SNMPv2-M2M-MIB
File:
SNMPv2-M2M-MIB.mib (32285 bytes)
Imported modules
Imported symbols
Defined Types
SnmpAlarmEntry |
|
SEQUENCE |
|
|
|
|
snmpAlarmIndex |
INTEGER |
|
|
snmpAlarmVariable |
InstancePointer |
|
|
snmpAlarmInterval |
Integer32 |
|
|
snmpAlarmSampleType |
INTEGER |
|
|
snmpAlarmValue |
Integer32 |
|
|
snmpAlarmStartupAlarm |
INTEGER |
|
|
snmpAlarmRisingThreshold |
Integer32 |
|
|
snmpAlarmFallingThreshold |
Integer32 |
|
|
snmpAlarmRisingEventIndex |
INTEGER |
|
|
snmpAlarmFallingEventIndex |
INTEGER |
|
|
snmpAlarmUnavailableEventIndex |
INTEGER |
|
|
snmpAlarmStatus |
RowStatus |
|
SnmpEventEntry |
|
SEQUENCE |
|
|
|
|
snmpEventIndex |
INTEGER |
|
|
snmpEventID |
OBJECT IDENTIFIER |
|
|
snmpEventDescription |
DisplayString |
|
|
snmpEventEvents |
Counter32 |
|
|
snmpEventLastTimeSent |
TimeStamp |
|
|
snmpEventStatus |
RowStatus |
|
SnmpEventNotifyEntry |
|
SEQUENCE |
|
|
|
|
snmpEventNotifyIntervalRequested |
Integer32 |
|
|
snmpEventNotifyRetransmissionsRequested |
Integer32 |
|
|
snmpEventNotifyLifetime |
Integer32 |
|
|
snmpEventNotifyStatus |
RowStatus |
|
Defined Values
snmpM2M |
1.3.6.1.6.3.2 |
The Manager-to-Manager MIB module. |
MODULE-IDENTITY |
|
|
|
snmpAlarm |
1.3.6.1.6.3.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
snmpAlarmNextIndex |
1.3.6.1.6.3.2.1.1.1 |
The index number of the next appropriate
unassigned entry in the snmpAlarmTable. The value
0 indicates that no unassigned entries are
available.
A management station should create new entries in
the snmpAlarmTable using this algorithm: first,
issue a management protocol retrieval operation to
determine the value of snmpAlarmNextIndex; and,
second, issue a management protocol set operation
to create an instance of the snmpAlarmStatus
object setting its value to `createAndGo' or
`createAndWait' (as specified in the description
of the RowStatus textual convention). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
snmpAlarmTable |
1.3.6.1.6.3.2.1.1.2 |
A list of snmpAlarm entries. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnmpAlarmEntry |
|
snmpAlarmEntry |
1.3.6.1.6.3.2.1.1.2.1 |
A list of parameters that set up a periodic
sampling query to check for alarm conditions. The
contextIdentity included in the INDEX clause is
the context to which the sampling queries are
directed. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnmpAlarmEntry |
|
|
snmpAlarmIndex |
1.3.6.1.6.3.2.1.1.2.1.1 |
An index that uniquely identifies an entry in the
snmpAlarm table for a particular sampling context.
Each such entry defines a diagnostic sample at a
particular interval for a variable in the
particular context's object resources. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
snmpAlarmVariable |
1.3.6.1.6.3.2.1.1.2.1.2 |
The object identifier of the particular variable
to be sampled. Only variables that resolve to an
ASN.1 primitive type of INTEGER (Integer32,
Counter32, Gauge32, TimeTicks, Counter64, or
UInteger32) may be sampled.
If it is detected by an error response of
authorizationError, noSuchObject, or
noSuchInstance that the variable name of an
established snmpAlarmEntry is no longer available
in the sampling context, a single
snmpObjectUnavailableAlarm event is generated and
the status of this snmpAlarmEntry is set to
`destroy'. Likewise, if the syntax of the
variable retrieved by the query is not Integer32,
Counter32, Gauge32, TimeTicks, Counter64, or
UInteger32, the same actions will be taken.
If the SNMPv2 entity acting in a dual role detects
that the sampled value can not be obtained due to
lack of response to management queries, it should
either:
1) Set the status of this snmpAlarmEntry to
`destroy', if it is determined that further
communication is not possible;
or,
2) Delete the associated snmpAlarmValue
instance (but not the entire conceptual row),
and continue to attempt to sample the
variable and recreate the associated
snmpAlarmValue instance should communication
be reestablished.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
InstancePointer |
|
|
snmpAlarmInterval |
1.3.6.1.6.3.2.1.1.2.1.3 |
The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this object and the
sampling type is `deltaValue', care should be
taken to ensure that the change during this
interval of the variable being sampled will not
exceed the (-2^31...2^31-1) range of the
snmpAlarmValue.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpAlarmSampleType |
1.3.6.1.6.3.2.1.1.2.1.4 |
The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
`absoluteValue', the value of the selected
variable at the end of the sampling interval will
be compared directly with both the
snmpAlarmRisingThreshold and the
snmpAlarmFallingThreshold values. If the value of
this object is `deltaValue', the value of the
selected variable at the end of the sampling
interval will be subtracted from its value at the
end of the previous sampling interval, and the
difference compared with both the
snmpAlarmRisingThreshold and the
snmpAlarmFallingThreshold values.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
absoluteValue(1), deltaValue(2) |
|
snmpAlarmValue |
1.3.6.1.6.3.2.1.1.2.1.5 |
The value of the statistic during the last
sampling period. The value during the current
sampling period is not made available until the
period is completed. If the value of the
statistic does not fit in the signed 32 bit
representation of this object, it should be
truncated in an implementation specific manner.
Note that if the associated snmpAlarmSampleType is
set to `deltaValue', the value of this object is
the difference in the sampled variable since the
last sample.
This object will be created by the SNMPv2 entity
acting in a dual role when this entry is set to
`active', and the first sampling period has
completed. It may be created and deleted at other
times by the SNMPv2 entity acting in a dual role
when the sampled value can not be obtained, as
specified in the snmpAlarmVariable object. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpAlarmStartupAlarm |
1.3.6.1.6.3.2.1.1.2.1.6 |
The alarm that may be sent when this entry is
first set to `active'. If the first sample after
this entry becomes active is greater than or equal
to the risingThreshold and snmpAlarmStartupAlarm
is equal to `risingAlarm' or
`risingOrFallingAlarm', then a single rising alarm
will be generated. If the first sample after this
entry becomes active is less than or equal to the
fallingThreshold and snmpAlarmStartupAlarm is
equal to `fallingAlarm' or `risingOrFallingAlarm',
then a single falling alarm will be generated.
Note that a snmpObjectUnavailableAlarm is sent
upon startup whenever it is applicable,
independent of the setting of
snmpAlarmStartupAlarm.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
risingAlarm(1), fallingAlarm(2), risingOrFallingAlarm(3) |
|
snmpAlarmRisingThreshold |
1.3.6.1.6.3.2.1.1.2.1.7 |
A threshold for the sampled statistic. When the
current sampled value is greater than or equal to
this threshold, and the value at the last sampling
interval was less than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes active is greater than or equal to this
threshold and the associated snmpAlarmStartupAlarm
is equal to `risingAlarm' or
`risingOrFallingAlarm'.
After a rising event is generated, another such
event will not be generated until the sampled
value falls below this threshold and reaches the
snmpAlarmFallingThreshold.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpAlarmFallingThreshold |
1.3.6.1.6.3.2.1.1.2.1.8 |
A threshold for the sampled statistic. When the
current sampled value is less than or equal to
this threshold, and the value at the last sampling
interval was greater than this threshold, a single
event will be generated. A single event will also
be generated if the first sample after this entry
becomes active is less than or equal to this
threshold and the associated snmpAlarmStartupAlarm
is equal to `fallingAlarm' or
`risingOrFallingAlarm'.
After a falling event is generated, another such
event will not be generated until the sampled
value rises above this threshold and reaches the
snmpAlarmRisingThreshold.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpAlarmRisingEventIndex |
1.3.6.1.6.3.2.1.1.2.1.9 |
The index of the snmpEventEntry that is used when
a rising threshold is crossed. The snmpEventEntry
identified by a particular value of this index is
the same as identified by the same value of the
snmpEventIndex object. If there is no
corresponding entry in the snmpEventTable, then no
association exists. In particular, if this value
is zero, no associated event will be generated, as
zero is not a valid snmpEventIndex.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
snmpAlarmFallingEventIndex |
1.3.6.1.6.3.2.1.1.2.1.10 |
The index of the snmpEventEntry that is used when
a falling threshold is crossed. The
snmpEventEntry identified by a particular value of
this index is the same as identified by the same
value of the snmpEventIndex object. If there is
no corresponding entry in the snmpEventTable, then
no association exists. In particular, if this
value is zero, no associated event will be
generated, as zero is not a valid snmpEventIndex.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
snmpAlarmUnavailableEventIndex |
1.3.6.1.6.3.2.1.1.2.1.11 |
The index of the snmpEventEntry that is used when
a variable becomes unavailable. The
snmpEventEntry identified by a particular value of
this index is the same as identified by the same
value of the snmpEventIndex object. If there is
no corresponding entry in the snmpEventTable, then
no association exists. In particular, if this
value is zero, no associated event will be
generated, as zero is not a valid snmpEventIndex.
An attempt to modify this object will fail with an
`inconsistentValue' error if the associated
snmpAlarmStatus object would be equal to `active'
both before and after the modification attempt. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
snmpAlarmStatus |
1.3.6.1.6.3.2.1.1.2.1.12 |
The status of this snmpAlarm entry. This object
may not be set to `active' unless the following
columnar objects exist in this row:
snmpAlarmVariable, snmpAlarmInterval,
snmpAlarmSampleType, snmpAlarmStartupAlarm,
snmpAlarmRisingThreshold,
snmpAlarmFallingThreshold,
snmpAlarmRisingEventIndex,
snmpAlarmFallingEventIndex, and
snmpAlarmUnavailableEventIndex. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
snmpRisingAlarm |
1.3.6.1.6.3.2.1.1.3.1 |
An event that is generated when an alarm entry
crosses its rising threshold. The instances of
those objects contained within the varbind list
are those of the alarm entry which generated this
event. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
snmpFallingAlarm |
1.3.6.1.6.3.2.1.1.3.2 |
An event that is generated when an alarm entry
crosses its falling threshold. The instances of
those objects contained within the varbind list
are those of the alarm entry which generated this
event. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
snmpObjectUnavailableAlarm |
1.3.6.1.6.3.2.1.1.3.3 |
An event that is generated when a variable
monitored by an alarm entry becomes unavailable.
The instance of snmpAlarmVariable contained within
the varbind list is the one associated with the
alarm entry which generated this event. |
Status: current |
Access: read-create |
NOTIFICATION-TYPE |
|
|
|
snmpEvent |
1.3.6.1.6.3.2.1.2 |
OBJECT IDENTIFIER |
|
|
|
snmpEventNextIndex |
1.3.6.1.6.3.2.1.2.1 |
The index number of the next appropriate
unassigned entry in the snmpEventTable. The value
0 indicates that no unassigned entries are
available.
A management station should create new entries in
the snmpEventTable using this algorithm: first,
issue a management protocol retrieval operation to
determine the value of snmpEventNextIndex; and,
second, issue a management protocol set operation
to create an instance of the snmpEventStatus
object setting its value to `createAndWait' or
'createAndGo'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
snmpEventEntry |
1.3.6.1.6.3.2.1.2.2.1 |
A set of parameters that describe an event that
is generated when certain conditions are met. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnmpEventEntry |
|
|
snmpEventIndex |
1.3.6.1.6.3.2.1.2.2.1.1 |
An index that uniquely identifies an entry in the
snmpEvent table. Each such entry defines an event
generated when the appropriate conditions occur. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
snmpEventID |
1.3.6.1.6.3.2.1.2.2.1.2 |
The authoritative identification of the event
type generated by this entry. This variable
occurs as the second varbind of an InformRequest-
PDU. If this OBJECT IDENTIFIER maps to a
NOTIFICATION-TYPE the sender will place the
objects listed in the NOTIFICATION-TYPE in the
varbind list. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
snmpEventEvents |
1.3.6.1.6.3.2.1.2.2.1.4 |
The number of events caused by event generators
associated with this snmpEvent entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
snmpEventLastTimeSent |
1.3.6.1.6.3.2.1.2.2.1.5 |
The value of sysUpTime at the time this snmpEvent
entry last generated an event. If this entry has
not generated any events, this value will be
zero. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeStamp |
|
|
snmpEventStatus |
1.3.6.1.6.3.2.1.2.2.1.6 |
The status of this snmpEvent entry. This object
may not be set to `active' unless the following
columnar objects exist in this row: snmpEventID,
snmpEventDescription, snmpEventEvents, and
snmpEventLastTimeSent.
Setting an instance of this object to the value
'destroy' has the effect of invalidating any/all
entries in the snmpEventTable, and the
snmpEventNotifyTable which reference the
corresponding snmpEventEntry. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
snmpEventNotifyMinInterval |
1.3.6.1.6.3.2.1.2.3 |
The minimum interval that the SNMPv2 entity
acting in a dual role will wait before
retransmitting an InformRequest-PDU. This object
specifies the minimal value supported by the
SNMPv2 entity acting in a dual role, based on
resource or implementation constraints.
For a particular entry in the
snmpEventNotifyTable, if the associated
snmpEventNotifyIntervalRequested variable is
greater than this object, the
snmpEventNotifyIntervalRequested value shall be
used as the minimum interval for retransmissions
of InformRequest-PDUs sent on behalf of that
entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpEventNotifyMaxRetransmissions |
1.3.6.1.6.3.2.1.2.4 |
The maximum number of time that the SNMPv2 entity
acting in a dual role will retransmit an
InformRequest-PDU. This object specifies the
maximal value supported by the SNMPv2 entity
acting in a dual role, based on resource or
implementation constraints.
For a particular entry in the
snmpEventNotifyTable, if the associated
snmpEventNotifyRetransmissionsRequested variable
is less than this object, the
snmpEventNotifyRetransmissionsRequested value
shall be used as the retransmission count for
InformRequest-PDUs sent on behalf of that entry. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpEventNotifyTable |
1.3.6.1.6.3.2.1.2.5 |
A list of protocol configuration entries for
event notifications from this entity. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnmpEventNotifyEntry |
|
snmpEventNotifyEntry |
1.3.6.1.6.3.2.1.2.5.1 |
A set of parameters that describe the type and
destination of InformRequest-PDUs sent for a
particular event. The snmpEventIndex in this
entry's INDEX clause identifies the snmpEventEntry
which, when triggered, will generate a
notification as configured in this entry. The
contextIdentity in this entry's INDEX clause
identifies the context to which a notification
will be sent. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnmpEventNotifyEntry |
|
|
snmpEventNotifyIntervalRequested |
1.3.6.1.6.3.2.1.2.5.1.1 |
The requested interval for retransmission of
Inform PDUs generated on the behalf of this entry.
This variable will be the actual interval used
unless the snmpEventNotifyMinInterval is greater
than this object, in which case the interval shall
be equal to snmpEventNotifyMinInterval. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpEventNotifyRetransmissionsRequested |
1.3.6.1.6.3.2.1.2.5.1.2 |
The requested number of retransmissions of an
InformRequest-PDU generated on behalf of this
entry.
This variable will be the actual number of
retransmissions used unless the
snmpEventNotifyMaxRetransmissions is less than
this object, in which case the retransmission
count shall be equal to
snmpEventNotifyMaxRetransmissions. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpEventNotifyLifetime |
1.3.6.1.6.3.2.1.2.5.1.3 |
The number of seconds this entry shall live until
the corresponding instance of
snmpEventNotifyStatus is set to 'destroy'. This
value shall count down to zero, at which time the
corresponding instance of snmpEventNotifyStatus
will be set to 'destroy'. Any management station
that is using this entry must periodically refresh
this value to ensure the continued delivery of
events. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
snmpEventNotifyStatus |
1.3.6.1.6.3.2.1.2.5.1.4 |
The state of this snmpEventNotifyEntry. This
object may not be set to `active' unless the
following columnar objects exist in this row:
snmpEventNotifyIntervalRequested,
snmpEventNotifyRetransmissionsRequested, and
snmpEventNotifyLifetime. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
snmpM2MCompliance |
1.3.6.1.6.3.2.2.1.1 |
The compliance statement for SNMPv2 entities
which implement the Manager-to-Manager MIB. |
Status: current |
Access: read-create |
MODULE-COMPLIANCE |
|
|
|
snmpAlarmGroup |
1.3.6.1.6.3.2.2.2.1 |
A collection of objects allowing the description
and configuration of threshold alarms from a
SNMPv2 entity acting in a dual role. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|
snmpEventGroup |
1.3.6.1.6.3.2.2.2.2 |
A collection of objects allowing the description
and configuration of events from a SNMPv2 entity
acting in a dual role. |
Status: current |
Access: read-create |
OBJECT-GROUP |
|
|
|