SONUS-SYSTEM-TIMING-MIB

File: SONUS-SYSTEM-TIMING-MIB.mib (32635 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SONUS-COMMON-MIB
SONUS-SMI SONUS-TC

Imported symbols

Integer32 MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE DisplayString RowStatus
sonusEventClass sonusEventDescription sonusEventLevel
sonusShelfIndex sonusSlotIndex sonusSystemMIBs
HwTypeID SonusAdminState SonusEventString
SonusMtaSlotIndex SonusShelfIndex SonusSlotIndex
SonusTimingSource

Defined Types

SonusStShelfAdmnEntry  
SEQUENCE    
  sonusStShelfAdmnShelfIndex SonusShelfIndex
  sonusStShelfAdmnFailoverGuardTime Integer32
  sonusStShelfAdmnRecoveryGuardTime Integer32
  sonusStShelfAdmnTransmitRemoteAlarm INTEGER
  sonusStShelfAdmnRevertRefSwitching INTEGER
  sonusStShelfAdmnRevertMtaSwitching INTEGER
  sonusStShelfAdmnRevertInsertDelay Integer32
  sonusStShelfAdmnFreeRunAlarm INTEGER
  sonusStShelfAdmnTimingSourceAction INTEGER
  sonusStShelfAdmnRowStatus RowStatus
  sonusStShelfAdmnSourceReconfigAlg INTEGER
  sonusStShelfAdmnMtaSourceAffinity INTEGER

SonusStShelfStatEntry  
SEQUENCE    
  sonusStShelfStatShelfIndex SonusShelfIndex
  sonusStShelfStatActiveMtaSlot SonusMtaSlotIndex
  sonusStShelfStatActiveSource SonusTimingSource

SonusStMtaAdmnEntry  
SEQUENCE    
  sonusStMtaAdmnShelfIndex SonusShelfIndex
  sonusStMtaAdmnMtaSlotIndex SonusMtaSlotIndex
  sonusStMtaAdmnState SonusAdminState
  sonusStMtaAdmnLineEncoding INTEGER
  sonusStMtaAdmnSsmChannelBit INTEGER
  sonusStMtaAdmnFramerMode INTEGER
  sonusStMtaAdmnFramerTransmitYellowAlarm INTEGER
  sonusStMtaAdmnLiuTransmitAllOnes INTEGER
  sonusStMtaAdmnAction INTEGER
  sonusStMtaAdmnRowStatus RowStatus

SonusStMtaStatEntry  
SEQUENCE    
  sonusStMtaStatShelfIndex SonusShelfIndex
  sonusStMtaStatMtaSlotIndex SonusMtaSlotIndex
  sonusStMtaStatOperStat INTEGER
  sonusStMtaStatMtaHwDesc DisplayString
  sonusStMtaStatMtaHwType HwTypeID
  sonusStMtaStatMtaHwTypeRev Integer32
  sonusStMtaStatMtaSerialNum DisplayString
  sonusStMtaStatMtaPartNum DisplayString

SonusStTimingSourceEntry  
SEQUENCE    
  sonusStTimingSourceShelfIndex SonusShelfIndex
  sonusStTimingSourceMtaSlotIndex Integer32
  sonusStTimingSource SonusTimingSource
  sonusStTimingSourceState SonusAdminState
  sonusStTimingSourceSequenceNum Integer32
  sonusStTimingSourceAction INTEGER
  sonusStTimingSourceRowStatus RowStatus

SonusStTimingSourceStatEntry  
SEQUENCE    
  sonusStTimingSourceStatShelfIndex SonusShelfIndex
  sonusStTimingSourceStatMtaSlotIndex SonusMtaSlotIndex
  sonusStTimingSourceStat SonusTimingSource
  sonusStTimingSourceStatState INTEGER
  sonusStTimingSourceStatTraceability INTEGER
  sonusStTimingSourceStatLineState INTEGER

SonusStChannelBindingEntry  
SEQUENCE    
  sonusStChannelBindingShelfIndex SonusShelfIndex
  sonusStChannelBindingSlotIndex SonusSlotIndex
  sonusStChannelBindingChannel Integer32
  sonusStChannelBindingRefClk INTEGER
  sonusStChannelBindingRowStatus RowStatus

Defined Values

sonusSystemTimingMIB 1.3.6.1.4.1.2879.2.1.3
The MIB Module for System Timing management.
MODULE-IDENTITY    

sonusSystemTimingMIBObjects 1.3.6.1.4.1.2879.2.1.3.1
OBJECT IDENTIFIER    

sonusStShelfAdmnTable 1.3.6.1.4.1.2879.2.1.3.1.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStShelfAdmnEntry

sonusStShelfAdmnEntry 1.3.6.1.4.1.2879.2.1.3.1.1.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStShelfAdmnEntry  

sonusStShelfAdmnShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.1.1.1
Identifies the target shelf within the node.
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStShelfAdmnFailoverGuardTime 1.3.6.1.4.1.2879.2.1.3.1.1.1.2
Indicates how long a timing source can be faulting before switchover to another source is initiated
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..5  

sonusStShelfAdmnRecoveryGuardTime 1.3.6.1.4.1.2879.2.1.3.1.1.1.3
Indicates how long a timing source must be valid for, after it has faulted, before it will be considered valid again.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 15..120  

sonusStShelfAdmnTransmitRemoteAlarm 1.3.6.1.4.1.2879.2.1.3.1.1.1.4
Not Supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStShelfAdmnRevertRefSwitching 1.3.6.1.4.1.2879.2.1.3.1.1.1.5
If enabled, then a timing source which has failed, but then becomes valid again, will be reconsidered for use. If disabled, then once a timing source fails, it will never be automatically reconsidered for use. To use the source again requires manual user intervention.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStShelfAdmnRevertMtaSwitching 1.3.6.1.4.1.2879.2.1.3.1.1.1.6
If enabled, then an MTA which is hot-inserted will automatically be brought on line and made available for use. If disabled, then an MTA which is hot-inserted will require manual user configuration before being available for use.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStShelfAdmnRevertInsertDelay 1.3.6.1.4.1.2879.2.1.3.1.1.1.7
MTA warm-up period. When an MTA is hot-inserted, the card will be allowed to warm up and stabilize for this amount of time before being put back into service. This warm-up period is also used during cold start of a shelf.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 100..300  

sonusStShelfAdmnFreeRunAlarm 1.3.6.1.4.1.2879.2.1.3.1.1.1.8
Not Supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStShelfAdmnTimingSourceAction 1.3.6.1.4.1.2879.2.1.3.1.1.1.9
Resequence will cause the timing sequence list to be re-evaluated. This may cause the current active timing source to change.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), resequence(2)  

sonusStShelfAdmnRowStatus 1.3.6.1.4.1.2879.2.1.3.1.1.1.10
This object indicates the row status for this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusStShelfAdmnSourceReconfigAlg 1.3.6.1.4.1.2879.2.1.3.1.1.1.11
This object indicates which algorithm should be used to select timing sources for use as System Synchronized sources. Selecting Ordered_list causes sources to be selected for use in strict numerical order, as assigned by default or by the operator. Selecting SSM_Quality will cause sources to be selected based upon the quality level of the timing source, as indicated by the sources Synchronized Status Messages. Do not select SSM_Quality unless all configured timing sources support SSM's
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ordered-list(1), ssm-quality(2)  

sonusStShelfAdmnMtaSourceAffinity 1.3.6.1.4.1.2879.2.1.3.1.1.1.12
This object works in conjunction with the Source Reconfiguration Algorithm object. If sticky is selected, System Timing Manager will exhaust oll timing sources on an MTA at all quality levels before selecting a timing source on the alternate MTA. If none is selected, timing sources will be chosen based on stratum quality only, reguardless of which MTA is providing the source. This object has no effect when the Source Reconfiguration Algorithm is set to Ordered_list.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), sticky(2)  

sonusStShelfStatTable 1.3.6.1.4.1.2879.2.1.3.1.2
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStShelfStatEntry

sonusStShelfStatEntry 1.3.6.1.4.1.2879.2.1.3.1.2.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStShelfStatEntry  

sonusStShelfStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.2.1.1
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStShelfStatActiveMtaSlot 1.3.6.1.4.1.2879.2.1.3.1.2.1.2
Identifies which MTA is providing the System Synchronized Timing signal.
Status: current Access: read-only
OBJECT-TYPE    
  SonusMtaSlotIndex  

sonusStShelfStatActiveSource 1.3.6.1.4.1.2879.2.1.3.1.2.1.3
Identifies what timing source the active MTA is using to provide System Synchronized Timing.
Status: current Access: read-only
OBJECT-TYPE    
  SonusTimingSource  

sonusStMtaAdmnTable 1.3.6.1.4.1.2879.2.1.3.1.3
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStMtaAdmnEntry

sonusStMtaAdmnEntry 1.3.6.1.4.1.2879.2.1.3.1.3.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStMtaAdmnEntry  

sonusStMtaAdmnShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.3.1.1
Identifies the target shelf within the node.
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStMtaAdmnMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.3.1.2
Identifies the target slot within the shelf.
Status: current Access: read-only
OBJECT-TYPE    
  SonusMtaSlotIndex  

sonusStMtaAdmnState 1.3.6.1.4.1.2879.2.1.3.1.3.1.3
If enabled, the MTA can participate in system timing. If disabled, then it will be removed from service and not allowed to participate. All timing sequence entries bound to this node will be marked as out of service. In a non-redundant configuration the MTA admin state cannot be disabled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusStMtaAdmnLineEncoding 1.3.6.1.4.1.2879.2.1.3.1.3.1.4
Select AMI or B8ZS line coding for BITS LIU. Select HDB3 for SETS LIU
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ami(1), b8zs(2), hdb3(3)  

sonusStMtaAdmnSsmChannelBit 1.3.6.1.4.1.2879.2.1.3.1.3.1.5
MTA 20, E1 support only. Identifies which of the additional spare bits, embedded within the framing pattern, contains the SSM channel
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER sa4(1), sa5(2), sa6(3), sa7(4), sa8(5)  

sonusStMtaAdmnFramerMode 1.3.6.1.4.1.2879.2.1.3.1.3.1.6
Select ESF or D4/SF for BITS framer. ESF should be selected if B8ZS has been selected for the line encoding. D4/SF should be selected if AMI has been selected for the line encoding. Select MF or MF-CRC4 for SETS framer
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER d4sf(1), esf(2), mf(3), mf-crc4(4)  

sonusStMtaAdmnFramerTransmitYellowAlarm 1.3.6.1.4.1.2879.2.1.3.1.3.1.7
Not supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStMtaAdmnLiuTransmitAllOnes 1.3.6.1.4.1.2879.2.1.3.1.3.1.8
Not supported
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sonusStMtaAdmnAction 1.3.6.1.4.1.2879.2.1.3.1.3.1.9
Selecting AVAILABLE will cause the MTA to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make an MTA available for use after it has failed, and revertive MTA switching is not enabled. This may cause the current active timing source to change.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), available(2)  

sonusStMtaAdmnRowStatus 1.3.6.1.4.1.2879.2.1.3.1.3.1.10
This object indicates the row status for this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusStMtaStatTable 1.3.6.1.4.1.2879.2.1.3.1.4
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStMtaStatEntry

sonusStMtaStatEntry 1.3.6.1.4.1.2879.2.1.3.1.4.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStMtaStatEntry  

sonusStMtaStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.4.1.1
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStMtaStatMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.4.1.2
Status: current Access: read-only
OBJECT-TYPE    
  SonusMtaSlotIndex  

sonusStMtaStatOperStat 1.3.6.1.4.1.2879.2.1.3.1.4.1.3
Indicates the operational status of the MTA
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), fault(2), warmupDelay(3), inService(4), outOfService(5), available(6)  

sonusStMtaStatMtaHwDesc 1.3.6.1.4.1.2879.2.1.3.1.4.1.4
Description of the MTA hardware in the form of 'hwtype_hwRev'.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

sonusStMtaStatMtaHwType 1.3.6.1.4.1.2879.2.1.3.1.4.1.5
Description of the MTA hardware Type only. Entry 5+6 obsolete entry 4.
Status: current Access: read-only
OBJECT-TYPE    
  HwTypeID  

sonusStMtaStatMtaHwTypeRev 1.3.6.1.4.1.2879.2.1.3.1.4.1.6
Description of the MTA hardware type revision. Entry 5+6 obsolete entry 4.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusStMtaStatMtaSerialNum 1.3.6.1.4.1.2879.2.1.3.1.4.1.7
Identifies the serial number of the server module. This is the serial number assigned to the mta module in manufacturing.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

sonusStMtaStatMtaPartNum 1.3.6.1.4.1.2879.2.1.3.1.4.1.8
Identifies the part number of the server module. This is the part number assigned to the mta module in manufacturing.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..10)  

sonusStTimingSourceTable 1.3.6.1.4.1.2879.2.1.3.1.5
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStTimingSourceEntry

sonusStTimingSourceEntry 1.3.6.1.4.1.2879.2.1.3.1.5.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStTimingSourceEntry  

sonusStTimingSourceShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.5.1.1
Status: current Access: read-write
OBJECT-TYPE    
  SonusShelfIndex  

sonusStTimingSourceMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.5.1.2
Indicates which MTA this timing node is bound to.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..2  

sonusStTimingSource 1.3.6.1.4.1.2879.2.1.3.1.5.1.3
Indicates which physical timing source is bound to this node. External BITS sources are used by MTA 10's, in T1 based chassis'. External SETS sources are used by MTA 2X's, in E1 based chassis'. REFCLK's are based upon timing recovered from a CNS or PNS Server card. HOLDOVER mimics the last known good source before it failed. OSCILLATOR is used when no other valid sources exist on the currently active MTA.
Status: current Access: read-write
OBJECT-TYPE    
  SonusTimingSource  

sonusStTimingSourceState 1.3.6.1.4.1.2879.2.1.3.1.5.1.4
If enabled, the source can participate in system timing. If disabled, then it will be removed from service and not be allowed to participate.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusStTimingSourceSequenceNum 1.3.6.1.4.1.2879.2.1.3.1.5.1.5
The timing sequence number is automatically generated
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..12  

sonusStTimingSourceAction 1.3.6.1.4.1.2879.2.1.3.1.5.1.6
Selecting AVAILABLE will cause the timing source to be moved from the Out-Of-Service state to the Available-For-Use state. This command is necessary to manually make a source available for use after it has failed, and revertive source switching is not enabled. This may cause the current active timing source to change.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), available(2)  

sonusStTimingSourceRowStatus 1.3.6.1.4.1.2879.2.1.3.1.5.1.7
This object indicates the row status for this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusStTimingSourceStatTable 1.3.6.1.4.1.2879.2.1.3.1.6
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStTimingSourceStatEntry

sonusStTimingSourceStatEntry 1.3.6.1.4.1.2879.2.1.3.1.6.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStTimingSourceStatEntry  

sonusStTimingSourceStatShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.6.1.1
Indicates shelf.
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStTimingSourceStatMtaSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.6.1.2
Indicates which MTA this timing node is bound to.
Status: current Access: read-only
OBJECT-TYPE    
  SonusMtaSlotIndex  

sonusStTimingSourceStat 1.3.6.1.4.1.2879.2.1.3.1.6.1.3
Indicates the physical timing source
Status: current Access: read-only
OBJECT-TYPE    
  SonusTimingSource  

sonusStTimingSourceStatState 1.3.6.1.4.1.2879.2.1.3.1.6.1.4
Indicates the current overall state of the timing source, including the hardware state, adminitrative mode and shelf configuration
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER available(1), inservice(2), faulting(3), outofservice(4), cannotlocate(5), notpresent(6)  

sonusStTimingSourceStatTraceability 1.3.6.1.4.1.2879.2.1.3.1.6.1.5
Indicates the Quality Level of the System Synchronized Timing Source
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER synchronizedunknown(1), stratum1(2), stratum2(3), stratumTNC(4), stratum3e(5), stratum3(6), stratumSonetMinimum(7), stratum4(8), reserved(9), dontUse(10), indeterminate(11), qualityunknown(12), g811(13), g812transit(14), g812local(15), sets(16), g704rsvdql1(17), g704rsvdql3(18), g704rsvdql5(19), g704rsvdql6(20), g704rsvdql7(21), g704rsvdql9(22), g704rsvdql10(23), g704rsvdql12(24), g704rsvdql13(25), g704rsvdql14(26)  

sonusStTimingSourceStatLineState 1.3.6.1.4.1.2879.2.1.3.1.6.1.6
Indicates the current physical status of the timing source
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER valid(1), notvalid(2)  

sonusStChannelBindingTable 1.3.6.1.4.1.2879.2.1.3.1.7
This table describes how derived timing sources should be mapped to the MTA hardware
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusStChannelBindingEntry

sonusStChannelBindingEntry 1.3.6.1.4.1.2879.2.1.3.1.7.1
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusStChannelBindingEntry  

sonusStChannelBindingShelfIndex 1.3.6.1.4.1.2879.2.1.3.1.7.1.1
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusStChannelBindingSlotIndex 1.3.6.1.4.1.2879.2.1.3.1.7.1.2
Server slot number to provide a recovered clock source. The same server can be configured to provide both possible recovered clocks as long as different channels(spans) are selected, and the REFCLK each is bound to differs
Status: current Access: read-only
OBJECT-TYPE    
  SonusSlotIndex  

sonusStChannelBindingChannel 1.3.6.1.4.1.2879.2.1.3.1.7.1.3
T1/E1 span or OC12 port number to provide the recovered clock source. T1 span range is 1-12(CNS10), 1-28(CNS30), E1 span range is 1-8(CNS20), OC12 port number(PNS20) is 1 only.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusStChannelBindingRefClk 1.3.6.1.4.1.2879.2.1.3.1.7.1.4
Backplane signal the recovered clock source should be bound to. Each REFCLK must only be bound to a single Server slot/span.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER refClkA(1), refClkB(2)  

sonusStChannelBindingRowStatus 1.3.6.1.4.1.2879.2.1.3.1.7.1.5
This object indicates the row status for this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusSystemTimingMIBNotifications 1.3.6.1.4.1.2879.2.1.3.2
OBJECT IDENTIFIER    

sonusSystemTimingMIBNotificationsPrefix 1.3.6.1.4.1.2879.2.1.3.2.0
OBJECT IDENTIFIER    

sonusSystemTimingMIBNotificationsObjects 1.3.6.1.4.1.2879.2.1.3.2.1
OBJECT IDENTIFIER    

sonusTimingSource 1.3.6.1.4.1.2879.2.1.3.2.1.1
Status: current Access: read-only
OBJECT-TYPE    
  SonusTimingSource  

sonusTimingSource2 1.3.6.1.4.1.2879.2.1.3.2.1.2
Status: current Access: read-only
OBJECT-TYPE    
  SonusEventString  

sonusSystemTimingActiveFailedNotification 1.3.6.1.4.1.2879.2.1.3.2.0.1
This trap indicates that the currently active System Timing clock source has failed.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSystemTimingActiveSwitchoverNotification 1.3.6.1.4.1.2879.2.1.3.2.0.2
This trap indicates that the active System Timing clock source has been switched to another source.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSystemTimingOscillatorActiveNotification 1.3.6.1.4.1.2879.2.1.3.2.0.3
This trap indicates that all external sources of System Timing have failed and that the current source of timing is the MTA's internal oscillator.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSystemTimingMTAFailedNotification 1.3.6.1.4.1.2879.2.1.3.2.0.4
This trap indicates that the MTA indicated has failed or been removed from the shelf.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSystemTimingMTAOperationalNotification 1.3.6.1.4.1.2879.2.1.3.2.0.6
This trap indicates that the specified MTA is now operational.
Status: current Access: read-only
NOTIFICATION-TYPE    

sonusSystemTimingMTATotalFailureNotification 1.3.6.1.4.1.2879.2.1.3.2.0.7
This trap indicates that no MTA's are available for use to provide System Timing. They have either failed, been removed from service or been removed from the shelf. The shelf is no longer capable of being properly timed. Downstream Shelves or other equipment connected to this shelf's MITDC(Marlin Inter-chassis Timing Daisy Chain) may be affected.
Status: current Access: read-only
NOTIFICATION-TYPE