SONUS-DSP-RESOURCES-MIB

File: SONUS-DSP-RESOURCES-MIB.mib (30996 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SONUS-COMMON-MIB
SONUS-SMI SONUS-TC

Imported symbols

Integer32 MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE RowStatus sonusEventClass
sonusEventDescription sonusEventLevel sonusShelfIndex
sonusResourcesMIBs SonusAdminState SonusName
SonusShelfIndex

Defined Types

SonusDspAdmnEntry  
SEQUENCE    
  sonusDspAdmnShelfIndex Integer32
  sonusDspAdmnSlotIndex Integer32
  sonusDspAdmnDspIndex Integer32
  sonusDspAdmnType INTEGER
  sonusDspAdmnNumChannels Integer32
  sonusDspAdmnMaxTail INTEGER
  sonusDspAdmnEcAudioType INTEGER
  sonusDspAdmnEcSignallingTone INTEGER
  sonusDspAdmnNlpDisable Integer32
  sonusDspAdmnNlpEnable Integer32
  sonusDspAdmnJitterEvalPeriod Integer32
  sonusDspAdmnJitterMinOccThsh Integer32
  sonusDspResidualEchoControl INTEGER
  sonusDspEchoReturnLoss INTEGER
  sonusDspModemDisable INTEGER
  sonusDspHighLevelComp INTEGER

SonusDspSlotStatEntry  
SEQUENCE    
  sonusDspSlotStatShelfIndex Integer32
  sonusDspSlotStatSlotIndex Integer32
  sonusDspSlotStatG711EcTotal Integer32
  sonusDspSlotStatG711Total Integer32
  sonusDspSlotStatHdlcTotal Integer32
  sonusDspSlotStatToneTotal Integer32
  sonusDspSlotStatG729AbTotal Integer32
  sonusDspSlotStatG711EcUtilization Integer32
  sonusDspSlotStatG711EcAllocFailures Integer32
  sonusDspSlotStatG711Utilization Integer32
  sonusDspSlotStatG711AllocFailures Integer32
  sonusDspSlotStatHdlcUtilization Integer32
  sonusDspSlotStatHdlcAllocFailures Integer32
  sonusDspSlotStatToneUtilization Integer32
  sonusDspSlotStatToneAllocFailures Integer32
  sonusDspSlotStatG729AbUtilization Integer32
  sonusDspSlotStatG729AbAllocFailures Integer32

SonusPadAdmnEntry  
SEQUENCE    
  sonusPadAdmnShelfIndex SonusShelfIndex
  sonusPadAdmnJitterEvalPeriod Integer32
  sonusPadAdmnJitterMinOccThsh Integer32
  sonusPadAdmnRtpG711ALaw Integer32
  sonusPadAdmnRtpG711ULaw Integer32
  sonusPadAdmnRtpG729A Integer32
  sonusPadAdmnRtpG729AB Integer32
  sonusPadAdmnG729ABThreshold Integer32
  sonusPadAdmnG729ABThresholdState SonusAdminState
  sonusPadAdmnToneThreshold Integer32
  sonusPadAdmnToneThresholdState SonusAdminState
  sonusPadAdmnRowStatus RowStatus
  sonusPadAdmnRtpDtmfRelay Integer32
  sonusPadAdmnRtpFaxRelay Integer32
  sonusPadAdmnSidMinTime Integer32
  sonusPadAdmnSidMaxTime Integer32
  sonusPadAdmnSidHangoverTime Integer32
  sonusPadAdmnSidMinNoiseFloor Integer32
  sonusPadAdmnSidMaxNoiseFloor Integer32
  sonusPadAdmnComfortEnergy Integer32

SonusEchoCancellorProfileEntry  
SEQUENCE    
  sonusEchoCancellorProfileIndex Integer32
  sonusEchoCancellorProfileName SonusName
  sonusEchoCancellorProfileState SonusAdminState
  sonusEchoCancellorProfileMaxTail INTEGER
  sonusEchoCancellorProfileAudioType INTEGER
  sonusEchoCancellorProfileSignallingTone INTEGER
  sonusEchoCancellorProfileNlpDisable Integer32
  sonusEchoCancellorProfileNlpEnable Integer32
  sonusEchoCancellorProfileReturnLoss INTEGER
  sonusEchoCancellorProfileResidualEcho INTEGER
  sonusEchoCancellorProfileHiLevelComp INTEGER
  sonusEchoCancellorProfileModemDisable INTEGER
  sonusEchoCancellorProfileRowStatus RowStatus
  sonusEchoCancellorProfileNarrowbandDetection INTEGER

Defined Values

sonusDspResourcesMIB 1.3.6.1.4.1.2879.2.2.1
The MIB Module for DSP Resources Management.
MODULE-IDENTITY    

sonusDspResourcesMIBObjects 1.3.6.1.4.1.2879.2.2.1.1
OBJECT IDENTIFIER    

sonusChannelStatTable 1.3.6.1.4.1.2879.2.2.1.1.1
OBJECT IDENTIFIER    

sonusDspAdmnTable 1.3.6.1.4.1.2879.2.2.1.1.2
Table of Sonus Enterprise DSP Admn information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusDspAdmnEntry

sonusDspAdmnEntry 1.3.6.1.4.1.2879.2.2.1.1.2.1
Entry in Table consisting of the all the Sonus DSP ADMN information
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusDspAdmnEntry  

sonusDspAdmnShelfIndex 1.3.6.1.4.1.2879.2.2.1.1.2.1.1
Shelf Index for this table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspAdmnSlotIndex 1.3.6.1.4.1.2879.2.2.1.1.2.1.2
Slot index for this table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspAdmnDspIndex 1.3.6.1.4.1.2879.2.2.1.1.2.1.3
DSP index into this table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspAdmnType 1.3.6.1.4.1.2879.2.2.1.1.2.1.4
DSP Function Type, VPAD XPAD TONE etc.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER vpad(1), hdlc(2), g729AB(3), tone(4)  

sonusDspAdmnNumChannels 1.3.6.1.4.1.2879.2.2.1.1.2.1.5
Number of channels on this DSP
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

sonusDspAdmnMaxTail 1.3.6.1.4.1.2879.2.2.1.1.2.1.6
Maximum Echo tail length
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER millisecs24(1), millisec32(2), millisec48(3), millisec64(4)  

sonusDspAdmnEcAudioType 1.3.6.1.4.1.2879.2.2.1.1.2.1.7
Echo Cancellation: A-law or U-law
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER uLaw(1), aLaw(2)  

sonusDspAdmnEcSignallingTone 1.3.6.1.4.1.2879.2.2.1.1.2.1.8
Echo Cancellation: None, 2400, 2600 or 2101 Hz
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), c5(2)  

sonusDspAdmnNlpDisable 1.3.6.1.4.1.2879.2.2.1.1.2.1.9
Non-linear processing control, Disable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

sonusDspAdmnNlpEnable 1.3.6.1.4.1.2879.2.2.1.1.2.1.10
Non-linear processing control, Enable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..15  

sonusDspAdmnJitterEvalPeriod 1.3.6.1.4.1.2879.2.2.1.1.2.1.11
Time period to decide when to periodically evaluate playout occupancy in units of 1.25 msec = 1 subframe
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..65535  

sonusDspAdmnJitterMinOccThsh 1.3.6.1.4.1.2879.2.2.1.1.2.1.12
If occupancy falls below this threshold for some time period we advance the playout time. Units are 125usec samples
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..65535  

sonusDspResidualEchoControl 1.3.6.1.4.1.2879.2.2.1.1.2.1.13
For Network Echo Cancellation, specifies the residual echo cancellation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cancelOnly(1), suppressResidual(2), comfortNoise(4)  

sonusDspEchoReturnLoss 1.3.6.1.4.1.2879.2.2.1.1.2.1.14
For Network Echo Cancellation, specifies the echo return loss in dB's. Default value is 6dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dB6(1), dB3(2), dB0(3)  

sonusDspModemDisable 1.3.6.1.4.1.2879.2.2.1.1.2.1.15
For Network Echo Cancellation, specifies whether to disable echo cancellation when a modem tone is detected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ignore2100Hz(1), g164(2), g165(4)  

sonusDspHighLevelComp 1.3.6.1.4.1.2879.2.2.1.1.2.1.16
For Network Echo Cancellation, the high level compensation value. Default value is to attenuate by 6dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dB6(2)  

sonusDspStatTable 1.3.6.1.4.1.2879.2.2.1.1.3
OBJECT IDENTIFIER    

sonusDspSlotStatTable 1.3.6.1.4.1.2879.2.2.1.1.4
Table of Sonus Enterprise DSP Resource Status for a particular slot
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusDspSlotStatEntry

sonusDspSlotStatEntry 1.3.6.1.4.1.2879.2.2.1.1.4.1
Entry in Table consisting of Sonus DSP Resource Status information for a particular slot
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusDspSlotStatEntry  

sonusDspSlotStatShelfIndex 1.3.6.1.4.1.2879.2.2.1.1.4.1.1
Shelf index for this table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatSlotIndex 1.3.6.1.4.1.2879.2.2.1.1.4.1.2
Slot index for this table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711EcTotal 1.3.6.1.4.1.2879.2.2.1.1.4.1.3
Total number of G711 with Echo Cancellation resources available on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711Total 1.3.6.1.4.1.2879.2.2.1.1.4.1.4
Total number of G711 resources available on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatHdlcTotal 1.3.6.1.4.1.2879.2.2.1.1.4.1.5
Total number of HDLC resources available on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatToneTotal 1.3.6.1.4.1.2879.2.2.1.1.4.1.6
Total number of Tones resources available on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG729AbTotal 1.3.6.1.4.1.2879.2.2.1.1.4.1.7
Total number of G729A+B resources available on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711EcUtilization 1.3.6.1.4.1.2879.2.2.1.1.4.1.8
Percentage utilization of G711 Echo canceller resources on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711EcAllocFailures 1.3.6.1.4.1.2879.2.2.1.1.4.1.9
Percentage of G711 Echo canceller resources allocation failures on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711Utilization 1.3.6.1.4.1.2879.2.2.1.1.4.1.10
Percentage utilization of G711 resources on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG711AllocFailures 1.3.6.1.4.1.2879.2.2.1.1.4.1.11
Percentage of G711 resources allocation failures on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatHdlcUtilization 1.3.6.1.4.1.2879.2.2.1.1.4.1.12
Percentage utilization HDLC resources on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatHdlcAllocFailures 1.3.6.1.4.1.2879.2.2.1.1.4.1.13
Percentage of HDLC resources allocation failures on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatToneUtilization 1.3.6.1.4.1.2879.2.2.1.1.4.1.14
Percentage utilization of Tone resources on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatToneAllocFailures 1.3.6.1.4.1.2879.2.2.1.1.4.1.15
Percentage of Tone resources allocation failures on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG729AbUtilization 1.3.6.1.4.1.2879.2.2.1.1.4.1.16
Percentage utilization of G729A+B resources on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusDspSlotStatG729AbAllocFailures 1.3.6.1.4.1.2879.2.2.1.1.4.1.17
Percentage of G729A+B resources allocation failures on this slot
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusPadAdmnTable 1.3.6.1.4.1.2879.2.2.1.1.5
Table of Sonus Enterprise Packet Assembler Dis-Assembler Admn information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusPadAdmnEntry

sonusPadAdmnEntry 1.3.6.1.4.1.2879.2.2.1.1.5.1
Entry in Table consisting of the Sonus Packet Assembler Dis-assembler Administartion information
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusPadAdmnEntry  

sonusPadAdmnShelfIndex 1.3.6.1.4.1.2879.2.2.1.1.5.1.1
Shelf Index for Sonus PAD table.
Status: current Access: read-only
OBJECT-TYPE    
  SonusShelfIndex  

sonusPadAdmnJitterEvalPeriod 1.3.6.1.4.1.2879.2.2.1.1.5.1.2
Time period to decide when to periodically evaluate playout occupancy in units of millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 10..300000  

sonusPadAdmnJitterMinOccThsh 1.3.6.1.4.1.2879.2.2.1.1.5.1.3
If occupancy falls below this threshold for some time period we advance the playout time in units of millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2..200  

sonusPadAdmnRtpG711ALaw 1.3.6.1.4.1.2879.2.2.1.1.5.1.4
This Payload type is no longer configurable. It has been standardized in RFC 1890.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnRtpG711ULaw 1.3.6.1.4.1.2879.2.2.1.1.5.1.5
This Payload type is no longer configurable. It has been standardized in RFC 1890.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnRtpG729A 1.3.6.1.4.1.2879.2.2.1.1.5.1.6
This Payload type is no longer configurable. It has been standardized in RFC 1890.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnRtpG729AB 1.3.6.1.4.1.2879.2.2.1.1.5.1.7
This Payload type is no longer configurable. It has been standardized in RFC 1890.
Status: obsolete Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnG729ABThreshold 1.3.6.1.4.1.2879.2.2.1.1.5.1.8
Perecentage Threshold crossing value for G729AB resources. When this threshold is reached an event will be generated if sonusPadAdmnG729ABThresholdState is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

sonusPadAdmnG729ABThresholdState 1.3.6.1.4.1.2879.2.2.1.1.5.1.9
State of G729AB Threshold Event, Enabled/Disabled. An event will be generated only if state is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusPadAdmnToneThreshold 1.3.6.1.4.1.2879.2.2.1.1.5.1.10
Perecentage Threshold crossing value for tone resources. When this threshold is reached an event will be generated if sonusPadAdmnToneThresholdState is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..100  

sonusPadAdmnToneThresholdState 1.3.6.1.4.1.2879.2.2.1.1.5.1.11
State of Tone Threshold Event, Enabled/Disabled. An event will be generated only if state is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusPadAdmnRowStatus 1.3.6.1.4.1.2879.2.2.1.1.5.1.12
This object is used to create, delete, or modify a row in this table.
Status: current Access: read-only
OBJECT-TYPE    
  RowStatus  

sonusPadAdmnRtpDtmfRelay 1.3.6.1.4.1.2879.2.2.1.1.5.1.13
RTP Payload type used for DTMF relay during compressed calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnRtpFaxRelay 1.3.6.1.4.1.2879.2.2.1.1.5.1.14
RTP Payload type used for fax relay during compressed calls.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..127  

sonusPadAdmnSidMinTime 1.3.6.1.4.1.2879.2.2.1.1.5.1.15
Minimum time between silence packets. In units of millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..300000  

sonusPadAdmnSidMaxTime 1.3.6.1.4.1.2879.2.2.1.1.5.1.16
Maximum time between silence packets. Must be larger than minimum time between silence packets. In units of millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 50..300000  

sonusPadAdmnSidHangoverTime 1.3.6.1.4.1.2879.2.2.1.1.5.1.17
Minimum time after a VAD detects speaker going inactive before sending a silence packets. In units of millisecond.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 80..2560  

sonusPadAdmnSidMinNoiseFloor 1.3.6.1.4.1.2879.2.2.1.1.5.1.18
Minimum noise floor, if energy level is below this it will be considered as silence. Configuration range is between -62dBm -24dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 24..62  

sonusPadAdmnSidMaxNoiseFloor 1.3.6.1.4.1.2879.2.2.1.1.5.1.19
Maximum noise floor, if the energy level is above this it will be considered as speech. Configuration range is between -62dBm -24dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 24..62  

sonusPadAdmnComfortEnergy 1.3.6.1.4.1.2879.2.2.1.1.5.1.20
Initial estimate to be used for generating comfort noise. It is used when no silence packets are received to generate comfort noise. Configuration range is between -90dBm and -35dBm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 35..90  

sonusEchoCancellorProfile 1.3.6.1.4.1.2879.2.2.1.1.6
OBJECT IDENTIFIER    

sonusEchoCancellorProfileNextIndex 1.3.6.1.4.1.2879.2.2.1.1.6.1
The next valid index to use when creating an entry in the sonusEchoCancellorProfile.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusEchoCancellorProfileTable 1.3.6.1.4.1.2879.2.2.1.1.6.2
Table of Sonus Enterprise Echo Canceller Profile information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SonusEchoCancellorProfileEntry

sonusEchoCancellorProfileEntry 1.3.6.1.4.1.2879.2.2.1.1.6.2.1
Entry in Table consisting of the Sonus Echo Canceller Profile entries
Status: current Access: not-accessible
OBJECT-TYPE    
  SonusEchoCancellorProfileEntry  

sonusEchoCancellorProfileIndex 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.1
Index into the Echo Canceller Profile table
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

sonusEchoCancellorProfileName 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.2
Name of this Echo Canceller Profile
Status: current Access: read-write
OBJECT-TYPE    
  SonusName  

sonusEchoCancellorProfileState 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.3
Echo Canceller Profile state. Profile can only be applied when in enabled state.
Status: current Access: read-write
OBJECT-TYPE    
  SonusAdminState  

sonusEchoCancellorProfileMaxTail 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.4
Maximum Echo canceller tail length
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER millisec24(1), millisec32(2), millisec48(3), millisec64(4)  

sonusEchoCancellorProfileAudioType 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.5
Audio encoding type A-law or U-law
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER uLaw(1), aLaw(2)  

sonusEchoCancellorProfileSignallingTone 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.6
Echo Cancellation: None, 2400, 2600 or 2101 Hz
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), c5(2)  

sonusEchoCancellorProfileNlpDisable 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.7
Non-linear processing control, Disable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..16  

sonusEchoCancellorProfileNlpEnable 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.8
Non-linear processing control, Enable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..80  

sonusEchoCancellorProfileReturnLoss 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.9
For Network Echo Cancellation, specifies the echo return loss in dB's. Default value is 6dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dB6(1), dB3(2), dB0(3)  

sonusEchoCancellorProfileResidualEcho 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.10
For Network Echo Cancellation, specifies the residual echo cancellation.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER cancelOnly(1), suppressResidual(2), comfortNoise(4)  

sonusEchoCancellorProfileHiLevelComp 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.11
For Network Echo Cancellation, the high level compensation value. Default value is to attenuate by 6dB.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), dB6(2)  

sonusEchoCancellorProfileModemDisable 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.12
For Network Echo Cancellation, specifies whether to disable echo cancellation when a modem tone is detected.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ignore2100Hz(1), g164(2), g165(4)  

sonusEchoCancellorProfileRowStatus 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.13
This object is used to create, delete, or modify a row in this table.
Status: current Access: read-write
OBJECT-TYPE    
  RowStatus  

sonusEchoCancellorProfileNarrowbandDetection 1.3.6.1.4.1.2879.2.2.1.1.6.2.1.14
For Network Echo Cancellation, narrow band detection is OFF or ON. If set ON it narrows the G.164 detection bandwidth in G.165 mode to the G.165 band.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

sonusPadMIBNotifications 1.3.6.1.4.1.2879.2.2.1.2
OBJECT IDENTIFIER    

sonusPadMIBNotificationsPrefix 1.3.6.1.4.1.2879.2.2.1.2.0
OBJECT IDENTIFIER    

sonusPadMIBNotificationsObjects 1.3.6.1.4.1.2879.2.2.1.2.1
OBJECT IDENTIFIER    

sonusPadThresholdType 1.3.6.1.4.1.2879.2.2.1.2.1.1
Type of resource usage that caused a threshold crossing trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER g729AB(1), tone(2)  

sonusPadThresholdState 1.3.6.1.4.1.2879.2.2.1.2.1.2
State of threshold, indicates whether threshold is on or off
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER off(1), on(2)  

sonusPadThresholdNotification 1.3.6.1.4.1.2879.2.2.1.2.0.1
Generated when a PAD resource usage has gone above the threshold value. The type indicates the type reseource.
Status: current Access: read-only
NOTIFICATION-TYPE