iCmdFunction |
INTEGER |
|
|
ss7iCmdForce |
INTEGER |
|
|
ss7iCmdParam |
OCTET STRING |
|
|
ss7iCmdResult |
INTEGER |
|
|
ss7iCmdCode |
INTEGER |
|
Ss7iTrapEntry |
|
SEQUENCE |
|
|
|
|
ss7iTrapIndex |
INTEGER |
|
|
ss7iTrapPbusLinkUp |
INTEGER |
|
|
ss7iTrapPbusLinkDown |
INTEGER |
|
|
ss7iTrapGwConnUp |
INTEGER |
|
|
ss7iTrapGwConnDown |
INTEGER |
|
Ss7iStatEntry |
|
SEQUENCE |
|
|
|
|
ss7iStatIndex |
INTEGER |
|
|
ss7iStatGwConnStatus |
INTEGER |
|
|
ss7iStatGwNumMsgsRcvd |
Counter |
|
|
ss7iStatGwNumBytesRcvd |
Counter |
|
|
ss7iStatGwNumMsgsSent |
Counter |
|
|
ss7iStatGwNumBytesSent |
Counter |
|
|
ss7iStatGwMssdHrtbtCnt |
Counter |
|
|
ss7iStatGwLinkLostCnt |
Counter |
|
|
ss7iStatGwLinkErrCnt |
Counter |
|
|
ss7iStatGwLinkDownCause |
INTEGER |
|
Ss7iHdmEntry |
|
SEQUENCE |
|
|
|
|
ss7iHdmIndex |
INTEGER |
|
|
ss7iHdmIndex2 |
INTEGER |
|
|
ss7iHdmConnState |
INTEGER |
|
|
ss7iHdmSndPktsOkCnt |
Counter |
|
|
ss7iHdmSndPktsFailCnt |
Counter |
|
|
ss7iHdmRcvPktsOkCnt |
Counter |
|
|
ss7iHdmRcvPktsFailCnt |
Counter |
|
|
ss7iHdmLinkDownCause |
INTEGER |
|
Ss7iSigPbEntry |
|
SEQUENCE |
|
|
|
|
ss7iSigPbIndex |
INTEGER |
|
|
ss7iSigPbIndex2 |
INTEGER |
|
|
ss7iSigPbConnection |
INTEGER |
|
|
ss7iSigPbLoopback |
INTEGER |
|
Defined Values
usr |
1.3.6.1.4.1.429 |
OBJECT IDENTIFIER |
|
|
|
nas |
1.3.6.1.4.1.429.1 |
OBJECT IDENTIFIER |
|
|
|
ss7i |
1.3.6.1.4.1.429.1.35 |
OBJECT IDENTIFIER |
|
|
|
ss7iCfg |
1.3.6.1.4.1.429.1.35.1 |
OBJECT IDENTIFIER |
|
|
|
ss7iCfgTable |
1.3.6.1.4.1.429.1.35.1.1 |
The Configuration Table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It contains
objects that reflect the current configuration of
parameters that affect the operation of all the entities
that reside on the given card. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iCfgEntry |
|
ss7iCfgEntry |
1.3.6.1.4.1.429.1.35.1.1.1 |
There is one Configuration Table entry per HiPer SS7i Card
in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iCfgEntry |
|
|
ss7iCfgIndex |
1.3.6.1.4.1.429.1.35.1.1.1.1 |
A unique value for each HiPer SS7i card in the chassis.
The value of ss7iCfgIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCfgIpAddr |
1.3.6.1.4.1.429.1.35.1.1.1.2 |
The IP address on interface 0 of the HiPer SS7i. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ss7iCfgNetmask |
1.3.6.1.4.1.429.1.35.1.1.1.3 |
The netmask on interface 0 of the HiPer SS7i. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ss7iCfgDfltGwIpAddr |
1.3.6.1.4.1.429.1.35.1.1.1.4 |
The IP address of the default IP routing gateway. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ss7iCfgProtocol |
1.3.6.1.4.1.429.1.35.1.1.1.5 |
The external signaling protocol running over the TCP/IP
connection with the external signaling gateway. Default =
hss7iSlapV2(1). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
slapV2(1) |
|
ss7iCfgGwConnStartMethod |
1.3.6.1.4.1.429.1.35.1.1.1.6 |
The method used by the HiPer SS7i to bring up the TCP/IP
connection to the external signaling gateway at boot time. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
lsAuto(1), lsManual(2) |
|
ss7iCfgGwIpAddr |
1.3.6.1.4.1.429.1.35.1.1.1.7 |
The primary external SS7 gateway IP address. Valid for
SLAP only. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ss7iCfgGwPort |
1.3.6.1.4.1.429.1.35.1.1.1.8 |
The primary external SS7 gateway port number. Valid for
SLAP only. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCfgSecGwIpAddr |
1.3.6.1.4.1.429.1.35.1.1.1.9 |
The secondary external SS7 gateway IP address. Valid for
SLAP only. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ss7iCfgSecGwPort |
1.3.6.1.4.1.429.1.35.1.1.1.10 |
The secondary external SS7 gateway port number. Valid for
SLAP only. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCfgHrtbtTimerNearEnd |
1.3.6.1.4.1.429.1.35.1.1.1.11 |
The HiPer SS7i heartbeat timer. Upon expiration, the HiPer
SS7i will send a heartbeat message to the external SS7
gateway. The time should be less than what the gateway
expects. Valid for SLAP only. Default = 15000 msec. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..86400000 |
|
ss7iCfgHrtbtTimerFarEnd |
1.3.6.1.4.1.429.1.35.1.1.1.12 |
The external SS7 gateway heartbeat timer. Upon expiration
it causes the HiPer SS7i to commence the connection
re-establishment procedure to the external SS7 gateway.
The time should be longer than what the external SS7
gateway is set to. Valid for SLAP only. Default = 15000
msec. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..86400000 |
|
ss7iCfgChassisId |
1.3.6.1.4.1.429.1.35.1.1.1.13 |
This uniquely identifies logical Chassis under the control
of the HiPer SS7I, valid for SLAP only. The OCTET STRING
format must be FF FF FF FF . |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..4) |
|
ss7iCfgGwConnRetryCnt |
1.3.6.1.4.1.429.1.35.1.1.1.14 |
The number of times the HiPer SS7i will attempt to
re-establish the TCP/IP connection to the external SS7
gateway after the initial failure was detected. Valid for
SLAP only. Default = 3. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCfgGwConnRetryIntvl |
1.3.6.1.4.1.429.1.35.1.1.1.15 |
The time interval between attempts of the HiPer SS7i to
re-establish the TCP/IP connection to the external SS7
gateway. Valid for SLAP only. Default = 2 sec. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCfgGwMssdHrtbtThrsh |
1.3.6.1.4.1.429.1.35.1.1.1.16 |
The number of external SS7 gateway heartbeat timeouts
allowed before the connection to the gateway is considered
lost. A setting of 0 means no attempt will be made to
re-establish the connection. Default = 1. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCmd |
1.3.6.1.4.1.429.1.35.2 |
OBJECT IDENTIFIER |
|
|
|
ss7iCmdTable |
1.3.6.1.4.1.429.1.35.2.1 |
The Command table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It provides a
means through which to take specific actions on them. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iCmdEntry |
|
ss7iCmdEntry |
1.3.6.1.4.1.429.1.35.2.1.1 |
There is one Command Table entry per HiPer SS7i card in the
chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iCmdEntry |
|
|
ss7iCmdIndex |
1.3.6.1.4.1.429.1.35.2.1.1.1 |
A unique value for each HiPer SS7i card in the chassis.
The value of this object matches the value of the index of
the corresponding HiPer SS7i card's entry in the entity
table of the chassis MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCmdMgtStationId |
1.3.6.1.4.1.429.1.35.2.1.1.2 |
This object is a generic read-write variable that a
Management Station (MS) can use to guarantee that the
results from a given command are the results of a command
issued by that specific MS. Each MS must SET a unique
value to this object when doing commands and GET the value
of this object together with ss7iCmdReqId and ss7iCmdResult
to detect interference from other MSs. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..8) |
|
ss7iCmdReqId |
1.3.6.1.4.1.429.1.35.2.1.1.3 |
This object contains the value of the request-id field in
the SNMP PDU which invoked the current or most recent
command or test on this HiPer SS7i card. If the request-id
is unknown or undefined, this object contains the value
zero. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iCmdFunction |
1.3.6.1.4.1.429.1.35.2.1.1.4 |
This object contains a value which describes the command
which is being invoked. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noCommand(1), saveToNVRAM(2), restoreFromNVRAM(3), restoreFromDefault(4), softwareReset(5), startSS7GwConn(6), shutDownSS7GwConn(7), resetSS7Counters(8), resetPbusCounters(9), startPbusConnToAll(10), stopPbusConnToAll(11) |
|
ss7iCmdForce |
1.3.6.1.4.1.429.1.35.2.1.1.5 |
In some cases, the HiPer SS7i card may be in a state such
that certain commands could adversely affect connections.
In such cases, a command request with this object not
present or set to noForce will result in a warning. If the
operator elects to ignore such warnings, this object can be
set to force in a subsequent issue of the command to cause
the command to be carried out regardless of its potentially
hazzardous effects. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
force(1), noForce(2) |
|
ss7iCmdParam |
1.3.6.1.4.1.429.1.35.2.1.1.6 |
This object contains parameters that are specific to the
particular command being issued. In some cases, there will
be no aditional parameters required. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ss7iCmdResult |
1.3.6.1.4.1.429.1.35.2.1.1.7 |
This object contains the result of the most recently
requested command or test, or the value none(1) if no
commands have been requested since the last reset. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), success(2), inProgress(3), notSupported(4), unAbleToRun(5), aborted(6), failed(7) |
|
ss7iCmdCode |
1.3.6.1.4.1.429.1.35.2.1.1.8 |
The value of this object upon command completion indicates
a further description of what went wrong if the command was
unsuccessful. In the case of tests, a bit mapped result of
each of the sub-tests performed can be found in the status
table. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noError(1), unable(2), unrecognizedCommand(6), slotEmpty(8), noResponse(12), unsupportedCommand(20), deviceDisabled(22), testFailed(25), userInterfaceActive(58), pendingSoftwareDownload(73) |
|
ss7iTrap |
1.3.6.1.4.1.429.1.35.3 |
OBJECT IDENTIFIER |
|
|
|
ss7iTrapTable |
1.3.6.1.4.1.429.1.35.3.1 |
Table containing objects to enable traps on the HiPer SS7i
cards in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iTrapEntry |
|
ss7iTrapEntry |
1.3.6.1.4.1.429.1.35.3.1.1 |
There is one entry for each HiPer SS7i card in the
chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iTrapEntry |
|
|
ss7iTrapIndex |
1.3.6.1.4.1.429.1.35.3.1.1.1 |
A unique index identifying the HiPer SS7i card to which the
trap enable objects pertain. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iTrapPbusLinkUp |
1.3.6.1.4.1.429.1.35.3.1.1.2 |
Enables reporting of a trap and/or log message when the
ENFAS packet bus signaling link to the HiPer Dsp comes up.
Default = disableAll(2). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enableTrap(1), disableAll(2), enableLog(3), enableAll(4) |
|
ss7iTrapPbusLinkDown |
1.3.6.1.4.1.429.1.35.3.1.1.3 |
Enables reporting of a trap and/or log message when the
ENFAS packet bus signaling link to the HiPer Dsp goes down.
Default = disableAll(2). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enableTrap(1), disableAll(2), enableLog(3), enableAll(4) |
|
ss7iTrapGwConnUp |
1.3.6.1.4.1.429.1.35.3.1.1.4 |
Enables reporting of a trap and/or log message when the
TCP/IP signaling connection to the SS7 (or media) gateway
comes up. Default = disableAll(2). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enableTrap(1), disableAll(2), enableLog(3), enableAll(4) |
|
ss7iTrapGwConnDown |
1.3.6.1.4.1.429.1.35.3.1.1.5 |
Enables reporting of a trap and/or log message when the
TCP/IP signaling connection to the SS7 (or media) gateway
goes down. Default = disableAll(2). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enableTrap(1), disableAll(2), enableLog(3), enableAll(4) |
|
ss7iStat |
1.3.6.1.4.1.429.1.35.4 |
OBJECT IDENTIFIER |
|
|
|
ss7iStatTable |
1.3.6.1.4.1.429.1.35.4.1 |
The Statistics table contains an entry for each of the
manageable HiPer SS7i cards in the chassis. It contains
objects that reflect the current status of the card. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iStatEntry |
|
ss7iStatEntry |
1.3.6.1.4.1.429.1.35.4.1.1 |
There is one Statistics table entry for each HiPer SS7i
card in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iStatEntry |
|
|
ss7iStatIndex |
1.3.6.1.4.1.429.1.35.4.1.1.1 |
A unique value for each HiPer SS7i card in the chassis.
The value of ss7iStatIndex matches the value of the index
for the corresponding Hiper SS7i card entity in the entity
table of the chassis MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iStatGwConnStatus |
1.3.6.1.4.1.429.1.35.4.1.1.2 |
Status of the TCP/IP connection with the external signaling
gateway. Valid for SLAP only. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2) |
|
ss7iStatGwNumMsgsRcvd |
1.3.6.1.4.1.429.1.35.4.1.1.3 |
The number of messages received from the external SS7
gateway or the Media Gateway Controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwNumBytesRcvd |
1.3.6.1.4.1.429.1.35.4.1.1.4 |
The number of bytes received from the external SS7 gateway
or the Media Gateway Controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwNumMsgsSent |
1.3.6.1.4.1.429.1.35.4.1.1.5 |
The number of messages sent to the external SS7 gateway or
the Media Gateway Controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwNumBytesSent |
1.3.6.1.4.1.429.1.35.4.1.1.6 |
The number of bytes sent to the external SS7 gateway or the
Media Gateway Controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwMssdHrtbtCnt |
1.3.6.1.4.1.429.1.35.4.1.1.7 |
The accumulated number of missed heartbeat messages
expected to arrive from the external SS7 gateway. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwLinkLostCnt |
1.3.6.1.4.1.429.1.35.4.1.1.8 |
The accumulated number of times the physical Ethernet
connection is unplugged or severed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwLinkErrCnt |
1.3.6.1.4.1.429.1.35.4.1.1.9 |
The accumulated number of errors encountered sending to or
receiving from the external SS7 gateway when the TCP/IP
connection is believed to be healthy. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iStatGwLinkDownCause |
1.3.6.1.4.1.429.1.35.4.1.1.10 |
The reason the signaling connection to the external SS7
gateway went down. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), heartbeatTimeout(2), socketSndRcvError(3), physicalLinkSevered(4) |
|
ss7iHdm |
1.3.6.1.4.1.429.1.35.5 |
OBJECT IDENTIFIER |
|
|
|
ss7iHdmTable |
1.3.6.1.4.1.429.1.35.5.1 |
The ss7iHdm table contains objects for all of the HiPer Dsp
cards in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iHdmEntry |
|
ss7iHdmEntry |
1.3.6.1.4.1.429.1.35.5.1.1 |
There is one entry for each HiPer Dsp Card in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iHdmEntry |
|
|
ss7iHdmIndex |
1.3.6.1.4.1.429.1.35.5.1.1.1 |
A unique value for each HiPer SS7i card in the chassis.
The value of ss7iHdmIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iHdmIndex2 |
1.3.6.1.4.1.429.1.35.5.1.1.2 |
The secondary index into the ss7iHdm table. There is one
entry for each Hiper Dsp in the chassis. The value of the
index is equal to the chassis slot number of a HiPer Dsp
card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iHdmConnState |
1.3.6.1.4.1.429.1.35.5.1.1.3 |
The state of the signaling packet bus connection to the
HiPer Dsp. There is one connection from the HiPer SS7i
card to each HiPer Dsp in the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
closed(1), opening(2), opened(3), configuring(4), ready(5), closing(6), loopback(7) |
|
ss7iHdmSndPktsOkCnt |
1.3.6.1.4.1.429.1.35.5.1.1.4 |
The number of packets successfully transmitted over the
signaling packet bus connection. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iHdmSndPktsFailCnt |
1.3.6.1.4.1.429.1.35.5.1.1.5 |
The number of packets failing to transmit over the
signaling packet bus connection. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iHdmRcvPktsOkCnt |
1.3.6.1.4.1.429.1.35.5.1.1.6 |
The number of packets sucessfully received over the
signaling packet bus connection. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iHdmRcvPktsFailCnt |
1.3.6.1.4.1.429.1.35.5.1.1.7 |
The number of signaling packet bus connection packets
rejected by the HiPer SS7i message handler. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ss7iHdmLinkDownCause |
1.3.6.1.4.1.429.1.35.5.1.1.8 |
The reason the packet bus ENFAS signaling link to the HiPer
Dsp went down. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), missingHdm(2), ss7GwLinkDown(3), pbusSndRcvError(4) |
|
ss7iSigPb |
1.3.6.1.4.1.429.1.35.6 |
OBJECT IDENTIFIER |
|
|
|
ss7iSigPbTable |
1.3.6.1.4.1.429.1.35.6.1 |
The ss7iSigPb table contains objects for managing the
signaling packet bus connections to all of the HiPer Dsp
cards in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Ss7iSigPbEntry |
|
ss7iSigPbEntry |
1.3.6.1.4.1.429.1.35.6.1.1 |
There is one entry for each HiPer Dsp Card in the chassis. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Ss7iSigPbEntry |
|
|
ss7iSigPbIndex |
1.3.6.1.4.1.429.1.35.6.1.1.1 |
A unique value for each HiPer SS7i card in the chassis.
The value of ss7iSigPbIndex matches the value of the index
for the corresponding HiPer SS7i card entity in the entity
table of the chassis MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iSigPbIndex2 |
1.3.6.1.4.1.429.1.35.6.1.1.2 |
The secondary index into the ss7iSigPb table. There is one
entry for each Hiper Dsp in the chassis. The value of the
index is equal to the chassis slot number of a HiPer Dsp
card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ss7iSigPbConnection |
1.3.6.1.4.1.429.1.35.6.1.1.3 |
The means to enable or disable a signaling packet bus
connection between the HiPer SS7i and a Hiper Dsp. Default
= disable(1). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), enable(2) |
|
ss7iSigPbLoopback |
1.3.6.1.4.1.429.1.35.6.1.1.4 |
The means to enable or disable the loopback state on the
signaling packet bus connection between the HiPer SS7i and
a Hiper Dsp. Default = disable(1). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(1), enable(2) |
|